Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 13.268
Filter
2.
Sci Rep ; 14(1): 12823, 2024 06 04.
Article in English | MEDLINE | ID: mdl-38834839

ABSTRACT

The prevalence of cardiovascular disease (CVD) has surged in recent years, making it the foremost cause of mortality among humans. The Electrocardiogram (ECG), being one of the pivotal diagnostic tools for cardiovascular diseases, is increasingly gaining prominence in the field of machine learning. However, prevailing neural network models frequently disregard the spatial dimension features inherent in ECG signals. In this paper, we propose an ECG autoencoder network architecture incorporating low-rank attention (LRA-autoencoder). It is designed to capture potential spatial features of ECG signals by interpreting the signals from a spatial perspective and extracting correlations between different signal points. Additionally, the low-rank attention block (LRA-block) obtains spatial features of electrocardiogram signals through singular value decomposition, and then assigns these spatial features as weights to the electrocardiogram signals, thereby enhancing the differentiation of features among different categories. Finally, we utilize the ResNet-18 network classifier to assess the performance of the LRA-autoencoder on both the MIT-BIH Arrhythmia and PhysioNet Challenge 2017 datasets. The experimental results reveal that the proposed method demonstrates superior classification performance. The mean accuracy on the MIT-BIH Arrhythmia dataset is as high as 0.997, and the mean accuracy and F 1 -score on the PhysioNet Challenge 2017 dataset are 0.850 and 0.843.


Subject(s)
Electrocardiography , Neural Networks, Computer , Electrocardiography/methods , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Machine Learning , Signal Processing, Computer-Assisted , Algorithms , Cardiovascular Diseases/diagnosis
3.
BMJ Open ; 14(6): e075110, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38830741

ABSTRACT

INTRODUCTION: Screening for atrial fibrillation (AF) in the general population may help identify individuals at risk, enabling further assessment of risk factors and institution of appropriate treatment. Algorithms deployed on wearable technologies such as smartwatches and fitness bands may be trained to screen for such arrhythmias. However, their performance needs to be assessed for safety and accuracy prior to wide-scale implementation. METHODS AND ANALYSIS: This study will assess the ability of the WHOOP strap to detect AF using its WHOOP Arrhythmia Notification Feature (WARN) algorithm in an enriched cohort with a 2:1 distribution of previously diagnosed AF (persistent and paroxysmal) and healthy controls. Recruited participants will collect data for 7 days with the WHOOP wrist-strap and BioTel ePatch (electrocardiography gold-standard). Primary outcome will be participant level sensitivity and specificity of the WARN algorithm in detecting AF in analysable windows compared with the ECG gold-standard. Similar analyses will be performed on an available epoch-level basis as well as comparison of these findings in important subgroups. ETHICS AND DISSEMINATION: The study was approved by the ethics board at the study site. Participants will be enrolled after signing an online informed consent document. Updates will be shared via clinicaltrials.gov. The data obtained from the conclusion of this study will be presented in national and international conferences with publication in clinical research journals. TRIAL REGISTRATION NUMBER: NCT05809362.


Subject(s)
Algorithms , Atrial Fibrillation , Wearable Electronic Devices , Humans , Atrial Fibrillation/diagnosis , Electrocardiography , Male , Female , Observational Studies as Topic , Middle Aged , Adult , Arrhythmias, Cardiac/diagnosis
4.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38848447

ABSTRACT

Pulsed field ablation (PFA) is an innovative approach in the field of cardiac electrophysiology aimed at treating cardiac arrhythmias. Unlike traditional catheter ablation energies, which use radiofrequency or cryothermal energy to create lesions in the heart, PFA utilizes pulsed electric fields to induce irreversible electroporation, leading to targeted tissue destruction. This state-of-the-art review summarizes biophysical principles and clinical applications of PFA, highlighting its potential advantages over conventional ablation methods. Clinical data of contemporary PFA devices are discussed, which combine predictable procedural outcomes and a reduced risk of thermal collateral damage. Overall, these technological developments have propelled the rapid evolution of contemporary PFA catheters, with future advancements potentially impacting patient care.


