Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.004
Filter
1.
Biomolecules ; 14(5)2024 May 09.
Article in English | MEDLINE | ID: mdl-38785972

ABSTRACT

Background: Erectile dysfunction (ED) stands out as one of the most prevalent sexual disorders in men, with its incidence progressively escalating with age. As delineated by the International Consultation Committee for Sexual Medicine on Definitions/Epidemiology/Risk Factors for Sexual Dysfunction, the prevalence of ED among men under 40 years is estimated to be within the range of 1-10%. The aim of this study was to determine the relationship between the concentration of bioelements (Zn, Cu, Fe, Cr, Mg, and Mn) in the serum and bone tissue and the concentration of selected hormones in men with and without erectile dysfunction. Materials and methods: The retrospective cohort study included 152 men who underwent total hip arthroplasty for hip osteoarthritis at the Department of Orthopaedic Traumatology and Musculoskeletal Oncology at the Pomeranian Medical University in Szczecin. Certain exclusion criteria were applied to ensure the integrity of the study. These included individuals with diabetes, a history of cancer, alcohol abuse, liver or kidney failure, New York Heart Association (NYHA) class III or IV heart failure, and those taking medications that affect bone metabolism, such as mineral supplements, neuroleptics, chemotherapeutic agents, immunosuppressants, corticosteroids, or antidepressants. Patients with hypogonadism or infertility were excluded from the study. Results: The study showed an association between bioT concentrations and Cu concentrations in both patients with and without erectile dysfunction. A correlation between bioactive testosterone and Cr concentrations was also observed in both groups. Patients with erectile dysfunction showed a relationship between bioT concentration and Zn concentration, TT concentration and Mn concentration, FT concentration and Zn concentration, and E2 concentration and Cr concentration. An analysis of elemental concentrations in bone tissue showed an association between FT and Mg and Mn concentrations, but only in patients with erectile dysfunction. In patients without erectile dysfunction, a correlation was observed between FT and Cu concentrations. A correlation was also observed between bioT concentrations and Mg, Mn, and Zn concentrations, but only in patients with erectile dysfunction. In patients without erectile dysfunction, a correlation was observed between bioT and Cu concentrations. Conclusions: Studying the relationship between the concentration of bioelements (Zn, Cu, Fe, Cr, Mg, and Mn) in the serum and bone tissue and the concentration of selected hormones in men may be important in explaining the etiology of the problem. The study of the concentration of Zn and Cu in bone tissue and serum showed that these two elements, regardless of the place of accumulation, may be related to the concentration of androgens in men.


Subject(s)
Arthroplasty, Replacement, Hip , Bone and Bones , Copper , Erectile Dysfunction , Zinc , Humans , Male , Erectile Dysfunction/blood , Middle Aged , Aged , Retrospective Studies , Zinc/blood , Bone and Bones/metabolism , Copper/blood , Aging/blood , Chromium/blood , Magnesium/blood , Iron/blood , Iron/metabolism , Manganese/blood , Manganese/analysis , Trace Elements/blood , Testosterone/blood , Adult
2.
J Environ Sci (China) ; 143: 224-234, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38644019

ABSTRACT

Hexavalent chromium and its compounds are prevalent pollutants, especially in the work environment, pose a significant risk for multisystem toxicity and cancers. While it is known that chromium accumulation in the liver can cause damage, the dose-response relationship between blood chromium (Cr) and liver injury, as well as the possible potential toxic mechanisms involved, remains poorly understood. To address this, we conducted a follow-up study of 590 visits from 305 participants to investigate the associations of blood Cr with biomarkers for liver injury, including serum alanine aminotransferase (ALT), aspartate aminotransferase (AST), total bilirubin (TBIL), and direct bilirubin (DBIL), and to evaluate the mediating effects of systemic inflammation. Platelet (PLT) and the platelet-to-lymphocyte ratio (PLR) were utilized as biomarkers of systemic inflammation. In the linear mixed-effects analyses, each 1-unit increase in blood Cr level was associated with estimated effect percentage increases of 0.82% (0.11%, 1.53%) in TBIL, 1.67% (0.06%, 3.28%) in DBIL, 0.73% (0.04%, 1.43%) in ALT and 2.08% (0.29%, 3.87%) in AST, respectively. Furthermore, PLT mediated 10.04%, 11.35%, and 10.77% increases in TBIL, DBIL, and ALT levels induced by chromate, respectively. In addition, PLR mediated 8.26% and 15.58% of the association between blood Cr and TBIL or ALT. These findings shed light on the mechanisms underlying blood Cr-induced liver injury, which is partly due to worsening systemic inflammation.


Subject(s)
Chromates , Chromium , Inflammation , Humans , Chromium/toxicity , Chromium/blood , Inflammation/blood , Male , Chromates/toxicity , Chromates/blood , Adult , Female , Middle Aged , Biomarkers/blood , Occupational Exposure/adverse effects , Alanine Transaminase/blood , Chemical and Drug Induced Liver Injury/blood , Aspartate Aminotransferases/blood , Environmental Pollutants/blood , Environmental Pollutants/toxicity
3.
J Trace Elem Med Biol ; 84: 127425, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38484635

