Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 15.603
Filter
1.
Echocardiography ; 41(5): e15830, 2024 May.
Article in English | MEDLINE | ID: mdl-38727181

ABSTRACT

Atrial fibrillation (AF) could impact on left ventricular function leading to a sublinical myocardial dysfunction, as identified by myocardial work parameters in a population-based cohort of AF patients compared with healthy individuals; factors associated with these parameters are also shown. SBP: systolic blood pressure; LAVI: left atrial volume index.


Subject(s)
Atrial Fibrillation , Ventricular Dysfunction, Left , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/complications , Male , Female , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/complications , Middle Aged , Echocardiography/methods , Aged
2.
Scand Cardiovasc J ; 58(1): 2347297, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38695238

ABSTRACT

Objectives. Atrial fibrillation is a common arrhythmia in patients with ischemic heart disease. This study aimed to determine the cumulative incidence of new-onset atrial fibrillation after percutaneous coronary intervention or coronary artery bypass grafting surgery during 30 days of follow-up. Design. This was a prospective multi-center cohort study on atrial fibrillation incidence following percutaneous coronary intervention or coronary artery bypass grafting for stable angina or non-ST-elevation acute coronary syndrome. Heart rhythm was monitored for 30 days postoperatively by in-hospital telemetry and handheld thumb ECG recordings after discharge were performed. The primary endpoint was the cumulative incidence of atrial fibrillation 30 days after the index procedure. Results. In-hospital atrial fibrillation occurred in 60/123 (49%) coronary artery bypass graft and 0/123 percutaneous coronary intervention patients (p < .001). The cumulative incidence of atrial fibrillation after 30 days was 56% (69/123) of patients undergoing coronary artery bypass grafting and 2% (3/123) of patients undergoing percutaneous coronary intervention (p < .001). CABG was a strong predictor for atrial fibrillation compared to PCI (OR 80.2, 95% CI 18.1-354.9, p < .001). Thromboembolic stroke occurred in-hospital in one coronary artery bypass graft patient unrelated to atrial fibrillation, and at 30 days in two additional patients, one in each group. There was no mortality. Conclusion. New-onset atrial fibrillation during 30 days of follow-up was rare after percutaneous coronary intervention but common after coronary artery bypass grafting. A prolonged uninterrupted heart rhythm monitoring strategy identified additional patients in both groups with new-onset atrial fibrillation after discharge.


Subject(s)
Atrial Fibrillation , Coronary Artery Bypass , Percutaneous Coronary Intervention , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/etiology , Prospective Studies , Percutaneous Coronary Intervention/adverse effects , Male , Incidence , Female , Coronary Artery Bypass/adverse effects , Aged , Middle Aged , Risk Factors , Time Factors , Treatment Outcome , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnosis , Heart Rate , Angina, Stable/diagnosis , Angina, Stable/physiopathology , Angina, Stable/epidemiology , Angina, Stable/surgery , Angina, Stable/therapy , Risk Assessment , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/surgery , Acute Coronary Syndrome/epidemiology , Telemetry
3.
Card Electrophysiol Clin ; 16(2): 169-174, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749637

ABSTRACT

A 34-year-old woman presented with palpitations and paroxysmal atrial fibrillation (AF). Workup revealed anterior mitral valve prolapse with severe mitral regurgitation. She was referred for surgical repair and underwent a mitral valve replacement, tricuspid valve repair, and bi-atrial cryoMAZE procedure with left atrial appendage ligation. Her postoperative course was complicated by inferior wall myocardial infarction. She subsequently presented with palpitations and underwent electrophysiology study and ablation. This case illustrates pitfalls associated with the surgical MAZE procedure and highlights the challenges in postoperative atrial arrhythmias diagnosis and management.


