Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.053
Filter
1.
Clin Cardiol ; 47(5): e24272, 2024 May.
Article in English | MEDLINE | ID: mdl-38742736

ABSTRACT

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Prosthesis Failure , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Echocardiography, Transesophageal , Male , Treatment Outcome , Female , Aged , Reoperation
3.
Article in English | MEDLINE | ID: mdl-38727533

ABSTRACT

Preoperative calculations showed that the 9-mm inlet, 6-mm outlet, 25-cc pump chambers and 65-73 bpm would be optimal for a 5-year-old patient suffering from restrictive cardiomyopathy, with a body surface area of 0.59 m2 (1.5 L/min flow for a cardiac index of 2.5). After re-sternotomy and standard bicaval cannulation for cardiopulmonary bypass, the procedure was performed under normothermic conditions and on the beating heart. Biventricular support was established with the Berlin Heart Excor using biatrial cannulation. For left atrial cannulation, induced ventricular fibrillation was used. The 9-mm inlet cannulas were inserted into the left and right atria, respectively. The 6-mm outlet cannulas were implanted using 8-mm interposition vascular grafts for the aorta and the main pulmonary artery, respectively. Cannulas were tunnelled through the epigastric space, with systems crossing outside of the body. The 25-cc chambers were used for both right ventricular assist device and left ventricular assist device support, which subsequently showed full emptying and filling.


Subject(s)
Cardiomyopathy, Restrictive , Heart-Assist Devices , Humans , Cardiomyopathy, Restrictive/surgery , Cardiomyopathy, Restrictive/diagnosis , Male , Child, Preschool , Heart Atria/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/instrumentation , Heart Failure/surgery , Prosthesis Implantation/methods
5.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38749587

ABSTRACT

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Subject(s)
Balloon Valvuloplasty , Cardiac Catheterization , Heart Valve Prosthesis Implantation , Palliative Care , Stents , Tetralogy of Fallot , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/physiopathology , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Infant , Treatment Outcome , Age Factors , Child, Preschool , Child , Adult , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Infant, Newborn , Young Adult , Cardiac Surgical Procedures/adverse effects , Risk Factors , Female , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Male , Hemodynamics , Middle Aged , Recovery of Function
6.
Sci Rep ; 14(1): 11937, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789491

ABSTRACT

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Retrospective Studies , Echocardiography, Transesophageal/methods , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Aged, 80 and over , Echocardiography, Three-Dimensional/methods , Middle Aged , Echocardiography/methods , Treatment Outcome , Cardiac Catheters , Left Atrial Appendage Closure
7.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38742523

ABSTRACT

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Italy/epidemiology , Aged, 80 and over , Patient Readmission/statistics & numerical data , Treatment Failure , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Annuloplasty/adverse effects , Treatment Outcome , Time Factors , Risk Factors , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/surgery
8.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38695165

ABSTRACT

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Subject(s)
Cardiac Catheterization , Cardiac Catheters , Mitral Valve Insufficiency , Mitral Valve , Punctures , Humans , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Equipment Design , Heart Septum/surgery , Heart Septum/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Article in English | MEDLINE | ID: mdl-38662126

ABSTRACT

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Predictive Value of Tests , Prosthesis Design , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Female , Male , Aged , Aged, 80 and over , Risk Factors , Treatment Outcome , Time Factors , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Retrospective Studies , Incidence , Tomography, X-Ray Computed , Multidetector Computed Tomography
11.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Article in English | MEDLINE | ID: mdl-38584522

ABSTRACT

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Subject(s)
Cardiac Catheterization , Ductus Arteriosus, Patent , Ultrasonography, Interventional , Humans , Ductus Arteriosus, Patent/therapy , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/physiopathology , Infant, Newborn , Retrospective Studies , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Treatment Outcome , Gestational Age , Predictive Value of Tests , Male , Female , Time Factors , Severity of Illness Index , Infant, Premature , Infant, Extremely Premature , Intensive Care Units, Neonatal , Point-of-Care Systems , Point-of-Care Testing , Septal Occluder Device , Infant
12.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Article in English | MEDLINE | ID: mdl-38597297

ABSTRACT

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Subject(s)
Cardiac Catheterization , Finite Element Analysis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Models, Cardiovascular , Patient-Specific Modeling , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/physiopathology , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Risk Assessment , Adolescent , Treatment Outcome , Risk Factors , Male , Child , Retrospective Studies , Female , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Young Adult , Predictive Value of Tests , Hemodynamics , Stents , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Ventricular Outflow Obstruction/physiopathology , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/diagnostic imaging , Clinical Decision-Making , Adult
13.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Article in English | MEDLINE | ID: mdl-38639143

ABSTRACT

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Subject(s)
Ablation Techniques , Cardiac Catheterization , Cardiomyopathy, Hypertrophic , Ethanol , Heart Valve Prosthesis Implantation , Mitral Valve , Humans , Retrospective Studies , Male , Ethanol/administration & dosage , Ethanol/adverse effects , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/therapy , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/physiopathology , Female , Treatment Outcome , Ablation Techniques/adverse effects , Ablation Techniques/mortality , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Cardiac Catheterization/instrumentation , Middle Aged , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Time Factors , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve/surgery , Recovery of Function , Aged, 80 and over , Heart Septum/diagnostic imaging , Heart Septum/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality
15.
Catheter Cardiovasc Interv ; 103(7): 1159-1164, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38639138

