J Radiol Prot ; 23(3): 327-36, 2003 Sep.
Article in English | MEDLINE | ID: mdl-14582723

ABSTRACT

This study was intended to evaluate radiation risk to patients during cerebral interventions and the contribution to this risk from work practices. Thirty nine patients undergoing cerebral interventions in a digital subtraction angiography suite were included in this study. Patients who underwent cerebral interventions were categorised into two groups according to the number of cerebral interventions performed on them, and their effective doses were calculated. The effective dose for patients undergoing a single cerebral intervention (group A) varied from 1.55 to 15.9 mSv and for multiple cerebral interventions (group B) varied from 16.52 to 43.52 mSv. Two patients who underwent multiple cerebral interventions (group B) had alopecia of the irradiated scalp.


Subject(s)
Angiography, Digital Subtraction/radiation effects , Cerebral Angiography/radiation effects , Radiation Dosage , Brain/diagnostic imaging , Female , Fluoroscopy , Humans , Male , Radiation Monitoring , Radiometry , Radionuclide Imaging , Risk Assessment