Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.461
Filter
1.
J Am Coll Radiol ; 21(6S): S237-S248, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38823947

ABSTRACT

This document summarizes the relevant literature for the selection of preprocedural imaging in three clinical scenarios in patients needing endovascular treatment or cardioversion of atrial fibrillation. These clinical scenarios include preprocedural imaging prior to radiofrequency ablation; prior to left atrial appendage occlusion; and prior to cardioversion. The appropriateness of imaging modalities as they apply to each clinical scenario is rated as usually appropriate, may be appropriate, and usually not appropriate to assist the selection of the most appropriate imaging modality in the corresponding clinical scenarios. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Atrial Fibrillation , Evidence-Based Medicine , Societies, Medical , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Humans , United States , Preoperative Care/methods , Electric Countershock/methods , Heart Atria/diagnostic imaging , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery
2.
PLoS One ; 19(5): e0302517, 2024.
Article in English | MEDLINE | ID: mdl-38722976

ABSTRACT

OBJECTIVES: Left atrial appendage occlusion during cardiac surgery is a therapeutic option for stroke prevention in patients with atrial fibrillation. The effectiveness and safety of left atrial appendage occlusion have been evaluated in several studies, including the LAAOS-III trial. While these studies have demonstrated efficacy and safety, the long-term economic impact of this surgical technique has not yet been assessed. Here, we aimed to evaluate the cost-effectiveness and cost-utility of left atrial appendage occlusion during cardiac surgery over a long-term time horizon. METHODS: Our study was based on a model representing an hypothetical cohort with the same characteristics as LAAOS-III trial patients. We modelled the incidence of ischemic strokes and systemic embolisms in each intervention arm: "occlusion" and "no-occlusion," using a one-month cycle length with a 20-year time horizon. Regarding occlusion devices, sutures, staples, or an approved surgical occlusion device (AtriClip™-AtriCure, Ohio, USA) could be used. RESULTS: Our model generated an average cost savings of 607 euros per patient and an incremental gain of 0.062 quality-adjusted life years (QALYs), resulting an incremental cost-utility ratio (ICUR) of €-9,775/QALY. The scenario analysis in which occlusion was systematically performed using the AtriClip™ device generated an ICUR of €3,952/QALY gained. CONCLUSIONS: In the base-case analysis, the strategy proved to be more effective and less costly, confirming left atrial appendage occlusion during cardiac surgery as an economically dominant strategy. The scenario analysis also appeared cost-effective, although it did not result in cost savings. This study provides a new perspective on the assessment of the cost-effectiveness of these techniques.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Cost-Benefit Analysis , Quality-Adjusted Life Years , Humans , Atrial Appendage/surgery , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/economics , Cardiac Surgical Procedures/methods , Atrial Fibrillation/surgery , Atrial Fibrillation/economics , France , Male , Female , Stroke/prevention & control , Stroke/economics , Stroke/etiology , Aged
3.
Card Electrophysiol Clin ; 16(2): 175-180, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749638

ABSTRACT

The left atrial appendage (LAA) is now recognized as a significant contributor to arrhythmia and thromboembolism in patients with a history of atrial fibrillation. Thoracoscopic exclusion of the LAA is made possible with the AtriClip device. In this report, we describe the case of a 65-year-old man with history of multiple left atrial ablation procedures and LAA clipping. He developed a microreentrant atrial tachycardia originating from the anterior base of the LAA stump, underwent complete isolation of the LAA, and had subsequent resolution of arrhythmogenic activity from the residual LAA stump.


