Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.254
Filter
1.
J Cardiothorac Surg ; 19(1): 296, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778360

ABSTRACT

BACKGROUND: There is little literature on the use of temporary pacemakers in children with fulminant myocarditis. Therefore, we summarized the use of temporary cardiac pacemakers in children with fulminant myocarditis in our hospital. METHODS: The clinical data of children with fulminant myocarditis treated with temporary pacemakers in Wuhan Children's Hospital from January 2017 to May 2022 were retrospectively analyzed. RESULTS: A total of 6 children were enrolled in the study, including 4 boys and 2 girls, with a median age of 50 months and a median weight of 15 kg. The average time from admission to pacemaker placement was 2.75 ± 0.4 h. The electrocardiogram showed that all 6 children had third-degree atrioventricular block (III°AVB). The initial pacing voltage, the sensory sensitivity of the ventricle and the pacing frequency were set to 5-10 mV, 5 V and 100-120 bpm respectively. The sinus rhythm was recovered in 5 patients within 61 h (17-134) h, and the median time of using temporary pacemaker was 132 h (63-445) h. One of the children had persistent III°AVB after the temporary pacemaker. With parental consent, the child was fitted with a permanent pacemaker on the 12th day of his illness. CONCLUSIONS: When fulminant myocarditis leads to severe bradycardia or atrioventricular block in children, temporary pacemakers have the characteristics of high safety to improve the heart function.


Subject(s)
Atrioventricular Block , Myocarditis , Pacemaker, Artificial , Humans , Myocarditis/therapy , Myocarditis/physiopathology , Male , Female , Child, Preschool , Retrospective Studies , Child , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Infant , Electrocardiography , Cardiac Pacing, Artificial/methods , Bradycardia/therapy , Bradycardia/physiopathology , Treatment Outcome
2.
Med Sci Monit ; 30: e944114, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38776271

ABSTRACT

BACKGROUND Long-term right ventricular (RV) pacing has been linked to left atrial enlargement (LAE). The incidence and risk factors associated with significant LAE after RV pacing remain unknown. This retrospective study included 461 patients requiring RV pacing at 2 centers between 2012 and 2020 and aimed to evaluate the incidence, risk factors, outcomes, and complications of LAE. MATERIAL AND METHODS A total of 461 patients with normal-sized pre-implant left atrial dimension and dual-chamber pacing pacemaker implantation for complete atrioventricular block were enrolled. Patients were grouped based on a ≥20% increase from their baseline left atrial dimension by echocardiography, indicating significant LAE, and initial characteristics, echocardiographic data, and outcomes were compared. RESULTS During a mean 7.0±4.9 years follow-up period, 96 patients (20.8%) developed significant LAE, whereas 365 patients did not. In multivariate logistic regression analysis, smaller pre-implant left atrial dimension (OR, 0.776; 95% CI, 0.728-0.828; P<0.001), lower post-implant left ventricular ejection fraction (OR, 0.976; 95% CI, 0.957-0.995; P=0.014), post-implant development of moderate to severe mitral regurgitation (OR, 2.357; 95% CI, 1.172-4.740; P=0.016), and RV pacing duration ≥3.3 years (OR, 1.576; 95% CI, 1.039-2.646; P=0.045) were independent predictors of significant LAE after RV-dependent pacing. There was a significant difference in the incident stroke events between patients without and with significant LAE (9.9% vs 17.7%; log-rank P=0.047). CONCLUSIONS Long-term RV pacing was linked to significant LAE in 20.8% of patients with complete atrioventricular block, with those affected experiencing a higher stroke rate during follow-up.


