Results 1 - 20 de 4.680
Filter
1.
J Long Term Eff Med Implants ; 34(4): 33-47, 2024.
Article in English | MEDLINE | ID: mdl-38842231

ABSTRACT

This virtual study was designed to evaluate the stress-deformation of a metal fixed partial dentures (FPDs) pontic under different loads using two different connectors. The STL file was generated for a RPD of two implant-supported restorations. The Co-Cr metal substructure was designed with two types of connector design. The pontic is connected to implant-supported crowns with square and round shape connectors. This study was designed for a cementless-retained implant-supported FPD. Finite element modeling (FEM) is used to assess the stress and deformation of the pontic within a metal substructure as the FEM might provide virtual values that could have laboratory and clinical relevance. The Co-Cr alloy mechanical properties like the Poisson ratio and modulus of elasticity were based on the parameters of the three-dimensional structure additive method. Nonparametric analyses (Mann-Whitney U test) was used. The use of square or round connectors often resulted in non-significant changes in stress, and deformation under either three or each loaded point on the occlusal surface of a pontic (P > 0.05). However, the deformation revealed distinct variations between loads of the three points compared to each loaded point (P ≤ 0.05). According to this study data, the pontic occlusal surface appears to be the same in stress and deformation under different loads depending on whether square or round connectors are used. While at the same connector designs, the pontic occlusal surface deformed significantly at three loaded points than it did at each point.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Finite Element Analysis , Humans , Chromium Alloys/chemistry , Denture Design , Dental Stress Analysis , Stress, Mechanical
2.
JACC Cardiovasc Interv ; 17(9): 1119-1130, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38749592

ABSTRACT

BACKGROUND: There was no study evaluating the effects of an aspirin-free strategy in patients undergoing complex percutaneous coronary intervention (PCI). OBJECTIVES: The authors aimed to evaluate the efficacy and safety of an aspirin-free strategy in patients undergoing complex PCI. METHODS: We conducted the prespecified subgroup analysis based on complex PCI in the STOPDAPT-3 (ShorT and OPtimal duration of Dual AntiPlatelet Therapy after everolimus-eluting cobalt-chromium stent-3), which randomly compared low-dose prasugrel (3.75 mg/d) monotherapy to dual antiplatelet therapy (DAPT) with low-dose prasugrel and aspirin in patients with acute coronary syndrome or high bleeding risk. Complex PCI was defined as any of the following 6 criteria: 3 vessels treated, ≥3 stents implanted, ≥3 lesions treated, bifurcation with 2 stents implanted, total stent length >60 mm, or a target of chronic total occlusion. The coprimary endpoints were major bleeding events (Bleeding Academic Research Consortium 3 or 5) and cardiovascular events (a composite of cardiovascular death, myocardial infarction, definite stent thrombosis, or ischemic stroke) at 1 month. RESULTS: Of the 5,966 study patients, there were 1,230 patients (20.6%) with complex PCI. Regardless of complex PCI, the effects of no aspirin relative to DAPT were not significant for the coprimary bleeding (complex PCI: 5.30% vs 3.70%; HR: 1.44; 95% CI: 0.84-2.47; P = 0.18 and noncomplex PCI: 4.26% vs 4.97%; HR: 0.85; 95% CI: 0.65-1.11; P = 0.24; P for interaction = 0.08) and cardiovascular (complex PCI: 5.78% vs 5.93%; HR: 0.98; 95% CI: 0.62-1.55; P = 0.92 and noncomplex PCI: 3.70% vs 3.10%; HR: 1.20; 95% CI: 0.88-1.63; P = 0.25; P for interaction = 0.48) endpoints without significant interactions. CONCLUSIONS: The effects of the aspirin-free strategy relative to standard DAPT for the cardiovascular and major bleeding events were not different regardless of complex PCI. (ShorT and OPtimal duration of Dual AntiPlatelet Therapy after everolimus-eluting cobalt-chromium stent-3 [STOPDAPT-3]; NCT04609111).


Subject(s)
Aspirin , Coronary Artery Disease , Drug Administration Schedule , Drug-Eluting Stents , Dual Anti-Platelet Therapy , Everolimus , Hemorrhage , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Prasugrel Hydrochloride , Prosthesis Design , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/mortality , Platelet Aggregation Inhibitors/adverse effects , Platelet Aggregation Inhibitors/administration & dosage , Male , Time Factors , Female , Aspirin/administration & dosage , Aspirin/adverse effects , Aspirin/therapeutic use , Aged , Middle Aged , Treatment Outcome , Hemorrhage/chemically induced , Hemorrhage/prevention & control , Risk Factors , Prasugrel Hydrochloride/administration & dosage , Prasugrel Hydrochloride/adverse effects , Prasugrel Hydrochloride/therapeutic use , Everolimus/administration & dosage , Everolimus/adverse effects , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Coronary Thrombosis/prevention & control , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/diagnostic imaging , Chromium Alloys , Risk Assessment , Drug Therapy, Combination
3.
Int J Prosthodont ; 37(7): 187-193, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787583

