Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.545
Filter
1.
Sci Rep ; 14(1): 12643, 2024 06 02.
Article in English | MEDLINE | ID: mdl-38825602

ABSTRACT

This study compared the radiologic and clinical outcomes of a new seven-axis robotic-assisted total hip arthroplasty (THA) and conventional THA. Hundred and four patients were randomly assigned to two groups-the robotic-assisted THA group (RAS group) and the conventional THA group (CON group). The preoperative and postoperative Harris Hip score (HHS), acetabular inclination, anteversion, femoral offset, and leg length discrepancy (LLD) were compared. During the follow-up, no patients had any complications that could be associated with the use of the robot. The proportion of acetabular cups in the safety zone was significantly higher in the RAS group than that in the CON group. The two groups had significantly different mean absolute difference of inclination and anteversion. There was no significant difference in the postoperative HHSs, changes in HHSs, femoral offset, and lower limb length between the two groups. The seven-axis robotic-assisted THA system is safe and effective, and leads to better acetabulum cup positioning compared to conventional THA. The improvements observed in the HHS, LLD, and femoral offset in the RAS group were similar to those in the CON group.Clinical trial registration time: 19/05/2022.Clinical trial registration number: ChiCTR2200060115.


Subject(s)
Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Male , Female , Robotic Surgical Procedures/methods , Middle Aged , Prospective Studies , Aged , Treatment Outcome , Acetabulum/surgery
2.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38728525

ABSTRACT

CASE: Two patients with osteopetrosis underwent conversion total hip arthroplasty (THA) after failure of internal fixation due to hip fractures. We experienced challenges, including difficulty of hardware removal, remaining of previous broken screws in the canal, difficulty in finding the femoral canal, and an intraoperative acetabulum fracture. Despite complications, both patients achieved satisfactory functional outcome after surgery at the latest follow-up. CONCLUSION: Our cases showed that previous hip fracture and failed internal fixation make conversion THA more complex and unpredictable in patients with osteopetrosis. This in turn underscores the critical need for advanced preoperative planning, intraoperative flexibility, and meticulous postoperative care.


Subject(s)
Arthroplasty, Replacement, Hip , Osteopetrosis , Humans , Arthroplasty, Replacement, Hip/methods , Osteopetrosis/surgery , Osteopetrosis/complications , Female , Hip Fractures/surgery , Male , Middle Aged , Fracture Fixation, Internal/methods , Aged
3.
BMJ Open ; 14(5): e082243, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38719293

ABSTRACT

INTRODUCTION: The femoral head contralateral to the collapsed femoral head requiring total hip arthroplasty (THA) often manifests in the precollapse stage of osteonecrosis of the femoral head (ONFH). It is not yet demonstrated how autologous concentrated bone marrow injection may prevent collapse of the femoral head concurrent with contralateral THA. The primary objective is to evaluate the efficacy of autologous concentrated bone marrow injection for the contralateral, non-collapsed, femoral head in patients with bilateral ONFH, with the ipsilateral collapsed femoral head undergoing THA. METHODS AND ANALYSIS: This is a multicentre, prospective, non-randomised, historical-data controlled study. We will recruit patients with ONFH who are scheduled for THA and possess a non-collapsed contralateral femoral head. Autologous bone marrow will be collected using a point-of-care device. After concentration, the bone marrow will be injected into the non-collapsed femoral head following the completion of THA in the contralateral hip. The primary outcome is the percentage of femoral head collapse evaluated by an independent data monitoring committee using plain X-rays in two directions 2 years after autologous concentrated bone marrow injection. Postinjection safety, adverse events, pain and hip function will also be assessed. The patients will be evaluated preoperatively, and at 6 months, 1 year and 2 years postoperatively. ETHICS AND DISSEMINATION: This protocol has been approved by the Certified Committee for Regenerative Medicine of Tokyo Medical and Dental University and Japan's Ministry of Healthy, Labour and Welfare and will be performed as a class III regenerative medicine protocol, in accordance with Japan's Act on the Safety of Regenerative Medicine. The results of this study will be submitted to a peer-review journal for publication. The results of this study are expected to provide evidence to support the inclusion of autologous concentrated bone marrow injections in the non-collapsed femoral head in Japan's national insurance coverage. TRIAL REGISTRATION NUMBER: jRCTc032200229.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Marrow Transplantation , Femur Head Necrosis , Transplantation, Autologous , Humans , Femur Head Necrosis/surgery , Femur Head Necrosis/therapy , Arthroplasty, Replacement, Hip/methods , Prospective Studies , Bone Marrow Transplantation/methods , Adult , Multicenter Studies as Topic , Female , Male , Middle Aged , Non-Randomized Controlled Trials as Topic , Femur Head
4.
J Pak Med Assoc ; 74(4 (Supple-4)): S161-S164, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38712426

