Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 13.371
Filter
1.
Sci Rep ; 14(1): 10322, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710745

ABSTRACT

Blade cut-out is a common complication when using proximal femoral nail anti-rotation (PFNA) for the treatment of intertrochanteric fractures. Although cement augmentation has been introduced to overcome the cut-out effect, the micromechanics of this approach remain to be clarified. While previous studies have developed finite element (FE) models based on lab-prepared or cadaveric samples to study the cement-trabeculae interface, their demanding nature and inherent disadvantages limit their application. The aim of this study was to develop a novel 'one-step forming' method for creating a cement-trabeculae interface FE model to investigate its micromechanics in relation to PFNA with cement augmentation. A human femoral head was scanned using micro-computed tomography, and four volume of interest (VOI) trabeculae were segmented. The VOI trabeculae were enclosed within a box to represent the encapsulated region of bone cement using ANSYS software. Tetrahedral meshing was performed with Hypermesh software based on Boolean operation. Finally, four cement-trabeculae interface FE models comprising four interdigitated depths and five FE models comprising different volume fraction were established after element removal. The effects of friction contact, frictionless contact, and bond contact properties between the bone and cement were identified. The maximum micromotion and stress in the interdigitated and loading bones were quantified and compared between the pre- and post-augmentation situations. The differences in micromotion and stress with the three contact methods were minimal. Micromotion and stress decreased as the interdigitation depth increased. Stress in the proximal interdigitated bone showed a correlation with the bone volume fraction (R2 = 0.70); both micromotion (R2 = 0.61) and stress (R2 = 0.93) at the most proximal loading region exhibited a similar correlation tendency. When comparing the post- and pre-augmentation situations, micromotion reduction in the interdigitated bone was more effective than stress reduction, particularly near the cement border. The cementation resulted in a significant reduction in micromotion within the loading bone, while the decrease in stress was minimal. Noticeable gradients of displacement and stress reduction can be observed in models with lower bone volume fraction (BV/TV). In summary, cement augmentation is more effective at reducing micromotion rather than stress. Furthermore, the reinforcing impact of bone cement is particularly prominent in cases with a low BV/TV. The utilization of bone cement may contribute to the stabilization of trabecular bone and PFNA primarily by constraining micromotion and partially shielding stress.


Subject(s)
Bone Cements , Bone Nails , Finite Element Analysis , Hip Fractures , Humans , Hip Fractures/surgery , X-Ray Microtomography , Biomechanical Phenomena , Femur Head , Rotation
2.
Cir Cir ; 92(2): 211-218, 2024.
Article in English | MEDLINE | ID: mdl-38782385

ABSTRACT

OBJECTIVES: The aim of the study was to investigate the clinical effect of stainless-steel wire fixation on the early mouth-opening movement of an intracapsular fracture involving the condylar process. MATERIALS AND METHODS: In this study, patients who underwent mandibular condylar intracapsular fracture surgery in our hospital from 2012 to 2020 were selected as research subjects. A total of 44 patients received steel wire internal fixation treatment, 32 patients received titanium plate-and-nail rigid internal fixation, and 28 patients underwent conservative non-surgical treatment. RESULTS: For the patients in the stainless-steel wire group, the degree of mouth opening reached normal levels of 3.7 cm approximately 10 days after surgery. The recovery time for the patients in the titanium plate-and-nail rigid internal-fixation group was 21 days, while the patients in the conservative treatment group needed 60 days to recover. CONCLUSION: The treatment of fixation with a stainless-steel wire for intracapsular condylar fracture reduced the time taken to perform mouth-opening exercises and improved the recovery rate of patients.


OBJETIVO: Explorar el efecto clínico de la fijación de alambre de acero inoxidable en el movimiento temprano de apertura de la boca en la fractura interna del cóndilo. MÉTODO: Este estudio seleccionó a pacientes que se sometieron a cirugía de fractura intracapsular de cóndilo en nuestro hospital de 2012 a 2020 como sujetos de investigación. Un total de 44 pacientes recibieron tratamiento de fijación interna de alambre de acero, 32 recibieron placa de titanio y fijación interna con clavos, y 28 recibieron tratamiento conservador no quirúrgico. RESULTADOS: En los pacientes del grupo de alambre de acero inoxidable, alrededor de 10 días después de la cirugía el grado de apertura de la boca alcanzó un valor normal de 3.7 cm. El tiempo de recuperación de los pacientes en el grupo de fijación interna con clavos y placa de titanio fue de 21 días, mientras que los pacientes en el grupo de tratamiento conservador tardaron 60 días en recuperarse. CONCLUSIONES: La fijación con alambre de acero inoxidable para el tratamiento de la fractura intracapsular del cóndilo acorta el tiempo hasta la apertura de la boca y mejora la tasa de recuperación de los pacientes.


