Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.201
Filter
1.
Khirurgiia (Mosk) ; (5): 123-128, 2024.
Article in Russian | MEDLINE | ID: mdl-38785248

ABSTRACT

Syphilitic aortitis is a rare disease caused by Treponema pallidum affecting the aorta and leading to inflammation. Syphilitic aortitis is one of the causes of aortic aneurysms. This article presents surgical treatment of a patient with syphilitic aortitis and thoracic aortic aneurysm. This clinical case confirms the difficulties of surgical treatment.


Subject(s)
Aortic Aneurysm, Thoracic , Syphilis, Cardiovascular , Humans , Syphilis, Cardiovascular/diagnosis , Syphilis, Cardiovascular/surgery , Syphilis, Cardiovascular/complications , Male , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnosis , Treatment Outcome , Treponema pallidum/isolation & purification , Blood Vessel Prosthesis Implantation/methods , Middle Aged , Aortitis/diagnosis , Aortitis/surgery , Aortitis/microbiology
2.
J Cardiothorac Surg ; 19(1): 298, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778415

ABSTRACT

BACKGROUND: Our patient presented with acute back pain and dyspnea, without neurological symptoms. The computed tomography (CT) scan showed a circumferent rupture of the ascending aortic intima which was invaginated in the arch and descending aorta. CASE PRESENTATION: A 54-year-old male patient was diagnosed with a Type A aortic dissection. He was immediately transferred to our operation room (OR) from the emergency department of a peripheral hospital. He presented with a circumferential dissection of the ascending aorta originating just distal to the coronary ostia, with the invaginated intimal mass extending through the arch down the descending aorta. In mild hypothermia, the intimal mass was safely extracted and a frozen elephant trunk (FET) procedure was performed. CONCLUSIONS: Despite the extensive dissection affecting the ascending aorta and aortic arch, resulting in partially occluded supra-aortic vessels by an intimal mass, the patient remained without neurological symptoms in the pre- and post-operative period and remains well one year post surgery.


Subject(s)
Aortic Dissection , Humans , Male , Middle Aged , Aortic Dissection/surgery , Tomography, X-Ray Computed , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Aorta/surgery , Aorta, Thoracic/surgery , Aorta, Thoracic/diagnostic imaging
3.
Bratisl Lek Listy ; 125(6): 347-353, 2024.
Article in English | MEDLINE | ID: mdl-38757590

ABSTRACT

PURPOSE: Standard endovascular aortic aneurysm repair (EVAR) is sometimes the only treatment option for patients with hostile aortic neck anatomy, but it carries an increased risk of both early and late procedure-related complications. The aim of this study was to report on single-center experience with the Heli-FX EndoAnchors (Medtronic, Santa Rosa, CA) as an adjunctive procedure to endovascular aneurysm repair (EVAR) for prevention and perioperative treatment of proximal neck complications in patients with hostile neck anatomy.  MATERIALS AND METHODS: A single-centre, retrospective study evaluating 24 consecutive patients treated with EndoAnchors during the index EVAR procedure between November 2018 and August 2021. EndoAnchor implantation was indicated for cases with hostile proximal aortic neck anatomy characterised by the presence of at least one of the following parameters: length of 28 mm, angle of >60°, circumferential thrombus/calcification involving ≥50%, and reverse taper. RESULTS:  Median follow-up period was 22.5 months (IQR 2-31.5 months) with no aneurysm-related death, rupture, or conversion to open surgical repair during the follow-up. The procedural success rate was 100%, with no type Ia endoleak at the completion angiography. A mean of 7 EndoAnchors was used per patient (range 4-12). There were no EndoAnchor fractures and dislocations or stent graft fabric damage due to anchor implants. Twenty-three patients (95.8%) remained free of type Ia endoleak and migration on follow-up imaging. Aneurysm sac regression was observed in 13 patients (54.1%), while in 8 patients (33.3%) the sac remained stable. Sac enlargement was present in 1 patient (4.2%) due to late type Ia endoleak. Two patients were lost to the follow-up immediately after the procedure. Between two groups of patients (sac regression versus failure to regress), the larger initial diameter of the proximal neck was the only significant independent factor associated with a lower possibility of sac regression (p= 0,021). CONCLUSIONS:  The use of EndoAnchors during the index EVAR procedure in cases with challenging aortic neck anatomy with or without perioperative type Ia endoleak was associated with good midterm results and led to sac regression in most of the patients (Tab. 4, Fig. 3, Ref. 31).


