Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 16.455
Filter
2.
Int Heart J ; 65(3): 404-413, 2024.
Article in English | MEDLINE | ID: mdl-38825490

ABSTRACT

This study aimed to clarify (1) the association among the atrial fibrillation (AF) type, sleep-disordered breathing (SDB), heart failure (HF), and left atrial (LA) enlargement, (2) the independent predictors of LA enlargement, and (3) the effects of ablation on those conditions in patients with AF. The study's endpoint was LA enlargement (LA volume index [LAVI] ≥ 78 mL/m2).Of 423 patients with nonvalvular AF, 236 were enrolled. We evaluated the role of the clinical parameters such as the AF type, SDB severity, and HF in LA enlargement. Among them, 141 patients exhibiting a 3% oxygen desaturation index (ODI) of ≥ 10 events/hour underwent polysomnography to evaluate the SDB severity measured by the apnea-hypopnea index (AHI). The LA enlargement and HF were characterized by the LA diameter/LAVI, an increase in the B-type natriuretic peptide level, and a lower left ventricular ejection fraction.This study showed that non-paroxysmal AF (NPAF) rather than paroxysmal AF (PAF), the SDB severity, LA enlargement, and HF progression had bidirectional associations and exacerbated each other, which generated a vicious cycle that contributed to the LA enlargement. NPAF (OR = 4.55, P < 0.001), an AHI of ≥ 25.10 events/hour (OR = 1.55, P = 0.003), and a 3% ODI of ≥ 15.43 events/hour (OR = 1.52, P = 0.003) were independent predictors of an acceleration of the LA enlargement. AF ablation improved the HF and LA enlargement.To break this vicious cycle, AF ablation may be the basis for suppressing the LA enlargement and HF progression subsequently eliminating the substrates for AF and SDB in patients with AF.


Subject(s)
Atrial Fibrillation , Disease Progression , Heart Atria , Heart Failure , Severity of Illness Index , Sleep Apnea Syndromes , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/complications , Male , Female , Sleep Apnea Syndromes/complications , Sleep Apnea Syndromes/physiopathology , Sleep Apnea Syndromes/diagnosis , Heart Failure/physiopathology , Heart Failure/complications , Middle Aged , Aged , Heart Atria/physiopathology , Heart Atria/diagnostic imaging , Heart Atria/pathology , Catheter Ablation/methods , Polysomnography , Atrial Remodeling/physiology , Echocardiography
3.
Sci Rep ; 14(1): 12660, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831029

ABSTRACT

The optimal anesthetic agent for radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) and its impact on the recovery profiles remain uncertain. We compared the recovery and hemodynamic parameters between the remimazolam-flumazenil and propofol groups during RFCA. Patients were randomized into the remimazolam-flumazenil and propofol groups. The primary outcome measure was the time to eye opening following the discontinuation of anesthetic agents. Secondary outcomes included time to extubation, time to discharge from the operating room, intraprocedural hemodynamic variables and postoperative quality outcomes. Fifty-three patients were included in the final analysis (n = 26 in the remimazolam-flumazenil and n = 27 in the propofol group). The time to eye opening was significantly shorter in the remimazolam-flumazenil group compared to the propofol group (median [interquartile range]: 174 [157-216] vs. 353 [230-483] s, P < 0.001). The mean blood pressure and bispectral index were significantly higher in the remimazolam-flumazenil group compared to the propofol group (mean difference [95% CI], 7.2 [1.7-12.7] mmHg and 6 [3-8]; P = 0.011 and < 0.001, respectively), which were within target ranges in both groups. Other secondary outcomes were comparable between the groups. Consequently, remimazolam emerges as a promising anesthetic agent, characterized by rapid recovery and stable hemodynamics, during RFCA of AF.Trial registration: NCT05397886.