Subject(s)
Bone Plates , Bone Wires , Fracture Fixation, Internal , Mandibular Condyle , Mandibular Fractures , Stainless Steel , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Mandibular Fractures/surgery , Mandibular Condyle/injuries , Mandibular Condyle/surgery , Male , Female , Adult , Middle Aged , Titanium , Range of Motion, Articular , Bone Nails , Young Adult , Retrospective Studies
3.
Sci Rep ; 14(1): 11129, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38750240

ABSTRACT

Elastic stable intramedullary nailing (ESIN) internal fixation is used clinically to treat pathological fractures of bone cysts in children. However, one of the most important complications was removal difficulty. In this study, we aim to analyse the factors which can influence ESIN removal in healed bone cysts in children. From April 2014 to November 2020, the clinical data of 49 children who underwent elastic stable intramedullary nail removal for pathological fractures of the bone cysts in our hospital were retrospectively analysed. The following data, including age, sex, pathological fracture site, with bone graft, number of ESINs, ESIN indwelling time, and extraosseous length of ESIN were collected, and univariate analysis and logistic regression analysis was performed. The frequency of difficulty in ESIN extraction was 44.90% (22/49). The univariate logistic regression analysis showed that age,ESIN indwelling time,with bone garft and extraosseous length of ESIN may be correlated with the difficulty in removing ESIN (P < 0.05), while sex, pathological fracture site, number of ESIN may not be correlated with the difficulty in removing ESIN (P > 0.05).The multivariate logistic regression analysis showed that the ESIN indwelling time was the independent influencing factor for difficulty in removing ESIN (P < 0.05). The factors influencing the ESIN removal in healed bone cysts in children include over 11.79 years old, the long indwelling time of the ESIN(over 10.5 months),with bone graft and short extraosseous length of ESIN(≤ 0.405 cm). These factors influencing ESIN removal in healed bone cysts in children should be considered.


Subject(s)
Bone Cysts , Fracture Fixation, Intramedullary , Humans , Female , Male , Child , Bone Cysts/surgery , Fracture Fixation, Intramedullary/methods , Retrospective Studies , Child, Preschool , Adolescent , Bone Nails , Fractures, Spontaneous/surgery , Fractures, Spontaneous/etiology , Fracture Healing
4.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 613-617, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752250

ABSTRACT

Objective: To summarize the research progress in the treatment of distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children and to provide reference for clinical practice. Methods: The characteristics and treatment methods of transverse and comminuted DHMDJ fractures in children were summarized and analyzed by referring to relevant literature at home and abroad. Results: DHMDJ fractures in children are not uncommon clinically, with high fracture line position, multi-directional instability, difficult closed reduction in treatment, and easy to cause complications such as coronal and sagittal deformity of the elbow. The Kirschner wire technique was effective for DHMDJ fractures with the fracture line at the middle and low levels, but was prone to iatrogenic ulnar nerve injury. Elastic stable intramedullary nail is suitable for higher-position transverse DHMDJ fractures. However, this technique requires a second operation to remove the internal fixator, and may cause iatrogenic epiphysis plate injury in children. External fixator is a new way to treat DHMDJ fractures, and it can show satisfactory results for transverse and comminuted DHMDJ fractures. However, at present, there are few relevant studies, and most of them focus on biomechanical studies, and the efficacy lacks high-quality clinical research support. Conclusion: The ultimate goal of DHMDJ fracture treatment in children is to restore the anatomical alignment of the fracture and prevent the loss of reduction. The choice of internal fixator depends on the location of the fracture line and the shape of the fracture to provide personalized treatment.


Subject(s)
Fracture Fixation, Internal , Humeral Fractures , Humans , Child , Humeral Fractures/surgery , Fracture Fixation, Internal/methods , Bone Wires , External Fixators , Diaphyses/injuries , Fractures, Comminuted/surgery , Fracture Fixation, Intramedullary/methods , Treatment Outcome , Bone Plates , Bone Nails , Internal Fixators , Child, Preschool , Elbow Joint/surgery , Fracture Healing
5.
Eur Rev Med Pharmacol Sci ; 28(8): 3165-3175, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708475

ABSTRACT

OBJECTIVE: Periprosthetic fractures following total knee replacement are rare but challenging. The goal of the treatment is to achieve the most stable fixation that allows early mobilization. Therefore, the aim of this study was to evaluate the biomechanical results of the use of different fixation systems in the treatment of distal femur periprosthetic fractures with finite element analysis. MATERIALS AND METHODS: A total knee prosthesis was implanted in Sawbone femur models. A transverse fracture line was created in the supracondylar region and was fixed in four different groups. In group 1, fracture line fixation was fixed using retrograde intramedullary nailing. In group 2, fixation was applied using a lateral anatomic distal femoral. In group 3, in addition to the fixation made in group 1, a lateral anatomic distal femoral plate was used. In group 4, in addition to the fixation made in group 2, a 3.5 mm Limited Contact Dynamic Compression Plate (LC-DCP) was applied medially. Computed Tomography (CT) scans were taken of the created models and were converted to three-dimensional models. Axial and rotational loading forces were applied to all the created models. RESULTS: The least deformation with axial loading was observed in the double plate group. Group 3 was determined to be more advantageous against rotational forces. The greatest movement in the fracture line was found in group 2. The application of the medial plate was determined to reduce the tension on the lateral plate and increase stability in the fracture line. CONCLUSIONS: Combining a lateral anatomic plate with intramedullary nailing or a medial plate was seen to be biomechanically more advantageous than using a lateral plate or intramedullary nailing alone in the treatment of distal femoral periprosthetic fractures.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Nails , Bone Plates , Femoral Fractures , Finite Element Analysis , Fracture Fixation, Intramedullary , Periprosthetic Fractures , Arthroplasty, Replacement, Knee/adverse effects , Femoral Fractures/surgery , Humans , Periprosthetic Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Bone Screws , Biomechanical Phenomena
6.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38792901