Subject(s)
Arrhythmias, Cardiac , Humans , Arrhythmias, Cardiac/surgery , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Electroporation/trends , Electroporation/methods , Treatment Outcome , Forecasting , Catheter Ablation/trends , Catheter Ablation/methods , Ablation Techniques/trends , Cardiac Catheters , Animals
5.
Neurology ; 103(1): e209501, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38870452

ABSTRACT

BACKGROUND AND OBJECTIVES: Generalized convulsive seizures (GCSs) are the main risk factor of sudden unexpected death in epilepsy (SUDEP), which is likely due to peri-ictal cardiorespiratory dysfunction. The incidence of GCS-induced cardiac arrhythmias, their relationship to seizure severity markers, and their role in SUDEP physiopathology are unknown. The aim of this study was to analyze the incidence of seizure-induced cardiac arrhythmias, their association with electroclinical features and seizure severity biomarkers, as well as their specific occurrences in SUDEP cases. METHODS: This is an observational, prospective, multicenter study of patients with epilepsy aged 18 years and older with recorded GCS during inpatient video-EEG monitoring for epilepsy evaluation. Exclusion criteria were status epilepticus and an obscured video recording. We analyzed semiologic and cardiorespiratory features through video-EEG (VEEG), electrocardiogram, thoracoabdominal bands, and pulse oximetry. We investigated the presence of bradycardia, asystole, supraventricular tachyarrhythmias (SVTs), premature atrial beats, premature ventricular beats, nonsustained ventricular tachycardia (NSVT), atrial fibrillation (Afib), ventricular fibrillation (VF), atrioventricular block (AVB), exaggerated sinus arrhythmia (ESA), and exaggerated sinus arrhythmia with bradycardia (ESAWB). A board-certified cardiac electrophysiologist diagnosed and classified the arrhythmia types. Bradycardia, asystole, SVT, NSVT, Afib, VF, AVB, and ESAWB were classified as arrhythmias of interest because these were of SUDEP pathophysiology value. The main outcome was the occurrence of seizure-induced arrhythmias of interest during inpatient VEEG monitoring. Moreover, yearly follow-up was conducted to identify SUDEP cases. Binary logistic generalized estimating equations were used to determine clinical-demographic and peri-ictal variables that were predictive of the presence of seizure-induced arrhythmias of interest. The z-score test for 2 population proportions was used to test whether the proportion of seizures and patients with postconvulsive ESAWB or bradycardia differed between SUDEP cases and survivors. RESULTS: This study includes data from 249 patients (mean age 37.2 ± 23.5 years, 55% female) who had 455 seizures. The most common arrhythmia was ESA, with an incidence of 137 of 382 seizures (35.9%) (106/224 patients [47.3%]). There were 50 of 352 seizure-induced arrhythmias of interest (14.2%) in 41 of 204 patients (20.1%). ESAWB was the commonest in 22 of 394 seizures (5.6%) (18/225 patients [8%]), followed by SVT in 18 of 397 seizures (4.5%) (17/228 patients [7.5%]). During follow-up (48.36 ± 31.34 months), 8 SUDEPs occurred. Seizure-induced bradycardia (3.8% vs 12.5%, z = -16.66, p < 0.01) and ESAWB (6.6% vs 25%; z = -3.03, p < 0.01) were over-represented in patients who later died of SUDEP. There was no association between arrhythmias of interest and seizure severity biomarkers (p > 0.05). DISCUSSION: Markers of seizure severity are not related to seizure-induced arrhythmias of interest, suggesting that other factors such as occult cardiac abnormalities may be relevant for their occurrence. Seizure-induced ESAWB and bradycardia were more frequent in SUDEP cases, although this observation was based on a very limited number of SUDEP patients. Further case-control studies are needed to evaluate the yield of arrhythmias of interest along with respiratory changes as potential SUDEP biomarkers.