Subject(s)
Atrial Appendage , Humans , Atrial Appendage/surgery , Atrial Appendage/physiopathology , Aged , Male , Catheter Ablation , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Tachycardia, Supraventricular/surgery , Tachycardia, Supraventricular/physiopathology
4.
Medicine (Baltimore) ; 103(21): e38206, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38788025

ABSTRACT

OBJECTIVE: To evaluate left atrial volume and function in patients with paroxysmal atrial fibrillation (AF) combined with left atrial appendage thrombosis and patients with paroxysmal AF without left atrial appendage thrombosis by 3-dimensional speckle tracking imaging (3D-STI), and to explore the application value of this set of parameters in the evaluation of left atrial function in patients with paroxysmal AF. MATERIALS AND METHODS: A total of 40 patients with paroxysmal AF admitted from December 2018 to December 2020 were selected as the observation group. All patients with paroxysmal AF in the observation group underwent transesophageal echocardiography. According to the presence of left atrial appendage thrombosis, the patients were divided into the AF without thrombosis group (24 cases) and the AF with thrombosis group (16 cases). Thirty normal people were selected as control group who were chosen as having no heart-related disease. The left atrial volume parameters (Left atrial maximum volume LAVmax, Left atrial minimum volume LAVmin, Left atrial volume before atrial contraction LAVpre-A, Left atrial stroke volume LAEV), left atrial ejection fraction (LAEF) and left atrial strain parameters (Left atrial reservoir longitudinal strain LASr, Left atrial conduit longitudinal strain LAScd, Left atrial contraction longitudinal strain LASct, Left atrial reservoir circumferential strain LASr-c, Left atrial conduit circumferential strain LAScd-c, Left atrial contraction circumferential strain LASct-c) of the 3 groups were measured by 3D-STI. RESULTS: With the progression of paroxysmal AF, the left atrial volume increased, and the reservoir, conduit and contractile function were damaged. The left atrial volume continued to increase, and the reservoir, conduit and contractile function further decreased significantly in patients with AF combined with left atrial appendage thrombosis. LAEF was positively correlated with LASr and LASr_c. CONCLUSION: Real-time 3-dimensional spot tracking imaging (3D-STI) can evaluate the changes in left atrial volume and function in patients with paroxysmal AF, and has a certain reference value for clinical judgment of disease progression and prognosis.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Function, Left , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Male , Female , Middle Aged , Atrial Function, Left/physiology , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Echocardiography, Three-Dimensional/methods , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Echocardiography, Transesophageal/methods , Aged , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/physiopathology
5.
Trials ; 25(1): 317, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38741218

ABSTRACT

BACKGROUND: Surgical left atrial appendage (LAA) closure concomitant to open-heart surgery prevents thromboembolism in high-risk patients. Nevertheless, high-level evidence does not exist for LAA closure performed in patients with any CHA2DS2-VASc score and preoperative atrial fibrillation or flutter (AF) status-the current trial attempts to provide such evidence. METHODS: The study is designed as a randomized, open-label, blinded outcome assessor, multicenter trial of adult patients undergoing first-time elective open-heart surgery. Patients with and without AF and any CHA2DS2-VASc score will be enrolled. The primary exclusion criteria are planned LAA closure, planned AF ablation, or ongoing endocarditis. Before randomization, a three-step stratification process will sort patients by site, surgery type, and preoperative or expected oral anticoagulation treatment. Patients will undergo balanced randomization (1:1) to LAA closure on top of the planned cardiac surgery or standard care. Block sizes vary from 8 to 16. Neurologists blinded to randomization will adjudicate the primary outcome of stroke, including transient ischemic attack (TIA). The secondary outcomes include a composite outcome of stroke, including TIA, and silent cerebral infarcts, an outcome of ischemic stroke, including TIA, and a composite outcome of stroke and all-cause mortality. LAA closure is expected to provide a 60% relative risk reduction. In total, 1500 patients will be randomized and followed for 2 years. DISCUSSION: The trial is expected to help form future guidelines within surgical LAA closure. This statistical analysis plan ensures transparency of analyses and limits potential reporting biases. TRIAL REGISTRATION: Clinicaltrials.gov, NCT03724318. Registered 26 October 2018, https://clinicaltrials.gov/study/NCT03724318 . PROTOCOL VERSION: https://doi.org/10.1016/j.ahj.2023.06.003 .