Subject(s)
Atrial Fibrillation , Maze Procedure , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Adult , Diagnosis, Differential , Postoperative Complications/diagnosis , Catheter Ablation/adverse effects , Electrocardiography , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/surgery
4.
J Am Coll Cardiol ; 83(20): 2015-2027, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749620

ABSTRACT

The identification of the pulmonary veins as a trigger source for atrial fibrillation (AF) has established pulmonary vein isolation (PVI) as a key target for AF ablation. However, PVI alone does not prevent recurrent AF in many patients, and numerous additional ablation strategies have failed to improve on PVI outcomes. This therapeutic limitation may be due, in part, to a failure to identify and intervene specifically on the pro-fibrillatory substrate within the atria and pulmonary veins. In this review paper, we highlight several emerging approaches with clinical potential that target atrial cardiomyopathy-the underlying anatomic, electrical, and/or autonomic disease affecting the atrium-in various stages of practice and investigation. In particular, we consider the evolving roles of risk factor modification, targeting of epicardial adipose tissue, tissue fibrosis, oxidative stress, and the inflammasome, along with aggressive early anti-AF therapy in AF management. Attention to combatting substrate development promises to improve outcomes in AF.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Humans , Catheter Ablation/methods , Pulmonary Veins/surgery
5.
Card Electrophysiol Clin ; 16(2): 181-186, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749639

ABSTRACT

A 70-year-old man with recurrent atrial fibrillation (AF) underwent transcatheter radiofrequency ablation after an earlier unsuccessful attempt. Although typical AF triggers were ablated, the patient's condition persisted, leading to the identification of the interatrial septum (IAS) as the probable source of the tachycardia trigger. Given the depth and thickness of the IAS, traditional radiofrequency ablation proved ineffective. However, using the alternative method of bipolar radiofrequency catheter ablation (B-RFCA), the atrial tachycardia was successfully terminated. B-RFCA demonstrates potential for effectively terminating tachycardias originating from deep intramural locations, suggesting its potential as a pivotal technique for complex cases with septal atrial tachycardia.


Subject(s)
Catheter Ablation , Humans , Male , Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Septum/surgery , Atrial Septum/diagnostic imaging
6.
Card Electrophysiol Clin ; 16(2): 175-180, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749638

ABSTRACT

The left atrial appendage (LAA) is now recognized as a significant contributor to arrhythmia and thromboembolism in patients with a history of atrial fibrillation. Thoracoscopic exclusion of the LAA is made possible with the AtriClip device. In this report, we describe the case of a 65-year-old man with history of multiple left atrial ablation procedures and LAA clipping. He developed a microreentrant atrial tachycardia originating from the anterior base of the LAA stump, underwent complete isolation of the LAA, and had subsequent resolution of arrhythmogenic activity from the residual LAA stump.


Subject(s)
Atrial Appendage , Humans , Atrial Appendage/surgery , Atrial Appendage/physiopathology , Aged , Male , Catheter Ablation , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Tachycardia, Supraventricular/surgery , Tachycardia, Supraventricular/physiopathology
7.
Science ; 384(6697): 722-723, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38753800

ABSTRACT

Studying cardiac effects of extreme exercise could yield clues to atrial fibrillation.


Subject(s)
Athletes , Atrial Fibrillation , Exercise , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/etiology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology
8.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38701222