Subject(s)
Arrhythmias, Cardiac , Electroencephalography , Humans , Female , Male , Adult , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Incidence , Middle Aged , Prospective Studies , Sudden Unexpected Death in Epilepsy/epidemiology , Seizures/epidemiology , Seizures/physiopathology , Epilepsy, Generalized/epidemiology , Epilepsy, Generalized/physiopathology , Aged , Young Adult , Electrocardiography , Adolescent
6.
Math Biosci Eng ; 21(4): 5521-5535, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38872546

ABSTRACT

Early diagnosis of abnormal electrocardiogram (ECG) signals can provide useful information for the prevention and detection of arrhythmia diseases. Due to the similarities in Normal beat (N) and Supraventricular Premature Beat (S) categories and imbalance of ECG categories, arrhythmia classification cannot achieve satisfactory classification results under the inter-patient assessment paradigm. In this paper, a multi-path parallel deep convolutional neural network was proposed for arrhythmia classification. Furthermore, a global average RR interval was introduced to address the issue of similarities between N vs. S categories, and a weighted loss function was developed to solve the imbalance problem using the dynamically adjusted weights based on the proportion of each class in the input batch. The MIT-BIH arrhythmia dataset was used to validate the classification performances of the proposed method. Experimental results under the intra-patient evaluation paradigm and inter-patient evaluation paradigm showed that the proposed method could achieve better classification results than other methods. Among them, the accuracy, average sensitivity, average precision, and average specificity under the intra-patient paradigm were 98.73%, 94.89%, 89.38%, and 98.24%, respectively. The accuracy, average sensitivity, average precision, and average specificity under the inter-patient paradigm were 91.22%, 89.91%, 68.23%, and 95.23%, respectively.


Subject(s)
Algorithms , Arrhythmias, Cardiac , Electrocardiography , Neural Networks, Computer , Signal Processing, Computer-Assisted , Humans , Arrhythmias, Cardiac/classification , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Electrocardiography/methods , Sensitivity and Specificity , Deep Learning , Reproducibility of Results , Databases, Factual
7.
Math Biosci Eng ; 21(4): 5863-5880, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38872562

ABSTRACT

Within the domain of cardiovascular diseases, arrhythmia is one of the leading anomalies causing sudden deaths. These anomalies, including arrhythmia, are detectable through the electrocardiogram, a pivotal component in the analysis of heart diseases. However, conventional methods like electrocardiography encounter challenges such as subjective analysis and limited monitoring duration. In this work, a novel hybrid model, AttBiLFNet, was proposed for precise arrhythmia detection in ECG signals, including imbalanced class distributions. AttBiLFNet integrates a Bidirectional Long Short-Term Memory (BiLSTM) network with a convolutional neural network (CNN) and incorporates an attention mechanism using the focal loss function. This architecture is capable of autonomously extracting features by harnessing BiLSTM's bidirectional information flow, which proves advantageous in capturing long-range dependencies. The attention mechanism enhances the model's focus on pertinent segments of the input sequence, which is particularly beneficial in class imbalance classification scenarios where minority class samples tend to be overshadowed. The focal loss function effectively addresses the impact of class imbalance, thereby improving overall classification performance. The proposed AttBiLFNet model achieved 99.55% accuracy and 98.52% precision. Moreover, performance metrics such as MF1, K score, and sensitivity were calculated, and the model was compared with various methods in the literature. Empirical evidence showed that AttBiLFNet outperformed other methods in terms of both accuracy and computational efficiency. The introduced model serves as a reliable tool for the timely identification of arrhythmias.