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Multicenter Studies as Topic , Randomized Controlled Trials as Topic , Stroke , Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Stroke/prevention & control , Stroke/etiology , Cardiac Surgical Procedures/adverse effects , Risk Factors , Treatment Outcome , Risk Assessment , Data Interpretation, Statistical , Ischemic Attack, Transient/prevention & control , Ischemic Attack, Transient/etiology , Male , Female , Left Atrial Appendage Closure
6.
Sci Rep ; 14(1): 11937, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789491

ABSTRACT

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Retrospective Studies , Echocardiography, Transesophageal/methods , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Aged, 80 and over , Echocardiography, Three-Dimensional/methods , Middle Aged , Echocardiography/methods , Treatment Outcome , Cardiac Catheters , Left Atrial Appendage Closure
7.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691672

ABSTRACT

AIMS: Blood stasis is crucial in developing left atrial (LA) thrombi. LA appendage peak flow velocity (LAAFV) is a quantitative parameter for estimating thromboembolic risk. However, its impact on LA thrombus resolution and clinical outcomes remains unclear. METHODS AND RESULTS: The LAT study was a multicentre observational study investigating patients with atrial fibrillation (AF) and silent LA thrombi detected by transoesophageal echocardiography (TEE). Among 17 436 TEE procedures for patients with AF, 297 patients (1.7%) had silent LA thrombi. Excluding patients without follow-up examinations, we enrolled 169 whose baseline LAAFV was available. Oral anticoagulation use increased from 85.7% at baseline to 97.0% at the final follow-up (P < 0.001). During 1 year, LA thrombus resolution was confirmed in 130 (76.9%) patients within 76 (34-138) days. Conversely, 26 had residual LA thrombi, 8 had thromboembolisms, and 5 required surgical removal. These patients with failed thrombus resolution had lower baseline LAAFV than those with successful resolution (18.0 [15.8-22.0] vs. 22.2 [17.0-35.0], P = 0.003). Despite limited predictive power (area under the curve, 0.659; P = 0.001), LAAFV ≤ 20.0 cm/s (best cut-off) significantly predicted failed LA thrombus resolution, even after adjusting for potential confounders (odds ratio, 2.72; 95% confidence interval, 1.22-6.09; P = 0.015). The incidence of adverse outcomes including ischaemic stroke/systemic embolism, major bleeding, or all-cause death was significantly higher in patients with reduced LAAFV than in those with preserved LAAFV (28.4% vs. 11.6%, log-rank P = 0.005). CONCLUSION: Failed LA thrombus resolution was not rare in patients with AF and silent LA thrombi. Reduced LAAFV was associated with failed LA thrombus resolution and adverse clinical outcomes.


Subject(s)
Anticoagulants , Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Thrombosis , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/complications , Male , Female , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Aged , Thrombosis/physiopathology , Thrombosis/diagnostic imaging , Thrombosis/complications , Middle Aged , Blood Flow Velocity , Anticoagulants/therapeutic use , Risk Factors , Treatment Outcome , Asymptomatic Diseases , Time Factors , Heart Diseases/physiopathology , Heart Diseases/complications , Heart Diseases/diagnostic imaging , Thromboembolism/etiology , Thromboembolism/physiopathology , Aged, 80 and over , Atrial Function, Left
9.
Pharmacoepidemiol Drug Saf ; 33(4): e5786, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38565524

ABSTRACT

PURPOSE: Among patients with atrial fibrillation (AF), a nonpharmacologic option (e.g., percutaneous left atrial appendage occlusion [LAAO]) is needed for patients with oral anticoagulant (OAC) contraindications. Among beneficiaries in the Medicare fee-for-service coverage 20% sample databases (2015-18) who had AF and an elevated CHA2DS2-VASc score, we assessed the association between percutaneous LAAO versus OAC use and risk of stroke, hospitalized bleeding, and death. METHODS: Patients undergoing percutaneous LAAO were matched to up to five OAC users by sex, age, date of enrollment, index date, CHA2DS2-VASc score, and HAS-BLED score. Overall, 17 156 patients with AF (2905 with percutaneous LAAO) were matched (average ± SD 78 ± 6 years, 44% female). Cox proportional hazards model were used. RESULTS: Median follow-up was 10.3 months. After multivariable adjustments, no significant difference for risk of stroke or death was noted when patients with percutaneous LAAO were compared with OAC users (HRs [95% CIs]: 1.14 [0.86-1.52], 0.98 [0.86-1.10]). There was a 2.94-fold (95% CI: 2.50-3.45) increased risk for hospitalized bleeding for percutaneous LAAO compared with OAC use. Among patients 65 to <78 years old, those undergoing percutaneous LAAO had higher risk of stroke compared with OAC users. No association was present in those ≥78 years. CONCLUSION: In this analysis of real-world AF patients, percutaneous LAAO versus OAC use was associated with similar risk of death, nonsignificantly elevated risk of stroke, and an elevated risk of bleeding in the post-procedural period. Overall, these results support results of randomized trials that percutaneous LAAO may be an alternative to OAC use for patients with contraindications.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Female , Aged , United States/epidemiology , Male , Atrial Appendage/surgery , Treatment Outcome , Medicare , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Atrial Fibrillation/chemically induced , Anticoagulants/adverse effects
10.
Int Wound J ; 21(4): e14742, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38581265

