Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 6.459
Filter
1.
BMC Anesthesiol ; 24(1): 201, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38844869

ABSTRACT

BACKGROUND: Significant hemodynamic changes occur during liver transplantation, emphasizing the importance of precious and continuous monitoring of cardiac output, cardiac index, and other parameters. Although the monitoring of cardiac output by pulse indicator continuous cardiac output (PiCCO) was statistically homogeneous compared to the clinical gold standard pulmonary artery catheterization (PAC) in previous studies of liver transplantation, there are fewer statistical methods for the assessment of its conclusions, and a lack of comparisons of other hemodynamic parameters (e.g., SVRI, systemic vascular resistance index). Some studies have also concluded that the agreement between PiCCO and PAC is not good enough. Overall, there are no uniform conclusions regarding the agreement between PiCCO and PAC in previous studies. This study evaluates the agreement and trending ability of relevant hemodynamic parameters obtained with PiCCO compared to the clinical gold standard PAC from multiple perspectives, employing various statistical methods. METHODS: Fifty-two liver transplantation patients were included. Cardiac output (CO), cardiac index (CI), SVRI and stroke volume index (SVI) values were monitored at eight time points using both PiCCO and PAC. The results were analyzed by Bland-Altman analysis, Passing-bablok regression, intra-class correlation coefficient (ICC), 4-quadrant plot, polar plot, and trend interchangeability method (TIM). RESULTS: The Bland-Altman analysis revealed high percentage errors for PiCCO: 54.06% for CO, 52.70% for CI, 62.18% for SVRI, and 51.97% for SVI, indicating poor accuracy. While Passing-Bablok plots showed favorable agreement for SVRI overall and during various phases, the agreement for other parameters was less satisfactory. The ICC results confirmed good overall agreement between the two devices across most parameters, except for SVRI during the new liver phase, which showed poor agreement. Additionally, four-quadrant and polar plot analyses indicated that all agreement rate values fell below the clinically acceptable threshold of over 90%, and all angular deviation values exceeded ± 5°, demonstrating that PiCCO is unable to meet the acceptable trends. Using the TIM, the interchangeability rates were found to be quite low: 20% for CO and CI, 16% for SVRI, and 13% for SVI. CONCLUSIONS: Our study revealed notable disparities in absolute values of CO, CI, SVRI and SVI between PiCCO and PAC in intraoperative liver transplant settings, notably during the neohepatic phase where errors were particularly pronounced. Consequently, these findings highlight the need for careful consideration of PiCCO's advantages and disadvantages in liver transplantation scenarios, including its multiple parameters (such as the encompassing extravascular lung water index), against its limited correlation with PAC.


Subject(s)
Cardiac Output , Catheterization, Swan-Ganz , Hemodynamics , Liver Transplantation , Monitoring, Intraoperative , Liver Transplantation/methods , Humans , Catheterization, Swan-Ganz/methods , Cardiac Output/physiology , Male , Middle Aged , Female , Hemodynamics/physiology , Monitoring, Intraoperative/methods , Aged , Adult , Pulmonary Artery/physiology
2.
Sci Rep ; 14(1): 10504, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714788

ABSTRACT

We compared cardiovascular parameters obtained with the Mobil-O-Graph and functional capacity assessed by the Duke Activity Status Index (DASI) before and after Heart Transplantation (HT) and also compared the cardiovascular parameters and the functional capacity of candidates for HT with a control group. Peripheral and central vascular pressures increased after surgery. Similar results were observed in cardiac output and pulse wave velocity. The significant increase in left ventricular ejection fraction (LVEF) postoperatively was not followed by an increase in the functional capacity. 24 candidates for HT and 24 controls were also compared. Functional capacity was significantly lower in the HT candidates compared to controls. Stroke volume, systolic, diastolic, and pulse pressure measured peripherally and centrally were lower in the HT candidates when compared to controls. Despite the significant increase in peripheral and central blood pressures after surgery, the patients were normotensive. The 143.85% increase in LVEF in the postoperative period was not able to positively affect functional capacity. Furthermore, the lower values of LVEF, systolic volume, central and peripheral arterial pressures in the candidates for HT are consistent with the characteristics signs of advanced heart failure, negatively impacting functional capacity, as observed by the lower DASI score.