Subject(s)
Cardiac Pacing, Artificial , Echocardiography , Heart Atria , Heart Ventricles , Humans , Female , Male , Retrospective Studies , Risk Factors , Incidence , Aged , Heart Atria/physiopathology , Cardiac Pacing, Artificial/methods , Cardiac Pacing, Artificial/adverse effects , Middle Aged , Heart Ventricles/physiopathology , Echocardiography/methods , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Cardiomegaly/physiopathology , Pacemaker, Artificial , Treatment Outcome , Aged, 80 and over
4.
Curr Probl Cardiol ; 49(7): 102577, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38653441

ABSTRACT

BACKGROUND: There is a paucity of evidence on impact of a delay in Cardiac Sarcoidosis (CS) diagnosis after high-grade atrioventricular-block (AVB) and this study aims to fill this void. METHODS: Consecutive CS patients (n = 77) with high grade AVB referred to one specialist hospital in London between February 2007 to February 2023 were retrospectively reviewed. The median time from AVB to diagnosing CS (112 days) was used to define the Early (n = 38) and Late (n = 39) cohorts. The primary endpoint was a composite of all-cause mortality, cardiac transplantation, ventricular arrhythmic events or heart failure hospitalisation. Secondary endpoints included difference in maintenance prednisolone dose, need for cardiac device upgrade and device complications. RESULTS: The mean age of the cohort was 54.4 (±10.6) years of whom 64 % were male and 81 % Caucasian. After a mean follow up of 54.9 (±45.3) months, the primary endpoint was reached by more patients from the Late cohort (16/39 vs. 6/38, p = 0.02; multivariable HR 6.9; 95 %CI 1.5-32.2, p = 0.01). Early Group were more likely to have received an Implantable Cardioverter Defibrillator or Cardiac Resynchronisation Therapy-defibrillator as index device after AVB (19/38 vs. 6/39; p < 0.01) and had fewer device upgrades (19/38 vs. 30/39, p = 0.01) and a trend towards fewer device complications (1 vs. 5, p = 0.20). The maintenance dose of prednisolone was significantly higher in Late Group [20.7(±9.7) mg vs. 15.3(±7.9) mg, p = 0.02]. CONCLUSION: A late diagnosis of CS was associated with more adverse events, a greater probability of needing a device upgrade and required higher maintenance steroid dose.


Subject(s)
Atrioventricular Block , Cardiomyopathies , Sarcoidosis , Humans , Sarcoidosis/diagnosis , Sarcoidosis/complications , Male , Female , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Middle Aged , Cardiomyopathies/diagnosis , Cardiomyopathies/therapy , Retrospective Studies , Time Factors , Early Diagnosis , London/epidemiology , Prednisolone/therapeutic use , Prednisolone/administration & dosage , Adult , Follow-Up Studies , Aged
5.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38564374

ABSTRACT

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Young Adult , Adult , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial/adverse effects , Heart Conduction System , Heart Ventricles , Treatment Outcome
6.
J Am Heart Assoc ; 13(9): e032777, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639357

ABSTRACT

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.


Subject(s)
Aortic Valve Stenosis , Bundle-Branch Block , Cardiac Pacing, Artificial , Electrocardiography , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology , Bundle-Branch Block/diagnosis , Aortic Valve Stenosis/surgery , Aged, 80 and over , Aged , Cardiac Pacing, Artificial/adverse effects , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Atrioventricular Block/diagnosis , Atrioventricular Block/physiopathology , Risk Factors , Retrospective Studies , Treatment Outcome , Time Factors , Postoperative Complications/etiology , Postoperative Complications/therapy , Postoperative Complications/diagnosis , Recurrence
7.
Lakartidningen ; 1212024 Apr 09.
Article in Swedish | MEDLINE | ID: mdl-38595090

ABSTRACT

In elderly patients high-degree atrioventricular (AV) block is often due to irreversible degeneration of the cardiac conduction system. Reversible causes must however be excluded prior to pacemaker implantation. In younger patients reversible causes are more likely, as well as more unusual etiologies. Lyme carditis is a rare, but reversible cause of AV block. It is a manifestation of Lyme borreliosis - an infectious disease caused by the bacteria Borrelia burgdorferi. Lyme carditis should particularly be considered in young and middle-aged patients with a high-degree AV block. When pretest probability is intermediate to high, a positive serological test makes the diagnosis of Lyme carditis highly likely. In these cases antibiotic treatment may revert the conduction disturbance, thus preventing unnecessary implantation of a permanent pacemaker.


