Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23.703
Filter
2.
J Cardiovasc Med (Hagerstown) ; 25(7): 529-538, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38829939

ABSTRACT

AIMS: This study assessed the outcomes of concomitant mitral valve disease and severe aortic stenosis in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Echocardiographic data of 813 patients with severe aortic stenosis undergoing transfemoral TAVR were collected, and clinical outcomes were analyzed for individuals with mitral stenosis and mitral regurgitation. RESULTS: The final cohort includes 788 patients with severe calcific aortic stenosis. Among single parameters of mitral stenosis, a smaller baseline mitral valve area (MVA) by the continuity equation and higher postprocedural mean mitral gradients (MMG) were associated with an increased risk of death at 1 year (P-values 0.02 and <0.01, respectively), but no correlation with outcomes was demonstrated after multivariate adjustment for major prognosticators. Mitral stenosis (based on MVA + MMG) was not associated with complications or mortality. Mitral regurgitation was present in 94.6% of the population at baseline and regressed by at least one grade post-TAVR in 28% of the patients. The improvement in mitral regurgitation was associated with a greater prosthetic effective orifice area (P-value 0.03). Significant (at least moderate) residual mitral regurgitation was correlated with short-term complications and shown to be an independent predictor of 1-year mortality (P-value 0.02, odds ratio (OR) 5.37, confidence interval 1.34-21.5). CONCLUSION: Mitral regurgitation has a greater impact on TAVR patients than mitral stenosis as assessed by functional methods.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Mitral Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/mortality , Mitral Valve Stenosis/physiopathology , Mitral Valve Stenosis/complications , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/complications , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aged , Treatment Outcome , Severity of Illness Index , Retrospective Studies , Prognosis , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Calcinosis/mortality , Calcinosis/diagnostic imaging , Calcinosis/complications , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Echocardiography
3.
Sci Rep ; 14(1): 10409, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710782

ABSTRACT

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Transcatheter Aortic Valve Replacement/methods , Humans , Male , Female , Aged, 80 and over , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Aorta/diagnostic imaging , Aorta/surgery , Treatment Outcome , Heart Valve Prosthesis , Retrospective Studies
4.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722121

ABSTRACT

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Subject(s)
Aortic Valve , Echocardiography, Transesophageal , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
5.
Clin Interv Aging ; 19: 695-703, 2024.
Article in English | MEDLINE | ID: mdl-38711477

ABSTRACT

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Postoperative Complications , Propensity Score , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aged , Bicuspid Aortic Valve Disease/surgery , Aged, 80 and over , Postoperative Complications/epidemiology , Retrospective Studies , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/abnormalities , Middle Aged , Risk Factors , Heart Valve Diseases/surgery
6.
Scand Cardiovasc J ; 58(1): 2353070, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38757904

ABSTRACT

Objectives: The role of diabetes mellitus as a risk factor for the development of calcific aortic valve disease has not been fully clarified. Aortic valve interstitial cells (VICs) have been suggested to be crucial for calcification of the valve. Induced calcification in cultured VICs is a good in vitro model for aortic valve calcification. The purpose of this study was to investigate whether increased glucose levels increase experimentally induced calcification in cultured human VICs. Design: VICs were isolated from explanted calcified aortic valves after valve replacement. Osteogenic medium induced calcification of cultured VICs at different glucose levels (5, 15, and 25 mM). Calcium deposits were visualized using Alizarin Red staining and measured spectrophotometrically. Results: The higher the glucose concentration, the lower the level of calcification. High glucose (25 mM) reduced calcification by 52% compared with calcification at a physiological (5 mM) glucose concentration (correlation and regression analysis: r = -0.55, p = .025 with increased concentration of glucose). Conclusions: In vitro hyperglycemia-like conditions attenuated calcification in VICs. High glucose levels may trigger a series of events that secondarily stimulate calcification of VICs in vivo.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Glucose , Hyperglycemia , Humans , Aortic Valve/pathology , Aortic Valve/metabolism , Aortic Valve/surgery , Calcinosis/pathology , Calcinosis/metabolism , Cells, Cultured , Glucose/metabolism , Hyperglycemia/metabolism , Aortic Valve Stenosis/pathology , Aortic Valve Stenosis/metabolism , Aortic Valve Stenosis/surgery , Male , Middle Aged , Aged , Female , Dose-Response Relationship, Drug , Osteogenesis/drug effects
7.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38710669

