1.
Comb Chem High Throughput Screen ; 23(10): 1090-1099, 2020.
Article in English | MEDLINE | ID: mdl-32691707

ABSTRACT

BACKGROUND: Allergic rhinitis, acute nasal congestion and sinusitis are one of the most common health problems and have a major effect on the quality of life. Several medications are used to improve the symptoms of such diseases in humans. Pharmaceutical pomade form containing Ephedrine (EPD) HCl, Naphazoline (NPZ) HCl, Antazoline (ANT) HCl, and Chlorobutanol (CLO) is one of them. OBJECTIVE: For these reasons, this study includes the development of spectrophotometric and chromatographic methods for the determination of EPD HCl, NPZ HCl, ANT HCl, and CLO active agents in the pharmaceutical pomade. METHOD: In the spectrophotometric method, third-order derivative of the amplitudes at 218 nm n=5 and the first-order derivative of the amplitudes 254 nm n=13 was selected for the determination of EPD, ANT, respectively while NPZ was determined by the second derivative at 234 nm and n=21. Colorimetric detection was applied for assay analysis of CLO at 540 nm. Furthermore, a reverse phase high performance liquid chromatographic (RP- HPLC) method has been developed and optimized by using Agilent Zorbax Eclipse XDB C18 (75 mm x 3.0 mm, 3.5µm) column. The column temperature was 40°C, binary gradient elution was used and the mobile phase consisted of 15 mM phosphate buffer in distilled water (pH 3.0) and methanol, and the flow rate was 0.6 mL min-1 and the UV detector was detected at 210 nm. The linear operating range was obtained as 11.97-70, 0.59-3, 2.79-30, and 2.92-200 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO respectively. RESULTS: The LOD values were found to be 3.95, 0.19, 0.92 and 0.96 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO in the spectrophotometric method, respectively. The linear ranges in the RP-HPLC method were 8.2-24.36 µg mL-1, 0.083 - 0.75 µg/mL, 2.01-7.5 µg mL-1 and 2.89-24.4 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO, respectively. The LOD values in the validation studies were 2.7, 0.025, 0.66 and 0.86 µg mL-1 for EPD HCl, NPZ HCl, ANT HCl, and CLO in RP-HPLC method respectively. CONCLUSION: The results of the spectrophotometric and chromatographic methods were compared and no differences were found between the two methods.


Subject(s)
Antazoline/analysis , Chlorobutanol/analysis , Ephedrine/analysis , Naphazoline/analysis , Chromatography, High Pressure Liquid/instrumentation , Equipment Design , Molecular Structure
2.
Chem Pharm Bull (Tokyo) ; 62(4): 395-8, 2014.
Article in English | MEDLINE | ID: mdl-24695350

ABSTRACT

The analysis of genotoxic impurities (GTIs) in active pharmaceutical ingredients (APIs) is a challenging task. The target detection limit (DL) in an API is typically around 1 ppm (1 µg/g API). Therefore, a sensitive and selective analytical method is required for their analysis. 4-Chloro-1-butanol, an alkylating agent, is one of the GTIs. It is generated when tetrahydrofuran and hydrochloric acid are used during the synthesis of the APIs. In this study, a sensitive and robust gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the identification of 4-chloro-1-butanol in APIs. In the GC-MS method, 3-chloro-1-butanol was employed as an internal standard to ensure accuracy and precision. Linearity was observed over the range 0.08 to 40 ppm (µg/g API), with a R(2) value of 0.9999. The DL and quantitation limit (QL) obtained were 0.05 ppm and 0.08 ppm (0.13 ng/mL and 0.20 ng/mL as the 4-chloro-1-butanol concentration), respectively. These DL and QL values are well over the threshold specified in the guidelines. The accuracy (recovery) of detection ranged from 90.5 to 108.7% between 0.4 ppm and 20 ppm of 4-chloro-1-butanol. The relative standard deviation in the repeatability of the spiked recovery test was 6.0%. These results indicate the validity of the GC-MS method developed in this study. The GC-MS method was applied for the determination of 4-chloro-1-butanol in the API (Compound A), which is under clinical trials. No 4-chloro-1-butanol was found in Compound A (below QL, 0.08 ppm).