ABSTRACT

Background and Objectives: This retrospective cohort study analyzes mechanical complications in hip fracture surgery using the Trochanteric Fixation Nail-Advanced (TFNA) implant. It investigates the correlation of these complications with demographic, intraoperative, and radiological factors, aiming to identify associated risk factors and suggest improvements in clinical surveillance and treatment strategies. Materials and Methods: We enrolled 253 patients diagnosed with pertrochanteric hip fractures treated between 2017 and 2021, with 126 meeting the criteria for a minimum 6-month follow-up. Data on demographics, American Anesthesia Association Classification (ASA), comorbidities, AO/OTA [AO (Arbeitsgemeinschaft für Osteosynthesefragen)/OTA (Orthopedic Trauma Association)] fracture classification, procedural details, and time to failure were collected. Radiographs were evaluated for reduction quality, the tip-apex distance (TAD), progressive varus deviation, and identification of mechanical complications. Statistical analysis was performed using SPSS software. Results: The predominant AO/OTA fracture classification was 31A2 in 67 cases (52.7%). Reduction quality was deemed good or acceptable in 123 cases (97.6%). The mean time to failure was 4.5 months (range: 2.2-6). The average TAD was 18 mm (range: 1.2-36), with a mean progressive varus deviation of 2.44° (range: 1.30-4.14). A good or acceptable reduction quality was observed in 97.6% of cases. Mechanical complications occurred in 21.4% of patients, with significant associations found with the lateral cortex fracture, use of a TFNA implant with a 130° angle, open reduction, and absence of prior osteoporosis treatment. Conclusions: The study provides insights into mechanical complications in proximal femur fractures treated with the TFNA nail, emphasizing the need for enhanced clinical and radiographic surveillance, especially in patients without osteoporosis treatment. Our findings support the necessity for further clinical studies comparing these outcomes with other implant designs and underscore the importance of personalized treatment strategies to reduce complication rates.


Subject(s)
Fracture Fixation, Intramedullary , Postoperative Complications , Humans , Retrospective Studies , Female , Male , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/instrumentation , Aged , Aged, 80 and over , Middle Aged , Postoperative Complications/etiology , Hip Fractures/surgery , Bone Nails , Cohort Studies , Femoral Fractures/surgery , Risk Factors , Proximal Femoral Fractures
7.
J Robot Surg ; 18(1): 221, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38780662

ABSTRACT

Intramedullary nail fixation of intertrochanteric fractures assisted by orthopedic surgical robot navigation is a new surgical method, but there are few studies comparing its efficacy with traditional intramedullary nail fixation. We aimed to assess whether robot-assisted internal fixation confers certain surgical advantages through a literature review. PubMed, EMBASE, Cochrane Library, China National Knowledge Infrastructure (CNKI) and Wan fang Data Knowledge service Platform were searched to collect randomized and non-randomized studies on patients with calcaneal fractures. Five studies were identified to compare the clinical indexes. For the clinical indexes, the technology of robot-assisted is generally feasible, in time to operation, intraoperative fluoroscopy times, blood loss, pine insertion, tip apex distance (TAD), and Harris score (P < 0.05). However, on the complication and excellent and good rate after operation did not show good efficacy compared with the traditional group (P > 0.05). Based on the current evidence, For the short-term clinical index, the advantages of robot-assisted are clear. The long-term clinical effects of the two methods are also good, but the robot-assisted shows better. However, the quality of some studies is low, and more high-quality randomized controlled trials (RCTs) are needed for further verification.


Subject(s)
Fracture Fixation, Intramedullary , Hip Fractures , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Hip Fractures/surgery , Fracture Fixation, Intramedullary/methods , Treatment Outcome , Operative Time , Blood Loss, Surgical/statistics & numerical data , Bone Nails
8.
BMC Musculoskelet Disord ; 25(1): 405, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38783225