ABSTRACT

BACKGROUND AND AIM: Diabetic kidney disease (DKD) is the primary cause of chronic kidney disease (CKD) worldwide. Altered mineral levels leading to adverse outcomes are widely reported in diabetes but limited in DKD, in the Indian scenario, hence this study was taken up to address this issue. METHODS: A hospital-based case-control study was taken up with 54 healthy controls (C) and 140 subjects with type 2 diabetes wherein 74 subjects with diabetes and CKD formed the DKD group, and 66 subjects with diabetes but no CKD formed the diabetic no-chronic kidney disease (DNCKD) group. High-resolution inductively coupled plasma mass spectrometry was used to evaluate the blood levels of minerals (calcium (Ca), vanadium (V), chromium (Cr), manganese (Mn), iron (Fe), cobalt (Co), copper (Cu), zinc (Zn), and selenium (Se)), and a raw food-based food frequency questionnaire for dietary intakes. Estimated glomerular filtration rate (eGFR) was calculated using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation (mL/min/1.73 m2) and albuminuria. Spearman's rank correlation was used to evaluate the relationship between the categorical variables. RESULTS: The median values of plasma Ca in the DKD group were significantly lower compared with the DNCKD and C groups (10.5 mg/dL vs. 11.0 mg/dL and 11.7 mg/dL, p<0.001). Furthermore, plasma Ca levels lowered with declining kidney function, as evidenced by the eGFR and albuminuria segregation. Dietary intake of minerals did not correlate with the corresponding plasma levels. However, in the DKD group, eGFR correlated positively with the plasma levels of Ca (r= 0.422, p=0.001), Cr (r= 0.351, p=0.008), Mn (r= 0.338, p=0.011), Fe (r= 0.403, p=0.002), Cu (r= 0.274, p=0.041) and negatively with Se (r= -0.486, p<0.001). CONCLUSION: Plasma Ca levels are lower in the DKD group with a strong positive association with eGFR, indicating its role in predicting the onset and progression of kidney function decline.


Subject(s)
Diabetes Mellitus, Type 2 , Minerals , Renal Insufficiency, Chronic , Humans , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/complications , Case-Control Studies , Male , Female , Renal Insufficiency, Chronic/blood , Middle Aged , Minerals/blood , Chromium/blood , Selenium/blood , Aged , Calcium/blood , Glomerular Filtration Rate
4.
J Orthop Res ; 42(6): 1292-1302, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38235918

ABSTRACT

Production of metal debris from implant wear and corrosion processes is now a well understood occurrence following hip arthroplasty. Evidence has shown that metal ions can enter the bloodstream and travel to distant organs including the brain, and in extreme cases, can induce sensorial and neurological diseases. Our objective was tosimultaneously analyze brain anatomy and physiology in patients with long-term and well-functioning implants. Included were subjects who had received total hip or hip resurfacing arthroplastywith an implantation time of a minimum of 7 years (n = 28) and age- and sex-matched controls (n = 32). Blood samples were obtained to measure ion concentrations of cobalt and chromium, and the Montreal Cognitive Assessment was performed. 3T MRI brain scans were completed with an MPRAGE sequence for ROI segmentation and multiecho gradient echo sequences to generate QSM and R2* maps. Mean QSM and R2* values were recorded for five deep brain and four middle and cortical brain structures on both hemispheres: pallidum, putamen, caudate, amygdala, hippocampus, anterior cingulate, inferior temporal, and cerebellum. No differences in QSM or R2* or cognition scores were found between both groups (p > 0.6654). No correlation was found between susceptibility and blood ion levels for cobalt or chromium in any region of the brain. No correlation was found between blood ion levels and cognition scores. Clinical significance: Results suggest that metal ions released by long-term and well-functioning implants do not affect brain integrity.


Subject(s)
Arthroplasty, Replacement, Hip , Brain , Chromium , Cobalt , Hip Prosthesis , Magnetic Resonance Imaging , Humans , Male , Female , Middle Aged , Brain/diagnostic imaging , Aged , Chromium/blood , Cobalt/blood , Adult , Case-Control Studies
5.
BMC Geriatr ; 23(1): 72, 2023 02 03.
Article in English | MEDLINE | ID: mdl-36737686

ABSTRACT

BACKGROUND: Chromium (Cr) and cobalt (Co) are the essential elements for producing metal implants, but might have potential health issues. The research on the correlation between metal implants and blood Cr and Co on a large population is still limited. METHODS: National Health and Nutrition Examination Survey (NHANES) is a program of studies designed to assess the health status of Americans began in the early 1960s. The study was based on the NHANES database from two data collection years (2015-2016 and 2017-2018). The exposure variable of this study was whether the participants had metal objects in the body or not. The outcome variables were blood concentrations of Cr and Co. Age, body mass index, sex, race/ethnicity, income to poverty ratio, tap water behavior, shellfish/fish/tuna/salmon eating habits, level of education, smoking behavior, marital status, blood hemoglobin, and data collection years were included as confounding variables. RESULTS: A total of 4412 participants, aged 40 years or older, were included in this analysis, consisting of the without metal objects group (n = 3150) and the metal objects group (n = 1262). Metal objects was positively correlated to the accumulation of blood Cr (ß = 0.072, 95% CI: 0.043-0.102, p < 0.001) and blood Co (ß = 0.079, 95% CI: 0.049-0.109, p < 0.001). However, the positive correlation of metal objects with blood Cr was only presented in women (ß = 0.112, 95% CI: 0.074-0.151, p < 0.001), but not in men. Meanwhile, the positive relationship between metal objects and blood Cr/Co was not observed in the Asian subgroup. CONCLUSIONS: Blood Cr and Co concentrations were statistically higher in people with metal objects, but with race and sex differences. LEVEL OF EVIDENCE: Level IV, cross-sectional study.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Female , Humans , Male , Chromium/blood , Cobalt/blood , Cross-Sectional Studies , Metals , Nutrition Surveys , Adult
6.
Rev Med Chil ; 151(4): 420-427, 2023 Apr.
Article in English | MEDLINE | ID: mdl-38687516

