Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
2.
Int J Cardiol ; 407: 132000, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38561108

ABSTRACT

AIM: To evaluate the association between raphe in bicuspid aortic valve (BAV) patients and valve dysfunction, aortopathy and aortic valve surgery in the REBECCA registry [REgistro della valvola aortica Bicuspide della Società Italiana di ECocardiografia e CArdiovascular Imaging (SIECVI)]. METHODS: Prevalence of aortic valve dysfunction and aortopathy was investigated in BAV patients with and without raphe. Aortic valve dysfunction (regurgitation or stenosis) was categorized as mild, moderate and severe. Aortopathy was defined as annulus ≥14 mm/m2; root ≥20 mm/m2; sinotubular junction ≥16 mm/m2; ascending aorta ≥17 mm/m2, and classified in Type A, isolated ascending aorta dilatation; Type B, aortic root and ascending aorta dilatation; and Type C, isolated aortic root dilatation. RESULTS: Overall, 695 patients with BAV were enrolled; 520 (74.8%) with raphe and 175 (25.2%) without raphe. BAV patients with raphe presented more frequently with moderate or severe aortic stenosis than BAV patients without raphe (183 [35.2%] vs 34 [19.4%], p < 0.001). A higher prevalence of aortopathy, particularly Type B, was observed in patients with vs without raphe. At multivariable analysis, raphe was a predictor of aortic valve surgery at three-year follow-up (odds ratio 2.19, 95% confidence interval 1.08-4.44, p < 0.001). CONCLUSIONS: Patients with BAV and raphe have a higher prevalence of significant aortic stenosis, aortopathy, especially Type B, and a higher risk of undergoing aortic valve surgery at three-year follow-up.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Registries , Humans , Male , Female , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/complications , Middle Aged , Aortic Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Heart Valve Diseases/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/complications , Aortic Diseases/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/epidemiology , Adult , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Follow-Up Studies , Italy/epidemiology
3.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Article in English | MEDLINE | ID: mdl-38577939

ABSTRACT

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Treatment Outcome , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Time Factors , Aged , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Aged, 80 and over , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Recovery of Function , Hemodynamics , Risk Assessment
5.
Cardiovasc Revasc Med ; 63: 16-20, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38233251

ABSTRACT

BACKGROUND: There continues to be debate regarding the superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) in patients with bicuspid aortic valves (BAV). We aimed to compare outcomes during readmissions in elderly patients with BAV who underwent SAVR or TAVR. METHODS: Patients 65 years or older with BAV who underwent TAVR or isolated SAVR were identified using the National Readmission Database from 2012 through 2018. We compared outcomes during readmissions within 90 days after discharge from the index surgery. Propensity score matching was performed to adjust the baseline differences. RESULTS: During the study period, 8555 and 1081 elderly patients with BAV underwent SAVR and TAVR, respectively. The number of patients who underwent TAVR went up by 179 % from 2012 to 2018. Propensity score matching yielded 573 patients in each group. A total of 111 (19.4 %) in the SAVR group and 125 (21.8 %) in the TAVR group were readmitted within 90 days after the index surgery (p = .31). The mortality during the readmissions within 90 days was equivalent between the two groups (0.9 % in the SAVR group vs. 3.2 % in the TAVR group, p = .22). However, the median hospital cost was approximately doubled in the TAVR group during the readmission (18,250 dollars vs. 9310 dollars in the SAVR group, p < .001). CONCLUSIONS: Readmission within 90 days was common in both groups. While the mortality during the readmissions after the surgery was equivalent between the two groups, hospital cost was significantly more expensive in the TAVR group.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Databases, Factual , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Patient Readmission , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/economics , Male , Female , Aged , Treatment Outcome , Time Factors , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/physiopathology , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Risk Factors , United States , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/economics , Retrospective Studies , Age Factors , Risk Assessment , Heart Valve Diseases/surgery , Heart Valve Diseases/mortality , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Postoperative Complications/etiology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology
6.
Ann Biomed Eng ; 51(12): 2802-2811, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37573264

ABSTRACT

In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4-dimensional (4D) flow magnetic resonance imaging (MRI) using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity ([Formula: see text]) in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the [Formula: see text] values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with non-AS TAV, non-AS BAV, non-AS MAV, and AS could be classified with ROC-AUC (area under the receiver operating characteristic curves) values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Deep Learning , Wearable Electronic Devices , Humans , Aortic Valve/diagnostic imaging , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Bicuspid Aortic Valve Disease/diagnostic imaging , Hemodynamics
7.
Ann Biomed Eng ; 50(1): 1-15, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34993699

