Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.534
Filter
1.
BMC Med Res Methodol ; 24(1): 126, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831294

ABSTRACT

BACKGROUND: A growing number of older adults (ages 65+) live with Type 1 diabetes. Simultaneously, technologies such as continuous glucose monitoring (CGM) have become standard of care. There is thus a need to understand better the complex dynamics that promote use of CGM (and other care innovations) over time in this age group. Our aim was to adapt methods from systems thinking, specifically a participatory approach to system dynamics modeling called group model building (GMB), to model the complex experiences that may underlie different trajectories of CGM use among this population. Herein, we report on the feasibility, strengths, and limitations of this methodology. METHODS: We conducted a series of GMB workshops and validation interviews to collect data in the form of questionnaires, diagrams, and recordings of group discussion. Data were integrated into a conceptual diagram of the "system" of factors associated with uptake and use of CGM over time. We evaluate the feasibility of each aspect of the study, including the teaching of systems thinking to older adult participants. We collected participant feedback on positive aspects of their experiences and areas for improvement. RESULTS: We completed nine GMB workshops with older adults and their caregivers (N = 33). Each three-hour in-person workshop comprised: (1) questionnaires; (2) the GMB session, including both didactic components and structured activities; and (3) a brief focus group discussion. Within the GMB session, individual drawing activities proved to be the most challenging for participants, while group activities and discussion of relevant dynamics over time for illustrative (i.e., realistic but not real) patients yielded rich engagement and sufficient information for system diagramming. Study participants liked the opportunity to share experiences with peers, learning and enhancing their knowledge, peer support, age-specific discussions, the workshop pace and structure, and the systems thinking framework. Participants gave mixed feedback on the workshop duration. CONCLUSIONS: The study demonstrates preliminary feasibility, acceptability, and the value of GMB for engaging older adults about key determinants of complex health behaviors over time. To our knowledge, few studies have extended participatory systems science methods to older adult stakeholders. Future studies may utilize this methodology to inform novel approaches for supporting health across the lifespan.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1 , Humans , Diabetes Mellitus, Type 1/therapy , Diabetes Mellitus, Type 1/psychology , Aged , Female , Male , Blood Glucose Self-Monitoring/methods , Systems Analysis , Surveys and Questionnaires , Feasibility Studies
2.
Diabetes Metab Res Rev ; 40(5): e3826, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38824455

ABSTRACT

INTRODUCTION: Early and tight glycaemic control is crucial to prevent long-term complications of Type 1 Diabetes (T1D). The aim of our study was to compare glucose metrics, including Time In Tight Range (TITR), in a real-world setting. METHODS: We performed a single-centre cross-sectional study in 534 children and adolescents with T1D. Participants were divided into four groups (multiple daily injections + real-time Continuous glucose monitoring (CGM), multiple daily injections + intermittently scanned CGM, sensor augmented pump (SAP), and Advanced Hybrid Closed-Loop (AHCL). Demographical and clinical data were collected and analysed. RESULTS: The group with AHCL showed significantly higher Time In Range (TIR) (71.31% ± 10.88) than SAP (57.82% ± 14.98; p < 0.001), MDI + rtCGM (54.56% ± 17.04; p < 0.001) and MDI + isCGM (52.17% ± 19.36; p < 0.001) groups with a lower Time Above Range (p < 0.001). The group with AHCL also showed lower Time Below Range than MDI + isCGM and SAP groups (p < 0.01). The overall TITR was 37% ± 14 with 19% of participants who reached a TITR ≥50% with a mean TIR of 81%. AHCL had significantly higher TITR (45.46% ± 11.77) than SAP (36.25% ± 13.53; p < 0.001), MDI + rtCGM (34.03% ± 13.89; p < 0.001) and MDI + isCGM (33.37% ± 15.84; p < 0.001) groups with a lower Coefficient of Variation (p < 0.001). CONCLUSIONS: Our study indicates that AHCL ensures a better glycaemic control with an improvement in both TIR and TITR, along with a reduction in CV. Implementation of automated insulin delivery systems should be considered in the treatment of children and adolescents with T1D.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 1 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Humans , Diabetes Mellitus, Type 1/drug therapy , Cross-Sectional Studies , Child , Adolescent , Female , Male , Blood Glucose Self-Monitoring/methods , Blood Glucose/analysis , Insulin/administration & dosage , Insulin/therapeutic use , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Glycemic Control/methods , Glycated Hemoglobin/analysis , Follow-Up Studies , Prognosis , Biomarkers/analysis , Hypoglycemia/prevention & control
3.
Cleve Clin J Med ; 91(6): 353-360, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38830704

ABSTRACT

Diabetes technology is evolving rapidly and is changing the way both patients and clinicians approach the management of diabetes. With more devices gaining US Food and Drug Administration approval and insurance coverage expanding, these new technologies are being widely adopted by people living with diabetes. We provide a summary of the commonly available devices in the market today that clinicians will likely encounter. This includes continuous glucose monitors (CGMs); connected insulin pens, caps, and buttons; and insulin pumps. Clinicians' awareness of and familiarity with this technology will enhance its accessibility for patients with diabetes.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus , Insulin Infusion Systems , Humans , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus/therapy , Diabetes Mellitus/drug therapy , Insulin/administration & dosage , Insulin/therapeutic use , Blood Glucose/analysis
4.
Front Endocrinol (Lausanne) ; 15: 1374496, 2024.
Article in English | MEDLINE | ID: mdl-38836229