ABSTRACT

AIMS: Pulsed field ablation (PFA) for the treatment of atrial fibrillation (AF) potentially offers improved safety and procedural efficiencies compared with thermal ablation. Opportunities remain to improve effective circumferential lesion delivery, safety, and workflow of first-generation PFA systems. In this study, we aim to evaluate the initial clinical experience with a balloon-in-basket, 3D integrated PFA system with a purpose-built form factor for pulmonary vein (PV) isolation. METHODS AND RESULTS: The VOLT CE Mark Study is a pre-market, prospective, multi-centre, single-arm study to evaluate the safety and effectiveness of the Volt™ PFA system for the treatment of paroxysmal (PAF) or persistent AF (PersAF). Feasibility sub-study subjects underwent phrenic nerve evaluation, endoscopy, chest computed tomography, and cerebral magnetic resonance imaging. Study endpoints were the rate of primary serious adverse event within 7 days and acute procedural effectiveness. A total of 32 subjects (age 61.6 ± 9.6 years, 65.6% male, 84.4% PAF) were enrolled and treated in the feasibility sub-study and completed a 30-day follow-up. Acute effectiveness was achieved in 99.2% (127/128) of treated PVs (96.9% of subjects, 31/32) with 23.8 ± 4.2 PFA applications/subject. Procedure, fluoroscopy, LA dwell, and transpired ablation times were 124.6 ± 28.1, 19.8 ± 8.9, 53.0 ± 21.0, and 48.0 ± 19.9 min, respectively. Systematic assessments of initial safety revealed no phrenic nerve injury, pulmonary vein stenosis, or oesophageal lesions causally related to the PFA system and three subjects with silent cerebral lesions (9.4%). There were no primary serious adverse events. CONCLUSION: The initial clinical use of the Volt PFA System demonstrates acute safety and effectiveness in the treatment of symptomatic, drug refractory AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Feasibility Studies , Pulmonary Veins , Humans , Male , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Middle Aged , Pulmonary Veins/surgery , Treatment Outcome , Prospective Studies , Catheter Ablation/methods , Catheter Ablation/instrumentation , Aged , Equipment Design , Phrenic Nerve/injuries , Time Factors
9.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696675

ABSTRACT

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
10.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726722

ABSTRACT

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Electrocardiography, Ambulatory , Transcatheter Aortic Valve Replacement , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aortic Valve Stenosis/surgery , Aged, 80 and over , Electrocardiography, Ambulatory/methods , Risk Factors , Treatment Outcome
11.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38743765

ABSTRACT

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Subject(s)
Consensus , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Predictive Value of Tests , Europe , Treatment Outcome
12.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691672

ABSTRACT

AIMS: Blood stasis is crucial in developing left atrial (LA) thrombi. LA appendage peak flow velocity (LAAFV) is a quantitative parameter for estimating thromboembolic risk. However, its impact on LA thrombus resolution and clinical outcomes remains unclear. METHODS AND RESULTS: The LAT study was a multicentre observational study investigating patients with atrial fibrillation (AF) and silent LA thrombi detected by transoesophageal echocardiography (TEE). Among 17 436 TEE procedures for patients with AF, 297 patients (1.7%) had silent LA thrombi. Excluding patients without follow-up examinations, we enrolled 169 whose baseline LAAFV was available. Oral anticoagulation use increased from 85.7% at baseline to 97.0% at the final follow-up (P < 0.001). During 1 year, LA thrombus resolution was confirmed in 130 (76.9%) patients within 76 (34-138) days. Conversely, 26 had residual LA thrombi, 8 had thromboembolisms, and 5 required surgical removal. These patients with failed thrombus resolution had lower baseline LAAFV than those with successful resolution (18.0 [15.8-22.0] vs. 22.2 [17.0-35.0], P = 0.003). Despite limited predictive power (area under the curve, 0.659; P = 0.001), LAAFV ≤ 20.0 cm/s (best cut-off) significantly predicted failed LA thrombus resolution, even after adjusting for potential confounders (odds ratio, 2.72; 95% confidence interval, 1.22-6.09; P = 0.015). The incidence of adverse outcomes including ischaemic stroke/systemic embolism, major bleeding, or all-cause death was significantly higher in patients with reduced LAAFV than in those with preserved LAAFV (28.4% vs. 11.6%, log-rank P = 0.005). CONCLUSION: Failed LA thrombus resolution was not rare in patients with AF and silent LA thrombi. Reduced LAAFV was associated with failed LA thrombus resolution and adverse clinical outcomes.


