Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.585
Filter
2.
J Cardiovasc Med (Hagerstown) ; 25(7): 529-538, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38829939

ABSTRACT

AIMS: This study assessed the outcomes of concomitant mitral valve disease and severe aortic stenosis in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Echocardiographic data of 813 patients with severe aortic stenosis undergoing transfemoral TAVR were collected, and clinical outcomes were analyzed for individuals with mitral stenosis and mitral regurgitation. RESULTS: The final cohort includes 788 patients with severe calcific aortic stenosis. Among single parameters of mitral stenosis, a smaller baseline mitral valve area (MVA) by the continuity equation and higher postprocedural mean mitral gradients (MMG) were associated with an increased risk of death at 1 year (P-values 0.02 and <0.01, respectively), but no correlation with outcomes was demonstrated after multivariate adjustment for major prognosticators. Mitral stenosis (based on MVA + MMG) was not associated with complications or mortality. Mitral regurgitation was present in 94.6% of the population at baseline and regressed by at least one grade post-TAVR in 28% of the patients. The improvement in mitral regurgitation was associated with a greater prosthetic effective orifice area (P-value 0.03). Significant (at least moderate) residual mitral regurgitation was correlated with short-term complications and shown to be an independent predictor of 1-year mortality (P-value 0.02, odds ratio (OR) 5.37, confidence interval 1.34-21.5). CONCLUSION: Mitral regurgitation has a greater impact on TAVR patients than mitral stenosis as assessed by functional methods.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Mitral Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/mortality , Mitral Valve Stenosis/physiopathology , Mitral Valve Stenosis/complications , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/complications , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aged , Treatment Outcome , Severity of Illness Index , Retrospective Studies , Prognosis , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Calcinosis/mortality , Calcinosis/diagnostic imaging , Calcinosis/complications , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Echocardiography
4.
Comput Biol Med ; 176: 108526, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749328

ABSTRACT

Aortic valve replacement has become an increasing concern due to the rising prevalence of aortic stenosis in an ageing population. Existing replacement options have limitations, necessitating the development of improved prosthetic aortic valves. In this study, flow characteristics during systole in a stenotic aortic valve case are compared with those downstream of two newly designed surgical bioprosthetic aortic valves (BioAVs). To do so, advanced three-dimensional fluid-structure interaction simulations are conducted and dedicated analysis methods to investigate jet flow configuration and vortex dynamics are developed. Our findings reveal that the stenotic case maintains a high jet flow eccentricity due to a fixed orifice geometry, resulting in flow separation and increased vortex stretching and tilting in the commissural low-flow regions. One BioAV design introduces non-axisymmetric leaflet motion, which reduces the maximum jet velocity and forms more vortical structures. The other BioAV design produces a fixed symmetric triangular jet shape due to non-moving leaflets and exhibits favourable vorticity attenuation, revealed by negative temporally and spatially averaged projected vortex stretching values, and significantly reduced drag. Therefore, this study highlights the benefits of custom-designed aortic valves in the context of their replacement through comprehensive and novel flow analyses. The results emphasise the importance of analysing jet flow, vortical structures, momentum balance and vorticity transport for thoroughly evaluating aortic valve performance.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Models, Cardiovascular , Humans , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve/physiology , Hemodynamics/physiology , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Blood Flow Velocity , Bioprosthesis
5.
Comput Biol Med ; 176: 108552, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38754219

ABSTRACT

Severe aortic valve stenosis can lead to heart failure and aortic valve replacement (AVR) is the primary treatment. However, increasing prevalence of aortic stenosis cases reveal limitations in current replacement options, necessitating improved prosthetic aortic valves. We investigate flow disturbances downstream of severe aortic stenosis and two bioprosthetic aortic valve (BioAV) designs using advanced energy-based analyses. Three-dimensional high-fidelity fluid-structure interaction simulations have been conducted and a dedicated and novel spectral analysis has been developed to characterise the kinetic energy (KE) carried by eddies in the wavenumber space. In addition, new field quantities, i.e. modal KE anisotropy intensity as well as normalised helicity intensity, are introduced. Spectral analysis shows kinetic energy (KE) decay variations, with the stenotic case aligning with Kolmogorov's theory, while BioAV cases differing. We explore the impact of flow helicity on KE transfer and decay in BioAVs. Probability distributions of modal KE anisotropy unveil flow asymmetries in the stenotic and one BioAV cases. Moreover, an inverse correlation between temporally averaged modal KE anisotropy and normalised instantaneous helicity intensity is noted, with the coefficient of determination varying among the valve configurations. Leaflet dynamics analysis highlights a stronger correlation between flow and biomechanical KE anisotropy in one BioAV due to higher leaflet displacement magnitude. These findings emphasise the role of valve architecture in aortic turbulence as well as its importance for BioAV performance and energy-based design enhancement.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Models, Cardiovascular , Humans , Aortic Valve/physiopathology , Aortic Valve/surgery , Anisotropy , Hemodynamics/physiology , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging
6.
J Cardiothorac Surg ; 19(1): 301, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38812010

