Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.265
Filter
1.
Catheter Cardiovasc Interv ; 103(7): 1093-1100, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38690931

ABSTRACT

BACKGROUND: As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates. AIMS: The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR. METHODS: PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups. RESULTS: The total patients' mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was -1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively. CONCLUSIONS: TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Recovery of Function , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aged , Treatment Outcome , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Retrospective Studies , Time Factors , Risk Factors , Middle Aged , Postoperative Complications/etiology , Hemodynamics
2.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
3.
Physiol Meas ; 45(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38599228

ABSTRACT

Objective.Significant aortic regurgitation is a common complication following left ventricular assist device (LVAD) intervention, and existing studies have not attempted to monitor regurgitation signals and undertake preventive measures during full support. Regurgitation is an adverse event that can lead to inadequate left ventricular unloading, insufficient peripheral perfusion, and repeated episodes of heart failure. Moreover, regurgitation occurring during full support due to pump position offset cannot be directly controlled through control algorithms. Therefore, accurate estimation of regurgitation during percutaneous left ventricular assist device (PLVAD) full support is critical for clinical management and patient safety.Approach.An estimation system based on the regurgitation model is built in this paper, and the unscented Kalman filter estimator (UKF) is introduced as an estimation approach. Three offset degrees and three heart failure states are considered in the investigation. Using the mock circulatory loop experimental platform, compare the regurgitation estimated by the UKF algorithm with the actual measured regurgitation; the errors are analyzed using standard confidence intervals of ±2 SDs, and the effectiveness of the mentioned algorithms is thus assessed. The generalization ability of the proposed algorithm is verified by setting different heart failure conditions and different rotational speeds. The root mean square error and correlation coefficient between the estimated and actual values are quantified and the statistical significance of accuracy differences in estimation is illustrated using one-way analysis of variance (One-Way ANOVA), which in turn assessed the accuracy and stability of the UKF algorithm.Main results.The research findings demonstrate that the regurgitation estimation system based on the regurgitation model and UKF can relatively accurately estimate the regurgitation status of patients during PLVAD full support, but the effect of myocardial contractility on the estimation accuracy still needs to be taken into account.Significance.The proposed estimation method in this study provides essential reference information for clinical practitioners, enabling them to promptly manage potential complications arising from regurgitation. By sensitively detecting LVAD adverse events, valuable insights into the performance and reliability of the LVAD device can be obtained, offering crucial feedback and data support for device improvement and optimization.


Subject(s)
Algorithms , Aortic Valve Insufficiency , Heart-Assist Devices , Aortic Valve Insufficiency/physiopathology , Humans , Heart Failure/physiopathology , Heart Failure/therapy , Time Factors , Models, Cardiovascular
4.
J Am Heart Assoc ; 13(9): e032532, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38686861

ABSTRACT

BACKGROUND: This study was performed to determine cusp causes of aortic regurgitation in patients with tricuspid aortic valves without significant aortic dilatation and define cusp pathologies amenable to surgical repair (aortic valve repair [AVr]) versus aortic valve replacement. METHODS AND RESULTS: We retrospectively reviewed surgical reports of consecutive adults with tricuspid aortic valves undergoing surgery for clinically significant aortic regurgitation within a prospective registry from January 2005 to September 2019. Valvular mechanisms were determined by systematic in vivo intraoperative quantification methods. Of 516 patients, 287 (56%) underwent repair (AVr; mean±SD age, 59.9±12.4 years; 81% men) and 229 (44%) underwent replacement (aortic valve replacement; mean±SD age, 62.8±13.8 years [P=0.01 compared to AVr]; 67% men). A single valvular mechanism was present in 454 patients (88%), with cusp prolapse (46%), retraction (24%), and perforation (18%) being the most common. Prolapse involved the right cusp in 86% of cases and was more frequent in men (P<0.001). Two-dimensional transesophageal echocardiography accuracy for predicting mechanisms was 73% to 82% for the right cusp, 55% to 61% for the noncoronary cusp, and 0% for the left-coronary cusp. Cusp prolapse, younger age, and larger patient size were associated with successful AVr (all P<0.03), whereas retraction, perforation, older age, and concomitant mitral repair were associated with aortic valve replacement (all P<0.03). CONCLUSIONS: Right cusp prolapse is the most frequent single valvular mechanism in patients with tricuspid aortic valve aortic regurgitation, followed by cusp retraction and perforation. The accuracy of 2-dimensional transesophageal echocardiography is limited for left and noncoronary cusp mechanistic assessment. Prolapse is associated with successful AVr, whereas retraction and perforation are associated with aortic valve replacement. With systematic intraoperative quantification methods and current surgical techniques, more than half of tricuspid aortic valve aortic regurgitation cases may be successfully repaired.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Humans , Male , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Middle Aged , Female , Retrospective Studies , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aged , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Treatment Outcome , Registries , Cardiac Valve Annuloplasty/methods
5.
Int J Cardiol ; 408: 132084, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38653434