ABSTRACT

BACKGROUND: Bioaccumulation of toxic metals in the population is associated with adverse health effects. Although some elements are essential for humans, high levels of exposure can be dangerous. OBJECTIVE: To describe the levels of Inorganic Arsenic (AsIn), Cadmium (Cd), Chromium (Cr), and Mercury (Hg) in urine, and Lead (Pb) in blood in the population of Arica, Chile. METHODOLOGY: Descriptive study. Beneficiaries of the Health Surveillance Program of Law 20.590 in sites of higher risk of exposure in the commune of Arica were considered eligible. The results of biological samples to measure their concentrations of AsIn, Cd, Cr, Hg in urine, and Pb in blood between August 2016 and May 2021 are described. RESULTS: 9520 samples from a population with a mean age of 40.5 years were studied. 4.21% of the adult population and 6.57% of the children had AsIn values above 35 µg/L, while at least 95 % of the total samples had levels below 33 µg/L. At least 90 % of the samples had Cd levels below 1.1 µg/L, and 8.44 % had Cd levels above 2 µg/L, higher in males (11.67%). There were no values above the reference in children. 99.77% and 99.33% had Cr and Pb values below the reference limit, respectively (using the lowest reference range established by Chile Ministry of Health (MINSAL) < 5 µg/L). Children did not present risk values for Cr, and 0.16% presented Pb concentrations between 5-10 µg/dL. All samples presented Hg concentrations below risk levels (< 10 µg/L). CONCLUSIONS: The results of this study suggest that a small percentage of the samples analyzed in the beneficiary population of Arica register metal concentration levels above national reference levels established by MINSAL, mainly AsIn, Cd, and Pb. It is essential to continue biomonitoring to reduce and prevent exposure to these metals, which can have harmful effects on human health.


Subject(s)
Cadmium , Environmental Exposure , Lead , Mercury , Humans , Chile , Male , Adult , Female , Child , Lead/blood , Lead/analysis , Environmental Exposure/analysis , Environmental Exposure/adverse effects , Middle Aged , Cadmium/analysis , Cadmium/blood , Cadmium/urine , Adolescent , Young Adult , Mercury/analysis , Mercury/blood , Mercury/urine , Arsenic/analysis , Arsenic/urine , Arsenic/blood , Child, Preschool , Metals, Heavy/analysis , Metals, Heavy/blood , Metals, Heavy/urine , Aged , Chromium/analysis , Chromium/blood , Chromium/urine , Environmental Monitoring , Infant
7.
Bone Joint J ; 104-B(3): 376-385, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35227095

ABSTRACT

AIMS: This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. METHODS: A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life. RESULTS: No differences in mean age (69 years, 40 to 86), mean age adapted Charlson Comorbidity Index (3.1 (SD 1.4)), mean BMI (29.2 kg/m2 (SD 5.8)), or number of other implants were observed between groups. Significant improvements in outcome scores and pain levels were achieved for all groups, and there was no difference in quality of life (12-Item Short-Form Health Survey questionnaire (SF-12)). Mean cobalt and chromium ion levels were significantly higher for the GenuX versus the BPKS hinged TKA (GenuX vs BPKS: cobalt: 16.3 vs 9.4 µg/l; chromium: 9.5 vs 5.2 µg/l). The TiN-coated implants did not appear to confer improvement in the metal ion levels. Metal ion concentrations above 7 µg/l were detected in 81%(29/36) of GenuX patients versus 41% (11/27) in the BPKS group. No GenuX patients had normal levels under 2 µg/l, versus 22% of BPKS patients. No significant reduction in outcome scores was observed regardless of the metal ion levels, whereas higher work-related activity was correlated with higher chromium concentrations. CONCLUSION: Hinged TKA, using MoM hinges, resulted in critically high cobalt and chromium ion concentrations. The BPKS hinged TKA showed significantly lower metal ion concentrations compared with the GenuX TKA. No benefits were observed using TiN coating. The different weightbearing mechanics might influence the wear of the component materials. Higher workloads and physical activity could influence chromium levels. Cite this article: Bone Joint J 2022;104-B(3):376-385.


Subject(s)
Chromium/blood , Cobalt/blood , Knee Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design
8.
PLoS One ; 16(11): e0260065, 2021.
Article in English | MEDLINE | ID: mdl-34793518