ABSTRACT

Despite progressively uncommon in Western countries, rheumatic heart disease still portrays a significant global burden. In elderly or high-surgical risk patients, plurivalvular disease may require a complex percutaneous approach. Transcatheter aortic valve implantation (TAVI) in patients with previous monoleaflet mitral prosthesis is challenging due to interference between the aortic valve and the rigid mitral mechanical prosthesis "ring." Prior cases report the use of CoreValve or Edwards Sapien aortic valves in patients with adequate mitro-aortic distance. Performing a second major procedure, such as tricuspid valve-in-valve (TVIV), sequentially during a single percutaneous intervention, increases treatment complexity. An 83-year-old woman with rheumatic heart disease, with previous implantation of a Bjork-Shiley monoleaflet mitral prosthesis, and Carpentier-Edwards 29 tricuspid bioprosthesis presented with decompensated heart failure due to severe aortic stenosis and tricuspid bioprosthesis stenosis. After HeartTeam discussion, the patient was deemed as inoperable due to a prohibitive surgical risk. As an alternative, a TAVI (Navitor FlexNav) and a transcatheter TVIV replacement (Edwards Sapiens 3 Ultra) were discussed and proposed, with both techniques being performed sequentially in a single procedure. TAVI in a patient with a previous monoleaflet mitral mechanical prosthesis and TVIV may be a feasible approach in inoperable patients with plurivalvular disease.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Prosthesis Design , Rheumatic Heart Disease , Transcatheter Aortic Valve Replacement , Tricuspid Valve , Humans , Female , Aged, 80 and over , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve/physiopathology , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/physiopathology , Rheumatic Heart Disease/surgery , Rheumatic Heart Disease/therapy , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Cardiac Catheterization/instrumentation , Recovery of Function , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnostic imaging
16.
Catheter Cardiovasc Interv ; 103(7): 1148-1151, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38639161

ABSTRACT

The transcatheter edge-to-edge mitral valve repair (TEER) has been recommended as a reliable treatment option for selected patients with severe degenerative and functional mitral regurgitation (MR). Although MR patients with rheumatic etiology were excluded from two significant trials (EVEREST II and COAPT) that established a role for the TEER in degenerative and functional MR. However, it has been reported that the TEER procedure could be safely and effectively performed in carefully selected rheumatic MR patients. Therefore, we share a case report of successfully treating severe rheumatic MR using a novel-designed TEER system (JensClipTM).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Rheumatic Heart Disease , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/etiology , Cardiac Catheterization/instrumentation , Treatment Outcome , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/surgery , Rheumatic Heart Disease/physiopathology , Rheumatic Heart Disease/therapy , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Female , Echocardiography, Transesophageal , Echocardiography, Doppler, Color , Prosthesis Design , Heart Valve Prosthesis , Middle Aged , Male
18.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Article in English | MEDLINE | ID: mdl-38606564

ABSTRACT

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Treatment Outcome , Male , Female , Adolescent , Young Adult , Child , Adult , Retrospective Studies , Predictive Value of Tests , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Patient Selection , Clinical Decision-Making , Recovery of Function , Hemodynamics
19.
Circ Cardiovasc Interv ; 17(5): e013579, 2024 May.
Article in English | MEDLINE | ID: mdl-38629273

ABSTRACT

BACKGROUND: The prognostic impact of left atrial appendage (LAA) patency, including those with and without visible peri-device leak (PDL), post-LAA closure in patients with atrial fibrillation, remains elusive. METHODS: Patients with atrial fibrillation implanted with the WATCHMAN 2.5 device were prospectively enrolled. The device surveillance by cardiac computed tomography angiography was performed at 3 months post-procedure. Adverse events, including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular death, all-cause death, and the combined major adverse events (MAEs), were compared between patients with complete closure and LAA patency. RESULTS: Among 519 patients with cardiac computed tomography angiography surveillance at 3 months post-LAA closure, 271 (52.2%) showed complete closure, and LAA patency was detected in 248 (47.8%) patients, including 196 (37.8%) with visible PDL and 52 (10.0%) without visible PDL. During a median of 1193 (787-1543) days follow-up, the presence of LAA patency was associated with increased risks of stroke/TIA (adjusted hazard ratio for baseline differences, 3.22 [95% CI, 1.17-8.83]; P=0.023) and MAEs (adjusted hazard ratio, 1.12 [95% CI, 1.06-1.17]; P=0.003). Specifically, LAA patency with visible PDL was associated with increased risks of stroke/TIA (hazard ratio, 3.66 [95% CI, 1.29-10.42]; P=0.015) and MAEs (hazard ratio, 3.71 [95% CI, 1.71-8.07]; P=0.001), although LAA patency without visible PDL showed higher risks of MAEs (hazard ratio, 3.59 [95% CI, 1.28-10.09]; P=0.015). Incidences of stroke/TIA (2.8% versus 3.0% versus 6.7% versus 22.2%; P=0.010), cardiovascular death (0.9% versus 0% versus 1.7% versus 11.1%; P=0.005), and MAEs (4.6% versus 9.0% versus 11.7% versus 22.2%; P=0.017) increased with larger PDL (0, >0 to ≤3, >3 to ≤5, or >5 mm). Older age and discontinuing antiplatelet therapy at 6 months were independent predictors of stroke/TIA and MAEs in patients with LAA patency. CONCLUSIONS: LAA patency detected by cardiac computed tomography angiography at 3 months post-LAA closure is associated with unfavorable prognosis in patients with atrial fibrillation implanted with WATCHMAN 2.5 device. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03788941.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Computed Tomography Angiography , Ischemic Attack, Transient , Stroke , Humans , Atrial Appendage/physiopathology , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/mortality , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnostic imaging , Prospective Studies , Risk Factors , Ischemic Attack, Transient/etiology , Time Factors , Treatment Outcome , Stroke/etiology , Stroke/mortality , Aged, 80 and over , Middle Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Risk Assessment , Hemorrhage , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...