ABSTRACT

Aims: The present study aimed to investigate the accuracy of the Glunovo® real-time continuous glucose monitoring system (rtCGMS). Methods: We conducted a 14-day interstitial glucose level monitoring using Glunovo® rtCGMS on thirty hospitalized patients with type 2 diabetes. The flash glucose monitoring (FGM) was used as a self-control. Consistency tests, error grid analysis, and calculation of the mean absolute relative difference (MARD) were performed using R software to assess the accuracy of Glunovo® rtCGMS. Results: Glunovo® exhibited an overall MARD value of 8.89% during hospitalization, compared to 10.42% for FGM. The overall percentages of glucose values within ±10%/10, ± 15%/15, ± 20%/20, ± 30%/30, and ±40%/40 of the venous blood glucose reference value were 63.34%, 81.31%, 90.50%, 97.29%, and 99.36% for Glunovo®, respectively, compared with 61.58%, 79.63%, 88.31%, 96.22% and 99.23% for FGM. The Clarke Error Grid Analysis showed that 99.61% of Glunovo® glucose pairs and 100.00% of FGM glucose pairs within zones A and B. Conclusion: Our study confirms the superior accuracy of Glunovo® in monitoring blood glucose levels among hospitalized patients with type 2 diabetes.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 2 , Hospitalization , Humans , Diabetes Mellitus, Type 2/blood , Female , Blood Glucose Self-Monitoring/methods , Blood Glucose Self-Monitoring/instrumentation , Male , Middle Aged , Blood Glucose/analysis , Prospective Studies , Aged , Adult , Continuous Glucose Monitoring
5.
Front Endocrinol (Lausanne) ; 15: 1382920, 2024.
Article in English | MEDLINE | ID: mdl-38836230

ABSTRACT

Background: Tight glycemic control is essential for the normal growth and development of preschool children. The aim of our study was to evaluate the impact of advanced hybrid closed loop (AHCL) systems in a real-life setting in children younger than 6 years. Methods: We conducted a two-center prospective study. We enrolled 19 patients with a median age at disease onset of 2.6 years [interquartile range (IQR) 1.6; 4.4] and a median disease duration of 1.4 years (IQR 0.9; 2.8) who were switched to AHCL from multiple daily injections or open-loop insulin therapy and with a 6-month follow-up. Clinical data, sensor glycemic metrics, and pump settings were collected and analyzed. Results: After 6 months of follow-up, there was a significant reduction in median HbA1c (p = 0.0007) and glucose management indicator (p = 0.03). A reduction in both mild (>180 mg/dL) (p = 0.04) and severe (>250 mg/dL) (p = 0.01) hyperglycemia was observed after 1 month of auto mode, and in mild hyperglycemia, it persisted up to 6 months (p = 0.02). A small increase in time below range (<70 mg/dL) was observed (p = 0.04) without a significant difference in time <54 mg/dL (p = 0.73). Time in range increased significantly, reaching a 10% increment (p = 0.03) compared with baseline. A significant reduction in the average sensor glucose was observed (p = 0.01) while coefficient of glucose variability (CV%) remained stable (p = 0.12). No episodes of ketoacidosis or severe hypoglycemia have been recorded. Conclusion: AHCL systems are effective and safe for children younger than 6 years and should be considered as a valid therapeutic option from diabetes onset.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Humans , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 1/blood , Male , Child, Preschool , Female , Prospective Studies , Blood Glucose/analysis , Insulin/administration & dosage , Insulin/therapeutic use , Hypoglycemic Agents/therapeutic use , Hypoglycemic Agents/administration & dosage , Infant , Glycemic Control/methods , Follow-Up Studies , Blood Glucose Self-Monitoring/methods , Treatment Outcome , Hypoglycemia , Glycated Hemoglobin/analysis , Child
6.
Lancet Diabetes Endocrinol ; 12(6): 390-403, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38697182