Subject(s)
Heart Transplantation , Pulse Wave Analysis , Stroke Volume , Humans , Heart Transplantation/methods , Male , Pilot Projects , Female , Middle Aged , Stroke Volume/physiology , Adult , Blood Pressure/physiology , Heart Failure/physiopathology , Heart Failure/surgery , Ventricular Function, Left/physiology , Aorta/surgery , Aorta/physiopathology , Cardiac Output/physiology
3.
PLoS One ; 19(5): e0298727, 2024.
Article in English | MEDLINE | ID: mdl-38768104

ABSTRACT

Cardiac output (CO) is one of the primary prognostic factors evaluated during the follow-up of patients treated for pulmonary hypertension (PH). It is recommended that it be measured using the thermodilution technique during right heart catheterization. The difficulty to perform iterative invasive measurements on the same individual led us to consider a non-invasive option. The aims of the present study were to assess the agreement between CO values obtained using bioreactance (Starling™ SV) and thermodilution, and to evaluate the ability of the bioreactance monitor to detect patients whose CO decreased by more than 15% during follow-up and, accordingly, its usefulness for patient monitoring. A prospective cohort study evaluating the performance of the Starling™ SV monitor was conducted in patients with clinically stable PH. Sixty patients referred for hemodynamic assessment were included. CO was measured using both the thermodilution technique and bioreactance during two follow-up visits. A total of 60 PH patients were included. All datasets were available at the baseline visit (V0) and 50 of them were usable during the follow-up visit (V1). Median [IQR] CO was 4.20 l/min [3.60-4.70] when assessed by bioreactance, and 5.30 l/min [4.57-6.20] by thermodilution (p<0.001). The Spearman correlation coefficient was 0.51 [0.36-0.64], and the average deviation on Bland-Altman plot was -1.25 l/min (95% CI [-1.48-1.01], p<0.001). The ability of the monitor to detect a variation in CO of more than 15% between two follow-up measurements, when such variation existed using thermodilution, was insufficient for clinical practice (AUC = 0.54, 95% CI [0.33-0.75]).


Subject(s)
Cardiac Output , Hypertension, Pulmonary , Thermodilution , Humans , Cardiac Output/physiology , Female , Male , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/diagnosis , Middle Aged , Thermodilution/methods , Follow-Up Studies , Prospective Studies , Aged , Reproducibility of Results , Monitoring, Physiologic/methods , Cardiac Catheterization , Adult
5.
J Physiol ; 602(10): 2227-2251, 2024 May.
Article in English | MEDLINE | ID: mdl-38690610

ABSTRACT

Passive whole-body hyperthermia increases limb blood flow and cardiac output ( Q ̇ $\dot Q$ ), but the interplay between peripheral and central thermo-haemodynamic mechanisms remains unclear. Here we tested the hypothesis that local hyperthermia-induced alterations in peripheral blood flow and blood kinetic energy modulate flow to the heart and Q ̇ $\dot Q$ . Body temperatures, regional (leg, arm, head) and systemic haemodynamics, and left ventricular (LV) volumes and functions were assessed in eight healthy males during: (1) 3 h control (normothermic condition); (2) 3 h of single-leg heating; (3) 3 h of two-leg heating; and (4) 2.5 h of whole-body heating. Leg, forearm, and extracranial blood flow increased in close association with local rises in temperature while brain perfusion remained unchanged. Increases in blood velocity with small to no changes in the conduit artery diameter underpinned the augmented limb and extracranial perfusion. In all heating conditions, Q ̇ $\dot Q$ increased in association with proportional elevations in systemic vascular conductance, related to enhanced blood flow, blood velocity, vascular conductance and kinetic energy in the limbs and head (all R2 ≥ 0.803; P < 0.001), but not in the brain. LV systolic (end-systolic elastance and twist) and diastolic functional profiles (untwisting rate), pulmonary ventilation and systemic aerobic metabolism were only altered in whole-body heating. These findings substantiate the idea that local hyperthermia-induced selective alterations in peripheral blood flow modulate the magnitude of flow to the heart and Q ̇ $\dot Q$ through changes in blood velocity and kinetic energy. Localised heat-activated events in the peripheral circulation therefore affect the human heart's output. KEY POINTS: Local and whole-body hyperthermia increases limb and systemic perfusion, but the underlying peripheral and central heat-sensitive mechanisms are not fully established. Here we investigated the regional (leg, arm and head) and systemic haemodynamics (cardiac output: Q ̇ $\dot Q$ ) during passive single-leg, two-leg and whole-body hyperthermia to determine the contribution of peripheral and central thermosensitive factors in the control of human circulation. Single-leg, two-leg, and whole-body hyperthermia induced graded increases in leg blood flow and Q ̇ $\dot Q$ . Brain blood flow, however, remained unchanged in all conditions. Ventilation, extracranial blood flow and cardiac systolic and diastolic functions only increased during whole-body hyperthermia. The augmented Q ̇ $\dot Q$ with hyperthermia was tightly related to increased limb and head blood velocity, flow and kinetic energy. The findings indicate that local thermosensitive mechanisms modulate regional blood velocity, flow and kinetic energy, thereby controlling the magnitude of flow to the heart and thus the coupling of peripheral and central circulation during hyperthermia.