ABSTRACT

ChatGPT is reported to be an acceptable tool to answer a majority of frequently asked patient questions. ChatGPT also converses in other languages including Urdu, which offers immense potential for the education of Pakistani patients. Therefore, this study evaluated ChatGPT's Urdu answers to the ten most frequently asked questions on Total Hip Arthroplasty, which were then rated by an expert. Out of 10 answers in English, 9 (90%) were satisfactory requiring minimal clarification and 1 (10%) was satisfactory requiring moderate clarification. In both Roman and Nastaliq script Urdu, 1 (10%) answer was satisfactory requiring moderate clarification, while 9 (90%) were unsatisfactory requiring substantial clarification. In conclusion, as opposed to ChatGPT English responses, Urdu responses were much less rigorous, generic, and lacked scientific rigor. We have a long way to go before Pakistani patients with limited English language skills could benefit from AI chatbots like ChatGPT.


Subject(s)
Arthroplasty, Replacement, Hip , Artificial Intelligence , Humans , Arthroplasty, Replacement, Hip/methods , Pakistan , Language , Patient Education as Topic/methods , Surveys and Questionnaires
5.
Bull Hosp Jt Dis (2013) ; 82(2): 134-138, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38739661

ABSTRACT

BACKGROUND: As volume of total hip arthroplasty (THA) continues to increase, the utilization and availability of in-traoperative advanced technologies to arthroplasty surgeons continues to rise as well. Our primary goal was to determine whether the use of a mini navigation technology extended operative times and secondarily if it affected postoperative outcomes following elective THA. METHODS: A single-institution total joint arthroplasty da-tabase was utilized to identify adult patients who underwent elective THA from 2017 to 2019. Baseline demographic data along with surgical operative time, length of stay (LOS) and discharge disposition were collected. The Activity Measure for Post-Acute Care (AM-PAC) was used to determine physi-cal therapy progress. RESULTS: A total of 1,162 THAs were performed of which 69.1% (803) used navigation while 30.9% (359) did not. Baseline demographics including age, sex, body mass index (BMI), insurance, and smoking status were not statistically different between groups. The operative time was shorter in the navigation group compared to THA without navigation (115.1 vs. 118.9 min, p < 0.0001). Mean LOS was signifi-cantly shorter in the navigation THA group as compared to THA without navigation (2.1 vs. 2.6 days, p < 0.0001). Postoperative AM-PAC scores were higher in the navigation group on postoperative day 1 as compared to patients with-out navigation (18.87 vs. 17.52, p < 0.0001). Additionally, a greater percentage of patients were discharged directly home after THA with navigation as compared to THA without navigation (89.54% vs. 83.57%, p < 0.0001). CONCLUSION: Our study demonstrates that hip navigation technology in the setting of THA is associated with reduced operative times and higher AM-PAC mobilization scores. Hip mini navigation technology shortens operative times while improving early patient outcome scores in association with shorter LOS and greater home-based discharge.


Subject(s)
Arthroplasty, Replacement, Hip , Length of Stay , Operative Time , Patient Discharge , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/statistics & numerical data , Length of Stay/statistics & numerical data , Male , Female , Middle Aged , Aged , Patient Discharge/statistics & numerical data , Treatment Outcome , Retrospective Studies , Physical Therapy Modalities/statistics & numerical data , Recovery of Function
6.
Bull Hosp Jt Dis (2013) ; 82(2): 112-117, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38739658

ABSTRACT

BACKGROUND: The surgical approach used for arthroplasty in the setting of hip fracture has traditionally been decided based on surgeon preference. This study analyzed the ef-fect of the surgical approach on hospital quality measures, complications, and mortality in patients treated with hip arthroplasty for fracture fixation. METHODS: A cohort of consecutive acute hip fracture pa-tients who were 60 years of age or older and who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) at one academic medical center between January 2014 and January 2018 was included. Patient demographics, length of stay (LOS), surgery details, complications, ambulation at dis-charge, discharge location, readmission, and mortality were recorded. Two cohorts were included based on the surgical approach: the anterior-based cohort included the direct an-terior and anterolateral approaches and the posterior-based cohort included direct lateral and posterior approaches. RESULTS: Two hundred five patients were included: 146 underwent HA (81 anterior-based and 65 posterior-based) and 79 underwent THA (37 anterior-based and 42 posterior-based). The mean age of the HA and THA cohorts was 84.1 ± 7.5 and 73.7 ± 8.0 years, respectively. There was no dif-ference in LOS, time to surgery, or surgical time between the two cohorts for HA and THA. There were no differences in perioperative complications, including dislocation, ob-served based on surgical approach. No difference was found between readmission rates and mortality. CONCLUSION: In this cohort of hip fracture arthroplasty patients, there was no difference observed in hospital quality measures, readmission, or mortality in patients based on sur-gical approach. These results are in contrast with literature in elective arthroplasty patients supporting the use of an anterior approach for potential improved short-term outcomes.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hemiarthroplasty , Length of Stay , Postoperative Complications , Humans , Femoral Neck Fractures/surgery , Femoral Neck Fractures/mortality , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/adverse effects , Female , Aged , Male , Aged, 80 and over , Treatment Outcome , Postoperative Complications/etiology , Length of Stay/statistics & numerical data , Hemiarthroplasty/methods , Hemiarthroplasty/mortality , Hemiarthroplasty/adverse effects , Retrospective Studies , Patient Readmission/statistics & numerical data , Middle Aged
7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 576-582, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752244