ABSTRACT

BACKGROUND: Occupational welding fumes contain varieties of toxic metal particles and may affect cardiovascular system like the Particulate Matters (PM). Few studies have focused on the effects of toxic metals on the hemodynamic balance; however, the reporting results were not consistent. This study aimed to investigate the association between toxic metals exposure (Chromium (Cr), Manganese (Mn) and Lead (Pb)) and blood hemostatic parameters status after a 3-week exposure cessation among workers exposed to welding fumes. METHODOLOGY: Structured interviews and biological samplings were conducted for 86 male workers without a history of Anemia and Cardiovascular diseases (CVDs) and working in a confined space to construct crude oil tanks. Metal levels of Cr, Mn and Pb in urine were measured during the working days using Inductively Coupled Plasma Mass Spectrometer (ICP-MS) method. The concentrations of hemostatic proteins in blood (White blood cell counts (WBC), Lymphocytes, Monocyte, Eosinophil, Neutrophil, Hematocrit (Hct) were assessed after a 3 weeks exposure cessation. Workers were divided into groups based on occupation type (welder group and non-welder group), and based on metal levels (high and low exposure groups) for comparison. Linear regression models were used to explore the association between metal exposure and multiple blood hemostatic parameters adjusted for age, Body Mass Index (BMI), and smoking status. RESULTS: Urine Mn and Cr level of the welder group was significantly higher than the non-welder group (Mn: 0.96 VS 0.22 ug/g creatinine, p < 0.001; Cr: 0.63 VS 0.22 ug/g creatinine, p < 0.01). The mean value of Hct in the welder group was 44.58 ± 2.84 vol%, significantly higher than the non-welder group (43.07 ± 3.31 vol%, p = 0.026). The median value of WBC in the high Mn-exposed group (6.93 ± 1.59 X 106 Cell/ml) was significantly lower than the low Mn-exposed group (7.90 ± 2.13 X 106 Cell/ml, p = 0.018). The linear regression analyses showed that there was a significantly negative association between log transformed WBC value and the Mn exposure groups (high and low) after adjusting for age, BMI, and smoking status (ß = - 0.049, p = 0.045), but no significant result was found between WBC and occupation types (welder and non-welder) (p > 0.05). Multiple linear regression analysis also showed positive association between Hct and occupational types (welder and non-welders) (ß = 0.014, p = 0.055). The other hemostatic parameters were not different from controls when divided by occupation type or metal level groups. CONCLUSIONS: Our results showed that welders were exposed to about 3 to 4 times higher Mn and Cr concentrations than non-welders. Moreover, one third of the non-welders were exposed to high-exposure groups of Mn and Cr metals. Regression models revealed a significant association of the WBC counts with the Mn exposure group. Therefore, we infer that Mn exposure may play a significant role on the blood hemostatic parameters of workers in the confined space. Hazard identification for non-welders should also be conducted in the confined space.


Subject(s)
Gas Poisoning/epidemiology , Metal Workers , Occupational Exposure/statistics & numerical data , Chromium/blood , Chromium/toxicity , Confined Spaces , Eosinophils , Gases/toxicity , Hematocrit , Hemodynamics , Hemostatics/toxicity , Humans , Lead/blood , Lead/toxicity , Leukocyte Count , Manganese/blood , Manganese/toxicity , Monocytes , Neutrophils , Occupational Diseases/epidemiology , Occupational Diseases/etiology , Occupational Exposure/economics , Thailand , Welding
9.
Clin Orthop Relat Res ; 479(12): 2633-2650, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34232144

ABSTRACT

BACKGROUND: The evaluation of the natural history prevalence of adverse local tissue reactions (ALTRs) using MRI has focused only on metal-on-metal (MoM) bearing surfaces without comparison to nonMoM bearing surfaces. QUESTIONS/PURPOSES: To determine (1) the longitudinal changes and differences in blood metal ion levels in patients with hip resurfacing arthroplasty (HRA), ceramic-on-ceramic (CoC) THA, and metal-on-polyethylene (MoP) THA compared with those undergoing ceramic-on-polyethylene (CoP) THA; (2) how the longitudinal change of synovial reaction classification in patients with HRA, CoC THA, and MoP THA compares with those undergoing CoP THA, and whether there is an association between the presence of an ALTR or metallosis on MRI with corresponding patient-reported outcomes, or the presence of capsular dehiscence; and (3) differences in blood metal ion levels between patients undergoing HRA with an ALTR or metallosis on MRI and those with HRA without these conditions. METHODS: Between March 2014 and February 2019, 22,723 patients underwent primary HRA and THA at one center. Patients received an HRA based on their desired athletic level after surgery and the presence of normal acetabular and proximal femoral bone morphology without osteopenia or osteoporosis. Two percent (342 of 22,723) of patients were contacted to participate, and 71% (243 of 342 hips in 206 patients) were enrolled for analysis at baseline. The patients underwent arthroplasty for degenerative joint disease, and 25 patients withdrew over the course of the study. We included patients who were more than 1 year postarthroplasty. All participants had an MRI examination and blood serum ion testing and completed a Hip Disability and Osteoarthritis Outcome Score survey annually for four years (baseline, year 1, year 2, year 3). Morphologic and susceptibility-reduced MR images were evaluated by a single radiologist not involved in the care of patients for the presence and classification of synovitis (Gwet AC1: 0.65 to 0.97), synovial thickness, and volume (coefficient of repeatability: 1.8 cm3). Linear mixed-effects models were used to compare the mean synovial thickness, synovial volume, and Hip Disability and Osteoarthritis Outcome Score subscales between bearing surfaces at each timepoint and within each bearing surface over time. Marginal Cox proportional hazards models were used to compare the time to and the risk of developing ALTR only, metallosis only, and ALTR or metallosis between bearing surfaces. All models were adjusted for age, sex, BMI, and length of implantation based on known confounders for hip arthroplasty. Adjustment for multiple comparisons was performed using the Dunnett-Hsu method. RESULTS: Patients with unilateral HRA had higher cobalt and chromium serum ion levels (baseline: 1.8 ± 0.8 ppb, year 1: 2.0 ± 1.5 ppb, year 2: 2.1 ± 1.2 ppb, year 3: 1.6 ± 0.7 ppb) than those with unilateral CoP bearings (baseline: 0.0 ± 0.1 ppb, year 1: 0.1 ± 0.3 ppb, year 2: 0.0 ± 0.2 ppb, year 3: 0.0 ± 0.0 ppb) at all timepoints (p < 0.001 for each time point). More patients who received an HRA developed ALTR or metallosis on MRI than did patients with CoP bearings (hazard ratio 4.8 [95% confidence interval 1.2 to 18.4]; p = 0.02). There was no association between the longitudinal change of synovial reaction to ALTR or metallosis on MRI with patient-reported outcomes. In addition, there was no association between the presence of dehiscence at baseline and the subsequent development of ALTR or metallosis, as seen on MRI. There were elevated cobalt (4.7 ± 3.5 ppb) and chromium (4.7 ± 2.6 ppb) serum levels in patients with unilateral HRA who had an ALTR or metallosis present on MRI at year 1 compared with patients without an ALTR or metallosis on MRI (cobalt: 1.8 ± 1.0 ppb, mean difference 4.7 ppb [95% CI 3.3 to 6.0]; p < 0.001; chromium: 2.3 ± 0.5 ppb, mean difference 3.6 ppb [95% CI 2.2 to 5.0]; p < 0.001) as well as for chromium at year 3 (3.9 ± 2.4 ppb versus 2.2 ± 1.1 ppb, mean difference 1.3 ppb [95% CI 0.3 to 2.4]; p = 0.01). CONCLUSION: We found a higher proportion of ALTR or metallosis on MRI in patients with HRA compared with patients with CoP, even when patient self-assessed symptomatology of those with an ALTR or metallosis on MRI was not different than the absence of these features. MRI detected ALTRs in high-function patients, emphasizing that an annual clinical assessment dependent on survey or blood ion testing alone may not detect soft tissue complications. The results of this study are in line with prior consensus recommendations of using MRI as part of a routine follow-up protocol for this patient population. LEVEL OF EVIDENCE: Level III, therapeutic study.