ABSTRACT

BACKGROUND: In congenital aortic valve disease, quantifying aortic regurgitation (AR) varies by the measurement site. Our study aimed to identify the optimal site for AR assessment using 2D and 4D MR flow measurements, with a focus on vortices. METHODS: We retrospectively analysed 31 patients with congenital aortic valve disease, performing 2D and 4D MR flow measurements at the aortic valve, sinotubular junction (STJ), ascending aorta (AAo), and using midpulmonary artery measurements as a reference. We assessed percentage AR and net forward volumes, calculated linear correlations, and plotted Bland-Altman plots. Net forward flow at all aortic sites were correlated with the main pulmonary artery. Differences in AR between 2D and 4D flows were linked to vortices detected by 4D streamlines. RESULTS: The best agreement in % AR between 2D and 4D flows was at the aortic valve (mean difference 4D2D -2.9%, limits of agreement 8.7% to -14.3%; r2 = 0.7). Correlations weakened at STJ and AAo. Vortices in the ascending aorta led to AR overestimation in 2D measurements. Net forward flow at the aortic valve by 4D flow correlated closer with main pulmonary artery than did 2D flow. (Mean difference for 2D and 4D MR flow 7.5 ml and 4.2 ml, respectively). CONCLUSIONS: For congenital aortic valve disease, the most accurate AR quantification occurs at the aortic valve using 2D and 4D MR flow. Notably, vortices in the ascending aorta can result in AR overestimation with 2D MR flow.


Subject(s)
Aortic Valve Insufficiency , Humans , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Retrospective Studies , Female , Male , Adult , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Aortic Valve/physiopathology , Magnetic Resonance Imaging, Cine/methods , Blood Flow Velocity/physiology , Middle Aged , Adolescent , Young Adult , Child , Aortic Valve Disease/diagnostic imaging
6.
Inn Med (Heidelb) ; 65(5): 431-438, 2024 May.
Article in German | MEDLINE | ID: mdl-38635087

ABSTRACT

The pathophysiology of aortic valve diseases is of predominantly degenerative nature, characterized by calcific aortic valve stenosis, which is associated with a reduction in prognosis. The prevalence of aortic valve insufficiency also increases with advancing age. Timely causal treatment is crucial in the management of aortic valve diseases. Following the indication for intervention, the heart team plays a central role in evaluating the results and making therapeutic decisions that consider the patient's preferences. In the assessment of treatment options, considerations regarding the long-term perspective are particularly crucial, especially in younger patients. The most common therapeutic approach for aortic valve diseases is the introduction of a new valve prosthesis. In the majority of cases, this is now achieved through catheter-based implantation of a bioprosthetic heart valve, known as transcatheter aortic valve implantation (TAVI). Open surgical aortic valve replacement (AVR) is favored in younger patients with low surgical risk or in the case that TAVI is not feasible. In AVR, both biological and the longest-lasting mechanical prosthesis types are used. Surgical repair techniques are primarily applied in cases of aortic valve regurgitation. Notably, TAVI, as well as surgical procedures for the treatment of aortic valve diseases, have undergone significant advancements in recent years, including expanded indications for TAVI and, on the surgical side, in particular the development of minimally invasive surgical techniques.