ABSTRACT

Echocardiographic guidance in left atrial appendage (LAA) closure procedures is increasingly recognized for its potential to enhance patient outcomes in atrial fibrillation (AF). This retrospective study assesses its impact on hospital stay duration, readmission rates and surgical site wound complications in 200 AF patients. Divided equally into an echocardiographically guided group (Group E) and a non-guided group (Group N), the analysis focused on detailed patient data encompassing hospital stay, 30-day readmission and wound complications. Findings revealed that Group E experienced a significantly shorter average hospital stay of 3.5 days, compared with 6.5 days in Group N, along with a lower 30-day readmission rate (5% vs. 18% in Group N). Furthermore, Group E showed a considerable reduction in surgical site wound complications, such as infections and hematomas. The study concludes that echocardiographic guidance in LAA closure procedures markedly improves postoperative wound outcomes, underscoring its potential as a standard practice in cardiac surgeries for AF patients. This approach not only optimizes patient safety and postoperative recovery but also enhances healthcare resource utilization.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Retrospective Studies , Left Atrial Appendage Closure , Treatment Outcome , Echocardiography , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Postoperative Complications/prevention & control , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery
11.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Article in English | MEDLINE | ID: mdl-38563835

ABSTRACT

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Organothiophosphorus Compounds , Pulmonary Veins , Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Bayes Theorem , Prospective Studies , Pulmonary Veins/surgery , Catheter Ablation , Catheterization
12.
BMC Cardiovasc Disord ; 24(1): 207, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38614995

ABSTRACT

OBJECTIVE: This study aimed to investigate the serum levels of Peptidase M20 domain containing 1 (PM20D1) in idiopathic pulmonary arterial hypertension (IPAH) patients and examine its association with lipid metabolism, echocardiography, and hemodynamic parameters. METHODS: This prospective observational research enrolled 103 IPAH patients from January 2018 to January 2022. Enzyme-linked immunosorbent assay (ELISA) was used to measure the serum PM20D1 levels in all patients before treatment within 24 h of admission. Demographic data, echocardiography, hemodynamic parameters and serum biomarkers were also collected. RESULTS: The IPAH patients in the deceased group had significantly elevated age, right atrial (RA), mean pulmonary arterial pressure (mPAP), mean right atrial pressure (mRAP), pulmonary capillary wedge pressure (PCWP), pulmonary vascular resistance (PVR) and significantly decreased 6 min walking distance (6MWD) and tricuspid annulus peak systolic velocity (TASPV). IPAH patients showed significant decreases in serum PM20D1, low-density lipoprotein cholesterol (LDL-C), and albumin (ALB). Additionally, PM20D1 was negatively correlated with RA, NT-proBNP and positively correlated with PVR, ALB, 6MWD, and TAPSV. Moreover, PM20D1 has the potential as a biomarker for predicting IPAH patients' prognosis. Finally, logistic regression analysis indicated that PM20D1, ALB, NT-proBNP, PVR, TASPV, RA and 6MWD were identified as risk factors for mortality in IPAH patients. CONCLUSION: Our findings indicated that the serum levels of PM20D1 were significantly decreased in IPAH patients with poor prognosis. Moreover, PM20D1 was identified as a risk factor associated with mortality in IPAH patients.