ABSTRACT

The clinical benefit of patient-specific modeling of heart valve disease remains an unrealized goal, often a result of our limited understanding of the in vivo milieu. This is particularly true in assessing bicuspid aortic valve (BAV) disease, the most common cardiac congenital defect in humans, which leads to premature and severe aortic stenosis or insufficiency (AS/AI). However, assessment of BAV risk for AS/AI on a patient-specific basis is hampered by the substantial degree of anatomic and functional variations that remain largely unknown. The present study was undertaken to utilize a noninvasive computational pipeline ( https://doi.org/10.1002/cnm.3142 ) that directly yields local heart valve leaflet deformation information using patient-specific real-time three-dimensional echocardiographic imaging (rt-3DE) data. Imaging data was collected for patients with normal tricuspid aortic valve (TAV, [Formula: see text]) and those with BAV ([Formula: see text] with fused left and right coronary leaflets and [Formula: see text] with fused right and non-coronary leaflets), from which the medial surface of each leaflet was extracted. The resulting deformation analysis resulted in, for the first time, quantified differences between the in vivo functional deformations of the TAV and BAV leaflets. Our approach was able to capture the complex, heterogeneous surface deformation fields in both TAV and BAV leaflets. We were able to identify and quantify differences in stretch patterns between leaflet types, and found in particular that stretches experienced by BAV leaflets during closure differ from those of TAV leaflets in terms of both heterogeneity as well as overall magnitude. Deformation is a key parameter in the clinical assessment of valvular function, and serves as a direct means to determine regional variations in structure and function. This study is an essential step toward patient-specific assessment of BAV based on correlating leaflet deformation and AS/AI progression, as it provides a means for assessing patient-specific stretch patterns.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Aorta , Aortic Valve/diagnostic imaging , Bicuspid Aortic Valve Disease/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Humans , Tricuspid Valve
8.
Am J Cardiol ; 163: 85-90, 2022 01 15.
Article in English | MEDLINE | ID: mdl-34799086

ABSTRACT

Bicuspid aortic valve (BAV) is a common congenital heart disease, with a 10-fold higher prevalence in first-degree relatives. BAV has different phenotypes based on the morphology of cusp fusion. These phenotypes are associated with different clinical courses and prognoses. Currently, the determinants of the valve phenotype are unknown. In this study we evaluated the role of genetics using familial cohorts. Patients with BAV and their first-degree relatives were evaluated by echocardiography. The concordance in BAV phenotype between pairs of family members was calculated and compared with the concordance expected by chance. We then performed a systematic literature review to identify additional reports and calculated the overall concordance rate. During the study period, 70 cases from 31 families and 327 sporadic cases were identified. BAV was diagnosed in 14% of the screened relatives. The proportions of the morphologies identified was: 12.3% for type 0, 66.2% for type 1-LR, 15.4% for type 1-RN, 4.6% for type 1-NL, and 1.5% for type 2. For the assessment of morphologic concordance, we included 120 pairs of first-degree relatives with BAV from our original cohort and the literature review. Concordance was found only in 62% of the pairs which was not significantly higher than expected by chance. In conclusion, our finding demonstrates intrafamilial variability in BAV morphology, suggesting that morphology is determined by factors other than Mendelian genetics. As prognosis differs by morphology, our findings may suggest that clinical outcomes may vary even between first-degree relatives.


Subject(s)
Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/genetics , Adult , Aged , Bicuspid Aortic Valve Disease/classification , Echocardiography , Family , Female , Humans , Male , Mass Screening , Middle Aged , Phenotype
9.
BMC Cardiovasc Disord ; 21(1): 590, 2021 12 07.
Article in English | MEDLINE | ID: mdl-34876008

