Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 14.658
Filter
1.
Medicina (Kaunas) ; 60(5)2024 May 13.
Article in English | MEDLINE | ID: mdl-38792986

ABSTRACT

Background and Objectives: Besides classical stapedotomy, reverse stapedotomy has been used for many years in the management of otosclerosis. Our study aims to investigate whether reversing the surgical steps in stapedotomy impacts vestibular function and hearing improvement. Materials and Methods: A cohort of 123 patients underwent either classic or reverse stapedotomy procedures utilizing a fiber-optic argon laser. Audiological assessments, following the guidelines of the Committee on Hearing and Equilibrium, were conducted, including pure tone average, air-bone (AB) gap, overclosure, and AB gap closure. Vestibular evaluation involved pre- and postoperative comparison of rotatory test parameters, including frequency, amplitude, and slow phase velocity of nystagmus. Results: The study demonstrated an overall median overclosure of 3.3 (3.3, 5.0) dB and a mean AB gap closure of 20.3 ± 8.8 dB. Postoperative median AB gap was 7.5 (7.5, 11.3) dB in the reverse stapedotomy group and 10.0 (10.0, 12.5) dB in the classic stapedotomy group. While overclosure and AB gap closure were marginally superior in the reverse stapedotomy group, these differences did not reach statistical significance. No significant disparities were observed in the frequency, slow phase velocity, or amplitude of nystagmus in the rotational test. Conclusions: Although not always possible, reverse stapedotomy proved to be a safe surgical technique regarding postoperative outcomes. Its adoption may mitigate risks associated with floating footplate, sensorineural hearing loss, and incus luxation/subluxation, while facilitating the learning curve for less experienced ear surgeons.


Subject(s)
Otosclerosis , Stapes Surgery , Humans , Stapes Surgery/methods , Stapes Surgery/adverse effects , Male , Female , Middle Aged , Adult , Otosclerosis/surgery , Otosclerosis/physiopathology , Audiometry/methods , Cohort Studies , Treatment Outcome , Audiometry, Pure-Tone/methods , Aged , Vestibular Function Tests/methods
2.
Trends Hear ; 28: 23312165241242235, 2024.
Article in English | MEDLINE | ID: mdl-38738302

ABSTRACT

The objective of this project was to establish cutoff scores on the tinnitus subscale of the Tinnitus and Hearing Survey (THS) using a large sample of United States service members (SM) with the end goal of guiding clinical referrals for tinnitus evaluation. A total of 4,589 SM undergoing annual audiometric surveillance were prospectively recruited to complete the THS tinnitus subscale (THS-T). A subset of 1,304 participants also completed the Tinnitus Functional Index (TFI). The original 5-point response scale of the THS (THS-T16) was modified to an 11-point scale (THS-T40) for some participants, to align with the response scale of the TFI. Age, sex, hearing loss, and self-reported tinnitus bother were also recorded. The THS-T was relatively insensitive to hearing, but self-reported bothersome tinnitus was significantly associated with the THS-T40 score. Receiver operating characteristic analysis was used to determine cutoff scores on the THS-T that aligned with recommended cutoff values for clinical intervention on the TFI. A cutoff of 9 on the THS-T40 aligns with a TFI cutoff of 25, indicating a patient may need intervention for tinnitus. A cutoff of 15 aligns with a TFI cutoff of 50, indicating that more aggressive intervention for tinnitus is warranted. The THS-T is a viable tool to identify patients with tinnitus complaints warranting clinical evaluation for use by hearing conservation programs and primary care clinics. The THS-T40 cutoff scores of 9 and 15 provide clinical reference points to guide referrals to audiology.


Subject(s)
Tinnitus , Humans , Tinnitus/diagnosis , Female , Male , Middle Aged , Aged , Adult , Prospective Studies , United States , Hearing , Predictive Value of Tests , Reproducibility of Results , Severity of Illness Index , ROC Curve , Surveys and Questionnaires , Self Report , Audiometry/methods
3.
Am Fam Physician ; 109(4): 316-323, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38648830

ABSTRACT

Hearing loss is a prevalent, chronic condition in the United States; it is often gradual and progressive and is underreported by patients and undertreated by physicians. The impaired ability to effectively hear and communicate may result in negative emotional, cognitive, economic, and social consequences for individuals and may pose a safety risk. Questionnaires and smartphone apps are available to help identify and evaluate self-perceived hearing loss. Physicians should assess for objective hearing impairment when the patient or family member raises a concern or if cognitive or mood symptoms are present that could be influenced by hearing loss. Three types of hearing loss exist: conductive, sensorineural, and mixed. Pure-tone audiometry uses an audiometer and is reported on an audiogram; it is the most accurate method for hearing loss detection. It can be used for screening or comprehensive testing when combined with tympanometry, speech-reception thresholds, and word-recognition testing. Audiograms that show a unilateral or asymmetrical sensorineural hearing loss can be signs of retrocochlear pathology and warrant additional evaluation by an audiologist and otolaryngologist as well as imaging studies. Medicare Parts A and B do not pay for hearing aids, although some Medicare Advantage (Part C) or supplemental plans may provide insurance coverage for hearing aids. Less expensive, over-the-counter hearing aids may help mild to moderate hearing loss. Family physicians should counsel patients on the importance of protecting their hearing.