ABSTRACT

BACKGROUND: Advanced hybrid closed loop (AHCL) therapy can improve glycaemic control in pregnant women with type 1 diabetes. However, data are needed on the efficacy and safety of AHCL systems as these systems, such as the MiniMed 780G, are not currently approved for use in pregnant women. We aimed to investigate whether the MiniMed 780G can improve glycaemic control with less hypoglycaemia in pregnant women with type 1 diabetes. METHODS: CRISTAL was a double-arm, parallel-group, open-label, randomised controlled trial conducted in secondary and tertiary care specialist endocrinology centres at 12 hospitals (11 in Belgium and one in the Netherlands). Pregnant women aged 18-45 years with type 1 diabetes were randomly assigned (1:1) to AHCL therapy (MiniMed 780G) or standard insulin therapy (standard of care) at a median of 10·1 (IQR 8·6-11·6) weeks of gestation. Randomisation was done centrally with minimisation dependent on baseline HbA1c, insulin administration method, and centre. Participants and study teams were not masked to group allocation. The primary outcome was proportion of time spent in the pregnancy-specific target glucose range (3·5-7·8 mmol/L), measured by continuous glucose monitoring (CGM) at 14-17 weeks, 20-23 weeks, 26-29 weeks, and 33-36 weeks. Key secondary outcomes were overnight time in target range, and time below glucose range (<3·5 mmol/L) overall and overnight. Analyses were conducted on an intention-to-treat basis. This trial is registered with ClinicalTrials.gov (NCT04520971). FINDINGS: Between Jan 15, 2021 and Sept 30, 2022, 101 participants were screened, and 95 were randomly assigned to AHCL therapy (n=46) or standard insulin therapy (n=49). 43 patients assigned to AHCL therapy and 46 assigned to standard insulin therapy completed the study. At baseline, 91 (95·8%) participants used insulin pumps, and the mean HbA1c was 6·5% (SD 0·6). The mean proportion of time spent in the target range (averaged over four time periods) was 66·5% (SD 10·0) in the AHCL therapy group compared with 63·2% (12·4) in the standard insulin therapy group (adjusted mean difference 1·88 percentage points [95% CI -0·82 to 4·58], p=0·17). Overnight time in the target range was higher (adjusted mean difference 6·58 percentage points [95% CI 2·31 to 10·85], p=0·0026), and time below range overall (adjusted mean difference -1·34 percentage points [95% CI, -2·19 to -0·49], p=0·0020) and overnight (adjusted mean difference -1·86 percentage points [95% CI -2·90 to -0·81], p=0·0005) were lower with AHCL therapy than with standard insulin therapy. Participants assigned to AHCL therapy reported higher treatment satisfaction. No unanticipated safety events occurred with AHCL therapy. INTERPRETATION: In pregnant women starting with tighter glycaemic control, AHCL therapy did not improve overall time in target range but improved overnight time in target range, reduced time below range, and improved treatment satisfaction. These data suggest that the MiniMed 780G can be safely used in pregnancy and provides some additional benefits compared with standard insulin therapy; however, it will be important to refine the algorithm to better align with pregnancy requirements. FUNDING: Diabetes Liga Research Fund and Medtronic.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Pregnancy in Diabetics , Humans , Female , Pregnancy , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 1/blood , Adult , Insulin/administration & dosage , Insulin/therapeutic use , Hypoglycemic Agents/therapeutic use , Hypoglycemic Agents/administration & dosage , Pregnancy in Diabetics/drug therapy , Pregnancy in Diabetics/blood , Blood Glucose/analysis , Blood Glucose/drug effects , Young Adult , Adolescent , Hypoglycemia/chemically induced , Glycemic Control/methods , Blood Glucose Self-Monitoring/methods
7.
BMJ Open ; 14(5): e075554, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38719319

ABSTRACT

OBJECTIVES: To assess the feasibility and change in clinical outcomes associated with continuous glucose monitoring (CGM) use among a rural population in Malawi living with type 1 diabetes. DESIGN: A 2:1 open randomised controlled feasibility trial. SETTING: Two Partners In Health-supported Ministry of Health-run first-level district hospitals in Neno, Malawi. PARTICIPANTS: 45 people living with type 1 diabetes (PLWT1D). INTERVENTIONS: Participants were randomly assigned to Dexcom G6 CGM (n=30) use or usual care (UC) (n=15) consisting of Safe-Accu glucose monitors and strips. Both arms received diabetes education. OUTCOMES: Primary outcomes included fidelity, appropriateness and severe adverse events. Secondary outcomes included change in haemoglobin A1c (HbA1c), acceptability, time in range (CGM arm only) SD of HbA1c and quality of life. RESULTS: Participants tolerated CGM well but were unable to change their own sensors which resulted in increased clinic visits in the CGM arm. Despite the hot climate, skin rashes were uncommon but cut-out tape overpatches were needed to secure the sensors in place. Participants in the CGM arm had greater numbers of dose adjustments and lifestyle change suggestions than those in the UC arm. Participants in the CGM arm wore their CGM on average 63.8% of the time. Participants in the UC arm brought logbooks to clinic 75% of the time. There were three hospitalisations all in the CGM arm, but none were related to the intervention. CONCLUSIONS: This is the first randomised controlled trial conducted on CGM in a rural region of a low-income country. CGM was feasible and appropriate among PLWT1D and providers, but inability of participants to change their own sensors is a challenge. TRIAL REGISTRATION NUMBER: PACTR202102832069874.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 1 , Feasibility Studies , Glycated Hemoglobin , Hospitals, District , Humans , Malawi , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/drug therapy , Female , Male , Blood Glucose Self-Monitoring/methods , Adult , Glycated Hemoglobin/analysis , Blood Glucose/analysis , Middle Aged , Quality of Life , Rural Population , Continuous Glucose Monitoring
8.
Front Endocrinol (Lausanne) ; 15: 1383483, 2024.
Article in English | MEDLINE | ID: mdl-38803475

ABSTRACT

1,5-Anhydroglucitol (1,5-AG) is sensitive to short-term glucose fluctuations and postprandial hyperglycemia, which has great potential in the clinical application of diabetes as a nontraditional blood glucose monitoring indicator. A large number of studies have found that 1,5-AG can be used to screen for diabetes, manage diabetes, and predict the perils of diabetes complications (diabetic nephropathy, diabetic cardiovascular disease, diabetic retinopathy, diabetic pregnancy complications, diabetic peripheral neuropathy, etc.). Additionally, 1,5-AG and ß cells are also associated with each other. As a noninvasive blood glucose monitoring indicator, salivary 1,5-AG has much more benefit for clinical application; however, it cannot be ignored that its detection methods are not perfect. Thus, a considerable stack of research is still needed to establish an accurate and simple enzyme assay for the detection of salivary 1,5-AG. More clinical studies will also be required in the future to confirm the normal reference range of 1,5-AG and its role in diabetes complications to further enhance the blood glucose monitoring system for diabetes.


