Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 12.022
Filter
1.
Anal Chim Acta ; 1312: 342764, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834269

ABSTRACT

BACKGROUND: Osteopontin (OPN) is closely associated with tumorigenesis, growth, invasion, and immune escape and it serves as a plasma biomarker for hepatocellular carcinoma (HCC). Nevertheless, the accurate and rapid detection of low-abundance OPN still poses significant challenges. Currently, the majority of protein detection methods rely heavily on large precision instruments or involve complex procedures. Therefore, developing a simple, enzyme-free, rapid colorimetric analysis method with high sensitivity is imperative. RESULTS: In this study, we have developed a portable colorimetric biosensor by integrating the triple-helix aptamer probe (THAP) and catalytic hairpin assembly (CHA) strategy, named as T-CHA. After binding to the OPN, the trigger probe can be released from THAP, then initiates the CHA reaction and outputs the signal through the formation of a G-quadruplex/Hemin DNAzyme with horseradish peroxidase-like activity. Consequently, this colorimetric sensor achieves visual free-labeled detection without additional fluorophore modification and allows for accurate quantification by measuring the optical density of the solution at 650 nm. Under optimal conditions, the logarithmic values of various OPN concentrations exhibit satisfactory linearity in the range of 5 pg mL-1 to 5 ng mL-1, with a detection limit of 2.04 pg mL-1. Compared with the widely used ELISA strategy, the proposed T-CHA strategy is rapid (∼105 min), highly sensitive, and cost-effective. SIGNIFICANCE: The T-CHA strategy, leveraging the low background leakage of THAP and the high catalytic efficiency of CHA, has been successfully applied to the detection of OPN in plasma, demonstrating significant promise for the early diagnosis of HCC in point-of-care testing. Given the programmability of DNA and the universality of T-CHA, it can be readily modified for analyzing other useful tumor biomarkers.


Subject(s)
Aptamers, Nucleotide , Colorimetry , Osteopontin , Colorimetry/methods , Aptamers, Nucleotide/chemistry , Humans , Osteopontin/blood , Osteopontin/chemistry , Osteopontin/analysis , Biosensing Techniques/methods , DNA, Catalytic/chemistry , DNA, Catalytic/metabolism , Limit of Detection , G-Quadruplexes
2.
Anal Chim Acta ; 1312: 342762, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834277

ABSTRACT

Mucin1 (MUC1) is an extensively glycosylated transmembrane protein that is widely distributed and overexpressed on the surface of cancer cells, playing an important role in tumor occurrence and metastasis. Therefore, highly sensitive detection of MUC1 is of great significance for early diagnosis, treatment monitoring, and prognosis of cancer. Here, an ultra-sensitive photoelectrochemical (PEC) sensing platform was developed based on an aptamer amplification strategy for highly selective and sensitive detection of MUC1 overexpressed in serum and on cancer cell surfaces. The sensing platform utilized copper phthalocyanine to fabricate porous organic polymers (CuPc POPs), and was effectively integrated with g-C3N4/MXene to form a ternary heterojunction material (g-C3N4/MXene/CuPc POPs). This material effectively improved electron transfer capability, significantly enhanced light utilization, and greatly enhanced photoelectric conversion efficiency, resulting in a dramatic increase in photocurrent response. MUC1 aptamer 1 was immobilized on a chitosan-modified photoelectrode for the selective capture of MUC1 or MCF-7 cancer cells. When the target substance was present, MUC1 aptamer 2 labeled with methylene blue (MB) was specifically adsorbed on the electrode surface, leading to enhanced photocurrent. The concentration of MUC1 directly correlated with the number of MB molecules attracted to the electrode surface, establishing a linear relationship between photocurrent intensity and MUC1 concentration. The PEC biosensor exhibited excellent sensitivity for MUC1 detection with a wide detection range from 1 × 10-7 to 10 ng/mL and a detection limit of 8.1 ag/mL. The detection range for MCF-7 cells was from 2 × 101 to 2 × 106 cells/mL, with the capability for detecting single MCF-7 cells. The aptamer amplification strategy significantly enhanced PEC performance, and open up a promising platform to establish high selectivity, stability, and ultrasensitive analytical techniques.


Subject(s)
Aptamers, Nucleotide , Electrochemical Techniques , Mucin-1 , Polymers , Mucin-1/analysis , Humans , Aptamers, Nucleotide/chemistry , Electrochemical Techniques/methods , MCF-7 Cells , Porosity , Polymers/chemistry , Limit of Detection , Biosensing Techniques/methods , Indoles/chemistry , Photochemical Processes , Organometallic Compounds/chemistry
3.
Anal Chim Acta ; 1312: 342778, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834257

ABSTRACT

BACKGROUND: The technology of capturing circulating tumor cells (CTCs) plays a crucial role in the diagnosis, evaluation of therapeutic efficacy, and prediction of prognosis in lung cancer. However, the presence of complex blood environment often results in severe nonspecific protein adsorption and interferences from blood cells, which negatively impacts the specificity of CTCs capture. There is a great need for development of novel nanomaterials for CTCs capture with prominent anti-nonspecific adsorptions from proteins or blood cells. RESULTS: We present a novel immune magnetic probe Fe3O4@(PEI/AA)4@Apt. The surface of Fe3O4 particles was modified with four layers of PEI/AA composite by layer-by-layer assembly. Furthermore, aptamers targeting epithelial marker EpCAM (SYL3C) and mesenchymal marker CSV (ZY5C) were simultaneously connected on Fe3O4@(PEI/AA)4 to improve the detection of different phenotypic CTCs and reduce false negatives. The results demonstrated that the (PEI/AA)4 coatings not only minimized non-specific protein adsorptions, but also significantly reduced the adsorption rate of red blood cells to a mere 1 %, as a result of which, the Fe3O4@(PEI/AA)4@Apt probe achieved a remarkably high capture efficiency toward CTCs (95.9 %). In the subsequent validation of clinical samples, the probe was also effective in capturing rare CTCs from lung cancer patients. SIGNIFICANCE AND NOVELTY: A (PEI/AA) polymerized composite with controllable layers was fabricated by layer-by-layer self-assembly technique, which displayed remarkable anti-nonspecific adsorption capabilities toward proteins and cells. Importantly, Fe3O4@(PEI/AA)4@Apt probe significantly improved CTCs capture purity in lung cancer patients to 89.36 %. For the first time, this study combined controllable (PEI/AA) layers with magnetic separation to innovatively build a resistant interface that significantly improves the specific capture performances of CTCs, broadening the application of this polymerized composite.


