Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52.353
Filter
1.
Article in English | MEDLINE | ID: mdl-38727533

ABSTRACT

Preoperative calculations showed that the 9-mm inlet, 6-mm outlet, 25-cc pump chambers and 65-73 bpm would be optimal for a 5-year-old patient suffering from restrictive cardiomyopathy, with a body surface area of 0.59 m2 (1.5 L/min flow for a cardiac index of 2.5). After re-sternotomy and standard bicaval cannulation for cardiopulmonary bypass, the procedure was performed under normothermic conditions and on the beating heart. Biventricular support was established with the Berlin Heart Excor using biatrial cannulation. For left atrial cannulation, induced ventricular fibrillation was used. The 9-mm inlet cannulas were inserted into the left and right atria, respectively. The 6-mm outlet cannulas were implanted using 8-mm interposition vascular grafts for the aorta and the main pulmonary artery, respectively. Cannulas were tunnelled through the epigastric space, with systems crossing outside of the body. The 25-cc chambers were used for both right ventricular assist device and left ventricular assist device support, which subsequently showed full emptying and filling.


Subject(s)
Cardiomyopathy, Restrictive , Heart-Assist Devices , Humans , Cardiomyopathy, Restrictive/surgery , Cardiomyopathy, Restrictive/diagnosis , Male , Child, Preschool , Heart Atria/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/instrumentation , Heart Failure/surgery , Prosthesis Implantation/methods
2.
J Radiol Prot ; 44(2)2024 May 28.
Article in English | MEDLINE | ID: mdl-38722296

ABSTRACT

The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.


Subject(s)
Occupational Exposure , Radiation Dosage , Humans , Occupational Exposure/analysis , Child , Cardiac Catheterization , Radiation Protection , Lens, Crystalline/radiation effects , Radiography, Interventional , Radiation Exposure/analysis
3.
JACC Cardiovasc Interv ; 17(9): 1091-1102, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38749588

ABSTRACT

BACKGROUND: Invasive CFT is the gold standard for diagnosing coronary vasomotor dysfunction in patients with ANOCA. Most institutions recommend only testing the left coronary circulation. Therefore, it is unknown whether testing multiple coronary territories would increase diagnostic yield. OBJECTIVES: The aim of this study was to evaluate the diagnostic yield of multivessel, compared with single-vessel, invasive coronary function testing (CFT) in patients with angina and nonobstructive coronary arteries (ANOCA). METHODS: Multivessel CFT was systematically performed in patients with suspected ANOCA. Vasoreactivity testing was performed using acetylcholine provocation in the left (20 to 200 µg) and right (20 to 80µg) coronary arteries. A pressure-temperature sensor guidewire was used for coronary physiology assessment in all three epicardial vessels. RESULTS: This multicenter study included a total of 228 vessels from 80 patients (57.8 ± 11.8 years of age, 60% women). Compared with single-vessel CFT, multivessel testing resulted in more patients diagnosed with coronary vasomotor dysfunction (86.3% vs 68.8%; P = 0.0005), coronary artery spasm (60.0% vs 47.5%; P = 0.004), and CMD (62.5% vs 36.3%; P < 0.001). Coronary artery spasm (n = 48) predominated in the left coronary system (n = 38), though isolated right coronary spasm was noted in 20.8% (n = 10). Coronary microvascular dysfunction (CMD), defined by abnormal index of microcirculatory resistance and/or coronary flow reserve, was present 62.5% of the cohort (n = 50). Among the cohort with CMD, 27 patients (33.8%) had 1-vessel CMD, 15 patients (18.8%) had 2-vessel CMD, and 8 patients (10%) had 3-vessel CMD. CMD was observed at a similar rate in the territories supplied by all 3 major coronary vessels (left anterior descending coronary artery = 36.3%, left circumflex coronary artery = 33.8%, right coronary artery = 31.3%; P = 0.486). CONCLUSIONS: Multivessel CFT resulted in an increased diagnostic yield in patients with ANOCA compared with single-vessel testing. The results of this study suggest that multivessel CFT has a role in the management of patients with ANOCA.