ABSTRACT

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital anomaly characterized by the presence of four cusps instead of the usual three. It is estimated to occur in less than 0.05% of the population, with Type A (four equal-sized leaflets) accounting for roughly 30% of QAV subtypes. Based on limited clinical series, the usual presentation is progressive aortic valve regurgitation (AR) with symptoms occurring in the fourth to sixth decade of life. Severe aortic valve stenosis (AS) and acute AR are very uncommon. CASE PRESENTATION: We describe two cases of Type A QAV in patients who remained asymptomatic until their seventies with very uncommon presentations: one with severe AS and one with acute, severe AR and flail leaflet. In Case A, a 72-year-old patient with history of moderate AS presents to clinic with progressive exertional dyspnea. During work-up for transcatheter vs. surgical replacement pre-operative computed tomography angiogram (CTA) reveals a quadricuspid aortic valve with severe AS, and the patient undergoes surgical aortic valve replacement. Pre-discharge transthoracic echocardiography (TTE) shows good prosthetic valve function with no gradient or regurgitation. In Case B, a 76-year-old patient is intubated upon arrival to the hospital for acute desaturation, found to have wide open AR on catheterization, and transferred for emergent intervention. Intraoperative TEE reveals QAV with flail leaflet and severe AR. Repair is considered but deferred ultimately due to emergent nature. Post-operative TTE demonstrates good prosthetic valve function with no regurgitation and normal biventricular function. CONCLUSIONS: QAV can present as progressive severe AS and acute AR, with symptoms first occurring in the seventh decade of life. The optimal treatment for QAV remains uncertain. Although aortic valve repair or transcatheter option may be feasible in some patients, aortic valve replacement remains a tenable option.


Subject(s)
Aortic Valve , Humans , Aged , Aortic Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Male , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography , Female , Heart Valve Prosthesis Implantation
7.
PLoS One ; 19(5): e0303496, 2024.
Article in English | MEDLINE | ID: mdl-38739622

ABSTRACT

INTRODUCTION: Rheumatic heart disease (RHD), degenerative aortic stenosis (AS), and congenital valve diseases are prevalent in sub-Saharan Africa. Many knowledge gaps remain in understanding disease mechanisms, stratifying phenotypes, and prognostication. Therefore, we aimed to characterise patients through clinical profiling, imaging, histology, and molecular biomarkers to improve our understanding of the pathophysiology, diagnosis, and prognosis of RHD and AS. METHODS: In this cross-sectional, case-controlled study, we plan to recruit RHD and AS patients and compare them to matched controls. Living participants will undergo clinical assessment, echocardiography, CMR and blood sampling for circulatory biomarker analyses. Tissue samples will be obtained from patients undergoing valve replacement, while healthy tissues will be obtained from cadavers. Immunohistology, proteomics, metabolomics, and transcriptome analyses will be used to analyse circulatory- and tissue-specific biomarkers. Univariate and multivariate statistical analyses will be used for hypothesis testing and identification of important biomarkers. In summary, this study aims to delineate the pathophysiology of RHD and degenerative AS using multiparametric CMR imaging. In addition to discover novel biomarkers and explore the pathomechanisms associated with RHD and AS through high-throughput profiling of the tissue and blood proteome and metabolome and provide a proof of concept of the suitability of using cadaveric tissues as controls for cardiovascular disease studies.


Subject(s)
Aortic Valve Stenosis , Biomarkers , Rheumatic Heart Disease , Humans , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/physiopathology , Rheumatic Heart Disease/metabolism , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/metabolism , Aortic Valve Stenosis/physiopathology , Biomarkers/metabolism , Case-Control Studies , Cross-Sectional Studies , Male , Female , Metabolomics/methods , Echocardiography/methods , Proteomics/methods , Magnetic Resonance Imaging/methods , Multiomics
8.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
9.
BMC Cardiovasc Disord ; 24(1): 253, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38750455

