Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 14.600
Filter
1.
Invest Ophthalmol Vis Sci ; 65(6): 9, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38837167

ABSTRACT

Purpose: Optical coherence tomography (OCT) representations in clinical practice are static and do not allow for a dynamic visualization and quantification of blood flow. This study aims to present a method to analyze retinal blood flow dynamics using time-resolved structural OCT. Methods: We developed novel imaging protocols to acquire video-rate time-resolved OCT B-scans (1024 × 496 pixels, 10 degrees field of view) at four different sensor integration times (integration time of 44.8 µs at a nominal A-scan rate of 20 kHz, 22.4 µs at 40 kHz, 11.2 µs at 85 kHz, and 7.24 µs at 125 kHz). The vessel centers were manually annotated for each B-scan and surrounding subvolumes were extracted. We used a velocity model based on signal-to-noise ratio (SNR) drops due to fringe washout to calculate blood flow velocity profiles in vessels within five optic disc diameters of the optic disc rim. Results: Time-resolved dynamic structural OCT revealed pulsatile SNR changes in the analyzed vessels and allowed the calculation of potential blood flow velocities at all integration times. Fringe washout was stronger in acquisitions with longer integration times; however, the ratio of the average SNR to the peak SNR inside the vessel was similar across all integration times. Conclusions: We demonstrated the feasibility of estimating blood flow profiles based on fringe washout analysis, showing pulsatile dynamics in vessels close to the optic nerve head using structural OCT. Time-resolved dynamic OCT has the potential to uncover valuable blood flow information in clinical settings.


Subject(s)
Regional Blood Flow , Retinal Vessels , Tomography, Optical Coherence , Tomography, Optical Coherence/methods , Humans , Retinal Vessels/physiology , Retinal Vessels/diagnostic imaging , Blood Flow Velocity/physiology , Regional Blood Flow/physiology , Optic Disk/blood supply , Optic Disk/diagnostic imaging , Signal-To-Noise Ratio , Male , Female , Adult , Middle Aged
2.
Langenbecks Arch Surg ; 409(1): 147, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38695955

ABSTRACT

PURPOSE: To investigate the accuracy of laser speckle flowgraphy (LSFG), a noninvasive method for the quantitative evaluation of blood flow using mean blur rate (MBR) as a blood flow parameter in the assessment of bowel blood perfusion compared to indocyanine green fluorescence angiography (ICG-FA). METHODS: We enrolled 46 patients who underwent left-sided colorectal surgery. LSFG and ICG-FA were applied to assess blood bowel perfusion, with MBR and luminance as parameters, respectively. In both measurement methods, the position where the parameter suddenly decreased was defined as the blood flow boundary line. Subsequently, the blood flow boundaries created after processing the blood vessels flowing into the intestinal tract were determined using LSFG and ICG-FA, and concordance between the two was examined. Blood flow boundaries were visually identified using color tone changes on a color map created based on MBR in LSFG and using differences in luminance in ICG-FA. The distances between the transection line and blood flow boundaries determined using each method were compared. RESULTS: The location of blood flow boundaries matched in 65% (30/46) of cases. Although locations differed in the remaining 35% (16/46), all were located on the anal side near the transection line, and the difference was not clinically significant. The average distances between the transection line and blood flow boundary were 2.76 (SD = 3.25) and 3.71 (SD = 4.26) mm, respectively. There was no statistically significant difference between the two groups (p = 0.38). CONCLUSION: LSFG was shown to have comparable accuracy to ICG-FA, and may be useful for evaluating bowel perfusion.


Subject(s)
Coloring Agents , Fluorescein Angiography , Indocyanine Green , Humans , Female , Fluorescein Angiography/methods , Male , Aged , Middle Aged , Laser Speckle Contrast Imaging , Aged, 80 and over , Regional Blood Flow/physiology , Adult , Intestines/blood supply , Blood Flow Velocity/physiology , Colorectal Neoplasms/surgery
3.
J Acoust Soc Am ; 155(5): 2948-2958, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38717204

ABSTRACT

Arteriosclerosis is a major risk factor for cardiovascular disease and results in arterial vessel stiffening. Velocity estimation of the pulse wave sent by the heart and propagating into the arteries is a widely accepted biomarker. This symmetrical pulse wave propagates at a speed which is related to the Young's modulus through the Moens Korteweg (MK) equation. Recently, an antisymmetric flexural wave has been observed in vivo. Unlike the symmetrical wave, it is highly dispersive. This property offers promising applications for monitoring arterial stiffness and early detection of atheromatous plaque. However, as far as it is known, no equivalent of the MK equation exists for flexural pulse waves. To bridge this gap, a beam based theory was developed, and approximate analytical solutions were reached. An experiment in soft polymer artery phantoms was built to observe the dispersion of flexural waves. A good agreement was found between the analytical expression derived from beam theory and experiments. Moreover, numerical simulations validated wave speed dependence on the elastic and geometric parameters at low frequencies. Clinical applications, such as arterial age estimation and arterial pressure measurement, are foreseen.