Subject(s)
Acetylcholine , Angina Pectoris , Coronary Artery Disease , Coronary Circulation , Coronary Vasospasm , Coronary Vessels , Predictive Value of Tests , Vasodilator Agents , Humans , Female , Male , Middle Aged , Aged , Coronary Vessels/physiopathology , Coronary Vessels/diagnostic imaging , Vasodilator Agents/administration & dosage , Coronary Vasospasm/physiopathology , Coronary Vasospasm/diagnosis , Acetylcholine/administration & dosage , Angina Pectoris/physiopathology , Angina Pectoris/diagnosis , Angina Pectoris/etiology , Coronary Artery Disease/physiopathology , Coronary Artery Disease/diagnosis , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Cardiac Catheterization , Coronary Angiography , Reproducibility of Results , Vasodilation , Vasoconstriction
4.
Braz J Cardiovasc Surg ; 39(4): e20230237, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748975

ABSTRACT

Transcatheter mitral valve-in-valve is an alternative to high-risk reoperation on a failing bioprosthesis. It entails specific challenges such as left ventricular outflow tract obstruction. We propose a patient-specific augmented imaging based on preoperative planning to assist the procedure. Valve-in-valve simulation was performed to represent the optimal level of implantation and the neo-left ventricular outflow tract. These data were combined with intraoperative images through a real-time 3D/2D registration tool. All data were collected retrospectively on one case (pre and per-procedure imaging). We present for the first time an intraoperative guidance tool in transcatheter mitral valve-in-valve procedure.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Surgery, Computer-Assisted , Humans , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Surgery, Computer-Assisted/methods , Cardiac Catheterization/methods , Bioprosthesis , Retrospective Studies , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Male
5.
PLoS One ; 19(5): e0298727, 2024.
Article in English | MEDLINE | ID: mdl-38768104

ABSTRACT

Cardiac output (CO) is one of the primary prognostic factors evaluated during the follow-up of patients treated for pulmonary hypertension (PH). It is recommended that it be measured using the thermodilution technique during right heart catheterization. The difficulty to perform iterative invasive measurements on the same individual led us to consider a non-invasive option. The aims of the present study were to assess the agreement between CO values obtained using bioreactance (Starling™ SV) and thermodilution, and to evaluate the ability of the bioreactance monitor to detect patients whose CO decreased by more than 15% during follow-up and, accordingly, its usefulness for patient monitoring. A prospective cohort study evaluating the performance of the Starling™ SV monitor was conducted in patients with clinically stable PH. Sixty patients referred for hemodynamic assessment were included. CO was measured using both the thermodilution technique and bioreactance during two follow-up visits. A total of 60 PH patients were included. All datasets were available at the baseline visit (V0) and 50 of them were usable during the follow-up visit (V1). Median [IQR] CO was 4.20 l/min [3.60-4.70] when assessed by bioreactance, and 5.30 l/min [4.57-6.20] by thermodilution (p<0.001). The Spearman correlation coefficient was 0.51 [0.36-0.64], and the average deviation on Bland-Altman plot was -1.25 l/min (95% CI [-1.48-1.01], p<0.001). The ability of the monitor to detect a variation in CO of more than 15% between two follow-up measurements, when such variation existed using thermodilution, was insufficient for clinical practice (AUC = 0.54, 95% CI [0.33-0.75]).


Subject(s)
Cardiac Output , Hypertension, Pulmonary , Thermodilution , Humans , Cardiac Output/physiology , Female , Male , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/diagnosis , Middle Aged , Thermodilution/methods , Follow-Up Studies , Prospective Studies , Aged , Reproducibility of Results , Monitoring, Physiologic/methods , Cardiac Catheterization , Adult
6.
Circ Cardiovasc Interv ; 17(5): e013844, 2024 May.
Article in English | MEDLINE | ID: mdl-38771911

