Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 6.833
Filter
1.
BMC Musculoskelet Disord ; 25(1): 449, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38844899

ABSTRACT

BACKGROUND: Patient-specific aiming devices (PSAD) may improve precision and accuracy of glenoid component positioning in total shoulder arthroplasty, especially in degenerative glenoids. The aim of this study was to compare precision and accuracy of guide wire positioning into different glenoid models using a PSAD versus a standard guide. METHODS: Three experienced shoulder surgeons inserted 2.5 mm K-wires into polyurethane cast glenoid models of type Walch A, B and C (in total 180 models). Every surgeon placed guide wires into 10 glenoids of each type with a standard guide by DePuy Synthes in group (I) and with a PSAD in group (II). Deviation from planned version, inclination and entry point was measured, as well as investigation of a possible learning curve. RESULTS: Maximal deviation in version in B- and C-glenoids in (I) was 20.3° versus 4.8° in (II) (p < 0.001) and in inclination was 20.0° in (I) versus 3.7° in (II) (p < 0.001). For B-glenoid, more than 50% of the guide wires in (I) had a version deviation between 11.9° and 20.3° compared to ≤ 2.2° in (II) (p < 0.001). 50% of B- and C-glenoids in (I) showed a median inclination deviation of 4.6° (0.0°-20.0°; p < 0.001) versus 1.8° (0.0°-4.0°; p < 0.001) in (II). Deviation from the entry point was always less than 5.0 mm when using PSAD compared to a maximum of 7.7 mm with the standard guide and was most pronounced in type C (p < 0.001). CONCLUSION: PSAD enhance precision and accuracy of guide wire placement particularly for deformed B and C type glenoids compared to a standard guide in vitro. There was no learning curve for PSAD. However, findings of this study cannot be directly translated to the clinical reality and require further corroboration.


Subject(s)
Arthroplasty, Replacement, Shoulder , Learning Curve , Humans , Arthroplasty, Replacement, Shoulder/methods , Arthroplasty, Replacement, Shoulder/instrumentation , Bone Wires , Glenoid Cavity/surgery , Models, Anatomic , Shoulder Joint/surgery
2.
Clin Orthop Surg ; 16(3): 357-362, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827765

ABSTRACT

Background: Treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments is a challenge. To treat this difficult fracture, we perform articular fragment detachment and separate fixation for coronal split articular and inferior pole fragments. We aimed to evaluate the radiological and clinical outcomes of our technique in comminuted patellar fractures at least 1 year after surgery. Methods: Between January 2019 and June 2022, 15 patients diagnosed with comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments based on preoperative computed tomography underwent surgery using the articular detachment technique. The key point of this technique was anatomical reduction and subchondral fixation of the coronal split articular fragment to the superior main fragment after complete detachment of the coronal split fragment from the inferior pole. The remaining inferior pole was fixed using a separate construct. Postoperative articular gap, articular step-off, and complications, including resorption, reduction loss, and avascular necrosis of fixed articular fragments, were evaluated as radiological outcomes. Range of motion and the Lysholm scores were used to evaluate clinical outcomes. Results: Among the 15 patients, the coronal split articular fragments were fixed using Kirschner wires in 13 patients and headless screws in 2 patients. The inferior poles were fixed using separate vertical wiring in 13 patients and tension-band wiring in 2 patients. A postoperative articular gap was noted in 7 patients, with an average articular gap of 1.0 mm (range, 0.7-1.6 mm). No articular step-off was observed. Bone union and normal range of motion were achieved in all patients. On the 1-year postoperative lateral radiograph, resorption of the articular fracture site was seen in 5 patients. There was no loss of reduction or avascular necrosis of the coronal split articular fragments. The average postoperative Lysholm score at 1 year was 89.3 ± 4.1 (range, 82-95). Conclusions: The technique would be a reliable and safe option for the surgical treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments in terms of anatomical reduction and stable fixation of articular fragments without risk of avascular necrosis.