Subject(s)
Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Aortic Valve/pathology , Heart Valve Prosthesis , Aortic Valve Disease/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Aortic Valve Stenosis/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Bioprosthesis
8.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Article in English | MEDLINE | ID: mdl-38577931

ABSTRACT

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Postoperative Complications , Prospective Studies , Recovery of Function , Risk Factors , Spain , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
Curr Cardiol Rep ; 26(5): 413-421, 2024 May.
Article in English | MEDLINE | ID: mdl-38517604

ABSTRACT

PURPOSE OF REVIEW: Cardiac magnetic resonance (CMR) is emerging as a valuable imaging modality for the assessment of aortic regurgitation (AR). In this review, we discuss the assessment of AR severity, left ventricular (LV) remodeling, and tissue characterization by CMR while highlighting the latest studies and addressing future research needs. RECENT FINDINGS: Recent studies have further established CMR-based thresholds of AR severity and LV remodeling that are associated with adverse clinical outcomes, and lower than current guideline criteria. In addition, tissue profiling with late gadolinium enhancement (LGE) and extracellular volume (ECV) quantification can reliably assess adverse myocardial tissue remodeling which is also associated with adverse outcomes. The strengths and reproducibility of CMR in evaluating ventricular volumes, tissue characteristics, and regurgitation severity position it as an excellent modality in evaluating and following AR patients. Advanced CMR techniques for the detection of tissue remodeling have shown significant potential and merit further investigation.


Subject(s)
Aortic Valve Insufficiency , Fibrosis , Severity of Illness Index , Ventricular Remodeling , Humans , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Fibrosis/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging/methods , Reproducibility of Results , Contrast Media
10.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Article in English | MEDLINE | ID: mdl-38533653

ABSTRACT

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Subject(s)
Aortic Valve Insufficiency , Balloon Valvuloplasty , Disease Models, Animal , Hemodynamics , Animals , Hemodynamics/drug effects , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Sus scrofa , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Equipment Design , Recovery of Function , Acute Disease , Cardiac Catheters , Time Factors , Severity of Illness Index , Ventricular Function, Left/drug effects
11.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38532517

ABSTRACT

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Cardiac Pacing, Artificial , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Prosthesis Failure , Recovery of Function , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
Int J Cardiovasc Imaging ; 40(5): 1049-1057, 2024 May.
Article in English | MEDLINE | ID: mdl-38519822

ABSTRACT

PURPOSE: This study investigated discordance between echocardiography (echo) and cardiac magnetic resonance (CMR) measurements of the left ventricle (LV) in pediatric patients with aortic and/or mitral regurgitation (AR/MR). METHODS: Retrospective cohort study of pediatric patients. The cohorts were comprised of patients with AR/MR vs. non-AR/MR. Left ventricular end diastolic volume (LVEDV) by CMR and left ventricular internal diameter diastolic (LVIDd) by echo were obtained from clinical reports then echo images were reviewed to remeasure LVEDV by bullet method. Left ventricular internal diameter systolic (LVIDs) and left ventricular ejection fraction (LVEF) measurements by echo and LVEF by CMR were obtained from clinical reports. Fractional shortening (FS%) was recalculated. Z-scores were calculated using normative data. Correlation between echo and CMR LV measurements was assessed using correlation coefficients. Bland-Altman plots assessed bias between imaging modalities. Receiver operator characteristic (ROC) analysis was performed for detection of LV enlargement and LV dysfunction. RESULTS: AR/MR patients had greater discrepancy in LV size interpretation by Z-score compared to non-AR/MR patients. This discrepancy persisted when the bullet method short axis measurements were incorporated. There was negative bias in echo-based measurements compared to CMR. The diagnostic performance of echo in identifying moderate LV enlargement was worse for AR/MR pediatrics patients. CONCLUSION: The discordant interpretation of LV size by echo compared to CMR is worse in pediatric patients with AR/MR when compared to patients without AR/MR even when short axis measurements are incorporated. This finding suggests non-uniform geometrical changes in the LV as it enlarges due to AR/MR.