Subject(s)
Algorithms , Arrhythmias, Cardiac , Electrocardiography , Neural Networks, Computer , Signal Processing, Computer-Assisted , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Electrocardiography/methods , Reproducibility of Results
8.
PLoS One ; 19(6): e0303178, 2024.
Article in English | MEDLINE | ID: mdl-38870233

ABSTRACT

Accurate delineation of key waveforms in an ECG is a critical step in extracting relevant features to support the diagnosis and treatment of heart conditions. Although deep learning based methods using segmentation models to locate P, QRS, and T waves have shown promising results, their ability to handle arrhythmias has not been studied in any detail. In this paper we investigate the effect of arrhythmias on delineation quality and develop strategies to improve performance in such cases. We introduce a U-Net-like segmentation model for ECG delineation with a particular focus on diverse arrhythmias. This is followed by a post-processing algorithm which removes noise and automatically determines the boundaries of P, QRS, and T waves. Our model has been trained on a diverse dataset and evaluated against the LUDB and QTDB datasets to show strong performance, with F1-scores exceeding 99% for QRS and T waves, and over 97% for P waves in the LUDB dataset. Furthermore, we assess various models across a wide array of arrhythmias and observe that models with a strong performance on standard benchmarks may still perform poorly on arrhythmias that are underrepresented in these benchmarks, such as tachycardias. We propose solutions to address this discrepancy.


Subject(s)
Algorithms , Arrhythmias, Cardiac , Deep Learning , Electrocardiography , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Electrocardiography/methods , Signal Processing, Computer-Assisted
10.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38866455

ABSTRACT

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Heart Valve Prosthesis , Pacemaker, Artificial , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aged , Time Factors , Aged, 80 and over , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , United States/epidemiology
12.
Adv Exp Med Biol ; 1441: 1023-1031, 2024.
Article in English | MEDLINE | ID: mdl-38884767

ABSTRACT

The electrocardiogram (ECG) is one of the cornerstones of diagnostic investigations in pediatric or adult cardiology. The standard ECG includes 12 leads; there are 6 leads that are derived from electrodes from the arms and legs (Einthoven and Goldberger leads) and 6 precordial leads (Wilson leads).


Subject(s)
Arrhythmias, Cardiac , Electrocardiography , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Electrocardiography/methods , Child , Adult
13.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38804218

ABSTRACT

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Electrocardiography, Ambulatory , Primary Prevention , Humans , Primary Prevention/methods , Male , Female , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Middle Aged , Aged , Prospective Studies , Electrocardiography, Ambulatory/methods , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Assessment/methods , Risk Factors , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/prevention & control , Arrhythmias, Cardiac/mortality , Treatment Outcome , Predictive Value of Tests , Time Factors , Europe/epidemiology , Prognosis , Heart Rate/physiology
14.
Turk J Haematol ; 41(2): 91-96, 2024 05 30.
Article in English | MEDLINE | ID: mdl-38721568

ABSTRACT

Objective: Bruton tyrosine kinase inhibition in cardiac tissue causes inhibition of the PI3K-AKT signaling pathway, which is responsible for protecting cardiac tissue during stress. Therefore, there is an increase in the risk of arrhythmia. This study explores the prediction of that risk with the Age-Creatinine-Ejection Fraction (ACEF) score as a simple scoring system based on the components of age, creatinine, and ejection fraction. Materials and Methods: Patients diagnosed with chronic lymphocytic leukemia (CLL) and receiving ibrutinib treatment for at least 1 year were evaluated with echocardiography and Holter electrocardiography and the results were compared with a control group of CLL patients who had not received treatment. ACEF score was calculated with the formula age/left ventricular ejection fraction+1 (if creatinine >2.0 mg/dL). Results: When the arrhythmia development of the patients was evaluated, no statistically significant difference was found between the control and ibrutinib groups in terms of types of arrhythmias other than paroxysmal atrial fibrillation (PAF). PAF was found to occur at rates of 8% versus 22% (p=0.042) among ibrutinib non-users versus users. For patients using ibrutinib, an ACEF score of >1.21 predicted the development of PAF with 77% sensitivity and 75% specificity (area under the curve: 0.830, 95% confidence interval: 0.698-0.962, p<0.001). Conclusion: The ACEF score can be used as a risk score that predicts the development of PAF in patients diagnosed with CLL who are scheduled to start ibrutinib.