Subject(s)
Fracture Fixation, Internal , Fractures, Comminuted , Patella , Humans , Fractures, Comminuted/surgery , Patella/surgery , Patella/injuries , Male , Female , Adult , Fracture Fixation, Internal/methods , Middle Aged , Bone Wires , Retrospective Studies , Tomography, X-Ray Computed , Young Adult , Bone Screws , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging
3.
PLoS One ; 19(5): e0302839, 2024.
Article in English | MEDLINE | ID: mdl-38696506

ABSTRACT

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Subject(s)
Bone Wires , Fracture Fixation, Internal , Fractures, Comminuted , Patella , Humans , Male , Female , Adult , Patella/surgery , Patella/injuries , Fractures, Comminuted/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies , Middle Aged , Range of Motion, Articular , Treatment Outcome , Fractures, Bone/surgery , Fracture Healing , Knee Joint/surgery , Knee Joint/physiopathology , Young Adult , Bone Screws , Suture Anchors
4.
Medicine (Baltimore) ; 103(18): e37979, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701293

ABSTRACT

Older children over 8 years old are at higher risk of elbow joint stiffness after treatment of supracondylar humeral fractures. The objective of this study was to improve the Slongo's external fixation system for treating supracondylar humeral fractures in older children. This would be achieved by increasing fixation strength and providing a theoretical basis through finite element analysis and mechanical testing. A 13-year-old female patient with a history of previous fracture was selected for CT data processing to create a three-dimensional model of the distal humerus fracture. Two internal fixation models were established, using the Slongo's external fixation method with Kirschner wire (Group A) and modifying the Slongo's external fixation (Kirschner wire tail fixation) (Group B). The fracture models were then subjected to mechanical loading analysis using Finite Element Analysis Abaqus 6.14 software to simulate separation, internal rotation, and torsion loads. A PVC humeral bone model was used to create a supracondylar fracture model, and the A and B internal fixation methods were applied separately. The anterior-posterior and torsional stresses were measured using the Bose Electroforce3510 testing system, followed by a comparative analysis. The finite element simulation results showed that under the same tensile, torsion, and inversion forces, the osteotomy model fixed with Kirschner wire at the distal end in Group B exhibited smaller tensile stress and deformation compared to the unfixed osteotomy model in Group A. This indicated that the fixation strength of Group B was superior to that of Group A. According to the test results of the Bose Electroforce3510 testing system, a simple linear regression analysis was conducted using SPSS software. The K values of rotation angle-torque tests and front and rear displacement-stress tests were calculated for Groups A and B, with Group B showing higher values than Group A. The results of this study supported the significantly enhanced biomechanical reliability and stability of fracture fixation in Group B, which utilized the modified Slongo's external fixation (Kirschner wire tail fixation). This optimized method provides a new choice for the clinical treatment of supracondylar humeral fractures in older children, backed by both clinical evidence and theoretical basis.


Subject(s)
External Fixators , Finite Element Analysis , Fracture Fixation , Humeral Fractures , Humans , Humeral Fractures/surgery , Female , Adolescent , Fracture Fixation/methods , Bone Wires , Biomechanical Phenomena , Tomography, X-Ray Computed
5.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702748

ABSTRACT

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Subject(s)
Bone Plates , Bone Wires , Fracture Fixation, Internal , Fractures, Bone , Metacarpal Bones , Metacarpal Bones/injuries , Metacarpal Bones/surgery , Humans , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Bone/surgery
6.
Dan Med J ; 71(5)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38704836

ABSTRACT

INTRODUCTION: Following surgical management of patella fractures, patients commonly report pain; difficulties with weight-bearing tasks such as walking, running and climbing stairs; and restrictions in quality of life. Recently, a locking plate system for surgical management of patella fractures has been introduced. To date, no studies have compared standard treatment with tension band wiring with locking plate fixation in a randomised study design. We aim to compare the one-year patient-reported Knee Injury and Osteoarthritis Outcome subscale scores (KOOS5-subscales) after standard care tension band fixation with locking plate fixation for patients with patella fractures. METHODS: This is a multicentre randomised and prospective clinical trial. A total of 122 patients will be included in the study, and the primary outcome will be the KOOS subscales at 12 months after surgery. CONCLUSIONS: Findings from the present study are expected to advance our understanding of outcome following surgical treatment of patella fractures. FUNDING: This study is funded, in part, by the Novo Nordisk Foundation, Denmark. CLINICALTRIALS: gov ID: NCT04891549.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Patella , Humans , Patella/injuries , Patella/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Prospective Studies , Female , Male , Treatment Outcome , Bone Wires , Adult , Randomized Controlled Trials as Topic , Middle Aged , Denmark , Quality of Life , Patella Fracture
7.
Port J Card Thorac Vasc Surg ; 31(1): 53-55, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38743519