ABSTRACT

BACKGROUND: Primary coronary slow flow (CSF) is defined as delayed opacification of the distal epicardial vasculature during coronary angiography in the absence of relevant coronary artery stenoses. Microvascular disease is thought to be the underlying cause of this pathology. Epicardial fat tissue (EFT) is an active endocrine organ directly surrounding the coronary arteries that provides pro-inflammatory factors to the adjacent tissue by paracrine and vasocrine mechanisms. The aim of the present study was to investigate a potential association between EFT and primary CSF and whether EFT can predict the presence of primary CSF. METHODS: Between 2016 and 2017, n = 88 patients with high-grade aortic stenosis who were planned for transcatheter aortic valve implantation (TAVI) were included in this retrospective study. EFT volume was measured by pre-TAVI computed tomography (CT) using dedicated software. The presence of primary CSF was defined based on the TIMI frame count from the pre-TAVI coronary angiograms. RESULTS: Thirty-nine of 88 TAVI patients had CSF (44.3%). EFT volume was markedly higher in patients with CSF (142 ml [IQR 107-180] vs. 113 ml [IQR 89-147]; p = 0.009) and was strongly associated with the presence of CSF (OR 1.012 [95%CI 1.002-1.021]; p = 0.014). After adjustment, EFT volume was still an independent predictor of CSF (OR 1.016 [95%CI 1.004-1.026]; p = 0.009). CONCLUSION: Primary CSF was independently associated with increased EFT volume. Further studies are needed to validate this finding and elucidate whether a causal relationship exists.


Subject(s)
Adipose Tissue , Aortic Valve Stenosis , Coronary Angiography , Coronary Circulation , Pericardium , Predictive Value of Tests , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Female , Male , Retrospective Studies , Pericardium/diagnostic imaging , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Adipose Tissue/diagnostic imaging , Adipose Tissue/physiopathology , Aged, 80 and over , Risk Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Computed Tomography Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Epicardial Adipose Tissue
10.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Article in English | MEDLINE | ID: mdl-38771899

ABSTRACT

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Echocardiography, Doppler , Multidetector Computed Tomography , Predictive Value of Tests , Severity of Illness Index , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Male , Female , Multidetector Computed Tomography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Retrospective Studies , Aged , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Calcinosis/mortality , Echocardiography, Doppler/methods , Aged, 80 and over , Prognosis , ROC Curve , Hemodynamics , Middle Aged , Risk Factors
13.
JACC Cardiovasc Interv ; 17(10): 1252-1264, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38811107

ABSTRACT

BACKGROUND: Cardiac damage caused by aortic stenosis (AS) can be categorized into stages, which are associated with a progressively increasing risk of death after transcatheter aortic valve replacement (TAVR). OBJECTIVES: The authors investigated sex-related differences in cardiac damage among patients with symptomatic AS and the prognostic value of cardiac damage classification in women and men undergoing TAVR. METHODS: In a prospective registry, pre-TAVR echocardiograms were used to categorize patients into 5 stages of cardiac damage caused by AS. Differences in the extent of cardiac damage were compared according to sex, and its implications on clinical outcomes after TAVR were explored. RESULTS: Among 2,026 patients undergoing TAVR between August 2007 and June 2022 (995 [49.1%] women and 1,031 [50.9%] men), we observed sex-specific differences in the pattern of cardiac damage (women vs men; stage 0: 2.6% vs 3.1%, stage 1: 13.4% vs 10.1%, stage 2: 37.1% vs 39.5%, stage 3: 27.5% vs 15.6%, and stage 4: 19.4% vs 31.7%). There was a stepwise increase in 5-year all-cause mortality according to stage in women (HRadjusted: 1.43; 95% CI: 1.28-1.60, for linear trend) and men (HRadjusted: 1.26; 95% CI: 1.14-1.38, for linear trend). Female sex was associated with a lower 5-year mortality in early stages (stage 0, 1, or 2) but not in advanced stages (stage 3 or 4). CONCLUSIONS: The pattern of cardiac damage secondary to AS differed by sex. In early stages of cardiac damage, women had a lower 5-year mortality than men, whereas in more advanced stages, mortality was comparable between sexes. (SwissTAVI Registry; NCT01368250).


Subject(s)
Aortic Valve Stenosis , Health Status Disparities , Registries , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Male , Sex Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged , Risk Factors , Aged, 80 and over , Risk Assessment , Time Factors , Treatment Outcome , Prospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Severity of Illness Index
15.
Sci Rep ; 14(1): 12526, 2024 05 31.
Article in English | MEDLINE | ID: mdl-38822074

ABSTRACT

Transcatheter aortic valve replacement (TAVR) is a widely used intervention for patients with severe aortic stenosis. Identifying high-risk patients is crucial due to potential postprocedural complications. Currently, this involves manual clinical assessment and time-consuming radiological assessment of preprocedural computed tomography (CT) images by an expert radiologist. In this study, we introduce a probabilistic model that predicts post-TAVR mortality automatically using unprocessed, preprocedural CT and 25 baseline patient characteristics. The model utilizes CT volumes by automatically localizing and extracting a region of interest around the aortic root and ascending aorta. It then extracts task-specific features with a 3D deep neural network and integrates them with patient characteristics to perform outcome prediction. As missing measurements or even missing CT images are common in TAVR planning, the proposed model is designed with a probabilistic structure to allow for marginalization over such missing information. Our model demonstrates an AUROC of 0.725 for predicting all-cause mortality during postprocedure follow-up on a cohort of 1449 TAVR patients. This performance is on par with what can be achieved with lengthy radiological assessments performed by experts. Thus, these findings underscore the potential of the proposed model in automatically analyzing CT volumes and integrating them with patient characteristics for predicting mortality after TAVR.