ABSTRACT

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
8.
Trials ; 25(1): 324, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755709

ABSTRACT

BACKGROUND: The optimal antithrombotic strategy early after aortic valve replacement surgery with a biological valve remains controversial due to lack of high-quality evidence. Either oral anticoagulants or acetylsalicylic acid should be considered for the first 3 months. Hypo-attenuated leaflet thickening on cardiac computed tomography has been associated with latent bioprosthetic valve thrombosis and may be prevented with anticoagulation. We hypothesize that anticoagulation with apixaban is superior to single antiplatelet therapy with acetylsalicylic acid in reducing hypo-attenuated leaflet thickening of bioprosthetic aortic valve prostheses. METHODS: In this prospective, open-label, randomized trial, patients undergoing isolated aortic valve replacement surgery with rapid deployment bioprosthetic valves will be randomized. The treatment group will receive 5 mg of apixaban twice a day for the first 3 months and 100 mg of acetylsalicylic acid thereafter. The control group will be administered 100 mg of acetylsalicylic acid once a day, indefinitely. After the 3-month treatment period, a contrast-enhanced electrocardiogram-gated cardiac computed tomography will be performed to identify hypo-attenuated leaflet thickening of the bioprosthetic valve. The primary objective of the study is to assess the impact of apixaban on the prevention of hypo-attenuated leaflet thickening at 3 months. The secondary and exploratory endpoints will be clinical outcomes and safety profiles of the two strategies. DISCUSSION: Antithrombotic therapy after aortic valve replacement is used to prevent valve thrombosis and systemic thromboembolism. Latent bioprosthetic valve thrombosis is a precursor of clinically significant prosthetic valve dysfunction or thromboembolic events. The hallmark feature of latent bioprosthetic valve thrombosis is hypo-attenuated leaflet thickening on cardiac computed tomography. Subclinical leaflet thrombosis occurs frequently in bioprosthetic aortic valves, more commonly in transcatheter than in surgical valves. There is no evidence on the effect of direct oral anticoagulants on the incidence of hypo-attenuated leaflet thickening after surgical aortic valve replacement with rapid deployment bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov NCT06184113. Registered on December 28, 2023.


Subject(s)
Aortic Valve , Aspirin , Bioprosthesis , Factor Xa Inhibitors , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pyrazoles , Pyridones , Randomized Controlled Trials as Topic , Thrombosis , Humans , Aspirin/administration & dosage , Aspirin/therapeutic use , Aspirin/adverse effects , Pyridones/therapeutic use , Pyridones/administration & dosage , Pyridones/adverse effects , Prospective Studies , Heart Valve Prosthesis/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Thrombosis/prevention & control , Thrombosis/etiology , Pyrazoles/therapeutic use , Pyrazoles/administration & dosage , Pyrazoles/adverse effects , Factor Xa Inhibitors/administration & dosage , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/therapeutic use , Platelet Aggregation Inhibitors/adverse effects , Female , Male , Middle Aged , Time Factors , Aged , Adult , Fibrinolytic Agents/administration & dosage , Fibrinolytic Agents/adverse effects
9.
BMC Cardiovasc Disord ; 24(1): 253, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38750455