ABSTRACT

Objective: To investigate the accuracy and effectiveness of acetabular cup placement in total hip arthroplasty (THA) after lumbar fusion applying of modified acetabular anteversion and inclination angles test system. Methods: A clinical data of 45 patients undergoing THA for osteoarthritis between January 2018 and June 2023 was retrospectively analyzed. All patients had previously received lumbar fusion. The modified acetabular anteversion and inclination angle test system was used in 26 cases (observation group) and not used in 19 cases (control group) during THA. There was no significant difference in baseline data such as gender, age, body mass index, operative side, number of lumbar fusion segments, and preoperative Harris score between the two groups ( P>0.05). The position of acetabular prosthesis, hip function (Harris score), and incidence of complications were compared between the two groups. Results: In the observation group, all acetabular cups were in the safe zone (anteversion angle, 25°-30°) during operation, and 1 acetabular cup (3.85%) was not in the safe zone after operation. In the control group, 9 acetabular cups (47.37%) were not in the safe zone. The postoperative difference between the two groups was significant ( P<0.05). There was no significant difference between intra- and post-operative acetabular inclination angles in the observation group ( P>0.05), and the postoperative acetabular inclination angle was significantly smaller in the observation group than in the control group ( P<0.05). All incisions healed by first intention and no infection occurred. All patients were followed up 6 months. There was no significant difference in Harris score between the two groups at different time point ( P>0.05), and there were significant differences between different time points in the two groups ( P<0.05). No joint dislocation occurred in the observation group during follow-up, while dislocation occurred in 2 cases and femoral impingement syndrome occurred in 1 case of the control group. There was no significant difference in the incidence of complications between the two groups ( P>0.05). Conclusion: For THA patients with lumbar fusion, the ideal placement angle of the acetabular cup can be obtained by using the modified acetabular anteversion and inclination angles test system during operation.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Lumbar Vertebrae , Spinal Fusion , Humans , Arthroplasty, Replacement, Hip/methods , Acetabulum/surgery , Spinal Fusion/methods , Retrospective Studies , Male , Female , Lumbar Vertebrae/surgery , Postoperative Complications/prevention & control , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome , Hip Prosthesis , Middle Aged , Osteoarthritis, Hip/surgery , Aged
8.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 618-625, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752251

ABSTRACT

Objective: To review the research on different surgical approaches and MRI evaluation of total hip arthroplasty (THA), to clarify the possible muscle damage caused by different approaches, and to help clinicians avoid intraoperative muscle damage and identify the causes of certain muscle-related complications after operation. Methods: The research literature on different surgical approaches and MRI evaluation of THA at home and abroad was extensively reviewed to summarize the MRI performance of the posterior approach, modified direct lateral approach, direct anterior approach, and minimally invasive anterolateral approach (also called Orthopadische Chirurgie Munchen approach). Results: The traditional posterior approach mainly damages the short external rotator muscle group and increases the incidence of postoperative dislocation; the piriformis-keeping posterior approach significantly improves the quality of the pyriformis tendon in the postoperative period, but it may lead to damage to the intrapelvic portion of the piriformis muscle. The modified direct lateral approach mainly damages the gluteus medius muscle, which increases the risk of postoperative claudication. The direct anterior approach mainly damages the vastus tensoris muscle and may result in damage to the short external rotator muscle group and the muscles around the incision. The minimally invasive anterolateral approach primarily damages the superior gluteal nerve, which subsequently leads to denervation of the broad fascial tensor fasciae latae, and this approach may also result in injury to the gluteus medius and gluteus minimus muscles. The muscle damage status significantly affects prognosis, and the minimally invasive approach is more suitable for elderly patients. Conclusion: MRI can clarify the different types of muscle damage caused by different surgical approaches. Minimally invasive approaches can reduce muscle damage and improve postoperative function compared with traditional approaches, and can benefit elderly patients more, but due to the small field, forcing to expand the surgical field will lead to unintended muscle damage and reduce postoperative function.