Subject(s)
Adenine , Arrhythmias, Cardiac , Leukemia, Lymphocytic, Chronic, B-Cell , Piperidines , Humans , Leukemia, Lymphocytic, Chronic, B-Cell/drug therapy , Leukemia, Lymphocytic, Chronic, B-Cell/diagnosis , Adenine/analogs & derivatives , Adenine/adverse effects , Piperidines/therapeutic use , Piperidines/adverse effects , Male , Female , Aged , Middle Aged , Arrhythmias, Cardiac/chemically induced , Arrhythmias, Cardiac/diagnosis , Creatinine/blood , Pyrimidines/adverse effects , Pyrimidines/therapeutic use , Aged, 80 and over , Protein Kinase Inhibitors/adverse effects , Protein Kinase Inhibitors/therapeutic use
15.
Card Electrophysiol Clin ; 16(2): 195-202, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749641

ABSTRACT

The case series reviews differential diagnosis of a genetic arrhythmia syndrome when evaluating a patient with prolonged QTc. Making the correct diagnosis requires: detailed patient history, family history, and careful review of the electrocardiogram (ECG). Signs and symptoms and ECG characteristics can often help clinicians make the diagnosis before genetic testing results return. These skills can help clinicians make an accurate and timely diagnosis and prevent life-threatening events.


Subject(s)
Arrhythmias, Cardiac , Electrocardiography , Long QT Syndrome , Humans , Diagnosis, Differential , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/physiopathology , Long QT Syndrome/diagnosis , Long QT Syndrome/genetics , Long QT Syndrome/physiopathology , Child , Male , Female , Adolescent , Genetic Testing
16.
Card Electrophysiol Clin ; 16(2): 211-218, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749643

ABSTRACT

The following case series presents three different pediatric patients with SCN5A-related disease. In addition, family members are presented to demonstrate the variable penetrance that is commonly seen. Identifying features of this disease is important, because even in the very young, SCN5A disorders can cause lethal arrhythmias and sudden death.


Subject(s)
Arrhythmias, Cardiac , Long QT Syndrome , NAV1.5 Voltage-Gated Sodium Channel , Humans , NAV1.5 Voltage-Gated Sodium Channel/genetics , Long QT Syndrome/genetics , Long QT Syndrome/physiopathology , Male , Female , Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Child , Electrocardiography , Child, Preschool , Adolescent , Infant
18.
Int J Cardiol ; 409: 132167, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38797198

ABSTRACT

AIMS: The prediction of ventricular arrhythmia (VA) in hypertrophic cardiomyopathy (HCM) remains challenging. We sought to characterize the VA risk profile in HCM patients through clustering analysis combining clinical and conventional imaging parameters with information derived from left ventricular longitudinal strain analysis (LV-LS). METHODS: A total of 434 HCM patients (65% men, mean age 56 years) were included from two referral centers and followed longitudinally (mean duration 6 years). Mechanical and temporal parameters were automatically extracted from the LV-LS segmental curves of each patient in addition to conventional clinical and imaging data. A total of 287 features were analyzed using a clustering approach (k-means). The principal endpoint was VA. RESULTS: 4 clusters were identified with a higher rhythmic risk for clusters 1 and 4 (VA rates of 26%(28/108), 13%(13/97), 12%(14/120), and 31%(34/109) for cluster 1,2,3 and 4 respectively). These 4 clusters differed mainly by LV-mechanics with a severe and homogeneous decrease of myocardial deformation for cluster 4, a small decrease for clusters 2 and 3 and a marked deformation delay and temporal dispersion for cluster 1 associated with a moderate decrease of the GLS (p < 0.0001 for GLS comparison between clusters). Patients from cluster 4 had the most severe phenotype (mean LV mass index 123 vs. 112 g/m2; p = 0.0003) with LV and left atrium (LA) remodeling (LA-volume index (LAVI) 46.6 vs. 41.5 ml/m2, p = 0.04 and LVEF 59.7 vs. 66.3%, p < 0.001) and impaired exercise capacity (% predicted peak VO2 58.6 vs. 69.5%; p = 0.025). CONCLUSION: Processing LV-LS parameters in HCM patients 4 clusters with specific LV-strain patterns and different rhythmic risk levels are identified. Automatic extraction and analysis of LV strain parameters improves the risk stratification for VA in HCM patients.