Subject(s)
Hearing Loss , Humans , Hearing Loss/diagnosis , Adult , United States , Audiometry, Pure-Tone/methods , Audiometry/methods
4.
Otol Neurotol ; 45(4): 430-433, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38437820

ABSTRACT

OBJECTIVE: To describe the experience and results from coordinated and closely scheduled radiosurgery and cochlear implantation (CI) in a vestibular schwannoma (VS) cohort. PATIENTS: Patients with VS who underwent radiosurgery followed by CI on the same or next day. INTERVENTIONS: Interventions included sequential radiosurgery and CI. MAIN OUTCOME MEASURES: Tumor control defined by tumor growth on posttreatment surveillance and audiometric outcomes including consonant-nucleus-consonant words and AzBio sentences in quiet. RESULTS: In total, six patients were identified that met the inclusion criteria, with an age range of 38 to 69 years and tumor sizes ranging from 2.0 to 16.3 mm. All patients successfully underwent radiosurgery and CI on the same or immediately successive day. Postoperatively, all patients obtained open-set speech recognition. Consonant-nucleus-consonant word scores ranged from 40 to 88% correct, and AzBio scores ranged from 44 to 94% correct. During posttreatment magnetic resonance imaging surveillance, which ranged from 12 to 68 months, all tumors were noted to be adequately visualized, and no tumor progression was noted. CONCLUSION: Coordinated radiosurgery and CI can be safely performed in patients with VS on the same or next day, serving to decrease burden on patients and increase access to this vital rehabilitative strategy.


Subject(s)
Cochlear Implantation , Cochlear Implants , Neuroma, Acoustic , Radiosurgery , Speech Perception , Humans , Adult , Middle Aged , Aged , Cochlear Implantation/methods , Neuroma, Acoustic/surgery , Radiosurgery/methods , Retrospective Studies , Audiometry , Treatment Outcome
5.
Trends Hear ; 28: 23312165241240353, 2024.
Article in English | MEDLINE | ID: mdl-38545653

ABSTRACT

Exposure to intense low-frequency sounds, for example inside tanks and armoured vehicles, can lead to noise-induced hearing loss (NIHL) with a variable audiometric pattern, including low- and mid-frequency hearing loss. It is not known how well existing methods for diagnosing NIHL apply in such cases. Here, the audiograms of 68 military personnel (mostly veterans) who had been exposed to intense low-frequency noise (together with other types of noise) and who had low-frequency hearing loss (defined as a pure-tone average loss at 0.25, 0.5 and 1 kHz ≥20 dB) were used to assess the sensitivity of three diagnostic methods: the method of Coles, Lutman and Buffin, denoted CLB, which depends on the identification of a notch or bulge in the audiogram near 4 kHz, and two methods specifically intended for diagnosing NIHL sustained during military service, the rM-NIHL method, which depends on the identification of a notch or bulge in the audiogram near 4 kHz and/or a hearing loss at high frequencies greater than expected from age alone, and the MLP(18) method based on a multi-layer perceptron. The proportion of individuals receiving a positive diagnosis for either or both ears, which provides an approximate measure of sensitivity, was 0.40 for the CLB method, 0.79 for the rM-NIHL method and 1.0 for the MLP(18) method. It is concluded that the MLP(18) method is suitable for diagnosing NIHL sustained during military service whether or not the exposure includes intense low-frequency sounds.