Subject(s)
Anesthesia, General , Atrial Fibrillation , Catheter Ablation , Flumazenil , Propofol , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Propofol/administration & dosage , Male , Female , Middle Aged , Catheter Ablation/methods , Flumazenil/administration & dosage , Anesthesia, General/methods , Aged , Anesthesia Recovery Period , Benzodiazepines/administration & dosage , Hemodynamics/drug effects , Anesthetics, Intravenous/administration & dosage
4.
Acta Neurochir (Wien) ; 166(1): 247, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38831111

ABSTRACT

BACKGROUND: Radiofrequency thermorhizotomy (TRZ) is an established treatment for trigeminal neuralgia (TN). TRZ can result risky and painful in a consistent subset of patients, due to the need to perform multiple trajectories, before a successful foramen ovale cannulation. Moreover, intraoperative x-rays are required. METHOD: TRZ has been performed by using a neuronavigated stylet, before trajectory planning on a dedicated workstation. CONCLUSION: Navigated-TRZ (N-TRZ) meets the expectations of a safer and more tolerable procedure due to the use of a single trajectory, avoiding critical structures. Moreover, N-TRZ is x-ray free. Efficacy outcomes are similar to those reported in literature.


Subject(s)
Neuronavigation , Rhizotomy , Trigeminal Neuralgia , Trigeminal Neuralgia/surgery , Trigeminal Neuralgia/diagnostic imaging , Humans , Rhizotomy/methods , Neuronavigation/methods , Treatment Outcome , Catheter Ablation/methods , Catheter Ablation/instrumentation , Female , Radiofrequency Ablation/methods
5.
Lakartidningen ; 1212024 Jun 04.
Article in Swedish | MEDLINE | ID: mdl-38832571

ABSTRACT

Ventricular tachycardia (VT) in patients with structural heart disease is potentially life threatening, and most patients have an indication for an implantable cardioverter-defibrillator (ICD). Catheter ablation is an effective therapeutic strategy to reduce the risk of VT recurrence and subsequent ICD therapies. However, VT ablation is a technically complex procedure with significant risks and should be performed in experienced centers with appropriate resources. While several reports on outcome and procedural risks have been published, there is currently no data from Sweden. In addition to this literature review, we have analyzed VT ablation outcome data from our center. In 2021 and 2022, 68 VT ablations were performed in 60 patients with structural heart disease. After a median follow-up of 20 months, 18 percent had recurrent VT and there were 2 major adverse events (stroke and complete atrioventricular block). Seven patients died from non-arrhythmia related causes during follow-up. A large proportion (68 percent) were subacute procedures which are associated with a higher periprocedural risk. Referral for VT ablation earlier in the course of disease progression may likely further improve outcomes.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Catheter Ablation/methods , Catheter Ablation/adverse effects , Tachycardia, Ventricular/surgery , Defibrillators, Implantable/adverse effects , Treatment Outcome , Recurrence , Male , Female , Aged , Sweden , Middle Aged , Postoperative Complications/etiology
6.
Heart Rhythm ; 21(5): 705-706, 2024 May.
Article in English | MEDLINE | ID: mdl-38692817
7.
J Vis Exp ; (206)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38709062

ABSTRACT

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Atrial Fibrillation/surgery , Esophagus/surgery , Humans , Catheter Ablation/methods , Catheter Ablation/instrumentation , Pulmonary Veins/surgery
8.
Heart Rhythm ; 21(5): 519-520, 2024 May.
Article in English | MEDLINE | ID: mdl-38692816
9.
Arq Bras Cardiol ; 121(4): e20230544, 2024.
Article in Portuguese, English | MEDLINE | ID: mdl-38695471

ABSTRACT

BACKGROUND: Ablation Index (AI) software has allowed better atrial fibrillation (AF) ablation results, but recurrence rates remain significant. Specific serum biomarkers have been associated with this recurrence. OBJECTIVES: To evaluate whether certain biomarkers could be used (either individually or combined) to predict arrhythmia recurrence after AI-guided AF ablation. METHODS: Prospective multicenter observational study of consecutive patients referred for AF ablation from January 2018 to March 2021. Hemoglobin, brain natriuretic peptide (BNP), C-reactive protein, high sensitivity cardiac troponin I, creatinine clearance, thyroid-stimulating hormone (TSH) and free thyroxine (FT4) were assessed for their ability to predict arrhythmia recurrence during follow-up. Statistical significance was accepted for p values of<0.05. RESULTS: A total of 593 patients were included - 412 patients with paroxysmal AF and 181 with persistent AF. After a mean follow-up of 24±6 months, overall single-procedure freedom from atrial arrhythmia was 76.4%. Individually, all biomarkers had no or only modest predictive power for recurrence. However, a TSH value >1.8 µUI/mL (HR=1.82 [95% CI, 1.89-2.80], p=0.006) was an independent predictor of arrhythmia recurrence. When assessing TSH, FT4 and BNP values in combination, each additional "abnormal" biomarker value was associated with a lower freedom from arrhythmia recurrence (87.1 % for no biomarker vs. 83.5% for one vs. 75.1% for two vs. 43.3% for three biomarkers, p<0.001). Patients with three "abnormal" biomarkers had a threefold higher risk of AF recurrence compared with no "abnormal" biomarker (HR=2.88 [95% CI, 1.39-5.17], p=0.003). CONCLUSIONS: When used in combination, abnormal TSH, FT4 and BNP values can be a useful tool for predicting arrhythmia recurrence after AI-guided AF ablation.