Subject(s)
Models, Cardiovascular , Phantoms, Imaging , Pulse Wave Analysis , Vascular Stiffness , Pulse Wave Analysis/methods , Humans , Elastic Modulus , Computer Simulation , Arteries/physiology , Arteries/physiopathology , Numerical Analysis, Computer-Assisted , Blood Flow Velocity/physiology
4.
Echocardiography ; 41(5): e15821, 2024 May.
Article in English | MEDLINE | ID: mdl-38706373

ABSTRACT

INTRODUCTION: Doppler-derived pulmonary pulse transit time (pPTT) is an auspicious hemodynamic marker in chronic pulmonary diseases. The aim is to compare four distinct pPTT measurements and its relation to right cardiac and pulmonary function. METHODS: Prospectively, 25 chronic obstructive pulmonary disease (COPD) patients (four patients excluded) and 32 healthy subjects underwent repeated distinct pPTT measurements, standard echocardiography, and pulmonary function testing on the same day. pPTT was defined as the interval from the R or Q-wave in the electrocardiogram to the corresponding pulse wave Doppler peak late systolic (S) 2 or diastolic (D) pulmonary vein flow velocity (pPTT R-S, Q-S, R-D, Q-D). Reproducibility was assessed using Bland-Altman analysis, coefficient of variation (COV), intraclass correlation coefficient (ICC), and power calculations. Associations with right ventricular RV tissue and pulse wave Doppler velocities (RV E', RV S', RV A', RV E, RV A, RV E/E', RV E/A), TAPSE, right ventricular fractional area change, left ventricular systolic and diastolic function (LV ejection fraction, E, A, E/A, E/E', septal E', lateral E'), LA diameters, as well as forced expiratory volume in 1 s, forced vital capacity (FVC) predicted (%), and in liters were analyzed. RESULTS: There was no significant difference and no bias between pPTT measures (p range: .1-.9). COV was in COPD 1.2%-2.3%, in healthy subjects 1.0%-3.1%. ICC ranged from .92 (COPD) to .96 (healthy subjects). In COPD significant correlations were found for pPTT R-S, Q-S and R-D with RV E`, (all > ρ: .49, < p = .0364), pPTT R-S, Q-S with RV E/E` (both > ρ: .49, < p = .0291), pPTT Q-S with RV S´ (ρ: .58, p = .0134), RV A (ρ: .59, p = .0339) and heart rate > ρ: -.39, < p = .0297). pPTT R-S, R-D showed significant correlations with FVC predicted (%) (ρ: .48 p = .0224) and FVC (l) (ρ:.47 p = .0347). CONCLUSIONS: All pPTT measures exhibited high reproducibility. In COPD patients pPTT measures correlate with diastolic right ventricular function. Defining Q as starting point seems clinically advantageous considering electromechanical desynchrony in patients with conduction disorders.


Subject(s)
Echocardiography, Doppler , Pulmonary Disease, Chronic Obstructive , Pulse Wave Analysis , Humans , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Male , Female , Reproducibility of Results , Pulse Wave Analysis/methods , Prospective Studies , Echocardiography, Doppler/methods , Aged , Middle Aged , Respiratory Function Tests/methods , Blood Flow Velocity/physiology
5.
Nature ; 629(8013): 810-818, 2024 May.
Article in English | MEDLINE | ID: mdl-38778234

ABSTRACT

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Subject(s)
Blood Flow Velocity , Brain , Cerebrovascular Circulation , Ultrasonography , Humans , Blood Flow Velocity/physiology , Brain/blood supply , Brain/diagnostic imaging , Brain/physiology , Cerebrovascular Circulation/physiology , Imaging, Three-Dimensional/instrumentation , Imaging, Three-Dimensional/methods , Medical Errors , Signal-To-Noise Ratio , Skin , Skull , Sleepiness/physiology , Ultrasonography/instrumentation , Ultrasonography/methods , Adult
6.
J Biomech ; 168: 112124, 2024 May.
Article in English | MEDLINE | ID: mdl-38701696

ABSTRACT

Congenital arterial stenosis such as supravalvar aortic stenosis (SVAS) are highly prevalent in Williams syndrome (WS) and other arteriopathies pose a substantial health risk. Conventional tools for severity assessment, including clinical findings and pressure gradient estimations, often fall short due to their susceptibility to transient physiological changes and disease stage influences. Moreover, in the pediatric population, the severity of these and other congenital heart defects (CHDs) often restricts the applicability of invasive techniques for obtaining crucial physiological data. Conversely, evaluating CHDs and their progression requires a comprehensive understanding of intracardiac blood flow. Current imaging modalities, such as blood speckle imaging (BSI) and four-dimensional magnetic resonance imaging (4D MRI) face limitations in resolving flow data, especially in cases of elevated flow velocities. To address these challenges, we devised a computational framework employing zero-dimensional (0D) lumped parameter models coupled with patient-specific reconstructed geometries pre- and post-surgical intervention to execute computational fluid dynamic (CFD) simulations. This framework facilitates the analysis and visualization of intricate blood flow patterns, offering insights into geometry and flow dynamics alterations impacting cardiac function. In this study, we aim to assess the efficacy of surgical intervention in correcting an extreme aortic defect in a patient with WS, leading to reductions in wall shear stress (WSS), maximum velocity magnitude, pressure drop, and ultimately a decrease in cardiac workload.


