Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.964
Filter
1.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38749587

ABSTRACT

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Subject(s)
Balloon Valvuloplasty , Cardiac Catheterization , Heart Valve Prosthesis Implantation , Palliative Care , Stents , Tetralogy of Fallot , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/physiopathology , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Infant , Treatment Outcome , Age Factors , Child, Preschool , Child , Adult , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Infant, Newborn , Young Adult , Cardiac Surgical Procedures/adverse effects , Risk Factors , Female , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Male , Hemodynamics , Middle Aged , Recovery of Function
2.
PLoS One ; 19(5): e0301939, 2024.
Article in English | MEDLINE | ID: mdl-38781278

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has garnered interest as a viable alternative to the traditional surgical mitral valve replacement (SMVR) for high-risk patients requiring redo operations. This study aims to evaluate the association of TMVR with selected clinical and financial outcomes. METHODS: Adults undergoing isolated redo mitral valve replacement were identified in the 2016-2020 Nationwide Readmissions Database and categorized into TMVR or SMVR cohorts. Various regression models were developed to assess the association between TMVR and in-hospital mortality, as well as additional secondary outcomes. Transseptal and transapical catheter-based approaches were also compared in relation to study endpoints. RESULTS: Of an estimated 7,725 patients, 2,941 (38.1%) underwent TMVR. During the study period, the proportion of TMVR for redo operations increased from 17.8% to 46.7% (nptrend<0.001). Following adjustment, TMVR was associated with similar odds of in-hospital mortality (AOR 0.82, p = 0.48), but lower odds of stroke (AOR 0.44, p = 0.001), prolonged ventilation (AOR 0.43, p<0.001), acute kidney injury (AOR 0.61, p<0.001), and reoperation (AOR 0.29, p = 0.02). TMVR was additionally correlated with shorter postoperative length of stay (pLOS; ß -0.98, p<0.001) and reduced costs (ß -$10,100, p = 0.002). Additional analysis demonstrated that the transseptal approach had lower adjusted mortality (AOR 0.44, p = 0.02), shorter adjusted pLOS (ß -0.43, p<0.001), but higher overall costs (ß $5,200, p = 0.04), compared to transapical. CONCLUSIONS: In this retrospective cohort study, we noted TMVR to yield similar odds of in-hospital mortality as SMVR, but fewer complications and reduced healthcare expenditures. Moreover, transseptal approaches were associated with lower adjusted mortality, shorter pLOS, but higher cost, relative to the transapical. Our findings suggest that TMVR represent a cost-effective and safe treatment modality for patients requiring redo mitral valve procedures. Nevertheless, future studies examining long-term outcomes associated with SMVR and TMVR in redo mitral valve operations, are needed.


Subject(s)
Heart Valve Prosthesis Implantation , Hospital Mortality , Mitral Valve , Humans , Male , Female , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/economics , Heart Valve Prosthesis Implantation/adverse effects , Aged , Mitral Valve/surgery , Middle Aged , Reoperation/statistics & numerical data , Cardiac Catheterization/methods , Cardiac Catheterization/economics , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Retrospective Studies , Length of Stay , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Postoperative Complications/etiology , Aged, 80 and over , United States/epidemiology
3.
Int Heart J ; 65(3): 566-571, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38749750

ABSTRACT

Cardiopulmonary resuscitation (CPR) is essential for the survival of cardiac arrest patients, but it can cause severe traumatic complications. In the catheterization laboratory, various physical constraints complicate the appropriate performance of CPR. However, we are not aware of reports of CPR complications in this setting. Here, we report a case of coronary artery perforation (CAP) caused by manual CPR in the catheterization laboratory. The patient, a 68-year-old woman, initially underwent successful percutaneous coronary intervention (PCI) for unstable angina. Back in the ward, the patient experienced acute stent thrombosis, which resulted in cardiac arrest, and another PCI was performed under ongoing manual CPR. Although revascularization was successful, sudden CAP occurred, leading to cardiac tamponade. Despite extensive treatment efforts, the patient died 18 hours later.Initially, the compression site of CPR was on the midline of the sternum; however, the compression site shifted to the left, to just above the left anterior descending artery, by the time that CAP was detected via angiography. This corresponded to the area where rib fractures were observed upon computed tomography, suggesting the possibility of traumatic CAP due to manual CPR. The physical constraints in the catheterization laboratory can lead to an inappropriate CPR technique and severe traumatic complications.