Subject(s)
Deafness , Hearing Loss, Noise-Induced , Noise, Occupational , Humans , Hearing Loss, Noise-Induced/diagnosis , Hearing Loss, Noise-Induced/epidemiology , Hearing Loss, Noise-Induced/etiology , Audiometry/methods , Hearing Tests
6.
J Neurosurg Pediatr ; 33(5): 496-504, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38427998

ABSTRACT

OBJECTIVE: Pediatric data regarding treatment via an auditory brainstem implant (ABI) remains sparse. The authors aimed to describe their experience at their institution and to delineate associated demographic data, audiometric outcomes, and surgical parameters. METHODS: An IRB-approved, retrospective chart review was conducted among the authors' pediatric patients who had undergone auditory brainstem implantation between 2012 and 2021. Demographic information including sex, age, race, coexisting syndrome(s), history of cochlear implant placement, average duration of implant use, and follow-up outcomes were collected. Surgical parameters collected included approach, intraoperative findings, number of electrodes activated, and complications. RESULTS: A total of 19 pediatric patients had an ABI placed at the authors' institution, with a mean age at surgery of 4.7 years (range 1.5-17.8 years). A total of 17 patients (89.5%) had bilateral cochlear nerve aplasia/dysplasia, 1 (5.3%) had unilateral cochlear nerve aplasia/dysplasia, and 1 (5.3%) had a hypoplastic cochlea with ossification. A total of 11 patients (57.9%) had a history of cochlear implants that were ineffective and required removal. The mean length of implant use was 5.31 years (0.25-10 years). Two patients (10.5%) experienced CSF-related complications requiring further surgical intervention. The most recent audiometric outcomes demonstrated that 15 patients (78.9%) showed improvement in their hearing ability: 5 with sound/speech awareness, 5 able to discriminate among speech and environmental sounds, and 5 able to understand common phrases/conversation without lip reading. Nine patients (47.4%) are in a school for the deaf and 7 (36.8%) are in a mainstream school with support. CONCLUSIONS: The authors' surgical experience with a multidisciplinary team demonstrates that the retrosigmoid approach for ABI placement in children with inner ear pathologies and severe sensorineural hearing loss is a safe and effective treatment modality. Audiometric outcome data showed that nearly 79% of these patients had an improvement in their environmental and speech awareness. Further multicenter collaborations are necessary to improve these outcomes and potentially standardize/enhance electrode placement.


Subject(s)
Audiometry , Auditory Brain Stem Implantation , Humans , Child , Male , Female , Child, Preschool , Adolescent , Retrospective Studies , Infant , Auditory Brain Stem Implantation/methods , Treatment Outcome , Auditory Brain Stem Implants , Cochlear Nerve/surgery , Cochlear Nerve/abnormalities , Postoperative Complications/etiology , Postoperative Complications/epidemiology
7.
Clin Exp Rheumatol ; 42(4): 872-878, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38489315

ABSTRACT

OBJECTIVES: Neurosensory hearing loss is well-documented in chronic autoimmune conditions such as systemic lupus erythematosus (SLE). However, the literature lacks data on the prevalence and characteristics of hearing impairment in Takayasu's arteritis (TAK). In this cross-sectional study, our principal objective was to systematically assess the auditory function of individuals diagnosed with TAK, against SLE patients and healthy controls (HC). METHODS: Age and gender matched TAK and SLE patients followed up in a tertiary centre along with healthy controls were included in a two-phase study. In the first phase, a questionnaire on ENT symptoms was administered to the patient (TAK: n=104 and SLE: n= 151) and HC (n=174) groups. In the second phase, patients (TAK: n=53 and SLE: n=33) and HC (n=45) underwent audiometric tests. RESULTS: The questionnaire survey revealed that both TAK and SLE patients reported hearing loss (27.9%, 25.8%, 7.4%, p<0.001), tinnitus (49%, 35.8%, 13.8%, p<0.001) and vertigo (46.2%, 33.8%, 16.7%, p<0.001) at significantly higher rates than HC. Audiometry results indicated that both TAK (30.2%) and SLE patients (18.2%) had increased hearing loss compared to HC (8.9%), however, only TAK patients were found to have significantly increased risk in age adjusted logistic regression analysis (OR= 3.915, 95%CI: 1.179-12.998, p=0.026). Hearing loss was mainly neurosensory in all groups. TAK patients were affected at both low (<6000 Hz) and high (>6000 Hz) frequencies, whereas SLE patients were affected only at high frequencies. Hearing loss was significantly associated only with older age. No association was observed with the anatomical location of vascular involvement or history of stroke. CONCLUSIONS: Our study reveals an increased prevalence of hearing loss in TAK. Further research is crucial to uncover the underlying causes.


