Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.567
Filter
1.
Card Electrophysiol Clin ; 16(2): 169-174, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749637

ABSTRACT

A 34-year-old woman presented with palpitations and paroxysmal atrial fibrillation (AF). Workup revealed anterior mitral valve prolapse with severe mitral regurgitation. She was referred for surgical repair and underwent a mitral valve replacement, tricuspid valve repair, and bi-atrial cryoMAZE procedure with left atrial appendage ligation. Her postoperative course was complicated by inferior wall myocardial infarction. She subsequently presented with palpitations and underwent electrophysiology study and ablation. This case illustrates pitfalls associated with the surgical MAZE procedure and highlights the challenges in postoperative atrial arrhythmias diagnosis and management.


Subject(s)
Atrial Fibrillation , Maze Procedure , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Adult , Diagnosis, Differential , Postoperative Complications/diagnosis , Catheter Ablation/adverse effects , Electrocardiography , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/surgery
2.
BMC Cardiovasc Disord ; 24(1): 255, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755595

ABSTRACT

BACKGROUND: Ventricular tachycardia (VT) is the primary cause of sudden cardiac death in patients with hypertrophic cardiomyopathy (HCM). However, the strategy for VT treatment in HCM patients remains unclear. This study is aimed to compare the effectiveness of catheter ablation versus antiarrhythmic drug (AAD) therapy for sustained VT in patients with HCM. METHODS: A total of 28 HCM patients with sustained VT at 4 different centers between December 2012 and December 2021 were enrolled. Twelve underwent catheter ablation (ablation group) and sixteen received AAD therapy (AAD group). The primary outcome was VT recurrence during follow-up. RESULTS: Baseline characteristics were comparable between two groups. After a mean follow-up of 31.4 ± 17.5 months, the primary outcome occurred in 35.7% of the ablation group and 90.6% of the AAD group (hazard ratio [HR], 0.29 [95%CI, 0.10-0.89]; P = 0.021). No differences in hospital admission due to cardiovascular cause (25.0% vs. 71.0%; P = 0.138) and cardiovascular cause-related mortality/heart transplantation (9.1% vs. 50.6%; P = 0.551) were observed. However, there was a significant reduction in the composite endpoint of VT recurrence, hospital admission due to cardiovascular cause, cardiovascular cause-related mortality, or heart transplantation in ablation group as compared to that of AAD group (42.9% vs. 93.7%; HR, 0.34 [95% CI, 0.12-0.95]; P = 0.029). CONCLUSIONS: In HCM patients with sustained VT, catheter ablation reduced the VT recurrence, and the composite endpoint of VT recurrence, hospital admission due to cardiovascular cause, cardiovascular cause-related mortality, or heart transplantation as compared to AAD.


Subject(s)
Anti-Arrhythmia Agents , Cardiomyopathy, Hypertrophic , Catheter Ablation , Recurrence , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Anti-Arrhythmia Agents/therapeutic use , Anti-Arrhythmia Agents/adverse effects , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Male , Female , Middle Aged , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/physiopathology , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/therapy , Treatment Outcome , Time Factors , Adult , Retrospective Studies , Risk Factors , Aged , Heart Rate , China
4.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730404

ABSTRACT

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Subject(s)
Atrial Fibrillation , Bradycardia , Cardiac Pacing, Artificial , Catheter Ablation , Heart Rate , Pacemaker, Artificial , Recurrence , Humans , Male , Female , Middle Aged , Catheter Ablation/adverse effects , Prospective Studies , Treatment Outcome , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Atrial Fibrillation/surgery , Bradycardia/diagnosis , Bradycardia/therapy , Bradycardia/physiopathology , Cardiac Pacing, Artificial/adverse effects , Time Factors , Risk Factors , Syndrome , Tachycardia/physiopathology , Tachycardia/diagnosis , Tachycardia/therapy , Tachycardia/surgery
6.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Article in English | MEDLINE | ID: mdl-38655693