Subject(s)
Cardiac Output , Hyperthermia , Humans , Male , Adult , Hyperthermia/physiopathology , Cardiac Output/physiology , Blood Flow Velocity/physiology , Regional Blood Flow/physiology , Fever/physiopathology , Young Adult , Hot Temperature , Hemodynamics
6.
BMC Anesthesiol ; 24(1): 187, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38796436

ABSTRACT

PURPOSE: Oxygen delivery (DO2) and its monitoring are highlighted to aid postoperative goal directed therapy (GDT) to improve perioperative outcomes such as acute kidney injury (AKI) after high-risk cardiac surgeries associated with multiple morbidities and mortality. However, DO2 monitoring is neither routine nor done postoperatively, and current methods are invasive and only produce intermittent DO2 trends. Hence, we proposed a novel algorithm that simultaneously integrates cardiac output (CO), hemoglobin (Hb) and oxygen saturation (SpO2) from the Edwards Life Sciences ClearSight System® and Masimo SET Pulse CO-Oximetry® to produce a continuous, real-time DO2 trend. METHODS: Our algorithm was built systematically with 4 components - machine interface to draw data with PuTTY, data extraction with parsing, data synchronization, and real-time DO2 presentation using a graphic-user interface. Hb readings were validated. RESULTS: Our algorithm was implemented successfully in 93% (n = 57 out of 61) of our recruited cardiac surgical patients. DO2 trends and AKI were studied. CONCLUSION: We demonstrated a novel proof-of-concept and feasibility of continuous, real-time, non-invasive DO2 monitoring, with each patient serving as their own control. Our study also lays the foundation for future investigations aimed at identifying personalized critical DO2 thresholds and optimizing DO2 as an integral part of GDT to enhance outcomes in perioperative cardiac surgery.


Subject(s)
Algorithms , Cardiac Surgical Procedures , Feasibility Studies , Oximetry , Oxygen , Humans , Cardiac Surgical Procedures/methods , Male , Female , Oxygen/metabolism , Oxygen/administration & dosage , Oxygen/blood , Oximetry/methods , Aged , Middle Aged , Proof of Concept Study , Acute Kidney Injury , Monitoring, Physiologic/methods , Cardiac Output/physiology , Hemoglobins/metabolism , Hemoglobins/analysis , Oxygen Saturation/physiology
7.
Curr Opin Crit Care ; 30(3): 251-259, 2024 06 01.
Article in English | MEDLINE | ID: mdl-38690954

ABSTRACT

PURPOSE OF REVIEW: To describe current and near future developments and applications of CO2 kinetics in clinical respiratory and cardiovascular monitoring. RECENT FINDINGS: In the last years, we have witnessed a renewed interest in CO2 kinetics in relation with a better understanding of volumetric capnography and its derived parameters. This together with technological advances and improved measurement systems have expanded the monitoring potential of CO2 kinetics including breath by breath continuous end-expiratory lung volume and continuous noninvasive cardiac output. Dead space has slowly been gaining relevance in clinical monitoring and prognostic evaluation. Easy to measure dead space surrogates such as the ventilatory ratio have demonstrated a strong prognostic value in patients with acute respiratory failure. SUMMARY: The kinetics of carbon dioxide describe many relevant physiological processes. The clinical introduction of new ways of assessing respiratory and circulatory efficiency based on advanced analysis of CO2 kinetics are paving the road to a long-desired goal in clinical monitoring of critically ill patients: the integration of respiratory and circulatory monitoring during mechanical ventilation.


Subject(s)
Capnography , Carbon Dioxide , Humans , Carbon Dioxide/analysis , Capnography/methods , Monitoring, Physiologic/methods , Respiration, Artificial/methods , Kinetics , Cardiac Output/physiology , Biomarkers , Respiratory Dead Space/physiology
8.
PLoS One ; 19(5): e0302793, 2024.
Article in English | MEDLINE | ID: mdl-38739601

ABSTRACT

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Subject(s)
Algorithms , Cardiac Output , Echocardiography, Doppler , Pulse Wave Analysis , Humans , Male , Female , Cardiac Output/physiology , Aged , Pulse Wave Analysis/methods , Echocardiography, Doppler/methods , Middle Aged , Aged, 80 and over , Oscillometry/methods
9.
Zhonghua Fu Chan Ke Za Zhi ; 59(5): 375-382, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38797567

ABSTRACT

Objective: To investigate the variation of reference ranges of hemodynamic parameters in normal pregnancy and their relation to maternal basic characteristics. Methods: A total of 598 healthy pregnant women who underwent regular prenatal examination at the Third Affiliated Hospital of Guangzhou Medical University from January to December 2023 were prospectively enrolled, and noninvasive hemodynamic monitors were used to detect changes in hemodynamic parameters of the pregnant women with the week of gestation, including cardiac output (CO), stroke volume (SV), thoracic fluid content (TFC), systemic vascular resistance (SVR), mean arterial pressure (MAP), and heart rate (HR). Relationships between hemodynamic parameters and maternal basic characteristics, including age, height, and weight, were analyzed using restricted cubic spline. Results: (1) CO (r=0.155, P<0.001), TFC (r=0.338, P<0.001), MAP (r=0.204, P<0.001), and HR (r=0.352, P<0.001) were positively correlated with the week of gestation, and SV was negatively correlated with the week of gestation (r=-0.158, P<0.001). There was no significant correlation between SVR and gestational age (r=-0.051, P=0.258). (2) CO exhibited a positive correlation with maternal height and weight (all P<0.001). The taller and heavier of pregnant women, the higher their CO. A linear relationship was observed between maternal weight and SV, MAP and HR (all P<0.01). As maternal weight increased, SV, MAP and HR showed an upward trend. Furthermore, there was an inverse association between maternal age and SVR (P<0.001). (3) There was a significant nonlinear association observed between TFC and body mass index during pregnancy (P<0.05). Additionally, a nonlinear relationship was found between SVR and MAP in relation to maternal age (all P<0.05). Notably, when the age exceeded 31 years old, there was an evident upward trend observed in both SVR and MAP. Conclusions: The hemodynamic parameters of normal pregnant women are influenced by their height, body weight, and age. It is advisable to maintain a reasonable weight during pregnancy and give birth at an appropriate age.