Subject(s)
Alginates , Neoplastic Cells, Circulating , Polyethyleneimine , Humans , Neoplastic Cells, Circulating/pathology , Polyethyleneimine/chemistry , Alginates/chemistry , Magnetite Nanoparticles/chemistry , Lung Neoplasms/pathology , Aptamers, Nucleotide/chemistry , Adsorption , Surface Properties , Epithelial Cell Adhesion Molecule/immunology
4.
Anal Chim Acta ; 1312: 342780, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834272

ABSTRACT

BACKGROUND: The convenient preparation and application of functionalized organic-inorganic hybrid monolithic materials have obtained substantial interest in the pretreatment of complex samples by solid-phase extraction (SPE). Compared to the in-tube solid-phase microextraction in fused-silica capillaries, micro SPE in plastic pipette tips have fascinating merits for the easily operated enrichment of trace target analytes from biological samples. However, the poor compatibility of organic-inorganic hybrid monoliths with plastics leads to the rare appearance of commercial hybrid monolithic pipette tips (HMPTs). Therefore, how to synthesize the organic-inorganic hybrid monolithic materials with better extraction performance in plastic pipette tips becomes a challenge. RESULTS: We develop a facile and cheap strategy to immobilize organic-inorganic hybrid monoliths in pipette tips. Melamine sponge was employed as the supporting skeleton to in situ assemble amine- and thiol-bifunctionalized hybrid monolithic material via "one pot" in a pipette tip, and gold nanoparticles (GNPs) and thiol-modified aptamer against human α-thrombin were sequentially attached to the hybrid monolith within the HMPTs. The average coverage density of the aptamer with GNPs as an intermediary reached as high as 818.5 pmol µL-1. The enriched thrombin concentration was determined by a sensitive enzymatic chromogenic assay with the limit of detection of 2 nM. The extraction recovery of thrombin at 10 nM in human serum was 86.1 % with a relative standard deviation of 6.1 %. This proposed protocol has been applied to the enrichment and determination of thrombin in real serum sample with strong anti-interference ability, low limit of detection and high recovery. SIGNIFICANCE: The amine- and thiol-bifunctionalized HMPTs prepared with sponge as the skeleton frame provided a novel substrate material to decorate aptamers for efficient enrichment of proteins. This enlightens us that we can take advantage of the tunability of sponge assisted HMPTs to produce and tailor a variety of micro SPE pipette tips for broader applications on the analysis of trace targets in complex biological, clinic and environmental samples.


Subject(s)
Aptamers, Nucleotide , Thrombin , Triazines , Triazines/chemistry , Triazines/isolation & purification , Aptamers, Nucleotide/chemistry , Humans , Thrombin/analysis , Thrombin/isolation & purification , Gold/chemistry , Metal Nanoparticles/chemistry , Solid Phase Extraction/methods
5.
Mikrochim Acta ; 191(7): 383, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38861005

ABSTRACT

A competitive-type photoelectrochemical (PEC) aptasensor coupled with a novel Au@Cd:SnO2/SnS2 nanocomposite was designed for the detection of 17ß-estradiol (E2) in microfluidic devices. The designed Au@Cd:SnO2/SnS2 nanocomposites exhibit high photoelectrochemical activity owing to the good matching of cascade band-edge and the efficient separation of photo-generated e-/h+ pairs derived from the Cd-doped defects in the energy level. The Au@Cd:SnO2/SnS2 nanocomposites were loaded into carbon paste electrodes (CPEs) to immobilize complementary DNA (cDNA) and estradiol aptamer probe DNA (E2-Apt), forming a double-strand DNA structure on the CPE surface. As the target E2 interacts with the double-strand DNA, E2-Apt is sensitively released from the CPE, subsequently increasing the photocurrent intensity due to the reduced steric hindrance of the electrode surface. The competitive-type sensing mechanism, combined with high PEC activity of the Au@Cd:SnO2/SnS2 nanocomposites, contributed to the rapid and sensitive detection of E2 in a "signal on" manner. Under the optimized conditions, the PEC aptasensor exhibited a linear range from 1.0 × 10-13 mol L-1 to 3.2 × 10-6 mol L-1 and a detection limit of 1.2 × 10-14 mol L-1 (S/N = 3). Moreover, the integration of microfluidic device with smartphone controlled portable electrochemical workstation enables the on-site detection of E2. The small sample volume (10 µL) and short analysis time (40 min) demonstrated the great potential of this strategy for E2 detection in rat serum and river water. With these advantages, the PEC aptasensor can be utilized for point-of-care testing (POCT) in both clinical and environmental applications.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Electrochemical Techniques , Estradiol , Gold , Limit of Detection , Nanocomposites , Sulfides , Tin Compounds , Tin Compounds/chemistry , Aptamers, Nucleotide/chemistry , Nanocomposites/chemistry , Gold/chemistry , Estradiol/analysis , Estradiol/blood , Estradiol/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Sulfides/chemistry , Cadmium/chemistry , Cadmium/analysis , Photochemical Processes , Lab-On-A-Chip Devices
6.
Langmuir ; 40(23): 12117-12123, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38826127