ABSTRACT

BACKGROUND: Primary coronary slow flow (CSF) is defined as delayed opacification of the distal epicardial vasculature during coronary angiography in the absence of relevant coronary artery stenoses. Microvascular disease is thought to be the underlying cause of this pathology. Epicardial fat tissue (EFT) is an active endocrine organ directly surrounding the coronary arteries that provides pro-inflammatory factors to the adjacent tissue by paracrine and vasocrine mechanisms. The aim of the present study was to investigate a potential association between EFT and primary CSF and whether EFT can predict the presence of primary CSF. METHODS: Between 2016 and 2017, n = 88 patients with high-grade aortic stenosis who were planned for transcatheter aortic valve implantation (TAVI) were included in this retrospective study. EFT volume was measured by pre-TAVI computed tomography (CT) using dedicated software. The presence of primary CSF was defined based on the TIMI frame count from the pre-TAVI coronary angiograms. RESULTS: Thirty-nine of 88 TAVI patients had CSF (44.3%). EFT volume was markedly higher in patients with CSF (142 ml [IQR 107-180] vs. 113 ml [IQR 89-147]; p = 0.009) and was strongly associated with the presence of CSF (OR 1.012 [95%CI 1.002-1.021]; p = 0.014). After adjustment, EFT volume was still an independent predictor of CSF (OR 1.016 [95%CI 1.004-1.026]; p = 0.009). CONCLUSION: Primary CSF was independently associated with increased EFT volume. Further studies are needed to validate this finding and elucidate whether a causal relationship exists.


Subject(s)
Adipose Tissue , Aortic Valve Stenosis , Coronary Angiography , Coronary Circulation , Pericardium , Predictive Value of Tests , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Female , Male , Retrospective Studies , Pericardium/diagnostic imaging , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Adipose Tissue/diagnostic imaging , Adipose Tissue/physiopathology , Aged, 80 and over , Risk Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Computed Tomography Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Epicardial Adipose Tissue
10.
Sci Rep ; 14(1): 11762, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38783030

ABSTRACT

There is limited data on the effect of socioeconomic status (SES) on transcatheter (TAVR) and surgical aortic valve replacement (SAVR) outcomes for aortic stenosis (AS). This study conducted a population-based analysis to assess the influence of SES on valve replacement outcomes. Patients with AS undergoing TAVR or SAVR were identified in National Inpatient Sample from Q4 2015-2020. Multivariable logistic regressions were used to compare in-hospital outcomes between patients living in neighborhoods of income at the lowest and highest quartiles. Of 613,785 AS patients, 9.77% underwent TAVR and 10.13% had SAVR. These rates decline with lower neighborhood income levels, with TAVR/SAVR ratio also declining in lower-income areas. Excluding concomitant procedures, 58,064 patients received isolated TAVR (12,355 low-income and 15,212 high-income) and 43,694 underwent isolated SAVR (10,029 low-income and 10,811 high-income). Low-income patients, in both TAVR and SAVR, were younger but had more comorbid burden. For isolated TAVR, outcomes were similar across income groups. However, for isolated SAVR, low-income patients experienced higher in-hospital mortality (aOR = 1.44, p < 0.01), pulmonary (aOR = 1.13, p = 0.01), and renal complications (aOR = 1.14, p < 0.01). They also had more transfers, longer waits for operations, and extended hospital stays. Lower-income communities had reduced access to TAVR and SAVR, with TAVR accessibility being particularly limited. When given access to TAVR, patients from lower-income neighborhoods had mostly comparable outcomes. However, patients from low-income communities faced worse outcomes in SAVR, possibly due to delays in treatment. Ensuring equitable specialized healthcare resources including expanding TAVR access in economically disadvantaged communities is crucial.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Aged , Aortic Valve Stenosis/surgery , Aged, 80 and over , Healthcare Disparities , Inpatients/statistics & numerical data , Heart Valve Prosthesis Implantation , United States/epidemiology , Hospital Mortality , Middle Aged , Socioeconomic Factors , Social Class , Aortic Valve/surgery , Treatment Outcome , Socioeconomic Disparities in Health
11.
Open Heart ; 11(1)2024 May 20.
Article in English | MEDLINE | ID: mdl-38769066

ABSTRACT

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Ventricular Function, Left , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Female , Male , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Ventricular Function, Left/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Time Factors , Severity of Illness Index , Follow-Up Studies , Risk Factors , Echocardiography/methods , Aged, 80 and over , Survival Rate/trends , Risk Assessment/methods , Stroke Volume/physiology
12.
J Am Heart Assoc ; 13(10): e034401, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38761080