Subject(s)
Atrial Appendage , Clinical Relevance , Humans , Familial Primary Pulmonary Hypertension/diagnosis , Heart Atria , Albumins
13.
Ann Noninvasive Electrocardiol ; 29(3): e13119, 2024 May.
Article in English | MEDLINE | ID: mdl-38682420

ABSTRACT

BACKGROUND: To avoid causing a thromboembolic event in patients undergoing catheter ablation for atrial fibrillation (AF), patients are treated with oral anticoagulants (OAC) prior to the procedure. Despite being on anticoagulants, some patients develop a left atrial appendage thrombus (LAAT). To exclude the presence of LAAT, transesophageal ultrasound (TEE) is performed in all patients prior to the procedure. We hypothesized continuous treatment with anticoagulants would result in a low prevalence of LAAT, in patients with low CHA2DS2-VASc score. METHOD: Medical records of consecutive patients planned to undergo AF ablation at Lund University Hospital during the years 2018-2020 were reviewed retrospectively. Examination protocols from transesophageal and transthoracic echocardiography were examined for LAAT and spontaneous echo contrast (SEC). Patients with LAAT and SEC were compared to patients without using Mann-Whitney U-test and Pearson Chi-squared analysis to test for correlation. RESULTS: Of 553 patients, three patients (0.54%) had LAAT, and 18 (3.25%) had spontaneous contrast (SEC). Patients with LAAT or SEC had a higher CHA2DS2-VASc score, more often presented in AF at TEE and less often had a normal sized left atrium. CONCLUSION: There is a low prevalence of LAAT and SEC in patients with AF scheduled for pulmonary vein isolation. Patients with SEC or LAAT tend to have paroxysmal AF less often and more often presented in AF at admission. No patients with CHA2DS2-VASc 0, paroxysmal AF, normal sized left atrium and sinus rhythm at TEE were found to have LAAT or SEC.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Echocardiography, Transesophageal , Pulmonary Veins , Thrombosis , Humans , Echocardiography, Transesophageal/methods , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Male , Female , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Catheter Ablation/methods , Retrospective Studies , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Prevalence , Middle Aged , Aged , Anticoagulants/therapeutic use , Heart Diseases/diagnostic imaging , Heart Diseases/epidemiology
14.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38637325

ABSTRACT

AIMS: Left atrial appendage electrical isolation (LAAEI) has demonstrated a significant enhancement in the success rate of atrial fibrillation (AF) ablation. Nevertheless, concerns persist about the safety of LAAEI, particularly regarding alterations in left atrial appendage (LAA) flow velocity and the potential risks of thrombus. This study aimed to assess the efficacy and safety of LAAEI, investigating changes in LAA flow velocity in canines. METHODS AND RESULTS: The study comprised a total of 10 canines. The LAAEI procedure used by a 23 mm cryoballoon of the second generation was conducted at least 180 s. Intracardiac ultrasonography (ICE) was employed to quantify the velocity flow of the LAA both prior to and following LAAEI. Following a 3-month period, subsequent evaluations were performed to assess the LAA velocity flow and the potential reconnection. Histopathological examination was conducted. Left atrial appendage electrical isolation was effectively accomplished in all canines, resulting in a 100% acute success rate (10/10). The flow velocity in the LAA showed a notable reduction during LAAEI as compared with the values before the ablation procedure (53.12 ± 5.89 vs. 42.01 ± 9.22 cm/s, P = 0.007). After the follow-up, reconnection was observed in four canines, leading to a success rate of LAAEI of 60% (6/10). The flow velocity in the LAA was consistently lower (53.12 ± 5.89 vs. 44.33 ± 10.49 cm/s, P = 0.006), and no blood clot development was observed. The histopathological study indicated that there was consistent and complete injury to the LAA, affecting all layers of its wall. The injured tissue was subsequently replaced by fibrous tissue. CONCLUSION: The feasibility of using cryoballoon ablation for LAAEI was confirmed in canines, leading to a significant reduction of LAA flow velocity after ablation. Some restoration of LAA flow velocity after ablation may be linked to the passive movement of the LAA and potential reconnecting. However, this conclusion is limited to animal study; more clinical data are needed to further illustrate the safety and accessibility of LAAEI in humans.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cryosurgery , Dogs , Animals , Atrial Appendage/surgery , Cryosurgery/methods , Cryosurgery/adverse effects , Cryosurgery/instrumentation , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Equipment Design , Blood Flow Velocity , Treatment Outcome , Male
15.
Kardiologiia ; 64(3): 11-17, 2024 Mar 31.
Article in Russian, English | MEDLINE | ID: mdl-38597757