Subject(s)
Hemodynamics , Models, Cardiovascular , Williams Syndrome , Humans , Williams Syndrome/physiopathology , Williams Syndrome/diagnostic imaging , Hemodynamics/physiology , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnostic imaging , Aorta/physiopathology , Aorta/diagnostic imaging , Blood Flow Velocity/physiology , Male , Female , Computer Simulation
7.
J Physiol ; 602(10): 2227-2251, 2024 May.
Article in English | MEDLINE | ID: mdl-38690610

ABSTRACT

Passive whole-body hyperthermia increases limb blood flow and cardiac output ( Q ̇ $\dot Q$ ), but the interplay between peripheral and central thermo-haemodynamic mechanisms remains unclear. Here we tested the hypothesis that local hyperthermia-induced alterations in peripheral blood flow and blood kinetic energy modulate flow to the heart and Q ̇ $\dot Q$ . Body temperatures, regional (leg, arm, head) and systemic haemodynamics, and left ventricular (LV) volumes and functions were assessed in eight healthy males during: (1) 3 h control (normothermic condition); (2) 3 h of single-leg heating; (3) 3 h of two-leg heating; and (4) 2.5 h of whole-body heating. Leg, forearm, and extracranial blood flow increased in close association with local rises in temperature while brain perfusion remained unchanged. Increases in blood velocity with small to no changes in the conduit artery diameter underpinned the augmented limb and extracranial perfusion. In all heating conditions, Q ̇ $\dot Q$ increased in association with proportional elevations in systemic vascular conductance, related to enhanced blood flow, blood velocity, vascular conductance and kinetic energy in the limbs and head (all R2 ≥ 0.803; P < 0.001), but not in the brain. LV systolic (end-systolic elastance and twist) and diastolic functional profiles (untwisting rate), pulmonary ventilation and systemic aerobic metabolism were only altered in whole-body heating. These findings substantiate the idea that local hyperthermia-induced selective alterations in peripheral blood flow modulate the magnitude of flow to the heart and Q ̇ $\dot Q$ through changes in blood velocity and kinetic energy. Localised heat-activated events in the peripheral circulation therefore affect the human heart's output. KEY POINTS: Local and whole-body hyperthermia increases limb and systemic perfusion, but the underlying peripheral and central heat-sensitive mechanisms are not fully established. Here we investigated the regional (leg, arm and head) and systemic haemodynamics (cardiac output: Q ̇ $\dot Q$ ) during passive single-leg, two-leg and whole-body hyperthermia to determine the contribution of peripheral and central thermosensitive factors in the control of human circulation. Single-leg, two-leg, and whole-body hyperthermia induced graded increases in leg blood flow and Q ̇ $\dot Q$ . Brain blood flow, however, remained unchanged in all conditions. Ventilation, extracranial blood flow and cardiac systolic and diastolic functions only increased during whole-body hyperthermia. The augmented Q ̇ $\dot Q$ with hyperthermia was tightly related to increased limb and head blood velocity, flow and kinetic energy. The findings indicate that local thermosensitive mechanisms modulate regional blood velocity, flow and kinetic energy, thereby controlling the magnitude of flow to the heart and thus the coupling of peripheral and central circulation during hyperthermia.


Subject(s)
Cardiac Output , Hyperthermia , Humans , Male , Adult , Hyperthermia/physiopathology , Cardiac Output/physiology , Blood Flow Velocity/physiology , Regional Blood Flow/physiology , Fever/physiopathology , Young Adult , Hot Temperature , Hemodynamics
8.
Comput Biol Med ; 176: 108563, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38761498

ABSTRACT

Boundary conditions (BCs) is one pivotal factor influencing the accuracy of hemodynamic predictions on intracranial aneurysms (IAs) using computational fluid dynamics (CFD) modeling. Unfortunately, a standard procedure to secure accurate BCs for hemodynamic modeling does not exist. To bridge such a knowledge gap, two representative patient-specific IA models (Case-I and Case-II) were reconstructed and their blood flow velocity waveforms in the internal carotid artery (ICA) were measured by ultrasonic techniques and modeled by discrete Fourier transform (DFT). Then, numerical investigations were conducted to explore the appropriate number of samples (N) for DFT modeling to secure the accurate BC by comparing a series of hemodynamic parameters using in-vitro validated CFD modeling. Subsequently, a comprehensive comparison in hemodynamic characteristics under patient-specific BCs and a generalized BC based on a one-dimensional (1D) model was conducted to reinforce the understanding that a patient-specific BC is pivotal for accurate hemodynamic risk evaluations on IA pathophysiology. In addition, the influence of the variance of heart rate/cardiac pulsatile period on hemodynamic characteristics in IA models was studied preliminarily. The results showed that N ≥ 16 for DFT model is a decent choice to secure the proper BC profile to calculate time-averaged hemodynamic parameters, while more data points such as N ≥ 36 can ensure the accuracy of instantaneous hemodynamic predictions. In addition, results revealed the generalized BC could overestimate or underestimate the hemodynamic risks on IAs significantly; thus, patient-specific BCs are highly recommended for hemodynamic modeling for IA risk evaluation. Furthermore, this study discovered the variance of heart rate has rare influences on hemodynamic characteristics in both instantaneous and time-averaged parameters under the assumption of an identical blood flow rate.