ABSTRACT

INTRODUCTION: Minimally invasive repair of pectus carinatum (MIRPC) has been performed using the Abramson technique in which the bar that compresses the sternum is fixed with steel wires on the ribs. A 14-year-old patient underwent to a MIRPC using a sandwich technique in which two metallic bars fixed with bridges were implanted below the sternum under thoracoscopic vision, and another bar in a subcutaneous tunnel was implanted above. This technique has the potential to avoid specific problems related to the original technique like loosening of support for correction (broken wire), avoidance of induction of pectus excavatum or subcutaneous tissue adhesion.


Subject(s)
Pectus Carinatum , Humans , Pectus Carinatum/surgery , Adolescent , Male , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Thoracoscopy/methods , Thoracoscopy/instrumentation , Sternum/surgery , Sternum/abnormalities , Bone Wires , Treatment Outcome
8.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 583-587, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752245

ABSTRACT

Objective: To explore the mechanism, surgical method, and effectiveness of proximal phalangeal bone avulsion fracture caused by A2 circular trochlea injury of the flexor digitorum tendon. Methods: A retrospective analysis was conducted on the clinical data of 4 patients with proximal phalangeal bone avulsion fracture caused by A2 circular trochlea injury of flexor digitorum tendon admitted between May 2018 and September 2022. The patients were all male, the age ranged from 26 to 52 years, with an average of 33 years. The injured fingers included 1 case of middle finger and 3 cases of ring finger. The causes of injury were rock climbing of 2 cases and carrying heavy objects of 2 cases. Preoperative anteroposterior and lateral X-ray films and CT examination of the fingers showed a lateral avulsion fracture of the proximal phalanx, with a fracture block length of 15-22 mm and a width of 3-5 mm. The total active range of motion (TAM) of the injured finger before operation was (148.75±10.11)°. The grip strength of the middle and ring fingers was (15.50±2.88) kg, which was significantly lower than that of the healthy side (50.50±7.93) kg ( t=-8.280, P<0.001). The time from injury to operation was 2-7 days, with an average of 3.5 days. One Kirschner wire with a diameter of 1.0 mm was used for direct fixation through the fracture block, while two Kirschner wires with a diameter of 1.0 mm were used for compression fixation against the fracture block. The fracture healing was observed, and the TAM of the injured finger and the grip strength of the middle and ring fingers were measured. The finger function was evaluated according to the upper limb functional assessment trial standards of the Chinese Medical Association Hand Surgery Society. Results: The incisions all healed by first intention after operation. All patients were followed up 6-28 months, with an average of 19 months. X-ray films showed that all avulsion fractures of proximal phalanx reached bony union, and the healing time ranged from 4 to 8 weeks, with an average of 4.6 weeks. At last follow-up, the grip strength of the middle and ring fingers was (50.50±7.76) kg, which significantly improved when compared with preoperative one ( t=-8.440, P<0.001). The TAM of the injured finger reached (265.50±2.08)°, and there was a significant difference when compared with preoperative one ( t=-21.235, P<0.001). According to the upper limb functional assessment trial standards of the Chinese Medical Association Hand Surgery Society, the finger function was all evaluated as excellent in 4 cases. Conclusion: Using Kirschner wire fixation through bone blocks and external compression fixation of bone blocks for treating proximal phalangeal bone avulsion fracture caused by A2 circular trochlear injury of the flexor digitorum tendon can achieve good effectiveness.