Subject(s)
Arthroplasty, Replacement, Hip , Magnetic Resonance Imaging , Humans , Arthroplasty, Replacement, Hip/methods , Magnetic Resonance Imaging/methods , Muscle, Skeletal/diagnostic imaging , Postoperative Complications/prevention & control , Minimally Invasive Surgical Procedures/methods
9.
Zhongguo Gu Shang ; 37(5): 464-9, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778529

ABSTRACT

OBJECTIVE: To investigate the application effect and imaging changes of metal cushion block combined with Jumbo cup in the reconstruction of acetabular bone defect after revision of artificial hip joint. METHODS: Retrospective analysis was made on the clinical data of 83 patients who underwent revision acetabular bone defect reconstruction of the artificial hip joint in our hospital from September 2019 to October 2021. They were divided into group A and group B according to different surgical methods. There were 42 patients in group A, including 26 males and 16 females, aged from 44 to 72 years old with an average of (60.57±4.62) years, who underwent revision with metal cushion block and Jumbo cup. There were 41 patients in group B, including 22 males and 19 females, aged from 42 to 71 years old with an average of (58.74±4.25) years, who underwent revision with metal cushion block and bone cement mortar cup. The operation related indexes, Harris hip function score and visual analogue scale (VAS) of pain before operation, 1 month and 12 month after operation were compared between two groups. The results of X-ray imaging examination (hip rotation center height, acetabular abduction angle, femoral eccentricity and imaging standard qualification rate) before and 12 month after operation were evaluated, and the incidence of complications was compared between two groups. RESULTS: There was no significant difference in operation time, intraoperative bleeding volume and postoperative drainage volume between two groups (P>0.05). Both groups were followed up for 12 to 36 months with an average of (25.36±3.59) months. The scores of pain, function, deformity and Harris' total score in the two groups at 1 month after operation were higher than those before operation (P<0.05), and the scores of pain, function, deformity, joint activity and Harris' total score in two groups at 1 year after operation were higher than those before operation and 1 month after operation (P<0.05), and the above scores in group A were higher than those in group B at 1 year after operation (P<0.05). The VAS of two groups decreased successively at 1 month and 1 year after operation (P<0.05), but there was no significant difference in both groups at each time point (P>0.05). The femoral eccentricity increased in both groups at 1 year after operation (P<0.05), and group A was higher than group B (P<0.05). The height of rotation center and acetabular abduction angle decreased in both groups at 1 year after operation (P<0.05), and the height of rotation center in group A was lower than that in group B (P<0.05), but there was no significant difference in acetabular abduction angle between two groups (P>0.05). The imaging qualification rate of group A was higher than that of group B (P<0.05). There was no significant difference in the incidence of adverse reactions between two groups (P>0.05). CONCLUSION: Metal cushion block combined with Jumbo cup in the treatment of acetabular bone defects can provide the hip joint function, and restore the hip joint rotation center, femoral eccentricity and acetabular abduction angle, with obvious clinical effect.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Humans , Male , Female , Middle Aged , Aged , Acetabulum/surgery , Adult , Retrospective Studies , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Reoperation , Plastic Surgery Procedures/methods , Metals
10.
Zhongguo Gu Shang ; 37(5): 482-7, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778532

ABSTRACT

OBJECTIVE: To compare the effect of patient-controlled intravenous analgesia(PCIA) and superior inguinal ligament iliac fascia block combined with PCIA after hip replacement in the elderly. METHODS: Total of 82 elderly patients were treated with hip arthroplasty from June 2019 to June 2021 and randomly divided into observation group and control group. There were 42 patients in control group, including 18 males and 24 females, aged from 60 to 78 years old with an average of (70.43±3.67) years old, 28 femoral neck fractures and 14 femoral head necrosis, who received PCIA. The study group consisted of 42 cases, including 20 males and 22 females, aged from 61 to 76 years old with an average of (69.68±3.74) years old, 25 femoral neck fractures and 17 femoral head necrosis, who received superior inguinal ligament iliac fascia block combined with PCIA. Pain visual analogue scale (VAS) and Ramesay sedation scores at 2 h, 6 h, 12 h, 24 h and 48 h after operation were evaluated. In addition, the follow-up results of the total consumption of sufentanil and the total number of PCIA compressions at 48 hours after operation, the first time of landing after surgery, the time of hospital stay, the incidence of adverse reactions, the satisfaction with analgesia of two groups were observed. RESULTS: All patients were followed up for 9 to 24 months with an average of(13.85±2.67) months. There was no significant difference in operation time and intraoperative bleeding between two groups (P>0.05). There was no difference in VAS between two groups at 2 hours after operation (P>0.05), and the VAS of the study group at 6 h, 12 h, 24 h and 48 h after operation were lower than those of the control group(P<0.05). The Ramesay sedation scores of the study group at 2 h, 6 h and 12 h after operation were higher than those of the control group(P<0.05), and there were no differences in Ramesay score between two groups at 24 h and 48 h after operation (P>0.05). The consumption of sufentanil in the study group within 48 hours after operation was lower than that in the control group (P<0.05), and PCIA compression times were lower than those in the control group(P<0.05), and the time of first landing was earlier than that in the control group(P<0.05). There was no significant difference in hospital stay, adverse reaction rate, complications between two groups (P>0.05). The satisfaction of analgesia in the study group was higher than that in the control group (P<0.05). CONCLUSION: Superior iliac fascia block of inguinal ligament combined with PCIA has significant analgesic and sedative effects after hip arthroplasty in the elderly. It can reduce the amount of sufentanil used and the total number of PCIA compressions, which is conducive to the early activity of patients out of bed, improve the satisfaction of analgesia.