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endovascular Procedures/methods , Male , Retrospective Studies , Female , Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/instrumentation , Aged, 80 and over , Postoperative Complications/prevention & control , Endoleak/etiology , Endoleak/prevention & control , Treatment Outcome , Blood Vessel Prosthesis , Stents
4.
J Cardiothorac Surg ; 19(1): 276, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38704597

ABSTRACT

BACKGROUND: Conventional graft replacement for a juxtarenal abdominal aortic aneurysm (JRAAA) remains challenging for high-risk patients since it often requires the reconstruction of some visceral arteries. CASE PRESENTATION: A 76-year-old woman was diagnosed with an 87 × 48 mm saccular JRAAA. Open graft replacement was contraindicated because of frailty and a past history of trans-thoracoabdominal esophagectomy. Chimney endovascular aortic repair (ChEVAR) with three chimney endografts was successfully performed without any endoleaks, and each visceral circulation was kept intact. The patient was discharged uneventfully on postoperative day 8. Significant shrinkage of the aneurysmal sac and preservation of flow through each chimney graft were observed on computed tomography 6 months postoperatively, with no significant increase in serum creatinine levels on laboratory testing. CONCLUSIONS: ChEVAR can be a useful surgical option instead of conventional operations, especially for high-risk cases.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Esophagectomy , Humans , Female , Aged , Aortic Aneurysm, Abdominal/surgery , Endovascular Procedures/methods , Esophagectomy/adverse effects , Esophagectomy/methods , Blood Vessel Prosthesis Implantation/methods , Tomography, X-Ray Computed , Endovascular Aneurysm Repair
5.
Zhonghua Yi Xue Za Zhi ; 104(17): 1499-1506, 2024 May 07.
Article in Chinese | MEDLINE | ID: mdl-38706057

ABSTRACT

Objective: To Compare the effects and safety of lumen reshaping after thoracic endovascular aortic repair (TEVAR) for Stanford B type aortic dissection (AD) at different intervention times. Methods: A retrospective analysis was conducted on the clinical data of 189 patients with Stanford type B aortic dissection treated with TEVAR at the Affiliated Hospital of Chengde Medical College from January 2016 to December 2020.Based on the time from onset to surgery, patients were divided into an early intervention group (≤14 days, n=127) and a delayed intervention group (>14 days, n=62).The diameters of the total aorta, true lumen and false lumen at different times and planes (S1 plane: at the bifurcation of the pulmonary artery; S2 plane: at the lower edge of the left atrium; S3 plane: at the upper edge of the celiac trunk) post-surgery were compared between the two groups, and the rate of change in diameters of true and false lumens across these planes was calculated. The patients were followed until December 1st, 2023, and the median follow-up time was 45(40, 49) months. The postoperative complications and survival of the two groups were compared. Results: The early intervention group comprised 86 men and 41 women, with an average age of (58.3±10.7) years. The delayed intervention group included 41 men and 21 women, with an average age of (58.5±9.2) years. Both groups had an operation success rate of 100%. Six months post-surgery, the early intervention group had an expansion rate of the true lumen diameter at planes S2 and S3 of 40.1%(25.5%, 56.1%) and 5.3%(-2.5%, 15.8%), respectively, which was superior to the delayed intervention group's 18.5%(10.6%, 39.8%) and 1.0%(-8.2%, 9.6%) (both P<0.05).The early intervention group had a reduction rate of the false lumen diameter at planes S1, S2, and S3 of -56.2%(-61.3%, -48.8%), -70.4%(-81.8%, -56.6%), and -5.4%(-17.4%, 0.1%), respectively, better than the delayed intervention group's -44.2%(-53.7%, -38.3%), -49.0%(-57.6%, -35.8%), and -3.1%(-6.7%, 1.8%) (all P<0.05).At plane S1, the true lumen diameter of patients in both groups showed an increasing trend over 36 months post-surgery, while the false lumen diameter showed a decreasing trend (both P<0.05).At plane S2, the true lumen diameter of patients in the early intervention group exhibited an increasing trend over 36 months post-surgery, and the false lumen diameter exhibited a decreasing trend (both P<0.05).At plane S3, the total aortic diameter of patients in the delayed intervention group showed a slight increasing trend over 36 months post-surgery (P<0.05).The overall survival time were 45.0 months (95%CI: 42.9-47.1) for patients in the early intervention group and 46.0 months (95%CI: 43.5-48.5) for those in the delayed intervention group, with no statistically significant difference observed (P>0.05).The incidence rates of complications such as aortic rupture, retrograde Type A dissection, new distal endograft dissection, endoleak, paraplegia, and others showed no statistically significant difference between the two groups (all P>0.05), with no cases of stent migration or deformation observed. Conclusion: Early intervention for Stanford type B aortic dissection provides a better aortic remodeling outcome than delayed intervention, with similar safety.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , Female , Aortic Dissection/surgery , Middle Aged , Retrospective Studies , Endovascular Procedures/methods , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Postoperative Complications , Aorta, Thoracic/surgery , Treatment Outcome , Time Factors , Aged
6.
Medicina (Kaunas) ; 60(5)2024 May 08.
Article in English | MEDLINE | ID: mdl-38792960