Subject(s)
Atrioventricular Block , Lyme Disease , Myocarditis , Middle Aged , Humans , Aged , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Myocarditis/diagnosis , Diagnosis, Differential , Lyme Disease/diagnosis , Anti-Bacterial Agents/therapeutic use , Electrocardiography
8.
Sci Rep ; 14(1): 7825, 2024 04 03.
Article in English | MEDLINE | ID: mdl-38570621

ABSTRACT

Diagnosing cardiac sarcoidosis (CS), especially in isolated cases, is challenging, particularly due to the limitations of endomyocardial biopsy, leading to potential undiagnosed cases in pacemaker-implanted patients. This study aims to provide real world findings to support new guideline for CS using 18F-fluoro-deoxyglucose positron-emission tomography computed tomography (FDG-PET/CT) which give a definite diagnosis of isolated CS (iCS) without histological findings. We examined consecutive patients with cardiac pacemakers for atrioventricular block (AV-b) attending our outpatient pacemaker clinic. The patients underwent periodical follow-up echocardiography and were divided into two groups according to echocardiographic findings: those with suspected CS and those without suspected CS. Patients suspected of having nonischemic cardiomyopathy underwent FDG-PET/CT for CS diagnosis. We investigated the utility of the new guideline for CS using FDG-PET/CT. Among the 272 patients enrolled, 97 patients were implanted with cardiac pacemakers for AV-b. Twenty-two patients were suspected of having CS during a median observation period of 5.4 years after pacemaker implantation. Of these, one did not consent, and nine of 21 cases (43%) were diagnosed with definite CS according to the new guidelines. Five of these nine patients were diagnosed with iCS using FDG-PET/CT. The number of patients diagnosed with definite CS using the new guidelines tended to be approximately 2.3 times that of the conventional criteria (p = 0.074). Three of the nine patients underwent steroid treatment. The composite outcome, comprising all-cause death, heart failure hospitalization, and a substantial reduction in left ventricular ejection fraction, were significantly lower in patients receiving steroid treatment compared to those without steroid treatment (p = 0.048). The utilization of FDG-PET/CT in accordance with the new guidelines facilitates the diagnosis of CS, including iCS, resulting in approximately 2.3 times as many diagnoses of CS compared to the conventional criteria. This guideline has the potential to support the early identification of iCS and may contribute to enhancing patient clinical outcomes.


Subject(s)
Atrioventricular Block , Cardiomyopathies , Myocarditis , Sarcoidosis , Humans , Positron Emission Tomography Computed Tomography , Fluorodeoxyglucose F18 , Atrioventricular Block/diagnostic imaging , Atrioventricular Block/therapy , Stroke Volume , Radiopharmaceuticals , Positron-Emission Tomography/methods , Ventricular Function, Left , Cardiomyopathies/pathology , Sarcoidosis/diagnostic imaging , Sarcoidosis/pathology , Steroids , Retrospective Studies
9.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38449430

ABSTRACT

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Pacing, Artificial/adverse effects , Arrhythmias, Cardiac/therapy , Heart Rate/physiology
10.
J Cardiovasc Electrophysiol ; 35(5): 906-915, 2024 May.
Article in English | MEDLINE | ID: mdl-38433355

