Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 151
Filter
2.
Jt Dis Relat Surg ; 32(2): 454-460, 2021.
Article in English | MEDLINE | ID: mdl-34145824

ABSTRACT

OBJECTIVES: The aim of this study is to investigate whether rigid fixation after triple pelvic osteotomy (TPO) utilizing a 3.5-mm locking plate and screws without hip spica cast can provide enough stability and prevent correction loss in pediatric patients with developmental dysplasia of the hip (DDH) and Legg-Calvé-Perthes disease (LCPD). PATIENTS AND METHODS: A total of 21 hips of 21 pediatric patients (9 males, 12 females; mean age: 9.3±2.0 years; range, 6 to 14 years) who underwent rigid fixation with locking plate/screws after TPO for DDH and LCPD between June 2015 and October 2018 were retrospectively analyzed. Preoperative, immediate postoperative, and six-month follow-up anteroposterior radiographs were compared for the Wiberg's center-edge angle (CE), Sharp angle, acetabular coverage of the femoral head (ACFH), and center-head distance discrepancy (CHDD). The patient demographics, surgery time, perioperative complications were evaluated. RESULTS: Underlying diagnosis were DDH in 14 patients and LCPD in seven patients. In patients with DDH, postoperative evaluation showed significant increase in the mean CE angle (5.6±16.1° vs. 30.5±9.3°, respectively) and ACFH (46.4±16.8% vs. 84.5±12.1%, respectively), and a significant decrease in the mean Sharp angle (55.3±6.2° vs. 35.6±7.8°, respectively) and CHDD (14.6±10.7% vs. 6.2±5.6%, respectively). The final follow-up revealed that there was no correction loss in these parameters. In the patients with LCPD, postoperative evaluation showed a significant increase in the mean CE (20.1±11.1° vs. 38.3±9.6°, respectively) and ACFH (62.9±18% vs. 91.4±10.1%, respectively), and a significant decrease in the mean Sharp angle (46±3.6° vs. 25.2±5.5°, respectively). The final follow-up revealed that there was no correction loss in radiological parameters. No perioperative complications were noted. CONCLUSION: Our study results suggest that rigid fixation construct with a 3.5-mm locking plate and screws without hip spica cast can provide adequate stability to allow early mobilization following TPO in children without any loss of correction, until bony healing at the osteotomy sites.


Subject(s)
Bone Plates/statistics & numerical data , Bone Screws/statistics & numerical data , Casts, Surgical/statistics & numerical data , Hip Dislocation/surgery , Legg-Calve-Perthes Disease/surgery , Osteotomy/statistics & numerical data , Pelvic Bones/surgery , Adolescent , Child , Female , Humans , Male , Retrospective Studies , Treatment Outcome , Turkey
3.
Jt Dis Relat Surg ; 32(2): 468-477, 2021.
Article in English | MEDLINE | ID: mdl-34145826

ABSTRACT

OBJECTIVES: In this study, we describe a novel hemiepiphysiodesis technique to prevent implant-related perichondrial ring injury in a rabbit model. MATERIALS AND METHODS: Proximal tibial epiphyseal plates of a total of 16 white New Zealand rabbits were used for this animal model. The subjects were divided into three equal groups as follows: Group 1 (Kirschner wire [K-wire]/cerclage), Group 2 (8-plate) right-hind legs, Group 3 (Control) left hind legs. Using anteroposterior radiography, the medial slope angle (MSA), articular line-diaphyseal angle (ALDA), and the angle between screws of 8-plate in lateral X-ray tibial slope angle (TSA) were measured. The radiographs were taken early postoperative (Day 1) and on sacrification day (Week 8). The histological evaluation of the perichondrial ring was made on a 7-mm axial section that stained with Safranin O/fast green at X10 magnification. RESULTS: In both K-wire and 8-plate groups, the early postoperative ALDA and TSA were greater than the sacrification ALDA and TSA (p=0.028 and p<0.001, respectively). The early postoperative MSA was lower than the sacrification MSA in groups, (p<0.001). The MSA in the control group was lower than the K-wire and 8-plate groups (p<0.001 and p=0.009; respectively). The perichondrial ring thickness of the K-wire group was greater than the 8-plate group in histological evaluation (p<0.001). CONCLUSION: Both of the K-wire and 8-plate groups showed similar angulation effects in the proximal tibia, although histologically less damage to the perichondrial ring was observed in the K-wire group, compared to the 8-plate group.