Subject(s)
Cardiac Output , Heart Rate , Hemodynamics , Stroke Volume , Vascular Resistance , Humans , Female , Pregnancy , Cardiac Output/physiology , Stroke Volume/physiology , Vascular Resistance/physiology , Prospective Studies , Heart Rate/physiology , Gestational Age , Reference Values , Adult , Blood Pressure/physiology , Arterial Pressure/physiology , Body Weight
10.
Physiol Rep ; 12(9): e16027, 2024 May.
Article in English | MEDLINE | ID: mdl-38684421

ABSTRACT

Resistance breathing may restore cardiac output (CO) and cerebral blood flow (CBF) during hypovolemia. We assessed CBF and cerebral autoregulation (CA) during tilt, resistance breathing, and paced breathing in 10 healthy subjects. Blood velocities in the internal carotid artery (ICA), middle cerebral arteries (MCA, four subjects), and aorta were measured by Doppler ultrasound in 30° and 60° semi-recumbent positions. ICA blood flow and CO were calculated. Arterial blood pressure (ABP, Finometer), and end-tidal CO2 (ETCO2) were recorded. ICA blood flow response was assessed by mixed-models regression analysis. The synchronization index (SI) for the variable pairs ABP-ICA blood velocity, ABP-MCA velocities in 0.005-0.08 Hz frequency interval was calculated as a measure of CA. Passive tilting from 30° to 60° resulted in 12% decrease in CO (p = 0.001); ICA blood flow tended to fall (p = 0.04); Resistance breathing restored CO and ICA blood flow despite a 10% ETCO2 drop. ETCO2 and CO contributed to ICA blood flow variance (adjusted R2: 0.9, p < 0.0001). The median SI was low (<0.2) indicating intact CA, confirmed by surrogate date testing. The peak SI was transiently elevated during resistance breathing in the 60° position. Resistance breathing may transiently reduce CA efficiency. Paced breathing did not restore CO or ICA blood flow.


Subject(s)
Cerebrovascular Circulation , Homeostasis , Humans , Male , Cerebrovascular Circulation/physiology , Homeostasis/physiology , Pilot Projects , Adult , Female , Blood Flow Velocity/physiology , Middle Cerebral Artery/physiology , Middle Cerebral Artery/diagnostic imaging , Cardiac Output/physiology , Healthy Volunteers , Carotid Artery, Internal/physiology , Carotid Artery, Internal/diagnostic imaging , Blood Pressure/physiology
11.
J Appl Physiol (1985) ; 136(5): 1276-1283, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38602000

ABSTRACT

In patients with chronic obstructive pulmonary disease (COPD), pulmonary vascular dysfunction and destruction are observable before the onset of detectable emphysema, but it is unknown whether this is associated with central hypovolemia. We investigated if patients with COPD have reduced pulmonary blood volume (PBV) evaluated by 82Rb-positron emission tomography (PET) at rest and during adenosine-induced hyperemia. This single-center retrospective cohort study assessed 6,301 82Rb-PET myocardial perfusion imaging (MPI) examinations performed over a 6-yr period. We compared 77 patients with COPD with 44 healthy kidney donors (controls). Cardiac output ([Formula: see text]) and mean 82Rb bolus transit time (MBTT) were used to calculate PBV. [Formula: see text] was similar at rest (COPD: 3,649 ± 120 mL vs. control: 3,891 ± 160 mL, P = 0.368) but lower in patients with COPD compared with controls during adenosine infusion (COPD: 5,432 ± 124 mL vs. control: 6,185 ± 161 mL, P < 0.050). MBTT was shorter in patients with COPD compared with controls at rest (COPD: 8.7 ± 0.28 s vs. control: 11.4 ± 0.37 s, P < 0.001) and during adenosine infusion (COPD: 9.2 ± 0.28 s vs. control: 10.2 ± 0.37 s, P < 0.014). PBV was lower in patients with COPD, even after adjustment for body surface area, sex, and age at rest [COPD: 530 (29) mL vs. 708 (38) mL, P < 0.001] and during adenosine infusion [COPD: 826 (29) mL vs. 1,044 (38) mL, P < 0.001]. In conclusion, patients with COPD show evidence of central hypovolemia, but it remains to be determined whether this has any diagnostic or prognostic impact.NEW & NOTEWORTHY The present study demonstrated that patients with chronic obstructive pulmonary disease (COPD) exhibit central hypovolemia compared with healthy controls. Pulmonary blood volume may thus be a relevant physiological and/or clinical outcome measure in future COPD studies.