ABSTRACT

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Middle Aged , Catheter Ablation/instrumentation , Catheter Ablation/methods , Catheter Ablation/adverse effects , Prospective Studies , Aged , Time Factors , Heart Rate , Action Potentials , Electrocardiography, Ambulatory/instrumentation , Recurrence , Cardiac Catheters , Predictive Value of Tests , Treatment Outcome , Imaging, Three-Dimensional , Risk Factors , Equipment Design , Electrophysiologic Techniques, Cardiac
7.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646922

ABSTRACT

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Vagus Nerve Injuries , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Male , Female , Esophagus/injuries , Esophagus/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Middle Aged , Vagus Nerve Injuries/etiology , Vagus Nerve Injuries/epidemiology , Incidence , Aged , Machine Learning , Risk Factors , Germany/epidemiology , Burns/epidemiology , Burns/etiology , Time Factors , Treatment Outcome , Pulmonary Veins/surgery , Vagus Nerve
8.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584394

ABSTRACT

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
9.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584395

ABSTRACT

AIMS: A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS: A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION: The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Treatment Outcome , Prospective Studies , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Magnetic Phenomena , Recurrence
11.
J Am Heart Assoc ; 13(8): e033740, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38597139

ABSTRACT

BACKGROUND: Periodontitis has not been recognized as a modifiable risk factor for atrial fibrillation (AF). This prospective nonrandomized study investigated whether periodontal treatment improves the AF ablation outcome. METHODS AND RESULTS: We prospectively enrolled 288 AF patients scheduled to undergo initial radiofrequency catheter ablation. Each patient underwent periodontal inflamed surface area (PISA; a quantitative index of periodontal inflammation) measurement. All eligible patients were recommended to receive periodontal treatment within the blanking period, and 97 consented. During the mean follow-up period of 507±256 days, 70 (24%) AF recurrences were documented. Patients who exhibited AF recurrences had a higher PISA than those who did not (456.8±403.5 versus 277.7±259.0 mm2, P=0.001). These patients were categorized into high-PISA (>615 mm2) and low-PISA (<615 mm2) groups according to the receiver operating characteristic analysis for AF recurrence (area under the curve, 0.611; sensitivity, 39%; specificity, 89%). A high PISA, as well as female sex, AF duration, and left atrial volume, were the statistically significant predicter for AF recurrence (hazard ratio [HR], 2.308 [95% CI, 1.234-4.315]; P=0.009). In patients with a high PISA, those who underwent periodontal treatment showed significantly fewer AF recurrences (P=0.01, log-rank test). The adjusted HR of periodontal treatment for AF recurrence was 0.393 (95% CI, 0.215-0.719; P=0.002). CONCLUSIONS: Periodontitis may serve as a modifiable risk factor for AF. PISA is a hallmark of AF recurrence, and periodontal treatment improves the AF ablation outcome, especially for those with poor periodontal condition.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Periodontitis , Humans , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Prospective Studies , Heart Atria , Catheter Ablation/adverse effects , Recurrence , Treatment Outcome
12.
Circ Arrhythm Electrophysiol ; 17(5): e012548, 2024 May.
Article in English | MEDLINE | ID: mdl-38629301

ABSTRACT

BACKGROUND: Epicardial radiofrequency catheter ablation (RFCA) of idiopathic ventricular arrhythmias (VAs) originating from the left ventricular summit (LVS) is challenging because of the anatomic barriers. On the other hand, RFCA at the endocardial sites near the earliest epicardial activation site of LVS-VAs (anatomic approach) has proven successful. The evolving trends in the approaches and outcomes of RFCA of LVS-VAs at a single center were evaluated. METHODS: We studied 88 consecutive patients with idiopathic LVS-VAs at our institute from 2009 to 2019. These patients were divided into 3 periods: 2009 to 2012 (early), 2013 to 2015 (middle), and 2016 to 2019 (recent). The data were compared among the 3 periods. RESULTS: The RFCA success rate did not significantly change from the early to middle period but significantly increased from the middle to recent period (P=0.0315). The transpericardial approach usage significantly decreased over the 3 periods. The anatomic approach usage significantly increased over the 3 periods. The use of the transpericardial approach did not affect the RFCA outcomes over the 3 periods. The success rate of the anatomic RFCA tended to increase from the early to middle period and significantly increased from the middle to recent period (P=0.0412). The number of endocardial locations where RFCA was successful increased over the 3 periods. CONCLUSIONS: Over the 10-year period, the transpericardial approach became decreasingly performed, whereas the anatomic approach became increasingly performed with a satisfactory improvement in the RFCA outcomes of LVS-VAs. The anatomic RFCA became more successful by identifying more and various endocardial locations as target sites.