Subject(s)
Foreign-Body Reaction/epidemiology , Hip Prosthesis/adverse effects , Postoperative Complications , Prosthesis Design/adverse effects , Synovitis/epidemiology , Arthroplasty, Replacement, Hip/adverse effects , Asymptomatic Diseases/epidemiology , Ceramics , Chromium/blood , Cobalt/blood , Disability Evaluation , Foreign-Body Reaction/diagnostic imaging , Foreign-Body Reaction/etiology , Hip Joint/diagnostic imaging , Hip Joint/pathology , Hip Joint/surgery , Humans , Ions/blood , Joint Capsule/diagnostic imaging , Joint Capsule/pathology , Joint Capsule/surgery , Linear Models , Longitudinal Studies , Magnetic Resonance Imaging , Metal-on-Metal Joint Prostheses/adverse effects , Patient Reported Outcome Measures , Polyethylene , Postoperative Period , Proportional Hazards Models , Prospective Studies , Prosthesis Failure , Risk Assessment , Risk Factors , Synovitis/diagnostic imaging , Synovitis/etiology , Treatment Outcome
10.
Bone Joint J ; 103-B(7): 1231-1237, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34192941

ABSTRACT

AIMS: To find out if there is an inverse association between estimated glomerular filtration rate (eGFR) and whole blood cobalt (Co) and chromium (Cr) levels in patients with metal-on-metal (MoM) hip arthroplasties and renal insufficiency, suggesting that renal insufficiency could cause accumulation of Co and Cr in blood. METHODS: Out of 2,520 patients with 3,013 MoM hip arthroplasties, we identified 1,244 patients with whole blood Co, Cr, and creatinine measured within no more than a one-year interval. We analyzed the correlation of blood metal ion levels and eGFR to identify a potential trend of accumulating Co or Cr with decreasing eGFR. RESULTS: Of the 1,244 patients, 112 had normal renal function (eGFR > 90 ml/min/1.73 m2), 715 had mild renal insufficiency (eGFR 60 to 89), 384 had moderate renal insufficiency (eGFR 30 to 59), 27 had severe renal insufficiency (eGFR 15 to 29), and six had end-stage renal insufficiency (eGFR < 15). Median eGFR was 68 ml/min/1.73 m2 (interquartile range (IQR) 56 to 82), median whole blood Co was 3.3 µg/l (IQR 1.1 to 9.9), and median Cr was 2.0 µg/l (IQR 1.2 to 3.6). We did not observe an association between decreased eGFR and increased whole blood Co and Cr concentrations, but instead both increased Co and Cr were associated with higher eGFR, indicating better kidney function. CONCLUSION: As patients with MoM hip arthroplasties get older, the prevalence of renal insufficiency among them will increase, and orthopaedic surgeons will increasingly have to evaluate whether or not this affects patient follow-up. The USA Food and Drug Administration suggests that closer follow-up may be needed for MoM patients with renal insufficiency. We did not observe accumulation of blood Co or Cr in MoM hip arthroplasty patients with mild to severe renal insufficiency. Cite this article: Bone Joint J 2021;103-B(7):1231-1237.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Chromium/blood , Cobalt/blood , Glomerular Filtration Rate , Metal-on-Metal Joint Prostheses , Adolescent , Adult , Aged , Aged, 80 and over , Creatinine/blood , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Retrospective Studies
11.
Sci Rep ; 11(1): 12352, 2021 06 11.
Article in English | MEDLINE | ID: mdl-34117287