Subject(s)
Blood Volume , Positron-Emission Tomography , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Male , Female , Retrospective Studies , Middle Aged , Aged , Blood Volume/physiology , Positron-Emission Tomography/methods , Lung/physiopathology , Lung/diagnostic imaging , Rubidium Radioisotopes , Myocardial Perfusion Imaging/methods , Adenosine/administration & dosage , Cardiac Output/physiology
12.
Article in English | MEDLINE | ID: mdl-38673361

ABSTRACT

Adults who have had an amputation face barriers to having an active lifestyle which attenuates cardiorespiratory fitness. Prior studies in amputees typically involve treadmill walking or arm ergometry, yet physiological responses to bilateral leg cycling are less understood. This study assessed the hemodynamic and metabolic responses to moderate and vigorous cycle ergometry in men who have had a transtibial amputation (TTA). Five men who had had a unilateral TTA (age = 39 ± 15 yr) and six controls (CONs) without an amputation (age = 31 ± 11 yr) performed two 20 min bouts of cycling differing in intensity. Cardiac output (CO), stroke volume (SV), and oxygen consumption (VO2) were measured during moderate intensity continuous exercise (MICE) and high intensity interval exercise (HIIE) using thoracic impedance and indirect calorimetry. In response to MICE and HIIE, the HR and VO2 levels were similar (p > 0.05) between groups. Stroke volume and CO were higher (p < 0.05) in the CONs, which was attributed to their higher body mass. In men with TTAs, HIIE elicited a peak HR = 88%HRmax and substantial blood lactate accumulation, representing vigorous exercise intensity. No adverse events were exhibited in the men with TTAs. The men with TTAs show similar responses to MICE and HIIE versus the CONs.


Subject(s)
Amputation, Surgical , Hemodynamics , Oxygen Consumption , Male , Humans , Adult , Middle Aged , Exercise Test , Young Adult , Tibia/surgery , Bicycling/physiology , Exercise/physiology , Cardiac Output/physiology
13.
Am J Obstet Gynecol MFM ; 6(5): 101368, 2024 May.
Article in English | MEDLINE | ID: mdl-38574856

ABSTRACT

BACKGROUND: Despite major advances in the pharmacologic treatment of hypertension in the nonpregnant population, treatments for hypertension in pregnancy have remained largely unchanged over the years. There is recent evidence that a more adequate control of maternal blood pressure is achieved when the first given antihypertensive drug is able to correct the underlying hemodynamic disorder of the mother besides normalizing the blood pressure values. OBJECTIVE: This study aimed to compare the blood pressure control in women receiving an appropriate or inappropriate antihypertensive therapy following the baseline hemodynamic findings. STUDY DESIGN: This was a prospective multicenter study that included a population of women with de novo diagnosis of hypertensive disorders of pregnancy. A noninvasive assessment of the following maternal parameters was performed on hospital admission via Ultrasound Cardiac Output Monitor before any antihypertensive therapy was given: cardiac output, heart rate, systemic vascular resistance, and stroke volume. The clinician who prescribed the antihypertensive therapy was blinded to the hemodynamic evaluation and used as first-line treatment a vasodilator (nifedipine or alpha methyldopa) or a beta-blocker (labetalol) based on his preferences or on the local protocols. The first-line pharmacologic treatment was retrospectively considered hemodynamically appropriate in either of the following circumstances: (1) women with a hypodynamic profile (defined as low cardiac output [≤5 L/min] and/or high systemic vascular resistance [≥1300 dynes/second/cm2]) who were administered oral nifedipine or alpha methyldopa and (2) women with a hyperdynamic profile (defined as normal or high cardiac output [>5 L/min] and/or low systemic vascular resistances [<1300 dynes/second/cm2]) who were administered oral labetalol. The primary outcome of the study was to compare the occurrence of severe hypertension between women treated with a hemodynamically appropriate therapy and women treated with an inappropriate therapy. RESULTS: A total of 152 women with hypertensive disorders of pregnancy were included in the final analysis. Most women displayed a hypodynamic profile (114 [75.0%]) and received a hemodynamically appropriate treatment (116 [76.3%]). The occurrence of severe hypertension before delivery was significantly lower in the group receiving an appropriate therapy than in the group receiving an inappropriately treated (6.0% vs 19.4%, respectively; P=.02). Moreover, the number of women who achieved target values of blood pressure within 48 to 72 hours from the treatment start was higher in the group who received an appropriate treatment than in the group who received an inappropriate treatment (70.7% vs 50.0%, respectively; P=.02). CONCLUSION: In pregnant individuals with de novo hypertensive disorders of pregnancy, a lower occurrence of severe hypertension was observed when the first-line antihypertensive agent was tailored to the correct maternal hemodynamic profile.