ABSTRACT

Femoral head varus is an important complication in intertrochanteric fracture patients treated with proximal femoral nail anti-rotation (PFNA) fixation. Theoretically, extending the length of the intramedullary nail could optimize fixation stability by lengthening the force arm. However, whether extending the nail length can optimize patient prognosis is unclear. In this study, a review of imaging data from intertrochanteric fracture patients with PFNA fixation was performed, and the length of the intramedullary nail in the femoral trunk and the distance between the lesser trochanter and the distal locking screw were measured. The femoral neck varus status was judged at the 6-month follow-up. The correlation coefficients between nail length and femoral neck varus angle were computed, and linear regression analysis was used to determine whether a change in nail length was an independent risk factor for femoral neck varus. Moreover, the biomechanical effects of different nail lengths on PFNA fixation stability and local stress distribution have also been verified by numerical mechanical simulations. Clinical review revealed that changes in nail length were not significantly correlated with femoral head varus and were also not an independent risk factor for this complication. In addition, only slight biomechanical changes can be observed in the numerical simulation results. Therefore, commonly used intramedullary nails should be able to meet the needs of PFNA-fixed patients, and additional procedures for longer nail insertion may be unnecessary.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary , Hip Fractures , Humans , Biomechanical Phenomena/physiology , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Female , Male , Aged , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Femur Head/surgery , Femur Head/diagnostic imaging , Aged, 80 and over , Risk Factors , Middle Aged , Computer Simulation
9.
Jt Dis Relat Surg ; 35(2): 276-284, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727105

ABSTRACT

OBJECTIVES: This study aimed to compare the efficacy and safety of the intramedullary nail and conventional plate for the treatment of displaced intra-articular calcaneal fractures from clinical comparative trials. MATERIALS AND METHODS: A comprehensive search of English databases was carried out in the Springer, PubMed, ScienceDirect, Web of Science, and Cochrane Library databases until September 2023. Studies on calcaneal fractures treated by an intramedullary nail or a plate were considered for inclusion. Endpoints included duration of operation, length of hospital stay, the Visual Analog Scale (VAS) score, postoperative functional score, radiological parameters, and complications. The mean difference (MD) and risk difference (RD) as the combined variables, as well as the 95% confidence intervals, (CIs) were calculated. RESULTS: Five retrospective controlled studies covering 473 feet at the one-year follow-up met the inclusion criteria. The meta-analysis demonstrated that there were significant differences in the duration of operation (MD: -10.81; 95% CI: -16.32, -5.31; p=0.0001), length of hospital stay (MD: -3.65; 95% CI: -4.35, -2.95; p<0.00001). No significant differences were found regarding postoperative American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale (MD: 0.36; 95% CI: -3.89, 4.61; p=0.87), VAS (MD: 1.95; 95% CI: -0.30, 4.21; p=0.09), or postoperative Böhler angle (MD: 0.94; 95% CI: -0.04, 1.92; p=0.06) between the two groups. The incidence of total complications (RD: -0.31; 95% CI: -0.46, -0.17; p<0.0001) and wound-healing complications (RD: -0.16; 95% CI: -0.30, -0.03; p=0.02) were lower in the intramedullary nail group. There were no significant differences in the incidences of revision surgery, implant removal, superficial wound infection, deep infection, and nonunion. CONCLUSION: Compared to conventional plates, the intramedullary nail showed a shorter duration of operation, reduced length of hospital stay, and fewer postoperative total complications and wound-healing complications in treating displaced intra-articular calcaneal fractures.


Subject(s)
Bone Nails , Bone Plates , Calcaneus , Fracture Fixation, Intramedullary , Humans , Calcaneus/injuries , Calcaneus/surgery , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/adverse effects , Intra-Articular Fractures/surgery , Length of Stay , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome
10.
BMC Musculoskelet Disord ; 25(1): 389, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762453

ABSTRACT

BACKGROUND: Several methods have been used for the treatment of pediatric distal femoral fractures, such as elastic stable intramedullary nail (ESIN), external fixator (EF) and plate osteosynthesis, but there has been no consensus about the optimal method. The purpose of this study was to compare the clinical outcome between EF and ESIN techniques used in metaphyseal-diaphyseal junction (MDJ) fractures of the pediatric distal femur. METHODS: We retrospectively analyzed operatively treated MDJ fractures of pediatric distal femur between January 2015 and January 2022. Patient charts were reviewed for demographics, injury and data of radiography. All of the patients were divided into EF and ESIN groups according to the operation techniques. Malalignment was defined as more than 5 degrees of angular deformity in either plane. Clinical outcomes were measured by Flynn scoring system. RESULTS: Thirty-eight patients were included in this study, among which, 23 were treated with EF, and 15 with ESIN. The mean follow-up time was 18 months (12-24 months). At the final follow-up, all of the fractures were healed. Although there were no statistical differences between the two groups in demographic data, length of stay, estimated blood loss (EBL), rate of open reduction, time to fracture healing and Flynn score, the EF was superior to ESIN in operative time, fluoroscopic exposure and time to partial weight-bearing. The EF group had a significantly higher rate of skin irritation, while the ESIN had a significantly higher rate of malalignment. CONCLUSION: EF and ESIN are both effective methods in the treatment of MDJ fractures of the pediatric distal femur. ESIN is associated with lower rates of skin irritation. However, EF technique has the advantages of shorter operative time, reduced fluoroscopic exposure, and shorter time to partial weight-bearing, as well as lower incidence of malalignment. LEVEL OF EVIDENCE: Level III.