Subject(s)
Aortic Valve Insufficiency , Heart Ventricles , Mitral Valve Insufficiency , Predictive Value of Tests , Stroke Volume , Ventricular Function, Left , Humans , Retrospective Studies , Female , Child , Male , Reproducibility of Results , Adolescent , Child, Preschool , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Age Factors , Magnetic Resonance Imaging, Cine , Infant , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology , Hypertrophy, Left Ventricular/diagnostic imaging , Hypertrophy, Left Ventricular/physiopathology
13.
Cardiovasc Eng Technol ; 15(2): 224-231, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38238600

ABSTRACT

PURPOSE: The valve-sparing aortic root replacement (VSARR) procedure was developed to preserve the aortic valve apparatus to replace aneurysmal aortic roots with synthetic grafts and to eliminate associated aortic regurgitation (AR). However, residual post-repair AR is not uncommon and has been found to be associated with recurrent AR and future reoperation. METHODS: We designed and manufactured a 3D-printed, external adjustable symmetrically extensible (EASE) aortic annuloplasty ring that can symmetrically reduce the aortic annulus diameter via a radial constriction, compliant mechanism. An ex vivo porcine VSARR model with annular dilation and AR was developed (n = 4) and used for hemodynamic, echocardiography, and high-speed videography data collection. RESULTS: After ring annuloplasty repair using the EASE aortic ring, the regurgitant fraction decreased from 23.6 ± 6.9% from the VSARR model to 7.4 ± 5.6% (p = 0.05), which was similar to that measured from baseline with a regurgitant fraction of 10.2 ± 3.9% (p = 0.34). The leaflet coaptation height after annuloplasty repair also significantly increased from that measured in VSARR model (0.4 ± 0.1 cm) to 0.9 ± 0.1 cm (p = 0.0004), a level similar to that measured in baseline (1.1 ± 0.1 cm, p = 0.28). CONCLUSION: Using an ex vivo VSARR model, the EASE ring successfully reduced AR by reducing the annular diameter and improving leaflet coaptation. With its broad applicability and ease of use, this device has the potential to have a significant impact on patients suffering worldwide from AR due to root aneurysms.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Cardiac Valve Annuloplasty , Heart Valve Prosthesis , Hemodynamics , Printing, Three-Dimensional , Prosthesis Design , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Animals , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Cardiac Valve Annuloplasty/instrumentation , Sus scrofa , Heart Valve Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Disease Models, Animal , Models, Cardiovascular
14.
Heart ; 110(10): 740-748, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38148159

ABSTRACT

OBJECTIVES: Grading the severity of moderate mixed aortic stenosis and regurgitation (MAVD) is challenging and the disease poorly understood. Identifying markers of haemodynamic severity will improve risk stratification and potentially guide timely treatment. This study aims to identify prognostic haemodynamic markers in patients with moderate MAVD. METHODS: Moderate MAVD was defined as coexisting moderate aortic stenosis (aortic valve area (AVA) 1.0-1.5 cm2) and moderate aortic regurgitation (vena contracta (VC) 0.3-0.6 cm). Consecutive patients diagnosed between 2015 and 2019 were included from a multicentre registry. The primary composite outcome of death or heart failure hospitalisation was evaluated among these patients. Demographics, comorbidities, echocardiography and treatment data were assessed for their prognostic significance. RESULTS: 207 patients with moderate MAVD were included, aged 78 (66-84) years, 56% male sex, AVA 1.2 (1.1-1.4) cm2 and VC 0.4 (0.4-0.5) cm. Over a follow-up of 3.5 (2.5-4.7) years, the composite outcome was met in 89 patients (43%). Univariable associations with the primary outcome included older age, previous myocardial infarction, previous cerebrovascular event, atrial fibrillation, New York Heart Association >2, worse renal function, tricuspid regurgitation ≥2 and mitral regurgitation ≥2. Markers of biventricular systolic function, cardiac remodelling and transaortic valve haemodynamics demonstrated an inverse association with the primary composite outcome. In multivariable analysis, peak aortic jet velocity (Vmax) was independently and inversely associated with the composite outcome (HR: 0.63, 95% CI 0.43 to 0.93; p=0.021) in an adjusted model along with age (HR: 1.05, 95% CI 1.03 to 1.08; p<0.001), creatinine (HR: 1.002, 95% CI 1.001 to 1.003; p=0.005), previous cerebrovascular event (85% vs 42%; HR: 3.04, 95% CI 1.54 to 5.99; p=0.001) and left ventricular ejection fraction (LVEF) (HR: 0.97, 95% CI 0.95 to 0.99; p=0.007). Patients with Vmax ≤2.8 m/s and LVEF ≤50% (n=27) had the worst outcome compared with the rest of the population (72% vs 41%; HR: 3.87, 95% CI 2.20 to 6.80; p<0.001). CONCLUSIONS: Patients with truly moderate MAVD have a high incidence of death and heart failure hospitalisation (43% at 3.5 (2.5-4.7) years). Within this group, a high-risk group characterised by disproportionately low aortic Vmax (≤2.8 m/s) and adverse remodelling (LVEF ≤50%) have the worst outcomes.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Severity of Illness Index , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/diagnosis , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/diagnostic imaging , Echocardiography , Heart Failure/physiopathology , Heart Failure/mortality , Hemodynamics , Prognosis , Registries , Retrospective Studies , Risk Assessment/methods , Risk Factors
15.
Gen Thorac Cardiovasc Surg ; 71(1): 51-58, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35852755