ABSTRACT

BACKGROUND: Optimal projection is essential for valve deployment during transcatheter aortic valve implantation (TAVI). The purpose of this study was to propose an approach to predict optimal projection in TAVI candidates with different aortic valve anatomies. METHODS: 331 patients undergoing self-expanding TAVI were included and the so-called non-coronary cusp (NCC)-parallel technique was utilized, which generated the predicted projection by connecting NCC commissures on the transverse plane on the pre-procedural computed tomography images. RESULTS: 37.8% of the study cohort were bicuspid aortic valve (BAV) patients. Around 80% of both NCC-parallel views and final views were in the right anterior oblique (RAO) and caudal (CAU) quadrant. There was less than 5° change required from the NCC-parallel view to the final implanted view in 79% of tricuspid aortic valve (TAV) patients but only in 27% (13/48) of type 0 BAV patients with coronary arteries originated from the different cusps. After excluding the above mentioned BAV patients, 62.3% (48/77) of BAV patients needed less than 5° change to achieve optimal projection and only in 8 patients, the angular change was larger than 10° in either left/right anterior oblique or cranial/caudal direction. CONCLUSIONS: The NCC-parallel technique provides reliable prediction for optimal projection in self-expanding TAVI in all TAV and most BAV patients, with a vast majority of views in the RAO and CAU quadrant.


Subject(s)
Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/surgery , Multidetector Computed Tomography , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Anatomic Landmarks , Aortic Valve/abnormalities , Clinical Decision-Making , Female , Heart Valve Prosthesis , Humans , Male , Predictive Value of Tests , Prospective Studies , Prosthesis Design
10.
J Pediatr ; 239: 219-224, 2021 12.
Article in English | MEDLINE | ID: mdl-34400210

ABSTRACT

OBJECTIVE: To determine uptake of cardiac screening and recurrence of bicuspid aortic valve (BAV) and thoracic aortic aneurysm (TAA) in a population of at-risk siblings of pediatric probands. STUDY DESIGN: A retrospective chart review of pediatric patients with known BAV and/or TAA was performed. Echocardiogram data from identified siblings were collected to determine screening uptake and recurrence of BAV and TAA. Statistical analyses were performed using Wilcoxon signed-rank test and chi-square. RESULTS: The cohort included 251 probands and 388 at-risk siblings. Among the siblings, 150 had at least 1 echocardiogram, giving an overall screening uptake of 38.7%. The only factor found to be associated with increased uptake was documented recommendation for screening of first-degree relatives in the proband's initial cardiology note (P = .03). A total of 11 screened siblings (7.3%) had BAV and 19 had TAA (12.7%), with an overall combined recurrence of 15.3%. Siblings of probands who had both BAV and TAA had increased recurrence of TAA compared with siblings of probands with isolated BAV (16.1% vs 3.9%, respectively). CONCLUSIONS: Given low uptake in at-risk siblings, the opportunity exists to assess barriers for families in pursuing the recommended screening. Furthermore, the relatively high recurrence of BAV and TAA in at-risk siblings highlights the potential for improved health outcomes through increased screening and early detection. Developing standardized guidelines and promoting early cardiac screening in at-risk siblings while counseling families about hereditary risk for BAV and TAA may help improve uptake and optimize clinical management in at-risk pediatric patients.


Subject(s)
Aortic Aneurysm, Thoracic/diagnostic imaging , Bicuspid Aortic Valve Disease/diagnostic imaging , Echocardiography/statistics & numerical data , Patient Acceptance of Health Care/statistics & numerical data , Siblings , Adolescent , Aortic Aneurysm, Thoracic/complications , Bicuspid Aortic Valve Disease/complications , Child , Child, Preschool , Early Diagnosis , Female , Humans , Infant , Infant, Newborn , Male , Recurrence , Retrospective Studies , Risk
11.
J Am Heart Assoc ; 10(17): e020785, 2021 09 07.
Article in English | MEDLINE | ID: mdl-34459236