ABSTRACT

Electrochemical aptamer-based (E-AB) sensors are a promising class of biosensors which use structure-switching redox-labeled oligonucleotides (aptamers) codeposited with passivating alkanethiol monolayers on electrode surfaces to specifically bind and detect target analytes. Signaling in E-AB sensors is an outcome of aptamer conformational changes upon target binding, with the sequence of the aptamer imparting specificity toward the analyte of interest. The change in conformation translates to a change in electron transfer between the redox label attached to the aptamer and the underlying electrode and is related to analyte concentration, allowing specific electrochemical detection of nonelectroactive analytes. E-AB sensor measurements are reagentless with time resolutions of seconds or less and may be miniaturized into the submicron range. Traditionally these sensors are fabricated using thiol-on-gold chemistry. Here we present an alternate immobilization chemistry, gold-alkyne binding, which results in an increase in sensor lifetimes under ideal conditions by up to ∼100%. We find that gold-alkyne binding is spontaneous and supports efficient E-AB sensor signaling with analytical performance characteristics similar to those of thiol generated monolayers. The surface modification differs from gold-thiol binding only in the time and aptamer concentration required to achieve similar aptamer surface coverages. In addition, alkynated aptamers differ from their thiolated analogues only by their chemical handle for surface attachment, so any existing aptamers can be easily adapted to utilize this attachment strategy.


Subject(s)
Alkynes , Aptamers, Nucleotide , Biosensing Techniques , Electrochemical Techniques , Gold , Aptamers, Nucleotide/chemistry , Gold/chemistry , Biosensing Techniques/methods , Electrochemical Techniques/methods , Alkynes/chemistry , Electrodes , Sulfhydryl Compounds/chemistry
7.
Cochrane Database Syst Rev ; 6: CD015804, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38829176

ABSTRACT

RATIONALE: Neovascular age-related macular degeneration (AMD) is a progressive eye disease characterized by choroidal neovascularization (CNV) and is a leading cause of vision loss and disability worldwide. Although intravitreal anti-vascular endothelial growth factor (anti-VEGF) therapy is an effective treatment option that helps to prevent vision loss or to improve visual acuity in people with neovascular AMD, treatment imposes a significant financial burden on patients and healthcare systems. A biosimilar is a biological product that has been developed to be nearly identical to a previously approved biological product. The use of biosimilars may help reduce costs and so may increase patient access to effective biologic medicines with similar levels of safety to the drugs on which they are based. OBJECTIVES: To assess the benefits and harms of anti-VEGF biosimilar agents compared with their corresponding anti-VEGF agents (i.e. the reference products) that have obtained regulatory approval for intravitreal injections in people with neovascular AMD. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, two other databases, and two trials registries together with reference checking and contact with study authors to identify studies that are included in the review. The latest search date was 2 June 2023. ELIGIBILITY CRITERIA: We included randomized controlled trials (RCTs) that compared approved anti-VEGF biosimilars with their reference products for treating the eyes of adult participants (≥ 50 years) who had an active primary or recurrent choroidal neovascularization lesion secondary to neovascular AMD. OUTCOMES: Our outcomes were: best-corrected visual acuity (BCVA), central subfield thickness (CST), vision-related quality of life, serious ocular and non-ocular adverse events (AE), treatment-emergent adverse events (TEAEs), anti-drug antibodies (ADAs), and serum concentrations of biosimilars and reference drugs. RISK OF BIAS: We assessed the risk of bias (RoB) for seven outcomes reported in a summary of findings table by using the Cochrane RoB 2 tool. SYNTHESIS METHODS: We synthesized results for each outcome using meta-analysis, where possible, by calculating risk ratios (RR) and mean differences (MD) with 95% confidence intervals (CI) for dichotomous outcomes and continuous outcomes, respectively. Where this was not possible due to the nature of the data, we summarized the results narratively. We used GRADE to assess the certainty of evidence for prespecified outcomes. INCLUDED STUDIES: We included nine parallel-group multi-center RCTs that enrolled a total of 3814 participants (3814 participating eyes), with sample sizes that ranged from 160 to 705 participants per study. The mean age of the participants in these studies ranged from 67 to 76 years, and the proportion of women ranged from 26.5% to 58.7%. Ranibizumab (Lucentis) was the reference product in seven studies, and aflibercept (Eyelea) was the reference product in two others. All the included studies had been supported by industry. The follow-up periods ranged from 12 to 52 weeks (median 48 weeks). Five studies (56%) were conducted in multi-country settings across Europe, North America and Asia, two studies in India, and one each in Japan and the Republic of Korea. We judged all the included studies to have met high methodological standards. SYNTHESIS OF RESULTS: With regard to efficacy, our meta-analyses demonstrated that anti-VEGF biosimilars for neovascular AMD resulted in little to no difference compared with the reference products for BCVA change at 8 to 12 weeks (MD -0.55 Early Treatment Diabetic Retinopathy Study (ETDRS) letters, 95% CI -1.17 to 0.07; 8 studies, 3603 participants; high-certainty evidence) and the proportion of participants who lost fewer than 15 letters in BCVA at 24 to 48 weeks (RR 0.99, 95% CI 0.98 to 1.01; 7 studies, 2658 participants; moderate-certainty evidence). Almost all participants (96.6% in the biosimilar group and 97.0% in the reference product group) lost fewer than 15 letters in BCVA. The evidence from two studies suggested that there was no evidence of difference between biosimilars and reference products in vision-related quality of life measured by the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25) summary scores at 24 to 48 weeks (MD 0.82, 95% CI -0.70 to 2.35; 2 studies, 894 participants; moderate-certainty evidence). With regard to the safety profile, meta-analyses also revealed little to no difference between anti-VEGF biosimilars and the reference products for the proportion of participants who experienced serious ocular AEs (RR 1.24, 95% CI 0.68 to 2.26; 7 studies, 3292 participants; moderate-certainty evidence), and for TEAEs leading to investigational product discontinuation or death (RR 0.96, 95% CI 0.63 to 1.46; 8 studies, 3497 participants; moderate-certainty evidence). Overall, 1.4% of participants in the biosimilar group and 1.2% in the reference product group experienced serious ocular adverse events. The most frequently documented serious ocular AEs were retinal hemorrhage and endophthalmitis. Although the evidence is of low certainty due to imprecision, meta-analysis suggested that anti-VEGF biosimilars led to no difference compared with the reference products for cumulative incidence of ADAs (RR 0.84, 95% CI 0.58 to 1.22; 8 studies, 3066 participants; low-certainty evidence) or mean maximum serum concentrations (MD 0.42 ng/mL, 95% CI -0.22 to 1.05; subgroup of 3 studies, 100 participants; low-certainty evidence). We judged the overall risk of bias to be low for all studies. AUTHORS' CONCLUSIONS: In our review, low to high certainty evidence suggests that there is little to no difference, to date, between the anti-VEGF biosimilars approved for treating neovascular AMD and their reference products in terms of benefits and harms. While anti-VEGF biosimilars may be a viable alternative to reference products, current evidence for their use is based on a limited number of studies - particularly for comparison with aflibercept - with sparse long-term safety data, and infrequent assessment of quality of life outcomes. Our effect estimates and conclusions may be modified once findings have been reported from studies that are currently ongoing, and studies of biosimilar agents that are currently in development. FUNDING: Cochrane Eyes and Vision US Project is supported by grant UG1EY020522, National Eye Institute, National Institutes of Health. Takeshi Hasegawa and Hisashi Noma were supported by Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science (Grant numbers: 22H03554, 19K03092, 24K06239). REGISTRATION: Protocol available via doi.org/10.1002/14651858.CD015804.