Subject(s)
Bone Wires , Finger Injuries , Finger Phalanges , Fracture Fixation, Internal , Fractures, Avulsion , Tendon Injuries , Humans , Male , Adult , Fracture Fixation, Internal/methods , Fractures, Avulsion/surgery , Finger Phalanges/injuries , Finger Phalanges/surgery , Middle Aged , Tendon Injuries/surgery , Finger Injuries/surgery , Hand Strength , Treatment Outcome , Range of Motion, Articular , Fractures, Bone/surgery
9.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 613-617, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752250

ABSTRACT

Objective: To summarize the research progress in the treatment of distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children and to provide reference for clinical practice. Methods: The characteristics and treatment methods of transverse and comminuted DHMDJ fractures in children were summarized and analyzed by referring to relevant literature at home and abroad. Results: DHMDJ fractures in children are not uncommon clinically, with high fracture line position, multi-directional instability, difficult closed reduction in treatment, and easy to cause complications such as coronal and sagittal deformity of the elbow. The Kirschner wire technique was effective for DHMDJ fractures with the fracture line at the middle and low levels, but was prone to iatrogenic ulnar nerve injury. Elastic stable intramedullary nail is suitable for higher-position transverse DHMDJ fractures. However, this technique requires a second operation to remove the internal fixator, and may cause iatrogenic epiphysis plate injury in children. External fixator is a new way to treat DHMDJ fractures, and it can show satisfactory results for transverse and comminuted DHMDJ fractures. However, at present, there are few relevant studies, and most of them focus on biomechanical studies, and the efficacy lacks high-quality clinical research support. Conclusion: The ultimate goal of DHMDJ fracture treatment in children is to restore the anatomical alignment of the fracture and prevent the loss of reduction. The choice of internal fixator depends on the location of the fracture line and the shape of the fracture to provide personalized treatment.


Subject(s)
Fracture Fixation, Internal , Humeral Fractures , Humans , Child , Humeral Fractures/surgery , Fracture Fixation, Internal/methods , Bone Wires , External Fixators , Diaphyses/injuries , Fractures, Comminuted/surgery , Fracture Fixation, Intramedullary/methods , Treatment Outcome , Bone Plates , Bone Nails , Internal Fixators , Child, Preschool , Elbow Joint/surgery , Fracture Healing
10.
PLoS One ; 19(5): e0296149, 2024.
Article in English | MEDLINE | ID: mdl-38748687

ABSTRACT

BACKGROUND: The recommendation on whether to bury or expose the Kirschner wire (K-wire) for the management of fractures has still been controversial with inconsistent results in the published studies due to the potential issue associated with exposed K-wire is the heightened risk of infection, as it comes into direct contact with the external environment and air. This study aims to summarize the specific outcomes between buried and exposed K-wire for the management of hand and forearm fractures. METHODS: We conducted relevant literature searches on Europe PMC, Medline, Scopus, and Cochrane Library databases using specific keywords. This investigation focuses on individuals of any age diagnosed with hand or forearm fractures who underwent surgery involving Kirschner wire (K-wire) fixation. It examines the comparison between buried and exposed K-wire fixation, emphasizing primary outcome pin infection, along with secondary outcomes such as early pin removal, days to pin removal, and surgical duration. The study includes observational studies (cohort/case-control) or randomized clinical trials (RCTs). The results of continuous variables were pooled into the standardized mean difference (SMD), while dichotomous variables were pooled into odds ratio (OR) along with 95% confidence intervals using random-effect models. The quality of included studies was assessed with Cochrane Collaborations, Risk of Bias version 2 (RoB v2). RESULTS: A total of 11 studies were included. Our pooled analysis revealed that buried K-wire was associated with a lower risk of pin site infection [RR 0.49 (95% CI 0.36-0.67), p < 0.00001, I2 = 0%] and 33.85 days longer duration until pin removal [MD 33.85 days (95% CI 18.68-49.02), p < 0.0001, I2 = 99%] when compared with exposed K-wire. However, the duration of surgery was 9.98 minutes significantly longer in the buried K-wire [MD 6.98 minutes (95% CI 2.19-11.76), p = 0.004, I2 = 42%] with no significant difference in the early pin removal rate [RR 0.73 (95% CI 0.36-1.45), p = 0.37, I2 = 0%]. Further regression analysis revealed that sample size, age, sex, and duration of follow-up did not affect those relationships. CONCLUSION: Buried K-wire may offer benefits in reducing the infection rate with a longer duration until pin removal. However, further RCTs with larger sample sizes are still needed to confirm the results of our study.