ABSTRACT

INTRODUCTION: Right ventricular (RV) pacing sometimes causes left ventricular (LV) systolic dysfunction, also known as pacing-induced cardiomyopathy (PICM). However, the association between specifically paced QRS morphology and PICM development has not been elucidated. This study aimed to investigate the association between paced QRS mimicking a complete left bundle branch block (CLBBB) and PICM development. METHODS: We retrospectively screened 2009 patients who underwent pacemaker implantation from 2010 to 2020 in seven institutions. Patients who received pacemakers for an advanced atrioventricular block or bradycardia with atrial fibrillation, baseline LV ejection fraction (LVEF) ≥ 50%, and echocardiogram recorded at least 6 months postimplantation were included. The paced QRS recorded immediately after implantation was analyzed. A CLBBB-like paced QRS was defined as meeting the CLBBB criteria of the American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society in 2009. PICM was defined as a ≥10% LVEF decrease, resulting in an LVEF of <50%. RESULTS: Among the 270 patients analyzed, PICM was observed in 38. Baseline LVEF was lower in patients with PICM, and CLBBB-like paced QRS was frequently observed in PICM. Multivariate analysis revealed that low baseline LVEF (odds ratio [OR]: 0.93 per 1% increase, 95% confidence interval [CI]: 0.89-0.98, p = 0.006) and CLBBB-like paced QRS (OR: 2.69, 95% CI: 1.25-5.76, p = 0.011) were significantly associated with PICM development. CONCLUSION: CLBBB-like paced QRS may be a novel risk factor for PICM. RV pacing, which causes CLBBB-like QRS morphology, may need to be avoided, and patients with CLBBB-like paced QRS should be followed-up carefully.


Subject(s)
Action Potentials , Bundle-Branch Block , Cardiac Pacing, Artificial , Cardiomyopathies , Electrocardiography , Heart Rate , Predictive Value of Tests , Stroke Volume , Ventricular Function, Left , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Atrioventricular Block/physiopathology , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Bundle-Branch Block/physiopathology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Bundle-Branch Block/etiology , Cardiac Pacing, Artificial/adverse effects , Cardiomyopathies/physiopathology , Cardiomyopathies/etiology , Cardiomyopathies/therapy , Cardiomyopathies/diagnosis , Diagnosis, Differential , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Ventricular Function, Right
11.
Medicina (Kaunas) ; 60(3)2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38541230

ABSTRACT

Background and Objectives: Atrioventricular (AV) dyssynchrony as well as atrial and ventricular pacing affect left atrial (LA) function. We conducted a study evaluating the effect of atrial and ventricular pacing on LA morphological and functional changes after dual-chamber pacemaker implantation. Materials and Methods: The study prospectively enrolled 121 subjects who had a dual-chamber pacemaker implanted due to sinus node disease (SND) or atrioventricular block (AVB). Subjects were divided into three groups based on indication and pacemaker programming: (1) SND DDDR 60; (2) AVB DDD 60 and (3) AVB DDD 40. Subjects were invited to one- and three-month follow-up visits. Three subsets based on pacing burden were analyzed: (1) high atrial (A) low ventricular (V); (2) high A, high V and (3) low A, high V. LA function was assessed from volumetric parameters and measured strains from echocardiography. Results: The high A, low V group consisted of 38 subjects; while high A, high V had 26 and low A, high V had 23. A significant decrease in reservoir and contractile LA strain parameters were only observed in the high A, low V pacing group after three months (reservoir 25.9 ± 10.3% vs. 21.1 ± 9.9%, p = 0.003, contractile -14.0 ± 9.0% vs. -11.1 ± 7.8, p = 0.018). While the re-established atrioventricular synchrony in the low A, high V group maintained reservoir LA strain at the baseline level after three months (21.4 ± 10.4% vs. 22.5 ± 10.4%, p = 0.975); in the high A, high V group, a further trend to decrease was noted (20.3 ± 8.9% vs. 18.7 ± 8.3%, p = 0.231). Conclusions: High atrial pacing burden independently of atrioventricular dyssynchrony and ventricular pacing impairs LA functional and morphological parameters. Changes appear soon after pacemaker implantation and are maintained.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Cardiac Pacing, Artificial/adverse effects , Heart Atria , Sick Sinus Syndrome/therapy , Atrioventricular Block/therapy
12.
Open Heart ; 11(1)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38538064

