Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.785
Filter
1.
G Ital Nefrol ; 41(2)2024 Apr 29.
Article in Italian | MEDLINE | ID: mdl-38695226

ABSTRACT

In patients on peritoneal dialysis, the cutaneous emergency (exit-site) represents a potential access route to the peritoneum; consequently, it can become a site for microbial infections. These infections, initially localized to the exit-site, may spread to the peritoneum causing peritonitis, which is the most common cause of drop-out from peritoneal dialysis and transition to hemodialysis. Peritoneal catheters have dacron caps which have the function of counteracting the traction of the catheter itself and at the same time acting as a barrier for microorganisms, preventing the spread towards the peritoneum. Despite this, the same dacron cap can represent a sort of nest for microorganisms to colonize and, with the formation of a biofilm that facilitates their proliferation, make the same organisms impervious to antibiotic therapy and even resistance to them. The most effective tool for monitoring the health status of the exit-site is represented by the objective examination. This examination, through the use of well-defined scales, helps to provide a pathological score of the exit, facilitating the implementation of necessary precautions. In the presence of recurrent exit-site infections, from both Gram positive and Gram negative bacteria, minimally invasive surgical therapy is a valid approach to break this vicious circle. It helps avoid subjecting the patient to the removal of the peritoneal catheter, temporary transition to hemodialysis with the insertion of a central venous catheter, and subsequent repositioning of another peritoneal catheter. We propose the case of a recurrent Staphylococcus Aureus infection resolved after cuff shaving of the exit-site.


Subject(s)
Catheter-Related Infections , Catheters, Indwelling , Peritoneal Dialysis , Recurrence , Humans , Peritoneal Dialysis/adverse effects , Peritoneal Dialysis/instrumentation , Catheter-Related Infections/microbiology , Catheter-Related Infections/prevention & control , Catheter-Related Infections/etiology , Catheters, Indwelling/adverse effects , Catheters, Indwelling/microbiology , Peritonitis/microbiology , Peritonitis/etiology , Male
2.
Pol Merkur Lekarski ; 52(2): 137-144, 2024.
Article in English | MEDLINE | ID: mdl-38642348

ABSTRACT

OBJECTIVE: Aim: to investigate the epidemiology, microbiology, and risk factors for healthcare-associated infections (HAIs) in postoperative patients with intracranial aneurysm in Ukraine. PATIENTS AND METHODS: Materials and Methods: Retrospective cohort study was conducted from January 2018 to December 2022 in four tertiary care hospitals of Ukraine. The diagnostic criteria were based on specific HAI site were adapted from the CDC/NHSN case definitions. RESULTS: Results: Of 1,084 postoperative patients with intracranial aneurysm, 128 (11.4%) HAIs were observed. The most common of HAI type was possible ventilatorassociated pneumonia (38.2%) followed by central line-associated bloodstream infections (33.8%), catheter -associated urinary tract infection (18.5%), and surgical site infection (9.6%). Inpatient mortality from HAI was 5.1%. Emergency admission, mechanical ventilation, taking antiplatelet aggregation drugs, albumin reduction, hyperglycaemia, hyponatremia, surgical procedure, operation time > 4 h, mechanical ventilation, urinary catheter, and central venous catheterization were risk factors associated with HAI in patients with intracranial aneurysm surgery. A total of 26% cases of HAIs by MDROs were notified over the study period. Klebsiella spp. - essentially K. pneumoniae - were the most frequent, followed by Enterobacter spp. and Escherichia coli. Carbapenemase production in Enterobacterales constituted the most frequent mechanism of resistance, while ESBL-production in Enterobacterales and meticillin-resistance in Staphylococcus aureus (MRSA) were detected in 65,7% 62,3% and 20% of cases, respectively. CONCLUSION: Conclusions: The present study showed that HAIs is a common complication in postoperative patients with intracranial aneurysm in Ukraine and multidrugresistant organisms the major pathogen causing infection.


Subject(s)
Catheter-Related Infections , Cross Infection , Intracranial Aneurysm , Urinary Tract Infections , Humans , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Retrospective Studies , Ukraine/epidemiology , Intracranial Aneurysm/epidemiology , Intracranial Aneurysm/surgery , Cross Infection/epidemiology , Cross Infection/microbiology , Delivery of Health Care , Anti-Bacterial Agents
3.
Antimicrob Resist Infect Control ; 13(1): 38, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38600526