Subject(s)
Cardiopulmonary Resuscitation , Coronary Vessels , Percutaneous Coronary Intervention , Humans , Aged , Female , Cardiopulmonary Resuscitation/adverse effects , Cardiopulmonary Resuscitation/methods , Coronary Vessels/injuries , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention/adverse effects , Fatal Outcome , Heart Arrest/etiology , Heart Arrest/therapy , Coronary Angiography , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Angina, Unstable/therapy , Angina, Unstable/etiology , Cardiac Tamponade/etiology
4.
Sci Rep ; 14(1): 11937, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789491

ABSTRACT

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Retrospective Studies , Echocardiography, Transesophageal/methods , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Aged, 80 and over , Echocardiography, Three-Dimensional/methods , Middle Aged , Echocardiography/methods , Treatment Outcome , Cardiac Catheters , Left Atrial Appendage Closure
5.
Clin Cardiol ; 47(5): e24272, 2024 May.
Article in English | MEDLINE | ID: mdl-38742736

ABSTRACT

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Prosthesis Failure , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Echocardiography, Transesophageal , Male , Treatment Outcome , Female , Aged , Reoperation
6.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38695165

ABSTRACT

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Subject(s)
Cardiac Catheterization , Cardiac Catheters , Mitral Valve Insufficiency , Mitral Valve , Punctures , Humans , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Treatment Outcome , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Equipment Design , Heart Septum/surgery , Heart Septum/diagnostic imaging , Heart Valve Prosthesis
9.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599692

ABSTRACT

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Follow-Up Studies , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
12.
BMC Cardiovasc Disord ; 24(1): 198, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580946

ABSTRACT

BACKGROUND: Migraine is a leading cause of disability worldwide. Several retrospective studies have suggested that the closure of the Patent Foramen Ovale (PFO) may provide relief from migraines. However, three randomized controlled trials did not meet their primary endpoints regarding migraine cessation, reduction in monthly migraine days, and responder rates. METHODS: The SPRING study is a multicenter, prospective, randomized, and open-label trial designed to compare the effectiveness and safety of PFO closure versus medication in the relief of migraines. The primary endpoint is the total cessation of migraines, as recorded in patient headache diaries during the follow-up period. Additional diagnostic tools include echocardiography with agitated saline contrast, transcranial Doppler, and routine laboratory measurements. CONCLUSION: The SPRING trial aims to assess the effectiveness and safety of PFO closure versus medication in mitigating migraines in real-world settings. (Clinical Trails ID: NCT04946734).


Subject(s)
Foramen Ovale, Patent , Migraine Disorders , Humans , Retrospective Studies , Prospective Studies , Treatment Outcome , Migraine Disorders/diagnosis , Migraine Disorders/prevention & control , Migraine Disorders/etiology , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/therapy , Foramen Ovale, Patent/complications , Cardiac Catheterization/adverse effects , Randomized Controlled Trials as Topic
13.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Article in English | MEDLINE | ID: mdl-38584522

ABSTRACT

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Subject(s)
Cardiac Catheterization , Ductus Arteriosus, Patent , Ultrasonography, Interventional , Humans , Ductus Arteriosus, Patent/therapy , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/physiopathology , Infant, Newborn , Retrospective Studies , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Treatment Outcome , Gestational Age , Predictive Value of Tests , Male , Female , Time Factors , Severity of Illness Index , Infant, Premature , Infant, Extremely Premature , Intensive Care Units, Neonatal , Point-of-Care Systems , Point-of-Care Testing , Septal Occluder Device , Infant
14.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Article in English | MEDLINE | ID: mdl-38597297

ABSTRACT

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Subject(s)
Cardiac Catheterization , Finite Element Analysis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Models, Cardiovascular , Patient-Specific Modeling , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/physiopathology , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Risk Assessment , Adolescent , Treatment Outcome , Risk Factors , Male , Child , Retrospective Studies , Female , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Young Adult , Predictive Value of Tests , Hemodynamics , Stents , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Ventricular Outflow Obstruction/physiopathology , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/diagnostic imaging , Clinical Decision-Making , Adult
15.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Article in English | MEDLINE | ID: mdl-38639143