Subject(s)
Alkylating Agents/analysis , Chemistry, Pharmaceutical/methods , Chlorobutanol/analogs & derivatives , Gas Chromatography-Mass Spectrometry/methods , Chlorobutanol/analysis , Limit of Detection , Reproducibility of Results , Sensitivity and Specificity
3.
Anal Sci ; 30(3): 377-82, 2014.
Article in English | MEDLINE | ID: mdl-24614733

ABSTRACT

An alkylating agent, 4-chloro-1-butanol, is a genotoxic impurity (GTI); it may be generated during the synthesis of active pharmaceutical ingredients (APIs). For the trace-level detection of GTIs in APIs, usually, gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) is employed. In this study, a novel LC-inductively coupled plasma (ICP)-MS method was developed and validated. Linearity was observed over the 0.5-50 ppm (µg/g API) range, with an R(2) value of 0.9994. The detection limit (DL) and quantitation limit (QL) were 0.2 and 0.5 ppm, respectively. The DL and QL values are well over the thresholds specified in the guidelines. The accuracy was 95.1-114.7% for concentrations of 1-50 ppm, and the relative standard deviation of the spiked recovery test's repeatability was 6.2%. In addition, six lots of an API were analyzed, and all results were lower than the reported threshold (1 ppm).


Subject(s)
Chlorobutanol/analogs & derivatives , Chromatography, High Pressure Liquid/methods , Mass Spectrometry/methods , Pharmaceutical Preparations/chemistry , Chlorobutanol/analysis , Chromatography, High Pressure Liquid/instrumentation , Mass Spectrometry/instrumentation
4.
J Chromatogr Sci ; 47(4): 272-8, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19406012

ABSTRACT

A gas chromatography with flame ionization detection method (GC-FID) with direct injection, using a capillary column, was validated to determine ethanol, acetaldehyde, methanol, and acetone in different human matrices, such as whole blood, vitreous humour, and urine, with clinical and forensic interest. This method was also employed to quantify these compounds in cell culture medium, thus being useful in basic research. A good peak resolution was achieved, with linear correlation between concentration and peak areas for all the compounds in all the matrices. The inter- and intra-day precisions of the method were always under 15% and 10%, respectively. The accuracy of the method, calculated as the percentage of the target concentration, was within the acceptable limits. The obtained limits of detection were below 0.85 mg/L for acetaldehyde and below 0.75 mg/L for the other considered compounds. The small injection volume and the high split ratios applied, allied to the high performance of the GC column, resulted in very good peak resolution and high sensitivities. This method is easy to perform, making it suitable for the routine of clinical biochemistry and forensic laboratories.


Subject(s)
Acetaldehyde/analysis , Body Fluids/chemistry , Chlorobutanol/analysis , Chromatography, Gas/methods , Ethanol/analysis , Methanol/analysis , Cell Culture Techniques , Culture Media/analysis , Humans , Quality Control , Regression Analysis , Sensitivity and Specificity
5.
J Pharm Pharmacol ; 61(4): 533-7, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19298702

ABSTRACT

OBJECTIVES: Alkylating agents are potentially genotoxic impurities that may be present in drug products. These impurities occur in pharmaceuticals as by-products from the synthetic steps involved in drug production, as impurities in starting materials or from in-situ reactions that take place in the final drug product. Currently, analysis for genotoxic impurities is typically carried out using either HPLC/MS or GC/MS. These techniques require specialist expertise, have long analysis times and often use sample clean-up procedures. Reichardt's dye is well known for its solvatochromic properties. In this paper the dye's ability to undergo alkylation is reported. METHODS: The reaction between Reichardt's dye and alkylating agents such as 4-chloro-1-butanol and ethyl methanesulfonate was monitored spectrophotometrically at 618 nm in acetonitrile and 624 nm in N,N-dimethylformamide. KEY FINDINGS: Changes in absorption were observed using low levels of alkylating agent (5-10 parts per million). Alkylation of the dye with 4-chloro-1-butanol and ethyl methanesulfonate was confirmed. Reichardt's dye, and its changing UV absorption, was examined in the presence of paracetamol (10 and 100 mg/ml). Whilst the alkylation-induced changes in UV absorption were not as pronounced as with standard solutions, detection of alkylation was still possible. CONCLUSIONS: Using standard solutions and in the presence of a drug matrix, Reichardt's dye shows promise as a reagent for detection of low levels of industrially important alkylating agents.