Subject(s)
Angiogenesis Inhibitors , Bevacizumab , Biosimilar Pharmaceuticals , Macular Degeneration , Ranibizumab , Vascular Endothelial Growth Factor A , Aged , Humans , Angiogenesis Inhibitors/therapeutic use , Angiogenesis Inhibitors/adverse effects , Antibodies, Monoclonal, Humanized/therapeutic use , Aptamers, Nucleotide/therapeutic use , Bevacizumab/therapeutic use , Bias , Biosimilar Pharmaceuticals/therapeutic use , Choroidal Neovascularization/drug therapy , Intravitreal Injections , Macular Degeneration/drug therapy , Randomized Controlled Trials as Topic , Ranibizumab/therapeutic use , Receptors, Vascular Endothelial Growth Factor/therapeutic use , Recombinant Fusion Proteins/therapeutic use , Vascular Endothelial Growth Factor A/antagonists & inhibitors , Visual Acuity/drug effects , Middle Aged , Male , Female
8.
Mol Biol Rep ; 51(1): 722, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38829419

ABSTRACT

BACKGROUND: Yersinia pestis is a bacterium that causes the disease plague. It has caused the deaths of many people throughout history. The bacterium possesses several virulence factors (pPla, pFra, and PYV). PFra plasmid encodes fraction 1 (F1) capsular antigen. F1 protein protects the bacterium against host immune cells through phagocytosis process. This protein is specific for Y. pestis. Many diagnostic techniques are based on molecular and serological detection and quantification of F1 protein in different food and clinical samples. Aptamers are small nucleic acid sequences that can act as specific ligands for many targets.This study, aimed to isolate the high-affinity ssDNA aptamers against F1 protein. METHODS AND RESULTS: In this study, SELEX was used as the main strategy in screening aptamers. Moreover, enzyme-linked aptamer sorbent assay (ELASA) and surface plasmon resonance (SPR) were used to determine the affinity and specificity of obtained aptamers to F1 protein. The analysis showed that among the obtained aptamers, the three aptamers of Yer 21, Yer 24, and Yer 25 were selected with a KD value of 1.344E - 7, 2.004E - 8, and 1.68E - 8 M, respectively. The limit of detection (LoD) was found to be 0.05, 0.076, and 0.033 µg/ml for Yer 21, Yer 24, and Yer 25, respectively. CONCLUSION: This study demonstrated that the synthesized aptamers could serve as effective tools for detecting and analyzing the F1 protein, indicating their potential value in future diagnostic applications.


Subject(s)
Aptamers, Nucleotide , Bacterial Proteins , SELEX Aptamer Technique , Yersinia pestis , Yersinia pestis/genetics , SELEX Aptamer Technique/methods , Bacterial Proteins/genetics , Surface Plasmon Resonance/methods , Humans , Plague/diagnosis , Plague/microbiology , Antigens, Bacterial
9.
Anal Chim Acta ; 1307: 342631, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38719408