FUNDAMENTO: O software ablation index (AI) permitiu melhorar os resultados da ablação de fibrilação atrial (FA), mas as taxas de recorrência permanecem significativas. Biomarcadores séricos específicos têm sido associados a essa recorrência. OBJETIVOS: Avaliar se certos biomarcadores podem ser utilizados (individualmente ou combinados) para predizer a recorrência de FA pós ablação guiada pelo AI. MÉTODOS: Estudo multicêntrico, observacional, prospectivo de pacientes consecutivos, encaminhados para ablação de FA de janeiro de 2018 a março de 2021. Hemoglobina, peptídeo natriurético cerebral (BNP), proteína C reativa, troponina I ultrassensível, clearance de creatinina, Hormônio Tireoestimulante (TSH), e Tiroxina livre (T4) foram avaliados quanto à capacidade de prever a recorrência de arritmias durante o acompanhamento. Valores de p <0,05 foram aceitos como estatisticamente significativos. RESULTADOS: Um total de 593 pacientes foram incluídos ­ 412 com FA paroxística e 181 com FA persistente. Durante o seguimento médio de 24±6 meses, 76,4% não apresentaram recidiva após ablação. Individualmente, os biomarcadores demonstraram um valor preditivo baixo ou nulo para recorrência. No entanto, TSH >1,8 µUI/mL [HR=1,82 (IC95%, 1,89-2,80), p=0,006] foi um preditor independente de recorrência. Avaliando-se a combinação de TSH, FT4 e BNP, a adição de cada valor "anormal" foi associada a uma menor sobrevida livre de recorrência (87,1% se nenhum vs. 83,5% se um vs. 75,1% se dois vs. 43,3% se três biomarcadores, p<0,001). Doentes com três biomarcadores "anormais" apresentaram três vezes maior probabilidade de recorrência de FA, comparativamente aos que não apresentaram nenhum biomarcador "anormal" (HR=2,88 [IC95%, 1,39-5,17], p=0,003). CONCLUSÕES: Quando combinados, valores anormais de TSH, FT4 e BNP podem ser uma ferramenta útil para prever a recorrência de FA pós ablação guiada pelo AI.


Subject(s)
Atrial Fibrillation , Biomarkers , Catheter Ablation , Recurrence , Thyrotropin , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/blood , Biomarkers/blood , Male , Female , Prospective Studies , Middle Aged , Catheter Ablation/methods , Aged , Thyrotropin/blood , Natriuretic Peptide, Brain/blood , Predictive Value of Tests , C-Reactive Protein/analysis , Treatment Outcome , Thyroxine/blood , Risk Factors , Troponin I/blood
10.
Medicina (Kaunas) ; 60(5)2024 May 16.
Article in English | MEDLINE | ID: mdl-38793000