Subject(s)
Bone Nails , External Fixators , Femoral Fractures , Fracture Fixation, Intramedullary , Humans , Female , Male , Retrospective Studies , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Child , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Treatment Outcome , Case-Control Studies , Fracture Healing , Diaphyses/injuries , Diaphyses/surgery , Diaphyses/diagnostic imaging , Child, Preschool , Follow-Up Studies , Adolescent , Femur/surgery , Femur/diagnostic imaging
11.
BMC Musculoskelet Disord ; 25(1): 290, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622692

ABSTRACT

BACKGROUND: The proximal femoral nail anti-rotation (PFNA) with cement enhancement enhances the anchorage ability of internal fixation in elderly with osteoporotic intertrochanteric fracture. However, whether it is superior to hemiarthroplasty is still controversial. The present study aimed to determine which treatment has better clinical outcomes among older patients. METHODS: We retrospectively analyzed 102 elderly patients with osteoporosis who developed intertrochanteric fractures and underwent PFNA combined with cement-enhanced internal fixation (n = 52, CE group), and hemiarthroplasty (n = 50, HA group) from September 2012 to October 2018. All the intertrochanteric fractures were classified according to the AO/OTA classification. Additionally, the operative time, intraoperative blood loss, intraoperative and postoperative blood transfusion rates, postoperative weight-bearing time, hospitalization time, Barthel Index of Activities Daily Living, Harris score of hip function, visual analog (VAS) pain score, and postoperative complications were compared between the two groups. RESULTS: The CE group had significantly shorter operative time, lesser intraoperative blood loss, lower blood transfusion rate, and longer postoperative weight-bearing time than the HA group. The CE group had lower Barthel's Index of Activities of Daily Living, lower Harris' score, and higher VAS scores in the first and third months after surgery than the HA group, but no difference was observed between the two groups from 6 months to 12 months. There was no significant difference in the total post-operative complications between the two groups. CONCLUSION: The use of PFNA combined with a cement-enhanced internal fixation technique led to shorter operative time and lesser intraoperative blood loss and trauma in elderly patients as compared to HA.


Subject(s)
Fracture Fixation, Intramedullary , Hemiarthroplasty , Hip Fractures , Humans , Aged , Retrospective Studies , Bone Nails , Hemiarthroplasty/adverse effects , Hemiarthroplasty/methods , Blood Loss, Surgical/prevention & control , Activities of Daily Living , Treatment Outcome , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Bone Cements/therapeutic use , Postoperative Complications/surgery , Fracture Fixation, Intramedullary/adverse effects
12.
J Orthop Traumatol ; 25(1): 23, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38653863

ABSTRACT

BACKGROUND: The exact positioning of the cephalomedullary (CM) nail entry point for managing femoral fractures remains debatable, with significant implications for fracture reduction and postoperative complications. This study aimed to explore the variability in the selection of the entry point among trauma surgeons, hypothesizing potential differences and their association with surgeon experience. METHODS: In this prospective multicenter study, 16 participants, ranging from residents to senior specialists, partook in a simulation wherein they determined the optimal entry point for the implantation of a proximal femoral nail antirotation (PFN-A; DePuy Synthes) in various femora. The inter- and intra-observer variability was calculated, along with comprehensive descriptive statistical analysis, to assess the variability in entry point selection and the impact of surgeon experience. RESULTS: In this study, the mean distance from the selected entry points to the calculated mean entry point was 3.98 mm, with a smaller distance observed among surgeons with more than 500 implantations (ANOVA, p = 0.050). Intra-surgeon variability for identical femora averaged at 5.14 mm, showing no significant differences across various levels of surgical experience or training. Notably, 13.6% of selected entry points would not allow a proper intramedullary positioning of the implant, thereby rendering anatomical repositioning unfeasible. Among these impossible entry points, a significant skew towards anterior placement was observed (70.6% of the impossible entry points), with a smaller fraction being overly lateral (27.5%) or medial (13.7%). On a patient level, the impossibility rate varied widely from 0 to 35% among the different femora examined, with a significantly higher rate seen in younger patients (mean age 55.02 versus 60.32; t-test for independent samples, p = 0.04). CONCLUSIONS: Significant variations exist in surgeons' selection of entry points for proximal femoral nailing, underscoring the task's complexity. Experience does not prevent the choice of unfeasible entry points, emphasizing the inadequacy of a universal approach and pointing towards the necessity for a patient-specific strategy for improved outcomes. TRIAL REGISTRATION NUMBER: DRKS00032465.