Subject(s)
Bone Plates/statistics & numerical data , Bone Wires/statistics & numerical data , Growth Plate/surgery , Tibia/surgery , Animals , Cartilage/diagnostic imaging , Epiphyses , Rabbits , Radiography , Salter-Harris Fractures/surgery
4.
J Bone Joint Surg Am ; 103(21): 2006-2013, 2021 11 03.
Article in English | MEDLINE | ID: mdl-34138780

ABSTRACT

BACKGROUND: A subgroup of pertrochanteric fractures-namely, the AO/OTA 31A3 fracture-continues to be a difficult problem to treat, even with cephalomedullary nails. We present the results for 26 patients with a 31A3 fracture treated with the angled blade plate. METHODS: The records of 26 consecutive patients with a 31A3 fracture that was treated operatively with the angled blade plate device between 2007 and 2012 at our center were reviewed, and the patients were contacted for follow-up. The functional outcome (traumatic hip rating score) and radiographic outcome (the neck-shaft angle at the time of fixation and final follow-up) were obtained for 20 of the 26 patients at a minimum follow-up of 1 year. RESULTS: All 26 patients had primary surgery. At final review, 2 patients had died and 4 had been lost to follow-up. Of the 4 patients lost to follow-up, 2 had revision of the fixation with the angled blade plate. Of the 20 patients with follow-up, 1 had malreduction and implant failure but eventually had healing after revision of the fixation with the angled blade plate. The mean traumatic hip rating score at the time of follow-up was 50.0 with 4, 14, and 2 patients having excellent, good, and failed outcomes, respectively. The mean neck-shaft angle at the time of final union was 126.16°, which was an average of 4° less than that on the unaffected side. However, this did not correlate with functional outcome. There was no significant difference between the immediate postoperative and final neck-shaft angles. CONCLUSIONS: This study demonstrated that blade plate fixation for 31A3 fractures is associated with low rates of failure (15%), revision surgery (15%), and infection (15%), which are comparable with the results of nail fixation (range, 5% to 12%) and superior to those of sliding hip screw fixation. This large series demonstrates that the angled blade plate can be utilized for these complex fractures and should be part of the armamentarium for these injuries. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Bone Plates/adverse effects , Fracture Fixation, Internal/adverse effects , Hip Fractures/surgery , Surgical Wound Infection/epidemiology , Adult , Aged , Aged, 80 and over , Bone Nails/adverse effects , Bone Nails/statistics & numerical data , Bone Plates/statistics & numerical data , Bone Screws/adverse effects , Bone Screws/statistics & numerical data , Feasibility Studies , Female , Follow-Up Studies , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Healing , Humans , Male , Middle Aged , Reoperation/statistics & numerical data , Retrospective Studies , Surgical Wound Infection/etiology , Treatment Outcome , Young Adult
5.
Laryngoscope ; 131(9): 1997-2005, 2021 09.
Article in English | MEDLINE | ID: mdl-33571385

ABSTRACT

OBJECTIVES/HYPOTHESIS: To determine the frequency and management of short- and long-term complications related to oromandibular free flap reconstruction and identify potentially predictive factors of hardware complications. STUDY DESIGN: Retrospective chart review. METHODS: A retrospective database from chart review was formed consisting of 266 oromandibular free flap reconstructions performed at a single institution over a 15-year period. Data were collected on demographics, surgical treatment, complications, and management of complications. Subgroup univariate and multivariate analyses were performed to compare patients with hardware complications and those without. RESULTS: Eighty-one of 266 patients (30.5%) that underwent oromandibular reconstruction had an early complication (<4 weeks after surgery), and the most common complications were cervical wound dehiscence (11.3%) and fistulas (9.40%). Eighty of 266 patients (30.1%) had a long-term complication (>4 weeks after surgery) and the most common complication was plate exposure (26.7%). Univariate and multivariate analyses showed no association between whether there was hardware extrusion and fibula versus scapula, smoking history, virtual surgical planning (VSP), and dental implantation (P > .05). Only early complications (OR, 3.59, 95% CI, 1.83-7.05, P < .01) and patients undergoing oromandibular reconstruction for osteoradionecrosis (OR, 2.26, 95% CI, 1.10-4.64, P = .03) were strongly and independently associated with subsequent hardware extrusion on univariate analysis. CONCLUSIONS: Both short- and long-term complications are common after oromandibular reconstruction. The most important predictive factor for a late complication is an early complication and prior radiation. There was no difference of plate complications among the various free flap types. Dental implantation and use of VSP were not associated with hardware complications. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:1997-2005, 2021.