Subject(s)
Catheter Ablation , Heart Ventricles , Tachycardia, Ventricular , Humans , Catheter Ablation/trends , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Male , Treatment Outcome , Heart Ventricles/physiopathology , Heart Ventricles/surgery , Retrospective Studies , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Adult , Middle Aged , Time Factors , Action Potentials , Heart Rate , Electrophysiologic Techniques, Cardiac
13.
Medicine (Baltimore) ; 103(14): e37723, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579029

ABSTRACT

INTRODUCTION: Transseptal punctures (TSPs) are widely used in left atrium and left ventricle surgery. Accidental puncture of the puncture needle into the aorta is a rare complication that is rarely reported but has serious consequences. The appropriate management of this complication remains unclear. PATIENT CONCERNS: This report describes a case of a male with the chief complaint: paroxysmal palpitation for 1 year, aggravated for 1 month. DIAGNOSIS: The electrophysiological diagnosis was atrioventricular reentrant tachycardia caused by left-side bypass. INTERVENTIONS: Radiofrequency ablation of the heart was a necessary treatment and a TSP operation was needed, in which a puncture was mistakenly believed to have entered the aorta, a series of measures were taken urgently. Although the surgical procedure in this case was a false alarm, we still initiated a series of emergency plans. Emergency measures to address the complications were effectively implemented, and the emergency measures were promptly terminated after it was clear that complications had been misjudged. OUTCOMES: At last, it was confirmed that the angiogram was a pulmonary artery image, not an aorta image. Then the atrial septal puncture operation was successfully completed, and under the guidance of the Carto system, the ablation was successfully completed. Postoperative fluoroscopy showed no complications, such as pericardial effusion. After 2 years of follow-up, there was no reoccurrence of tachycardia, and there were no complications. It is crucial that emergency procedures are terminated in a timely manner after a clear miscarriage of performance. Although accidental puncture into the aorta is urgent and serious, performing a blockage or even thoracotomy in an emergency if complications are not clearly confirmed can cause further damage to the patient and would be a definitively wrong strategy. CONCLUSION: Strict and standardized TSP operations can avoid complications. Correct judgment of the authenticity of complications is crucial, and remedial measures that may cause further damage should not be blindly adopted. The retention of the aortic guide wire can provide convenient access for further differential diagnosis and remedial treatment.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Septal Defects, Atrial , Radiofrequency Ablation , Humans , Male , Aorta/surgery , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Septal Defects, Atrial/surgery , Punctures/adverse effects , Punctures/methods , Treatment Outcome
14.
J Am Heart Assoc ; 13(9): e031795, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38664237

ABSTRACT

BACKGROUND: Transcatheter renal denervation (RDN) has had inconsistent efficacy and concerns for durability of denervation. We aimed to investigate long-term safety and efficacy of transcatheter microwave RDN in vivo in normotensive sheep in comparison to conventional radiofrequency ablation. METHODS AND RESULTS: Sheep underwent bilateral RDN, receiving 1 to 2 microwave ablations (maximum power of 80-120 W for 240 s-480 s) and 12 to 16 radiofrequency ablations (180 s-240 s) in the main renal artery in a paired fashion, alternating the side of treatment, euthanized at 2 weeks (acute N=15) or 5.5 months (chronic N=15), and compared with undenervated controls (N=4). Microwave RDN produced substantial circumferential perivascular injury compared with radiofrequency at both 2 weeks [area 239.8 (interquartile range [IQR] 152.0-343.4) mm2 versus 50.1 (IQR, 32.0-74.6) mm2, P <0.001; depth 16.4 (IQR, 13.9-18.9) mm versus 7.5 (IQR, 6.0-8.9) mm P <0.001] and 5.5 months [area 20.0 (IQR, 3.4-31.8) mm2 versus 5.0 (IQR, 1.4-7.3) mm2, P=0.025; depth 5.9 (IQR, 1.9-8.8) mm versus 3.1 (IQR, 1.2-4.1) mm, P=0.005] using mixed models. Renal denervation resulted in significant long-term reductions in viability of renal sympathetic nerves [58.9% reduction with microwave (P=0.01) and 45% reduction with radiofrequency (P=0.017)] and median cortical norepinephrine levels [71% reduction with microwave (P <0.001) and 72.9% reduction with radiofrequency (P <0.001)] at 5.5 months compared with undenervated controls. CONCLUSIONS: Transcatheter microwave RDN produces deep circumferential perivascular ablations without significant arterial injury to provide effective and durable RDN at 5.5 months compared with radiofrequency RDN.