ABSTRACT

Background Bicuspid aortic valve (BAV) is the most common congenital heart disease in adults but is clinically heterogeneous. We aimed to describe the echocardiographic characteristics of BAV and compare patients with BAV with moderate-to-severe aortic stenosis (AS) with those with tricuspid aortic valve (TAV) stenosis. Methods and Results Using the National Echo Database of Australia, patients in whom BAV was identified were studied. Those with moderate-to-severe AS (mean gradient >20 mm Hg [BAV-AS]) were compared with those with TAV and moderate-to-severe AS (TAV-AS). Of 264 159 adults whose aortic valve morphology was specified, 4783 (1.8%) had confirmed BAV (aged 49.6±17.4 years, 69% men). Of these, 42% had no AS, and 46% had no aortic regurgitation. Moderate-to-severe AS was detected in a greater proportion of patients with BAV with a recorded mean gradient (n=1112, 34%) compared with those with TAV (n=4377, 4%; P<0.001). Patients with BAV-AS were younger (aged 55.3±16.7 years versus 77.3±11.0 years; P<0.001), and where measured had larger ascending aortic diameters (37±8 mm versus 35±5 mm; P<0.001). Age and sex-adjusted mortality risk was significantly lower in patients with BAV-AS (hazard ratio, 0.53; 95% CI, 0.45-0.63; P<0.001). Conclusions In this large study of patients across the spectrum of BAV disease, the largest proportion had no significant valvulopathy or aortopathy. Compared with those with TAV-AS, patients with BAV were more likely to have moderate-to-severe AS, have larger ascending aortas, and were over 2 decades younger at the time of AS diagnosis. Despite this, patients with BAV appear to have a more favorable prognosis when AS develops, compared with those with TAV-AS. Registration URL: www.anzctr.org.au/; Unique identifier: ACTRN12617001387314.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Mitral Valve Stenosis , Adult , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/epidemiology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/epidemiology , Constriction, Pathologic , Female , Humans , Male , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/epidemiology
12.
BMC Cardiovasc Disord ; 21(1): 377, 2021 08 04.
Article in English | MEDLINE | ID: mdl-34348659

ABSTRACT

BACKGROUND: Patients with both double orifice mitral valve (DOMV) and bicuspid aortic valve (BAV) malformation are rare. Although DOMV or BAV can be detected in some genetic syndromes, it has not been reported to simultaneously appear in Turner syndrome (TS). TrueVue, TouchVue, and TrueVue Glass are the latest technologies in advanced three-dimensional echocardiography (3DE), which is an important information supplement to two-dimensional echocardiography (2DE) for the diagnosis of congenital cardiac malformations. Herein we report the novel use of the above-mentioned technologies in the diagnosis and evaluation of a rare, combined valve malformation. Meanwhile, we also reviewed the literature for cases involving both DOMV and BAV and their association with various genetic syndromes. CASE PRESENTATION: We present the case of a 5-year-old girl diagnosed with TS because of a developmental delay. DOMV and BAV were found through echocardiographic examination. Three-dimensional transthoracic echocardiography as well as a series of novel advanced techniques were applied to clearly display the spatial structure of all tiers of the mitral valve apparatus, aortic valve, and arch to facilitate an accurate diagnosis. CONCLUSIONS: This is the first case in which both DOMV and BAV were associated with TS. Innovative TrueVue and TrueVue Glass offer unprecedented photographic stereoscopic images, while TouchVue technology greatly improved the ultrasonic diagnostic workflow and the diagnostic performance of rare valve malformations by adding virtual light sources to display realistic light-shadow effects.


Subject(s)
Bicuspid Aortic Valve Disease/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Mitral Valve/abnormalities , Mitral Valve/diagnostic imaging , Turner Syndrome/complications , Child, Preschool , Female , Humans , Papillary Muscles/diagnostic imaging , Rare Diseases/diagnostic imaging
13.
BMC Cardiovasc Disord ; 21(1): 413, 2021 08 30.
Article in English | MEDLINE | ID: mdl-34461831

ABSTRACT

BACKGROUND: The bicuspid aortic valve (BAV) is prone to ascending aortic dilatation (AAD) involving both the tubular segment and the aortic root. The genetic factor was proposed as one of the most important mechanisms for AAD. We hypothesized that the rare genetic variants mainly contribute to the pathogenesis of aortic roots in affected individuals. METHODS: The diameter of aortic root or ascending aorta ≥ 40 mm was counted as AAD. The targeted next-generation sequencing of 13 BAV-associated genes were performed on a continuous cohort of 96 unrelated BAV patients. The rare variants with allele frequency < 0.05% were selected and analyzed. Variants frequency was compared against the Exome aggregation consortium database. The pathogenicity of the genetic variants was evaluated according to the American College of Medical Genetics and Genomics guidelines. RESULTS: A total of 27 rare nonsynonymous coding variants involving 9 genes were identified in 25 individuals. The burden analysis revealed that variants in GATA5, GATA6, and NOTCH1 were significantly associated with BAV. Eighty percent of the pathogenic variants were detected in root group. The detection rate of rare variants was higher in root dilatation group (71.4%) compared with normal aorta (29.0%) and tubular dilatation groups (29.6%) (P = 0.018). The rare variant was identified as the independent risk factor of root dilatation [P = 0.014, hazard ratio = 23.9, 95% confidence interval (1.9-302.9)]. CONCLUSIONS: Our results presented a broad genetic spectrum in BAV patients. The rare variants of BAV genes contribute the most to the root phenotype among BAV patients.