ABSTRACT

Background and Objectives: Lower extremity arterial disease is one of the most prevalent manifestations of atherosclerosis. The results from numerous studies regarding the best revascularization method of an occluded superficial femoral artery have been conflicting. The aim of this study was to compare the patency of transvenous endovascular with open femoropopliteal bypass, both with vein and prosthetic grafts. To our knowledge, a direct patency comparison between transvenous endovascular and open femoropopliteal bypass has not been published. This could help elucidate which method is preferable and in which cases. Materials and Methods: Patients with complex TASC-C and D SFA lesions were offered endovascular transvenous or open bypass. A total of 384 consecutive patients with PAD requiring surgical treatment were evaluated for inclusion in this study. Three-year follow-up data were collected for 52 endovascular procedures, 80 prosthetic grafts, and 44 venous bypass surgeries. Bypass patency was investigated by Duplex US every 6 months. Kaplan-Meier plots were used to analyze primary, primary-assisted, and secondary patency for endovascular transvenous, autovenous, and prosthetic bypasses. Results: Primary, primary-assisted, and secondary patency in venous group at 3 years was 70.5%, 77.3%, and 77.3%, respectively. In the endovascular transvenous group, primary, primary-assisted, and secondary patency at 3 years was 46.2%, 69.2%, and 76.9%, respectively. The lowest patency rates at 3 years were noted in the prosthetic graft group with 22.5% primary, 26.6% primary-assisted, and 28.2% secondary patency. Conclusions: The saphenous vein is the best graft to perform in above-the-knee femoropopliteal bypass. Transvenous endovascular bypass is a viable option with comparable primary-assisted and secondary patency. Primary patency is substantially lower for endovascular transvenous compared to venous bypass. Patients treated with endovascular transvenous bypass will require a significant number of secondary procedures to provide optimal patency. Prosthetic grafts should only be used if no other option for bypass is available.


Subject(s)
Endovascular Procedures , Femoral Artery , Popliteal Artery , Vascular Patency , Humans , Femoral Artery/surgery , Male , Female , Popliteal Artery/surgery , Aged , Endovascular Procedures/methods , Middle Aged , Treatment Outcome , Peripheral Arterial Disease/surgery , Aged, 80 and over , Blood Vessel Prosthesis Implantation/methods
7.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38745366

ABSTRACT

In the current endovascular era, open surgery through left posterolateral thoracotomy with moderate to deep hypothermic circulatory arrest remains an alternative for treating chronic distal arch or proximal descending aortic diseases, allowing cardiovascular surgeons to definitively repair the aorta in a single stage. When utilizing this approach, this report illustrates an alternative surgical technique for antegrade body perfusion during cooling, antegrade selective cerebral perfusion and rewarming, through a prosthetic graft on the right subclavian artery. This report shows the safety and feasibility of this technique during open distal arch and/or proximal descending aortic surgery through left posterolateral thoracotomy, after shifting the patient from a supine to the right lateral decubitus position.