Subject(s)
Bone Plates/statistics & numerical data , Free Tissue Flaps/adverse effects , Mandibular Reconstruction/methods , Plastic Surgery Procedures/adverse effects , Postoperative Complications/pathology , Adult , Aged , Bone Plates/adverse effects , Case-Control Studies , Comorbidity , Female , Fibula/transplantation , Fistula/epidemiology , Free Tissue Flaps/transplantation , Humans , Male , Mandibular Reconstruction/statistics & numerical data , Middle Aged , Multivariate Analysis , Osteoradionecrosis/epidemiology , Postoperative Complications/epidemiology , Predictive Value of Tests , Retrospective Studies , Scapula/transplantation , Surgical Wound Dehiscence/epidemiology
6.
Plast Reconstr Surg ; 147(2): 240e-252e, 2021 02 01.
Article in English | MEDLINE | ID: mdl-33235040

ABSTRACT

BACKGROUND: This study performs an economic analysis of volar locking plate, external fixation, percutaneous pinning, or casting in elderly patients with closed distal radius fractures. METHODS: This is a secondary analysis of the Wrist and Radius Injury Surgical Trial, a randomized, multicenter, international clinical trial with a parallel nonoperative casted group of patients older than 60 years with surgically indicated, extraarticular closed distal radius fractures. Thirty-Six-Item Short-Form Health Survey-converted utilities and total costs from Medicare were used to calculate quality-adjusted life-years and incremental cost-effectiveness ratio. RESULTS: Casted patients were self-selected and older (p < 0.001) than the randomized surgical cohorts, but otherwise similar in sociodemographic characteristics. Quality-adjusted life-years for percutaneous pinning were highest at 9.17 and external fixation lowest at 8.81. Total costs expended were $16,354 for volar locking plates, $16,012 for external fixation, $11,329 for percutaneous pinning, and $6837 for casting. The incremental cost-effectiveness ratios for volar locking plates and external fixation were dominated by percutaneous pinning and casting. The ratio for percutaneous pinning compared to casting was $28,717. Probabilistic sensitivity analysis revealed a 10, 5, 53, and 32 percent chance of volar locking plate, external fixation, percutaneous pinning, and casting, respectively, being cost-effective at the willingness-to-pay threshold of $100,000 per quality-adjusted life-year. CONCLUSIONS: Casting is the most cost-effective treatment modality in the elderly with closed extraarticular distal radius fractures and should be considered before surgery. In unstable closed fractures, percutaneous pinning, which is the most cost-effective surgical intervention, may be considered before volar locking plates or external fixation.


Subject(s)
Fracture Fixation, Internal/economics , Health Care Costs/statistics & numerical data , Postoperative Complications/epidemiology , Radius Fractures/surgery , Wrist Injuries/surgery , Age Factors , Aged , Aged, 80 and over , Bone Plates/economics , Bone Plates/statistics & numerical data , Casts, Surgical/economics , Casts, Surgical/statistics & numerical data , Cost-Benefit Analysis , Female , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Humans , Male , Middle Aged , Models, Economic , Postoperative Complications/economics , Postoperative Complications/etiology , Quality-Adjusted Life Years , Radius Fractures/complications , Radius Fractures/economics , Treatment Outcome , United States , Wrist Injuries/complications , Wrist Injuries/economics
7.
Acta Orthop Traumatol Turc ; 54(5): 483-487, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33155556

ABSTRACT

OBJECTIVE: The aim of this study was to compare the clinical outcomes and operative cost of a locked compression plate (LCP) and a nonlocked reconstruction plate in the treatment of displaced midshaft clavicle fracture. METHODS: From January 2013 till March 2018, a total of 55 patients with acute unilateral closed midshaft clavicle fracture were treated with either a 3.5-mm pre-contoured LCP [32 patients; 25 men and 7 women; mean age: 35 years (range: 19-63 years)] or a 3.5-mm nonlocked reconstruction plate [23 patients; 20 men and 3 women; mean age: 31.4 years (range: 17-61 years)]. The clinical outcomes in terms of fracture union, Quick Disability of Arm, Shoulder and Hand (DASH) score, implant irritation, failure rate, and reoperation rate were evaluated retrospectively. The patient billing records were reviewed to obtain primary operation, reoperation, and total operative cost for midshaft clavicle fracture. These values were analyzed and converted from Malaysia Ringgit (RM) to United States Dollar (USD) at the exchange rate of RM 1 to USD 0.24. All patients were followed up for at least one-year duration. RESULTS: The mean time to fracture union, implant irritation, implant failure, and reoperation rate showed no significant difference between the two groups of patients. The mean Quick DASH score was significantly better in the reconstruction plate group with 13 points compared with 28 points in the LCP group (p=0.003). In terms of total operative cost, the LCP group recorded a cost of USD 391 higher than the reconstruction plate group (p<0.001). CONCLUSION: The 3.5-mm reconstruction plate achieved not only satisfactory clinical outcomes but was also more cost-effective than the LCP in the treatment of displaced midshaft clavicle fractures. LEVEL OF EVIDENCE: Level III, Therapeutic study.