Subject(s)
Bone Nails , Femoral Fractures , Fracture Fixation, Intramedullary , Female , Humans , Male , Clinical Competence , Femoral Fractures/surgery , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Observer Variation , Prospective Studies
13.
Arch Orthop Trauma Surg ; 144(5): 2157-2163, 2024 May.
Article in English | MEDLINE | ID: mdl-38613611

ABSTRACT

INTRODUCTION: The standard surgical procedure for unstable ankle fractures is fixation of the lateral malleolus with a plate and screws. This method has a high risk of complications, especially among patients with fragile skin conditions. The aim of this study was to estimate the re-operation rates and identify complications in patients with an unstable ankle fracture, surgically treated with an intramedullary screw or rush pin. MATERIALS AND METHODS: We identified all patients who were surgically treated with either a 3.5-mm screw or rush pin at Aarhus University Hospital, Denmark, from 2012 to 2018. Major complications were re-operations within three months. We included 80 patients, of which 55 (69%) were treated with a 3.5-mm intramedullary screw and 25 (31%) with a rush pin. The majority of the study population was female (59) and the mean age was 75 (range 24 to 100) years. Of the 80 patients included, 41 patients had more than 2 comorbidities. RESULTS: Three patients underwent re-operation within three months due to either fracture displacement or hardware cutout. Radiographs obtained after six weeks showed that nine patients had loss of reduction. Additionally, four patients had superficial wound infections and six patients had delayed wound healing. CONCLUSIONS: Intramedullary fixation of distal fibula fractures with either a screw or rush pin has low re-operation rates. However, the high proportion of patients with radiological loss of reduction is concerning.


Subject(s)
Ankle Fractures , Bone Nails , Bone Screws , Fracture Fixation, Intramedullary , Reoperation , Humans , Female , Ankle Fractures/surgery , Male , Retrospective Studies , Middle Aged , Adult , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Aged , Aged, 80 and over , Reoperation/statistics & numerical data , Young Adult , Postoperative Complications/epidemiology
14.
Comput Biol Med ; 174: 108419, 2024 May.
Article in English | MEDLINE | ID: mdl-38583229

ABSTRACT

INTRODUCTION: In literature, there have been many studies conducted to research the alternatives of standard interlocking intramedullary nailing. The expandable wedge locked nail fixation, which is thought as a new alternative to the standard interlocking nailing, has been presented in previous numerical studies. The antegrade usage of the wedge locked nail fixation has provided promising results. From this point, the aim of the study is to evaluate mechanical behavior of its retrograde usage on femur models. Additionally, another aim of the study is to investigate the effect of fracture level on mechanical properties of the fixation. MATERIALS AND METHODS: The mechanical behaviors of the wedge locked nail and standard interlocking nail fixations were compared by finite element methods. Sawbones femurs having osteotomies at five different levels to simulate different fractures were fixed with wedge locked nail or interlocking nail by using retrograde approach. With respect to the fracture level, two different nail lengths were used. Axial compression load was applied to fixations. The mechanical behaviors of the fixations were evaluated with respect to stiffness of the fixations and stresses occurred on both implants and bones. RESULTS: Any of the wedge locked nail fixation did not slip at canal. The stress and stiffness results were mostly close with each other for both nail types. The maximum stresses at locking elements or bones contacting these elements increased with decreased distance between the fracture and relevant locking elements. DISCUSSION: The wedge locked nail fixation showed comparable results to the standard interlocking nail fixation with respect to the stiffness and stress. Under axial loading, wedge locked nail provided a secured fixation without any slippage and preserved its position inside the medullary canal. It may be thought as a safe alternative to the standard interlocking nail fixation for retrograde usage. Additionally, according to stress results, it is advised to the surgeons to avoid a close locking to the fracture line.


Subject(s)
Bone Nails , Finite Element Analysis , Fracture Fixation, Intramedullary , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Femoral Fractures/surgery , Femoral Fractures/physiopathology , Biomechanical Phenomena , Femur/surgery , Models, Biological
15.
Injury ; 55(6): 111516, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38604112

ABSTRACT

OBJECTIVES: The aim of this study was to compare the radiological and clinical results of femoral diaphyseal fractures operated in the lateral decubitus position with those operated in the supine position on a traction table and to detail the perioperative surgical technique. PATIENTS AND METHODS: Between October 2018 and January 2022, in this prospective, randomized, and single-blind comparative study, 75 patients diagnosed with adult femoral diaphyseal fractures to whom intramedullary nails were applied were operated in the lateral decubitus position without a traction table (Group 1, 37 patients) and in the supine position with a traction table (Group 2, 38 patients). Preoperative age, gender, fracture mechanism, fracture type, and surgical waiting times were determined. Perioperative anesthesia type, surgery preparation time, surgical time, number of fluoroscopy doses, amount of bleeding, and type of reduction were evaluated, and detailed observational descriptions of the surgical techniques were made. In the postoperative period, radiological evaluations were made with x-ray radiography and orthoroentgenogram, while in the clinical evaluation, hip-knee joint range of motion and rotational evaluation were made with the Craigs test. Follow-up periods were determined and complications noted. RESULTS: The average age was 32 in Group 1 and 28 in Group 2, the female/male ratio was 1:36 in Group 1 and 5:33 in Group 2, and the follow-up period was 18.2 months Group 1 and 21.7 months in Group 2. No significant difference was detected between the groups in terms of age, gender, fracture mechanism, fracture type, anesthesia type, surgical waiting time, and follow-up period (p > 0.05). Compared to Group 2, the shorter preparation time, surgical time, and number of fluoroscopy doses in Group 1 were found to be statistically significant (p < 0.05). The differences in the amount of bleeding and need for open reduction were not statistically significant between the groups (p > 0.05), and no statistical difference was found in joint range of motion and rotational evaluation in clinical evaluation in both groups (p > 0.05). There was no significant difference in terms of complications between groups. CONCLUSIONS: We found the lateral decubitus method without a traction table to be a safe and effective alternative to the supine method with a traction table in terms of the radiological and clinical results and that it also has the advantages of shortening the surgical time, reducing radiation exposure. LEVEL OF EVIDENCE: Level 1 prospective, randomized, single-blind controlled study.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Patient Positioning , Traction , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Female , Male , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Adult , Prospective Studies , Traction/methods , Patient Positioning/methods , Treatment Outcome , Single-Blind Method , Range of Motion, Articular , Middle Aged , Diaphyses/surgery , Diaphyses/injuries , Supine Position , Bone Nails , Operative Time , Young Adult , Radiography , Fracture Healing/physiology
16.
Injury ; 55(6): 111540, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38622039