Subject(s)
Deoxyglucose , Diabetes Complications , Humans , Diabetes Complications/diagnosis , Diabetes Complications/blood , Diabetes Complications/metabolism , Blood Glucose/analysis , Blood Glucose/metabolism , Diabetes Mellitus/blood , Diabetes Mellitus/diagnosis , Diabetes Mellitus/metabolism , Blood Glucose Self-Monitoring/methods , Biomarkers/blood , Biomarkers/analysis
9.
Rev Med Suisse ; 20(876): 1083-1086, 2024 May 29.
Article in French | MEDLINE | ID: mdl-38812341

ABSTRACT

The technologies used to measure blood glucose have significantly evolved the past few years, especially with the introduction of continuous interstitial glucose measurements, simplifying the management of the disease. More recently, there has been a lot of interest regarding some potential revolutionary methods, such as smartwatches, and glucose measurements in sweat, saliva, and even tears. In this article, we review the different technologies that are under development, and notice that although promising, they rest imprecise. False measurements can have fatal consequences for our patients. Nevertheless, these innovations are promising and have the potential to change the daily life of people with diabetes in the future.


Les technologies utilisées pour mesurer les glycémies des personnes présentant un diabète ont beaucoup évolué ces dernières années, avec notamment l'introduction des mesures interstitielles en continu, rendant le contrôle glycémique plus aisé. Depuis peu, il y a un intérêt croissant, notamment dans les médias, autour de potentielles méthodes révolutionnaires via des montres intelligentes, la sueur, la salive et même les larmes. Dans cet article, nous répertorions les différentes technologies en cours d'investigation et notons que plusieurs d'entre elles restent imprécises, empêchant leur utilisation pour nos patients diabétiques, chez qui des mesures incorrectes peuvent avoir de graves conséquences. Néanmoins, ces nouveautés sont prometteuses et ont le potentiel de changer le quotidien des personnes présentant un diabète dans le futur.


Subject(s)
Blood Glucose , Diabetes Mellitus , Humans , Blood Glucose/analysis , Diabetes Mellitus/blood , Diabetes Mellitus/diagnosis , Blood Glucose Self-Monitoring/methods , Blood Glucose Self-Monitoring/instrumentation , Sweat/chemistry , Saliva/chemistry , Glucose/analysis , Tears/chemistry
10.
Ter Arkh ; 96(3): 312-314, 2024 Apr 16.
Article in Russian | MEDLINE | ID: mdl-38713050

ABSTRACT

In the article "Point-of-care blood glucose testing: post-market performance assessment of the Accu-Chek Inform II hospital-use glucose meter," published in the Terapevticheskii Arkhiv journal, Vol. 95, No.12, 2023 (DOI: 10.26442/00403660.2023.12.202522), errors were made: the term "measurements at the place of treatment" was changed, as well as the section "Conflict of interest." At the request of the authors' team, errors in the conflict of interest and the wording of the term have been corrected, and the section "Information about the authors" has been updated. The publisher replaced the original version of the published article with the corrected one; the information on the website was also corrected. Correct text of the section "Conflict of interest": Conflict of interest. All authors are not employees or consultants of Roche Diagnostics and have not received any compensation from Roche Diagnostics. Correct wording of the term in Russian: "измерения по месту лечения". Changes were made to the title of the article in Russian: "Измерения глюкозы по месту лечения: пострегистрационное испытание госпитального глюкометра Акку-Чек Информ II", the text of the abstract, keywords, citation, in the text of the article, and abbreviations. Information of the place of work has been updated: Center for Laboratory Diagnostics of the Russian Children Clinical Hospital, a Branch of the Pirogov Russian National Research Medical University. The publisher apologizes to readers and authors for the errors and is confident that the correction of errors will ensure the correct perception and interpretation of the results of the study described in the text.


Subject(s)
Blood Glucose , Humans , Blood Glucose/analysis , Point-of-Care Systems , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , Point-of-Care Testing , Product Surveillance, Postmarketing/methods , Russia
11.
BMJ Open Diabetes Res Care ; 12(3)2024 May 15.
Article in English | MEDLINE | ID: mdl-38749509