Subject(s)
Aortic Aneurysm/genetics , Bicuspid Aortic Valve Disease/genetics , Genetic Variation , Adolescent , Adult , Aged , Aortic Aneurysm/diagnostic imaging , Bicuspid Aortic Valve Disease/complications , Bicuspid Aortic Valve Disease/diagnostic imaging , Female , Gene Frequency , Genetic Association Studies , Genetic Predisposition to Disease , Heredity , High-Throughput Nucleotide Sequencing , Humans , Male , Middle Aged , Phenotype , Risk Assessment , Risk Factors , Young Adult
14.
J Thorac Cardiovasc Surg ; 162(3): 781-797, 2021 09.
Article in English | MEDLINE | ID: mdl-34304894

ABSTRACT

This International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type, with 3 phenotypes: right-left cusp fusion, right-non cusp fusion and left-non cusp fusion; 2. 2-sinus type with 2 phenotypes: Latero-lateral and antero-posterior; and 3. Partial-fusion or forme fruste. This consensus recognizes 3 bicuspid-aortopathy types: 1. Ascending phenotype; root phenotype; and 3. extended phenotypes.


Subject(s)
Aorta , Aortic Diseases/classification , Aortic Valve/abnormalities , Bicuspid Aortic Valve Disease/classification , Terminology as Topic , Aorta/diagnostic imaging , Aorta/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortography , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/surgery , Cardiac Imaging Techniques , Consensus , Humans , Phenotype , Predictive Value of Tests , Prognosis
15.
J Thorac Cardiovasc Surg ; 162(3): e383-e414, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34304896

ABSTRACT

This International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion, right-non-coronary cusp fusion and left-non-coronary cusp fusion phenotypes); 2. The 2-sinus type (latero-lateral and antero-posterior phenotypes); and 3. The partial-fusion (forme fruste) type. The presence of raphe and the symmetry of the fused type phenotypes are critical aspects to describe. The International Consensus also recognizes 3 types of bicuspid valve-associated aortopathy: 1. The ascending phenotype; 2. The root phenotype; and 3. Extended phenotypes.


Subject(s)
Aorta , Aortic Diseases/classification , Aortic Valve/abnormalities , Bicuspid Aortic Valve Disease/classification , Terminology as Topic , Aorta/diagnostic imaging , Aorta/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortography , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/surgery , Cardiac Imaging Techniques , Consensus , Humans , Phenotype , Predictive Value of Tests , Prognosis
16.
J Am Heart Assoc ; 10(12): e020080, 2021 06 15.
Article in English | MEDLINE | ID: mdl-34075785

ABSTRACT

Background Bicuspid aortic valve (BAV) is the most common congenital cardiac malformation, which is often complicated by aortic valve stenosis (AoS). In tricuspid aortic valve (TAV), AoS strongly associates with coronary artery disease (CAD) with common pathophysiological factors. Yet, it remains unclear whether AoS in patients with BAV is also associated with CAD. This study investigated the association between the aortic valve morphological features and the extent of CAD. Methods and Results A single-center study was performed, including all patients who underwent an aortic valve replacement attributable to AoS between 2006 and 2019. Coronary sclerosis was graded on preoperative coronary angiographies using the coronary artery greater even than scoring method, which divides the coronaries in 28 segments and scores nonobstructive (20%-49% sclerosis) and obstructive coronary sclerosis (>49% sclerosis) in each segment. Multivariate analyses were performed, controlling for age, sex, and CAD risk factors. A total of 1296 patients (931 TAV and 365 BAV) were included, resulting in 548 matched patients. Patients with TAV exhibited more CAD risk factors (odds ratio [OR], 2.66; 95% CI, 1.79-3.96; P<0.001). Patients with BAV had lower coronary artery greater even than 20 (1.61±2.35 versus 3.60±2.79) and coronary artery greater even than 50 (1.24±2.43 versus 3.37±3.49) scores (P<0.001), even after correcting for CAD risk factors (P<0.001). Patients with TAV more often needed concomitant coronary revascularization (OR, 3.50; 95% CI, 2.42-5.06; P<0.001). Conclusions Patients with BAV who are undergoing surgery for AoS carry a lower cardiovascular risk profile, correlating with less coronary sclerosis and a lower incidence of concomitant coronary revascularization compared with patients with TAV.