ABSTRACT

Pulsed Field Ablation (PFA) is the latest and most intriguing technology for catheter ablation of atrial fibrillation, due to its capability to generate irreversible and cardiomyocytes-selective electroporation of cell membranes by delivering microsecond-lasting high-voltage electrical fields, leading to high expectations. The first trials to assess the clinical success of PFA, reported an arrhythmia-free survival at 1-year of 78.5%, while other trials showed less enthusiastic results: 66.2% in paroxysmal and 55.1% in persistent AF. Nevertheless, real world data are encouraging. The isolation of pulmonary veins with PFA is easily achieved with 100% acute success. Systematic invasive remapping showed a high prevalence of durable pulmonary vein isolation at 75 and 90 days (range 84-96%), which were significatively lower in redo procedures (64.3%). The advent of PFA is prompting a reconsideration of the role of the autonomic nervous system in AF ablation, as PFA-related sparing of the ganglionated plexi could lead to the still undetermined effect on late arrhythmias' recurrences. Moreover, a new concept of a blanking period could be formulated with PFA, according to its different mechanism of myocardial injury, with less inflammation and less chronic fibrosis. Finally, in this review, we also compare PFA with thermal energy.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Recurrence , Atrial Fibrillation/surgery , Humans , Catheter Ablation/methods , Catheter Ablation/statistics & numerical data , Incidence , Pulmonary Veins/surgery
11.
J Am Coll Cardiol ; 83(20): 2015-2027, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749620

ABSTRACT

The identification of the pulmonary veins as a trigger source for atrial fibrillation (AF) has established pulmonary vein isolation (PVI) as a key target for AF ablation. However, PVI alone does not prevent recurrent AF in many patients, and numerous additional ablation strategies have failed to improve on PVI outcomes. This therapeutic limitation may be due, in part, to a failure to identify and intervene specifically on the pro-fibrillatory substrate within the atria and pulmonary veins. In this review paper, we highlight several emerging approaches with clinical potential that target atrial cardiomyopathy-the underlying anatomic, electrical, and/or autonomic disease affecting the atrium-in various stages of practice and investigation. In particular, we consider the evolving roles of risk factor modification, targeting of epicardial adipose tissue, tissue fibrosis, oxidative stress, and the inflammasome, along with aggressive early anti-AF therapy in AF management. Attention to combatting substrate development promises to improve outcomes in AF.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Humans , Catheter Ablation/methods , Pulmonary Veins/surgery
12.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696675

ABSTRACT

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
14.
Zhonghua Gan Zang Bing Za Zhi ; 32(4): 332-339, 2024 Apr 20.
Article in Chinese | MEDLINE | ID: mdl-38733188

ABSTRACT

Objective: To evaluate the long-term efficacy of percutaneous microwave ablation (MWA) therapy for hepatocellular carcinoma. Methods: 2054 cases with Barcelona Clinic Liver Cancer (BCLC) stage 0~B at the Fifth Medical Center of the Chinese People's Liberation Army General Hospital from January 2006 to September 2020 were retrospectively collected. All patients were followed up for at least 2 years. The primary endpoint of overall survival and secondary endpoints (tumor-related survival, disease-free survival, and postoperative complications) of patients treated with ultrasound-guided percutaneous MWA were analyzed. Kaplan-Meier method was used for stratified survival rate analysis. Fine-and-Gray competing risk model was used to analyze overall survival. Results: A total of 5 503 HCC nodules [mean tumor diameter (2.6±1.6) cm] underwent 3 908 MWAs between January 2006 and September 2020, with a median follow-up time of 45.6 (24.0 -79.2) months.The technical effectiveness rate of 5 375 tumor nodules was 97.5%. The overall survival rates at 5, 10, and 15-years were 61.6%, 38.8%, and 27.0%, respectively. The tumor-specific survival rates were 67.1%, 47.2%, and 37.7%, respectively. The free tumor survival rates were 25.8%, 15.7%, and 9.9%, respectively. The incidence rate of severe complications was 2.8% (108/3 908). Further analysis showed that the technical effectiveness and survival rate over the passing three time periods from January 2006-2010, 2011-2015, and 2016-September 2020 were significantly increased, with P < 0.001, especially for liver cancer 3.1~5.0 cm (P < 0.001). Conclusion: Microwave ablation therapy is a safe and effective method for BCLC stage 0-B, with significantly enhanced technical efficacy and survival rate over time.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Microwaves , Humans , Liver Neoplasms/surgery , Liver Neoplasms/therapy , Carcinoma, Hepatocellular/therapy , Carcinoma, Hepatocellular/surgery , Microwaves/therapeutic use , Retrospective Studies , Survival Rate , Treatment Outcome , Disease-Free Survival , Catheter Ablation/methods , Female , Postoperative Complications/epidemiology , Male , Middle Aged
15.
Med Sci Monit ; 30: e943526, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38734884