ABSTRACT

BACKGROUND: The Murray law-based quantitative flow ratio (µFR) is an emerging technique that requires only 1 projection of coronary angiography with similar accuracy to quantitative flow ratio (QFR). However, it has not been validated for the evaluation of noninfarct-related artery (non-IRA) in acute myocardial infarction (AMI) settings. Therefore, our study aimed to evaluate the diagnostic accuracy of µFR and the safety of deferring non-IRA lesions with µFR >0.80 in the setting of AMI. METHODS: µFR and QFR were analyzed for non-IRA lesions of patients with AMI enrolled in the FRAME-AMI trial (Fractional Flow Reserve Versus Angiography-Guided Strategy for Management of Non-Infarction Related Artery Stenosis in Patients With Acute Myocardial Infarction), consisting of fractional flow reserve (FFR)-guided percutaneous coronary intervention and angiography-guided percutaneous coronary intervention groups. The diagnostic accuracy of µFR was compared with QFR and FFR. Patients were classified by the non-IRA µFR value of 0.80 as a cutoff value. The primary outcome was a vessel-oriented composite outcome, a composite of cardiac death, non-IRA-related myocardial infarction, and non-IRA-related repeat revascularization. RESULTS: µFR and QFR analyses were feasible in 443 patients (552 lesions). µFR showed acceptable correlation with FFR (R=0.777; P<0.001), comparable C-index with QFR to predict FFR ≤0.80 (µFR versus QFR: 0.926 versus 0.961, P=0.070), and shorter total analysis time (mean, 32.7 versus 186.9 s; P<0.001). Non-IRA with µFR >0.80 and deferred percutaneous coronary intervention had a significantly lower risk of vessel-oriented composite outcome than non-IRA with performed percutaneous coronary intervention (3.4% versus 10.5%; hazard ratio, 0.37 [95% CI, 0.14-0.99]; P=0.048). CONCLUSIONS: In patients with multivessel AMI, µFR of non-IRA showed acceptable diagnostic accuracy comparable to that of QFR to predict FFR ≤0.80. Deferred non-IRA with µFR >0.80 showed a lower risk of vessel-oriented composite outcome than revascularized non-IRA. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02715518.


Subject(s)
Coronary Angiography , Coronary Artery Disease , Coronary Vessels , Fractional Flow Reserve, Myocardial , Myocardial Infarction , Percutaneous Coronary Intervention , Predictive Value of Tests , Humans , Male , Female , Aged , Middle Aged , Treatment Outcome , Myocardial Infarction/physiopathology , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Percutaneous Coronary Intervention/adverse effects , Reproducibility of Results , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Risk Factors , Coronary Stenosis/physiopathology , Coronary Stenosis/therapy , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/diagnosis , Cardiac Catheterization , Prospective Studies
7.
Lancet Digit Health ; 6(6): e407-e417, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38789141

ABSTRACT

BACKGROUND: With increasing numbers of patients and novel drugs for distinct causes of systolic and diastolic heart failure, automated assessment of cardiac function is important. We aimed to provide a non-invasive method to predict diagnosis of patients undergoing cardiac MRI (cMRI) and to obtain left ventricular end-diastolic pressure (LVEDP). METHODS: For this modelling study, patients who had undergone cardiac catheterisation at University Hospital Heidelberg (Heidelberg, Germany) between July 15, 2004 and March 16, 2023, were identified, as were individual left ventricular pressure measurements. We used existing patient data from routine cardiac diagnostics. From this initial group, we extracted patients who had been diagnosed with ischaemic cardiomyopathy, dilated cardiomyopathy, hypertrophic cardiomyopathy, or amyloidosis, as well as control individuals with no structural phenotype. Data were pseudonymised and only processed within the university hospital's AI infrastructure. We used the data to build different models to predict either demographic (ie, AI-age and AI-sex), diagnostic (ie, AI-coronary artery disease and AI-cardiomyopathy [AI-CMP]), or functional parameters (ie, AI-LVEDP). We randomly divided our datasets via computer into training, validation, and test datasets. AI-CMP was not compared with other models, but was validated in a prospective setting. Benchmarking was also done. FINDINGS: 66 936 patients who had undergone cardiac catheterisation at University Hospital Heidelberg were identified, with more than 183 772 individual left ventricular pressure measurements. We extracted 4390 patients from this initial group, of whom 1131 (25·8%) had been diagnosed with ischaemic cardiomyopathy, 1064 (24·2%) had been diagnosed with dilated cardiomyopathy, 816 (18·6%) had been diagnosed with hypertrophic cardiomyopathy, 202 (4·6%) had been diagnosed with amyloidosis, and 1177 (26·7%) were control individuals with no structural phenotype. The core cohort only included patients with cardiac catherisation and cMRI within 30 days, and emergency cases were excluded. AI-sex was able to predict patient sex with areas under the receiver operating characteristic curves (AUCs) of 0·78 (95% CI 0·77-0·78) and AI-age was able to predict patient age with a mean absolute error of 7·86 years (7·77-7·95), with a Pearson correlation of 0·57 (95% CI 0·56-0·57). The AUCs for the classification tasks ranged between 0·82 (95% CI 0·79-0·84) for ischaemic cardiomyopathy and 0·92 (0·91-0·94) for hypertrophic cardiomyopathy. INTERPRETATION: Our AI models could be easily integrated into clinical practice and provide added value to the information content of cMRI, allowing for disease classification and prediction of diastolic function. FUNDING: Informatics for Life initiative of the Klaus-Tschira Foundation, German Center for Cardiovascular Research, eCardiology section of the German Cardiac Society, and AI Health Innovation Cluster Heidelberg.