Subject(s)
Aortic Valve Stenosis/epidemiology , Bicuspid Aortic Valve Disease/epidemiology , Coronary Artery Disease/epidemiology , Aged , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/surgery , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Female , Heart Valve Prosthesis Implantation , Humans , Male , Middle Aged , Netherlands , Prevalence , Retrospective Studies , Severity of Illness Index , Treatment Outcome
17.
Ann Biomed Eng ; 49(9): 2441-2453, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34080100

ABSTRACT

Motivated by the evidence that the onset and progression of the aneurysm of the ascending aorta (AAo) is intertwined with an adverse hemodynamic environment, the present study characterized in vivo the hemodynamic spatiotemporal complexity and organization in human aortas, with and without dilated AAo, exploring the relations with clinically relevant hemodynamic and geometric parameters. The Complex Networks (CNs) theory was applied for the first time to 4D flow magnetic resonance imaging (MRI) velocity data of ten patients, five of them presenting with AAo dilation. The time-histories along the cardiac cycle of velocity-based quantities were used to build correlation-based CNs. The CNs approach succeeded in capturing large-scale coherent flow features, delimiting flow separation and recirculation regions. CNs metrics highlighted that an increasing AAo dilation (expressed in terms of the ratio between the maximum AAo and aortic root diameter) disrupts the correlation in forward flow reducing the correlation persistence length, while preserving the spatiotemporal homogeneity of secondary flows. The application of CNs to in vivo 4D MRI data holds promise for a mechanistic understanding of the spatiotemporal complexity and organization of aortic flows, opening possibilities for the integration of in vivo quantitative hemodynamic information into risk stratification and classification criteria.


Subject(s)
Aorta , Aortic Aneurysm , Bicuspid Aortic Valve Disease , Magnetic Resonance Imaging/methods , Models, Cardiovascular , Aorta/diagnostic imaging , Aorta/physiology , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/physiopathology , Coronary Circulation , Hemodynamics , Humans
18.
Pediatr Cardiol ; 42(5): 1133-1140, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33864103

ABSTRACT

Patients with bicuspid aortic valve (BAV) have an increased risk of aortic dilation and aortic dissection or rupture. The impact of physical training on the natural course of aortopathy in BAV patients remains unclear. The aim of this study was to evaluate the impact of regular physical activity on aortic diameters in a consecutive cohort of paediatric patients with BAV. Consecutive paediatric BAV patients were evaluated and categorized into two groups: physically active and sedentary subjects. Only the subjects with a complete 2-year follow-up were included in the study. To evaluate the potential impact of physical activity on aortic size, aortic diameters were measured at the sinus of Valsalva and mid-ascending aorta using echocardiography. We defined aortic diameter progression the increase of aortic diameter ≥ 10% from baseline. Among 90 BAV patients (11.5 ± 3.4 years of age, 77% males), 53 (59%) were physically active subjects. Compared to sedentary, physically active subjects were not significantly more likely to have > 10% increase in sinus of Valsalva (13% vs. 8%, p-value = 0.45) or mid-ascending aorta diameter (9% vs. 13%, p-value = 0.55) at 2 years follow-up, both in subjects with sinus of Valsalva diameter progression (3.7 ± 1.0 mm vs. 3.5 ± 0.8 mm, p-value = 0.67) and in those with ascending aorta diameter progression (3.0 ± 0.8 mm vs. 3.2 ± 1.3 mm, p-value = 0.83). In our paediatric cohort of BAV patients, the prevalence and the degree of aortic diameter progression was not significantly different between physically active and sedentary subjects, suggesting that aortic dilation is unrelated to regular physical activity over a 2-year period.