ABSTRACT

BACKGROUND: Simultaneous detection of food contaminants is crucial in addressing the collective health hazards arising from the presence of multiple contaminants. However, traditional multi-competitive surface-enhanced Raman scattering (SERS) aptasensors face difficulties in achieving simultaneous accurate detection of multiple target substances due to the uncontrollable SERS "hot spots". In this study, using chloramphenicol (CAP) and estradiol (E2) as two target substances, we introduced a novel approach that combines machine learning methods with a dual SERS aptasensor, enabling simultaneous high-sensitivity and accurate detection of both target substances. RESULTS: The strategy effectively minimizes the interference from characteristic Raman peaks commonly encountered in traditional multi-competitive SERS aptasensors. For this sensing system, the Au@4-MBA@Ag nanoparticles modified with sulfhydryl (SH)-CAP aptamer and Au@DTNB@Ag NPs modified with sulfhydryl (SH)-E2 aptamer were used as signal probes. Additionally, Fe3O4@Au nanoflowers integrated with SH-CAP aptamer complementary DNA and SH-E2 aptamer complementary DNA were used as capture probes, respectively. When compared to linear regression random forest, and support vector regression (SVR) models, the proposed artificial neural network (ANN) model exhibited superior precision, demonstrating R2 values of 0.963, 0.976, 0.991, and 0.970 for the training set, test set, validation set, and entire dataset, respectively. Validation with ten spectral groups reported an average error of 244 µg L-1. SIGNIFICANCE: The essence of our study lies in its capacity to address a persistent challenge encountered by traditional multiple competitive SERS aptasensors - the interference generated by uncontrollable SERS "hot spots" that hinders simultaneous quantification. The accuracy of the predictive model for simultaneous detection of two target substances was significantly improved using machine learning tools. This innovative technique offers promising avenues for the accurate and high-sensitive simultaneous detection of multiple food and environmental contaminants.


Subject(s)
Aptamers, Nucleotide , Gold , Machine Learning , Metal Nanoparticles , Silver , Spectrum Analysis, Raman , Aptamers, Nucleotide/chemistry , Silver/chemistry , Gold/chemistry , Metal Nanoparticles/chemistry , Chloramphenicol/analysis , Estradiol/analysis , Biosensing Techniques/methods , Food Contamination/analysis , Limit of Detection
10.
Mikrochim Acta ; 191(5): 296, 2024 05 03.
Article in English | MEDLINE | ID: mdl-38702534

ABSTRACT

A covalent organic framework-based strategy was designed for label-free colorimetric detection of pesticides. Covalent organic framework-based nanoenzyme with excellent oxidase-like catalytic activity was synthesized. Unlike other artificial enzymes, porphyrin-based covalent organic framework (p-COF) as the oxidase mimic showed highly catalytic chromogenic activity and good affinity toward TMB without the presence of H2O2, which can be used as substitute for peroxidase mimics and H2O2 system in the colorimetric reaction. Based on the fact that the pesticide-aptamer complex can inhibit the oxidase activity of p-COF and reduced the absorbance at 650 nm in UV-Vis spectrum, a label-free and facile colorimetric detection of pesticides was designed and fabricated. Under the optimized conditions, the COF-based colorimetric probe for pesticide detection displayed high sensitivity and selectivity. Taking fipronil for example the limit of detection was 2.7 ng/mL and the linear range was 5 -500,000 ng/mL. The strategy was successfully applied to the detection of pesticides with good recovery , which was in accordance with that of HPLC-MS/MS. The COF-based colorimetric detection was free of complicated modification H2O2, which guaranteed the accuracy and reliability of measurements. The COF-based sensing strategy is a potential candidate for the sensitive detection of pesticides of interests.


Subject(s)
Colorimetry , Limit of Detection , Metal-Organic Frameworks , Pesticides , Porphyrins , Colorimetry/methods , Pesticides/analysis , Metal-Organic Frameworks/chemistry , Porphyrins/chemistry , Hydrogen Peroxide/chemistry , Oxidoreductases/chemistry , Aptamers, Nucleotide/chemistry
11.
Nat Commun ; 15(1): 3684, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38693181

ABSTRACT

The metal-nucleic acid nanocomposites, first termed metal-nucleic acid frameworks (MNFs) in this work, show extraordinary potential as functional nanomaterials. However, thus far, realized MNFs face limitations including harsh synthesis conditions, instability, and non-targeting. Herein, we discover that longer oligonucleotides can enhance the synthesis efficiency and stability of MNFs by increasing oligonucleotide folding and entanglement probabilities during the reaction. Besides, longer oligonucleotides provide upgraded metal ions binding conditions, facilitating MNFs to load macromolecular protein drugs at room temperature. Furthermore, longer oligonucleotides facilitate functional expansion of nucleotide sequences, enabling disease-targeted MNFs. As a proof-of-concept, we build an interferon regulatory factor-1(IRF-1) loaded Ca2+/(aptamer-deoxyribozyme) MNF to target regulate glucose transporter (GLUT-1) expression in human epidermal growth factor receptor-2 (HER-2) positive gastric cancer cells. This MNF nanodevice disrupts GSH/ROS homeostasis, suppresses DNA repair, and augments ROS-mediated DNA damage therapy, with tumor inhibition rate up to 90%. Our work signifies a significant advancement towards an era of universal MNF application.


Subject(s)
Aptamers, Nucleotide , DNA, Catalytic , Stomach Neoplasms , Stomach Neoplasms/metabolism , Stomach Neoplasms/drug therapy , Stomach Neoplasms/genetics , Humans , Aptamers, Nucleotide/chemistry , Aptamers, Nucleotide/metabolism , Cell Line, Tumor , DNA, Catalytic/metabolism , DNA, Catalytic/chemistry , Animals , Receptor, ErbB-2/metabolism , Interferon Regulatory Factor-1/metabolism , Interferon Regulatory Factor-1/genetics , Reactive Oxygen Species/metabolism , Mice , DNA Repair , DNA Damage , Glutathione/metabolism , Glutathione/chemistry , Nucleic Acids/metabolism , Nucleic Acids/chemistry
12.
Anal Chim Acta ; 1309: 342677, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772666