Subject(s)
Kidney , Microwaves , Renal Artery , Sympathectomy , Animals , Microwaves/therapeutic use , Microwaves/adverse effects , Sympathectomy/methods , Sympathectomy/adverse effects , Renal Artery/innervation , Kidney/innervation , Kidney/blood supply , Sheep , Catheter Ablation/methods , Catheter Ablation/adverse effects , Time Factors , Disease Models, Animal , Blood Pressure/physiology , Female , Radiofrequency Ablation/methods , Radiofrequency Ablation/adverse effects
15.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38607938

ABSTRACT

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Recurrence , Registries , Reoperation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Male , Middle Aged , Aged , Time Factors , Switzerland/epidemiology , Risk Factors , Treatment Outcome , Prospective Studies
16.
Adv Ther ; 41(6): 2342-2351, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38656739

ABSTRACT

INTRODUCTION: Laser and radiofrequency ablation are two thermal ablation methods currently widely used to treat lower limb venous insufficiency. However, very few studies have been conducted on the use of microwaves, a form of thermal ablation, for the treatment of small saphenous vein (SSV) insufficiency. This study aimed to examine the efficacy and safety of endovenous microwave ablation (EMA) for the treatment of SSV insufficiency. METHODS: The clinical data of 126 patients (126 lower limbs) with SSV insufficiency (SSV trunk reflux time ≥ 500 ms on lower limb color Doppler ultrasound) treated at the Surgery Department of The Sixth People's Hospital of Zhuji from January 2020 to June 2022 were analyzed retrospectively; 64 patients underwent EMA and 62 underwent endovenous laser ablation (EVLA). The perioperative marker data [duration of surgery, duration of hospitalization, length of thermal ablation, duration of thermal ablation, number of incisions, and numerical pain rating scale (NPRS)], complication data [skin ecchymosis, skin burns, surgical site infection, paresthesia, deep vein thrombosis (DVT), and heat-induced thrombosis (EHIT)], venous clinical severity score (VCSS), chronic venous disease quality of life questionnaire (CIVIQ-20) before and 1, 3, 12 months after surgery, and SSV trunk occlusion rate at 12 months after surgery were compared between the two groups. RESULTS: No significant differences in the surgery or hospitalization durations were observed between the two groups. There were no significant differences in the length of the SSV that required thermal ablation between the two groups; however, the thermal ablation time was shorter in the EMA group than that in the EVLA group (6.14 ± 1.47 min vs 7.05 ± 1.16 min, P < 0.001). There were no statistical differences in the number of incisions, volume of tumescent solution used, or quantity of sclerosing foam used. The NPRS scores of the EMA group at 24 h and 72 h after surgery were significantly greater than those of the EVLA group (4.03 ± 0.98 vs 3.52 ± 1.28, P = 0.013; 3.78 ± 1.06 vs 3.15 ± 1.03, P = 0.001). Moreover, the two groups showed no significant difference in the NPRS score at 1 month (1.14 ± 0.84 vs 1.07 ± 0.75, P = 0.623). The EMA and EVLA group patients experienced similar postoperative complications. The VCSS and CIVIQ-20 score significantly improved at 1, 3, and 12 months after surgery. The VCSS and CIVIQ-20 scores were compared between the two groups at 12 months after surgery, and there were no significant differences (1.44 ± 0.63 vs 1.56 ± 0.56, P = 0.261; 24.24 ± 4.96 vs 25.19 ± 5.36, P = 0.304). There was no significant difference in the incidence of SSV trunk occlusion at 12 months after surgery between the two groups (95.31% vs 96.77%, OR 1.475; 95% CI 0.238-9.146, P = 1.000). CONCLUSION: EMA and EVLA are equally effective treatment methods for SSV insufficiency. EMA is associated with higher NPRS scores in the early postoperative period.