Subject(s)
Bone Plates , Clavicle , Costs and Cost Analysis , Fractures, Bone , Adult , Bone Plates/economics , Bone Plates/statistics & numerical data , Clavicle/injuries , Clavicle/surgery , Costs and Cost Analysis/methods , Costs and Cost Analysis/statistics & numerical data , Female , Fracture Fixation, Internal/economics , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Healing , Fractures, Bone/economics , Fractures, Bone/surgery , Fractures, Malunited/economics , Fractures, Malunited/surgery , Humans , Male , Reoperation/economics , Reoperation/methods , Retrospective Studies , Treatment Outcome
8.
J Med Primatol ; 49(6): 352-355, 2020 12.
Article in English | MEDLINE | ID: mdl-32779224

ABSTRACT

This case reports the successful management of a traumatic diaphyseal femoral fracture in an infant Western chimpanzee (Pan troglodytes verus) from a rescue centre in Sierra Leone using a 2.4-mm intramedullary pin and two 2.7-mm String of Pearls™ locking plates. Locking plate use has not been previously described in chimpanzees.


Subject(s)
Bone Nails/veterinary , Bone Plates/veterinary , Femoral Fractures/veterinary , Pan troglodytes/injuries , Animals , Animals, Zoo/injuries , Animals, Zoo/surgery , Bone Nails/statistics & numerical data , Bone Plates/statistics & numerical data , Diaphyses/pathology , Female , Femoral Fractures/surgery , Pan troglodytes/surgery , Sierra Leone
9.
J Orthop Res ; 38(12): 2573-2579, 2020 12.
Article in English | MEDLINE | ID: mdl-32470168

ABSTRACT

To assess whether far-cortical locking (FCL) screws alter the fracture site strain environment and allow shorter bridge plate constructs for supracondylar femoral fractures, we tested the fracture site displacement under force of synthetic left femora with a 5-cm metaphyseal fracture gap, modeling comminution. Five models of nine constructs were tested (three types of diaphyseal screws [nonlocking, locking, and FCL] and two plate lengths [13 holes and 5 holes]). Long plate models using three or four diaphyseal screws (working length 13.5 or 7.5 cm, respectively) were compared with short plates with three diaphyseal screws (working length 7.5 cm). Models were loaded axially and torsionally; 100 cycles in random order. Primary outcome measures were axial and torsional fracture site stiffness. FCL screws decreased rotational stiffness 19% (P < .01) compared with baseline nonlocking screws in the same plate and working length construct, mirroring the effect (20% decrease in stiffness, P < .01) of nearly doubling the nonlocking construct working length (7.5-13.5 cm). Similarly, FCL screws decreased axial stiffness 23% (P < .01) in the same baseline comparison. Fracture site displacement under loading comparable to a long working length nonlocked plate construct was achieved using a shorter FCL plate construct. By closely replicating the biomechanical properties of a long plate construct, a fracture site strain environment considered favorable in promoting fracture healing might still be achievable using a shorter plate length. Clinical Significance: It might be possible to optimize fracture site strain environment and displacement under loading using shorter FCL plate constructs. Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 00:00-00, 2020.


Subject(s)
Bone Plates/statistics & numerical data , Bone Screws/statistics & numerical data , Femoral Fractures/surgery , Fracture Fixation, Internal/instrumentation , Humans
10.
BMC Musculoskelet Disord ; 21(1): 91, 2020 Feb 10.
Article in English | MEDLINE | ID: mdl-32041567

ABSTRACT

BACKGROUND: To compare the outcomes after surgical intervention, including external fixation (EF) with the optional addition of K-pins or open reduction and internal fixation (ORIF) with a volar locking plate (VLP), in patients with distal radius fracture aged > 80 years. METHODS: We reviewed 69 patients with a distal radius fracture aged > 80 years who treated under surgical intervention from 2011 to 2017 retrospectively. Their demographic data and complications were recorded. Preoperative, postoperative, and last follow-up plain films were analyzed. The functional outcomes of wrist range of motion were also evaluated. RESULTS: 41 patients were treated with EF with the optional addition of K-pins, while 28 patients were treated with ORIF with a VLP. The radiological parameters, including ulnar variance and radial inclination, at the last follow-up were significantly more acceptable in the VLP group (p = 0.01, p = 0.03, respectively). The forearm supination was significantly better in patients treated with VLP (p = 0.002). The overall incidence of complications was lower in the VLP group (p = 0.003). CONCLUSION: VLP provides better radiological outcomes, wrist supination and lower complication rates than EF. Therefore, although EF is still widely used because of its acceptable results and easy application, we recommend VLP as a suitable treatment option for distal radius fracture in the geriatric population aged > 80 years.