ABSTRACT

INTRODUCTION: Manufacturer-supported didactic teaching programmes offer effective automated insulin delivery (AID) systems onboarding in children and young people (CYP) with type 1 diabetes (T1D). However, this approach has limited flexibility to accommodate the needs of families requiring additional support. RESEARCH DESIGN AND METHODS: Evaluate the efficacy of an inperson manufacturer-supported didactic teaching programme (Group A), in comparison to a flexible flipped learning approach delivered virtually or inperson (Group B). Retrospective analysis of CYP with T1D using continuous glucose monitoring (CGM), who were initiated on AID systems between 2021 and 2023. Compare CGM metrics from baseline to 90 days for both groups A and B. Additionally, compare the two groups for change in CGM metrics over the 90-day period (∆), patient demographics and onboarding time. RESULTS: Group A consisted of 74 CYP (53% male) with median age of 13.9 years and Group B 91 CYP (54% male) with median age of 12.7 years. From baseline to 90 days, Group A lowered mean (±SD) time above range (TAR, >10.0 mmol/L) from 47.6% (±15.0) to 33.2% (±15.0) (p<0.001), increased time in range (TIR, 3.9-10.0 mmol/L) from 50.4% (±14.0) to 64.7% (±10.2) (p<0.001). From baseline to 90 days, Group B lowered TAR from 51.3% (±15.1) to 34.5% (±11.3) (p<0.001) and increased TIR from 46.5% (±14.5) to 63.7% (±11.0) (p<0.001). There was no difference from baseline to 90 days for time below range (TBR, <3.9 mmol/L) for Group A and Group B. ∆ TAR, TIR and TBR for both groups were comparable. Group B consisted of CYP with higher socioeconomic deprivation, greater ethnic diversity and lower carer education achievement (p<0.05). The majority of Group B (n=79, 87%) chose virtual flipped learning, halving diabetes educator time and increasing onboarding cadence by fivefold. CONCLUSIONS: A flexible virtual flipped learning programme increases onboarding cadence and capacity to offer equitable AID system onboarding.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Humans , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 1/blood , Male , Child , Adolescent , Female , Insulin/administration & dosage , Insulin/therapeutic use , Retrospective Studies , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Blood Glucose Self-Monitoring/methods , Blood Glucose/analysis , Ethnicity , Socioeconomic Factors , Follow-Up Studies , Health Services Accessibility
12.
BMJ Open Diabetes Res Care ; 12(3)2024 May 10.
Article in English | MEDLINE | ID: mdl-38729771

ABSTRACT

INTRODUCTION: To characterize glucose levels during uncomplicated pregnancies, defined as pregnancy with a hemoglobin A1c <5.7% (<39 mmol/mol) in early pregnancy, and without a large-for-gestational-age birth, hypertensive disorders of pregnancy, or gestational diabetes mellitus (ie, abnormal oral glucose tolerance test). RESEARCH DESIGN AND METHODS: Two sites enrolled 937 pregnant individuals aged 18 years and older prior to reaching 17 gestational weeks; 413 had an uncomplicated pregnancy (mean±SD body mass index (BMI) of 25.3±5.0 kg/m2) and wore Dexcom G6 continuous glucose monitoring (CGM) devices throughout the observed gestational period. Mealtimes were voluntarily recorded. Glycemic levels during gestation were characterized using CGM-measured glycemic metrics. RESULTS: Participants wore CGM for a median of 123 days each. Glucose levels were nearly stable throughout all three trimesters in uncomplicated pregnancies. Overall mean±SD glucose during gestation was 98±7 mg/dL (5.4±0.4 mmol/L), median per cent time 63-120 mg/dL (3.5-6.7 mmol/L) was 86% (IQR: 82-89%), median per cent time <63 mg/dL (3.5 mmol/L) was 1.8%, median per cent time >120 mg/dL (6.7 mmol/L) was 11%, and median per cent time >140 mg/dL (7.8 mmol/L) was 2.5%. Mean post-prandial peak glucose was 126±22 mg/dL (7.0±1.2 mmol/L), and mean post-prandial glycemic excursion was 36±22 mg/dL (2.0±1.2 mmol/L). Higher mean glucose levels were low to moderately associated with pregnant individuals with higher BMIs (103±6 mg/dL (5.7±0.3 mmol/L) for BMI ≥30.0 kg/m2 vs 96±7 mg/dL (5.3±0.4 mmol/L) for BMI 18.5-<25 kg/m2, r=0.35). CONCLUSIONS: Mean glucose levels and time 63-120 mg/dL (3.5-6.7 mmol/L) remained nearly stable throughout pregnancy and values above 140 mg/dL (7.8 mmol/L) were rare. Mean glucose levels in pregnancy trend higher as BMI increases into the overweight/obesity range. The glycemic metrics reported during uncomplicated pregnancies represent treatment targets for pregnant individuals.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Humans , Female , Pregnancy , Blood Glucose/analysis , Adult , Blood Glucose Self-Monitoring/methods , Glycated Hemoglobin/analysis , Diabetes, Gestational/blood , Diabetes, Gestational/diagnosis , Glucose Tolerance Test , Young Adult , Follow-Up Studies , Biomarkers/blood , Biomarkers/analysis , Continuous Glucose Monitoring
13.
BMC Endocr Disord ; 24(1): 60, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711112