ABSTRACT

OBJECTIVES: This study aims to assess the long-term outcomes and prognostic predictors of asymptomatic patients with severe aortic regurgitation (AR) accompanied by left ventricular ejection fraction (LVEF) ≥ 55% and left ventricular end-diastolic diameter (LVEDD) > 65 mm undergoing aortic valve replacement (AVR). METHODS: We retrospectively studied 291 consecutive asymptomatic patients with severe AR accompanied by LVEF ≥ 55% and LVEDD > 65 mm undergoing AVR from January 2000 to December 2013. The long-term outcomes and prognostic predictors were evaluated. RESULTS: There were 2 (0.7%) in-hospital deaths caused by multiple organ failure. The overall survival rate was 95.2% at 5 years, 89.9% at 10 years, 85.9% at 15 years, and 85.9% at 20 years. The left ventricular end-systolic volume index (LVESVi) was an independent predictor of overall mortality, with 59 ml/m2 being the best cut-off value. The left ventricular (LV) dimension decreased within 1 year after surgery and sustained thereafter. There were 15.5% of patients had incomplete LV reverse remodeling. LVESVi was an independent predictor of incomplete LV reverse remodeling, with 56 ml/m2 being the best cut-off value. CONCLUSIONS: AVR can be performed with an acceptable outcome in patients with severe AR accompanied by LVEF ≥ 55% and LVEDD > 65 mm. The LVESVi has the best predictive value for prognosis and the cut-off value is 59 ml/m2, and has the best predictive value for incomplete LV reverse remodeling and the cut-off value is 56 ml/m2.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/surgery , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/surgery , Dilatation , Retrospective Studies , Stroke Volume/physiology , Ventricular Function, Left/physiology , Treatment Outcome , Prognosis
17.
J Thorac Cardiovasc Surg ; 163(2): 578-587.e1, 2022 Feb.
Article in English | MEDLINE | ID: mdl-32739166

ABSTRACT

BACKGROUND: Studies suggest that patients undergoing the Ross procedure for aortic insufficiency are at greater risk of autograft dilatation than those with aortic stenosis. By using a tailored Ross technique to mitigate autograft dilatation in patients with aortic insufficiency, we aimed to compare the biomechanical and morphologic remodeling of the autograft at 1 year between patients with aortic insufficiency and patients with aortic stenosis. METHODS: A total of 210 patients underwent a Ross procedure (2011-2016). Of those, 86 patients (mean age 43 ± 13 years; 32% were female) completed preoperative and postoperative cardiovascular magnetic resonance imaging. A total of 71 studies were suitable for analysis: 41 patients with aortic stenosis and 30 patients with aortic insufficiency. Nine healthy adults were used as controls. Autograft root dimensions, individual sinus volumes, and distensibility were measured using cardiovascular magnetic resonance. RESULTS: At 1 year, there was no difference in autograft root dimensions between patients with aortic stenosis (mean annulus 25.1 ± 3.1 mm and sinus diameters 35 ± 4.1 mm) and patients with aortic insufficiency (26.6 ± 3 mm and 37.1 ± 3.5 mm; P = .12 and .06, respectively). Relative sinus of Valsalva volumes were symmetrical in the aortic stenosis (right 34.8% ± 4%, left 33.7% ± 3.5%, noncoronary 31.4% ± 3.2%) and aortic insufficiency groups (34.8% ± 3.9%, 33.8% ± 2.8%, 31.3% ± 3.7%, P = .85, .92, and .82), and similar to those of healthy adults. Aortic root distensibility was reduced in both groups compared with healthy adults (P = .003), but was similar between aortic stenosis (3.12 ± 1.58 × 10-3 mm Hg-1) and aortic insufficiency (3.04 ± 1.15 × 10-3 mm Hg-1; P = .9). CONCLUSIONS: Using a tailored technique, there were no differences in the morphologic or biomechanical remodeling of the autograft root 1 year after the Ross procedure between patients with aortic stenosis and patients with aortic insufficiency. However, autograft roots are stiffer than native aortic roots.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Magnetic Resonance Imaging, Cine , Postoperative Complications/diagnostic imaging , Pulmonary Valve/transplantation , Adult , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Autografts , Bioprosthesis , Case-Control Studies , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Middle Aged , Postoperative Complications/physiopathology , Predictive Value of Tests , Recovery of Function , Time Factors , Treatment Outcome
18.
J Thorac Cardiovasc Surg ; 163(2): e161-e171, 2022 02.
Article in English | MEDLINE | ID: mdl-32747120