Subject(s)
Bone Plates/statistics & numerical data , External Fixators/statistics & numerical data , Fracture Fixation, Internal/instrumentation , Radius Fractures/surgery , Wrist Injuries/surgery , Aged, 80 and over , Female , Humans , Male , Postoperative Complications/epidemiology , Radiography , Radius Fractures/diagnostic imaging , Range of Motion, Articular , Retrospective Studies , Taiwan/epidemiology , Treatment Outcome , Wrist Injuries/diagnostic imaging
11.
Acta Orthop Belg ; 86(2): 220-226, 2020 Jun.
Article in English | MEDLINE | ID: mdl-33418610

ABSTRACT

Various plating systems are available to fix distal radius fractures, each with a specific design. The purpose of this study was to compare radiological outcome and complications of the Variable Angle LCP Plate 2.4-mm (DePuy Synthes) with the VariAx volar locking plate (Stryker). One hundred patients (103 wrists) operated on for a distal radius fracture were retrospectively reviewed with a mean follow-up of 3.5 years. Seventy-three wrists were treated with a DePuy Synthes plate and 30 with a VariAx plate. The overall complication rate was 32%. Nineteen cases underwent revision surgery, 18 had malunion and 3 complex regional pain syndrome. Complicaton rate was 43% with DePuy Synthes plates and 27% with Variax plates, but the difference was not significant.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Fractures, Malunited , Pain, Postoperative , Postoperative Complications , Radius Fractures/surgery , Wrist Injuries , Bone Plates/adverse effects , Bone Plates/classification , Bone Plates/statistics & numerical data , Bone Screws , Comparative Effectiveness Research , Female , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Malunited/diagnostic imaging , Fractures, Malunited/etiology , Humans , Male , Middle Aged , Outcome and Process Assessment, Health Care , Pain, Postoperative/diagnosis , Pain, Postoperative/etiology , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Postoperative Complications/physiopathology , Postoperative Complications/surgery , Radiography/methods , Radius Fractures/diagnosis , Radius Fractures/etiology , Reoperation/methods , Wrist Injuries/diagnosis , Wrist Injuries/surgery
12.
Injury ; 51(2): 389-394, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31668577

ABSTRACT

INTRODUCTION: Nonunions of trochanteric femoral fractures are uncommon due to a good blood supply of the cancellous bone of the trochanteric region. Nevertheless, if a nonunion occurs, complex revision procedures usually become necessary. The purpose of this study was to evaluate a series of aseptic trochanteric nonunions in patients aged 60 years or older, looking at outcomes regarding healing rate, implant-related complications and secondary surgeries. MATERIAL AND METHODS: We conducted a retrospective chart review of patients with aseptic femoral trochanteric nonunions aged over 60 years. Nonunion treatment consisted of implant removal, debridement of the nonunion, and restoration of the neck shaft angle, followed by DCS plating. An additional 4.5-mm limited contact dynamic compression plate was placed in twelve patients anteriorly. The primary outcome measure was bony healing and time to healing in months. Secondary outcome measures included postoperative complications related to the index procedure, range of motion of the affected hip and postoperative mobility. RESULTS: A total of 21 patients with a mean age of 69.1 years met the inclusion criteria. After a mean follow-up of 21.62 months, 17 of the 21 nonunions healed successfully. The mean healing time was 6.59 months. A total of six of the 21 patients needed secondary revision surgery. At the final follow-up, a full range of motion of the hip was seen in 17 of the 21 hips. CONCLUSIONS: DCS treatment and preservation of the patient's femoral head can be successful for patients aged over 60 years with a well-preserved femoral head and acetabulum. However, preservation of the hip joint and revision plating might be associated with higher revision rates.


Subject(s)
Bone Plates/adverse effects , Bone-Anchored Prosthesis/adverse effects , Fractures, Ununited/etiology , Fractures, Ununited/surgery , Hip Fractures/surgery , Aged , Aged, 80 and over , Bone Plates/statistics & numerical data , Bone Screws , Bone-Anchored Prosthesis/microbiology , Female , Follow-Up Studies , Fracture Healing/physiology , Fractures, Ununited/diagnostic imaging , Fractures, Ununited/microbiology , Hip Fractures/complications , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Range of Motion, Articular/physiology , Reoperation/statistics & numerical data , Retrospective Studies , Treatment Outcome
13.
J Orthop Trauma ; 33 Suppl 8: S33-S37, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31688525

ABSTRACT

Pediatric pelvic fractures are rare and differ from adults in etiology, fracture type, and associated injuries. They are observed in multitrauma patients, with severe associated injuries. Treatment of these children in specialized hospitals is likely to provide the best outcome because of the rarity of these fractures. Only a small percentage of the fractures, particularly the displaced ones, need operative treatment with the aim to restore the anatomy of the pelvic ring. In a significant proportion of the operated patients, morbidity and mortality were not linked to the pelvic fractures but to the other associated injuries. Long-term prognosis depends on restoring pelvic symmetry. Nondisplaced fractures of the acetabulum or fractures with minimal displacement with a relatively low roof-arc angle or crush injuries of the triradiate physis are managed nonoperatively. In young patients where continuation of growth is expected, fixation that does not cross the physis anatomically could be used. In some very young children, plate removal may be indicated to allow for continued growth of the acetabulum. One of the major complications in this patient cohort is acetabular dysplasia.