Subject(s)
Lupus Erythematosus, Systemic , Takayasu Arteritis , Tinnitus , Vertigo , Humans , Takayasu Arteritis/epidemiology , Takayasu Arteritis/complications , Takayasu Arteritis/diagnosis , Female , Male , Adult , Cross-Sectional Studies , Lupus Erythematosus, Systemic/complications , Lupus Erythematosus, Systemic/epidemiology , Lupus Erythematosus, Systemic/diagnosis , Prevalence , Middle Aged , Tinnitus/etiology , Tinnitus/epidemiology , Tinnitus/diagnosis , Surveys and Questionnaires , Case-Control Studies , Vertigo/etiology , Vertigo/epidemiology , Vertigo/physiopathology , Risk Factors , Hearing Loss/epidemiology , Hearing Loss/etiology , Hearing Loss/diagnosis , Young Adult , Logistic Models , Tertiary Care Centers , Hearing , Audiometry , Odds Ratio
8.
Int J Pediatr Otorhinolaryngol ; 179: 111925, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38552429

ABSTRACT

OBJECTIVE: The Baha SoundArc coupling system has been developed as a non-surgical coupling of a Baha sound processor to the skull allowing the transfer of vibrational energy to the cochlear partition via bone conduction pathways. Today, there are several alternatives to this non-surgical approach as the Baha headband/test band, or the Baha Softband, or adhesive patches. Each of these current options have benefits and liabilities. The aim of the study was to evaluate pediatric experience and performance when using two non-surgical options, the Baha SoundArc compared to the Baha Softband. METHODS: Twenty-five children with unilateral mixed or conductive hearing loss aged 5-12 years of age evaluated the use of the Baha SoundArc compared to their existing Baha Softband in a one month take home trial. Participants had a minimum of 3 months experience using the control, Baha Softband. Participants were assessed at baseline and one month following fit of the Baha SoundArc. Measures included an experience and use patient reported outcome, speech perception testing in quiet using Phonetically Balanced Kindergarten (PBK) words, and sound field audiometry. RESULTS: Mean aided soundfield thresholds across the frequency range were 27.6 dB HL for Softband and 26.0 dB HL for SoundArc, which were not significantly different (P = >.05). Mean word recognition score was 80.8% when aided with the Softband device and 85.1% with the SoundArc, which was also not significantly different (P = >.05). Most children favored the aesthetics and usability of the SoundArc over Softband, but comfort ratings were largely similar for both devices. CONCLUSIONS: Bone conduction sound processors mounted on a SoundArc or a Softband resulted in comparable improvements in aided thresholds and speech understanding in children suffering from conductive or mixed hearing loss. Both wearing modalities can be considered equivalent in terms of audiological outcomes, although both patients and clinicians preferred the usability and aesthetics of the SoundArc. The SoundArc provides an alternative wearing option for patients that may otherwise be discouraged by the aesthetics and usability of the Softband device. GOV IDENTIFIER: NCT03333577.


Subject(s)
Hearing Aids , Hearing Loss , Speech Perception , Humans , Child , Child, Preschool , Hearing Loss, Conductive/diagnosis , Hearing Loss, Conductive/therapy , Audiometry , Bone Conduction
9.
World Neurosurg ; 185: e549-e554, 2024 May.
Article in English | MEDLINE | ID: mdl-38382763

ABSTRACT

OBJECTIVE: This study aims to determine the prevalence of vestibular schwannoma (VS) among patients presenting with sudden hearing loss (SHL) and to characterize the clinical features of individuals diagnosed with both VS and SHL. METHODS: We conducted an observational retrospective review at a tertiary referral center, spanning a 30-year period, focusing on patients diagnosed with SHL where VS was confirmed as the underlying cause. We included patients meeting these criteria while excluding those lacking imaging or with a pre-existing diagnosis of VS. We evaluated the audiological characteristics at the time of diagnosis and assessed clinical outcomes following treatment. RESULTS: Among the 403 patients presenting with SHL during the study period, 9 (2.2%) were diagnosed with VS, aged between 25 and 72 years. Although audiometric profiles varied, high-frequency hearing loss predominated, mostly categorized as mild to moderate. Six patients (66%) had Koos grade I-II schwannomas. Only 2 patients achieved complete hearing recovery post-treatment, while 4 showed no improvement. CONCLUSIONS: VS is a rare etiology of SHL, accounting for slightly over 2% of cases. Its symptomatology, severity, and audiometric patterns do not significantly differ from SHL caused by other factors. Tumor size does not correlate with hearing characteristics. Treatment modalities resemble those for other SHL cases, and hearing improvement does not obviate the necessity for follow-up magnetic resonance imaging (MRI) scans.