ABSTRACT

OBJECTIVE: Transthyretin amyloid cardiomyopathy (ATTR-CM) is an infiltrative cardiac disorder caused by deposition of wild type or mutated transthyretin. As ATTR-CM is associated with conduction disease, we sought to determine its prevalence in patients with idiopathic high-degree atrioventricular (AV) block requiring permanent pacemaker (PPM) implantation. METHODS: Consecutive patients aged 70-85 years undergoing PPM implantation for idiopathic high-degree AV block between November 2019 and November 2021 were offered a 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scan. Demographics, comorbidities, electrocardiographic and imaging data from the time of device implantation were retrospectively collected. RESULTS: 39 patients (79.5% male, mean (SD) age at device implantation 76.2 (2.9) years) had a DPD scan. 3/39 (7.7%, all male) had a result consistent with ATTR-CM (Perugini grade 2 or 3). Mean (SD) maximum wall thickness of those with a positive DPD scan was 19.0 mm (3.6 mm) vs 11.4 mm (2.7 mm) in those with a negative scan (p=0.06). All patients diagnosed with ATTR-CM had spinal canal stenosis and two had carpal tunnel syndrome. CONCLUSIONS: ATTR-CM should be considered in older patients requiring permanent pacing for high-degree AV block, particularly in the presence of left ventricular hypertrophy, carpal tunnel syndrome or spinal canal stenosis.


Subject(s)
Amyloidosis , Atrioventricular Block , Carpal Tunnel Syndrome , Humans , Male , Aged , Female , Atrioventricular Block/diagnosis , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , Retrospective Studies , Prevalence , Prealbumin , Carpal Tunnel Syndrome/complications , Constriction, Pathologic/complications
13.
Pacing Clin Electrophysiol ; 47(5): 635-641, 2024 May.
Article in English | MEDLINE | ID: mdl-38552167

ABSTRACT

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.


Subject(s)
Pacemaker, Artificial , Humans , Male , Female , Retrospective Studies , Child , Child, Preschool , Electrodes, Implanted , Atrioventricular Block/therapy , Sick Sinus Syndrome/therapy
14.
Pediatr Cardiol ; 45(4): 759-769, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38427091

ABSTRACT

Postoperative atrioventricular block may occur after pediatric cardiac surgery. A small proportion of those who develop atrioventricular block will require pacemaker placement. The primary aim of this study was to determine factors associated with postoperative atrioventricular block. Secondary aims included determining factors associated with pacemaker placement in those with atrioventricular block. Data from the PHIS data were utilized to identify patients under 18 years of age who underwent cardiac surgery. Those who did and did not develop atrioventricular block. Univariable analyses and regression analyses were conducted to determine factors associated with postoperative atrioventricular block. Similar analyses were conducted to determine factors associated with pacemaker placement in those with atrioventricular block. A total of 43,716 admissions were identified. Of these, 2093 (5%) developed atrioventricular block and 480 (1% of total admissions) underwent pacemaker placement. Approximately 70% of those with atrioventricular block received steroids but this was not associated with a decrease in pacemaker placement. Risk factors (congenital malformations of the heart, comorbidities, medications) associated with increased risk of atrioventricular block and pacemaker placement were identified. Postoperative atrioventricular block occurred in 5% of pediatric admissions for cardiac surgery. Of these admissions with postoperative atrioventricular block, 23% required pacemaker placement. Isoproterenol and steroids were not associated with a reduction in the likelihood of pacemaker placement.