Subject(s)
Bone Wires , Humans , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Fractures, Bone/surgery , Hand Bones/surgery , Hand Bones/injuries , Forearm Injuries/surgery
11.
Cir Cir ; 92(2): 211-218, 2024.
Article in English | MEDLINE | ID: mdl-38782385

ABSTRACT

OBJECTIVES: The aim of the study was to investigate the clinical effect of stainless-steel wire fixation on the early mouth-opening movement of an intracapsular fracture involving the condylar process. MATERIALS AND METHODS: In this study, patients who underwent mandibular condylar intracapsular fracture surgery in our hospital from 2012 to 2020 were selected as research subjects. A total of 44 patients received steel wire internal fixation treatment, 32 patients received titanium plate-and-nail rigid internal fixation, and 28 patients underwent conservative non-surgical treatment. RESULTS: For the patients in the stainless-steel wire group, the degree of mouth opening reached normal levels of 3.7 cm approximately 10 days after surgery. The recovery time for the patients in the titanium plate-and-nail rigid internal-fixation group was 21 days, while the patients in the conservative treatment group needed 60 days to recover. CONCLUSION: The treatment of fixation with a stainless-steel wire for intracapsular condylar fracture reduced the time taken to perform mouth-opening exercises and improved the recovery rate of patients.


OBJETIVO: Explorar el efecto clínico de la fijación de alambre de acero inoxidable en el movimiento temprano de apertura de la boca en la fractura interna del cóndilo. MÉTODO: Este estudio seleccionó a pacientes que se sometieron a cirugía de fractura intracapsular de cóndilo en nuestro hospital de 2012 a 2020 como sujetos de investigación. Un total de 44 pacientes recibieron tratamiento de fijación interna de alambre de acero, 32 recibieron placa de titanio y fijación interna con clavos, y 28 recibieron tratamiento conservador no quirúrgico. RESULTADOS: En los pacientes del grupo de alambre de acero inoxidable, alrededor de 10 días después de la cirugía el grado de apertura de la boca alcanzó un valor normal de 3.7 cm. El tiempo de recuperación de los pacientes en el grupo de fijación interna con clavos y placa de titanio fue de 21 días, mientras que los pacientes en el grupo de tratamiento conservador tardaron 60 días en recuperarse. CONCLUSIONES: La fijación con alambre de acero inoxidable para el tratamiento de la fractura intracapsular del cóndilo acorta el tiempo hasta la apertura de la boca y mejora la tasa de recuperación de los pacientes.


Subject(s)
Bone Plates , Bone Wires , Fracture Fixation, Internal , Mandibular Condyle , Mandibular Fractures , Stainless Steel , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Mandibular Fractures/surgery , Mandibular Condyle/injuries , Mandibular Condyle/surgery , Male , Female , Adult , Middle Aged , Titanium , Range of Motion, Articular , Bone Nails , Young Adult , Retrospective Studies
12.
BMJ Case Rep ; 17(5)2024 May 22.
Article in English | MEDLINE | ID: mdl-38782442

ABSTRACT

The treatment of acute heel pad avulsion differs significantly from managing other soft tissue injuries due to its unique soft tissue structure. This case report outlines a scenario involving a male in his 20s who suffered heel pad avulsion without a calcaneal fracture but with an ipsilateral medial malleolus fracture after a twisting injury to the ankle caused by a road traffic accident. Immediate action was taken within 24 hours of the injury, involving thorough debridement of the wound, fixation to the calcaneum using multiple K-wires, primary suturing and internal fixation of the medial malleolus with two cannulated cancellous screws. Postoperative care included PRP (platelet-rich plasma) injections into the wound twice, removal of K-wires after 6 weeks and allowing walking with full weight bearing after 8 weeks. A year later, the wound had completely healed, and the patient was comfortably walking pain-free with full weight-bearing capabilities.