Subject(s)
Aortic Valve/pathology , Bicuspid Aortic Valve Disease/physiopathology , Disease Progression , Exercise , Adolescent , Aortic Valve/diagnostic imaging , Bicuspid Aortic Valve Disease/diagnostic imaging , Case-Control Studies , Child , Echocardiography , Female , Humans , Male , Retrospective Studies
19.
BMC Cardiovasc Disord ; 21(1): 153, 2021 03 25.
Article in English | MEDLINE | ID: mdl-33765934

ABSTRACT

BACKGROUND: We report a rare case of a patient who presented with chest pain and was found to have a constellation of rare cardiac anomalies. CASE PRESENTATION: A 67-year-old patient with no past medical history presented with chest pain. He had mild troponin elevation, but no ischemic changes on ECG. He underwent a CT coronary angiogram for further evaluation. He was found to have a type 0 bicuspid aortic valve, large left sinus of Valsalva aneurysm and type R-III single coronary artery. These findings were confirmed with transesophageal echocardiogram and coronary angiogram. He underwent a successful repair of his aortic root aneurysm with a synthetic patch. CONCLUSIONS: The combination of type R-III single coronary artery, bicuspid aortic valve, and left sinus of Valsalva aneurysm congenital anomalies in one individual is extremely rare and marks our case unique. Given the size of his Sinus of Valsalva aneurysm, the patient underwent surgical repair of his aneurysm and was asymptomatic when seen in follow-up.


Subject(s)
Aortic Aneurysm/complications , Bicuspid Aortic Valve Disease/complications , Coronary Vessel Anomalies/complications , Sinus of Valsalva , Aged , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Coronary Vessel Anomalies/diagnostic imaging , Humans , Male , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/surgery , Treatment Outcome
20.
J Cardiovasc Magn Reson ; 23(1): 9, 2021 02 15.
Article in English | MEDLINE | ID: mdl-33588887

ABSTRACT

BACKGROUND: Helices and vortices in thoracic aortic blood flow measured with 4D flow cardiovascular magnetic resonance (CMR) have been associated with aortic dilation and aneurysms. Current approaches are semi-quantitative or when fully quantitative based on 2D plane placement. In this study, we present a fully quantitative and three-dimensional approach to map and quantify abnormal velocity and wall shear stress (WSS) at peak systole in patients with a bicuspid aortic valve (BAV) of which 52% had a repaired coarctation. METHODS: 4D flow CMR was performed in 48 patients with BAV and in 25 healthy subjects at a spatiotemporal resolution of 2.5 × 2.5 × 2.5mm3/ ~ 42 ms and TE/TR/FA of 2.1 ms/3.4 ms/8° with k-t Principal Component Analysis factor R = 8. A 3D average of velocity and WSS direction was created for the normal subjects. Comparing BAV patient data with the 3D average map and selecting voxels deviating between 60° and 120° and > 120° yielded 3D maps and volume (in cm3) and surface (in cm2) quantification of abnormally directed velocity and WSS, respectively. Linear regression with Bonferroni corrected significance of P < 0.0125 was used to compare abnormally directed velocity volume and WSS surface in the ascending aorta with qualitative helicity and vorticity scores, with local normalized helicity (LNH) and quantitative vorticity and with patient characteristics. RESULTS: The velocity volumes > 120° correlated moderately with the vorticity scores (R ~ 0.50, P < 0.001 for both observers). For WSS surface these results were similar. The velocity volumes between 60° and 120° correlated moderately with LNH (R = 0.66) but the velocity volumes > 120° did not correlate with quantitative vorticity. For abnormal velocity and WSS deviating between 60° and 120°, moderate correlations were found with aortic diameters (R = 0.50-0.70). For abnormal velocity and WSS deviating > 120°, additional moderate correlations were found with age and with peak velocity (stenosis severity) and a weak correlation with gender. Ensemble maps showed that more than 60% of the patients had abnormally directed velocity and WSS. Additionally, abnormally directed velocity and WSS was higher in the proximal descending aorta in the patients with repaired coarctation than in the patients where coarctation was never present. CONCLUSION: The possibility to reveal directional abnormalities of velocity and WSS in 3D provides a new tool for hemodynamic characterization in BAV disease.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Aortic Coarctation/diagnostic imaging , Bicuspid Aortic Valve Disease/diagnostic imaging , Magnetic Resonance Angiography , Perfusion Imaging , Adult , Aorta, Thoracic/physiopathology , Aortic Coarctation/physiopathology , Aortic Coarctation/surgery , Bicuspid Aortic Valve Disease/physiopathology , Blood Flow Velocity , Case-Control Studies , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Regional Blood Flow , Stress, Mechanical , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...