Subject(s)
Antihypertensive Agents , Hemodynamics , Labetalol , Pre-Eclampsia , Humans , Female , Pregnancy , Antihypertensive Agents/therapeutic use , Antihypertensive Agents/pharmacology , Antihypertensive Agents/administration & dosage , Prospective Studies , Adult , Hemodynamics/drug effects , Hemodynamics/physiology , Pre-Eclampsia/physiopathology , Pre-Eclampsia/drug therapy , Pre-Eclampsia/diagnosis , Labetalol/administration & dosage , Labetalol/pharmacology , Cardiac Output/drug effects , Cardiac Output/physiology , Nifedipine/pharmacology , Nifedipine/administration & dosage , Nifedipine/therapeutic use , Vascular Resistance/drug effects , Methyldopa/administration & dosage , Methyldopa/pharmacology , Methyldopa/therapeutic use , Blood Pressure/drug effects , Blood Pressure/physiology , Hypertension, Pregnancy-Induced/drug therapy , Hypertension, Pregnancy-Induced/physiopathology , Hypertension, Pregnancy-Induced/diagnosis , Treatment Outcome , Heart Rate/drug effects , Heart Rate/physiology , Stroke Volume/drug effects , Stroke Volume/physiology , Vasodilator Agents/administration & dosage , Vasodilator Agents/pharmacology , Vasodilator Agents/therapeutic use
14.
J Transl Med ; 22(1): 285, 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38493167

ABSTRACT

BACKGROUND: Lactate is traditionally recognized as a by-product of anaerobic metabolism. However, lactate is a preferred oxidative substrate for stressed myocardium. Exogenous lactate infusion increases cardiac output (CO). The exact mechanism underlying this mechanism has yet to be elucidated. The aim of this study was to investigate the cardiovascular mechanisms underlying the acute haemodynamic effects of exogenous lactate infusion in an experimental model of human-sized pigs. METHODS: In this randomised, blinded crossover study in eight 60-kg-pigs, the pigs received infusions with one molar sodium lactate and a control infusion of tonicity matched hypertonic saline in random order. We measured CO and pulmonary pressures using a pulmonary artery catheter. A pressure-volume admittance catheter in the left ventricle was used to measure contractility, afterload, preload and work-related parameters. RESULTS: Lactate infusion increased circulating lactate levels by 9.9 mmol/L (95% confidence interval (CI) 9.1 to 11.0) and CO by 2.0 L/min (95% CI 1.2 to 2.7). Afterload decreased as arterial elastance fell by  -1.0 mmHg/ml (95% CI  -2.0 to  -0.1) and systemic vascular resistance decreased by  -548 dynes/s/cm5 (95% CI  -261 to  -835). Mixed venous saturation increased by 11 percentage points (95% CI 6 to 16), whereas ejection fraction increased by 16.0 percentage points (95% CI 1.1 to 32.0) and heart rate by 21 bpm (95% CI 8 to 33). No significant changes in contractility nor preload were observed. CONCLUSION: Lactate infusion increased cardiac output by increasing heart rate and lowering afterload. No differences were observed in left ventricular contractility or preload. Lactate holds potential as a treatment in situations with lowered CO and should be investigated in future clinical studies.


Subject(s)
Hemodynamics , Lactic Acid , Animals , Cardiac Output/physiology , Cross-Over Studies , Heart Rate , Swine , Vascular Resistance
15.
Sci Rep ; 14(1): 7478, 2024 03 29.
Article in English | MEDLINE | ID: mdl-38553509

ABSTRACT

This study examined the possibility of estimating cardiac output (CO) using a multimodal stacking model that utilizes cardiopulmonary interactions during general anesthesia and outlined a retrospective application of machine learning regression model to a pre-collected dataset. The data of 469 adult patients (obtained from VitalDB) with normal pulmonary function tests who underwent general anesthesia were analyzed. The hemodynamic data in this study included non-invasive blood pressure, plethysmographic heart rate, and SpO2. CO was recorded using Vigileo and EV1000 (pulse contour technique devices). Respiratory data included mechanical ventilation parameters and end-tidal CO2 levels. A generalized linear regression model was used as the metalearner for the multimodal stacking ensemble method. Random forest, generalized linear regression, gradient boosting machine, and XGBoost were used as base learners. A Bland-Altman plot revealed that the multimodal stacked ensemble model for CO prediction from 327 patients had a bias of - 0.001 L/min and - 0.271% when calculating the percentage of difference using the EV1000 device. Agreement of model CO prediction and measured Vigileo CO in 142 patients reported a bias of - 0.01 and - 0.333%. Overall, this model predicts CO compared to data obtained by the pulse contour technique CO monitors with good agreement.