Subject(s)
Atrioventricular Block , Cardiac Surgical Procedures , Heart Defects, Congenital , Pacemaker, Artificial , Child , Humans , Adolescent , Atrioventricular Block/epidemiology , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Pacemaker, Artificial/adverse effects , Cardiac Surgical Procedures/adverse effects , Heart Defects, Congenital/complications , Postoperative Complications/etiology , Steroids
15.
J Am Heart Assoc ; 13(4): e032223, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38348803

ABSTRACT

BACKGROUND: Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study. METHODS AND RESULTS: In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs. We analyzed all Holter ECGs for the presence of the following incidental arrhythmias: (1) sinus node dysfunction, defined as sinus pause of ≥3 seconds' duration; (2) second-degree (including Wenckebach) or higher-degree atrioventricular block (AVB); (3) sustained supraventricular tachycardia of ≥30 seconds' duration; and (4) sustained ventricular tachycardia of ≥30 seconds' duration. We furthermore report treatment decisions because of incidental arrhythmias. A total of 2077 Holter ECGs were performed in 794 patients (mean age, 74.7 years; 49% women), resulting in a mean cumulative duration of analyzable ECG signal of 414±136 hours/patient. We found incidental arrhythmias in 94 patients (11.8%). Among these were sinus node dysfunction in 14 patients (1.8%), AVB in 41 (5.2%), supraventricular tachycardia in 42 (5.3%), and ventricular tachycardia in 2 (0.3%). Second-degree AVB was found in 23 patients (2.9%), 2:1 AVB in 10 (1.3%), and complete AVB in 8 (1%). Subsequently, 8 patients underwent pacemaker implantation, 1 for sinus node dysfunction (post-AF conversion pause of 9 seconds) and 7 for advanced AVB. One patient had an implantable cardioverter-defibrillator implanted for syncopal ventricular tachycardia. CONCLUSIONS: Incidental arrhythmias were frequently detected during screening for AF in the STAR-FIB study and resulted in device therapy in 1.1% of our cohort patients.


Subject(s)
Atrial Fibrillation , Atrioventricular Block , Defibrillators, Implantable , Tachycardia, Supraventricular , Tachycardia, Ventricular , Humans , Female , Aged , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Electrocardiography, Ambulatory , Cohort Studies , Sick Sinus Syndrome , Atrioventricular Block/diagnosis , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , Tachycardia, Supraventricular/diagnosis , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Hospitals
16.
J Cardiovasc Electrophysiol ; 35(4): 846-847, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38348495

ABSTRACT

The year 2024 marks the centenary of Mobitz's description of type II second-degree atrioventricular block. Its definition remains valid to this day with only minor modification for the diagnosis of infranodal conduction block. Mobitz a century ago indicated that his type II atrioventricular block was associated with Stock-Adams attacks and a prolonged duration of the QRS complex before the eventual description of bundle branch block.


Subject(s)
Atrioventricular Block , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Electrocardiography , Bundle-Branch Block/diagnosis , Bundle of His
17.
BMC Cardiovasc Disord ; 24(1): 73, 2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38267846

ABSTRACT

BACKGROUND: The systemic immune-inflammation index (SII), based on white blood cell, neutrophil, and platelet counts, is a proposed marker of systemic inflammation and immune activation. This study aimed to explore the relationship between SII and complete atrioventricular block (CAVB) development in STEMI patients undergoing primary PCI. METHODS: We retrospectively analyzed data from 883 patients who underwent primary PCI for STEMI between January 2009 and December 2017. Patients were categorized into two groups based on CAVB development. SII levels were calculated from blood samples taken on admission. RESULTS: Of the included patients, 48 (5.03%) developed CAVB. SII was higher in patients with CAVB compared to those without CAVB (1370 [1050-1779]x109/L vs. 771 [427-1462] x109/L, p < 0.001). Multivariate analysis showed a significant positive correlation between SII and the risk of CAVB development (OR:1.0003, 95%CI:1.0001-1.0005, P = 0.044). The cut-off value for the SII in the estimation of CAVB was 1117.7 × 109/L (area under the ROC curve [AUC]: 0.714, 95% CI = 0.657-0.770 with a sensitivity of 70.8% and specificity of 65.6%, p < 0.001). CONCLUSION: This study showed a significant link between high SII levels and CAVB development in STEMI patients undergoing PCI. Our findings suggest that SII may be a valuable, routinely available, and inexpensive marker for identifying patients at increased risk of CAVB.