Subject(s)
Analgesia, Patient-Controlled , Arthroplasty, Replacement, Hip , Nerve Block , Pain, Postoperative , Humans , Male , Arthroplasty, Replacement, Hip/methods , Female , Aged , Analgesia, Patient-Controlled/methods , Nerve Block/methods , Middle Aged , Pain, Postoperative/drug therapy , Pain, Postoperative/etiology , Pain, Postoperative/prevention & control , Fascia , Ligaments/surgery
11.
Zhongguo Gu Shang ; 37(5): 505-15, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778536

ABSTRACT

OBJECTIVE: To analyze the hip joint biomechanics of the acetabular anatomical reconstruction and nonanatomical reconstruction in total hip arthroplasty (THA) for Crowe type Ⅲ developmental dysplasia of the hip (DDH) by finite element method, which provided theoretical foundation and experimental basis for the anatomical acetabular reconstruction during THA in clinical practice. METHODS: One patient with left end-stage hip arthritis secondary to Crowe type Ⅲ DDH was selected in this study, who underwent total hip arthroplasty in the orthopedic department of the First Affiliated Hospital of Bengbu Medical College in April 2020. This patient was female, 57 years old. The preoperative and postoperative three dimentional CT scan of the patient's pelvis were performed. Fourteen acetabular cup models with different anteversion, inclination and rotation center height were established in Mimics and 3-Matic software. The boundary and load conditions were set in Abaqus software. The Von Mises and stress distribution of the hip joint were calculated and observed. RESULTS: In the Crowe type Ⅲ DDH THA, if the hip rotation center was restored anatomically and the acetabular cup's inclination was set as 40°, the cup's anteversion varied from 5° to 25°, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 20°anteversioin;if the hip rotation center was restored anatomically and the acetabular cup's anteversion was set as 15°, the cup's inclination varied from 35° to 55°, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 35° inclination;if the acetabular cup's anteversion and inclination were set as 15°and 40°respectively, the up migration of hip rotaion center varied from 0 mm to 20 mm, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 10 mm up migration. In all fourteen models, the Von Mises value of the acetabulum, acetabulum cup and polyethylene liner were lowest when the acetabular cup's anteversion and inlcination were 15°, 35° respectively, as well as the rotation center was restored anatomically. CONCLUSION: In total hip arthroplasty for Crowe type Ⅲ DDH, the anatomical restoration of hip rotation center with 15° anteversion and 35° inclination of the acetabular cup are suggested, bone graft above the acetabular cup and additional screws are recommended simultaneously to further reduce the Von Mises of hip joint.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Finite Element Analysis , Humans , Arthroplasty, Replacement, Hip/methods , Female , Middle Aged , Biomechanical Phenomena , Acetabulum/surgery , Developmental Dysplasia of the Hip/surgery , Hip Joint/surgery , Hip Joint/physiopathology , Plastic Surgery Procedures/methods
12.
Acta Ortop Mex ; 38(2): 95-100, 2024.
Article in Spanish | MEDLINE | ID: mdl-38782474

ABSTRACT

INTRODUCTION: one- or two-stage total revision is considered the gold standard for the treatment of hip arthroplasty with chronic infection. However, during the removal of a fixed prosthetic component, the host bone may be damaged, making definitive prosthetic reimplantation difficult. OBJECTIVE: we present a series of patients treated for chronic periprosthetic hip infection with preservation of one fixed component. MATERIAL AND METHODS: this study included 12 patients with hip arthroplasty and chronic periprosthetic infection scheduled for one or two-stage partial replacement with retention of a fixed component between June 2015 and January 2021. The minimum follow-up period was 2 years (mean, 4.08 years). None of the 12 patients in this series was lost to follow-up. We evaluated the evolution through clinical examination, Harris Hip Score, laboratory and radiological studies. RESULTS: at a mean follow-up of 4.08 years after prosthetic reimplantation, two of the 12 patients had recurrence of infection (16.6%), and the mean Harris hip score reached 63.6 points at the last follow-up assessment. CONCLUSIONS: fixed implant preservation may be an acceptable option for patients with chronic periprosthetic hip infection when removal of the fixed component results in significant bone loss compromising future reimplantation. However, more studies are required on this treatment method.