ABSTRACT

BACKGROUND A significant number of atrial fibrillation (AF) recurrences occur after initial ablation, often due to pulmonary vein reconnections or triggers from non-pulmonary veins. MATERIAL AND METHODS Patients with paroxysmal AF who underwent radiofrequency catheter ablation for the first time were enrolled. Base on propensity score matching (1: 1 matching), 118 patients were selected for an optimized workflow for the radiofrequency catheter ablation of paroxysmal AF (OWCA) group and a conventional group. Comparative analysis of the acute and 12-month clinical outcomes was conducted. Moreover, an artificial intelligence analytics platform was used to evaluate the quality of pulmonary vein isolation (PVI) circles. RESULTS PVI was successfully achieved in all patients. Incidence of first-pass isolation of bilateral PVI circles was higher (P=0.009) and acute pulmonary vein reconnections was lower (P=0.027) in the OWCA group than conventional group. The OWCA group displayed a significant reduction in the number of fractured points (P<0.001), stacked points (P=0.003), and a greater proportion of cases in which the radiofrequency index achieved the target value (P=0.003). Additionally, the contact force consistently met the force over time criteria (P<0.001) for bilateral PVI circles in the OWCA group, accompanied by a shorter operation time (P=0.017). During the 12-month follow-up period, the OWCA group exhibited a higher atrial arrhythmia-free survival rate following the initial ablation procedure than did the conventional group. CONCLUSIONS The optimized workflow for radiofrequency catheter ablation of paroxysmal AF could play a crucial role in creating higher quality PVI circles. This improvement is reflected in a significantly elevated 12-month atrial arrhythmia-free survival rate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Workflow , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Male , Middle Aged , Treatment Outcome , Pulmonary Veins/surgery , Aged , Propensity Score , Recurrence
16.
J Cardiothorac Surg ; 19(1): 290, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38750504

ABSTRACT

OBJECTIVES: This study aimed to identify the risk factors for postoperative atrial fibrillation in patients with valvular atrial fibrillation, and establish predictive models of atrial fibrillation recurrence. METHODS: Overall, 224 patients who underwent radiofrequency ablation of atrial fibrillation from November 2014 to November 2020 were included. The statistical package for social sciences, X-tile, and R-studio were used for statistical analysis. RESULTS: Patients were divided into training and validation sets according to a ratio of 3:1. The training set was analysed using univariate and multivariate Cox regression analysis and showed that preoperative uric acid > 401 µmol/L (P = 0.006), B-type natriuretic peptide > 202 ng/L (P = 0.042), hypersensitivity C-reactive protein > 6.1 mg/L (P = 0.026), erythrocyte sedimentation rate > 7.0 mm/h (P = 0.016), preoperative left atrial diameter > 48 mm (P = 0.031) were significantly correlated with the recurrence of atrial fibrillation after radiofrequency ablation in patients with valvular atrial fibrillation. In the training set, a Cox regression model of the five related factors was established using the R language. The C-index of the model was 0.82, and the area under the receiver operating characteristic curve was 0.831 (P < 0.001). Internal and external verification was performed in the training and validation sets, respectively, and both showed that the fit of the verification curve was relatively good at 3 months, 6 months, 1 year, and 3 years postoperatively. After calculating the weight of each related factor using the nomogram, a new risk predictive model (BLUCE) for postoperative atrial fibrillation was established. CONCLUSIONS: In patients with atrial fibrillation, preoperative uric acid, B-type natriuretic peptide, hypersensitivity C-reactive protein, erythrocyte sedimentation rate, and left atrial diameter are risk factors for atrial fibrillation or atrial flutter recurrence after radiofrequency ablation. The BLUCE predictive model can distinguish high-risk groups of postoperative atrial fibrillation. High-risk patients in the BLUCE model were more likely to experience recurrence of atrial fibrillation after radiofrequency ablation and a low possibility of maintaining sinus rhythm.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Valve Diseases , Mitral Valve , Recurrence , Humans , Atrial Fibrillation/surgery , Male , Female , Middle Aged , Heart Valve Diseases/surgery , Mitral Valve/surgery , Catheter Ablation/methods , Risk Factors , Retrospective Studies , Aged , Radiofrequency Ablation/methods , Risk Assessment/methods
18.
Ther Umsch ; 81(2): 54-59, 2024 Apr.
Article in German | MEDLINE | ID: mdl-38780211