Subject(s)
Alkylating Agents/analysis , Drug Contamination , Magnetic Resonance Spectroscopy/methods , Mutagens/analysis , Pyridinium Compounds/chemistry , Chemistry, Pharmaceutical , Chlorobutanol/analogs & derivatives , Chlorobutanol/analysis , Chromogenic Compounds/chemistry , Diazonium Compounds/analysis , Ethyl Methanesulfonate/analysis , Hydrocarbons, Brominated/analysis , In Vitro Techniques
6.
J Pharm Biomed Anal ; 43(1): 179-85, 2007 Jan 04.
Article in English | MEDLINE | ID: mdl-16920323

ABSTRACT

A single stability-indicating assay for oxytocin (OT) in pharmaceutical dosage forms using gradient elution over 21 min has been reported in the literature. Furthermore, published and compendial methods for the analysis of OT containing dosage forms also involve using HPLC with gradient elution and complicated mobile phases that include hydrophobic ion pairing agents. A simple isocratic and stability-indicating assay was developed and validated. The conditions are as follows, column: Phenomenex C18 Hypersil, 5 microm packing, 4.6 mm x 150 mm with acetonitrile-phosphate buffer (pH 5; 0.08 M) (20:80) as the mobile phase with UV detection at 220 nm The method was found to be specific for OT in the presence of degradation products and chlorbutol (preservative) with an overall analytical run time of 16 min. Accuracy was determined to be 0.77-1.18% bias for all samples tested. Intra-assay precision (repeatability) was found to be 0.22-1.04%R.S.D. while the inter-day precision (intermediate precision) was found to be 1.27-1.68%R.S.D. for the samples studied. The calibration curve was found to be linear with the equation y = 1.81x + 0.02 and a linear regression coefficient of 0.9991 over the range 0.4-12.0 IU/ml. The LOD and the LOQ were determined to be 0.1 and 0.4 IU/ml, respectively. Syntocinon, a commercially available dosage form of OT was assayed resulting in 100.5-106.6% recovery of the label claim and an average of 10.04 IU/ml.


Subject(s)
Oxytocin/analysis , Buffers , Calibration , Chlorobutanol/analysis , Chromatography, High Pressure Liquid , Dosage Forms , Drug Stability , Indicators and Reagents , Oxidation-Reduction , Photochemistry , Reference Standards , Reproducibility of Results , Temperature
8.
J Sep Sci ; 28(2): 137-43, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15754820

ABSTRACT

Preservatives are used to protect pharmaceutical formulations from microbial attack during the period of administration to the patient. Because of their biological activity, preservatives have to be identified and assayed according to the same rules as apply to active components. A number of methods for separation of preservatives are reported, to account for the heterogeneity of their chemical structures. A capillary electrophoretic method was devised for simple and simultaneous qualification and quantification of the preservatives most often included in pharmaceuticals, such as benzyl alcohol, parabens, phenol, m-cresol, chlorobutanol, thimerosal. After systematic method development, the electrophoretic conditions were defined as: 50 mM borate buffer pH 9.0 containing 20 mM SDS. Separations were performed at a temperature of 20 degrees C and with detection at 214 nm. Preservatives under examination can be analyzed within a 10 min run. The method was successfully validated and applied to the determination of preservatives in a number of pharmaceuticals. Results from the CE method were compared with those from reference methods.


Subject(s)
Chromatography, Micellar Electrokinetic Capillary/instrumentation , Chromatography, Micellar Electrokinetic Capillary/methods , Electrophoresis, Capillary/methods , Pharmaceutical Preparations/analysis , Preservatives, Pharmaceutical/analysis , Benzyl Alcohol/analysis , Chlorobutanol/analysis , Cresols/analysis , Hydrogen-Ion Concentration , Parabens/analysis , Phenol/analysis , Reproducibility of Results , Sodium Dodecyl Sulfate/pharmacology , Temperature , Thimerosal/analysis , Time Factors
9.
J Chromatogr B Biomed Appl ; 673(1): 59-66, 1995 Nov 03.
Article in English | MEDLINE | ID: mdl-8925075