Subject(s)
Hearing Loss, Sudden , Neuroma, Acoustic , Humans , Neuroma, Acoustic/complications , Neuroma, Acoustic/diagnostic imaging , Middle Aged , Female , Male , Adult , Hearing Loss, Sudden/etiology , Aged , Retrospective Studies , Audiometry
10.
Ear Hear ; 45(2): 486-498, 2024.
Article in English | MEDLINE | ID: mdl-38178308

ABSTRACT

OBJECTIVES: Audiometric testing typically does not include frequencies above 8 kHz. However, recent research suggests that extended high-frequency (EHF) sensitivity could affect hearing in natural communication environments. Clinical assessment of hearing often employs pure tones and frequency-modulated (FM) tones interchangeably regardless of frequency. The present study was designed to evaluate how the stimulus chosen to measure EHF thresholds affects estimates of hearing sensitivity. DESIGN: The first experiment used standard audiometric procedures to measure 8- and 16-kHz thresholds for 5- to 28-year olds with normal hearing in the standard audiometric range (250 to 8000 Hz). Stimuli were steady tones, pulsed tones, and FM tones. The second experiment tested 18- to 28-year olds with normal hearing in the standard audiometric range using psychophysical procedures to evaluate how changes in sensitivity as a function of frequency affect detection of stimuli that differ with respect to bandwidth, including bands of noise. Thresholds were measured using steady tones, pulsed tones, FM tones, narrow bands of noise, and one-third-octave bands of noise at a range of center frequencies in one ear. RESULTS: In experiment 1, thresholds improved with increasing age at 8 kHz and worsened with increasing age at 16 kHz. Thresholds for individual participants were relatively similar for steady, pulsed, and FM tones at 8 kHz. At 16 kHz, mean thresholds were approximately 5 dB lower for FM tones than for steady or pulsed tones. This stimulus effect did not differ as a function of age. Experiment 2 replicated this greater stimulus effect at 16 kHz than at 8 kHz and showed that the slope of the audibility curve accounted for these effects. CONCLUSIONS: Contrary to prior expectations, there was no evidence that the choice of stimulus type affected school-age children more than adults. For individual participants, audiometric thresholds at 16 kHz were as much as 20 dB lower for FM tones than for steady tones. Threshold differences across stimuli at 16 kHz were predicted by differences in audibility across frequency, which can vary markedly between listeners. These results highlight the importance of considering spectral width of the stimulus used to evaluate EHF thresholds.


Subject(s)
Audiometry , Hearing , Adult , Child , Humans , Adolescent , Auditory Threshold , Audiometry/methods , Noise , Hearing Tests
11.
Am J Otolaryngol ; 45(3): 104199, 2024.
Article in English | MEDLINE | ID: mdl-38183921

ABSTRACT

PURPOSE: The relationship between specific external ear anomalies (EEA) and hearing loss has been previously described. However, there is no literature regarding the appropriate evaluation of patients with EEA by audiology or otolaryngology. The objective of this study was to determine the incidence of audiologic or otolaryngologic evaluation of patients with EEA. MATERIALS AND METHODS: A retrospective review of charts was conducted following approval from the institutional review board at Boston Medical Center. Charts of patients younger than 18 years old with EEA, identified using International Classification of Diseases (ICD)-9 codes 380-380.99, 744, and 744.4 and ICD-10 codes H61.90-92, Q16.0-16.9, Q17.0-17.9, Q18.0-18.2, from January 2012 to January 2019 were reviewed. Primary variables included incidence of audiologic and otolaryngologic evaluation, newborn hearing screen and audiometry results, and completion of surgical intervention. Binary logistic regressions were conducted for each group for diagnostic, procedural, and demographic characteristics. RESULTS: A total of 723 patients were diagnosed with EEA from January 2012 to January 2019. Of these patients, 327 (45.2 %) were evaluated by audiology and 327 (45.2 %) were evaluated by otolaryngology. Of the 364 patients who obtained audiograms, 63 (17.3 %) demonstrated hearing loss. Surgical procedures were performed on 119 (16.5 %) patients, with the most common procedure being excision of the EEA (n = 79, 66.4 %). A total of 468 patients had a documented newborn hearing screen. Failure of newborn hearing screen and presence of microtia were associated with increased otolaryngologic and audiologic evaluation. CONCLUSIONS: A majority of patients with EEAs do not obtain audiologic or otolaryngologic evaluation.


Subject(s)
Ear, External , Humans , Retrospective Studies , Male , Female , Incidence , Child , Adolescent , Child, Preschool , Ear, External/abnormalities , Infant , Infant, Newborn , Hearing Loss/epidemiology , Hearing Loss/diagnosis , Audiometry/methods , Audiology , Neonatal Screening/methods
12.
J Laryngol Otol ; 138(1): 38-42, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36938822

ABSTRACT

OBJECTIVE: Patients with hearing loss and tinnitus face lengthy waits to be seen in the ENT clinic. SHOEBOX Audiometry is an iPad-based, audiometric screening tool. A virtual hearing loss and non-pulsatile tinnitus clinic involving an ENT specialist virtually assessing cases based on the SHOEBOX audiogram, a patient symptom questionnaire and the primary care referral letter were implemented. This service evaluation explored the outcomes of the virtual clinic in reducing the need for a face-to-face ENT appointment. METHOD: This was a retrospective service evaluation of the first six months of the virtual hearing loss and non-pulsatile tinnitus clinic. RESULTS: A total of 210 patients were included: 34.8 per cent (73) were discharged without requiring audiologist assessment or an ENT appointment, 51.9 per cent (109) required formal audiological assessment, 36.7 per cent (77) required imaging and only 13.8 per cent (29) required a face-to-face ENT appointment. CONCLUSION: A virtual hearing loss and non-pulsatile tinnitus clinic minimised the number of patients requiring a traditional face-to-face clinic appointment within ENT.