Subject(s)
Aorta, Thoracic , Cerebrovascular Circulation , Subclavian Artery , Thoracotomy , Humans , Subclavian Artery/surgery , Thoracotomy/methods , Aorta, Thoracic/surgery , Cerebrovascular Circulation/physiology , Male , Perfusion/methods , Aged , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Middle Aged
8.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38759115

ABSTRACT

OBJECTIVES: The Dissected Aorta Repair Through Stent (DARTS) Implantation trial demonstrated positive proximal aortic remodelling following aortic dissection repair with the AMDS hybrid prosthesis. In this study, we look to identify predictors of aortic remodelling following aortic dissection repair with AMDS including whether communications between branch vessels and the false lumen (FL) predict aortic growth. METHODS: The DARTS implantation trial included patients who underwent acute DeBakey type I aortic dissection (ATAD I) repair with the AMDS from March 2017 to January 2019. Anatomic measurements were collected from original computerized tomography scans. Measurements were taken at zones 2, 3, 6 and 9. Patients were grouped based on the number of FL communications with the supra-aortic branch vessels or visceral branch vessels. RESULTS: Forty-seven patients were included in the original DARTS implantation trial. Patients with FL communications with the supra-aortic branch vessels tended to have significant growth at zone 3 (P = 0.02-0.0018), while greater numbers of visceral FL communications tended to predict aortic growth at zones 3 (P = 0.003), 6 (P = 0.017-0.0087) and 9 (P = 0.0016-0.0003). CONCLUSIONS: Aortic remodelling following ATAD I repair using the AMDS may be predicted by local FL communications with branch vessels. Patients undergoing ATAD I repair were more likely to experience significant aortic growth in zone 3 with more head vessel communications and in zones 3, 6 and 9 with more visceral FL communications. Predictors of aortic remodelling may help to guide initial surgical management for aortic dissection patients.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Stents , Vascular Remodeling , Humans , Aortic Dissection/surgery , Male , Female , Middle Aged , Vascular Remodeling/physiology , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Aged , Endovascular Procedures/methods , Prosthesis Design , Tomography, X-Ray Computed , Treatment Outcome
9.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38733578

ABSTRACT

OBJECTIVES: The goal of this multicentre retrospective cohort study was to evaluate technical success and early and late outcomes of thoracic endovascular repair (TEVAR) with grafts deployed upside down through antegrade access, to treat thoracic aortic diseases. METHODS: Antegrade TEVAR operations performed between January 2010 and December 2021 were collected and analysed. Both elective and urgent procedures were included. Exclusion criteria were endografts deployed in previous or concomitant surgical or endovascular repairs. RESULTS: Fourteen patients were enrolled; 13 were males (94%) with a mean age of 71 years (interquartile range 62; 78). Five patients underwent urgent procedures (2 ruptured aortas and 3 symptomatic patients). Indications for treatment were 8 (57%) aneurysms/pseudoaneurysms, 3 (21%) dissections and 3 (21%) penetrating aortic ulcers. Technical success was achieved in all procedures. Early mortality occurred in 4 (28%) cases, all urgent procedures. Median follow-up was 13 months (interquartile range 1; 44). Late deaths occurred in 2 (20%) patients, both operated on in elective settings. The first died at 19 months of aortic-related reintervention; the second died at 34 months of a non-aortic-related cause. Two patients (14%) underwent aortic-related reinterventions for late type I endoleak. The survival rate of those having the elective procedures was 100%, 84% and 67% at 12, 24 and 36 months, respectively. Freedom from reintervention was 92%, 56% and 56% at 12, 24 and 36 months, respectively. CONCLUSIONS: Antegrade TEVAR can seldom be considered an alternative when traditional retrograde approach is not feasible. Despite good technical success and few access-site complications, this study demonstrates high rates of late type I endoleak and aortic-related reinterventions.


Subject(s)
Aorta, Thoracic , Aortic Diseases , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , Endovascular Procedures/methods , Aged , Female , Retrospective Studies , Aorta, Thoracic/surgery , Middle Aged , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Treatment Outcome , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/mortality , Postoperative Complications/epidemiology , Blood Vessel Prosthesis , Endovascular Aneurysm Repair
10.
BJS Open ; 8(3)2024 May 08.
Article in English | MEDLINE | ID: mdl-38768283