ABSTRACT

AIM: To study the relationship between changes in left atrial volume (LAV) during exercise and the result of a diastolic stress test (DST) in patients with arterial hypertension (AH). MATERIAL AND METHODS: The study included 219 patients with AH without ischemic heart disease and atrial fibrillation. During the DST performed before and after exercise, the ratio of transmitral flow velocity to mitral annular velocity (E/e'), the left atrial global longitudinal strain in the reservoir phase (reservoir strain), and LAV were determined. The criterion for a positive DST was an increase in E/e' ≥15. RESULTS: A positive result of DST was observed in 90 (41.1%) patients. Patients with positive DST were older (65.0 and 59.0 years); among them, there were fewer men (24.4 and 41.1%), but more patients with obesity (66.7 and 40.3%) and diabetes mellitus (36.7 and 8.5%). At rest, patients with positive DST had higher E/e' ratio (11.5 and 8.8), pulmonary artery systolic pressure (29.0 and 27.0 mm Hg), and LAV (60.0 and 52.0 ml), but a lower left atrial reservoir strain (20.0 and 24.0%). During exercise in patients with positive and negative DST, E/e' increased by 5.46 and 0.47 units, respectively. Changes in the LAV and reservoir strain during exercise in these groups were directed differently. In patients with positive DST, the left atrial reservoir strain decreased by 1.0 percentage points (pp) whereas in patients with negative DST, it increased by 8.0 pp. During exercise, the LAV increased by 10.0 ml in patients with a positive DST, whereas in the alternative group, the LAV decreased by 8.5 ml. The AUC for changes in LAV as an indicator of a positive DST was 0.987 while the AUC for the resting left atrial reservoir strain was 0.938. An increase in LAV >1 ml, as an indicator of a positive DST has a sensitivity of 96.9% and a specificity of 95.1%. CONCLUSION: In AH patients, changes in left ventricular filling pressure are associated with a unidirectional change in LAV. An increase in LAV during exercise by more than 1 ml can serve as a criterion for a positive DST result. This assessment was consistent with the assessment of the DST result by the E/e' criterion >15 in 94.5% of cases.


Subject(s)
Atrial Appendage , Hypertension , Male , Humans , Exercise Test , Heart Atria/diagnostic imaging , Exercise , Hypertension/complications , Hypertension/diagnosis
16.
Cell Mol Biol (Noisy-le-grand) ; 70(4): 225-230, 2024 Apr 28.
Article in English | MEDLINE | ID: mdl-38678600

ABSTRACT

This study compared the therapeutic effect and safety between warfarin anticoagulation and percutaneous left atrial appendage transcatheter occlusion (PLAATO) in non-valvular atrial fibrillation (NVAF). A total of 110 patients were selected and assigned to Control group (n=55) and Observation group (n=55). The control patients were used warfarin, while the observation patients were performed PLAATO. The coagulation function, stroke and bleeding scores were compared between the two groups at different times. Left ventricular function before therapy and 1 year after therapy and adverse events during follow-up were compared between the two groups. After one month of treatment, CHA2DS2-VASC, HAS-BLED score, serum ET-1 and hs-CRP levels were lower in the PLAATO patients than in warfarin patients, but serum PDGFs levels were higher than patients in the warfarin patients (P < 0.05). One month after treatment, the activated partial thromboplastin time (APTT), prothrombin time (PT), and thrombin time (TT) of the PLAATO patients was longer than that of the warfarin patients (P < 0.05), but the levels of fibrinogen (FIB) in the PLAATO patients were lower than that of the warfarin patients (P < 0.05). In addition, one year after therapy, the left atrial end-diastolic volume (LAEDV), left atrial end-systolic volume (LAESV) and left atrial inner diameter of the two groups were significantly reduced (P < 0.05). Left atrial appendage (LAA) occlusion can effectively improve the cardiac function and coagulation function of NVAF patients, with lower incidence of bleeding events, stroke events and higher safety.