Subject(s)
Aortic Valve Stenosis , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/methods , Tomography, X-Ray Computed/methods , Female , Male , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aged
18.
Laeknabladid ; 110(5): 247-253, 2024 May.
Article in Icelandic | MEDLINE | ID: mdl-38713559

ABSTRACT

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Humans , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Male , Aged , Risk Factors , Retrospective Studies , Iceland/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Stroke/epidemiology , Stroke/mortality , Stroke/etiology , Incidence , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Risk Assessment , Aged, 80 and over , Middle Aged
19.
Circ Cardiovasc Imaging ; 17(5): e015996, 2024 May.
Article in English | MEDLINE | ID: mdl-38771906

ABSTRACT

BACKGROUND: Extracellular volume fraction (ECV) is a marker for myocardial fibrosis and infiltration, can be quantified using cardiac computed tomography (ECVCT), and has prognostic utility in several diseases. This study aims to map out regional differences in ECVCT to obtain greater insights into the pathophysiological mechanisms of ECV expansion and its clinical implications. METHODS: Three prospective cohorts were included: patients with aortic stenosis (AS) and coexisting AS and transthyretin cardiac amyloidosis were referred for a transcatheter aortic valve replacement and had ECG-gated CT angiography and Technetium-99m-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy to differentiate between the 2 cohorts. Controls had CT angiography and cardiac magnetic resonance demonstrating no significant coronary artery disease or infarction. Global and regional ECVCT was analyzed, and its association with mortality was assessed for patients with AS. RESULTS: In 199 patients, controls (n=65; 66% male), AS (n=115), and coexisting AS and transthyretin cardiac amyloidosis (n=19) had a global ECVCT of 26.1 (25.0-27.8%) versus 29.1 (27.5-31.1%) versus 37.4 (32.5-46.6%), respectively; P<0.001. Across cohorts, ECVCT was higher at the base (versus apex), the inferoseptum (versus anterolateral wall), and the subendocardium (versus subepicardium); P<0.05 for all. Among patients with AS, epicardial ECVCT, rather than any other regional value or global ECVCT, was the strongest predictor of mortality at a median of 3.9 (max 6.3) years (adjusted hazard ratio, 1.21 [95% CI, 1.08-1.36]; P=0.002). CONCLUSIONS: Regional differences in ECVCT suggest a predilection for fibrosis and amyloid infiltration at the base, subendocardium, inferior wall, and septum more than the anterior and lateral myocardium. ECVCT can predict long-term mortality with the subepicardium demonstrating the strongest discriminatory power. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT03029026 and NCT03094143.


Subject(s)
Amyloid Neuropathies, Familial , Aortic Valve Stenosis , Computed Tomography Angiography , Fibrosis , Myocardium , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Male , Female , Aged , Prospective Studies , Computed Tomography Angiography/methods , Aged, 80 and over , Myocardium/pathology , Amyloid Neuropathies, Familial/diagnostic imaging , Amyloid Neuropathies, Familial/complications , Amyloid Neuropathies, Familial/mortality , Predictive Value of Tests , Prognosis , Coronary Angiography/methods , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/physiopathology , Middle Aged
20.
Echocardiography ; 41(5): e15829, 2024 May.
Article in English | MEDLINE | ID: mdl-38787527

ABSTRACT

PURPOSE: Aortic stenosis (AS) is a common valvular heart disease with high morbidity and mortality. Recently, the association between peak atrial longitudinal strain (PALS) and AS clinical outcomes has been identified. This systematic review evaluates the prognostic value of PALS for adverse events in AS. METHODS: We performed a systematic literature review to identify clinical studies that evaluated Speckle-Tracking Echocardiography (STE)-derived PALS to predict adverse outcomes in patients with AS. We excluded studies that compared echocardiography to computed tomography and studies that focused on diseases other than AS. RESULTS: We included 18 studies reporting on 2660 patients. Patients with symptomatic AS had decreased PALS when compared to patients with asymptomatic AS. Patients with AS who had adverse events had decreased PALS when compared to patients with AS with no events. Each unit increase of PALS was independently associated with decreased risk for the primary endpoint. PALS cut-off values were associated with increased risk for the primary endpoint. CONCLUSION: This systematic review suggests PALS as an independent predictor for cardiovascular events in patients with AS and highlights the importance of evaluating LA mechanics for AS prognosis.


Subject(s)
Aortic Valve Stenosis , Echocardiography , Heart Atria , Humans , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Prognosis , Echocardiography/methods , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Female
SELECTION OF CITATIONS
SEARCH DETAIL
...