Subject(s)
Deafness , Hearing Loss , Tinnitus , Humans , Tinnitus/diagnosis , Retrospective Studies , Hearing Loss/complications , Hearing Loss/diagnosis , Audiometry/methods
13.
Eur Arch Otorhinolaryngol ; 281(5): 2333-2340, 2024 May.
Article in English | MEDLINE | ID: mdl-38070046

ABSTRACT

BACKGROUND: The objective-based methods for intraoperative monitoring have been suggested to assess the coupling and the outcomes of Vibrant Soundbridge (VSB). Although several techniques were proposed, they have not been widely adopted due to their complexity and invasiveness. PURPOSE: This study aimed to investigate the accuracy of a new coupling quality index using an intraoperative ABR threshold via AcoustiAP and its correlation with the perioperative measures. METHODS: This is a prospective study conducted at a tertiary center. The medical records were retrieved for all patients who underwent VSB implantation and had an intraoperative objective assessment for the coupling efficiency. AcoustiAP was used to evaluate the intraoperative ABR thresholds, which were assessed directly after the floating mass transducer (FMT) placement using acoustic CE-Chirp signals. The Vibrogram was used for the postoperative audiological evaluation. A new coupling quality index was calculated based on the intraoperative ABR thresholds. RESULTS: Ten patients were eligible for the present study. The ABR thresholds for good coupling ranged from 35 to 60 dBnHL. The loose coupling thresholds ranged considerably from 40 to 100 dBnHL. Overall, the median intraoperative ABR threshold at good coupling was 42.5 (40-60) dBnHL and 60 (40-100) dBnHL at loose coupling. The analysis showed that there was a significant change in the coupling quality index at the good and loose coupling points (24.3 ± 14 vs 38.8 ± 18.2, respectively, p < 0.001). At a cut-off value of 22.6 dB, the coupling quality index had a sensitivity of 70%  and specificity of 90% for discriminating good and loose coupling. CONCLUSION: This study provides evidence for the utility of intraoperative ABR measurements in predicting the coupling efficiency in patients with VSB. Our results showed that the coupling quality index had an acceptable accuracy in discriminating between good and poor coupling, which can help clinicians optimize the fitting process for individuals and may ultimately lead to improved patient outcomes.


Subject(s)
Ossicular Prosthesis , Humans , Prospective Studies , Audiometry
14.
Braz J Otorhinolaryngol ; 90(1): 101359, 2024.
Article in English | MEDLINE | ID: mdl-38070239

ABSTRACT

OBJECTIVES: To assess the hearing thresholds in acute otitis media, otitis media with effusion and chronic otitis media (non-suppurative, non-cholesteatomatous suppurative and cholesteatomatous) and to compare the hearing outcomes with non-diseased ears (in bilateral cases) or contralateral healthy ears (in unilateral cases), since hearing loss is the most frequent sequel of otitis media and there is no previous study comparing the audiometric thresholds among the different forms of otitis media. METHODS: Cross sectional, controlled study. We performed conventional audiometry (500-8000Hz) and tympanometry in patients with otitis media and healthy individuals (control group). Hearing loss was considered when the hearing thresholds were > 25 dBHL. RESULTS: Of the 112 patients diagnosed with otitis media (151 ears), 48 were men (42.86%) and 64 were women (57.14%). The average age was 42.72 years. Of those, 25 (22.32%) were diagnosed as AOM, 15 (13.39%) were diagnosed with OME and the remaining 72 (63.28%) were diagnosed with COM (non-suppurative COM, n=31; suppurative COM, n=18; cholesteatomatous COM, n=23). As compared with controls, all forms of otitis media had significantly higher bone-conduction thresholds (500-4000Hz). Conductive hearing loss was the most frequent type of hearing loss (58.94%). However, the number of patients with mixed hearing loss was also relevant (39.07%). We noted that the presence of sensorioneural component occurred more frequently in 1) Higher frequencies; and 2) In groups of otitis media that were more active or severe in the inflammatory/infective standpoint (AOM, suppurative COM and cholesteatomatous COM). CONCLUSION: All types of otitis media, even those with infrequent episodes of inflammation and otorrhea, had worse bone conduction thresholds as compared with nondiseased ears (p<0.01). We observed worse hearing outcomes in ears with recurrent episodes of otorrhea and in ears with AOM, especially in high frequencies.