Subject(s)
Atrioventricular Block , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Percutaneous Coronary Intervention/adverse effects , Retrospective Studies , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/therapy , Inflammation/diagnosis
18.
J Int Med Res ; 52(1): 3000605231223040, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38206211

ABSTRACT

Atrioventricular block (AVB) is a rare cardiac manifestation of hyperthyroidism (HTH). The scientific literature contains multiple reports of AVB in patients with HTH, ranging from subclinical to overt HTH and even thyroid storm. However, much remains unknown about the true prevalence, clinical course, optimal management, and outcomes of AVB in patients with HTH. Such patients are possibly overtreated with pacemakers because of a lack of understanding that AVB might be secondary to the hyperthyroid state and thus reversible. This narrative review discusses the pathophysiology of AVB in patients with HTH in the context of the available evidence.


Subject(s)
Atrioventricular Block , Hyperthyroidism , Humans , Atrioventricular Block/complications , Atrioventricular Block/therapy , Hyperthyroidism/complications , Patients , Heart
19.
BMC Cardiovasc Disord ; 24(1): 77, 2024 Jan 28.
Article in English | MEDLINE | ID: mdl-38281925

ABSTRACT

BACKGROUND: New-generation self-expanding valves can improve the success rate of transcatheter aortic valve replacement (TAVR) for severe pure native aortic regurgitation (PNAR). However, predictors of new-onset conduction block post-TAVR using new-generation self-expanding valves in patients with PNAR remain to be established. Therefore, this study aimed to identify predictors of new-onset conduction block post-TAVR using new-generation self-expanding valves (VitaFlow Liberty™) in patients with PNAR. METHODS: In this retrospective cohort study, patients were categorized into pacemaker and non-pacemaker groups based on their need for new postoperative permanent pacemaker implantation (PPI). Based on the postoperative presence of either new-onset complete left bundle branch block (cLBBB) or high-grade atrioventricular block (AVB), patients were further classified into conduction disorder and non-conduction disorder groups. Laboratory, echocardiographic, computed tomography, preoperative and postoperative electrocardiography, and procedural and clinical data were collected immediately after TAVR and during hospitalization and compared between the groups. Multivariate logistic regression analysis was performed incorporating the significant variables from the univariate analyses. RESULTS: This study examined 68 consecutive patients with severe PNAR who underwent TAVR. In 20 patients, a permanent pacemaker was fitted postoperatively. Multivariate logistic regression analysis revealed an association between the need for postoperative PPI and preoperative complete right bundle branch block (cRBBB) or first-degree AVB, as well as a non-tubular left ventricular outflow tract (LVOT). In addition, valve implantation depth and angle of aortic root were independent predictors of new-onset cLBBB or high-grade AVB developing post-TAVR. The predictive value of valve implantation depth and angle of aortic root was further supported by receiver operating characteristic curve analysis results. CONCLUSIONS: In patients with PNAR undergoing TAVR using self-expanding valves, preoperative cRBBB or first-degree AVB and a non-tubular LVOT were indicators of a higher likelihood of PPI requirement. Moreover, deeper valve implantation depth and greater angle of aortic root may be independent risk factors for new-onset cLBBB or high-grade AVB post-TAVR. Valve implantation depth and angle of aortic root values may be used to predict the possibility of new cLBBB or high-grade AVB post-TAVR.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Atrioventricular Block , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Retrospective Studies , Cardiac Pacing, Artificial/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Pacemaker, Artificial/adverse effects , Arrhythmias, Cardiac , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
20.
Future Cardiol ; 20(1): 21-25, 2024 01.
Article in English | MEDLINE | ID: mdl-38223918

ABSTRACT

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Subject(s)
Atrioventricular Block , Heart Septal Defects , Pacemaker, Artificial , Humans , Heart Ventricles/diagnostic imaging , Cardiac Pacing, Artificial/methods , Atrioventricular Block/therapy , Heart Atria/diagnostic imaging
SELECTION OF CITATIONS