ABSTRACT

BACKGROUND: Most surveillance systems for catheter-related bloodstream infections (CRBSI) and central line-associated bloodstream infections (CLABSI) are based on manual chart review. Our objective was to validate a fully automated algorithm for CRBSI and CLABSI surveillance in intensive care units (ICU). METHODS: We developed a fully automated algorithm to detect CRBSI, CLABSI and ICU-onset bloodstream infections (ICU-BSI) in patients admitted to the ICU of a tertiary care hospital in Switzerland. The parameters included in the algorithm were based on a recently performed systematic review. Structured data on demographics, administrative data, central vascular catheter and microbiological results (blood cultures and other clinical cultures) obtained from the hospital's data warehouse were processed by the algorithm. Validation for CRBSI was performed by comparing results with prospective manual BSI surveillance data over a 6-year period. CLABSI were retrospectively assessed over a 2-year period. RESULTS: From January 2016 to December 2021, 854 positive blood cultures were identified in 346 ICU patients. The median age was 61.7 years [IQR 50-70]; 205 (24%) positive samples were collected from female patients. The algorithm detected 5 CRBSI, 109 CLABSI and 280 ICU-BSI. The overall CRBSI and CLABSI incidence rates determined by automated surveillance for the period 2016 to 2021 were 0.18/1000 catheter-days (95% CI 0.06-0.41) and 3.86/1000 catheter days (95% CI: 3.17-4.65). The sensitivity, specificity, positive predictive and negative predictive values of the algorithm for CRBSI, were 83% (95% CI 43.7-96.9), 100% (95% CI 99.5-100), 100% (95% CI 56.5-100), and 99.9% (95% CI 99.2-100), respectively. One CRBSI was misclassified as an ICU-BSI by the algorithm because the same bacterium was identified in the blood culture and in a lower respiratory tract specimen. Manual review of CLABSI from January 2020 to December 2021 (n = 51) did not identify any errors in the algorithm. CONCLUSIONS: A fully automated algorithm for CRBSI and CLABSI detection in critically-ill patients using only structured data provided valid results. The next step will be to assess the feasibility and external validity of implementing it in several hospitals with different electronic health record systems.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Cross Infection , Sepsis , Humans , Female , Middle Aged , Cross Infection/epidemiology , Cross Infection/microbiology , Prospective Studies , Retrospective Studies , Catheter-Related Infections/diagnosis , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Catheters , Algorithms
4.
JPEN J Parenter Enteral Nutr ; 48(4): 486-494, 2024 May.
Article in English | MEDLINE | ID: mdl-38605559

ABSTRACT

BACKGROUND: Children with chronic IF require long-term home parenteral nutrition (HPN), administered through a central venous catheter. Catheter-related bloodstream infection (CRBSI) with Staphylococcus aureus is known to be a serious infection with a high mortality rate and risk of complications. A standardized protocol on the management of S aureus CRBSIs in children receiving HPN is lacking. The aim of this study is to evaluate the effectiveness and safety of the current management in an HPN expertise center in the Netherlands. METHODS: We performed a retrospective descriptive cohort study between 2013 and 2022 on children 0-18 years of age with chronic IF requiring long-term HPN. Our primary outcomes were the incidence of S aureus CRBSI per 1000 catheter days, catheter salvage attempt rate, and successful catheter salvage rate. Our secondary outcomes included complications and mortality. RESULTS: A total of 74 patients (39 male; 53%) were included, covering 327.8 catheter years. Twenty-eight patients (38%) had a total of 52 S aureus CRBSIs, with an incidence rate of 0.4 per 1000 catheter days. The catheter salvage attempt rate was 44% (23/52). The successful catheter salvage rate was 100%. No relapse occurred, and no removal was needed after catheter salvage. All complications that occurred were already present at admission before the decision to remove the catheter or not. No patients died because of an S aureus CRBSI. CONCLUSION: Catheter salvage in S aureus CRBSIs in children receiving HPN can be attempted after careful consideration by a multidisciplinary team in an HPN expertise center.


Subject(s)
Catheter-Related Infections , Intestinal Failure , Parenteral Nutrition, Home , Staphylococcal Infections , Staphylococcus aureus , Taurine/analogs & derivatives , Thiadiazines , Humans , Parenteral Nutrition, Home/methods , Parenteral Nutrition, Home/adverse effects , Male , Catheter-Related Infections/prevention & control , Catheter-Related Infections/microbiology , Catheter-Related Infections/epidemiology , Retrospective Studies , Female , Child , Child, Preschool , Infant , Staphylococcal Infections/prevention & control , Adolescent , Netherlands , Intestinal Failure/therapy , Infant, Newborn , Central Venous Catheters/adverse effects , Central Venous Catheters/microbiology , Chronic Disease , Incidence , Device Removal , Cohort Studies , Catheterization, Central Venous/adverse effects , Catheters, Indwelling/adverse effects , Catheters, Indwelling/microbiology , Bacteremia/prevention & control , Bacteremia/epidemiology , Bacteremia/etiology
5.
Front Cell Infect Microbiol ; 14: 1367016, 2024.
Article in English | MEDLINE | ID: mdl-38681224