ABSTRACT

BACKGROUND: Coronary pressure indices to assess coronary artery disease are currently underused in patients with aortic stenosis due to many potential physiological effects that might hinder their interpretation. Studies with varying sample sizes have provided us with conflicting results on the effect of transcatheter aortic valve replacement (TAVR) on these indices. The aim of this meta-analysis was to study immediate and long-term effects of TAVR on fractional flow reserve (FFR) and nonhyperemic pressure ratios (NHPRs). METHODS AND RESULTS: Lesion-specific coronary pressure data were extracted from 6 studies, resulting in 147 lesions for immediate change in FFR analysis and 105 for NHPR analysis. To investigate the long-term changes, 93 lesions for FFR analysis and 68 for NHPR analysis were found. Lesion data were pooled and compared with paired t tests. Immediately after TAVR, FFR decreased significantly (-0.0130±0.0406 SD, P: 0.0002) while NHPR remained stable (0.0003±0.0675, P: 0.9675). Long-term after TAVR, FFR decreased significantly (-0.0230±0.0747, P: 0.0038) while NHPR increased nonsignificantly (0.0166±0.0699, P: 0.0543). When only borderline NHPR lesions were considered, this increase became significant (0.0249±0.0441, P: 0.0015). Sensitivity analysis confirmed our results in borderline lesions. CONCLUSIONS: TAVR resulted in small significant, but opposite, changes in FFR and NHPR. Using the standard cut-offs in patients with severe aortic stenosis, FFR might underestimate the physiological significance of a coronary lesion while NHPRs might overestimate its significance. The described changes only play a clinically relevant role in borderline lesions. Therefore, even in patients with aortic stenosis, an overtly positive or negative physiological assessment can be trusted.


Subject(s)
Aortic Valve Stenosis , Fractional Flow Reserve, Myocardial , Hyperemia , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Coronary Artery Disease/physiopathology , Coronary Artery Disease/surgery , Coronary Artery Disease/diagnosis , Coronary Artery Disease/complications , Coronary Vessels/physiopathology , Fractional Flow Reserve, Myocardial/physiology , Hyperemia/physiopathology , Treatment Outcome
13.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726714

ABSTRACT

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
14.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726720

ABSTRACT

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Subject(s)
Consensus , Hemorrhage , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Hemorrhage/etiology , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
15.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722122

ABSTRACT

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Monitoring, Intraoperative , Child , Humans , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography, Transesophageal/methods , Monitoring, Intraoperative/methods
16.
Sci Rep ; 14(1): 10902, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38740898

ABSTRACT

Calcification of the aortic valve (CAVDS) is a major cause of aortic stenosis (AS) leading to loss of valve function which requires the substitution by surgical aortic valve replacement (SAVR) or transcatheter aortic valve intervention (TAVI). These procedures are associated with high post-intervention mortality, then the corresponding risk assessment is relevant from a clinical standpoint. This study compares the traditional Cox Proportional Hazard (CPH) against Machine Learning (ML) based methods, such as Deep Learning Survival (DeepSurv) and Random Survival Forest (RSF), to identify variables able to estimate the risk of death one year after the intervention, in patients undergoing either to SAVR or TAVI. We found that with all three approaches the combination of six variables, named albumin, age, BMI, glucose, hypertension, and clonal hemopoiesis of indeterminate potential (CHIP), allows for predicting mortality with a c-index of approximately 80 % . Importantly, we found that the ML models have a better prediction capability, making them as effective for statistical analysis in medicine as most state-of-the-art approaches, with the additional advantage that they may expose non-linear relationships. This study aims to improve the early identification of patients at higher risk of death, who could then benefit from a more appropriate therapeutic intervention.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Deep Learning , Humans , Aortic Valve/surgery , Aortic Valve/pathology , Calcinosis/surgery , Calcinosis/mortality , Female , Male , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Survival Analysis , Risk Factors , Proportional Hazards Models , Risk Assessment/methods , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/methods , Middle Aged
17.
J Cardiothorac Surg ; 19(1): 301, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38812010

