ABSTRACT
AIMS: Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI). METHODS AND RESULTS: We collected 30 day procedural safety data in five US centres for consecutive patients undergoing FIRM plus PVI (FIRM-PVI) compared with contemporaneous controls undergoing PVI without FIRM. A total of 625 cases were included in this analysis: 325 FIRM-PVI and 300 PVI-controls. FIRM-PVI patients were more likely than PVI-controls to be male (83% vs. 66%, P < 0.001) and have long-standing persistent AF (26% vs. 13%, P < 0.001) reflecting patients referred for FIRM. Total ablation time was greater for FIRM-PVI (62 ± 22 min) vs. PVI-controls (52 ± 18 min, P = 0.03). The complication rate for FIRM-PVI procedures (4.3%) was similar to controls (4.0%, P = 1) for both major and minor complications; no deaths were reported. The rate of complications potentially attributable to the basket catheter was small and did not differ between basket types (Constellation 2.8% vs. FIRMap 1.8%, P = 0.7) or between cases in which basket catheters were and were not used (P = 0.5). Complication rates did not differ between centres (P = 0.6). CONCLUSIONS: Procedural complications from the use of the basket catheters for AF mapping are low, and thus procedural safety appears similar between FIRM-PVI and PVI-controls in a large multicentre cohort. Future studies are required to determine the optimal approach to maximize the efficacy of FIRM-guided ablation.
Subject(s)
Atrial Fibrillation/mortality , Atrial Fibrillation/surgery , Body Surface Potential Mapping/mortality , Catheter Ablation/mortality , Catheter Ablation/statistics & numerical data , Postoperative Complications/mortality , Surgery, Computer-Assisted/mortality , Atrial Fibrillation/diagnostic imaging , Body Surface Potential Mapping/methods , Body Surface Potential Mapping/statistics & numerical data , Catheter Ablation/methods , Cohort Studies , Female , Humans , Male , Middle Aged , Postoperative Complications/prevention & control , Prevalence , Risk Factors , Surgery, Computer-Assisted/methods , Surgery, Computer-Assisted/statistics & numerical data , Survival Rate , Treatment Outcome , United States/epidemiologyABSTRACT
AIMS: This investigation addresses procedural characteristics of catheter ablation in patients with atrial fibrillation (AF) and sinus bradycardia. METHODS: From the prospective, multi-center German Ablation Registry 1073 patients with sinus rhythm at the time of AF ablation were divided into two groups according to heart rate at start of procedure (A, <60 beats per minute (bpm), n=197; B, 60-99bpm, n=876). RESULTS: Acute procedural success was high (≥98%) and similar between groups. Procedure duration and energy application time were increased in group A (180min vs. 155min and 2561s vs. 1879s, respectively). Major complications were more frequent in group A (2.2% vs. 0.5%), and a greater proportion of these patients was discharged under antiarrhythmic medication (64% vs. 52%). CONCLUSION: Catheter ablation of AF with concomitant sinus bradycardia is associated with high procedural efficacy, longer procedure- and energy application durations, and a slightly elevated complication rate.