ABSTRACT

Due to the risk of adverse reactions to metal debris resulting from increased wear of the arthroplasty more than one million metal-on-metal (MoM) hip replacements worldwide are in active follow-up. Follow-up usually includes measurement of both whole blood cobalt (Co) and chromium (Cr) concentrations. Our experience is that Cr is seldom independently elevated. We wanted to ascertain whether blood Cr measurements could be omitted from follow-up protocols without lowering the quality of follow-up. We identified 8438 whole blood Co and Cr measurements performed without or prior to revision surgery. When the cut-off levels 5 µg/L and 7 µg/L were used, Cr was independently elevated in only 0.5% (95% confidence interval, CI, 0.3 to 0.6) and 0.2% (CI 0.1 to 0.3) of the measurements. The models with continuous variables showed that the higher the blood metal concentrations are the lower the percentage of measurements with Cr higher than Co. Our results suggest that whole blood Cr is very rarely independently elevated and therefore the authorities should consider omitting Cr measurements from their screening guidelines of MoM hip replacements. We believe this change in practice would simplify follow-up and lead to cost savings without decreasing the quality of follow-up.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Chromium/blood , Cobalt/blood , Prosthesis Failure , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
12.
Reprod Toxicol ; 101: 63-73, 2021 04.
Article in English | MEDLINE | ID: mdl-33675932

ABSTRACT

We have reported sub-fertility in F1 progeny rats with gestational exposure to hexavalent chromium [Cr(VI)], which had disrupted Sertoli cell (SC) structure and function, and decreased testosterone (T). However, the underlying mechanism for reduced T remains to be understood. We tested the hypothesis "transient prenatal exposure to Cr(VI) affects testicular steroidogenesis by altering hormone receptors and steroidogenic enzyme proteins in Leydig cells (LCs)." Pregnant Wistar rats were given drinking water containing 50, 100, and 200 mg/L potassium dichromate during gestational days 9-14, encompassing fetal differentiation window of the testis from the bipotential gonad. F1 male rats were euthanized on postnatal day 60 (peripubertal rats with adult-type LCs alone). Results showed that prenatal exposure to Cr(VI): (i) increased accumulation of Cr(III) in the testis of F1 rats; (ii) increased serum levels of luteinizing and follicle stimulating hormones (LH and FSH), and 17ß estradiol, and decreased prolactin and T; (iii) decreased steroidogenic acute regulatory protein, cytochrome P450 11A1, cytochrome P450 17A1, 3ß- and 17ß-hydroxysteroid dehydrogenases, cytochrome P450 aromatase and 5α reductase proteins, (iv) decreased specific activities of 3ß and 17ß hydroxysteroid dehydrogenases; (v) decreased receptors of LH, androgen and estrogen in LCs; (vi) decreased 5α reductase and receptor proteins of FSH, androgen, and estrogen in SCs. The current study concludes that prenatal exposure to Cr(VI) disrupts testicular steroidogenesis in F1 progeny by repressing hormone receptors and key proteins of the steroidogenic pathway in LCs and SCs.


Subject(s)
Carcinogens, Environmental/toxicity , Chromium/toxicity , Potassium Dichromate/toxicity , Prenatal Exposure Delayed Effects , Testis/drug effects , 17-Hydroxysteroid Dehydrogenases/metabolism , Animals , Cholestenone 5 alpha-Reductase/metabolism , Chromium/blood , Female , Hormones/blood , Male , Maternal-Fetal Exchange , Potassium Dichromate/blood , Pregnancy , Rats, Wistar , Receptors, LH/metabolism , Receptors, Prolactin/metabolism , Receptors, Steroid/metabolism , Testis/metabolism , Testis/pathology
14.
Biol Trace Elem Res ; 199(4): 1228-1236, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32648197

ABSTRACT

Lung cancer is the leading cause of cancer-related death worldwide. Exposure to environmental and occupational carcinogens is an important cause of lung cancer. One of these substances is chromium, which is found ubiquitously across the planet. The International Agency for Research on Cancer has classified chromium(VI) as a human carcinogen. The aim of this study was to assess whether serum chromium levels, as well as DNA variants in selected genes involved in carcinogenesis, xenobiotic-metabolism, and oxidative stress could be helpful in the detection of lung cancer. We conducted a study using 218 lung cancer patients and 218 matched healthy controls. We measured serum chromium levels and genotyped ten genetic variants in ERCC2, XRCC1, MT1B, GSTP1, ABCB1, NQ01, CRTC3, GPX1, SOD2 and CAT. The odds ratios of being diagnosed with lung cancer were calculated using conditional logistic regression with respect to serum chromium level and genotypes. The odds ratio for the occurrence of lung cancer increased with increasing serum chromium levels. The difference between the quartiles with the lowest vs. highest chromium level was more than fourfold in the entire group (OR 4.52, CI 2.17-9.42, p < 0.01). This correlation was significantly increased by more than twice when specific genotypes were taken into consideration (ERCC-rs12181 TT, OR 12.34, CI 1.17-130.01, p = 0.04; CRTC3-rs12915189 non GG, OR 9.73, CI 1.58-60.10, p = 0.01; GSTP1-rs1695 non AA, OR 9.47, CI 2.06-43.49, p = < 0.01; CAT-rs1001179 non CC, OR 9.18, CI 1.64-51.24, p = 0.01). Total serum chromium levels > 0.1 µg/L were correlated with 73% (52/71) of lung cancers diagnosed with stage I disease. Our findings support the role of chromium and the influence of key proteins on lung cancer burden in the general population.