Subject(s)
Anticoagulants , Atrial Appendage , Atrial Fibrillation , Warfarin , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/therapy , Warfarin/therapeutic use , Warfarin/adverse effects , Male , Atrial Appendage/surgery , Female , Anticoagulants/therapeutic use , Anticoagulants/adverse effects , Aged , C-Reactive Protein/metabolism , Middle Aged , Treatment Outcome , Stroke/etiology , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects
17.
Radiol Cardiothorac Imaging ; 6(2): e240020, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38602468

ABSTRACT

Radiology: Cardiothoracic Imaging publishes novel research and technical developments in cardiac, thoracic, and vascular imaging. The journal published many innovative studies during 2023 and achieved an impact factor for the first time since its inaugural issue in 2019, with an impact factor of 7.0. The current review article, led by the Radiology: Cardiothoracic Imaging trainee editorial board, highlights the most impactful articles published in the journal between November 2022 and October 2023. The review encompasses various aspects of coronary CT, photon-counting detector CT, PET/MRI, cardiac MRI, congenital heart disease, vascular imaging, thoracic imaging, artificial intelligence, and health services research. Key highlights include the potential for photon-counting detector CT to reduce contrast media volumes, utility of combined PET/MRI in the evaluation of cardiac sarcoidosis, the prognostic value of left atrial late gadolinium enhancement at MRI in predicting incident atrial fibrillation, the utility of an artificial intelligence tool to optimize detection of incidental pulmonary embolism, and standardization of medical terminology for cardiac CT. Ongoing research and future directions include evaluation of novel PET tracers for assessment of myocardial fibrosis, deployment of AI tools in clinical cardiovascular imaging workflows, and growing awareness of the need to improve environmental sustainability in imaging. Keywords: Coronary CT, Photon-counting Detector CT, PET/MRI, Cardiac MRI, Congenital Heart Disease, Vascular Imaging, Thoracic Imaging, Artificial Intelligence, Health Services Research © RSNA, 2024.


Subject(s)
Atrial Appendage , Heart Defects, Congenital , Radiology , Humans , Contrast Media , Artificial Intelligence , Gadolinium , Tomography, X-Ray Computed
18.
Medicine (Baltimore) ; 103(14): e37742, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579037

ABSTRACT

BACKGROUND: Atrial fibrillation is the most common cardiac arrhythmia, affecting 32 million individuals worldwide. Although atrial fibrillation has been studied for decades, a comprehensive analysis using bibliometrics has not been performed for atrial fibrillation-left atrial appendage occlusion (LAAO). Therefore, we analyzed the scientific outputs of global LAAO research and explored the current research status and hotpots from 1994 to 2022. METHODS: We searched the Web of Science core collection for publications related to LAAO that were published between 1994 and 2022. We then performed bibliometric analysis and visualization using Microsoft Excel 2021, Bibliometric (https://bibliometric.com), VOSviewer (version 1.6.19), CiteSpace (version 6.2. R2), and the Bibliometrix 4.0.0 Package (https://www.bibliometrix.org) based on the R language were used to perform the bibliometric analysis, trend and emerging foci of LAAO in the past 29 years, including author, country, institution, journal distribution, article citations, and keywords. In total, we identified 1285 eligible publications in the field of LAAO, with an increasing trend in the annual number of publications. RESULTS: The United States is the country with the most published articles in this field, while the United Kingdom is the country with the most cited literature. Mayo Clinic, from the United States, has the most publications in this area and Horst Sievert from Germany had the highest number of individual publications. The analysis of keywords showed that fibrillation, stroke, safety, oral anticoagulants, and watchman were the main hotpots and frontier directions of LAAO. Surgical treatment of nonvalvular atrial fibrillation, upgrading of related surgical instruments, and anticoagulation regimen after surgical treatment are the major research frontiers. CONCLUSION: We show that the research of percutaneous LAAO has been increasing rapidly over the last decade. Our aim was to overview past studies in the field of LAAO, to grasp the frame of LAAO research, and identify new perspectives for future research.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Ambulatory Care Facilities , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Bibliometrics , Cardiac Conduction System Disease
19.
Am J Cardiol ; 220: 39-46, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38583697