Subject(s)
Hemodynamics , Intracranial Aneurysm , Models, Cardiovascular , Intracranial Aneurysm/physiopathology , Intracranial Aneurysm/diagnostic imaging , Humans , Hemodynamics/physiology , Blood Flow Velocity/physiology , Ultrasonography/methods , Male , Carotid Artery, Internal/physiopathology , Carotid Artery, Internal/diagnostic imaging , Cerebrovascular Circulation/physiology , Fourier Analysis , Computer Simulation , Female
9.
Sci Rep ; 14(1): 11317, 2024 05 17.
Article in English | MEDLINE | ID: mdl-38760455

ABSTRACT

Uncertainty quantification is becoming a key tool to ensure that numerical models can be sufficiently trusted to be used in domains such as medical device design. Demonstration of how input parameters impact the quantities of interest generated by any numerical model is essential to understanding the limits of its reliability. With the lattice Boltzmann method now a widely used approach for computational fluid dynamics, building greater understanding of its numerical uncertainty characteristics will support its further use in science and industry. In this study we apply an in-depth uncertainty quantification study of the lattice Boltzmann method in a canonical bifurcating geometry that is representative of the vascular junctions present in arterial and venous domains. These campaigns examine how quantities of interest-pressure and velocity along the central axes of the bifurcation-are influenced by the algorithmic parameters of the lattice Boltzmann method and the parameters controlling the values imposed at inlet velocity and outlet pressure boundary conditions. We also conduct a similar campaign on a set of personalised vessels to further illustrate the application of these techniques. Our work provides insights into how input parameters and boundary conditions impact the velocity and pressure distributions calculated in a simulation and can guide the choices of such values when applied to vascular studies of patient specific geometries. We observe that, from an algorithmic perspective, the number of time steps and the size of the grid spacing are the most influential parameters. When considering the influence of boundary conditions, we note that the magnitude of the inlet velocity and the mean pressure applied within sinusoidal pressure outlets have the greatest impact on output quantities of interest. We also observe that, when comparing the magnitude of variation imposed in the input parameters with that observed in the output quantities, this variability is particularly magnified when the input velocity is altered. This study also demonstrates how open-source toolkits for validation, verification and uncertainty quantification can be applied to numerical models deployed on high-performance computers without the need for modifying the simulation code itself. Such an ability is key to the more widespread adoption of the analysis of uncertainty in numerical models by significantly reducing the complexity of their execution and analysis.


Subject(s)
Algorithms , Models, Cardiovascular , Humans , Uncertainty , Blood Flow Velocity/physiology , Computer Simulation , Hydrodynamics , Hemodynamics
10.
Jpn J Ophthalmol ; 68(3): 211-215, 2024 May.
Article in English | MEDLINE | ID: mdl-38609716

ABSTRACT

PURPOSE: To investigate the association between the arm-to-choroidal circulation time (ACT) on indocyanine green angiography (IA) and clinical profile in patients with polypoidal choroidal vasculopathy (PCV). STUDY DESIGN: Single-center retrospective study. METHODS: We included 38 eyes of 38 patients with PCV diagnosed using multimodal imaging and did not undergo previous treatment. All patients were treated with monthly aflibercept injections for 3 months and treat-and-extend regimens for the subsequent 12 months. Posterior vortex vein ACT was assessed on the first visit using Heidelberg IA. The patients were divided into two groups: ACT ≥20 s (L group; eight eyes) and ACT <20 s (S group; 30 eyes). The clinical profiles before and after treatment were analyzed to assess associations with ACT. RESULTS: The mean ACT was 16.39±3.3 s (L group: 21.25±1.49 s, women:men=2:6, mean age: 77.3±6.5 years; S group: 15.10±2.17 s, women:men=7:23, mean age: 75.5±6.9 years). No significant difference was observed in the mean subfoveal choroidal thickness between the L and the S groups (176±75 µm vs. 230±79 µm, P=0.10). However, there were significant differences between the L and S groups in retinal fluid accumulation and hemorrhage recurrence (eight/eight eyes, 100% vs. 13/30 eyes, 43%, P<0.001), mean aflibercept injections (8.8±1.6 vs. 7.0±1.6, P<0.01) during the 12-month period, and the number of polypoidal lesions (1.8±0.7 vs. 1.3±0.5, P<0.05). CONCLUSION: Patients with PCV and ACT >20 s are more likely to experience exudative change recurrence in the retina during treatment because they have more polypoidal lesions.


Subject(s)
Choroid , Fluorescein Angiography , Fundus Oculi , Intravitreal Injections , Polyps , Receptors, Vascular Endothelial Growth Factor , Recombinant Fusion Proteins , Tomography, Optical Coherence , Visual Acuity , Humans , Female , Male , Retrospective Studies , Choroid/blood supply , Choroid/diagnostic imaging , Aged , Fluorescein Angiography/methods , Tomography, Optical Coherence/methods , Polyps/diagnosis , Polyps/drug therapy , Polyps/physiopathology , Receptors, Vascular Endothelial Growth Factor/therapeutic use , Receptors, Vascular Endothelial Growth Factor/administration & dosage , Recombinant Fusion Proteins/administration & dosage , Recombinant Fusion Proteins/therapeutic use , Indocyanine Green/administration & dosage , Follow-Up Studies , Choroidal Neovascularization/drug therapy , Choroidal Neovascularization/diagnosis , Choroidal Neovascularization/physiopathology , Coloring Agents/administration & dosage , Aged, 80 and over , Choroid Diseases/diagnosis , Choroid Diseases/drug therapy , Choroid Diseases/physiopathology , Angiogenesis Inhibitors/administration & dosage , Angiogenesis Inhibitors/therapeutic use , Regional Blood Flow/physiology , Multimodal Imaging , Blood Flow Velocity/physiology , Polypoidal Choroidal Vasculopathy
11.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(2): 351-359, 2024 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-38686417