ABSTRACT

OBJECTIVE: The objective was to design and evaluate a clinically relevant, novel ex vivo bicuspid aortic valve model that mimics the most common human phenotype with associated aortic regurgitation. METHODS: Three bovine aortic valves were mounted asymmetrically in a previously validated 3-dimensional-printed left heart simulator. The non-right commissure and the non-left commissure were both shifted slightly toward the left-right commissure, and the left and right coronary cusps were sewn together. The left-right commissure was then detached and reimplanted 10 mm lower than its native height. Free margin shortening was used for valve repair. Hemodynamic status, high-speed videography, and echocardiography data were collected before and after the repair. RESULTS: The bicuspid aortic valve model was successfully produced and repaired. High-speed videography confirmed prolapse of the fused cusp of the baseline bicuspid aortic valve models in diastole. Hemodynamic and pressure data confirmed accurate simulation of diseased conditions with aortic regurgitation and the subsequent repair. Regurgitant fraction postrepair was significantly reduced compared with that at baseline (14.5 ± 4.4% vs 28.6% ± 3.4%; P = .037). There was no change in peak velocity, peak gradient, or mean gradient across the valve pre- versus postrepair: 293.3 ± 18.3 cm/sec versus 325.3 ± 58.2 cm/sec (P = .29), 34.3 ± 4.2 mm Hg versus 43.3 ± 15.4 mm Hg (P = .30), and 11 ± 1 mm Hg versus 9.3 ± 2.5 mm Hg (P = .34), respectively. CONCLUSIONS: An ex vivo bicuspid aortic valve model was designed that recapitulated the most common human phenotype with aortic regurgitation. These valves were successfully repaired, validating its potential for evaluating valve hemodynamics and optimizing surgical repair for bicuspid aortic valves.


Subject(s)
Aortic Valve Insufficiency , Bicuspid Aortic Valve Disease , Cardiovascular Surgical Procedures , Models, Anatomic , Animals , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/pathology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/surgery , Bicuspid Aortic Valve Disease/pathology , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/surgery , Cardiovascular Surgical Procedures/education , Cardiovascular Surgical Procedures/methods , Cattle , Echocardiography , Hemodynamics , Humans
19.
J Thorac Cardiovasc Surg ; 163(3): 900-910.e2, 2022 Mar.
Article in English | MEDLINE | ID: mdl-32620395