ABSTRACT

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital anomaly characterized by the presence of four cusps instead of the usual three. It is estimated to occur in less than 0.05% of the population, with Type A (four equal-sized leaflets) accounting for roughly 30% of QAV subtypes. Based on limited clinical series, the usual presentation is progressive aortic valve regurgitation (AR) with symptoms occurring in the fourth to sixth decade of life. Severe aortic valve stenosis (AS) and acute AR are very uncommon. CASE PRESENTATION: We describe two cases of Type A QAV in patients who remained asymptomatic until their seventies with very uncommon presentations: one with severe AS and one with acute, severe AR and flail leaflet. In Case A, a 72-year-old patient with history of moderate AS presents to clinic with progressive exertional dyspnea. During work-up for transcatheter vs. surgical replacement pre-operative computed tomography angiogram (CTA) reveals a quadricuspid aortic valve with severe AS, and the patient undergoes surgical aortic valve replacement. Pre-discharge transthoracic echocardiography (TTE) shows good prosthetic valve function with no gradient or regurgitation. In Case B, a 76-year-old patient is intubated upon arrival to the hospital for acute desaturation, found to have wide open AR on catheterization, and transferred for emergent intervention. Intraoperative TEE reveals QAV with flail leaflet and severe AR. Repair is considered but deferred ultimately due to emergent nature. Post-operative TTE demonstrates good prosthetic valve function with no regurgitation and normal biventricular function. CONCLUSIONS: QAV can present as progressive severe AS and acute AR, with symptoms first occurring in the seventh decade of life. The optimal treatment for QAV remains uncertain. Although aortic valve repair or transcatheter option may be feasible in some patients, aortic valve replacement remains a tenable option.


Subject(s)
Aortic Valve , Humans , Aged , Aortic Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Male , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography , Female , Heart Valve Prosthesis Implantation
18.
Arch Cardiovasc Dis ; 117(5): 304-312, 2024 May.
Article in English | MEDLINE | ID: mdl-38704289

ABSTRACT

BACKGROUND: Aortic valve infective endocarditis may be complicated by high-degree atrioventricular block in up to 10-20% of cases. AIM: To assess high-degree atrioventricular block occurrence, contributing factors, prognosis and evolution in patients referred for aortic infective endocarditis. METHODS: Two hundred and five patients referred for aortic valve infective endocarditis between January 2018 and March 2021 were included in this study. A comprehensive assessment of clinical, electrocardiographic, biological, microbiological and imaging data was conducted, with a follow-up carried out over 1 year. RESULTS: High-degree atrioventricular block occurred in 22 (11%) patients. In univariate analysis, high-degree atrioventricular block was associated with first-degree heart block at admission (odds ratio 3.1; P=0.015), periannular complication on echocardiography (odds ratio 6.9; P<0.001) and severe biological inflammatory syndrome, notably C-reactive protein (127 vs 90mg/L; P=0.011). In-hospital mortality (12.7%) was higher in patients with high-degree atrioventricular block (odds ratio 4.0; P=0.011) in univariate analysis. Of the 16 patients implanted with a permanent pacemaker for high-degree atrioventricular block and interrogated, only four (25%) were dependent on the pacing function at 1-year follow-up. CONCLUSIONS: High-degree atrioventricular block is associated with high inflammation markers and periannular complications, especially if first-degree heart block is identified at admission. High-degree atrioventricular block is a marker of infectious severity, and tends to raise the in-hospital mortality rate. Systematic assessment of patients admitted for infective endocarditis suspicion, considering these contributing factors, could indicate intensive care unit monitoring or even temporary pacemaker implantation in those at highest risk.


Subject(s)
Aortic Valve , Atrioventricular Block , Hospital Mortality , Pacemaker, Artificial , Humans , Male , Female , Atrioventricular Block/physiopathology , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Atrioventricular Block/mortality , Middle Aged , Aged , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/microbiology , Time Factors , Endocarditis/mortality , Endocarditis/diagnosis , Endocarditis/complications , Cardiac Pacing, Artificial , Retrospective Studies , Adult , Risk Assessment , Electrocardiography , Heart Rate , Aged, 80 and over , Heart Conduction System/physiopathology
20.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
SELECTION OF CITATIONS
SEARCH DETAIL
...