ABSTRACT

BACKGROUND: Worldwide, up to 20 % of hospitalised patients have diabetes mellitus. In-hospital dysglycaemia increases patient mortality, morbidity, and length of hospital stay. Improved in-hospital diabetes management strategies are needed. The DIATEC trial investigates the effects of an in-hospital diabetes team and operational insulin titration algorithms based on either continuous glucose monitoring (CGM) data or standard point-of-care (POC) glucose testing. METHODS: This is a two-armed, two-site, prospective randomised open-label blinded endpoint (PROBE) trial. We recruit non-critically ill hospitalised general medical and orthopaedic patients with type 2 diabetes treated with basal, prandial, and correctional insulin (N = 166). In both arms, patients are monitored by POC glucose testing and diabetes management is done by ward nurses guided by in-hospital diabetes teams. In one of the arms, patients are monitored in addition to POC glucose testing by telemetric CGM viewed by the in-hospital diabetes teams only. The in-hospital diabetes teams have operational algorithms to titrate insulin in both arms. Outcomes are in-hospital glycaemic and clinical outcomes. DISCUSSION: The DIATEC trial will show the glycaemic and clinical effects of in-hospital CGM handled by in-hospital diabetes teams with access to operational insulin titration algorithms in non-critically ill patients with type 2 diabetes. The DIATEC trial seeks to identify which hospitalised patients will benefit from CGM and in-hospital diabetes teams compared to POC glucose testing. This is essential information to optimise the use of healthcare resources before broadly implementing in-hospital CGM and diabetes teams. TRIAL REGISTRATION: Prospectively registered at ClinicalTrials.gov with identification number NCT05803473 on March 27th 2023.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 2 , Humans , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/blood , Blood Glucose/analysis , Blood Glucose Self-Monitoring/methods , Prospective Studies , Point-of-Care Testing , Female , Male , Hospitalization , Insulin/therapeutic use , Insulin/administration & dosage , Hypoglycemic Agents/therapeutic use , Patient Care Team , Adult , Middle Aged , Continuous Glucose Monitoring
14.
J Assoc Physicians India ; 72(1): 18-21, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38736069

ABSTRACT

INTRODUCTION: The world has changed tremendously for patients suffering from diabetes mellitus with the development of cutting-edge technologies like continuous glucose monitoring and flash glucose monitoring systems. Now, the details of constant fluctuations of glucose in their blood can be monitored not only by medical professionals but also by patients, and this is called glycemic variability (GV). Traditional metrics of glycemic control measurement, such as glycated hemoglobin (HbA1c), fail to reflect various short-term glycemic changes like postprandial hyperglycemia and hypoglycemic episodes, paving the way to the occurrence of various diabetic complications even in asymptomatic, well-controlled diabetic patients. This need for advanced management of diabetes and effective monitoring of these swings in blood glucose can be met by using a continuous glucose monitoring system (CGMS). AIM AND OBJECTIVE: To evaluate the extent of GV in well-controlled type 2 diabetes mellitus (T2DM) patients using a flash CGMS and to assess the correlation between GV and HbA1c. MATERIALS AND METHODS: A hospital-based prospective observational study was carried out from May 2020 to Oct 2021 at the Department of Medicine, SMS Hospital, Jaipur, Rajasthan (India), after approval from the Ethics Committee of the institution. A total of 30 patients with well-controlled T2DM (HbA1c was ≥6.5, but ≤7.5) were included in the study using simple random techniques after written informed consent from patients. Patients were studied for glycemic excursions over a period of 7 days by using FreeStyle® Libre Pro™, which is a flash glucose monitoring system. The CGM sensor was attached to the left upper arm of the patient on day 0 and removed on day 7. The data recorded in the sensor was then retrieved using pre-installed computer software and analyzed using standard CGM metrics like standard deviation (SD), percentage coefficient of variation (%CV), time above range (TAR), time below range (TBR), and time in range (TIR), out of which %CV was used to quantify GV. %CV has been used to cluster patients into four cohorts from best to worst, namely: best/low CV ≤ 10%, intermediate CV from 10 to 20%, high CV from 20 to 30%, and very high CV of >30%. Scatterplots are used to establish correlations between various parameters. RESULT: Data from a total of 30 patients were analyzed using CGMS and thus used for calculating standard CGM metrics; glucose readings every 15 minutes were recorded consecutively for 7-day periods, making it a total of 672 readings for each patient. Interpreting the CGM data of all 30 patients, the following results were found: the mean blood glucose of all cases is 134.925 ± 22.323 mg/dL, the mean SD of blood glucose of all cases is 35.348 ± 9.388 mg/dL, the mean of %CV of all cases is 26.376 ± 6.193%. CGM parameters of time are used in the form of percentages, and the following results were found: the mean of TAR, TBR, and TIR is 14.425 ± 13.211, 5.771 ± 6.808, and 82.594 ± 12.888%, respectively. Clustering the patients into cohorts, the proportion of patients exhibiting best/low %CV (10%) is 0, intermediate %CV (10-20%) is 16.67% (five out of 30 patients), high %CV (20-30%) is 50% (15 out of 30 patients) and very high %CV (>30%) is 33.33% (10 out of 30 patients). Also, there is no significant correlation found between HbA1c and %CV (ρ = 0.076, p-value = 0.690); a significant negative correlation was found between %CV and TIR (ρ = -0.604, p < 0.001S); a positive correlation of %CV with TAR and TBR is significant (ρ = 0.816, p-value of <0.001). CONCLUSION: Using a flash CGMS device and considering %CV as the parameter and primary measure of GV, the study demonstrated the overall instability of a person's glycemic control, making note of unrecognized events of hypoglycemia and hyperglycemia in asymptomatic well-controlled T2DM patients, revealing the overall volatile glycemic control. The most important finding of this study is that even those diabetics who are considered well-controlled experience a great degree of GV as assessed by CGM-derived metrics. This study also demonstrated that there is no significant correlation between HbA1c and GV, suggesting that patients may not have optimal control of their diabetes despite having "normal HbA1c" values; hence, GV can be considered an HbA1c-independent danger factor, having more harmful effects than sustained hyperglycemia in the growth of diabetic complications. So, by using CGM-derived metrics, the measurement of GV has the potential to complement HbA1c data. In this manner, a more comprehensive assessment of glycemic excursions can be provided for better treatment decisions, thereby facilitating optimal glycemic control, which is essential for reducing overall complications and promoting good quality of life.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 2 , Glycated Hemoglobin , Humans , Diabetes Mellitus, Type 2/blood , Blood Glucose Self-Monitoring/methods , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose/analysis , Glycated Hemoglobin/analysis , Female , Male , Middle Aged , Prospective Studies , Glycemic Control/methods , Adult , Aged , Continuous Glucose Monitoring
15.
Front Endocrinol (Lausanne) ; 15: 1364585, 2024.
Article in English | MEDLINE | ID: mdl-38774225