Subject(s)
Laser Therapy , Microwaves , Saphenous Vein , Varicose Veins , Venous Insufficiency , Humans , Female , Saphenous Vein/surgery , Male , Middle Aged , Laser Therapy/methods , Laser Therapy/adverse effects , Varicose Veins/surgery , Microwaves/therapeutic use , Retrospective Studies , Venous Insufficiency/surgery , Endovascular Procedures/methods , Treatment Outcome , Adult , Aged , Radiofrequency Ablation/methods , Radiofrequency Ablation/adverse effects , Catheter Ablation/methods , Catheter Ablation/adverse effects , Ablation Techniques/methods , Ablation Techniques/adverse effects , Quality of Life
17.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38588039

ABSTRACT

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Subject(s)
Atrial Fibrillation , Cryosurgery , Peripheral Nerve Injuries , Phrenic Nerve , Pulmonary Veins , Registries , Humans , Phrenic Nerve/injuries , Male , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Pulmonary Veins/surgery , Aged , Cryosurgery/adverse effects , Cryosurgery/methods , Prospective Studies , Incidence , Peripheral Nerve Injuries/etiology , Peripheral Nerve Injuries/epidemiology , Peripheral Nerve Injuries/prevention & control , Middle Aged , Treatment Outcome , Catheter Ablation/adverse effects
18.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38647070

ABSTRACT

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
19.
Cardiovasc Diabetol ; 23(1): 121, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38581024

ABSTRACT

BACKGROUND: This study investigates the relationship between triglyceride-glucose (TyG) index trajectories and the results of ablation in patients with stage 3D atrial fibrillation (AF). METHODS: A retrospective cohort study was carried out on patients who underwent AF Radiofrequency Catheter Ablation (RFCA) at the Cardiology Department of the Fourth Affiliated Hospital of Zhejiang University and Taizhou Hospital of Zhejiang Province from January 2016 to December 2022. The main clinical endpoint was determined as the occurrence of atrial arrhythmia for at least 30 s following a 3-month period after ablation. Using a latent class trajectory model, different trajectory groups were identified based on TyG levels. The relationship between TyG trajectory and the outcome of AF recurrence in patients was assessed through Kaplan-Meier survival curve analysis and multivariable Cox proportional hazards regression model. RESULTS: The study included 997 participants, with an average age of 63.21 ± 9.84 years, of whom 630 were males (63.19%). The mean follow-up period for the participants was 30.43 ± 17.75 months, during which 200 individuals experienced AF recurrence. Utilizing the minimum Bayesian Information Criterion (BIC) and the maximum Entropy principle, TyG levels post-AF RFCA were divided into three groups: Locus 1 low-low group (n = 791), Locus 2 low-high-low group (n = 14), and Locus 3 high-high group (n = 192). Significant differences in survival rates among the different trajectories were observed through the Kaplan-Meier curve (P < 0.001). Multivariate Cox regression analysis showed a significant association between baseline TyG level and AF recurrence outcomes (HR = 1.255, 95% CI: 1.087-1.448). Patients with TyG levels above 9.37 had a higher risk of adverse outcomes compared to those with levels below 8.67 (HR = 2.056, 95% CI: 1.335-3.166). Furthermore, individuals in Locus 3 had a higher incidence of outcomes compared to those in Locus 1 (HR = 1.580, 95% CI: 1.146-2). CONCLUSION: The TyG trajectories in patients with stage 3D AF are significantly linked to the outcomes of AF recurrence. Continuous monitoring of TyG levels during follow-up may help in identifying patients at high risk of AF recurrence, enabling the early application of effective interventions.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Male , Humans , Middle Aged , Aged , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Retrospective Studies , Bayes Theorem , Treatment Outcome , Risk Factors , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
SELECTION OF CITATIONS
SEARCH DETAIL
...