ABSTRACT

Introduction: Staphylococcus aureus, is a pathogen commonly encountered in both community and hospital settings. Patients receiving hemodialysis treatment face an elevated risk of vascular access infections (VAIs) particularly Staphylococcus aureus, infection. This heightened risk is attributed to the characteristics of Staphylococcus aureus, , enabling it to adhere to suitable surfaces and form biofilms, thereby rendering it resistant to external interventions and complicating treatment efforts. Methods: Therefore this study utilized PCR and microtiter dish biofilm formation assay to determine the difference in the virulence genes and biofilm formation among in our study collected of 103 Staphylococcus aureus, isolates from hemodialysis patients utilizing arteriovenous grafts (AVGs), tunneled cuffed catheters (TCCs), and arteriovenous fistulas (AVFs) during November 2013 to December 2021. Results: Our findings revealed that both MRSA and MSSA isolates exhibited strong biofilm production capabilities. Additionally, we confirmed the presence of agr types and virulence genes through PCR analysis. The majority of the collected isolates were identified as agr type I. However, agr type II isolates displayed a higher average number of virulence genes, with MRSA isolates exhibiting a variety of virulence genes. Notably, combinations of biofilm-associated genes, such as eno-clfA-clfB-fib-icaA-icaD and eno-clfA-clfB-fib-fnbB-icaA-icaD, were prevalent among Staphylococcus aureus, isolates obtained from vascular access infections. Discussion: These insights contribute to a better understanding of the molecular characteristics associated with Staphylococcus aureus, infections in hemodialysis patients and provided more targeted and effective treatment approaches.


Subject(s)
Bacterial Proteins , Biofilms , Renal Dialysis , Staphylococcal Infections , Staphylococcus aureus , Trans-Activators , Virulence Factors , Female , Humans , Male , Middle Aged , Bacterial Proteins/genetics , Bacterial Proteins/metabolism , Biofilms/growth & development , Catheter-Related Infections/microbiology , Methicillin-Resistant Staphylococcus aureus/genetics , Methicillin-Resistant Staphylococcus aureus/pathogenicity , Renal Dialysis/adverse effects , Staphylococcal Infections/microbiology , Staphylococcus aureus/genetics , Staphylococcus aureus/pathogenicity , Trans-Activators/genetics , Virulence Factors/genetics
6.
BMJ Case Rep ; 17(4)2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38688568

ABSTRACT

Catheter-related bloodstream infection (CRBSI) is one of the common healthcare-acquired infections imposing a high burden of morbidity and mortality on the patients. Non-tuberculous mycobacterium is a rare aetiology for CRBSI and poses challenges in laboratory diagnosis and clinical management. This is a case of a woman in her early 60s with underlying end-stage renal failure, diabetes mellitus and hypertension presented with a 2-week history of high-grade fever postregular haemodialysis, vomiting, lethargy and altered mental status.Blood cultures from a permanent catheter and peripheral taken concurrently yielded Mycobacterium senegalense, identified by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry, which established the diagnosis of CRBSI atypically presented with concurrent acute intracranial bleeding and cerebrovascular infarction at initial presentation. She was started on a combination of oral azithromycin, oral amikacin and intravenous imipenem, and the permanent catheter was removed. Despite the treatments instituted, she developed septicaemia, acute myocardial infarction and macrophage activation-like syndrome, causing the patient's death.


Subject(s)
Anti-Bacterial Agents , Catheter-Related Infections , Mycobacterium Infections, Nontuberculous , Humans , Female , Catheter-Related Infections/microbiology , Catheter-Related Infections/diagnosis , Catheter-Related Infections/drug therapy , Mycobacterium Infections, Nontuberculous/diagnosis , Mycobacterium Infections, Nontuberculous/drug therapy , Middle Aged , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/administration & dosage , Fatal Outcome , Bacteremia/drug therapy , Bacteremia/diagnosis , Bacteremia/microbiology , Renal Dialysis , Kidney Failure, Chronic/therapy , Kidney Failure, Chronic/complications , Amikacin/therapeutic use , Amikacin/administration & dosage
7.
J Pediatr Gastroenterol Nutr ; 78(4): 918-926, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38451061

ABSTRACT

OBJECTIVES: Patients with intestinal failure require central venous access which puts them at risk for central line-associated bloodstream infections (CLABSI). Maintaining vascular patency is critical for this population to receive nutrition support. When CLABSIs occur line salvage can help maintain vascular access. The aim of this study is to assess factors associated with safe and successful central venous catheter salvage. METHODS: Retrospective cohort study of patients with intestinal failure at two tertiary care institutions between 2012 and 2020. The study examined the rates of attempted salvage, factors associated with successful salvage, and complications associated with salvage attempts. RESULTS: Over the study period, 76 patients with intestinal failure were include while central venous access was in place. There were a total of 94 CLABSIs. Salvage was more likely to be attempted when patients were under the direct care of an intestinal rehabilitation service (95% vs. 68%, p = 0.04). The overall successful salvage rate was 91.6% (n = 77). Gram-positive, Gram-negative, and polymicrobial infections had successful salvage rates of 97%, 92%, and 94% respectively. The successful salvage rate for fungal infections was 40%. There was no difference in 30-day complication rates for hospital readmission, intensive care unit admission, and death between patients who underwent salvage attempt and those who did not. CONCLUSIONS: Central line salvage can be safely attempted for many infections in patients with intestinal failure, leading to vascular access preservation.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Central Venous Catheters , Intestinal Diseases , Intestinal Failure , Sepsis , Humans , Child , Retrospective Studies , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Intestinal Diseases/therapy , Intestinal Diseases/complications , Central Venous Catheters/adverse effects , Central Venous Catheters/microbiology , Catheterization, Central Venous/adverse effects
8.
Medicine (Baltimore) ; 103(12): e37184, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38518044