ABSTRACT

OBJECTIVE: The durability of root repair for acute type A aortic dissection is not well studied in the context of aortic insufficiency and stability of the sinuses of Valsalva. We compared clinical and functional outcomes in patients undergoing root repair and replacement for acute type A aortic dissection. METHODS: Of 716 patients undergoing surgery for acute type A aortic dissection, 585 (81.7%) underwent root repair and 131 (18.3%) underwent root replacement. Survival, cumulative incidence of reoperation, aortic insufficiency, and sinuses of Valsalva dilation were compared between the 2 groups. RESULTS: Survival at 1, 5, and 10 years was 84.1% versus 77.3%, 70.8% versus 69.2%, 57.6% versus 58.0% in the root repair and replacement groups, respectively (P = .69). Cumulative incidence of reoperation at 1, 5, and 10 years was 0.0% versus 0.8%, 1.4% versus 3.8%, and 3.4% versus 8.6% in the root repair and root replacement groups, respectively (P = .011). Multivariable Cox regression identified sinuses of Valsalva diameter 45 mm or more as a risk factor for proximal aortic reoperation (hazard ratio, 9.06; 95% confidence interval, 1.26-65.24). In a repeated-measures, linear, mixed-effects model, root replacement was associated with smaller follow-up of sinuses of Valsalva dimensions (ß = -0.66, P < .001). In an ordinal longitudinal mixed model, root replacement was associated with lower severity of postoperative aortic insufficiency (ß = -3.10, P < .001). CONCLUSIONS: Survival is similar, but the incidence of aortic insufficiency and root dilation may be greater after root repair compared with root replacement for acute type A aortic dissection.


Subject(s)
Aortic Aneurysm/surgery , Aortic Dissection/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve/surgery , Blood Vessel Prosthesis Implantation , Cardiac Surgical Procedures , Sinus of Valsalva/surgery , Acute Disease , Adult , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/mortality , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/mortality , Female , Humans , Male , Middle Aged , Postoperative Complications/surgery , Recurrence , Reoperation , Retrospective Studies , Risk Assessment , Risk Factors , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/physiopathology , Time Factors , Treatment Outcome
20.
J Thorac Cardiovasc Surg ; 163(1): 51-63.e5, 2022 01.
Article in English | MEDLINE | ID: mdl-32684389

ABSTRACT

OBJECTIVES: To assess intermediate-term outcomes of aortic root replacement with valve-sparing reimplantation of bicuspid aortic valves (BAV), compared with tricuspid aortic valves (TAV). METHODS: From January 2002 to July 2017, 92 adults underwent aortic root replacement with BAV reimplantation and 515 with TAV reimplantation at the Cleveland Clinic. Balancing-score matching based on 28 preoperative variables yielded 71 well-matched BAV and TAV pairs (77% of possible pairs) for comparison of postoperative mortality and morbidity, longitudinal echocardiogram data, aortic valve reoperation, and survival. RESULTS: In the BAV group, 1 hospital death occurred (1.1%); mortality among all reimplantations was 0.2%. Among matched patients, procedural morbidity was low and similar between BAV and TAV groups (1 stroke in TAV group; renal failure requiring dialysis, 1 patient each; red cell transfusion, 25% each). Five-year results: Severe aortic regurgitation was present in 7.4% of the BAV group and 2.9% of the TAV group (P = .7); 39% of BAV and 65% of TAV patients had none. Higher mean gradients (10 vs 7.4 mm Hg; P = .001) and left ventricular mass index (111 vs 101 g/m2; P = .5) were present in BAV patients. Freedom from aortic valve reoperation was 94% in the BAV group and 98% in the TAV group (P = .10), and survival was 100% and 95%, respectively (P = .07). CONCLUSIONS: Both BAV and TAV reimplantations can be performed with equal safety and good midterm outcomes; however, the constellation of higher gradients, less ventricular reverse remodeling, and more aortic valve reoperations with BAV reimplantations raises concerns requiring continued long-term surveillance.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Cardiac Valve Annuloplasty , Heart Valve Prosthesis Implantation , Long Term Adverse Effects , Postoperative Complications , Replantation , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Bicuspid Aortic Valve Disease/diagnosis , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/surgery , Cardiac Valve Annuloplasty/adverse effects , Cardiac Valve Annuloplasty/methods , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Long Term Adverse Effects/diagnosis , Long Term Adverse Effects/etiology , Long Term Adverse Effects/prevention & control , Male , Middle Aged , Organ Sparing Treatments/methods , Outcome and Process Assessment, Health Care , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Postoperative Complications/mortality , Postoperative Complications/surgery , Reoperation/methods , Reoperation/statistics & numerical data , Replantation/adverse effects , Replantation/methods , Survival Analysis , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...