ABSTRACT

A sensitive and specific method for the determination of chlorobutanol (1,1,1-trichloro-2-methyl-2-propanol) in mouse serum, urine, and embryos by capillary gas chromatography with electron capture detection is described. For sample preparation n-hexane was used to extract chlorobutanol and the internal standard 2,2,2-trichloroethanol (TCE) from each matrix. Following extraction chromatographic separation of the samples was achieved with a fused-silica capillary column (30 m x 0.25 mm I.D., 0.25 micron film thickness). The method as described has the required sensitivity to quantitate chlorobutanol in individual embryos following administration of a single oral dose of the drug to a pregnant mouse. The limit of detection was 1 pg on column and the detector response was linear from 1 to 100 micrograms/ml for serum, 0.2 to 20 micrograms/ml for urine, and 1 to 10 ng/embryo.


Subject(s)
Chlorobutanol/analysis , Chromatography, Gas/methods , Embryo, Mammalian/chemistry , Animals , Chlorobutanol/blood , Chlorobutanol/pharmacokinetics , Chlorobutanol/urine , Ethylene Chlorohydrin/analogs & derivatives , Ethylene Chlorohydrin/analysis , Female , Mice , Mice, Inbred Strains , Pregnancy , Sensitivity and Specificity
10.
Z Lebensm Unters Forsch ; 178(6): 465-7, 1984 Jun.
Article in English | MEDLINE | ID: mdl-6485552

ABSTRACT

A rapid method for the determination of chlorobutanol(1,1,1-trichloro-2-methylpropan-2-ol) in milk is described. The method is based on a steam-distillation solvent-extraction technique and a quantitative determination of chlorobutanol by gas chromatography using a glass-capillary column coated with Carbowax 20M and 2,2,2-trichloroethanol as internal standard. The detection limit is 1 pg and recoveries of chlorobutanol are between 93 und 99%. Fifty-two milk samples have been analysed.


Subject(s)
Chlorobutanol/analysis , Milk/analysis , Animals , Cattle , Chromatography, Gas/methods
11.
J Clin Hosp Pharm ; 9(1): 29-39, 1984 Mar.
Article in English | MEDLINE | ID: mdl-6715560

ABSTRACT

The disappearance of chlorbutol from aqueous solutions stored in polyethylene containers under various experimental and simulated patient use conditions is described. Chlorbutol is lost by sorption into the container wall, container insert and by permeation into the external environment. The extent of chlorbutol loss from solution and uptake by the container components is dependent on temperature, chlorbutol concentration and the closure used. Aqueous chlorbutol solutions stored in the polyethylene container evaluated have a predicted shelf-life (time for 10% loss) of about 4 months at 25 degrees C and 8 months at 20 degrees C. Negligible loss is found during simulated patient use over 1 month.


Subject(s)
Chlorobutanol/analysis , Chromatography, Gas , Drug Packaging , Drug Stability , Drug Storage , Ophthalmic Solutions/analysis , Polyethylenes , Temperature
12.
J Pharm Sci ; 72(3): 277-80, 1983 Mar.
Article in English | MEDLINE | ID: mdl-6842379

ABSTRACT

A reverse-phase high-performance liquid chromatographic assay for chlorobutanol was developed and found suitable for the routine analysis of ophthalmic ointments and aqueous solutions. The method utilized a column packed with 10-microns octadecylsilane with a mobile phase of methanol-water (50:50). Peak detection was by UV absorption at 210 nm. In this chromatographic system, chlorobutanol had a capacity factor (K') of 4.1. Standard curves obtained in the presence of ointment vehicle containing an aminoglycoside were linear, intercepted at zero, and averaged 99.4% recovery. Degradation studies indicated that the method was stability indicating. The analytical results for a complete experimental ophthalmic ointment and an aqueous ophthalmic diluent are presented. This high-performance liquid chromatographic method of analysis represents an alternative to GC procedures for determining chlorobutanol.


Subject(s)
Chlorobutanol/analysis , Chromatography, Gas/methods , Chromatography, High Pressure Liquid/methods , Ointments/analysis , Ophthalmic Solutions/analysis , Spectrophotometry, Ultraviolet/methods
18.
Am J Hosp Pharm ; 26(1): 53, 1969 Jan.
Article in English | MEDLINE | ID: mdl-5763891
SELECTION OF CITATIONS