Subject(s)
Bone Wires , Fracture Fixation, Internal , Platelet-Rich Plasma , Humans , Male , Fracture Fixation, Internal/methods , Heel/injuries , Soft Tissue Injuries/therapy , Debridement/methods , Calcaneus/injuries , Young Adult , Foot Injuries/therapy , Foot Injuries/surgery , Treatment Outcome
13.
J Hand Surg Asian Pac Vol ; 29(3): 179-183, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38726491

ABSTRACT

Background: Bennett fractures are traditionally fixed with percutaneous K-wires from dorsal to volar, or with a volar to dorsal screw via a volar open approach. While volar to dorsal screw fixation is biomechanically advantageous, an open approach requires extensive soft tissue dissection, thus increasing morbidity. This study aims to investigate the practicality and safety of Bennett fracture fixation using a percutaneous, volar to dorsal screw, particularly with regard to the median nerve and its motor branch during wire and screw insertion. Methods: Fifteen fresh frozen forearm and hand specimens were obtained from the University of Auckland human cadaver laboratory. A guidewire is placed under image intensifier from volar to dorsal with the thumb held in traction, abduction and pronation. The wire is passed through the skin volarly under image intensifier, then the median nerve is dissected from the carpal tunnel and the motor branch of the median nerve (MBMN) is dissected from its origin to where it supplies the thenar musculature. The distance between the K-wire to the MBMN is measured. Results: In 14 of 15 specimens, the wire was superficial and radial to the carpal tunnel. The mean distance to the origin of the MBMN is 6.2 mm (95% CI 4.1-8.3) with the closest specimen 1 mm away. The mean closest distance the wire gets to any part of the MBMN is 3.7 mm (95% CI 1.6-5.8); in two specimens, the wire was through the MBMN. Conclusions: Wire placement, although done under image intensifier, is subject to significant variation in exiting location. While research has shown the thenar portal in arthroscopic thumb surgery is safe, our guidewire needs to exit further ulnar to capture the Bennett fracture fragment, placing the MBMN at risk. This cadaveric study has demonstrated the proposed technique is unsafe for use.


Subject(s)
Bone Screws , Cadaver , Fracture Fixation, Internal , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/adverse effects , Bone Screws/adverse effects , Bone Wires/adverse effects , Fracture Dislocation/surgery , Fracture Dislocation/diagnostic imaging , Median Nerve/injuries , Median Nerve/surgery , Fractures, Bone/surgery
14.
Sci Rep ; 14(1): 9999, 2024 05 01.
Article in English | MEDLINE | ID: mdl-38693300

ABSTRACT

Although tension band wiring (TBW) is popular and recommended by the AO group, the high rate of complications such as skin irritation and migration of the K-wires cannot be ignored. Ding's screw tension band wiring (DSTBW) is a new TBW technique that has shown positive results in the treatment of other fracture types. The objective of this study was to evaluate the stability of DSTBW in the treatment of olecranon fractures by biomechanical testing. We conducted a Synbone biomechanical model by using three fixation methods: DSTBW, intramedullary screw and tension band wiring (IM-TBW), and K-wire TBW, were simulated to fix the olecranon fractures. We compared the mechanical stability of DSTBW, IM-TBW, and TBW in the Mayo Type IIA olecranon fracture Synbone model using a single cycle loading to failure protocol or pullout force. During biomechanical testing, the average fracture gap measurements were recorded at varying flexion angles in three different groups: TBW, IM-TBW, and DSTBW. The TBW group exhibited measurements of 0.982 mm, 0.380 mm, 0.613 mm, and 1.285 mm at flexion angles of 0°, 30°, 60°, and 90° respectively. The IM-TBW group displayed average fracture gap measurements of 0.953 mm, 0.366 mm, 0.588 mm, and 1.240 mm at each of the corresponding flexion angles. The DSTBW group showed average fracture gap measurements of 0.933 mm, 0.358 mm, 0.543 mm, and 1.106 mm at the same flexion angles. No specimen failed in each group during the cyclic loading phase. Compared with the IM-TBW and TBW groups, the DSTBW group showed significant differences in 60° and 90° flexion angles. The mean maximum failure load was 1229.1 ± 110.0 N in the DSTBW group, 990.3 ± 40.7 N in the IM-TBW group, and 833.1 ± 68.7 N in the TBW group. There was significant difference between each groups (p < 0.001).The average maximum pullout strength for TBW was measured at 57.6 ± 5.1 N, 480.3 ± 39.5 N for IM-TBW, and 1324.0 ± 43.8 N for DSTBW. The difference between maximum pullout strength of both methods was significant to p < 0.0001. DSTBW fixation provides more stability than IM-TBW and TBW fixation models for olecranon fractures.