INTRODUCCIÓN: la revisión total en una o dos etapas se considera el estándar de oro para el tratamiento de la artroplastía de cadera con infección crónica. Sin embargo, durante la extracción de un componente protésico fijo, el hueso del huésped puede dañarse, lo que dificulta la reimplantación definitiva de la prótesis. OBJETIVO: presentamos una serie de pacientes tratados por infección crónica periprotésica de cadera con la preservación de un componente fijo. MATERIAL Y MÉTODOS: este estudio retrospectivo incluyó a 12 pacientes con artroplastía de cadera e infección periprotésica crónica programadas para revisión parcial en una o dos etapas con retención de un componente fijo entre Junio de 2015 y Enero de 2021. El período mínimo de seguimiento fue de dos años (media, 4.08 años). Ninguno de los 12 pacientes de esta serie se perdió en el seguimiento. Evaluamos la evolución a través del examen clínico, puntuación de cadera de Harris, estudios de laboratorio y radiológicos. RESULTADOS: con un seguimiento promedio de 4.08 años después de la reimplantación protésica, dos de los 12 pacientes presentaron recurrencia de la infección (16.6%) y la puntuación media de Harris en la cadera alcanzó 63.6 puntos en la última evaluación de seguimiento. CONCLUSIONES: la preservación del implante fijo puede ser una opción aceptable para pacientes estrictamente seleccionados con infección periprotésica crónica de cadera cuando la extracción del componente fijo produce una pérdida ósea significativa que compromete la reconstrucción futura. Se necesitan más estudios sobre este método de tratamiento.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis-Related Infections , Reoperation , Humans , Prosthesis-Related Infections/etiology , Male , Female , Middle Aged , Arthroplasty, Replacement, Hip/methods , Aged , Chronic Disease , Hip Prosthesis/adverse effects , Follow-Up Studies , Retrospective Studies , Adult , Recurrence
13.
Clin Interv Aging ; 19: 883-889, 2024.
Article in English | MEDLINE | ID: mdl-38784158

ABSTRACT

Objective: To compare the clinical efficacy of artificial total hip arthroplasty(THA) for femoral neck fracture between direct anterior approach(DAA) in lateral position and posterior lateral approach(PLA). Methods: Comparison of 200 cases of patients who underwent THA collected between September 2019 and August 2021 was done. Incision length, intraoperative bleeding, operative time, difference in postoperative haemoglobin from preoperative levels, length of hospital stay, postoperative time to get off the floor, visual analogue score (VAS) for pain, preoperative and postoperative Harris scores for the hip, and measurements of the acetabular abduction angle and anterior acetabular tilt angle at 6 months postoperatively were collected, and all the cases were followed up for at least 2 years. Results: Compared with the PLA group, the DAA group had a shorter incision length, less intraoperative blood loss, less postoperative haemoglobin reduction compared with the preoperative period, a shorter hospital stay and an earlier first time to get off the floor after surgery, however, the comparison of operative times was not statistically significant; Patients in the DAA group had a lower VAS in the early postoperative period compared to PLA; Patients in the DAA group had higher hip Harris scores at 6 weeks and 6 months postoperatively; There was no significant difference in acetabular abduction angle and acetabular anterior tilt angle between the two groups at 6 months postoperatively. Conclusion: Compared to PLA, DAA in THA is minimally invasive, has less pain, less bleeding, earlier time out of bed, shorter hospital stay, better early hip function, faster rehabilitation, and better joint stability.


Subject(s)
Arthroplasty, Replacement, Hip , Blood Loss, Surgical , Femoral Neck Fractures , Length of Stay , Operative Time , Humans , Arthroplasty, Replacement, Hip/methods , Femoral Neck Fractures/surgery , Male , Female , Aged , Middle Aged , Treatment Outcome , Retrospective Studies , Aged, 80 and over
14.
BMC Vet Res ; 20(1): 222, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38783269

ABSTRACT

BACKGROUND: Biomedtrix BFX® cementless total hip replacement (THR) requires the use of femoral broaches to prepare a press-fit envelope within the femur for subsequent stem insertion. Current broaches contain teeth that crush and remove cancellous bone; however, they are not particularly well-suited for broaching sclerotic (corticalized) cancellous bone. In this study, three tooth designs [Control, TG1 (additional V-grooves), TG2 (diamond tooth pattern)] were evaluated with a quasi-static testing protocol and polyurethane test blocks simulating normal and sclerotic bone. To mimic clinical broaching, a series of five sequential broach insertions were used to determine cumulative broaching energy (J) and peak loads during broach insertion. To determine the effect of broach tooth design on THR stem insertion, a BFX® stem was inserted into prepared test blocks and insertion and subsidence energy and peak loads were determined. RESULTS: Broach tooth design led to significant differences in broaching energy and peak broaching loads in test blocks of both densities. In low density test blocks, TG1 required the lowest cumulative broaching energy (10.76 ±0.29 J), followed by Control (12.18 ±1.20 J) and TG2 (16.66 ±0.78 J) broaches. In high density test blocks, TG1 required the lowest cumulative broaching energy (32.60 ±2.54 J) as compared to Control (33.25 ±2.16 J) and TG2 (59.97 ±3.07 J).  During stem insertion and subsidence testing, stem insertion energy for high density test blocks prepared with Control broaches was 14.53 ± 0.81 J, which was significantly lower than blocks prepared with TG1 (22.53 ± 1.04 J) or TG2 (19.38 ± 3.00 J) broaches. For stem subsidence testing in high density blocks, TG1 prepared blocks required the highest amount of energy to undergo subsidence (14.49 ± 0.49 J), which was significantly greater than test blocks prepared with Control (11.09 ±0.09 J) or TG2 (12.57 ± 0.81 J) broaches. CONCLUSIONS: The additional V-grooves in TG1 broaches demonstrated improved broaching performance while also generating press-fit envelopes that were more resistant to stem insertion and subsidence. TG1 broaches may prove useful in the clinical setting; however additional studies that more closely simulate clinical broach impaction are necessary prior to making widespread changes to THR broaches.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Animals , Dogs/surgery , Hip Prosthesis/veterinary , Biomechanical Phenomena , Femur/surgery
15.
PLoS One ; 19(5): e0304382, 2024.
Article in English | MEDLINE | ID: mdl-38787884