ABSTRACT

To investigate the incidence, risk factors, and pathogenic characteristics of catheter-related bloodstream infection caused by peripherally inserted central venous catheter in neonates, and to provide references for reducing the infection rate of peripherally inserted central venous catheter. The clinical data of 680 neonates who underwent peripherally inserted central catheter (PICC) in the neonatal intensive care unit from June 2020 to June 2023 were retrospectively analyzed. The risk factors and independent risk factors of catheter-related bloodstream infection caused by PICC were determined by univariate and multivariate analysis, respectively. Catheter-related bloodstream infection occurred in 38 of 680 neonates who underwent PICC. The infection rate was 4.74%. The proportions of fungi, gram-positive bacteria, and gram-negative bacteria were 42.11%, 36.84%, and 21.05%, respectively. Candida parapsilosis was the main fungus (18.42%), coagulase negative Staphylococcus was the main gram-positive bacteria (23.68%), and Klebsiella pneumoniae and Escherichia coli were the main gram-negative bacteria (7.89%). Univariate analysis showed that gestational age ≤32 weeks, birth weight ≤1500 g, congenital diseases, nutritional support, catheterization time, 5-minute APGAR score ≤7, and neonatal respiratory distress syndrome were associated with catheter-related bloodstream infection caused by PICC. Multivariate analysis showed that premature delivery, low birth weight, parenteral nutrition, long catheterization time, and 5-minute APGAR score ≤7 were associated with catheter-related bloodstream infection caused by PICC. Among the pathogens detected, there were 6 cases of K pneumoniae, 5 cases of coagulase negative staphylococci, and 2 cases of fungi. Low birth weight, premature delivery, off-site nutrition, long catheterization time, and 5-minute APGAR score ≤7 are independent risk factors for catheter-related bloodstream infection in neonates with peripherally inserted central venous catheters. The pathogenic bacteria are fungi and multidrug-resistant bacteria.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Central Venous Catheters , Sepsis , Infant, Newborn , Humans , Infant , Retrospective Studies , Coagulase , Catheter-Related Infections/microbiology , Sepsis/etiology , Catheterization, Peripheral/adverse effects , Risk Factors , Catheterization, Central Venous/adverse effects
9.
Expert Rev Med Devices ; 21(3): 207-216, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38445649

ABSTRACT

INTRODUCTION: More than 30% of peripherally inserted central catheters (PICCs) and midline catheters experience complications. Most complications are related to thrombotic cellular adherence to catheter materials. AREAS COVERED: This manuscript outlines PICC and midline catheter complications, the need to reduce complications and how hydrogel catheters may provide a solution to address these unmet needs based on available evidence. EXPERT OPINION: Patients commonly require PICC or midline catheters for treatment to establish a reliable form of intravenous access. Catheters, while reliable in most cases, are not without complications, including occlusion, thrombosis and infection, each related to cellular adherence to the catheter material. Hydrophilic catheter coatings and composites have been developed to mitigate these thrombotic complications, reduce adherence of blood and bacterial cells to catheters and provide greater patient safety with these devices. Hydrogel materials are highly biocompatible and have been effective in reducing cellular adherence and the formation of biofilms on surfaces. Smooth hydrophilic catheter surfaces are potentially more comfortable for the patient, with reduced friction during insertion and removal. A catheter constructed of hydrophilic biomaterial, a hydrogel composite material, may minimize thrombotic complications in PICC and midline catheters, improving catheter performance and outcomes for patients.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Thrombosis , Humans , Catheterization, Central Venous/adverse effects , Catheter-Related Infections/microbiology , Hydrogels , Catheters , Thrombosis/etiology , Catheterization, Peripheral/adverse effects , Risk Factors , Retrospective Studies , Catheters, Indwelling/adverse effects
10.
Wiad Lek ; 77(1): 17-24, 2024.
Article in English | MEDLINE | ID: mdl-38431802