ABSTRACT

OBJECTIVES: In far-distal extra-articular tibia fracture "extreme" nailing, debate surrounds the relative biomechanical performance of plating the fibula compared with extra distal interlocks. This study aimed to evaluate several constructs for extreme nailing including one interlock (one medial-lateral interlock), one interlock + plate (one medial-lateral interlock with lateral fibula compression plating), and two interlocks (one medial-lateral interlock and one anterior-posterior interlock). METHODS: Fifteen pairs of fresh cadaver legs were instrumented with a tibial nail to the physeal scar. A 1 cm segment of bone was resected from the distal tibia 3.5 cm from the joint and an oblique osteotomy was made in the distal fibula. We loaded specimens with three different distal fixation constructs (one interlock, one interlock + plate, and two interlocks) through 10,000 cycles form 100N-700 N of axial loading. Load to failure (Newtons), angulation and displacement were also measured. RESULTS: Mean load to failure was 2092 N (one interlock), 1917 N (one interlock + plate), and 2545 N (two interlocks). Linear mixed effects modeling demonstrated that two interlocks had a load to failure 578 N higher than one interlock alone (95 % CI, 74N-1082 N; P = 0.02), but demonstrated no significant difference between one interlock and one interlock + plate. No statistically significant difference in rates or timing of displacement >2 mm or angulation >10° were demonstrated. CONCLUSIONS: When nailing far-distal extra-articular tibia and fibula fractures, adding a second interlock provides more stability than adding a fibular plate. Distal fibula plating may have minimal biomechanical effect in extreme nailing.


Subject(s)
Bone Nails , Bone Plates , Cadaver , Fibula , Fracture Fixation, Intramedullary , Tibial Fractures , Humans , Tibial Fractures/surgery , Tibial Fractures/physiopathology , Biomechanical Phenomena , Fibula/surgery , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Male , Female , Weight-Bearing/physiology , Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Aged, 80 and over
17.
Injury ; 55(6): 111533, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38631082

ABSTRACT

Diaphyseal fractures of the tibia is a common injury with an incidence of 16.9/100,000 population. Surgical treatment with intramedullary interlocking nail is the treatment of choice in closed diaphyseal tibial injuries. Removal of the nail is required in non-union, infected implant, implant failure or during exchange nailing procedure. Implant removal surgery presents some unique challenges to the Orthopaedic surgeons like broken nails, broken screws and failure of the extraction devices to engage with the threads of the nail due to stripping of the threads in the proximal part of the nail. Various techniques have been described by different authors to extract a broken distal piece of the nail. There are only a few articles described for the removal of an intramedullary nail when there is failure of the proximal extraction device. The failure of the proximal extraction device occurs due to the use of ill-fitting extraction bolts, cross threading and the presence of a very tight nail leading to stripping of the proximal threads. We describe a simple and novel technique with the use of the Stainless-Steel wire along with the extraction bolt when there is a failure of proximal extraction device for the extraction of cannulated or solid intramedullary nails.


Subject(s)
Bone Nails , Device Removal , Fracture Fixation, Intramedullary , Tibial Fractures , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Device Removal/methods , Tibial Fractures/surgery , Male , Treatment Outcome , Adult , Female , Equipment Failure , Middle Aged
18.
Injury ; 55(6): 111530, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38637188