Subject(s)
Magnetic Resonance Imaging , Humans , Male , Female , Middle Aged , Aged , Magnetic Resonance Imaging/methods , Artificial Intelligence , Germany , Ventricular Pressure/physiology , Cardiac Catheterization , Adult , Diastole , Ventricular Function, Left/physiology
9.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38749587

ABSTRACT

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Subject(s)
Balloon Valvuloplasty , Cardiac Catheterization , Heart Valve Prosthesis Implantation , Palliative Care , Stents , Tetralogy of Fallot , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/physiopathology , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Infant , Treatment Outcome , Age Factors , Child, Preschool , Child , Adult , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Infant, Newborn , Young Adult , Cardiac Surgical Procedures/adverse effects , Risk Factors , Female , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Male , Hemodynamics , Middle Aged , Recovery of Function
10.
Sci Rep ; 14(1): 11745, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38778204

ABSTRACT

Preclinical in vivo evaluation is an essential step in the progression of new cardiac devices into patient use, with studies predominantly performed in the domestic sheep model. A growing area of interest in cardiac device development is transcatheter mitral valve replacement (TMVR). Clinically, multimodal imaging, or computed tomography (CT) and echocardiography (echo) are used extensively to preoperatively determine mitral valve morphology prior to an intervention, but there is no description on how these modalities can be implemented to support preclinical studies. The purpose of this study is to apply clinically relevant CT and echo acquisition and assessment techniques to a large group of naive research sheep in order to analyze and report modality-related effects on mitral valve dimensional reference intervals in the sheep model. To this end, fifty-five adult domestic sheep underwent preoperative CT and echo exams and resultant images were analyzed using a landmark-based multiplanar measurement protocol and compiled into a master dataset for statistical analysis. We found moderate agreement between CT and echo-derived measurements of the mitral valve in sheep and propose the first clinically-relevant dimensional indices for the sheep's naive mitral valve which can be used to guide future studies evaluating novel TMVR devices. This study is the first of its kind in proposing a reproducible method for detailed examination of the mitral valve in the sheep model using clinically-relevant multimodal imaging. As in patients, CT and echo can reveal accurate native mitral valve dimensions in the sheep prior to preclinical TMVR studies.


Subject(s)
Echocardiography , Heart Valve Prosthesis Implantation , Mitral Valve , Multimodal Imaging , Tomography, X-Ray Computed , Animals , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Sheep , Heart Valve Prosthesis Implantation/methods , Echocardiography/methods , Tomography, X-Ray Computed/methods , Multimodal Imaging/methods , Sheep, Domestic , Cardiac Catheterization/methods
11.
PLoS One ; 19(5): e0301939, 2024.
Article in English | MEDLINE | ID: mdl-38781278