ABSTRACT

OBJECTIVE: Aim: To investigate the epidemiology, microbiology, and risk factors for healthcare-associated infections (HAIs) after a neurosurgical procedure in Ukraine. PATIENTS AND METHODS: Materials and Methods: Prospective multicentre surveillance was conducted from January 2020 to December 2022 in 10 regional hospitals of Ukraine. Definitions of HAIs were adapted from the Centers for Disease Control and Prevention's National Healthcare Safety Network. RESULTS: Results: Of 8,623 neurosurgical patients, 1,579 (18.3%) HAIs were observed. The most frequently of HAI types were pneumonia (38.4%), surgical site infection (34.2%), urinary tract infection (18.1%) and bloodstream infection (9.3%). Death during hospitalization was reported in 11.3% of HAI cases. There was an association between HAIs after neurosurgical procedures and patients with diabetes mellitus, end-stage renal disease undergoing dialysis, and leukaemia. The strongest independent associations were observed for intubation, urinary catheters, and vascular catheters. Klebsiella pneumoniae were most commonly reported, accounting for 25.1% of all organisms, followed by Escherichia coli (17.6%), Staphylococcus aureus (9.9%), Pseudomonas aeruginosa (8.9%), Acinetobacter baumannii (8.5%), coagulase-negative staphylococci (6.8%), and Streptococcus spp. (5.5%). In total, 76.3% isolates from neurosurgical patients were MDROs. Antimicrobial resistance in Ukraine varies greatly by bacterial species, antimicrobial group, and region. CONCLUSION: Conclusions: Healthcare-associated infections are a cause for mortality and morbidity among neurosurgical patients. This is due to increase emergence of antimicrobial-resistant pathogens. Routinely collected surveillance data are of great value as a basis for studying the consequences of HAIs.


Subject(s)
Anti-Infective Agents , Catheter-Related Infections , Cross Infection , Urinary Tract Infections , Humans , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Prospective Studies , Ukraine/epidemiology , Cross Infection/epidemiology , Cross Infection/microbiology , Urinary Tract Infections/etiology , Urinary Tract Infections/microbiology , Neurosurgical Procedures , Anti-Bacterial Agents/pharmacology , Drug Resistance, Bacterial
11.
Infect Dis (Lond) ; 56(6): 441-450, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38407125

ABSTRACT

INTRODUCTION: The epidemiological evolution of bloodstream infections (BSIs) in the last decade is not clearly defined. Our aim was to analyze the changes in the workload in our institution and to describe the evolution of the incidence and etiology of BSIs in a 12-year period, including the COVID-19 pandemic. METHODS: All blood cultures received in the laboratory of a tertiary general hospital between 2010 and 2021 were analyzed. Bloodstream infection episodes refer to each episode of bacteremia or fungemia in each patient. Incidence rates per 1000 admissions and per 100,000 population were calculated. RESULTS: No significant changes in the incidence of BSI episodes/1000 admissions were observed (mean, 31.1), while estimated population-based incidences showed declining trends (mean, 182.8/100,000 inhabitants). There was a slight increase in BSI episodes per 1000 admissions caused by Gram-negatives (mean, 16.6/1000 admissions) and E. coli was the most frequent pathogen (mean, 8.5/1000 admissions). There was no significant rise in episodes caused by ESBL- and carbapenemase-producing E. coli or K. pneumoniae, with a decline in those caused by methicillin-resistant S. aureus. A spike in BSI episodes, fungal BSIs and catheter-related infections was detected in 2020, during the COVID-19 outbreak. CONCLUSIONS: No clear increase in the incidence of BSI episodes was detected in our center over this period. Gram-negatives are the most frequent etiology, with no clear rise in antimicrobial resistance phenotypes. The COVID-19 pandemic accounted for a small increase in BSI episodes in 2020, probably related to the increase of catheter-related infections.


Subject(s)
Bacteremia , COVID-19 , Fungemia , Humans , Incidence , COVID-19/epidemiology , Bacteremia/epidemiology , Bacteremia/microbiology , Male , Female , Aged , Middle Aged , Fungemia/epidemiology , Fungemia/microbiology , SARS-CoV-2 , Adult , Aged, 80 and over , Tertiary Care Centers/statistics & numerical data , Retrospective Studies , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology
12.
J Vasc Interv Radiol ; 35(5): 751-758, 2024 May.
Article in English | MEDLINE | ID: mdl-38342222