ABSTRACT

In this work, we investigated the influence of the bifurcation geometry of the iliac artery on the propagation properties of the pulse wave, and applied software to establish the straight bifurcation and curved bifurcation bi-directional fluid-solid coupling finite element analysis models based on the iliac artery, and compared and analyzed the influence of the bifurcation angle of the blood vessel on the propagation characteristics of the pulse wave. It was found that the bifurcation geometry had a significant effect on the pulse wave propagation in the iliac arteries, and the pressure and velocity pulse wave amplitudes predicted by these two models had a good agreement with that before the vessel bifurcation in a cardiac cycle. The curvilinear bifurcation model predicted the pulse wave amplitude to be lower and the pressure drop to be smaller after the bifurcation, which was more in line with the actual situation of the human body. In addition, the bifurcation point is accompanied by the stress concentration phenomenon in the vessel wall, and there is a transient increase in the velocity pulse waveform amplitude, which was consistent with the fact that the bifurcation site is prone to phenomena such as arterial stenosis and hardening. The preliminary results of this paper will provide some reference for the use of pulse waveforms in the diagnosis of arterial diseases.


Subject(s)
Finite Element Analysis , Iliac Artery , Models, Cardiovascular , Pulse Wave Analysis , Humans , Iliac Artery/physiology , Blood Pressure/physiology , Pulsatile Flow/physiology , Blood Flow Velocity/physiology , Computer Simulation
12.
Ultrasonics ; 140: 107307, 2024 May.
Article in English | MEDLINE | ID: mdl-38579486

ABSTRACT

BACKGROUND AND OBJECTIVE: With the development of advanced clutter-filtering techniques by singular value decomposition (SVD) and leveraging favorable acquisition settings such as open-chest imaging by a linear high-frequency probe and plane waves, several studies have shown the feasibility of cardiac flow measurements during the entire cardiac cycle, ranging from coronary flow to myocardial perfusion. When applying these techniques in a routine clinical setting, using transthoracic ultrasound imaging, new challenges emerge. Firstly, a smaller aperture is needed that can fit between ribs. Consequently, diverging waves are employed instead of plane waves to achieve an adequate field of view. Secondly, to ensure imaging at a larger depth, the maximum pulse repetition frequency has to be reduced. Lastly, in comparison to the open-chest scenario, tissue motion induced by the heartbeat is significantly stronger. The latter complicates substantially the distinction between clutter and blood signals. METHODS: This study investigates a strategy to overcome these challenges by diverging wave imaging with an optimal number of tilt angles, in combination with dedicated clutter-filtering techniques. In particular, a novel, adaptive, higher-order SVD (HOSVD) clutter filter, which utilizes spatial, temporal, and angular information of the received ultrasound signals, is proposed to enhance clutter and blood separation. RESULTS: When non-negligible tissue motion is present, using fewer tilt angles not only reduces the decorrelation between the received waveforms but also allows for collecting more temporal samples at a given ensemble duration, contributing to improved Doppler performance. The addition of a third angular dimension enables the application of HOSVD, providing greater flexibility in selecting blood separation thresholds from a 3-D tensor. This differs from the conventional threshold selection method in a 2-D spatiotemporal space using SVD. Exhaustive threshold search has shown a significant improvement in Contrast and Contrast-to-Noise ratio for Power Doppler images filtered with HOSVD compared to the SVD-based clutter filter. CONCLUSION: With the improved settings, the obtained Power Doppler images show the feasibility of measuring coronary flow under the influence of non-negligible tissue motion in both in vitro and ex vivo.


Subject(s)
Coronary Circulation , Coronary Circulation/physiology , Phantoms, Imaging , Animals , Humans , Algorithms , Echocardiography, Doppler/methods , Image Processing, Computer-Assisted/methods , Blood Flow Velocity/physiology , Swine
13.
Invest Ophthalmol Vis Sci ; 65(4): 40, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38683566

ABSTRACT

Purpose: This study explored the relationship among microvascular parameters as delineated by optical coherence tomography angiography (OCTA) and retinal perfusion. Here, we introduce a versatile framework to examine the interplay between the retinal vascular structure and function by generating virtual vasculatures from central retinal vessels to macular capillaries. Also, we have developed a hemodynamics model that evaluates the associations between vascular morphology and retinal perfusion. Methods: The generation of the vasculature is based on the distribution of four clinical parameters pertaining to the dimension and blood pressure of the central retinal vessels, constructive constrained optimization, and Voronoi diagrams. Arterial and venous trees are generated in the temporal retina and connected through three layers of capillaries at different depths in the macula. The correlations between total retinal blood flow and macular flow fraction and vascular morphology are derived as Spearman rank coefficients, and uncertainty from input parameters is quantified. Results: A virtual cohort of 200 healthy vasculatures was generated. Means and standard deviations for retinal blood flow and macular flow fraction were 20.80 ± 7.86 µL/min and 15.04% ± 5.42%, respectively. Retinal blood flow was correlated with vessel area density, vessel diameter index, fractal dimension, and vessel caliber index. The macular flow fraction was not correlated with any morphological metrics. Conclusions: The proposed framework is able to reproduce vascular networks in the macula that are morphologically and functionally similar to real vasculature. The framework provides quantitative insights into how macular perfusion can be affected by changes in vascular morphology delineated on OCTA.