Subject(s)
Anticoagulants , Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Thrombosis , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/complications , Male , Female , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Aged , Thrombosis/physiopathology , Thrombosis/diagnostic imaging , Thrombosis/complications , Middle Aged , Blood Flow Velocity , Anticoagulants/therapeutic use , Risk Factors , Treatment Outcome , Asymptomatic Diseases , Time Factors , Heart Diseases/physiopathology , Heart Diseases/complications , Heart Diseases/diagnostic imaging , Thromboembolism/etiology , Thromboembolism/physiopathology , Aged, 80 and over , Atrial Function, Left
13.
Cell Rep Med ; 5(5): 101559, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38744275

ABSTRACT

Dysfunction of the sympathetic nervous system and increased epicardial adipose tissue (EAT) have been independently associated with the occurrence of cardiac arrhythmia. However, their exact roles in triggering arrhythmia remain elusive. Here, using an in vitro coculture system with sympathetic neurons, cardiomyocytes, and adipocytes, we show that adipocyte-derived leptin activates sympathetic neurons and increases the release of neuropeptide Y (NPY), which in turn triggers arrhythmia in cardiomyocytes by interacting with the Y1 receptor (Y1R) and subsequently enhancing the activity of the Na+/Ca2+ exchanger (NCX) and calcium/calmodulin-dependent protein kinase II (CaMKII). The arrhythmic phenotype can be partially blocked by a leptin neutralizing antibody or an inhibitor of Y1R, NCX, or CaMKII. Moreover, increased EAT thickness and leptin/NPY blood levels are detected in atrial fibrillation patients compared with the control group. Our study provides robust evidence that the adipose-neural axis contributes to arrhythmogenesis and represents a potential target for treating arrhythmia.


Subject(s)
Adipocytes , Adipose Tissue , Arrhythmias, Cardiac , Leptin , Myocytes, Cardiac , Neuropeptide Y , Pericardium , Humans , Animals , Pericardium/metabolism , Pericardium/pathology , Adipose Tissue/metabolism , Adipose Tissue/pathology , Arrhythmias, Cardiac/metabolism , Arrhythmias, Cardiac/pathology , Myocytes, Cardiac/metabolism , Myocytes, Cardiac/pathology , Neuropeptide Y/metabolism , Leptin/metabolism , Adipocytes/metabolism , Male , Calcium-Calmodulin-Dependent Protein Kinase Type 2/metabolism , Neurons/metabolism , Neurons/pathology , Sodium-Calcium Exchanger/metabolism , Female , Receptors, Neuropeptide Y/metabolism , Middle Aged , Atrial Fibrillation/metabolism , Atrial Fibrillation/physiopathology , Atrial Fibrillation/pathology , Sympathetic Nervous System/metabolism , Mice , Epicardial Adipose Tissue
14.
Int J Artif Organs ; 47(5): 329-337, 2024 May.
Article in English | MEDLINE | ID: mdl-38742880

ABSTRACT

BACKGROUND: This study investigates the hypothesis that presence of atrial fibrillation (AF) in LVAD patients increases thrombogenicity in the left ventricle (LV) and exacerbates stroke risk. METHODS: Using an anatomical LV model implanted with an LVAD inflow cannula, we analyze thrombogenic risk and blood flow patterns in either AF or sinus rhythm (SR) using unsteady computational fluid dynamics (CFD). To analyze platelet activation and thrombogenesis in the LV, hundreds of thousands of platelets are individually tracked to quantify platelet residence time (RT) and shear stress accumulation history (SH). RESULTS: The irregular and chaotic mitral inflow associated with AF results in markedly different intraventricular flow patterns, with profoundly negative impact on blood flow-induced stimuli experienced by platelets as they traverse the LV. Twice as many platelets accumulated very high SH in the LVAD + AF case, resulting in a 36% increase in thrombogenic potential score, relative to the LVAD + SR case. CONCLUSIONS: This supports the hypothesis that AF results in unfavorable blood flow patterns in the LV adding to an increased stroke risk for LVAD + AF patients. Quantification of thrombogenic risk associated with AF for LVAD patients may help guide clinical decision-making on interventions to mitigate the increased risk of thromboembolic events.