ABSTRACT

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Subject(s)
Ablation Techniques , Cardiac Catheterization , Cardiomyopathy, Hypertrophic , Ethanol , Heart Valve Prosthesis Implantation , Mitral Valve , Humans , Retrospective Studies , Male , Ethanol/administration & dosage , Ethanol/adverse effects , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/therapy , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/physiopathology , Female , Treatment Outcome , Ablation Techniques/adverse effects , Ablation Techniques/mortality , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Cardiac Catheterization/instrumentation , Middle Aged , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Time Factors , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve/surgery , Recovery of Function , Aged, 80 and over , Heart Septum/diagnostic imaging , Heart Septum/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality
16.
J Am Heart Assoc ; 13(8): e033510, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38567665

ABSTRACT

BACKGROUND: Pulmonary hypertension (PH) and secondary mitral regurgitation (MR) are associated with adverse outcomes after mitral transcatheter edge-to-edge repair. We aim to study the prognostic value of invasively measured right ventricular afterload in patients undergoing mitral transcatheter edge-to-edge repair. METHODS AND RESULTS: We identified patients who underwent right heart catheterization ≤1 month before transcatheter edge-to-edge repair. The end points were all-cause mortality and a composite of mortality and heart failure hospitalization at 2 years. Using the receiver operating characteristic curve-derived threshold of 0.6 for pulmonary effective arterial elastance ([Ea], pulmonary artery systolic pressure/stroke volume), patients were stratified into 3 profiles based on PH severity (low elastance [HE]: Ea <0.6/mean pulmonary artery pressure (mPAP)) <35; High Elastance with No/Mild PH (HE-): Ea ≥0.6/mPAP <35; and HE with Moderate/Severe PH (HE+): Ea ≥0.6/mPAP ≥35) and MR pathogenesis (Primary MR [PMR])/low elastance, PMR/HE, and secondary MR). The association between this classification and clinical outcomes was examined using Cox regression. Among 114 patients included, 50.9% had PMR. Mean±SD age was 74.7±10.6 years. Patients with Ea ≥0.6 were more likely to have diabetes, atrial fibrillation, New York Heart Association III/IV status, and secondary MR (all P<0.05). Overall, 2-year cumulative survival was 71.1% and was lower in patients with secondary MR and mPAP ≥35. Compared with patients with low elastance, cumulative 2-year event-free survival was significantly lower in HE- and HE+ patients (85.5% versus 50.4% versus 41.0%, respectively, P=0.001). Also, cumulative 2-year event-free survival was significantly higher in patients with PMR/low elastance when compared with PMR/HE and patients with secondary mitral regurgitation (85.5% versus 55.5% versus 46.1%, respectively, P=0.005). CONCLUSIONS: Assessment of the preprocedural cardiopulmonary profile based on mPAP, MR pathogenesis, and Ea guides patient selection by identifying hemodynamic features that indicate likely benefit from mitral-transcatheter edge-to-edge repair in PH or lack thereof.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Middle Aged , Aged , Aged, 80 and over , Prognosis , Mitral Valve Insufficiency/surgery , Hemodynamics , Cardiac Catheterization/adverse effects , Pulmonary Artery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
17.
Cell Mol Biol (Noisy-le-grand) ; 70(4): 225-230, 2024 Apr 28.
Article in English | MEDLINE | ID: mdl-38678600

ABSTRACT

This study compared the therapeutic effect and safety between warfarin anticoagulation and percutaneous left atrial appendage transcatheter occlusion (PLAATO) in non-valvular atrial fibrillation (NVAF). A total of 110 patients were selected and assigned to Control group (n=55) and Observation group (n=55). The control patients were used warfarin, while the observation patients were performed PLAATO. The coagulation function, stroke and bleeding scores were compared between the two groups at different times. Left ventricular function before therapy and 1 year after therapy and adverse events during follow-up were compared between the two groups. After one month of treatment, CHA2DS2-VASC, HAS-BLED score, serum ET-1 and hs-CRP levels were lower in the PLAATO patients than in warfarin patients, but serum PDGFs levels were higher than patients in the warfarin patients (P < 0.05). One month after treatment, the activated partial thromboplastin time (APTT), prothrombin time (PT), and thrombin time (TT) of the PLAATO patients was longer than that of the warfarin patients (P < 0.05), but the levels of fibrinogen (FIB) in the PLAATO patients were lower than that of the warfarin patients (P < 0.05). In addition, one year after therapy, the left atrial end-diastolic volume (LAEDV), left atrial end-systolic volume (LAESV) and left atrial inner diameter of the two groups were significantly reduced (P < 0.05). Left atrial appendage (LAA) occlusion can effectively improve the cardiac function and coagulation function of NVAF patients, with lower incidence of bleeding events, stroke events and higher safety.