Subject(s)
Fluorescein Angiography , Regional Blood Flow , Retinal Vessels , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Retinal Vessels/diagnostic imaging , Retinal Vessels/physiology , Retinal Vessels/anatomy & histology , Fluorescein Angiography/methods , Regional Blood Flow/physiology , Hemodynamics/physiology , Blood Flow Velocity/physiology , Male , Female , Adult , Macula Lutea/blood supply , Macula Lutea/diagnostic imaging , Blood Pressure/physiology
14.
Physiol Rep ; 12(9): e16027, 2024 May.
Article in English | MEDLINE | ID: mdl-38684421

ABSTRACT

Resistance breathing may restore cardiac output (CO) and cerebral blood flow (CBF) during hypovolemia. We assessed CBF and cerebral autoregulation (CA) during tilt, resistance breathing, and paced breathing in 10 healthy subjects. Blood velocities in the internal carotid artery (ICA), middle cerebral arteries (MCA, four subjects), and aorta were measured by Doppler ultrasound in 30° and 60° semi-recumbent positions. ICA blood flow and CO were calculated. Arterial blood pressure (ABP, Finometer), and end-tidal CO2 (ETCO2) were recorded. ICA blood flow response was assessed by mixed-models regression analysis. The synchronization index (SI) for the variable pairs ABP-ICA blood velocity, ABP-MCA velocities in 0.005-0.08 Hz frequency interval was calculated as a measure of CA. Passive tilting from 30° to 60° resulted in 12% decrease in CO (p = 0.001); ICA blood flow tended to fall (p = 0.04); Resistance breathing restored CO and ICA blood flow despite a 10% ETCO2 drop. ETCO2 and CO contributed to ICA blood flow variance (adjusted R2: 0.9, p < 0.0001). The median SI was low (<0.2) indicating intact CA, confirmed by surrogate date testing. The peak SI was transiently elevated during resistance breathing in the 60° position. Resistance breathing may transiently reduce CA efficiency. Paced breathing did not restore CO or ICA blood flow.


Subject(s)
Cerebrovascular Circulation , Homeostasis , Humans , Male , Cerebrovascular Circulation/physiology , Homeostasis/physiology , Pilot Projects , Adult , Female , Blood Flow Velocity/physiology , Middle Cerebral Artery/physiology , Middle Cerebral Artery/diagnostic imaging , Cardiac Output/physiology , Healthy Volunteers , Carotid Artery, Internal/physiology , Carotid Artery, Internal/diagnostic imaging , Blood Pressure/physiology
15.
Int J Cardiol ; 408: 132084, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38653434

ABSTRACT

BACKGROUND: In congenital aortic valve disease, quantifying aortic regurgitation (AR) varies by the measurement site. Our study aimed to identify the optimal site for AR assessment using 2D and 4D MR flow measurements, with a focus on vortices. METHODS: We retrospectively analysed 31 patients with congenital aortic valve disease, performing 2D and 4D MR flow measurements at the aortic valve, sinotubular junction (STJ), ascending aorta (AAo), and using midpulmonary artery measurements as a reference. We assessed percentage AR and net forward volumes, calculated linear correlations, and plotted Bland-Altman plots. Net forward flow at all aortic sites were correlated with the main pulmonary artery. Differences in AR between 2D and 4D flows were linked to vortices detected by 4D streamlines. RESULTS: The best agreement in % AR between 2D and 4D flows was at the aortic valve (mean difference 4D2D -2.9%, limits of agreement 8.7% to -14.3%; r2 = 0.7). Correlations weakened at STJ and AAo. Vortices in the ascending aorta led to AR overestimation in 2D measurements. Net forward flow at the aortic valve by 4D flow correlated closer with main pulmonary artery than did 2D flow. (Mean difference for 2D and 4D MR flow 7.5 ml and 4.2 ml, respectively). CONCLUSIONS: For congenital aortic valve disease, the most accurate AR quantification occurs at the aortic valve using 2D and 4D MR flow. Notably, vortices in the ascending aorta can result in AR overestimation with 2D MR flow.


Subject(s)
Aortic Valve Insufficiency , Humans , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Retrospective Studies , Female , Male , Adult , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Aortic Valve/physiopathology , Magnetic Resonance Imaging, Cine/methods , Blood Flow Velocity/physiology , Middle Aged , Adolescent , Young Adult , Child , Aortic Valve Disease/diagnostic imaging
16.
Ultrasound Med Biol ; 50(7): 1020-1027, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38594125

ABSTRACT

OBJECTIVE: This study aimed to investigate the impact of microbubble degradation and flow velocity on Sub-Harmonic Aided Pressure Estimation (SHAPE), and to explore the correlation between subharmonic amplitude and pressure as a single factor. METHODS: We develop an open-loop vascular phantom platform system and utilize a commercial ultrasound machine and microbubbles for subharmonic imaging. Subharmonic amplitude was measured continuously at constant pressure and flow velocity to assess the impact of microbubble degradation. Flow velocity was varied within a range of 4-14 cm/s at constant pressure to investigate its relationship to subharmonic amplitude. Furthermore, pressure was varied within a range of 10-110 mm Hg at constant flow velocity to assess its isolated effect on subharmonic amplitude. RESULTS: Under constant pressure and flow velocity, subharmonic amplitude exhibited a continuous decrease at an average rate of 0.221 dB/min, signifying ongoing microbubble degradation during the experimental procedures. Subharmonic amplitude demonstrated a positive correlation with flow velocity, with a variation ratio of 0.423 dB/(cm/s). Under controlled conditions of microbubble degradation and flow velocity, a strong negative linear correlation was observed between pressure and subharmonic amplitude across different Mechanical Index (MI) settings (all R2 > 0.90). The sensitivity of SHAPE was determined to be 0.025 dB/mmHg at an MI of 0.04. CONCLUSION: The assessment of SHAPE sensitivity is affected by microbubble degradation and flow velocity. Excluding the aforementioned influencing factors, a strong linear negative correlation between pressure and subharmonic amplitude was still evident, albeit with a sensitivity coefficient lower than previously reported values.