Subject(s)
Chromium , Genotype , Lung Neoplasms , Carcinogens , Chromium/blood , Female , Glutathione S-Transferase pi , Humans , Lung Neoplasms/genetics , Male , X-ray Repair Cross Complementing Protein 1 , Xeroderma Pigmentosum Group D Protein
15.
PLoS One ; 15(12): e0243492, 2020.
Article in English | MEDLINE | ID: mdl-33320863

ABSTRACT

Total reflection X-ray fluorescence analysis (TXRF) was used to determine chromium, selenium and bromine concentrations in blood serum samples of 50 patients with parenteral nutrition treatment. The concentrations were measured two times, namely in the first day (I measurement) of the treatment and the seventh day (II measurement) after the chromium and selenium supplementation. For comparison purposes also serum samples of 50 patients without nutritional disorders, admitted to a planned surgical procedure to remove the gall bladder (cholecystectomy), were analyzed and treated as the control group. Descriptive statistics of measured concentrations of Cr, Se and Br both for the studied and control groups was determined. In order to check the effectiveness of Cr and Se supplementation, the results of the first and seventh day measurements for studied group were statistically compared with each other, with literature reference values and with the results of the control group (two-group comparison). These comparisons indicate the effectiveness of selenium supplementation in the applied treatment procedure. In the case of Cr and Br concentrations no statistically significant differences were observed. We conclude that monitoring of the concentration of the important trace elements in human serum should be standard procedure in parenteral nutrition treatment. In this monitoring the TXRF technique can be successfully used.


Subject(s)
Bromine/blood , Chromium/blood , Parenteral Nutrition , Selenium/blood , Adult , Aged , Aged, 80 and over , Bromine/standards , Case-Control Studies , Chromium/standards , Female , Humans , Male , Middle Aged , Reference Values , Selenium/standards , Spectrometry, X-Ray Emission/standards
16.
Acta Orthop ; 91(6): 711-716, 2020 12.
Article in English | MEDLINE | ID: mdl-33003969

ABSTRACT

Background and purpose - The accelerated wear of poorly functioning metal-on-metal (MoM) hip implants may cause elevated whole-blood cobalt (Co) and chromium (Cr) levels. Hematological and endocrinological changes have been described as the most sensitive adverse effects due to Co exposure. We studied whether there is an association between whole-blood Co/Cr levels and leukocyte, hemoglobin, or platelet levels. Patients and methods - We analyzed whole-blood Co and Cr values and complete blood counts (including leukocytes, hemoglobin, platelets) from 1,900 patients with MoM hips. The mean age at the time of whole-blood metal ion measurements was 67 years (SD 10). The mean time from primary surgery to whole-blood metal ion measurement was 8.2 years (SD 3.0). The mean interval between postoperative blood counts and metal ion measurements was 0.2 months (SD 2.7). Results - The median Co value was 1.9 µg/L (0.2-225), Cr 1.6 µg/L (0.2-125), mean leukocyte count 6.7 × 109/L (SD 1.9), hemoglobin value 143 g/L (SD 13), and platelet count 277 × 109/L (SD 70). We did not observe clinically significant correlations between whole-blood Co/Cr and leukocyte, hemoglobin, or platelet counts. Interpretation - Elevated whole-blood Co and Cr values are unlikely to explain abnormal blood counts in patients with MoM hips and the reason for possible abnormal blood counts should be sought elsewhere.


Subject(s)
Arthroplasty, Replacement, Hip , Blood Cell Count/methods , Chromium/blood , Cobalt/blood , Hemoglobins/analysis , Metal-on-Metal Joint Prostheses/adverse effects , Prosthesis Failure/adverse effects , Aged , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Correlation of Data , Female , Finland , Hip Prosthesis , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Trace Elements/blood
17.
Spine (Phila Pa 1976) ; 45(23): 1619-1624, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-32890308

ABSTRACT

STUDY DESIGN: Prospective 2-year study with operative sampling and in-vitro analysis of chromium ions following spinal surgery in children. OBJECTIVES: To measure metal ion levels at preoperative, intraoperative, and postoperative times to determine patterns of metal ion release during instrumented spinal surgery. SUMMARY OF BACKGROUND DATA: Raised serum metal ion levels are reported following instrumented spinal fusion in adolescent idiopathic scoliosis. The authors noted raised chromium levels in patients receiving implants that did not contain chromium. This prompted further work to establish the source. The electrosurgery tips used were discovered to contain 17% chromium. METHODS: Chromium, cobalt, and titanium levels were measured before, during, and after surgery in serum and local intraoperative fluid samples in 11 children undergoing posterior instrumentation for scoliosis. Administered drugs, cell-saver fluids, and intraoperative fluids, both local and intravenous, were investigated to exclude these as sources of chromium ions. An in-vitro study was also performed to elucidate sources of intraoperative chromium ions. RESULTS: High chromium levels were detected in all samples from the wound irrigation fluid prior to insertion of metal implants. Immediate postoperative chromium serum ion levels were also elevated and returned to baseline by day 30. In-vitro sampling of fluids from test models using electrosurgery revealed high levels of chromium ions CONCLUSION.: This finding of high chromium metal ion concentrations in intraoperative and early postoperative samples provides evidence of chromium release during the dissection phase of spinal surgery. This challenges existing beliefs that metal ion release occurs solely due to implants and now implicates the electrosurgery electrode tips as a source of raised chromium ion levels. Thorough irrigation of the operative site after the dissection phase of surgery to both dilute and reduce the intraoperative chromium ion load is suggested. Alternative electrosurgery electrode tips or other methods to coagulate during surgery could be considered. LEVEL OF EVIDENCE: 2.