ABSTRACT

Newer intramedullary (IM) nails have become another option in the fixation of proximal tibia fractures. There is limited data on the successful use of these implants in intra-articular and extra-articular fractures of the proximal tibia, and no studies assessing the ability of these implants to maintain alignment with early weight bearing. Our objective was to determine whether immediate weight bearing after IM fixation, with or without supplemental plate or screw fixation, of proximal third tibial fractures (OTA/AO 41A-C) results in a change in alignment prior to union. 35 patients with 39 proximal tibia fractures from 2015 to 2020, all treated with IM nailing with or without supplemental plate or screw fixation, all made weight-bearing as tolerated following surgery, were included. The main outcomes were change in medial proximal tibial angle (MPTA) and posterior proximal tibial angle (PPTA) from initial post-operative films to final follow up. 12 fractures were OTA/AO 41 type A, 14 were type B, and 13 were type C. Mean initial MPTA was 87.0 +/-2.53 degrees, while mean initial PPTA was 79.6 +/- 3.50 degrees. The mean change in MPTA was 0.048 +/- 2.8 degrees (P=0.92), and mean change in PPTA was 0.264 +/- 3.67 degrees. 92.3% of fractures had normal final coronal plane alignment, with MPTA between 85.0 and 90.0 degrees. 89.7% of fractures had normal final sagittal plane alignment, with PPTA between 77.0 and 84.0 degrees. No patients required reoperation for malalignment. In OTA/AO type 41 fractures, immediate weight bearing after IM nail fixation, with or without supplemental plate or screw fixation when indicated, leads to minimal change in final coronal or sagittal alignment, and was well tolerated in most patients. [authors blinded for review].


Subject(s)
Bone Nails , Bone Plates , Fracture Fixation, Intramedullary , Tibial Fractures , Weight-Bearing , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Weight-Bearing/physiology , Tibial Fractures/surgery , Tibial Fractures/physiopathology , Male , Female , Adult , Middle Aged , Treatment Outcome , Fracture Healing/physiology , Retrospective Studies , Bone Screws , Aged , Young Adult , Radiography
19.
Medicine (Baltimore) ; 103(14): e37647, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579094

ABSTRACT

BACKGROUND: Blocking screw technique has been widely applied in the treatment of long shaft fractures. However, the evidence with regard to whether intramedullary nail combined with blocking screw technique has better clinical efficacy over other is not clear. The aim of the study was to explore the clinical efficacy and complications of intramedullary nail combined with blocking screw technique in the treatment of femoral or tibial shaft fractures. METHODS: The PuMed, Embase, OVID, Cochrane library, Web of Science, Wanfang, CNKI and Weipu data were searched for studies of intramedullary nail combined with blocking screw in treatment of femoral or tibial shaft fracture published up to Aug 31 2023. Methodological quality of the trials was assessed, relevant data were extracted, and RevMan 5.3 and Stata 15.0 software were used to perform the meta-analysis of parameters related to the consequences. RESULT: Twenty articles were included, including 1267 patients. Meta-analysis results showed that compared with the non-blocking screw group, the blocking screw group had longer operation time (WMD = 13.24; 95% CI = 5.68-20.79, P = .0006) and more intraoperative fluoroscopy times (WMD = 57.62; 95% CI = 25.82-89.42, P = .0002). However, the postoperative therapeutic response rate was higher (OR = 5.60; 95% CI = 2.10-14.93, P = .0006), postoperative ankle joint function was better (OR = 3.48; 95% CI = 1.20-10.13, P = .02), and fracture healing rate was higher (OR = 3.56; 95% CI = 1.43-8.89, P = .006), fracture healing time was shorter (WMD = -3.59; 95% CI = -4.96 to -2.22, P < .00001), intraoperative blood loss was less (WMD = -54.80; 95% CI = -88.77 to -20.83, P = .002), hospitalization time was shorter (WMD = -1.66; 95% CI = -2.08 to -1.24, P < .00001), and complications were less (OR = 0.38; 95% CI = 0.16-0.89, P = .01). There was no statistical significance in the range of motion of knee joint between the 2 groups (WMD = 10.04; 95% CI = -1.51 to 21.59, P = .09). CONCLUSIONS: Current evidence shows that intramedullary nail combined with blocking screw technique in the treatment of lower limb long bone fracture has the advantages of good clinical efficacy, high fracture healing rate, short fracture healing time, good joint function, less complications and so on, which is worthy of clinical recommendation.


Subject(s)
Fracture Fixation, Intramedullary , Tibial Fractures , Humans , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/methods , Bone Screws , Treatment Outcome , Tibial Fractures/surgery , Lower Extremity , Bone Nails
20.
J Am Acad Orthop Surg ; 32(11): e514-e522, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38626351

ABSTRACT

Subtrochanteric femur fractures have a reputation as difficult orthopaedic injuries to treat. Strong deforming forces, including the hip musculature and high physiologic forces, must be counteracted to obtain and maintain reduction. Adding to the complexity is a wide variety of fracture morphologies that must be recognized to execute an appropriate surgical plan. The challenging nature of this injury is demonstrated by nonunion rates of 4% to 5%, but some series have reports of up to 15% and malunion rates of 10% to 15%. Improved outcomes have been shown to be dependent on appropriate reduction and stable fixation, which can be achieved with less surgical insult. The treating surgeon must have a thorough understanding of the injury characteristics and reduction techniques to appropriately execute minimally invasive techniques for these difficult fractures.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary , Hip Fractures , Minimally Invasive Surgical Procedures , Humans , Minimally Invasive Surgical Procedures/methods , Hip Fractures/surgery , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Internal/methods , Femoral Fractures/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...