ABSTRACT

BACKGROUND: Rapid and sensitive detection for acetamiprid, a kind of widely used neonicotinoid insecticide, is very meaningful for the development of modern agriculture and the protection of human health. Highly stable electrochemiluminescence (ECL) materials are one of the key factors in ECL sensing technology. ECL materials prepared by porous materials (e.g., MOFs) coated with chromophores have been used for ECL sensing detection, but these materials have poor stability because the chromophores escape when they are in aqueous solution. Therefore, the development of highly stable ECL materials is of great significance to improve the sensitivity of ECL sensing technology. RESULTS: In this work, by combining etched metal-organic frameworks (E-UIO-66-NH2) as carrier with Tris(4,4'-dicarboxylic acid-2,2'-bipyridine)Ru(II) chloride (Ru(dcbpy)32+) as signal probe via amide bonds, highly stable nanocomposites (E-UIO-66-NH2-Ru) with excellent ECL performance were firstly prepared. Then, using MoS2 loaded with AuNPs as substrate material and co-reactant promoter, a signal off-on-off ECL aptamer sensor was prepared for sensitive detection of acetamiprid. Due to the excellent catalytic activity of E-UIO-66-NH2-Ru and MoS2@Au towards K2S2O8, the ECL signals can be enhanced by multiple signal enhancement pathways, the prepared ECL aptamer sensor could achieve sensitive detection of acetamiprid in the linear range of 10-13 to10-7 mol L-1, with the limit of detection (LOD) of 2.78ⅹ10-15 mol L-1 (S/N = 3). After the evaluation of actual sample testing, this sensing platform was proven to be an effective method for the detection of acetamiprid in food and agricultural products. SIGNIFICANCE AND NOVELTY: The E-UIO-66-NH2-Ru prepared by linking Ru(dcbpy)32+ to E-UIO-66-NH2 via amide bonding has very high stability. The synergistic catalytic effect of MoS2 and AuNPs enhanced the ECL signal. By exploring the sensing mechanism and evaluating the actual sample tests, the proposed signal "on-off" ECL sensing strategy was proved to be an effective and excellent ECL sensing method for sensitive and stable detection of acetamiprid.


Subject(s)
Aptamers, Nucleotide , Electrochemical Techniques , Luminescent Measurements , Metal-Organic Frameworks , Neonicotinoids , Neonicotinoids/analysis , Electrochemical Techniques/methods , Aptamers, Nucleotide/chemistry , Luminescent Measurements/methods , Metal-Organic Frameworks/chemistry , Ruthenium/chemistry , Biosensing Techniques/methods , Limit of Detection , Coordination Complexes/chemistry , Insecticides/analysis
13.
Anal Chim Acta ; 1309: 342685, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772667

ABSTRACT

The monitoring of heavy metal ions in ocean is crucial for environment protection and assessment of seawater quality. However, the detection of heavy metal ions in seawater with electrochemical sensors, especially for long-term monitoring, always faces challenges due to marine biofouling caused by the nonspecific adsorption of microbial and biomolecules. Herein, an electrochemical aptasensor, integrating both antifouling and antibacterial properties, was developed for the detection of Hg2+ in the ocean. In this electrochemical aptasensor, eco-friendly peptides with superior hydrophilicity served as anti-biofouling materials, preventing nonspecific adsorption on the sensing interface, while silver nanoparticles were employed to eliminate bacteria. Subsequently, a ferrocene-modified aptamer was employed for the specific recognition of Hg2+, leveraging the aptamer's ability to fold into a thymine-Hg2+-thymine (T-Hg2+-T) structure upon interaction, and bringing ferrocene nearer to the sensor surface, significantly amplifying the electrochemical response. The prepared electrochemical aptasensor significantly reduced the nonspecific adsorption in seawater while maintaining sensitive electrochemical response. Furthermore, the biosensor exhibited a linear response range of 0.01-100 nM with a detection limit of 2.30 pM, and realized the accurate monitoring of mercury ions in real marine environment. The research results offer new insights into the preparation of marine antifouling sensing devices, and it is expected that sensors with antifouling and antimicrobial capabilities will find broad applications in the monitoring of marine pollutants.


Subject(s)
Anti-Bacterial Agents , Biofouling , Biosensing Techniques , Electrochemical Techniques , Mercury , Seawater , Mercury/analysis , Seawater/chemistry , Seawater/microbiology , Electrochemical Techniques/methods , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/pharmacology , Biosensing Techniques/methods , Biofouling/prevention & control , Aptamers, Nucleotide/chemistry , Silver/chemistry , Water Pollutants, Chemical/analysis , Metal Nanoparticles/chemistry , Limit of Detection , Ferrous Compounds/chemistry , Metallocenes
14.
Sci Rep ; 14(1): 11345, 2024 05 18.
Article in English | MEDLINE | ID: mdl-38762575

ABSTRACT

Staphylococcal enterotoxin A (SEA) is the most frequently reported in staphylococcal food poisoning (SFP) outbreaks. Aptamers are single-stranded nucleic acids that are seen as promising alternatives to antibodies in several areas, including diagnostics. In this work, systematic evolution of ligands by exponential enrichment (SELEX) was used to select DNA aptamers against SEA. The SELEX protocol employed magnetic beads as an immobilization matrix for the target molecule and real-time quantitative PCR (qPCR) for monitoring and optimizing sequence enrichment. After 10 selection cycles, the ssDNA pool with the highest affinity was sequenced by next generation sequencing (NGS). Approximately 3 million aptamer candidates were identified, and the most representative cluster sequences were selected for further characterization. The aptamer with the highest affinity showed an experimental dissociation constant (KD) of 13.36 ± 18.62 nM. Increased temperature negatively affected the affinity of the aptamer for the target. Application of the selected aptamers in a lateral flow assay demonstrated their functionality in detecting samples containing 100 ng SEA, the minimum amount capable of causing food poisoning. Overall, the applicability of DNA aptamers in SEA recognition was demonstrated and characterized under different conditions, paving the way for the development of diagnostic tools.