Subject(s)
Anticoagulants , Atrial Appendage , Atrial Fibrillation , Warfarin , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/therapy , Warfarin/therapeutic use , Warfarin/adverse effects , Male , Atrial Appendage/surgery , Female , Anticoagulants/therapeutic use , Anticoagulants/adverse effects , Aged , C-Reactive Protein/metabolism , Middle Aged , Treatment Outcome , Stroke/etiology , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects
18.
Nutr Metab Cardiovasc Dis ; 34(6): 1538-1545, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38644080

ABSTRACT

BACKGROUND AND AIMS: The role of fractional flow reserve (FFR) in coronary intermediate lesions is widely recommended by guidelines. The effect of uric acid (UA) on cardiovascular events is also well known. However, the relationship between UA and long-term cardiovascular outcomes in patients who received FFR with intermediate lesions remains unknown. METHODS AND RESULTS: We retrospectively included 428 patients who underwent both coronary angiography (CAG) and FFR. Participants were stratified into two groups based on the median UA. The primary endpoint was the composite of major adverse cardiovascular and cerebrovascular events (MACCEs), including repeat revascularization, nonfatal stroke, nonfatal myocardial infarction, and all-cause death. A Cox proportional hazards model was utilized to analyze the association between UA and the prevalence of MACCEs. During a median follow-up of 5.8 years, a higher MACCEs rate occurred in the high UA group compared to the low UA group (16.8% vs. 5.1%, p log-rank<0.01). Elevated UA was independently linked to a higher incidence of MACCEs, whether UA was treated as a categorical or continuous variable (hazard ratio [HR] 2.76, 95% confidence interval [CI] 1.27-6.03 or HR 1.01, 95% CI 1.01-1.02). The restricted cubic spline (RCS) analysis illustrated that the HR for MACCEs increased with increasing UA. CONCLUSION: The present study demonstrates that UA is associated with MACCEs risk and suggests that UA is a reliable predictor of long-term cardiovascular events in coronary intermediate stenosis patients.


Subject(s)
Biomarkers , Coronary Angiography , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Hyperuricemia , Uric Acid , Humans , Male , Female , Uric Acid/blood , Retrospective Studies , Aged , Middle Aged , Time Factors , Risk Factors , Coronary Stenosis/physiopathology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/diagnosis , Coronary Stenosis/blood , Risk Assessment , Hyperuricemia/diagnosis , Hyperuricemia/blood , Hyperuricemia/epidemiology , Hyperuricemia/physiopathology , Biomarkers/blood , Up-Regulation , Coronary Artery Disease/physiopathology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/diagnosis , Coronary Artery Disease/blood , Predictive Value of Tests , Cardiac Catheterization/adverse effects
20.
Catheter Cardiovasc Interv ; 103(7): 1152-1155, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38606476

ABSTRACT

The use of left atrial appendage occlusion (LAAO) devices have gained prominence as an alternative to long-term anticoagulation therapy in patients with atrial fibrillation at risk of stroke and high risk of bleeding. While these devices have shown efficacy in reducing stroke risk, there have been reported cases of embolization of the Watchman device. There are very few cases of successful percutaneous retrieval of embolized Watchman devices from the left ventricle (LV), as many of these cases require open heart surgery for safe removal. We are presenting a case of an 80-year-old male whose Watchman device embolized to the LV and was entrapped on the LV papillary muscle that was then successfully retrieved via percutaneous methods, which shows the percutaneous options remain a viable strategy to retrieve LAAO devices from the LV.


Subject(s)
Atrial Fibrillation , Cardiac Catheterization , Device Removal , Foreign-Body Migration , Papillary Muscles , Humans , Male , Aged, 80 and over , Treatment Outcome , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Foreign-Body Migration/therapy , Foreign-Body Migration/etiology , Foreign-Body Migration/diagnostic imaging , Papillary Muscles/diagnostic imaging , Heart Ventricles/diagnostic imaging , Embolism/etiology , Embolism/diagnostic imaging , Embolism/therapy , Embolism/diagnosis , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Echocardiography, Transesophageal
SELECTION OF CITATIONS
SEARCH DETAIL
...