ABSTRACT

PURPOSE: To assess the incidence of fever at diagnosis in children with leukemia and determine if fever at diagnosis is a predictor of bloodstream infection (BSI) or central venous access device (CVAD) removal for infection either within the first 30 days or between 30 and 90 days after CVAD insertion. MATERIALS AND METHODS: One hundred fifty-one patients with acute leukemia (July 1, 2018, to December 31, 2020) who underwent a CVAD insertion within 2 weeks of diagnosis were included. Patient data included demographic characteristics, fever at diagnosis, CVAD type, antibiotics before and/or on the day of CVAD insertion, BSI incidence, BSI rates per 1,000 catheter days, and need for catheter removal after CVAD insertion within 30 days and between 30 and 90 days. RESULTS: Patients with fever at diagnosis had a significantly higher incidence of BSI within the first 30 days after CVAD insertion (17/23) than that among patients without fever (6/23) (P = .046) at diagnosis. No statistically significant difference was observed in the incidence of BSI between 30 and 90 days after CVAD insertion between patients with fever (5/11) and those without fever at diagnosis (6/11) (P = .519). Fever at diagnosis was not a predictor of CVAD removal within 30 days (9 patients required CVAD removal; 7/9 had fever and 2/9 had no fever) (P = .181) or between 30 and 90 days (4 patients required CVAD removal; 1/4 had fever and 3/4 had no fever at diagnosis) (P = .343) after insertion. CONCLUSIONS: Fever at diagnosis in patients with leukemia is not a predictor of CVAD removal for infection.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Central Venous Catheters , Device Removal , Fever , Humans , Male , Female , Child , Child, Preschool , Catheter-Related Infections/diagnosis , Catheter-Related Infections/microbiology , Catheter-Related Infections/epidemiology , Incidence , Time Factors , Fever/diagnosis , Fever/etiology , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Retrospective Studies , Risk Factors , Adolescent , Central Venous Catheters/adverse effects , Infant , Risk Assessment , Leukemia/therapy , Leukemia/complications , Treatment Outcome , Age Factors , Predictive Value of Tests , Bacteremia/diagnosis , Bacteremia/epidemiology
13.
Indian J Med Microbiol ; 48: 100534, 2024.
Article in English | MEDLINE | ID: mdl-38367805

ABSTRACT

BACKGROUND: Device-associated CNS infections is a major subgroup of healthcare associated CNS infections. Healthcare-associated ventriculitis or meningitis differs considerably from community-acquired meningitis in its epidemiology, pathogenesis, clinical presentation and management. OBJECTIVES: This study aimed to identify the infection rates, the associated risk factors, and outcomes of these life-threatening infections. METHODS: This was a 2-year single center prospective cohort study. Patient's clinical data, laboratory parameters, treatment and their outcomes were collected using data collection tool, and device days were collected from the hospital information system (HIS). Patients were categorised using IDSA criteria as contamination or colonisation or infection. Cox regression model was used for multivariate analysis to estimate hazard risk. RESULTS: A total of 578 CSF diversion catheters were inserted in 472 patients. The average rate for EVD and LD infection were 11.12 and 11.86 per 1000 device days respectively. The average infection rates for VP and LP shunts were 6% and 5.2% per procedure, respectively. The commonest etiological agent causing CSF diversion catheter-related infection (CDRI) was Klebsiella pneumoniae (n = 14, 40%). The risk factors which were independently associated with increased infection risk by cox regression analysis were drain insertion ≥7 days [HR:11.73, p -0.03], posterior approach of EVD insertion (occipital) [HR:9.53, p - 0.01], pre-OP ASA score>3 [HR:8.28, p - 0.013] presence of EVD/LD leak [HR: 17.24, p < 0.0001], male gender [HR:2.05, p-0.05] and presence of associated peri-operative scalp infections [HR:3.531, p-0.005]. Shift to narrow spectrum surgical prophylactic antibiotic [Coefficient: -1.284, p-0.03] and reduction in CSF sampling frequency [Coefficient: -1.741, p-0.02] were found to be negatively associated with CDRI. CONCLUSIONS: The study demonstrated drain insertion ≥7 days, posterior approach of EVD insertion, presence of EVD/LD leak, male gender and presence of associated peri-operative scalp skin and soft tissue infections were associated with increased risk of infection.


Subject(s)
Catheter-Related Infections , Humans , Male , Female , Prospective Studies , Middle Aged , Adult , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Risk Factors , Young Adult , Aged , Adolescent , Cerebrospinal Fluid Shunts/adverse effects , Child , Aged, 80 and over
15.
Antimicrob Resist Infect Control ; 13(1): 15, 2024 02 05.
Article in English | MEDLINE | ID: mdl-38317207

ABSTRACT

BACKGROUND: Continuous surveillance for healthcare-associated infections such as central venous catheter-related bloodstream infections (CVC-BSI) is crucial for prevention. However, traditional surveillance methods are resource-intensive and prone to bias. This study aimed to develop and validate fully-automated surveillance algorithms for CVC-BSI. METHODS: Two algorithms were developed using electronic health record data from 1000 admissions with a positive blood culture (BCx) at Karolinska University Hospital from 2017: (1) Combining microbiological findings in BCx and CVC cultures with BSI symptoms; (2) Only using microbiological findings. These algorithms were validated in 5170 potential CVC-BSI-episodes from all admissions in 2018-2019, and results extrapolated to all potential CVC-BSI-episodes within this period (n = 181,354). The reference standard was manual record review according to ECDC's definition of microbiologically confirmed CVC-BSI (CRI3-CVC). RESULTS: In the potential CVC-BSI-episodes, 51 fulfilled ECDC's definition and the algorithms identified 47 and 49 episodes as CVC-BSI, respectively. Both algorithms performed well in assessing CVC-BSI. Overall, algorithm 2 performed slightly better with in the total period a sensitivity of 0.880 (95%-CI 0.783-0.959), specificity of 1.000 (95%-CI 0.999-1.000), PPV of 0.918 (95%-CI 0.833-0.981) and NPV of 1.000 (95%-CI 0.999-1.000). Incidence according to the reference and algorithm 2 was 0.33 and 0.31 per 1000 in-patient hospital-days, respectively. CONCLUSIONS: Both fully-automated surveillance algorithms for CVC-BSI performed well and could effectively replace manual surveillance. The simpler algorithm, using only microbiology data, is suitable when BCx testing adheres to recommendations, otherwise the algorithm using symptom data might be required. Further validation in other settings is necessary to assess the algorithms' generalisability.