Subject(s)
Aptamers, Nucleotide , Enterotoxins , SELEX Aptamer Technique , Enterotoxins/genetics , Aptamers, Nucleotide/chemistry , SELEX Aptamer Technique/methods , Staphylococcal Food Poisoning/diagnosis , Staphylococcal Food Poisoning/microbiology , Humans , High-Throughput Nucleotide Sequencing , DNA, Single-Stranded
15.
Compr Rev Food Sci Food Saf ; 23(3): e13369, 2024 May.
Article in English | MEDLINE | ID: mdl-38767851

ABSTRACT

Mycotoxins, highly toxic and carcinogenic secondary metabolites produced by certain fungi, pose significant health risks as they contaminate food and feed products globally. Current mycotoxin detection methods have limitations in real-time detection capabilities. Aptasensors, incorporating aptamers as specific recognition elements, are crucial for mycotoxin detection due to their remarkable sensitivity and selectivity in identifying target mycotoxins. The sensitivity of aptasensors can be improved by using upconversion nanoparticles (UCNPs). UCNPs consist of lanthanide ions in ceramic host, and their ladder-like energy levels at f-orbitals have unique photophysical properties, including converting low-energy photons to high-energy emissions by a series of complex processes and offering sharp, low-noise, and sensitive near-infrared to visible detection strategy to enhance the efficacy of aptasensors for novel mycotoxin detection. This article aims to review recent reports on the scope of the potential of UCNPs in mycotoxin detection, focusing on their integration with aptasensors to give readers clear insight. We briefly describe the upconversion photoluminescence (UCPL) mechanism and relevant energy transfer processes influencing UCNP design and optimization. Furthermore, recent studies and advancements in UCNP-based aptasensors will be reviewed. We then discuss the potential impact of UCNP-modified aptasensors on food safety and present an outlook on future directions and challenges in this field. This review article comprehensively explains the current state-of-the-art UCNP-based aptasensors for mycotoxin detection. It provides insights into potential applications by addressing technical and practical challenges for practical implementation.


Subject(s)
Food Contamination , Food Safety , Mycotoxins , Nanoparticles , Mycotoxins/analysis , Mycotoxins/chemistry , Nanoparticles/chemistry , Food Contamination/analysis , Food Safety/methods , Aptamers, Nucleotide/chemistry , Food Quality , Biosensing Techniques/methods
16.
Anal Methods ; 16(19): 3088-3098, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38690679

ABSTRACT

Herein, a novel fluorescent/colorimetric/photothermal biosensor is proposed for aflatoxin B1 (AFB1) detection in food based on Prussian blue nanoparticles (PBNPs) (∼50 nm), gold nanoclusters (AuNCs), and an aptamer (Apt) within three hours. Briefly, a multifunctional compound, namely PBNPs-PEI@AuNCs, was synthesized from PBNPs as the loading carrier, polyethyleneimine (PEI) as the cross-linking agent, and AuNCs directly combined on the surface of PBNPs. The AFB1 Apt was then modified on the PBNPs-PEI@AuNCs to form a PBNPs-PEI@AuNCs-Apt probe, whereby when AFB1 is present, AFB1 is specifically captured by the probe. Meanwhile, the MNPs@antibody was also introduced to capture AFB1, thereby forming a "sandwich" structure compound. After magnetic separation, high temperature was applied to this "sandwich" structure compound to induce the denaturation of the Apt. Then the fluorescent/colorimetric/photothermal signals were collected from the PBNPs-PEI@AuNCs@Apt to give information on its related condition. The detection limits of the biosensor were 0.64 × 10-14, 0.96 × 10-14, and 0.55 × 10-12 g mL-1 for the three signals, which were outputted independently and could be verified with each other to ensure the accuracy of the results. Moreover, the colorimetric and photothermal strategies with this probe do not require large-scale instruments, providing a promising choice for achieving the rapid field detection of AFB1.


Subject(s)
Aflatoxin B1 , Biosensing Techniques , Ferrocyanides , Gold , Metal Nanoparticles , Aflatoxin B1/analysis , Aflatoxin B1/chemistry , Gold/chemistry , Biosensing Techniques/methods , Ferrocyanides/chemistry , Metal Nanoparticles/chemistry , Aptamers, Nucleotide/chemistry , Limit of Detection , Colorimetry/methods , Food Contamination/analysis , Polyethyleneimine/chemistry
17.
Bioconjug Chem ; 35(5): 674-681, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38695582

ABSTRACT

Aptamers are widely used molecular recognition tools in targeted therapy, but their ability to effectively penetrate deep into solid tumors remains a significant challenge, leading to suboptimal treatment efficacy. Here, we developed a polyfluoroalkyl (PFA) decoration strategy to enhance aptamer recognition, cell internalization, and solid tumor penetration. Our results indicate that PFA with around 11 fluorine atoms significantly improves aptamer internalization both in vitro and in vivo settings. However, we also observed that the use of PFA tags containing 19 and 23 fluorine atoms on aptamers resulted in nonspecific cell anchoring in control cell lines, affecting the specificity of aptamers. Overall, we found that using a chemical modification strategy could enhance the deep tumor penetration ability of aptamers and validate their effectiveness in vivo. This approach has significant practical applications in targeted drug delivery for cancer treatment.