Subject(s)
Bone Screws , Bone Wires , Fracture Fixation, Internal , Olecranon Process , Humans , Olecranon Process/injuries , Olecranon Process/surgery , Biomechanical Phenomena , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Ulna Fractures/surgery , Ulna Fractures/physiopathology , Fractures, Bone/surgery , Olecranon Fracture
15.
Sci Rep ; 14(1): 12569, 2024 05 31.
Article in English | MEDLINE | ID: mdl-38822126

ABSTRACT

We have developed a novel osteosynthesis plate with bone union detection using a wire's natural frequency (BUDWF) to provide the quantitative result of bone union detection. The concept for detecting bone union is measuring the rate of frequency change. The frequency is measured from sound generated from the wire attached to a modified plate. The plate is modified from a Syncera ADLER B0409.10 and attached with 0.3 mm diameter 316L stainless steel wire. The sound generation mechanism was created by PEEK and installed on the plate to generate the sound. The preliminary experiments were conducted on a Sawbones tibia composite mimic. We used the cut Sawbones to create fracture samples with a 0, 0.5, 1-, 2-, and 5-mm gap representing the fractured bone with different gap sizes and prepared uncut Sawbones as a union sample. These samples were tested five times, and the sound was recorded from a condenser microphone and analyzed. We found that the BUDWF can differentiate samples with a fracture gap above 2 mm from the union sample, as the differences in the rates of frequency change between samples with a fracture gap above 2 mm and union samples were statistically significant. However, there was a limitation that the BUDWF plate was still unable to differentiate the 0 mm fracture gap and the union sample in this study.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Humans , Bone Wires , Fracture Healing
16.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
17.
Medicina (Kaunas) ; 60(5)2024 May 09.
Article in English | MEDLINE | ID: mdl-38792971

ABSTRACT

Background and Objectives: Patella baja is a common complication after operative treatment for patellar fracture. This study aimed to investigate (1) the serial changes in patellar height and (2) the potential predictive factors for patellar height changes after tension band wiring (TBW) for patellar fractures. Materials and Methods: Forty-one patients who underwent TBW for patellar fracture between March 2019 and September 2022 were enrolled. To identify serial changes in patellar height, modified Blackburne-Peel index (mBPI) was assessed at just after surgery, at 3 months, at 6 months, at 1 year and at the final follow-up. Multiple regression analysis was conducted to identify factors correlated with mBPI difference between the contralateral side (considered as preoperative status) and injured side. Results: The postoperative mBPI exhibited a decline over time (mean mBPI immediately post operation/3 months/6 months/1 year/final follow-up: 0.69/0.63/0.63/0.62/0.61) Specifically, mBPI showed a significant reduction immediately post operation to 3 months (p < 0.001), although comparisons at other time points did not reveal significant differences. A lower position of the fracture was associated with a decrease in patellar height after surgery. Conclusions: Patellar height was mainly decreased from immediately post operation to 3 months. A fracture in a lower position of associated with decreased patellar height after the TBW of the transverse patellar fracture.