Subject(s)
Deafness , Hearing Loss , Otitis Media with Effusion , Otitis Media , Male , Humans , Female , Adult , Cross-Sectional Studies , Otitis Media/complications , Audiometry , Acoustic Impedance Tests , Otitis Media with Effusion/diagnosis , Otitis Media with Effusion/etiology
15.
Behav Res Methods ; 56(3): 1433-1448, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37326771

ABSTRACT

Anonymous web-based experiments are increasingly used in many domains of behavioral research. However, online studies of auditory perception, especially of psychoacoustic phenomena pertaining to low-level sensory processing, are challenging because of limited available control of the acoustics, and the inability to perform audiometry to confirm normal-hearing status of participants. Here, we outline our approach to mitigate these challenges and validate our procedures by comparing web-based measurements to lab-based data on a range of classic psychoacoustic tasks. Individual tasks were created using jsPsych, an open-source JavaScript front-end library. Dynamic sequences of psychoacoustic tasks were implemented using Django, an open-source library for web applications, and combined with consent pages, questionnaires, and debriefing pages. Subjects were recruited via Prolific, a subject recruitment platform for web-based studies. Guided by a meta-analysis of lab-based data, we developed and validated a screening procedure to select participants for (putative) normal-hearing status based on their responses in a suprathreshold task and a survey. Headphone use was standardized by supplementing procedures from prior literature with a binaural hearing task. Individuals meeting all criteria were re-invited to complete a range of classic psychoacoustic tasks. For the re-invited participants, absolute thresholds were in excellent agreement with lab-based data for fundamental frequency discrimination, gap detection, and sensitivity to interaural time delay and level difference. Furthermore, word identification scores, consonant confusion patterns, and co-modulation masking release effect also matched lab-based studies. Our results suggest that web-based psychoacoustics is a viable complement to lab-based research. Source code for our infrastructure is provided.


Subject(s)
Auditory Perception , Hearing , Humans , Psychoacoustics , Hearing/physiology , Auditory Perception/physiology , Audiometry , Internet , Auditory Threshold/physiology , Acoustic Stimulation
16.
Int J Audiol ; 63(3): 221-225, 2024 Mar.
Article in English | MEDLINE | ID: mdl-36811451

ABSTRACT

OBJECTIVE: The clinical audiology test battery often involves playing physically simple sounds with questionable ecological value to the listener. In this technical report, we revisit how valid this approach is using an automated, involuntary auditory response; the acoustic reflex threshold (ART). DESIGN: The ART was estimated four times in each individual in a quasi-random ordering of task conditions. The baseline condition (referred to as Neutral) measured the ART following a standard clinical practice. Three experimental conditions were then used in which a secondary task was performed whilst the reflex was measured: auditory attention, auditory distraction and visual distraction tasks. STUDY SAMPLE: Thirty-eight participants (27 males) with a mean age of 23 years were tested. All participants were audiometrically healthy. RESULTS: The ART was elevated when a visual task was performed at the same time as the measurements were taken. Performing an auditory task did not affect the ART. CONCLUSIONS: These data indicate that simple audiometric measures widely used in the clinic, can be affected by central, non-auditory processes even in healthy, normal-hearing volunteers. The role of cognition and attention on auditory responses will become ever more important in the coming years.


Subject(s)
Hearing Tests , Reflex, Acoustic , Adult , Humans , Male , Young Adult , Acoustic Stimulation , Acoustics , Audiometry , Auditory Threshold/physiology , Reflex, Acoustic/physiology , Female
17.
HNO ; 72(1): 44-50, 2024 Jan.
Article in German | MEDLINE | ID: mdl-37615685

ABSTRACT

A 41-year-old female patient presented due to acute onset of unilateral hearing loss 3 months previously and persistent since then. Systemic therapy with oral glucocorticoids in decreasing doses had been performed beforehand, but did not lead to any improvement. In the course of audiological diagnostics, based on subjective and objective methods, a retrocochlear hearing disorder was suspected. A meningioma was diagnosed by diagnostic imaging. Subsequent surgical removal achieved a significant hearing improvement.