Subject(s)
Microbubbles , Phantoms, Imaging , Blood Flow Velocity/physiology , Pressure , Ultrasonography/methods , Contrast Media
17.
PLoS One ; 19(3): e0298587, 2024.
Article in English | MEDLINE | ID: mdl-38478550

ABSTRACT

Episodic increases in cerebral blood flow (CBF) are thought to contribute to improved cerebrovascular function and health. Head-out water immersion (HOWI) may be a useful modality to increase CBF secondary to the hydrostatic pressure placed on the body. However, it is unclear whether water temperatures common to the general public elicit similar cerebrovascular responses. We tested the hypothesis that mean middle cerebral artery blood velocity (MCAvmean) and cerebrovascular reactivity to CO2 (CVRCO2) would be higher during an acute bout of thermoneutral (TN; 35°C) vs. cool (COOL; 25°C) HOWI. Ten healthy participants (age: 23±3 y; 4 women) completed two randomized HOWI visits. Right MCAvmean, end-tidal CO2 (PETCO2) mean arterial pressure (MAP), and MCA conductance (MCAvmean/MAP) were continuously recorded. CVRCO2 was assessed using a stepped hypercapnia protocol before (PRE), at 30 minutes of HOWI (HOWI), immediately after HOWI (POST-1), and 45 minutes after HOWI (POST-2). Absolute values are reported as mean ± SD. MCAvmean, PETCO2, MAP, and CVRCO2 were not different between conditions at any timepoint (all P≥0.17). In COOL, MCAvmean increased from PRE (61±9 cm/s) during HOWI (68±11 cm/s), at POST-1 (69±11 cm/s), and POST-2 (72±8 cm/s) (all P<0.01), and in TN from PRE to POST-1 (66±13 vs. 71±14 cm/s; P = 0.05). PETCO2 did not change over time in either condition. In COOL, MAP increased from PRE (85±5 mmHg) during HOWI (101±4 mmHg), at POST-1 (97±7 mmHg), and POST-2 (96±9 mmHg), and in TN from PRE (88±5 mmHg) at HOWI (98±7 mmHg) and POST-1 (99±8 mmHg) (all P<0.01). In COOL, CVRCO2 increased from PRE to HOWI (1.66±0.55 vs. 1.92±0.52 cm/s/mmHg; P = 0.04). MCA conductance was not different between or within conditions. These data indicate that 30 minutes of cool HOWI augments MCAvmean and that the increase in MCAvmean persists beyond cool HOWI. However, cool HOWI does not alter CVRCO2 in healthy young adults.


Subject(s)
Carbon Dioxide , Hypercapnia , Adult , Female , Humans , Young Adult , Blood Flow Velocity/physiology , Cerebrovascular Circulation/physiology , Immersion , Middle Cerebral Artery/physiology , Pilot Projects , Water , Male
18.
Ultrasound Med Biol ; 50(6): 817-824, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38429202

ABSTRACT

BACKGROUND: Blood flow to the brain is a critical physiological function and is useful to monitor in critical care settings. Despite that, a surrogate is most likely measured instead of actual blood flow. Such surrogates include velocity measurements in the carotid artery and systemic blood pressure, even though true blood flow can actually be obtained using MRI and other modalities. Ultrasound is regularly used to measure blood flow and is, under certain conditions, able to provide quantitative volumetric blood flow in milliliters per minute. Unfortunately, most times the resulting flow data is not valid due to unmet assumptions (such as flow profile and angle correction). Color flow, acquired in three dimensions, has been shown to yield quantitative blood flow without any assumptions (3DVF). METHODS: Here we are testing whether color flow can perform during physiological conditions common to severe injury. Specifically, we are simulating severe traumatic brain injury (epidural hematoma) as well as hemorrhagic shock with 50% blood loss. Blood flow was measured in the carotid artery of a cohort of 7 Yorkshire mix pigs (40-60 kg) using 3DVF (4D16L, LOGIQ 9, GE HealthCare, Milwaukee, WI, USA) and compared to an invasive flow meter (TS420, Transonic Systems Inc., Ithaca, NY, USA). RESULTS: Six distinct physiological conditions were achieved: baseline, hematoma, baseline 2, hemorrhagic shock, hemorrhagic shock plus hematoma, and post-hemorrhage resuscitation. Mean cerebral oxygen extraction ratio varied from 40.6% ± 13.0% of baseline to a peak of 68.4% ± 15.6% during hemorrhagic shock. On average 3DVF estimated blood flow with a bias of -9.6% (-14.3% root mean squared error) relative to the invasive flow meter. No significant flow estimation error was detected during phases of flow reversal, that was seen in the carotid artery during traumatic conditions. The invasive flow meter showed a median error of -11.5% to 39.7%. CONCLUSIONS: Results suggest that absolute volumetric carotid blood flow to the brain can be obtained and potentially become a more specific biomarker related to cerebral hemodynamics than current surrogate markers.