Subject(s)
Acetabulum/immunology , Fracture Fixation, Internal/methods , Fracture Healing/physiology , Fractures, Bone/surgery , Pelvic Bones/immunology , Acetabulum/surgery , Adolescent , Age Factors , Bone Nails/statistics & numerical data , Bone Plates/statistics & numerical data , Child , Female , Fractures, Bone/diagnostic imaging , Fractures, Bone/epidemiology , Humans , Injury Severity Score , Male , Pediatrics/methods , Pelvic Bones/surgery , Rare Diseases , Risk Assessment , Sex Factors
14.
J Orthop Trauma ; 33(11): e427-e432, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31634288

ABSTRACT

OBJECTIVES: As hospitals seek to control variable expenses, orthopaedic surgeons have come under scrutiny because of relatively high implant costs. We aimed to determine whether feedback to surgeons regarding implant costs results in changes in implant selection. METHODS: This study was undertaken at a statewide trauma referral center and included 6 fellowship-trained orthopaedic trauma surgeons. A previously implemented implant stewardship program at our institution using a "red-yellow-green" (RYG) implant selection tool classifies 7 commonly used trauma implant constructs based on cost and categorizes each implant as red (used for patient-specific requirements, most expensive), yellow (midrange), and green (preferred vendor, least expensive). The constructs included were femoral intramedullary nail, tibial intramedullary nail, long and short cephalomedullary nails, distal femoral plate, proximal tibial plate, and lower-limb external fixator. Baseline implant usage from the previous year was obtained and provided to each surgeon. Each surgeon received a monthly feedback report containing individual implant utilization and overall ranking. RESULTS: The overall RYG score increased from 68.7 to 79.1 of 100 (P < 0.001). Three of the 7 implants (tibial and femoral nails and lower-limb external fixation) had significant increases in their RYG scores; implant selections for the other 4 implants were not significantly altered. A decrease of 1.8% (95% confidence interval, 0.4-3.2, P = 0.01) was noted in overall implant costs over the study period. CONCLUSION: Our intervention resulted in changes in surgeons' implant selections and cost savings. However, surgeons were unwilling to change certain implants despite their being more expensive.


Subject(s)
Bone Nails/statistics & numerical data , Bone Plates/statistics & numerical data , Cost-Benefit Analysis , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Intramedullary/instrumentation , Fractures, Bone/surgery , Bone Nails/economics , Bone Plates/economics , Cost Savings , Female , Fracture Fixation, Internal/methods , Fracture Fixation, Intramedullary/methods , Fractures, Bone/diagnosis , Humans , Male , Middle Aged , Retrospective Studies , Task Performance and Analysis , Trauma Centers , United States
16.
JBJS Rev ; 7(5): e7, 2019 May.
Article in English | MEDLINE | ID: mdl-31145263

ABSTRACT

BACKGROUND: Aseptic glenoid baseplate loosening can lead to the failure of reverse total shoulder arthroplasty (RTSA). Estimates of the prevalence of aseptic glenoid baseplate loosening after RTSA are required to guide clinical decisions, but published results are variable and lack precision. The goal of this meta-analysis was to determine a precise estimate of the prevalence of aseptic glenoid baseplate loosening after RTSA and to explore variation in the prevalence according to different variables, such as the type of procedure (primary or revision), preoperative diagnosis, the center of rotation of the glenoid component (medialized or lateralized), study size, the definition of aseptic glenoid baseplate loosening, and the duration of follow-up. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. We searched the MEDLINE and Embase databases for English-language articles describing the outcomes after RTSA with a minimum 12-month follow-up in which radiographic findings of aseptic glenoid baseplate loosening were reported. Random-effects meta-analysis was performed, and meta-regression was used to explore the influence of variables on heterogeneity. Subgroup analyses and sensitivity analyses were performed. RESULTS: One hundred and three studies (covering 6,583 RTSAs) performed from 1991 to 2015 met our inclusion criteria. The pooled prevalence of radiographic aseptic glenoid baseplate loosening for all RTSAs was 1.16% (95% confidence interval [CI], 0.80% to 1.69%). The prevalence of aseptic glenoid baseplate loosening was lower among primary RTSAs (0.90%; 95% CI, 0.54% to 1.49%) than among revision RTSAs (3.64%; 95% CI, 1.91% to 6.84%). The pooled prevalence of aseptic glenoid baseplate loosening by diagnosis was 2.69% for osteoarthritis with bone loss, 1.71% for cuff tear arthropathy, 1.20% for rheumatoid arthritis, 1.08% for sequelae of fracture, 0.94% for irreparable massive cuff tear, and 0.25% for acute proximal humeral fracture. The prevalence of aseptic glenoid baseplate loosening was not significantly different for prostheses with a medialized center of rotation (1.15%) versus a lateralized center of rotation (1.84%). CONCLUSIONS: To our knowledge, the present study represents the first meta-analysis investigating only aseptic glenoid baseplate loosening after RTSA. Multiple variables were found to be associated with the prevalence of aseptic glenoid baseplate loosening. The rates reported here are lower than those reported previously because of the inclusion of more recent evidence and more studies that evaluated aseptic glenoid baseplate loosening. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Shoulder , Bone Plates , Prosthesis Failure , Shoulder Prosthesis/adverse effects , Arthroplasty, Replacement, Shoulder/adverse effects , Arthroplasty, Replacement, Shoulder/statistics & numerical data , Bone Plates/adverse effects , Bone Plates/statistics & numerical data , Humans , Postoperative Complications , Prevalence , Scapula/surgery
17.
J Shoulder Elbow Surg ; 28(6): e165-e174, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30992248