ABSTRACT

BACKGROUND: Extended aortic repair is considered a key issue for the long-term durability of surgery for DeBakey type 1 aortic dissection. The risk of aortic degeneration may be higher in young patients due to their long life expectancy. The early outcome and durability of aortic surgery in these patients were investigated in the present study. METHODS: The subjects of the present analysis were patients under 60 years old who underwent surgical repair for acute DeBakey type 1 aortic dissection at 18 cardiac surgery centres across Europe between 2005 and 2021. Patients underwent ascending aortic repair or total aortic arch repair using the conventional technique or the frozen elephant trunk technique. The primary outcome was 5-year cumulative incidence of reoperation on the distal aorta. RESULTS: Overall, 915 patients underwent surgical ascending aortic repair and 284 patients underwent surgical total aortic arch repair. The frozen elephant trunk procedure was performed in 128 patients. Among 245 propensity score-matched pairs, total aortic arch repair did not decrease the rate of distal aortic reoperation compared to ascending aortic repair (5-year cumulative incidence, 6.7% versus 6.7%, subdistributional hazard ratio 1.127, 95% c.i. 0.523 to 2.427). Total aortic arch repair increased the incidence of postoperative stroke/global brain ischaemia (25.7% versus 18.4%, P = 0.050) and dialysis (19.6% versus 12.7%, P = 0.003). Five-year mortality was comparable after ascending aortic repair and total aortic arch repair (22.8% versus 27.3%, P = 0.172). CONCLUSIONS: In patients under 60 years old with DeBakey type 1 aortic dissection, total aortic arch replacement compared with ascending aortic repair did not reduce the incidence of distal aortic operations at 5 years. When feasible, ascending aortic repair for DeBakey type 1 aortic dissection is associated with satisfactory early and mid-term outcomes. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04831073.


Subject(s)
Aorta, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Postoperative Complications , Reoperation , Humans , Aortic Dissection/surgery , Aortic Dissection/mortality , Male , Female , Middle Aged , Aorta, Thoracic/surgery , Reoperation/statistics & numerical data , Postoperative Complications/epidemiology , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/mortality , Adult , Retrospective Studies , Treatment Outcome , Europe/epidemiology , Propensity Score
11.
J Cardiothorac Surg ; 19(1): 237, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627730

ABSTRACT

Redo ascending and aortic arch surgeries following previous cardiac or aortic surgery are associated with high risk of morbidity and mortality due to multiple factors included sternal re-entry injury, extensive aortic arch surgery, emergency aortic surgery, prolonged cardiopulmonary bypass duration, poor heart function, and patients with older age. Therefore, appropriate surgical strategies are important. We report a case of a 72-year-old gentleman with previous surgery of aortic root replacement who presented with acute Type A aortic dissecting aneurysm of ascending and aortic arch complicated with left hemothorax, which was successfully treated by emergency redo aortic surgery with frozen elephant trunk (FET) technique.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Male , Humans , Aged , Aorta, Thoracic/surgery , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Aortic Valve/surgery , Aortic Dissection/surgery , Retrospective Studies , Treatment Outcome , Stents
12.
Cardiovasc Intervent Radiol ; 47(5): 670-677, 2024 May.
Article in English | MEDLINE | ID: mdl-38653812

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the 5-year real-world results of Supera stent implantation in below the knee prosthetic bypasses (BKPBs). All the procedures were performed because of a history of recurrent thrombosis of the graft and significant stenotic kinking of the prosthesis during knee flexion. A Supera stent was implanted to prevent the next potential BKPB thrombosis. MATERIALS AND METHODS: Fourteen patients were included in this single-center, retrospective observational cohort study. All patients underwent Supera stent implantation in infrainguinal prosthetic bypass between 2012 and 2017, due to a history of recurrent thrombosis and kinking of the prosthetic bypass. RESULTS: Prior to Supera stent implantation procedure, all the patients had more than one episode of acute limb ischemia caused by thrombosis of the BKPB. The median number of BKPB thromboses prior to Supera stent implantation was 3 and ranged from 2 to 6. Technical success was achieved in all cases. Primary patency rates at 12, 24, 36 and 60 months were 71.4%, 57.1%, 57.1% and 14.3%, respectively. Secondary patency rates at 12, 24, 36 and 60 months were 78.6%, 64.3%, 64.3% and 35.7%, respectively. One stent fracture was reported during 60-month follow-up. Major amputation was performed in 6 patients in 5-year follow-up. CONCLUSION: Supera stent in treatment of recurrent thrombosis of BKBP is a safe procedure with acceptable mid-term results. However, larger and comparable prospective studies are needed for broader analysis of this procedure.