ABSTRACT

INTRODUCTION: Prevalence of total hip arthroplasty (THA) has trended upwards over past decades and is projected to increase further. Optimizing outcomes after surgery is essential to avoid surgical revision and maximize outcomes. Low back pain is reported as a problem post THA. Patient-reported outcome measures (PROMs) are commonly used to evaluate THA outcomes but have limitations (e.g., ceiling effects). It is therefore important to assess a comprehensive range of outcomes. Physical outcome measures of spinopelvic alignment and physical functioning demonstrate potential value, but no evidence synthesis has investigated their association with PROMs. The objectives of this systematic review are to evaluate the association between spinopelvic alignment and physical outcome measures of physical functioning with PROMs and characteristics of low back pain after THA. METHODS AND ANALYSIS: This protocol is aligned with the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols. Cross-sectional and longitudinal cohort studies evaluating the association between the physical outcome measures and PROMs (any outcome measures reported) following THA by any approach/implant will be included except surface replacement and revision THA. Studies investigating THA for developmental pathology and inflammatory conditions will be excluded. A systematic search in MEDLINE (Ovid), Embase (Ovid), Scopus, Web of Science, CINAHL, and the grey literature will be carried out from inception to July 31, 2023. Two independent reviewers will evaluate eligibility of retrieved articles, extract data and assess risk of bias (NIH quality assessment tool) of included studies. A third reviewer will mediate disagreements. Random-effects meta-analyses will be conducted if studies are sufficiently homogeneous in design, population, physical measures and PROMs; reporting odds ratios and 95% confidence intervals. Where meta-analyses are not possible, a narrative synthesis will be conducted. Confidence in cumulative evidence will be assessed using a modified GRADE (Grading of Recommendations Assessment, Development, and Evaluation). PROSPERO REGISTRATION NUMBER: PROSPERO Registration number CRD42023412744.


Subject(s)
Arthroplasty, Replacement, Hip , Patient Reported Outcome Measures , Systematic Reviews as Topic , Humans , Arthroplasty, Replacement, Hip/methods , Low Back Pain/surgery , Low Back Pain/physiopathology , Meta-Analysis as Topic , Spine/surgery , Spine/physiopathology
16.
J Bodyw Mov Ther ; 38: 60-66, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38763614

ABSTRACT

The use of routine ionizing imaging in identify and classify patients with dislocation or infection after surgery has some medical contraindication, in addition to risks associated with the ionizing load and elevated costs. A novel, less expensive and non-ionizing imaging technique, called infrared thermal imaging, can be proposed as a complementary method to routinely evaluate hip prosthesis patients and track their inflammation response following serious complications. Here we report a case of a total hip prosthesis which was dislocated during inpatient rehabilitation, and ultimately reduced without surgical procedure. During the process, routine clinical and radiographic diagnosis was complemented with an infrared examination. The infrared images were easy to take bedside, without direct contact with the area of surgery, and well tolerated. After the dislocation reduction, the thermal imaging procedure provided important feedbacks on the local inflammation, helping to exclude other complications such as the infections.


Subject(s)
Hip Prosthesis , Humans , Thermography/methods , Arthroplasty, Replacement, Hip/rehabilitation , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/adverse effects , Female , Prosthesis Failure , Male , Hip Dislocation , Infrared Rays , Aged , Middle Aged
17.
Acta Orthop ; 95: 250-255, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38775110

ABSTRACT

BACKGROUND AND PURPOSE: Limited research has been conducted on basicervical femoral neck fractures (bFNFs). The importance of displacement in clinical outcomes remains unclear. We aimed to characterize patient demographics, degree of displacement, treatment, treatment failures, and reoperations in a cohort of fractures from the Swedish Fracture Register (SFR). METHODS: 1,260 fractures in 1,185 individuals ≥ 60 years who had a bFNF registered in the SFR at 6 orthopedic departments from 2011 to 2020 were screened through radiographic review. The final sample included 291 patients with a confirmed bFNF. The medical records of these 291 patients were reviewed. We assessed baseline characteristics, initial fracture dislocation, treatment methods, tip-apex distance, failures, reoperations, and mortality. RESULTS: The mean age was 82 years (range 60-101, 55% women). 98 (34%) were undisplaced and 193 (66%) displaced. All patients underwent operative treatment. In the undisplaced group 95 (97%) patients received internal fixation (IF) and 3 (3%) had primary hip arthroplasty. In the displaced group 149 (77%) received IF and 41 (21%) had primary hip arthroplasty. 33 (11%) suffered treatment failure. When treating an undisplaced bFNF with IF, only 3 (3%) experienced treatment failure, in contrast to the 24 (16%) failure rate for a displaced bFNF. CONCLUSION: Undisplaced bFNFs have a low failure rate when treated with IF. For displaced bFNF treated with IF the failure rate is considerably higher. There is a need for further investigation of classification, treatment, and outcome of bFNF.