Subject(s)
Hearing Loss, Sensorineural , Hearing Loss, Sudden , Hearing Loss, Unilateral , Female , Humans , Adult , Hearing Disorders , Hearing , Hearing Tests , Hearing Loss, Sensorineural/diagnosis , Audiometry
18.
Ear Hear ; 45(2): 505-510, 2024.
Article in English | MEDLINE | ID: mdl-37759362

ABSTRACT

OBJECTIVES: Clinical practice guidelines predicate the need for evaluation of hearing in children with otitis media with effusion (OME). The objective of this work was to characterize the completeness of hearing assessment results in children with OME. DESIGN: Forty participants with OME completed two full audiological assessments, one in a clinical setting and a second in a research setting. An additional 14 participants without OME completed a single audiological assessment in the research setting as a control group. The success of various behavioral and objective audiometric tests in each setting was quantified and evaluated. RESULTS: Findings indicate that ear-specific behavioral audiometric information is substantially limited in children with OME, particularly in clinical settings. In contrast, objective testing including tympanometry and otoacoustic emission testing was largely successful. CONCLUSIONS: Ear-specific behavioral audiometric information is limited in children with OME and, consequently, consideration of these data for use as part of clinical decision making is also limited. Objective tests were more successful but are not direct measures of hearing.


Subject(s)
Otitis Media with Effusion , Otitis Media , Child , Humans , Otitis Media with Effusion/diagnosis , Audiometry , Acoustic Impedance Tests , Otoacoustic Emissions, Spontaneous
19.
Auris Nasus Larynx ; 51(2): 347-355, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37788966

ABSTRACT

OBJECTIVE: Asymmetric sensorineural hearing loss (ASHL) is the most common symptom of sporadic vestibular schwannoma (VS). However, there is still no universally accepted MRI protocol for diagnosing VS. This study identified the characteristics of pure tone audiogram (PTA) in patients with VS. METHODS: We conducted a retrospective chart review of patients diagnosed with sporadic unilateral VS. In the analysis, we focused on the shape and interaural differences of PTA, stratified by the mode of onset and patient age. RESULTS: In total, 390 patients met the inclusion criteria. The U-shaped audiogram showed the highest proportion in patients with the onset of sudden sensorineural hearing loss (SSNHL). In patients with SSNHL, U-shaped audiograms were younger than other audiograms, and 86.7 % of patients under 40 had U-shaped audiograms. Patients with VS were more likely to have interaural differences at higher frequencies than at lower frequencies. Patients with SSNHL had a significantly higher percentage of interaural differences at 500-4000 Hz than those with onset other than SSNHL (non-SSNHL patients). In addition, non-SSNHL patients had a significant trend toward a higher percentage of interaural differences at all frequencies with increasing age. CONCLUSION: MRI screening can be considered in patients with SSNHL with U-shaped audiograms under 40 years of age. In ASHL, not SSNHL, MRI screening can be considered for older patients with interaural differences at wider continuous frequencies. Patients with interaural differences at high frequencies had a higher priority than those with interaural differences at low frequencies as indications for MRI screening for VS.


Subject(s)
Hearing Loss, Sensorineural , Hearing Loss, Sudden , Neuroma, Acoustic , Humans , Neuroma, Acoustic/complications , Neuroma, Acoustic/diagnostic imaging , Retrospective Studies , Audiometry , Hearing Tests , Hearing Loss, Sensorineural/diagnosis , Caffeine , Audiometry, Pure-Tone
20.
HNO ; 72(Suppl 1): 56-62, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37812257

ABSTRACT

BACKGROUND: One of the main treatment goals in cochlear implant (CI) patients is to improve speech perception. One of the target parameters is speech intelligibility in quiet. However, treatment results show a high variability, which has not been sufficiently explained so far. The aim of this noninterventional retrospective study was to elucidate this variability using a selected population of patients in whom etiology was not expected to have a negative impact on postoperative speech intelligibility. MATERIALS AND METHODS: Audiometric findings of the CI follow-up of 28 adult patients after 6 months of CI experience were evaluated. These were related to the preoperative audiometric examination and evaluated with respect to a recently published predictive model for the postoperative monosyllabic score. RESULTS: Inclusion of postoperative categorical loudness scaling and hearing loss for Freiburg numbers in the model explained 55% of the variability in fitting outcomes with respect to monosyllabic word recognition. CONCLUSION: The results of this study suggest that much of the cause of variability in fitting outcomes can be captured by systematic postoperative audiometric checks. Immediate conclusions for CI system fitting adjustments may be drawn from these results. However, the extent to which these are accepted by individual patients and thus lead to an improvement in outcome must be subject of further studies, preferably prospective.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Adult , Humans , Retrospective Studies , Prospective Studies , Cochlear Implantation/methods , Audiometry
SELECTION OF CITATIONS
SEARCH DETAIL
...