ABSTRACT

BACKGROUND: The aim of this study was to determine the amount of blood loss and the rate of blood transfusion in patients receiving surgery for proximal humeral fractures depending on the treatment and fracture classification. Moreover, factors associated with blood loss and blood transfusion were analyzed. METHODS: The study included 420 patients who had received surgery for proximal humeral fractures. Data from medical records were collected retrospectively. The calculated blood loss and the transfusion rate were analyzed depending on the type of surgery (plate fixation, arthroplasty, and others) or the fracture classification (2-, 3-, and 4-part fractures). The extent of blood loss and the need for transfusion were correlated with potential risk factors. A score to estimate the probability of blood transfusion was developed. RESULTS: Average blood loss was 284 mL, and the transfusion rate was 14.5% for all proximal humeral fractures. Shoulder arthroplasty was associated with higher blood loss (353 mL, P < .01) and a higher blood transfusion rate (27.3%, P < .01) than plate fixation (263 mL and 10.9%, respectively). The fracture classification had no effect on either factor. Significant risk factors for blood loss were male sex, body mass index, surgery time, time until surgery, and vitamin K antagonists. Age, blood loss, American Society of Anesthesiologists score greater than 2, vitamin K antagonists, coronary artery disease (CAD), peripheral artery disease (PAD), and renal disease were associated with a higher transfusion rate. CONCLUSION: Blood loss could be affected by a shorter surgery time and by choosing an adequate time until surgery. The consideration of risk factors and the use of a transfusion risk score allow more elaborate ordering of cross-matched blood units and can decrease institutional costs.


Subject(s)
Blood Loss, Surgical/statistics & numerical data , Shoulder Fractures/surgery , Aged , Arthroplasty, Replacement, Shoulder/statistics & numerical data , Blood Transfusion/statistics & numerical data , Bone Plates/statistics & numerical data , Cohort Studies , Databases, Factual , Female , Germany/epidemiology , Humans , Injury Severity Score , Male , Middle Aged , Retrospective Studies , Risk Factors , Shoulder Fractures/epidemiology
18.
Hand (N Y) ; 14(4): 554-559, 2019 07.
Article in English | MEDLINE | ID: mdl-29319350

ABSTRACT

Background: Small olecranon fractures present a significant challenge for fixation, which has resulted in development of plates with proximal extension. Olecranon-specific plates with proximal extensions are widely thought to offer superior fixation of small proximal fragments but have distinct disadvantages: larger dissection, increased hardware prominence, and the increased possibility of impingement. Previous biomechanical studies of olecranon fracture fixation have compared methods of fracture fixation, but to date there have been no studies defining olecranon plate fixation strength for standard versus extended olecranon plates. The purpose of this study is to evaluate the biomechanical utility of the extended plate for treatment of olecranon fractures. Methods: Sixteen matched pairs of fresh-frozen human cadaveric elbows were used. Of the 16, 8 matched pairs received a transverse osteotomy including 25% and 8 including 50% of the articular surface on the proximal fragment. One elbow from each pair was randomly assigned to a standard-length plate, and the other elbow in the pair received the extended-length plate, for fixation of the fracture. The ulnae were cyclically loaded and subsequently loaded to failure, with ultimate load, number of cycles, and gap formation recorded. Results: There was no statistically significant difference between the standard and extended fixation plates in simple transverse fractures at either 25% or 50% from the proximal most portion of the articular surface of the olecranon. Conclusion: Standard fixation plates are sufficient for the fixation of small transverse fractures, but caution should be utilized particularly with comminution and nontransverse fracture patterns.