Subject(s)
Catheter-Related Infections , Central Venous Catheters , Cross Infection , Sepsis , Humans , Central Venous Catheters/adverse effects , Catheter-Related Infections/diagnosis , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Cross Infection/epidemiology , Hospitalization , Sepsis/microbiology
16.
J Infect Chemother ; 30(7): 664-667, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38184108

ABSTRACT

Catheter-related bloodstream infections (CRBSIs) caused by Lactobacillus spp. and Lacticaseibacillus spp. are rare, and their clinical course and optimal treatment remain uncertain. In this report, we present a 46-year-old male patient who experienced clinically diagnosed Lacticaseibacillus paracasei CRBSI on four separate occasions, despite receiving systemic administration of antibiotics and antimicrobial lock therapy. The patient did not develop L. paracasei bacteremia after catheter removal. This case report furthers our knowledge of CRBSI caused by Lactobacillus and related genera and highlights the need for further research.


Subject(s)
Anti-Bacterial Agents , Bacteremia , Catheter-Related Infections , Lacticaseibacillus paracasei , Humans , Male , Middle Aged , Catheter-Related Infections/microbiology , Catheter-Related Infections/drug therapy , Catheter-Related Infections/diagnosis , Bacteremia/microbiology , Bacteremia/drug therapy , Bacteremia/diagnosis , Anti-Bacterial Agents/therapeutic use , Lacticaseibacillus paracasei/isolation & purification
17.
Nat Commun ; 15(1): 61, 2024 01 02.
Article in English | MEDLINE | ID: mdl-38168042

ABSTRACT

Catheter-associated urinary tract infections (CAUTIs), a common cause of healthcare-associated infections, are caused by a diverse array of pathogens that are increasingly becoming antibiotic resistant. We analyze the microbial occurrences in catheter and urine samples from 55 human long-term catheterized patients collected over one year. Although most of these patients were prescribed antibiotics over several collection periods, their catheter samples remain colonized by one or more bacterial species. Examination of a total of 366 catheter and urine samples identify 13 positive and 13 negative genus co-occurrences over 12 collection periods, representing associations that occur more or less frequently than expected by chance. We find that for many patients, the microbial species composition between collection periods is similar. In a subset of patients, we find that the most frequently sampled bacteria, Escherichia coli and Enterococcus faecalis, co-localize on catheter samples. Further, co-culture of paired isolates recovered from the same patients reveals that E. coli significantly augments E. faecalis growth in an artificial urine medium, where E. faecalis monoculture grows poorly. These findings suggest novel strategies to collapse polymicrobial CAUTI in long-term catheterized patients by targeting mechanisms that promote positive co-associations.


Subject(s)
Catheter-Related Infections , Urinary Tract Infections , Humans , Escherichia coli , Catheter-Related Infections/microbiology , Catheters , Urinary Tract Infections/microbiology , Enterococcus faecalis , Bacteria
18.
Pediatr Nephrol ; 39(7): 2171-2175, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38267590

ABSTRACT

BACKGROUND: Bloodstream infections (BSIs) are a leading cause of hospitalizations and mortality among patients receiving hemodialysis (HD) therapy, especially those with a central venous catheter (CVC) for dialysis access. The use of chlorhexidine impregnated catheter caps (ClearGuard) has been associated with a decrease in the rate of HD catheter-related BSIs (CA-BSIs) in adults; similar data have not been published for children. METHODS: We compared CA-BSI data from participating centers within the Standardizing Care to Improve Outcomes in Pediatric Endstage Kidney Disease (SCOPE) collaborative based on the center's use of ClearGuard caps for patients with HD catheter access. Centers were characterized as ClearGuard (CG) or non-ClearGuard (NCG) centers, with CA-BSI data pre- and post-CG implementation reviewed. All positive blood cultures in participating centers were reported to the SCOPE collaborative and adjudicated by an infectious disease physician. RESULTS: Data were available from 1786 SCOPE enrollment forms completed January 2016-January 2022. January 2020 served as the implementation date for analyzing CG versus NCG center data, with this being the time when the last CG center underwent implementation. Post January 2020, there was a greater decrease in the rate of HD CA-BSI in CG centers versus NCG centers, with a decrease from 1.18 to 0.23 and 0.41 episodes per 100 patient months for the CG and NCG centers, respectively (p = 0.002). CONCLUSIONS: Routine use of ClearGuard caps in pediatric dialysis centers was associated with a reduction of HD CA-BSI rates in pediatric HD patients.