Subject(s)
Graft Occlusion, Vascular , Stents , Humans , Male , Retrospective Studies , Female , Aged , Middle Aged , Thrombosis/etiology , Aged, 80 and over , Vascular Patency , Treatment Outcome , Blood Vessel Prosthesis Implantation/methods
13.
Catheter Cardiovasc Interv ; 103(6): 982-994, 2024 May.
Article in English | MEDLINE | ID: mdl-38584518

ABSTRACT

Endovascular aortic repair is an emerging novel intervention for the management of abdominal aortic aneurysms. It is crucial to compare the effectiveness of different access sites, such as transfemoral access (TFA) and upper extremity access (UEA). An electronic literature search was conducted using PubMed, EMBASE, and Google Scholar databases. The primary endpoint was the incidence of stroke/transient ischemic attack (TIA), while the secondary endpoints included technical success, access-site complications, mortality, myocardial infarction (MI), spinal cord ischemia, among others. Forest plots were constructed for the pooled analysis of data using the random-effects model in Review Manager, version 5.4. Statistical significance was set at p < 0.05. Our findings in 9403 study participants (6228 in the TFA group and 3175 in the UEA group) indicate that TFA is associated with a lower risk of stroke/TIA [RR: 0.55; 95% CI: 0.40-0.75; p = 0.0002], MI [RR: 0.51; 95% CI: 0.38-0.69; p < 0.0001], spinal cord ischemia [RR: 0.41; 95% CI: 0.32-0.53, p < 0.00001], and shortens fluoroscopy time [SMD: -0.62; 95% CI: -1.00 to -0.24; p = 0.001]. Moreover, TFA required less contrast agent [SMD: -0.33; 95% CI: -0.61 to -0.06; p = 0.02], contributing to its appeal. However, no significant differences emerged in technical success [p = 0.23], 30-day mortality [p = 0.48], ICU stay duration [p = 0.09], or overall hospital stay length [p = 0.22]. Patients with TFA had a lower risk of stroke, MI, and spinal cord ischemia, shorter fluoroscopy time, and lower use of contrast agents. Future large-scale randomized controlled trials are warranted to confirm and strengthen these findings.


Subject(s)
Blood Vessel Prosthesis Implantation , Catheterization, Peripheral , Endovascular Aneurysm Repair , Femoral Artery , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis Implantation/methods , Catheterization, Peripheral/methods , Endovascular Aneurysm Repair/methods , Femoral Artery/diagnostic imaging , Pilot Projects , Punctures , Risk Assessment , Risk Factors , Stroke/etiology , Stroke/mortality , Stroke/prevention & control , Time Factors , Treatment Outcome , Upper Extremity/blood supply
14.
J Cardiothorac Surg ; 19(1): 199, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38600502

ABSTRACT

BACKGROUND: Total endovascular technique with fenestrated endovascular graft might be hampered for the late dilatation of proximal landing zone, which may cause endografts migration. We describe a successful urgent hybrid procedure for extent III thoracoabdominal aortic aneurysm with aortic intramural hematoma. CASE PRESENTATION: A 55-year-old female with thoracoabdominal aortic aneurysm was considered at high surgical risk and unfit for open repair due to multiple comorbidities. Therefore, a hybrid procedure of surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted Transaortic epicardial fixation of endograft was finally chosen and performed in the endovascular operating room. A 3-port technique was performed through a left video-assisted thoracoscopic approach. After the first tampering stent-graft was deployed, a double-needle suture was penetrated both the aortic wall and stent-graft to fixate it in the proximal descending aorta. Then the second endograft, which had been fenestrated on table, was introduced and oriented extracorporeally by rotating superior mesenteric artery and left renal artery fenestration radiopaque markers and deployed with perfect apposition between the fenestrations and target visceral artery. Each vessel was sequentially stented using Viabahn self-expandable stent to finish target vessel stenting. An Ankura cuff stent was deployed in the distal abdominal aortic artery. CONCLUSION: Surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted fixation may be an innovative and viable alternative for selected high-risk patients with extent III thoracoabdominal aortic aneurysm. A longer follow-up is needed to ascertain the success of this approach.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Surgeons , Female , Humans , Middle Aged , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Thoracoscopes , Treatment Outcome , Stents , Endovascular Procedures/methods , Prosthesis Design , Aortic Aneurysm, Abdominal/surgery
15.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38676575