ABSTRACT

Aim: To evaluate the efficacy and safety of URLi (ultra rapid lispro insulin) compared to insulin lispro as bolus insulin with basal insulin using CGM in the individuals with type 2 diabetes(T2D) in China. Methods: This was a double-blind, randomized, parallel, prospective, phase 3 study. Subjects with uncontrolled T2D were recruited and randomized 1:2 into the insulin lispro and URLi groups. Subjects received a consistent basal insulin regimen during the study and self-administered insulin lispro or URLi before each meal throughout the treatment period. Subjects underwent a 3-day continuous glucose monitoring (CGM) at the baseline and endpoint respectively, and then CGM data were analyzed. The primary endpoint was to compare the difference in postprandial glucose (PPG) control using CGM between the two groups. Results: A total of 57 subjects with T2D completed the study. Our CGM data showed that postprandial glucose excursions after breakfast (BPPGE) in the URLi group was lower than that in the insulin lispro group (1.59 ± 1.57 mmol/L vs 2.51 ± 1.73 mmol/L, p = 0.046). 1-hour PPG was observed to decrease more in the URLi group than that in the insulin lispro group (-1.37 ± 3.28 mmol/L vs 0.24 ± 2.58 mmol/L, p = 0.047). 2-hour PPG was observed to decrease more in the URLi group than that in the insulin lispro group (-1.12 ± 4.00 mmol/L vs 1.22 ± 2.90 mmol/L, p = 0.021). The mean HbA1c level decreased by 1.1% in the URLi group and 0.99% in the insulin lispro group, with no treatment difference (p = 0.642). In the CGM profile, TBR was not significantly different between the two groups (p = 0.743). The weight gain also did not differ between the two groups (p = 0.303). Conclusion: URLi can control breakfast PPG better than insulin lispro in adults with T2D in China, while it is non-inferior in improving HbA1c. The incidence of hypoglycemic and weight gain were similar between the two groups.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 2 , Hypoglycemic Agents , Insulin Lispro , Postprandial Period , Humans , Diabetes Mellitus, Type 2/drug therapy , Diabetes Mellitus, Type 2/blood , Insulin Lispro/therapeutic use , Insulin Lispro/administration & dosage , Male , Female , Middle Aged , Blood Glucose/analysis , China/epidemiology , Double-Blind Method , Hypoglycemic Agents/therapeutic use , Hypoglycemic Agents/administration & dosage , Blood Glucose Self-Monitoring/methods , Prospective Studies , Glycemic Control/methods , Adult , Aged , Glycated Hemoglobin/analysis , Drug Therapy, Combination
16.
Front Endocrinol (Lausanne) ; 15: 1355792, 2024.
Article in English | MEDLINE | ID: mdl-38774233

ABSTRACT

Background: Diabetes Mellitus, a global health challenge, affects 537 million individuals. Traditional management relies on periodic clinic visits, but technological advancements, including remote monitoring, offer transformative changes. Telemedicine enhances access, convenience, adherence, and glycemic control. Challenges include trust-building and limitations in face-to-face interactions. Integrating remote monitoring with in-person healthcare creates a hybrid approach. This study evaluates the impact on Type 2 Diabetes patients over 3 months. Methods: A retrospective case-control observational study. Inclusion criteria involved previous Type 2 Diabetes diagnosis and a minimum 3-month GluCare model period with two physical visits. Patients in the case group had in-clinic visits, bi-weekly app engagement, and monthly body weight readings. Control group had in-clinic visits only. Outcomes measured included HbA1c, lipid profile, CV risk, eGFR, urine Albumin/Creatinine Ratio, Uric Acid, and CRP. Results: Case group showed significant HbA1c improvements (-2.19%), especially in higher baseline levels. Weight, BMI, LDL, total cholesterol, and CVD risk also improved. Controls showed smaller improvements. Higher digital interactions correlated with better outcomes. Patients with ≥11 interactions showed significant reductions in HbA1c (-2.38%) and weight (-6.00 kg). Conclusion: The GluCare.Health hybrid model demonstrates promising outcomes in Type 2 diabetes management. The integration of in-clinic consultations with continuous remote monitoring leads to substantial improvements in glycemic control and clinical parameters. The study highlights the importance of patient engagement in achieving positive outcomes, with higher digital interactions associated with greater reductions in HbA1c and weight. The hybrid approach proves more effective than digital-only interventions, emphasizing the need for comprehensive, end-to-end solutions in diabetes care.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 2 , Telemedicine , Humans , Diabetes Mellitus, Type 2/therapy , Diabetes Mellitus, Type 2/blood , Female , Male , Middle Aged , Retrospective Studies , Case-Control Studies , Blood Glucose Self-Monitoring/methods , Blood Glucose/analysis , Blood Glucose/metabolism , Glycated Hemoglobin/analysis , Glycated Hemoglobin/metabolism , Aged , Adult
17.
Nat Med ; 30(5): 1424-1431, 2024 May.
Article in English | MEDLINE | ID: mdl-38589602