Subject(s)
Femoral Neck Fractures , Fracture Fixation, Internal , Registries , Humans , Femoral Neck Fractures/surgery , Femoral Neck Fractures/diagnostic imaging , Male , Female , Sweden/epidemiology , Middle Aged , Aged , Aged, 80 and over , Fracture Fixation, Internal/methods , Reoperation/statistics & numerical data , Arthroplasty, Replacement, Hip/methods , Treatment Failure
18.
J Orthop Traumatol ; 25(1): 25, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38727945

ABSTRACT

BACKGROUND: Acetabular cup positioning in total hip arthroplasty (THA) is closely related to outcomes. The literature has suggested cup parameters defined by the Lewinnek safe zone; however, the validity of such measures is in question. Several studies have raised concerns about the benefits of using the Lewinnek safe zone as a predictor of success. In this study we elected to use prospective surgeon targets as the basis for comparison to see how successful surgeons are positioning their cup using standard instruments and techniques. METHODS: A prospective, global, multicenter study was conducted. Cup positioning success was defined as a composite endpoint. Both cup inclination and version needed to be within 10° of the surgeon target to be considered a success. Radiographic analysis was conducted by a third-party reviewer. RESULTS: In 170 subjects, inclination, target versus actual, was 44.8° [standard deviation (SD 0.9°)] and 43.1° (SD 7.6°), respectively (p = 0.0029). Inclination was considered successful in 84.1% of cases. Mean version, target versus actual, was 19.4° (SD 3.9°) and 27.2° (SD 5.6°), respectively (p < 0.0001). Version was considered successful in 63.4% of cases, and combined position (inclination and version) was considered successful in 53.1%. CONCLUSION: This study shows that with traditional methods of placing the cup intraoperatively, surgeons are only accurate 53.1% of the time compared with a predicted preoperative plan. This study suggests that the inconsistency in cup positioning based on the surgeon's planned target is potentially another important variable to consider while using a mechanical guide or in freehand techniques for cup placement in THA. TRIAL REGISTRATION: This study is registered on ClinicalTrials.gov, NCT03189303.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Humans , Prospective Studies , Female , Male , Aged , Middle Aged , Acetabulum/surgery
19.
Bone Joint J ; 106-B(6): 548-554, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38821498

ABSTRACT

Aims: The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods: The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results: There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion: The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes.


Subject(s)
Absorptiometry, Photon , Arthroplasty, Replacement, Hip , Bone Density , Coated Materials, Biocompatible , Cortical Bone , Durapatite , Femur , Hip Prosthesis , Prosthesis Design , Humans , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Female , Male , Aged , Middle Aged , Femur/surgery , Cortical Bone/surgery
20.
Bone Joint J ; 106-B(6): 540-547, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38821495

ABSTRACT

Aims: The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon's consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years. Methods: The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken. Results: Overall implant survival was 83.50% (95% confidence interval (CI) 0.79 to 0.90) at 25 years, and the number at risk was 79. Survival in male patients at 25 years was 89.5% (95% CI 0.83 to 0.96) compared to 66.9% for female patients (95% CI 0.51 to 0.83). Ten additional failures occurred in the period of ten to 25 years. These involved an adverse reaction to metal debris in four patients, a periprosthetic femoral neck fracture affecting five patients, and aseptic loosening in one patient. The median chromium levels were 49.50 nmol/l (interquartile range (IQR) 34 to 70), and the median cobalt serum levels were 42 nmol/l (IQR 24.50 to 71.25). The median OHS at last follow-up was 35 (IQR 10 to 48). During the 25-year study period, 29 patients died. Patient survival at 25 years was 75.10% (95% CI 0.67 to 0.83). Conclusion: This study demonstrates that MoM hip resurfacing using the BHR provides a durable alternative to total hip arthroplasty (THA), particularly in younger male patients with osteoarthritis wishing to maintain a high level of function. These results compare favourably to the best results for THAs.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Prosthesis Design , Prosthesis Failure , Humans , Female , Male , Middle Aged , Arthroplasty, Replacement, Hip/methods , Adult , Aged , Adolescent , Young Adult , Follow-Up Studies , Reoperation/statistics & numerical data , Kaplan-Meier Estimate , Osteoarthritis, Hip/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...