ABSTRACT

OBJECTIVES: Conventional treatment for type A aortic dissection includes replacement of the ascending aorta with an open distal anastomosis in the hemiarch position. The frozen elephant trunk (FET) is a hybrid technique that extends the repair to the descending thoracic aorta. The goal is to improve resolution of malperfusion syndrome and to induce positive aortic remodelling and reduce the need for reintervention on the downstream aorta. We aim to summarize the data on the short and long-term outcomes of this technique. METHODS: A thorough search of the literature was conducted isolating all articles dealing with aortic remodelling after the use of FET in case of type A acute aortic dissection. Keywords 'aortic dissection', 'frozen elephant trunk', 'aortic remodelling' and 'false lumen thrombosis' were used. Data for type B and chronic aortic dissections were excluded. RESULTS: FET use favourably influences aortic remodelling. The main advantages lie in the exclusion of distal entry tears in either the aortic arch or descending aorta thus restoring antegrade blood flow in the true lumen and inducing false lumen thrombosis. False lumen thrombosis is not only induced at the level of the stent deployment but also lower in the distal descending aorta. Moreover, it offers an adequate landing zone in the mid-descending aorta for second-stage endovascular or open surgical aortic repair, if needed. CONCLUSIONS: FET can be advantageous in the treatment of acute type A aortic dissection dealing with extended aortic pathology.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Acute Disease , Blood Vessel Prosthesis , Aorta, Thoracic/surgery , Endovascular Procedures/methods , Stents , Treatment Outcome
16.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38598445

ABSTRACT

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Subject(s)
Aortic Dissection , Blood Vessel Prosthesis Implantation , Stents , Humans , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Acute Disease , Prosthesis Design , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Aortic Aneurysm/surgery
17.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38597899

ABSTRACT

OBJECTIVES: Our goal was to review our surgical experiences in patients with complex pathologies of the aortic arch who have undergone anterolateral thoracotomy with a partial sternotomy (ALPS). METHODS: From October 2019 to November 2023, a total of 23 patients underwent one-stage repairs of complex pathologies of the aortic arch through the ALPS approach. The mean age was 61.9 ± 16.7 years old. The aortic pathologies were as follows: aorta-related infection in 11 (aorto-oesophageal fistula: 4, graft infection: 6, native aortic infection: 1); aortic dissection in 9 including shaggy aorta in 2, non-dissecting aneurysm in 1, and coarctation of the aorta (CoA) in 2. RESULTS: Eighteen patients underwent aortic replacement from either the sinotubular junction or the ascending aorta to the descending aorta; 1 patient underwent it from the aortic root to the descending aorta (redo Bentall procedure and extensive aortic arch replacement); 3 patients underwent it from the aortic arch between the left carotid artery and left subclavian artery to the descending aorta; and 1 patient underwent a descending aortic replacement. Ten patients underwent omentopexy, latissimus dorsi muscle flap installation or both procedures. The hospital mortality rate was 13.0% (3/23). The overall survival and freedom from aortic events were 73.3%±10.2% and 74.1%±10.2%, respectively, at the 3-year follow-up. There was an absence of aorta-related deaths, and no recurrent infections were identified. CONCLUSIONS: The short-term outcomes using the ALPS approach for the treatment of complex pathologies of the aortic arch were acceptable. Further studies will be required to determine the long-term results.


Subject(s)
Aorta, Thoracic , Sternotomy , Thoracotomy , Humans , Thoracotomy/methods , Aorta, Thoracic/surgery , Middle Aged , Male , Sternotomy/methods , Female , Aged , Retrospective Studies , Aortic Diseases/surgery , Adult , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Feasibility Studies , Treatment Outcome
18.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38603631

ABSTRACT

When neither surgical valve replacement nor transcatheter aortic valve implantation is possible, performing an apico-aortic conduit remains a therapeutic option. This procedure has become rare and the rigid angled apical connectors usually used to facilitate ventricular anastomosis are no longer commercially available. We described the technique that we performed on a 60-year-old patient with readily available material.


Subject(s)
Aortic Valve , Humans , Middle Aged , Aortic Valve/surgery , Male , Aorta/surgery , Aortic Valve Stenosis/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/instrumentation
20.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579061

ABSTRACT

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Male , Humans , Aged , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Axilla/surgery , Leg/surgery , Endovascular Procedures/methods , Stents , Treatment Outcome , Iliac Aneurysm/surgery
SELECTION OF CITATIONS