Subject(s)
Fractures, Bone , Patella , Humans , Patella/injuries , Male , Female , Adult , Fractures, Bone/surgery , Middle Aged , Retrospective Studies , Bone Wires/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects
18.
Zhongguo Gu Shang ; 37(4): 399-405, 2024 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-38664212

ABSTRACT

OBJECTIVE: To compare screw versus Kirschner wire fixation in the treatment of lateral humeral condyle fractures in children. METHODS: A systematic search was conducted in PubMed, Embase, the Cochrane library, Web of Science, China National Knowledge Internet(CNKI), Wanfang Datebase from in ception to February 2022. Studies comparing screws and Kirschner wire fixation in the treatment of lateral humeral condyle fractures in children were included. Outcome measures included and excluded by a set of inclusion and exclusion criteria and evaluated for their quality, their excellent and good rate of fracture healing, malunion, delayed union or nonunion, infection, limitation of elbow flexion or extension(>10°) were extracted and analyzed using software Rev Man 5.3. RESULTS: A total of 9 retrospective studies involving 647 patients were included, with 255 patients in the screw fixation group(including screw combined with Kirschner wire) and 392 patients in the Kirschner wire fixation group. Meta analysis showed the following:infection rate in the screw group was significantly lower than that in the Kirschner wire group[OR=0.22, 95%CI(0.09, 0.56), P=0.001]. There were no significant differences between the 2 groups in excellent and good rate of fracture healing, malunion rate(P>0.05). Subgroup analysis showed that infection rate in the screw-only group was significantly lower than that in the Kirschner wire group[OR=0.18, 95%CI(0.05, 0.65), P=0.009]. CONCLUSION: For lateral humeral condyle fractures, Screw fixation alone had a lower infection rate than kirschner wire fixation and screw combined with Kirschner wire fixation. There were no significant differences in the excellent and good rate of fracture healing, malunion. In terms of postoperative efficacy and safety of internal fixation, orthopaedic surgeons are more likely to recommend screws for fixation of lateral humeral condyle fractures in children.


Subject(s)
Bone Screws , Bone Wires , Fracture Fixation, Internal , Humeral Fractures , Humans , Fracture Fixation, Internal/methods , Child , Humeral Fractures/surgery , Humeral Fractures, Distal
19.
Int Orthop ; 48(6): 1501-1506, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38561523

ABSTRACT

PURPOSE: There is no consensus on the optimal treatment of bony mallet finger in the paediatric population due to a lack of studies in children. The Ishiguro technique is simple and less invasive, and treatment with K-wire fixation seems to provide better results for extension lag in bony mallet finger according to the literature. A retrospective cross-sectional study with long-term follow-up was performed to evaluate the functional and clinical outcomes of this method in children. Preoperative and intraoperative predictors of outcome were investigated. METHODS: From June to December 2022, we evaluated 95 children who underwent extension K-wire block from 2002 to 2012. Eighty-four children were included (mean age 14.8 ± 1.68 years) for a mean long-term follow-up of 11.6 ± 2.3 (8-16) years. Clinical and radiographic features were assessed. Pain and functional outcomes were assessed using Crawford criteria, range of motion (ROM) at the distal interphalangeal joint (DIPJ), loss of extension, and VAS scale. Univariate and multivariate regressions were used to assess which variables might predict the worst outcomes at long-term follow-up. RESULTS: Bone union and pain relief were always achieved. There were no complaints of potential growth impairment or nail deformity. 82.1% of patients showed excellent and good results. Fifteen patients had fair results. CONCLUSIONS: Although there are currently no significant differences between surgery and orthosis in adults, the Ishiguro technique is more effective in children when it comes to outcomes in the treatment of mallet fingers. A high percentage of excellent and good results were achieved, and no epiphyseal damage or nail deformity was reported. A strong and significant correlation was found between the worst outcomes and either delayed treatment time or excessive flexion angle.


Subject(s)
Bone Wires , Range of Motion, Articular , Humans , Retrospective Studies , Female , Male , Adolescent , Follow-Up Studies , Child , Cross-Sectional Studies , Range of Motion, Articular/physiology , Treatment Outcome , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Finger Injuries/surgery , Finger Injuries/therapy , Finger Joint/surgery , Finger Joint/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...