Subject(s)
Chromium/blood , Electrosurgery/adverse effects , Prostheses and Implants/adverse effects , Scoliosis/blood , Scoliosis/surgery , Spinal Fusion/adverse effects , Adolescent , Child , Electrosurgery/instrumentation , Electrosurgery/methods , Female , Humans , Ions/blood , Longitudinal Studies , Male , Metals, Heavy/blood , Monitoring, Intraoperative/methods , Prospective Studies , Spinal Fusion/instrumentation , Spinal Fusion/methods , Treatment Outcome
18.
Arch Orthop Trauma Surg ; 140(12): 2085-2089, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32940804

ABSTRACT

Recently, catastrophic failure (i.e., dissociation between the metal femoral head and stem due to stem neck deformation) after total hip arthroplasty (THA) has been reported. Early detection of this complication is very important, because it is accompanied by an increased cobalt concentration in the body, which might influence systemic conditions such as heart failure and immune system diseases. However, early detection of stem neck deformation is considered as difficult. In most cases in the literatures, the diagnosis was made at the time of acute dissociation. We report a case of early detection of stem neck deformation with the 'Bowing-head sign' before acute dissociation. The patient is a 71-year old woman complained of a clicking sensation in the right hip during regular follow-up after THA with a 32-mm cobalt/chromium head with polyethylene insert for osteoarthritis performed 7 years previously. The plain radiograph showed that the angle between the metal femoral head and the axis of the stem neck was not perpendicular ('Bowing-head sign'). Dynamic evaluation under fluoroscopy showed movement of the stem neck in the metal femoral head with hip abduction and adduction. Laboratory data showed abnormal serum cobalt (6.3 µg/L, normal < 1 µg/L) and chromium (3.8 µg/L, normal < 5 µg/L) levels. Considering those radiographic findings, deformation of the stem neck due to trunnionosis was diagnosed, and elective revision surgery was performed without any complications. Plain radiographs after THA should be assessed with attention to this complication, 'Bowing-head sign' must not be overlooked.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Joint/diagnostic imaging , Hip Prosthesis , Prosthesis Failure , Aged , Chromium/blood , Chromium Alloys , Cobalt/blood , Early Diagnosis , Early Medical Intervention , Female , Femur Head/surgery , Humans , Metals , Osteoarthritis, Hip/surgery , Polyethylene , Radiography , Reoperation/methods
19.
Sci Rep ; 10(1): 13948, 2020 08 18.
Article in English | MEDLINE | ID: mdl-32811884

ABSTRACT

Ischemic heart disease (IHD) is the leading cause of death and chronic disability in the world. IHD affects both the systolic and diastolic function of the heart which progressively leads to heart failure; a structural and functional impairment of filling or ejection of blood from the heart. In this study, the progression of systolic and diastolic dysfunction characterized according to their echocardiographic parameters including left ventricular ejection fraction (EF), grades of diastolic dysfunction and ratio between early mitral inflow velocity and mitral annular early diastolic velocity (E/e'), were correlated with differential regulation of various metals in patients sera samples (n = 62) using inductive coupled plasma-mass spectrometry (ICP-MS). Chromium, nickel and selenium were found significant (p < 0.05) in patients having EF < 45% compared with EF > 45%. In patients with systolic dysfunction (EF < 45%), the level of selenium was decreased while the level of chromium and nickel was increased compared to patients with EF > 45%. Selenium level was also decreased significantly (p < 0.05) in grade 1A and 2 patients that are considered as higher grades of diastole dysfunction in comparison to grade 0-1. Overall, selenium deficiency was identified in both systolic and diastolic dysfunctions of IHD patients corresponding to the progression of disease that could be related to many metabolic and translational pathways specifically which involve selenoproteins.


Subject(s)
Heart Failure/physiopathology , Metals/analysis , Myocardial Ischemia/metabolism , Adult , Blood Pressure/physiology , Cardiomyopathies/physiopathology , Chromium/analysis , Chromium/blood , Diastole/physiology , Echocardiography, Doppler , Female , Humans , Male , Metals/blood , Middle Aged , Mitral Valve/physiopathology , Nickel/analysis , Nickel/blood , Selenium/analysis , Selenium/blood , Stroke Volume/physiology , Systole/physiology , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left/physiology
20.
J Int Soc Sports Nutr ; 17(1): 35, 2020 Jul 09.
Article in English | MEDLINE | ID: mdl-32646441

ABSTRACT

BACKGROUND: The aim of the present study was to determine changes occurring in the erythrocyte concentrations of chromium (Cr), copper (Cu), manganese (Mn), molybdenum (Mo), selenium (Se) and zinc (Zn) in male subjects with different training levels living in the same region (Spain). METHODS: Thirty sedentary subjects (24.34 ± 3.02 years) formed the control group (CG); 24 moderately trained (4-7 h/week) subjects (23.53 ± 1.85 years) formed the group with a moderate degree of training (MTG) and 22 professional cyclists (23.29 ± 2.73 years), who performed more than 20 h/week of training, formed the high-level training group (HTG). Erythrocyte samples were collected from all subjects in fasting conditions, washed and frozen at - 80 °C until analysis. Erythrocyte analysis of trace elements was performed by inductively coupled plasma mass spectrometry (ICP-MS). RESULTS: The results showed that there was a statistically significant lower erythrocyte concentration of Cu, Mn, Mo and Zn in the MTG and HTG than CG. Se was only significantly lower in HTG than CG. The correlation analysis indicates that this change was correlated with training in the case of Cu, Mn, Se and Zn. All results are expressed in µg/g Hb. CONCLUSIONS: We can conclude that physical training produces a decrease in erythrocyte concentrations of Cu, Mn, Se and Zn, which can cause a decrement in athletes' performance given the importance of these elements. For this reason, erythrocyte monitoring during the season would seem to be advisable to avoid negative effects on performance.


Subject(s)
Erythrocytes/chemistry , Physical Fitness , Trace Elements/blood , Chromium/blood , Copper/blood , Humans , Male , Manganese/blood , Molybdenum/blood , Selenium/blood , Spain , Young Adult , Zinc/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...