Subject(s)
Anesthesia, General , Adult , Humans , Retrospective Studies , Cardiac Output/physiology , Blood Pressure , Monitoring, Physiologic/methods , Reproducibility of Results
16.
Eur Radiol Exp ; 8(1): 51, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38517595

ABSTRACT

BACKGROUND: To validate pulmonary computed tomography (CT) perfusion in a porcine model by invasive monitoring of cardiac output (CO) using thermodilution method. METHODS: Animals were studied at a single center, using a Swan-Ganz catheter for invasive CO monitoring as a reference. Fifteen pigs were included. Contrast-enhanced CT perfusion of the descending aorta and right and left pulmonary artery was performed. For variation purposes, a balloon catheter was inserted to block the contralateral pulmonary vascular bed; additionally, two increased CO settings were created by intravenous administration of catecholamines. Finally, stepwise capillary occlusion was performed by intrapulmonary arterial injection of 75-µm microspheres in four stages. A semiautomatic selection of AFs and a recirculation-aware tracer-kinetics model to extract the first-pass of AFs, estimating blood flow with the Stewart-Hamilton method, was implemented. Linear mixed models (LMM) were developed to calibrate blood flow calculations accounting with individual- and cohort-level effects. RESULTS: Nine of 15 pigs had complete datasets. Strong correlations were observed between calibrated pulmonary (0.73, 95% confidence interval [CI] 0.6-0.82) and aortic blood flow measurements (0.82, 95% CI, 0.73-0.88) and the reference as well as agreements (± 2.24 L/min and ± 1.86 L/min, respectively) comparable to the state of the art, on a relatively wide range of right ventricle-CO measurements. CONCLUSIONS: CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by referencing the invasive CO. RELEVANCE STATEMENT: Possible clinical applications of CT perfusion for measuring CO could be in acute pulmonary thromboembolism or to assess right ventricular function to show impairment or mismatch to the left ventricle. KEY POINTS: • CT perfusion measures flow in vessels. • CT perfusion measures cumulative cardiac output in the aorta and pulmonary vessels. • CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by using the invasive CO as a reference standard.


Subject(s)
Catheterization, Swan-Ganz , Pulmonary Artery , Humans , Swine , Animals , Cardiac Output/physiology , Pulmonary Artery/diagnostic imaging , Catheterization, Swan-Ganz/methods , Perfusion , Tomography, X-Ray Computed
17.
J Physiol Sci ; 74(1): 21, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38555424

ABSTRACT

Mean circulatory filling pressure, venous return curve, and Guyton's graphical analysis are basic concepts in cardiovascular physiology. However, some medical students may not know how to view and interpret or understand them adequately. To deepen students' understanding of the graphical analysis, in place of having to perform live animal experiments, we developed an interactive cardiovascular simulator, as a self-learning tool, as a web application. The minimum closed-loop model consisted of a ventricle, an artery, resistance, and a vein, excluding venous resistance. The simulator consists of three modules: setting (parameters and simulation modes), calculation, and presentation. In the setting module, the user can interactively customize model parameters, compliances, resistance, Emax of the ventricular contractility, total blood volume, and unstressed volume. The hemodynamics are calculated in three phases: filling (late diastole), ejection (systole), and flow (early diastole). In response to the user's settings, the simulator graphically presents the hemodynamics: the pressure-volume relations of the artery, vein, and ventricle, the venous return curves, and the stroke volume curves. The mean filling pressure is calculated at approximately 7 mmHg at the initial setting. The venous return curves, linear and concave, are dependent on the venous compliance. The hemodynamic equilibrium point is marked on the crossing point of venous return curve and the stroke volume curve. Users can interactively do discovery learning, and try and confirm their interests and get their questions answered about hemodynamic concepts by using the simulator.


Subject(s)
Hemodynamics , Veins , Animals , Humans , Veins/physiology , Stroke Volume , Blood Pressure/physiology , Cardiac Output/physiology
18.
Physiol Rep ; 12(6): e15979, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38490814

ABSTRACT

Postural orthostatic tachycardia syndrome (POTS) is characterized by an excessive heart rate (HR) response upon standing and symptoms indicative of inadequate cerebral perfusion. We tested the hypothesis that during lower body negative pressure (LBNP), individuals with POTS would have larger decreases in cardiac and cerebrovascular function measured using magnetic resonance (MR) imaging. Eleven patients with POTS and 10 healthy controls were studied at rest and during 20 min of -25 mmHg LBNP. Biventricular volumes, stroke volume (SV), cardiac output (Qc), and HR were determined by cardiac MR. Cerebral oxygen uptake (VO2 ) in the superior sagittal sinus was calculated from cerebral blood flow (CBF; MR phase contrast), venous O2 saturation (SvO2 ; susceptometry-based oximetry), and arterial O2 saturation (pulse oximeter). Regional cerebral perfusion was determined using arterial spin labelling. HR increased in response to LBNP (p < 0.001) with no group differences (HC: +9 ± 8 bpm; POTS: +13 ± 11 bpm; p = 0.35). Biventricular volumes, SV, and Qc decreased during LBNP (p < 0.001). CBF and SvO2 decreased with LBNP (p = 0.01 and 0.03, respectively) but not cerebral VO2 (effect of LBNP: p = 0.28; HC: -0.2 ± 3.7 mL/min; POTS: +1.1 ± 2.0 mL/min; p = 0.33 between groups). Regional cerebral perfusion decreased during LBNP (p < 0.001) but was not different between groups. These data suggest patients with POTS have preserved cardiac and cerebrovascular function.