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has garnered interest as a viable alternative to the traditional surgical mitral valve replacement (SMVR) for high-risk patients requiring redo operations. This study aims to evaluate the association of TMVR with selected clinical and financial outcomes. METHODS: Adults undergoing isolated redo mitral valve replacement were identified in the 2016-2020 Nationwide Readmissions Database and categorized into TMVR or SMVR cohorts. Various regression models were developed to assess the association between TMVR and in-hospital mortality, as well as additional secondary outcomes. Transseptal and transapical catheter-based approaches were also compared in relation to study endpoints. RESULTS: Of an estimated 7,725 patients, 2,941 (38.1%) underwent TMVR. During the study period, the proportion of TMVR for redo operations increased from 17.8% to 46.7% (nptrend<0.001). Following adjustment, TMVR was associated with similar odds of in-hospital mortality (AOR 0.82, p = 0.48), but lower odds of stroke (AOR 0.44, p = 0.001), prolonged ventilation (AOR 0.43, p<0.001), acute kidney injury (AOR 0.61, p<0.001), and reoperation (AOR 0.29, p = 0.02). TMVR was additionally correlated with shorter postoperative length of stay (pLOS; ß -0.98, p<0.001) and reduced costs (ß -$10,100, p = 0.002). Additional analysis demonstrated that the transseptal approach had lower adjusted mortality (AOR 0.44, p = 0.02), shorter adjusted pLOS (ß -0.43, p<0.001), but higher overall costs (ß $5,200, p = 0.04), compared to transapical. CONCLUSIONS: In this retrospective cohort study, we noted TMVR to yield similar odds of in-hospital mortality as SMVR, but fewer complications and reduced healthcare expenditures. Moreover, transseptal approaches were associated with lower adjusted mortality, shorter pLOS, but higher cost, relative to the transapical. Our findings suggest that TMVR represent a cost-effective and safe treatment modality for patients requiring redo mitral valve procedures. Nevertheless, future studies examining long-term outcomes associated with SMVR and TMVR in redo mitral valve operations, are needed.


Subject(s)
Heart Valve Prosthesis Implantation , Hospital Mortality , Mitral Valve , Humans , Male , Female , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/economics , Heart Valve Prosthesis Implantation/adverse effects , Aged , Mitral Valve/surgery , Middle Aged , Reoperation/statistics & numerical data , Cardiac Catheterization/methods , Cardiac Catheterization/economics , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Retrospective Studies , Length of Stay , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Postoperative Complications/etiology , Aged, 80 and over , United States/epidemiology
12.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38742523

ABSTRACT

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Italy/epidemiology , Aged, 80 and over , Patient Readmission/statistics & numerical data , Treatment Failure , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Annuloplasty/adverse effects , Treatment Outcome , Time Factors , Risk Factors , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/surgery
13.
Ital J Pediatr ; 50(1): 100, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760836

ABSTRACT

BACKGROUND: The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project aims to improve knowledge on the effects of medical exposure to ionizing radiation (IR) received during childhood. One of its objectives is to build a consolidated European cohort of pediatric patients who have undergone cardiac catheterization (Cath) procedures, with the goal of enhancing the assessment of long-term radiation-associated cancer risk. The purpose of our study is to provide a detailed description of the Italian cohort contributing to the HARMONIC project, including an analysis of cumulative IR exposure, reduction trend over the years and an overview of the prospective collection of biological samples for research in this vulnerable population. METHODS: In a single-center retrospective cohort study, a total of 584 patients (323 males) with a median age of 6 (2-13) years, referred at the Pediatric Cardiology in Niguarda Hospital from January 2015 to October 2023, were included. Biological specimens from a subset of 60 patients were prospectively collected for biobanking at baseline, immediately post-procedure and after 12 months. RESULTS: Two hundred fifty-nine (44%) patients were under 1 year old at their first procedure. The median KAP/weight was 0.09 Gy·cm2/kg (IQR: 0.03-0.20), and the median fluoroscopy time was 8.10 min (IQR: 4.00-16.25). KAP/weight ratio showed a positive correlation with the fluoroscopy time (Spearman's rho = 0.679, p < 0.001). Significant dose reduction was observed either after implementation of an upgraded technology system and a radiation training among staff. The Italian cohort includes 1858 different types of specimens for Harmonic biobank, including blood, plasma, serum, clot, cell pellet/lymphocytes, saliva. CONCLUSIONS: In the Italian Harmonic cohort, radiation dose in cardiac catheterization varies by age and procedure type. An institution's radiological protection strategy has contributed to a reduction in radiation dose over time. Biological samples provide a valuable resource for future research, offering an opportunity to identify potential early biomarkers for health surveillance and personalized risk assessment.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Radiation Exposure , Humans , Italy , Male , Child , Female , Child, Preschool , Adolescent , Retrospective Studies , Radiation Exposure/adverse effects , Fluoroscopy/adverse effects , Radiation Dosage , Cohort Studies
14.
J Am Heart Assoc ; 13(10): e034552, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38726901