Subject(s)
Brain , Cerebrovascular Circulation , Hemodynamics , Cerebrovascular Circulation/physiology , Animals , Swine , Hemodynamics/physiology , Brain/diagnostic imaging , Brain/blood supply , Brain/metabolism , Blood Flow Velocity/physiology , Brain Injuries, Traumatic/diagnostic imaging , Brain Injuries, Traumatic/physiopathology , Brain Injuries, Traumatic/metabolism
19.
J Appl Physiol (1985) ; 136(5): 1105-1112, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38482574

ABSTRACT

During spaceflight, fluids shift headward, causing internal jugular vein (IJV) distension and altered hemodynamics, including stasis and retrograde flow, that may increase the risk of thrombosis. This study's purpose was to determine the effects of acute exposure to weightlessness (0-G) on IJV dimensions and flow dynamics. We used two-dimensional (2-D) ultrasound to measure IJV cross-sectional area (CSA) and Doppler ultrasound to characterize venous blood flow patterns in the right and left IJV in 13 healthy participants (6 females) while 1) seated and supine on the ground, 2) supine during 0-G parabolic flight, and 3) supine during level flight (at 1-G). On Earth, in 1-G, moving from seated to supine posture increased CSA in both left (+62 [95% CI: +42 to 81] mm2, P < 0.0001) and right (+86 [95% CI: +58 to 113] mm2, P < 0.00012) IJV. Entry into 0-G further increased IJV CSA in both left (+27 [95% CI: +5 to 48] mm2, P = 0.02) and right (+30 [95% CI: +0.3 to 61] mm2, P = 0.02) relative to supine in 1-G. We observed stagnant flow in the left IJV of one participant during 0-G parabolic flight that remained during level flight but was not present during any imaging during preflight measures in the seated or supine postures; normal venous flow patterns were observed in the right IJV during all conditions in all participants. Alterations to cerebral outflow dynamics in the left IJV can occur during acute exposure to weightlessness and thus, may increase the risk of venous thrombosis during any duration of spaceflight.NEW & NOTEWORTHY The absence of hydrostatic pressure gradients in the vascular system and loss of tissue weight during weightlessness results in altered flow dynamics in the left internal jugular vein in some astronauts that may contribute to an increased risk of thromboembolism during spaceflight. Here, we report that the internal jugular veins distend bilaterally in healthy participants and that flow stasis can occur in the left internal jugular vein during acute weightlessness produced by parabolic flight.


Subject(s)
Jugular Veins , Weightlessness , Humans , Female , Jugular Veins/physiology , Jugular Veins/diagnostic imaging , Male , Adult , Weightlessness/adverse effects , Space Flight/methods , Hemodynamics/physiology , Blood Flow Velocity/physiology , Supine Position/physiology , Young Adult
20.
Pediatr Cardiol ; 45(5): 998-1006, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38519622

ABSTRACT

We sought to evaluate the potential clinical role of 4D-flow cardiac magnetic resonance (CMR)-derived energetics and flow parameters in a cohort of patients' post-Fontan palliation. In patients with Fontan circulation who underwent 4D-Flow CMR, streamlines distribution was evaluated, as well a 4D-flow CMR-derived energetics parameters as kinetic energy (KE) and energy loss (EL) normalized by volume. EL/KE index as a marker of flow efficiency was also calculated. Cardiopulmonary exercise test (CPET) was also performed in a subgroup of patients. The population study included 55 patients (mean age 22 ± 11 years). The analysis of the streamlines revealed a preferential distribution of the right superior vena cava flow for the right pulmonary artery (62.5 ± 35.4%) and a mild preferential flow for the left pulmonary artery (52.3 ± 40.6%) of the inferior vena cave-pulmonary arteries (IVC-PA) conduit. Patients with heart failure (HF) presented lower IVC/PA-conduit flow (0.75 ± 0.5 vs 1.3 ± 0.5 l/min/m2, p = 0.004) and a higher mean flow-jet angle of the IVC-PA conduit (39.2 ± 22.8 vs 15.2 ± 8.9, p < 0.001) than the remaining patients. EL/KE index correlates inversely with VO2/kg/min: R: - 0.45, p = 0.01 peak, minute ventilation (VE) R: - 0.466, p < 0.01, maximal voluntary ventilation: R:0.44, p = 0.001 and positively with the physiological dead space to the tidal volume ratio (VD/VT) peak: R: 0.58, p < 0.01. From our data, lower blood flow in IVC/PA conduit and eccentric flow was associated with HF whereas higher EL/KE index was associated with reduced functional capacity and impaired lung function. Larger studies are needed to confirm our results and to further improve the prognostic role of the 4D-Flow CMR in this challenging population.


Subject(s)
Exercise Test , Fontan Procedure , Heart Defects, Congenital , Pulmonary Artery , Humans , Female , Male , Heart Defects, Congenital/surgery , Heart Defects, Congenital/physiopathology , Young Adult , Exercise Test/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Adolescent , Adult , Magnetic Resonance Imaging, Cine/methods , Child , Vena Cava, Superior/diagnostic imaging , Blood Flow Velocity/physiology , Heart Failure/physiopathology , Heart Failure/surgery , Vena Cava, Inferior/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...