Subject(s)
Cardiomyopathy, Hypertrophic , Humans , Male , Middle Aged , Female , Cardiomyopathy, Hypertrophic/physiopathology , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cluster Analysis , Aged , Adult , Follow-Up Studies , Risk Factors , Echocardiography/methods , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Ventricular Function, Left/physiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/diagnostic imaging , Longitudinal Studies , Risk Assessment/methods
19.
Pacing Clin Electrophysiol ; 47(6): 789-801, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38712484

ABSTRACT

The rapid growth in computational power, sensor technology, and wearable devices has provided a solid foundation for all aspects of cardiac arrhythmia care. Artificial intelligence (AI) has been instrumental in bringing about significant changes in the prevention, risk assessment, diagnosis, and treatment of arrhythmia. This review examines the current state of AI in the diagnosis and treatment of atrial fibrillation, supraventricular arrhythmia, ventricular arrhythmia, hereditary channelopathies, and cardiac pacing. Furthermore, ChatGPT, which has gained attention recently, is addressed in this paper along with its potential applications in the field of arrhythmia. Additionally, the accuracy of arrhythmia diagnosis can be improved by identifying electrode misplacement or erroneous swapping of electrode position using AI. Remote monitoring has expanded greatly due to the emergence of contactless monitoring technology as wearable devices continue to develop and flourish. Parallel advances in AI computing power, ChatGPT, availability of large data sets, and more have greatly expanded applications in arrhythmia diagnosis, risk assessment, and treatment. More precise algorithms based on big data, personalized risk assessment, telemedicine and mobile health, smart hardware and wearables, and the exploration of rare or complex types of arrhythmia are the future direction.


Subject(s)
Arrhythmias, Cardiac , Artificial Intelligence , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Risk Assessment
20.
Pflugers Arch ; 476(7): 1145-1154, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38703193

ABSTRACT

Arrhythmia detection is essential when assessing the safety of novel drugs and therapies in preclinical studies. Many short-term arrhythmia monitoring methods exist, including non-invasive ECG and Holter. However, there are no reliable, long-term, non-invasive, or minimally invasive methods for cardiac arrhythmia follow-up in large animals that allows free movement with littermates. A long follow-up time is needed when estimating the impact of long-lasting drugs or therapies, such as gene therapy. We evaluated the feasibility and performance of insertable cardiac monitors (ICMs) in pigs for minimally invasive, long-term monitoring of cardiac arrhythmias that allows free movement and species-specific behavior. Multiple implantation sites were tested to assess signal quality. ICMs recognized reliably many different arrhythmias but failed to detect single extrasystoles. They also over-diagnosed T-waves, resulting in oversensing. Muscle activity and natural startles of the animals caused noise, leading to a heterogeneous signal requiring post-recording evaluation. In spite of these shortcomings, the ICMs showed to be very useful for minimally invasive long-term monitoring of cardiac rhythm in pigs.


Subject(s)
Arrhythmias, Cardiac , Animals , Swine , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Electrocardiography/methods , Electrocardiography/instrumentation , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Monitoring, Physiologic/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL
...