ABSTRACT

BACKGROUND: Fractional flow reserve (FFR) is the ratio of blood pressure measured distal to a stenosis and pressure proximal to a stenosis. FFR can be estimated noninvasively using computed tomography (CT) although the usefulness of this technique remains controversial. This meta-analysis evaluated the agreement of FFR estimated by CT (FFR-CT) with invasively measured FFR. The study also evaluated the diagnostic accuracy of FFR-CT, defined as the ability of FFR-CT to classify lesions as hemodynamically significant (invasive FFR ≤0.8) or insignificant (invasive FFR >0.8). METHODS AND RESULTS: Forty-three studies reporting on 7291 blood vessels from 5236 patients were included. A moderate positive linear relationship between FFR-CT and invasively measured FFR was observed (Spearman correlation coefficient: 0.67). Agreement between the 2 measures increased as invasively measured FFR values approached 1. The overall diagnostic accuracy, sensitivity and specificity of FFR-CT were 82.2%, 80.9%, and 83.1%, respectively. Diagnostic accuracy of 90% could be demonstrated for FFR-CT values >0.90 and <0.49. The diagnostic accuracy of off-site tools was 79.4% and the diagnostic accuracy of on-site tools was 84.1%. CONCLUSIONS: The agreement between FFR-CT and invasive FFR is moderate although agreement is highest in vessels with FFR-CT >0.9. Diagnostic accuracy varies widely with FFR-CT value but is above 90% for FFR-CT values >0.90 and <0.49. Furthermore, on-site and off-site tools have similar performance. Ultimately, FFR-CT may be a useful adjunct to CT coronary angiography as a gatekeeper for invasive coronary angiogram.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Fractional Flow Reserve, Myocardial/physiology , Humans , Coronary Stenosis/physiopathology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/diagnosis , Coronary Angiography/methods , Computed Tomography Angiography/methods , Predictive Value of Tests , Cardiac Catheterization , Reproducibility of Results , Coronary Artery Disease/physiopathology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/diagnosis , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Severity of Illness Index , Tomography, X-Ray Computed/methods
16.
Sci Rep ; 14(1): 11504, 2024 05 20.
Article in English | MEDLINE | ID: mdl-38769360

ABSTRACT

Pressure drifting is a troublesome error in invasive coronary function tests. This study aimed to evaluate the relationship between prolonged and short-time pressure equalizations in pressure drifting. Pressure drifting was defined as the pressure gradient between the mean pressure of the distal wire sensor (Pd) and aortic pressure (Pa) when the wire was withdrawn to the tip of the guiding catheter. Significant drifts 1 and 2 were defined as the absolute values of pressure gradients > 2 and > 3 mmHg, respectively. A logistic regression model was used to evaluate the associations between prolonged pressure equalization and each pressure drifting. The prolonged pressure equalization strategy was associated with a lower incidence of drift 1 than the short-time pressure equalization strategy (6.84% vs. 16.92%, p < 0.05). However, no statistical differences were found in the incidence of drift 2 between the prolonged and short-time pressure equalization strategies (4.27% vs. 7.69%, p = 0.34). In the multivariable regression model, only the prolonged pressure equalization strategy predicted a lower incidence of pressure drift 1. In conclusion, the prolonged pressure equalization strategy was associated with a lower incidence of significant pressure drifting with more stringent thresholds than the short-time pressure equalization strategy.


Subject(s)
Cardiac Catheterization , Humans , Male , Female , Aged , Middle Aged , Cardiac Catheterization/methods , Pressure , Blood Pressure/physiology
17.
EuroIntervention ; 20(9): 561-570, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726719