Subject(s)
Biomechanical Phenomena/physiology , Bone Plates/statistics & numerical data , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Bone Plates/adverse effects , Bone Plates/standards , Cadaver , Elbow Joint/surgery , Fracture Fixation, Internal/standards , Fractures, Bone/classification , Fractures, Comminuted/surgery , Humans , Olecranon Process/pathology , Osteotomy/methods , Ulna Fractures/surgery
19.
BMC Musculoskelet Disord ; 19(1): 369, 2018 Oct 12.
Article in English | MEDLINE | ID: mdl-30314495

ABSTRACT

BACKGROUND: Hip fractures are a major worldwide public health problem and includes two main types of fractures: the intracapsular (cervical) and the extracapsular (trochanteric and subtrochanteric) fractures. The aim of this study on patients with trochanteric and subtrochanteric hip fractures was to describe the epidemiology, treatment and outcome in terms of mortality within the context of a large register study. METHODS: A descriptive epidemiological register study including patients registered in the national Swedish Fracture Register from January 2014 to December 2016. Inclusion criteria were all primary surgically treated traumatic non-pathological trochanteric and subtrochanteric femoral fractures in patients aged 18 years and above. Individual patient data (age, gender, injury location, injury cause, fracture type, treatment and timing of surgery) were retrieved from the register database. Mortality data was obtained via linkage to the Swedish Death Register. RESULTS: A total of 10,548 consecutive patients were identified and included in the study. The mean (±SD) age for all patients was 82 ± 11 years and the majority of the patients were females (69%). Most of the fractures were caused by a fall at the same level (83%) at the patients' accommodation (75%). Fractures were classified using the AO/OTA classification as 31-A1 in 29%, as 31-A2 in 49% and as 31-A3 in 22% of the cases. The most commonly used implant was a short antegrade intramedullary nail (42%), followed by a plate with sliding hip screw (37%). With increasing fracture complexity, the proportion of intramedullary nails was increasing, and also the use of long versus short nails. The majority of the patients were operated within 36 h (90%). There was a higher mortality at 30 days and 1 year for males, and for all those who were delayed to surgery > 36 h. CONCLUSION: Safety measures to prevent fall at elderly patient's accommodation might be a way to reduce the number of trochanteric and subtrochanteric hip fractures. Surgery as soon as possible without delay should be considered to reduce the mortality rate. The selection of surgical methods depends on the fracture complexity.


Subject(s)
Accidental Falls , Fracture Fixation, Intramedullary/methods , Hip Fractures/epidemiology , Mortality/trends , Registries/statistics & numerical data , Adult , Aged , Aged, 80 and over , Bone Nails/statistics & numerical data , Bone Plates/statistics & numerical data , Bone Screws/statistics & numerical data , Female , Fracture Fixation, Intramedullary/instrumentation , Hip Fractures/etiology , Hip Fractures/surgery , Humans , Male , Middle Aged , Sex Factors , Sweden/epidemiology , Time-to-Treatment , Young Adult
20.
Bull Tokyo Dent Coll ; 59(2): 67-78, 2018.
Article in English | MEDLINE | ID: mdl-29962423

ABSTRACT

The purpose of this study was to investigate factors involved in stress on locking mini-plate/screws used in orthognathic surgery based on patient-specific 3-dimensional finite element analysis. Data were obtained from 10 patients undergoing mandibular advancement by bilateral sagittal split ramus osteotomy. All underwent osteosynthesis with 2.0-mm titanium locking mini-plate/screws. A 3-dimensional finite element model of the mandible was created for each patient and each model subjected to the same loading conditions, which produced different stress values on locking mini-plate/screws. When the contact area of the proximal and distal bone segments was narrower and bone mineral density (BMD) lower, the von Mises stress values on the plate/screws were higher (contact area, p<0.01; BMD, p<0.05). The present results suggest that bone contact area and BMD should be considered as plate stress factors.


Subject(s)
Finite Element Analysis , Jaw Fixation Techniques/instrumentation , Mandible/surgery , Mandibular Advancement/instrumentation , Osteotomy, Sagittal Split Ramus/instrumentation , Osteotomy, Sagittal Split Ramus/methods , Osteotomy/instrumentation , Osteotomy/methods , Adolescent , Adult , Bone Density , Bone Plates/statistics & numerical data , Bone Screws/statistics & numerical data , Computer Simulation , Equipment Design , Female , Humans , Imaging, Three-Dimensional/methods , Male , Mandibular Advancement/methods , Middle Aged , Models, Anatomic , Orthognathic Surgical Procedures/instrumentation , Orthognathic Surgical Procedures/methods , Stress, Mechanical , Titanium , Young Adult
SELECTION OF CITATIONS