Subject(s)
Atrial Fibrillation , Heart-Assist Devices , Atrial Fibrillation/physiopathology , Atrial Fibrillation/etiology , Heart-Assist Devices/adverse effects , Humans , Thrombosis/etiology , Thrombosis/physiopathology , Platelet Activation , Models, Cardiovascular , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Stroke/etiology , Blood Platelets/metabolism , Ventricular Function, Left , Models, Anatomic , Hydrodynamics , Hemodynamics
15.
Scand Cardiovasc J ; 58(1): 2353069, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38794854

ABSTRACT

OBJECTIVES: Atrial fibrillation (AF) is a common early arrhythmia after heart valve surgery that limits physical activity. We aimed to evaluate the criterion validity of the Apple Watch Series 5 single-lead electrocardiogram (ECG) for detecting AF in patients after heart valve surgery. DESIGN: We enrolled 105 patients from the University Hospital of North Norway, of whom 93 completed the study. All patients underwent single-lead ECG using the smartwatch three times or more daily on the second to third or third to fourth postoperative day. These results were compared with continuous 2-4 days ECG telemetry monitoring and a 12-lead ECG on the third postoperative day. RESULTS: On comparing the Apple Watch ECGs with the ECG monitoring, the sensitivity and specificity to detect AF were 91% (75, 100) and 96% (91, 99), respectively. The accuracy was 95% (91, 99). On comparing Apple Watch ECG with a 12-lead ECG, the sensitivity was 71% (62, 100) and the specificity was 92% (92, 100). CONCLUSION: The Apple smartwatch single-lead ECG has high sensitivity and specificity, and might be a useful tool for detecting AF in patients after heart valve surgery.


Subject(s)
Atrial Fibrillation , Heart Rate , Predictive Value of Tests , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Male , Prospective Studies , Female , Aged , Middle Aged , Reproducibility of Results , Norway , Time Factors , Mobile Applications , Treatment Outcome , Electrocardiography, Ambulatory/instrumentation , Telemetry/instrumentation , Cardiac Surgical Procedures/adverse effects , Wearable Electronic Devices , Electrocardiography , Heart Valves/surgery , Heart Valves/physiopathology
16.
Medicine (Baltimore) ; 103(21): e38206, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38788025

ABSTRACT

OBJECTIVE: To evaluate left atrial volume and function in patients with paroxysmal atrial fibrillation (AF) combined with left atrial appendage thrombosis and patients with paroxysmal AF without left atrial appendage thrombosis by 3-dimensional speckle tracking imaging (3D-STI), and to explore the application value of this set of parameters in the evaluation of left atrial function in patients with paroxysmal AF. MATERIALS AND METHODS: A total of 40 patients with paroxysmal AF admitted from December 2018 to December 2020 were selected as the observation group. All patients with paroxysmal AF in the observation group underwent transesophageal echocardiography. According to the presence of left atrial appendage thrombosis, the patients were divided into the AF without thrombosis group (24 cases) and the AF with thrombosis group (16 cases). Thirty normal people were selected as control group who were chosen as having no heart-related disease. The left atrial volume parameters (Left atrial maximum volume LAVmax, Left atrial minimum volume LAVmin, Left atrial volume before atrial contraction LAVpre-A, Left atrial stroke volume LAEV), left atrial ejection fraction (LAEF) and left atrial strain parameters (Left atrial reservoir longitudinal strain LASr, Left atrial conduit longitudinal strain LAScd, Left atrial contraction longitudinal strain LASct, Left atrial reservoir circumferential strain LASr-c, Left atrial conduit circumferential strain LAScd-c, Left atrial contraction circumferential strain LASct-c) of the 3 groups were measured by 3D-STI. RESULTS: With the progression of paroxysmal AF, the left atrial volume increased, and the reservoir, conduit and contractile function were damaged. The left atrial volume continued to increase, and the reservoir, conduit and contractile function further decreased significantly in patients with AF combined with left atrial appendage thrombosis. LAEF was positively correlated with LASr and LASr_c. CONCLUSION: Real-time 3-dimensional spot tracking imaging (3D-STI) can evaluate the changes in left atrial volume and function in patients with paroxysmal AF, and has a certain reference value for clinical judgment of disease progression and prognosis.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Function, Left , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Male , Female , Middle Aged , Atrial Function, Left/physiology , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Echocardiography, Three-Dimensional/methods , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Echocardiography, Transesophageal/methods , Aged , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/physiopathology
17.
Nat Commun ; 15(1): 4304, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773065