ABSTRACT

BACKGROUND: Vessel-level physiological data derived from pressure wire measurements are one of the important determinant factors in the optimal revascularisation strategy for patients with multivessel disease (MVD). However, these may result in complications and a prolonged procedure time. AIMS: The feasibility of using the quantitative flow ratio (QFR), an angiography-derived fractional flow reserve (FFR), in Heart Team discussions to determine the optimal revascularisation strategy for patients with MVD was investigated. METHODS: Two Heart Teams were randomly assigned either QFR- or FFR-based data of the included patients. They then discussed the optimal revascularisation mode (percutaneous coronary intervention [PCI] or coronary artery bypass grafting [CABG]) for each patient and made treatment recommendations. The primary endpoint of the trial was the level of agreement between the treatment recommendations of both teams as assessed using Cohen's kappa. RESULTS: The trial included 248 patients with MVD from 10 study sites. Cohen's kappa in the recommended revascularisation modes between the QFR and FFR approaches was 0.73 [95% confidence interval {CI} : 0.62-0.83]. As for the revascularisation planning, agreements in the target vessels for PCI and CABG were substantial for both revascularisation modes (Cohen's kappa=0.72 [95% CI: 0.66-0.78] and 0.72 [95% CI: 0.66-0.78], respectively). The team assigned to the QFR approach provided consistent recommended revascularisation modes even after being made aware of the FFR data (Cohen's kappa=0.95 [95% CI:0.90-1.00]). CONCLUSIONS: QFR provided feasible physiological data in Heart Team discussions to determine the optimal revascularisation strategy for MVD. The QFR and FFR approaches agreed substantially in terms of treatment recommendations.


Subject(s)
Coronary Angiography , Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Humans , Fractional Flow Reserve, Myocardial/physiology , Female , Male , Coronary Artery Disease/physiopathology , Coronary Artery Disease/therapy , Coronary Artery Disease/surgery , Coronary Artery Disease/diagnostic imaging , Middle Aged , Percutaneous Coronary Intervention/methods , Aged , Coronary Artery Bypass/methods , Clinical Decision-Making , Cardiac Catheterization/methods , Patient Care Team
19.
Int Heart J ; 65(3): 566-571, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38749750

ABSTRACT

Cardiopulmonary resuscitation (CPR) is essential for the survival of cardiac arrest patients, but it can cause severe traumatic complications. In the catheterization laboratory, various physical constraints complicate the appropriate performance of CPR. However, we are not aware of reports of CPR complications in this setting. Here, we report a case of coronary artery perforation (CAP) caused by manual CPR in the catheterization laboratory. The patient, a 68-year-old woman, initially underwent successful percutaneous coronary intervention (PCI) for unstable angina. Back in the ward, the patient experienced acute stent thrombosis, which resulted in cardiac arrest, and another PCI was performed under ongoing manual CPR. Although revascularization was successful, sudden CAP occurred, leading to cardiac tamponade. Despite extensive treatment efforts, the patient died 18 hours later.Initially, the compression site of CPR was on the midline of the sternum; however, the compression site shifted to the left, to just above the left anterior descending artery, by the time that CAP was detected via angiography. This corresponded to the area where rib fractures were observed upon computed tomography, suggesting the possibility of traumatic CAP due to manual CPR. The physical constraints in the catheterization laboratory can lead to an inappropriate CPR technique and severe traumatic complications.


Subject(s)
Cardiopulmonary Resuscitation , Coronary Vessels , Percutaneous Coronary Intervention , Humans , Aged , Female , Cardiopulmonary Resuscitation/adverse effects , Cardiopulmonary Resuscitation/methods , Coronary Vessels/injuries , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention/adverse effects , Fatal Outcome , Heart Arrest/etiology , Heart Arrest/therapy , Coronary Angiography , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Angina, Unstable/therapy , Angina, Unstable/etiology , Cardiac Tamponade/etiology
20.
J Am Coll Cardiol ; 83(18): 1799-1817, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38692830

ABSTRACT

Severe acute mitral regurgitation after myocardial infarction includes partial and complete papillary muscle rupture or functional mitral regurgitation. Although its incidence is <1%, mitral regurgitation after acute myocardial infarction frequently causes hemodynamic instability, pulmonary edema, and cardiogenic shock. Medical management has the worst prognosis, and mortality has not changed in decades. Surgery represents the gold standard, but it is associated with high rates of morbidity and mortality. Recently, transcatheter interventions have opened a new door for management that may improve survival. Mechanical circulatory support restores vital organ perfusion and offers the opportunity for a steadier surgical repair. This review focuses on the diagnosis and the interventional management, both surgical and transcatheter, with a glance on future perspectives to enhance patient management and eventually decrease mortality.


Subject(s)
Mitral Valve Insufficiency , Myocardial Infarction , Humans , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/therapy , Myocardial Infarction/complications , Myocardial Infarction/therapy , Severity of Illness Index , Cardiac Catheterization/methods , Disease Management
SELECTION OF CITATIONS
SEARCH DETAIL
...