Subject(s)
Catheter-Related Infections , Central Venous Catheters , Chlorhexidine , Kidney Failure, Chronic , Renal Dialysis , Humans , Renal Dialysis/adverse effects , Renal Dialysis/methods , Child , Catheter-Related Infections/microbiology , Catheter-Related Infections/epidemiology , Catheter-Related Infections/etiology , Male , Female , Adolescent , Central Venous Catheters/adverse effects , Central Venous Catheters/microbiology , Kidney Failure, Chronic/therapy , Chlorhexidine/therapeutic use , Chlorhexidine/analogs & derivatives , Chlorhexidine/administration & dosage , Child, Preschool , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Anti-Infective Agents, Local/administration & dosage , Anti-Infective Agents, Local/therapeutic use
19.
Crit Rev Microbiol ; 50(2): 168-195, 2024 Mar.
Article in English | MEDLINE | ID: mdl-36651058

ABSTRACT

Present-day healthcare employs several types of invasive devices, including urinary catheters, to improve medical wellness, the clinical outcome of disease, and the quality of patient life. Among urinary catheters, the Foley catheter is most commonly used in patients for bladder drainage and collection of urine. Although such devices are very useful for patients who cannot empty their bladder for various reasons, they also expose patients to catheter-associated urinary tract infections (CAUTIs). Catheter provides an ideal surface for bacterial colonization and biofilm formation, resulting in persistent bacterial infection and severe complications. Hence, rigorous efforts have been made to develop catheters that harbour antimicrobial and anti-fouling properties to resist colonization by bacterial pathogens. In this regard, catheter modification by surface functionalization, impregnation, blending, or coating with antibiotics, bioactive compounds, and nanoformulations have proved to be effective in controlling biofilm formation. This review attempts to illustrate the complications associated with indwelling Foley catheters, primarily focussing on challenges in fighting CAUTI, catheter colonization, and biofilm formation. In this review, we also collate scientific literature on catheter modification using antibiotics, plant bioactive components, bacteriophages, nanoparticles, and studies demonstrating their efficacy through in vitro and in vivo testing.


Subject(s)
Catheter-Related Infections , Urinary Tract Infections , Humans , Catheter-Related Infections/etiology , Catheter-Related Infections/microbiology , Urinary Tract Infections/prevention & control , Urinary Catheters/adverse effects , Urinary Catheters/microbiology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Biofilms , Bacteria
20.
Am J Infect Control ; 52(2): 195-199, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37295676

ABSTRACT

BACKGROUND: Hospital acquired infections (HAIs) are a major driver of morbidity and cost in health systems. Central line-associated bloodstream infections (CLABSIs) require intensive surveillance and review. All-cause hospital-onset bacteremia (HOB) may be a simpler reporting metric, correlates with CLABSI, and is viewed positively by HAI experts. Despite the ease in the collection, the proportion of HOBs that are actionable and preventable is unknown. Moreover, quality improvement strategies targeting it may be more challenging. In this study, we describe the bedside provider-perceived sources of HOB in order to provide insight into this new metric as a target for HAI prevention. METHODS: All cases of HOBs in 2019 from an academic tertiary care hospital were retrospectively reviewed. Information was collected to assess provider-perceived etiology and associated clinical factors (microbiology, severity, mortality, and management). HOB was categorized as preventable or not preventable based on the perceived source from the care team and management decisions. Preventable causes included device-associated bacteremias, pneumonias, surgical complications, and contaminated blood cultures. RESULTS: Of the 392 instances of HOB, 56.0% (n = 220) had episodes that were determined not preventable by providers. Excluding blood culture contaminates, the most common cause of preventable HOB was secondary to CLABSIs (9.9%, n = 39). Of the HOBs that were not preventable, the most common sources were gastrointestinal and abdominal (n = 62), neutropenic translocation (n = 37), and endocarditis (n = 23). Patients with HOB were generally medically complex with an average Charlson comorbidity index of 4.97. This translated into a higher average length of stay (29.23 vs 7.56, P < .001) and higher inpatient mortality (odds ratio 8.3, confidence interval [6.32-10.77]) when compared to admissions without HOB. CONCLUSIONS: The majority of HOBs were not preventable and the HOB metric may be a marker of a sicker patient population making it a less actionable target for quality improvement. Standardization across the patient mix is important if the metric becomes linked to reimbursement. If the HOB metric were to be used in lieu of CLABSI, large tertiary care health systems that house sicker patients may be unfairly financially penalized for caring for more medically complex patients.


Subject(s)
Bacteremia , Catheter-Related Infections , Cross Infection , Humans , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Retrospective Studies , Harm Reduction , Cross Infection/epidemiology , Cross Infection/prevention & control , Cross Infection/complications , Bacteremia/epidemiology , Bacteremia/etiology , Hospitals
SELECTION OF CITATIONS
SEARCH DETAIL
...