ABSTRACT

Increased left atrial volume and decreased left atrial function have long been associated with atrial fibrillation. The availability of large-scale cardiac magnetic resonance imaging data paired with genetic data provides a unique opportunity to assess the genetic contributions to left atrial structure and function, and understand their relationship with risk for atrial fibrillation. Here, we use deep learning and surface reconstruction models to measure left atrial minimum volume, maximum volume, stroke volume, and emptying fraction in 40,558 UK Biobank participants. In a genome-wide association study of 35,049 participants without pre-existing cardiovascular disease, we identify 20 common genetic loci associated with left atrial structure and function. We find that polygenic contributions to increased left atrial volume are associated with atrial fibrillation and its downstream consequences, including stroke. Through Mendelian randomization, we find evidence supporting a causal role for left atrial enlargement and dysfunction on atrial fibrillation risk.


Subject(s)
Atrial Fibrillation , Deep Learning , Genome-Wide Association Study , Heart Atria , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/genetics , Atrial Fibrillation/diagnostic imaging , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Heart Atria/pathology , Male , Female , Middle Aged , Aged , Magnetic Resonance Imaging , Mendelian Randomization Analysis , Risk Factors , Atrial Function, Left/physiology , Stroke Volume , Stroke , United Kingdom/epidemiology , Genetic Loci , Genetic Predisposition to Disease
18.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730404

ABSTRACT

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Subject(s)
Atrial Fibrillation , Bradycardia , Cardiac Pacing, Artificial , Catheter Ablation , Heart Rate , Pacemaker, Artificial , Recurrence , Humans , Male , Female , Middle Aged , Catheter Ablation/adverse effects , Prospective Studies , Treatment Outcome , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Atrial Fibrillation/surgery , Bradycardia/diagnosis , Bradycardia/therapy , Bradycardia/physiopathology , Cardiac Pacing, Artificial/adverse effects , Time Factors , Risk Factors , Syndrome , Tachycardia/physiopathology , Tachycardia/diagnosis , Tachycardia/therapy , Tachycardia/surgery
20.
Sci Rep ; 14(1): 11427, 2024 05 19.
Article in English | MEDLINE | ID: mdl-38763959

ABSTRACT

Despite the key role of fibrosis in atrial fibrillation (AF), the effects of different spatial distributions and textures of fibrosis on wave propagation mechanisms in AF are not fully understood. To clarify these aspects, we performed a systematic computational study to assess fibrosis effects on the characteristics and stability of re-entrant waves in electrically-remodelled atrial tissues. A stochastic algorithm, which generated fibrotic distributions with controlled overall amount, average size, and orientation of fibrosis elements, was implemented on a monolayer spheric atrial model. 245 simulations were run at changing fibrosis parameters. The emerging propagation patterns were quantified in terms of rate, regularity, and coupling by frequency-domain analysis of correspondent synthetic bipolar electrograms. At the increase of fibrosis amount, the rate of reentrant waves significantly decreased and higher levels of regularity and coupling were observed (p < 0.0001). Higher spatial variability and pattern stochasticity over repetitions was observed for larger amount of fibrosis, especially in the presence of patchy and compact fibrosis. Overall, propagation slowing and organization led to higher stability of re-entrant waves. These results strengthen the evidence that the amount and spatial distribution of fibrosis concur in dictating re-entry dynamics in remodeled tissue and represent key factors in AF maintenance.


Subject(s)
Atrial Fibrillation , Computer Simulation , Fibrosis , Heart Atria , Models, Cardiovascular , Humans , Heart Atria/physiopathology , Heart Atria/pathology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/pathology , Algorithms
SELECTION OF CITATIONS
SEARCH DETAIL
...