ABSTRACT

Plasma fasting glucose (FG) levels play a pivotal role in the diagnosis of prediabetes and diabetes worldwide. Here we investigated FG values using continuous glucose monitoring (CGM) devices in nondiabetic adults aged 40-70 years. FG was measured during 59,565 morning windows of 8,315 individuals (7.16 ± 3.17 days per participant). Mean FG was 96.2 ± 12.87 mg dl-1, rising by 0.234 mg dl-1 per year with age. Intraperson, day-to-day variability expressed as FG standard deviation was 7.52 ± 4.31 mg dl-1. As there are currently no CGM-based criteria for diabetes diagnosis, we analyzed the potential implications of this variability on the classification of glycemic status based on current plasma FG-based diagnostic guidelines. Among 5,328 individuals who would have been considered to have normal FG based on the first FG measurement, 40% and 3% would have been reclassified as having glucose in the prediabetes and diabetes ranges, respectively, based on sequential measurements throughout the study. Finally, we revealed associations between mean FG and various clinical measures. Our findings suggest that careful consideration is necessary when interpreting FG as substantial intraperson variability exists and highlight the potential impact of using CGM data to refine glycemic status assessment.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Fasting , Prediabetic State , Humans , Blood Glucose/analysis , Middle Aged , Fasting/blood , Adult , Male , Female , Aged , Prediabetic State/diagnosis , Prediabetic State/blood , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus/blood , Diabetes Mellitus/diagnosis , Continuous Glucose Monitoring
19.
Sci Rep ; 14(1): 9206, 2024 04 22.
Article in English | MEDLINE | ID: mdl-38649731

ABSTRACT

Periodic quantification of blood glucose levels is performed using painful, invasive methods. The proposed work presents the development of a noninvasive glucose-monitoring device with two sensors, i.e., finger and wrist bands. The sensor system was designed with a near-infrared (NIR) wavelength of 940 nm emitter and a 900-1700 nm detector. This study included 101 diabetic and non-diabetic volunteers. The obtained dataset was subjected to pre-processing, exploratory data analysis (EDA), data visualization, and integration methods. Ambiguities such as the effects of skin color, ambient light, and finger pressure on the sensor were overcome in the proposed 'niGLUC-2.0v'. niGLUC-2.0v was validated with performance metrics where accuracy of 99.02%, mean absolute error (MAE) of 0.15, mean square error (MSE) of 0.22 for finger, and accuracy of 99.96%, MAE of 0.06, MSE of 0.006 for wrist prototype with ridge regression (RR) were achieved. Bland-Altman analysis was performed, where 98% of the data points were within ± 1.96 standard deviation (SD), 100% were under zone A of the Clarke Error Grid (CEG), and statistical analysis showed p < 0.05 on evaluated accuracy. Thus, niGLUC-2.0v is suitable in the medical and personal care fields for continuous real-time blood glucose monitoring.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Humans , Blood Glucose/analysis , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , Male , Female , Adult , Fingers , Middle Aged , Wrist , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Diabetes Mellitus/blood , Diabetes Mellitus/diagnosis
20.
N Z Med J ; 137(1593): 14-30, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38603784

ABSTRACT

AIMS: To examine the impact of intensive management of type 1 diabetes (T1D) from diagnosis on HbA1c 12 months from diagnosis. METHODS: HbA1c measured 12 months after diagnosis for 70 consecutively newly diagnosed children with T1D following implementation of an intensive management protocol was compared with 70 children consecutively diagnosed immediately pre-implementation. Intensive management involved carbohydrate counting and flexible insulin dosing from first meal with subcutaneous insulin, targeted blood glucose levels from 4-8mmol/L irrespective of time of day, avoidance of twice daily insulin regimen and promotion of continuous glucose monitoring (CGM). HbA1c, diabetes technology use and insulin regimen at 12 months post-diagnosis were compared. RESULTS: The post-intensive management implementation cohort had an improved mean HbA1c of 58.2±15.3mmol/mol vs 63.7±10.7mmol/mol at 12 months (p=0.014). The proportion of young people with diabetes meeting a target HbA1c of <53mmol/mol at 12 months improved from 11% to 40% (p=<0.001). There was a reduction of twice daily insulin regimen from 66% to 11% (p=<0.001), and increased CGM use from 57% to 76% (p=0.02). CONCLUSION: Intensive management when implemented with consistent messaging from the multi-disciplinary team resulted in clinic-wide improvements in HbA1c and the proportion meeting HbA1c targets.


Subject(s)
Diabetes Mellitus, Type 1 , Child , Humans , Adolescent , Diabetes Mellitus, Type 1/diagnosis , Diabetes Mellitus, Type 1/drug therapy , Glycated Hemoglobin , Blood Glucose , Blood Glucose Self-Monitoring/methods , Prospective Studies , New Zealand , Insulin/therapeutic use , Hypoglycemic Agents/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...