ABSTRACT

This study evaluated the nationwide associations between concomitant left atrial appendage clip (LAAC) placement during cardiac surgery and postoperative outcomes. We identified 1,260,999 patients who underwent coronary artery bypass grafting, valve, and aortic surgeries in the 2016 to 2020 Nationwide Readmissions Database and stratified by concomitant LAAC versus no LAAC placement. Patients who underwent surgical ablation were excluded. Mortality and complications were compared during index admissions and for patients readmitted within 30 and 90 days of the index discharge date for unmatched and propensity score-matched groups. Overall, 6.7% (84,293) of patients underwent cardiac surgery and concomitant LAAC placement without surgical ablation. After propensity score matching, the index admission mortality and overall complications were not different in patients with LAAC versus patients without LAAC. LAAC placement was associated with increased any-cause 30-day readmissions (15% vs 13%, p <0.01). In patients with LAAC, within 30 days, there were no differences in mortality (3.9% vs 3.8%, p = 0.60) or overall complications (64% vs 63%, p = 0.20), whereas stroke was lower (5.3% vs 6.5%, p <0.01) and heart failure was higher (35% vs 30%, p <0.01). For patients readmitted within 90 days, similar findings were observed for any-cause readmissions, mortality, overall complications, stroke, and heart failure. In conclusion, concomitant LAAC placement during cardiac surgery was associated with lower early postdischarge incidence of stroke and a favorable overall risk-benefit profile. Given these short-term findings in a real-world population of all patients who underwent cardiac surgery, longer-term studies with more granular data are needed to evaluate the potential benefit of this practice.


Subject(s)
Atrial Appendage , Cardiac Surgical Procedures , Patient Readmission , Postoperative Complications , Humans , Atrial Appendage/surgery , Male , Female , Aged , Cardiac Surgical Procedures/methods , Postoperative Complications/epidemiology , Middle Aged , Patient Readmission/statistics & numerical data , United States/epidemiology , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Propensity Score , Stroke/epidemiology , Stroke/etiology , Surgical Instruments , Coronary Artery Bypass/methods , Retrospective Studies
20.
Catheter Cardiovasc Interv ; 103(7): 1152-1155, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38606476

ABSTRACT

The use of left atrial appendage occlusion (LAAO) devices have gained prominence as an alternative to long-term anticoagulation therapy in patients with atrial fibrillation at risk of stroke and high risk of bleeding. While these devices have shown efficacy in reducing stroke risk, there have been reported cases of embolization of the Watchman device. There are very few cases of successful percutaneous retrieval of embolized Watchman devices from the left ventricle (LV), as many of these cases require open heart surgery for safe removal. We are presenting a case of an 80-year-old male whose Watchman device embolized to the LV and was entrapped on the LV papillary muscle that was then successfully retrieved via percutaneous methods, which shows the percutaneous options remain a viable strategy to retrieve LAAO devices from the LV.


Subject(s)
Atrial Fibrillation , Cardiac Catheterization , Device Removal , Foreign-Body Migration , Papillary Muscles , Humans , Male , Aged, 80 and over , Treatment Outcome , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Foreign-Body Migration/therapy , Foreign-Body Migration/etiology , Foreign-Body Migration/diagnostic imaging , Papillary Muscles/diagnostic imaging , Heart Ventricles/diagnostic imaging , Embolism/etiology , Embolism/diagnostic imaging , Embolism/therapy , Embolism/diagnosis , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Echocardiography, Transesophageal
SELECTION OF CITATIONS
SEARCH DETAIL
...