ABSTRACT

INTRODUCTION: Arrhythmias manifest frequently in individuals with heart failure, posing a notable threat of mortality and morbidity. While the prevention of sudden cardiac death through ICD therapy remains pivotal, accurate risk stratification remains a challenging task even in 2024. Recent data underscore the early consideration of catheter ablation for ventricular tachycardias. Although antiarrhythmic drug therapy serves as an ancillary measure for symptomatic patients, it does not confer prognostic advantages. The holistic management of arrhythmias in heart failure necessitates a systematic, multidimensional approach that initiates with evidence-based medical therapy for heart failure and integrates device-based and interventional therapies. Noteworthy clinical studies have illustrated the positive prognostic impact of early rhythm control strategies, particularly catheter ablation, in individuals managing heart failure and atrial fibrillation.


Subject(s)
Catheter Ablation , Heart Failure , Heart Failure/therapy , Heart Failure/diagnosis , Humans , Catheter Ablation/methods , Anti-Arrhythmia Agents/therapeutic use , Defibrillators, Implantable , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Prognosis , Combined Modality Therapy , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnosis , Atrial Fibrillation/complications , Evidence-Based Medicine , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/diagnosis
19.
Rev Assoc Med Bras (1992) ; 70(4): e2023D704, 2024.
Article in English | MEDLINE | ID: mdl-38747880

ABSTRACT

The Guidelines Project, which is an initiative of the Brazilian Medical Association, aims to combine information from the medical field to standardize how to conduct and assist in the reasoning and decision-making of doctors. The information provided by this project must be critically evaluated by the physician responsible for the conduct that will be adopted, depending on the conditions and the clinical condition of each patient.


Subject(s)
Hypertension , Kidney , Humans , Hypertension/surgery , Kidney/innervation , Treatment Outcome , Sympathectomy/methods , Catheter Ablation/methods
20.
Int J Mol Sci ; 25(9)2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38731908

ABSTRACT

In atrial fibrillation (AF), multifactorial pathologic atrial alterations are manifested by structural and electrophysiological changes known as atrial remodeling. AF frequently develops in the context of underlying cardiac abnormalities. A critical mechanistic role played by atrial stretch is played by abnormal substrates in a number of conditions that predispose to AF, including obesity, heart failure, hypertension, and sleep apnea. The significant role of overweight and obesity in the development of AF is known; however, the differential effect of overweight, obesity, cardiovascular comorbidities, lifestyle, and other modifiable risk factors on the occurrence and recurrence of AF remains to be determined. Reverse remodeling of the atrial substrate and subsequent reduction in the AF burden by conversion into a typical sinus rhythm has been associated with weight loss through lifestyle changes or surgery. This makes it an essential pillar in the management of AF in obese patients. According to recently published research, microRNAs (miRs) may function as post-transcriptional regulators of genes involved in atrial remodeling, potentially contributing to the pathophysiology of AF. The focus of this review is on their modulation by both weight loss and catheter ablation interventions to counteract atrial remodeling in AF. Our analysis outlines the experimental and clinical evidence supporting the synergistic effects of weight loss and catheter ablation (CA) in reversing atrial electrical and structural remodeling in AF onset and in recurrent post-ablation AF by attenuating pro-thrombotic, pro-inflammatory, pro-fibrotic, arrhythmogenic, and male-sex-associated hypertrophic remodeling pathways. Furthermore, we discuss the promising role of miRs with prognostic potential as predictive biomarkers in guiding approaches to AF recurrence prevention.


Subject(s)
Atrial Fibrillation , Biomarkers , Catheter Ablation , MicroRNAs , Weight Loss , Atrial Fibrillation/metabolism , Atrial Fibrillation/genetics , Atrial Fibrillation/etiology , Humans , MicroRNAs/genetics , MicroRNAs/metabolism , Catheter Ablation/methods , Recurrence , Atrial Remodeling , Animals , Obesity/metabolism , Obesity/complications
SELECTION OF CITATIONS
SEARCH DETAIL
...