Subject(s)
Postural Orthostatic Tachycardia Syndrome , Humans , Postural Orthostatic Tachycardia Syndrome/diagnostic imaging , Lower Body Negative Pressure , Cardiac Output/physiology , Cerebrovascular Circulation/physiology , Heart Rate/physiology , Blood Pressure/physiology
19.
Clin Physiol Funct Imaging ; 44(4): 313-323, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38497355

ABSTRACT

OBJECTIVES: This study aimed to assess the acute impact of distinct loading breathing types and intensities on cardiac autonomic function and hemodynamic responses in healthy young adults. METHODS: A randomized, crossover trial involved 28 participants who underwent inspiratory resistive breathing, expiratory resistive breathing (ERB) and combined resistive breathing, each at 30% and 60% of maximal respiratory pressures. Data on heart rate variability (HRV) and hemodynamic parameters were collected during each trial. RESULTS: The study revealed significant main and interaction effects for both the performed task and the intensity across all measured variables (all p < 0.001). ERB at 60% load demonstrated significantly higher HRV values in the standard deviation of normal-to-normal RR intervals, the square root of the mean squared difference of successive normal-to-normal RR intervals and high-frequency power, as well as significantly lower values in heart rate, stroke volume, stroke volume index, cardiac output, cardiac index, end-diastolic volume and end-diastolic volume index, compared to other loaded protocols (all p < 0.001). CONCLUSION: These findings highlight the acute effect of type-specific and load-dependent resistive breathing on cardiac autonomic and hemodynamic functions, where ERB at 60% intensity showed the most significant cardiovagal modulation while causing the least hemodynamic alterations.


Subject(s)
Autonomic Nervous System , Cross-Over Studies , Heart Rate , Heart , Hemodynamics , Humans , Heart Rate/physiology , Male , Autonomic Nervous System/physiology , Female , Young Adult , Hemodynamics/physiology , Heart/physiology , Heart/innervation , Adult , Time Factors , Inhalation , Airway Resistance , Healthy Volunteers , Breathing Exercises/methods , Exhalation/physiology , Lung/physiology , Cardiac Output/physiology
20.
Am J Obstet Gynecol MFM ; 6(3): 101312, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38342307

ABSTRACT

BACKGROUND: The physiological changes to the cardiovascular system during pregnancy are considerable and are more pronounced in those with cardiac disease. In the general population, noninvasive hemodynamic monitoring is a valid alternative to pulmonary artery catheterization, which poses risk in the pregnant population. There is limited data on noninvasive cardiac output monitoring in pregnancy as an alternative to pulmonary artery catheterization. OBJECTIVE: We sought to compare transthoracic echocardiography with a noninvasive cardiac output monitor (NICOM, Cheetah Medical) in pregnant patients with and without cardiac disease. STUDY DESIGN: This was a prospective, open-label validation study that compared 2-dimensional transthoracic echocardiography with NICOM estimations of cardiac output in each trimester of pregnancy and the postpartum period. Participants with and without cardiac disease with a singleton gestation were included. NICOM estimations of cardiac output were derived from thoracic bioreactance and compared with 2-dimensional transthoracic echocardiography for both precision and accuracy. A mean percentage difference of ±30% between the 2 devices was considered acceptable agreement between the 2 measurement techniques. RESULTS: A total of 58 subjects were enrolled; 36 did not have cardiac disease and 22 had cardiac disease. Heart rate measurements between the 2 devices were strongly correlated in both groups, whereas stroke volume and cardiac output measurements showed weak correlation. When comparing the techniques, the NICOM device overestimated cardiac output in the control group in all trimesters and the postpartum period (mean percentage differences were 50.3%, 52.7%, 48.1%, and 51.0% in the first, second, and third trimesters and the postpartum period, respectively). In the group with cardiac disease, the mean percentage differences were 31.9%, 29.7%, 19.6%, and 35.2% for the respective timepoints. CONCLUSION: The NICOM device consistently overestimated cardiac output when compared with 2-dimensional transthoracic echocardiography at all timepoints in the control group and in the first trimester and postpartum period for the cardiovascular disease group. The physiological changes of pregnancy, specifically the mean chest circumference and total body water, may alter the accuracy of the cardiac output measurement by the NICOM device as they are currently estimated. Although NICOM has been validated for use in the critical care setting, there is insufficient data to support its use in pregnancy.


Subject(s)
Echocardiography , Heart Diseases , Pregnancy , Female , Humans , Prospective Studies , Cardiac Output/physiology , Stroke Volume/physiology , Echocardiography/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...