Subject(s)
Aptamers, Nucleotide , Receptor Protein-Tyrosine Kinases , Aptamers, Nucleotide/chemistry , Humans , Animals , Receptor Protein-Tyrosine Kinases/antagonists & inhibitors , Receptor Protein-Tyrosine Kinases/metabolism , Cell Line, Tumor , Mice , Cell Adhesion Molecules/metabolism , Cell Adhesion Molecules/antagonists & inhibitors , Neoplasms/drug therapy , Neoplasms/metabolism , Drug Delivery Systems/methods
18.
J Nanobiotechnology ; 22(1): 243, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735927

ABSTRACT

Hepatocellular carcinoma (HCC) represents one of the deadliest cancers globally, making the search for more effective diagnostic and therapeutic approaches particularly crucial. Aptamer-functionalized nanomaterials (AFNs), an innovative nanotechnology, have paved new pathways for the targeted diagnosis and treatment of HCC. Initially, we outline the epidemiological background of HCC and the current therapeutic challenges. Subsequently, we explore in detail how AFNs enhance diagnostic and therapeutic efficiency and reduce side effects through the specific targeting of HCC cells and the optimization of drug delivery. Furthermore, we address the challenges faced by AFNs in clinical applications and future research directions, with a particular focus on enhancing their biocompatibility and assessing long-term effects. In summary, AFNs represent an avant-garde therapeutic approach, opening new avenues and possibilities for the diagnosis and treatment of HCC.


Subject(s)
Aptamers, Nucleotide , Carcinoma, Hepatocellular , Liver Neoplasms , Nanostructures , Carcinoma, Hepatocellular/drug therapy , Liver Neoplasms/drug therapy , Humans , Aptamers, Nucleotide/chemistry , Nanostructures/chemistry , Nanostructures/therapeutic use , Animals , Drug Delivery Systems/methods , Antineoplastic Agents/therapeutic use , Antineoplastic Agents/pharmacology
19.
Anal Chim Acta ; 1307: 342626, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38719405

ABSTRACT

BACKGROUND: C-reactive protein (CRP) represents an early clinical biomarker that indicates the presence of inflammatory or infectious conditions in the human body. Today's procedures approved by the Food and Drug Administration (FDA) imply expensive equipment and highly trained personnel to perform the test. Therefore, a new diagnostic method with high detection efficiency and less cost is urgently needed for delivering rapid and timely results in point-of-care (POC) service. RESULTS: Herein, we propose a new, equipment-free, and portable sensing method for the future POC detection of CRP based on the Tyndall effect (TE). In our study, aptamer-conjugated citrate-stabilized gold nanoparticles (apta-AuNPs) are exploited as the sensing platform. The apta-AuNPs' interaction with CRP in a saline environment leads to their aggregation, thus enhancing the scattering of light when the solution is exposed to a 640 nm pointer laser line. Firstly, the enhancement of the scattering light as a function of increasing concentration of CRP in solution is measured spectroscopically using a typical 90-degree angle spectrofluorometer and then the measurements are compared to the classic colorimetric detection using an UV-Vis spectrophotometer. Finally, to achieve high portability and accessibility, we demonstrate that the measurement of CRP concentration can be performed with similar accuracy but in a more direct and inexpensive way by using a laser pointer pen as the excitation source and a camera of a low-budget smartphone as a quantitative reader instead of most expensive spectrofluorometer. SIGNIFICANCE: The portable TE-based assay exhibits a wide linear dynamic range (1-60 µg/mL) for the detection of CRP with a limit of detection (LOD) of 92 ng/mL The proposed method is capable to integrate both standard and high-sensitivity CRP analysis in a single procedure with increased sensitivity and prompt delivery of analysis results. Moreover, the sensing procedure is significantly faster than the FDA approved ones with a detection time of only 10 min. Finally, as a proof-of-concept, our findings demonstrate excellent recovery for CRP detection in spiked and diluted urine samples, highlighting the strong potential of this sensing method for POC applications.


Subject(s)
Aptamers, Nucleotide , C-Reactive Protein , Gold , Metal Nanoparticles , Gold/chemistry , Metal Nanoparticles/chemistry , C-Reactive Protein/analysis , Aptamers, Nucleotide/chemistry , Humans , Biosensing Techniques , Limit of Detection , Colorimetry , Point-of-Care Systems
20.
Nat Commun ; 15(1): 3977, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730234

ABSTRACT

Potent and selective inhibition of the structurally homologous proteases of coagulation poses challenges for drug development. Hematophagous organisms frequently accomplish this by fashioning peptide inhibitors combining exosite and active site binding motifs. Inspired by this biological strategy, we create several EXACT inhibitors targeting thrombin and factor Xa de novo by linking EXosite-binding aptamers with small molecule ACTive site inhibitors. The aptamer component within the EXACT inhibitor (1) synergizes with and enhances the potency of small-molecule active site inhibitors by many hundred-fold (2) can redirect an active site inhibitor's selectivity towards a different protease, and (3) enable efficient reversal of inhibition by an antidote that disrupts bivalent binding. One EXACT inhibitor, HD22-7A-DAB, demonstrates extraordinary anticoagulation activity, exhibiting great potential as a potent, rapid onset anticoagulant to support cardiovascular surgeries. Using this generalizable molecular engineering strategy, selective, potent, and rapidly reversible EXACT inhibitors can be created against many enzymes through simple oligonucleotide conjugation for numerous research and therapeutic applications.


Subject(s)
Aptamers, Nucleotide , Catalytic Domain , Hirudins , Thrombin , Humans , Aptamers, Nucleotide/chemistry , Aptamers, Nucleotide/pharmacology , Thrombin/antagonists & inhibitors , Thrombin/metabolism , Thrombin/chemistry , Hirudins/chemistry , Hirudins/pharmacology , Anticoagulants/pharmacology , Anticoagulants/chemistry , Factor Xa/metabolism , Factor Xa/chemistry , Factor Xa Inhibitors/chemistry , Factor Xa Inhibitors/pharmacology , Animals , Binding Sites , Blood Coagulation/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL
...