ABSTRACT

PURPOSE: To characterize material changes that may occur in virgin cobalt-chromium (Co-Cr) alloy powder when it is blended with alloy powders that have been reused multiple times. MATERIALS AND METHODS: Initially, 20 kg of virgin Co-Cr powder was loaded into a laser-sintering device. The tensile test specimens were fabricated in the first (Group 1), fourth (Group 2), seventh (Group 3), tenth (Group 4), and thirteenth (Group 5) production cycles (N = 15). Prior to fabricating the specimens, powder alloy samples were collected from the powder bed for analysis. The tensile strength, elastic modulus, and percent elongation were calculated with tensile testing. Scanning electron microscopy and energy dispersive x-ray spectroscopy (SEM/EDS) and laser particle size distribution (LPSD) were used to analyze the alloy powder samples. The fracture surface of one tensile test specimen from each group was examined via SEM/EDS. One-way ANOVA followed by Dunnett T3 test was used for statistical analysis (α = .05). RESULTS: No difference was observed between groups in terms of tensile strength. A statistically significant difference was observed between Groups 1 and 2 in terms of percent elongation. Groups 2 and 4 were statistically significantly different in terms of both elastic modulus and percent elongation (P ≤ .05). SEM images of the powder alloy showed noticeable differences with increasing numbers of cycles. SEM images and the EDS analysis of the fractured specimens were in accordance with the strength data. CONCLUSIONS: Reusing Co-Cr alloy powder increased the particle size distribution. However, there was no correlation between increased cycle number and the mechanical properties of the powder.


Subject(s)
Chromium Alloys , Materials Testing , Microscopy, Electron, Scanning , Particle Size , Powders , Tensile Strength , Chromium Alloys/chemistry , Elastic Modulus , Spectrometry, X-Ray Emission , In Vitro Techniques , Surface Properties
4.
J Biomed Mater Res B Appl Biomater ; 112(6): e35431, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38817036

ABSTRACT

Cobalt-Chromium (CoCr) alloys are currently used for various cardiovascular, orthopedic, fracture fixation, and dental implants. A variety of processes such as casting, forging, wrought processing, hot isostatic pressing, metal injection molding, milling, selective laser melting, and electron beam melting are used in the manufacture of CoCr alloy implants. The microstructure and precipitates (carbides, nitrides, carbonitrides, and intermetallic compounds) formed within the alloy are primarily determined by the type of manufacturing process employed. Although the effects of microstructure and precipitates on the physical and mechanical properties of CoCr alloys are well reviewed and documented in the literature, the effects on corrosion resistance and biocompatibility are not comprehensively reviewed. This article reviews the various processes used to manufacture CoCr alloy implants and discusses the effects of manufacturing processes on corrosion resistance and biocompatibility. This review concludes that the microstructure and precipitates formed in the alloy are unique to the manufacturing process employed and have a significant impact on the corrosion resistance and biocompatibility of CoCr alloys. Additionally, a historical and scientific overview of corrosion and biocompatibility for metallic implants is included in this review. Specifically, the failure of CoCr alloys when used in metal-on-metal bearing surfaces of total hip replacements is highlighted. It is recommended that the type of implant/application (orthopedic, dental, cardiovascular, etc.) should be the first and foremost factor to be considered when selecting biomaterials for medical device development.


Subject(s)
Chromium Alloys , Materials Testing , Humans , Corrosion , Chromium Alloys/chemistry , Animals , Biocompatible Materials/chemistry , Prostheses and Implants
5.
Int J Prosthodont ; 37(7): 285-307, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38819942

ABSTRACT

PURPOSE: The purpose of this systematic review and meta-analysis was to compare the influence of fabrication method (conventional, subtractive, and additive procedures) and manufacturing trinomial (technology, printer, and material combination) on the marginal and internal fit of cobaltchromium (Co-Cr) tooth-supported frameworks. MATERIALS AND METHODS: An electronic systematic review was performed in five data bases: MEDLINE/PubMed, Embase, World of Science, Cochrane, and Scopus. Studies that reported the marginal and internal discrepancies of tooth-supported Co-Cr additive manufacturing (AM) frameworks were included. Two authors independently completed the quality assessment of the studies by applying the Joanna Briggs Institute Critical Appraisal Checklist for Quasi-Experimental Studies. A third examiner was consulted to resolve lack of consensus. RESULTS: A total of 31 articles were included and classified based on the evaluation method: manufacturing accuracy, the dual- or triple-scan method, stereomicroscope, optical coordinate measurement machine, microCT, profilometer, and silicone replica. Six subgroups were created: 3D Systems, Bego, Concept Laser, EOS, Kulzer, and Sisma. Due to the heterogeneity and limited data available, only the silicone replica group was considered for meta-analysis. The metaanalysis showed a mean marginal discrepancy of 91.09 µm (I2 = 95%, P < .001) in the conventional group, 77.48 µm (I2 = 99%, P < .001) in the milling group, and 82.92 µm (I2 = 98%, P < .001) in the printing group. Additionally, a mean internal discrepancy of 111.29 µm (I2 = 94%, P < .001) was obtained in the conventional casting group, 121.96 µm (I2 = 100%, P < .001) in the milling group, and 121.25 µm (I2 = 99%, P < .001) in the printing group. CONCLUSIONS: Manufacturing method and selective laser melting (SLM) metal manufacturing trinomial did not impact the marginal and internal discrepancies of Co-Cr frameworks for the fabrication of tooth-supported restorations.


Subject(s)
Chromium Alloys , Computer-Aided Design , Humans , Chromium Alloys/chemistry , Dental Marginal Adaptation , Printing, Three-Dimensional , Denture Design , Dental Prosthesis Design , Technology, Dental , Dental Materials/chemistry
6.
J Dent ; 144: 104987, 2024 May.
Article in English | MEDLINE | ID: mdl-38580056

ABSTRACT

OBJECTIVES: To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS: A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS: Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS: Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE: Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.


Subject(s)
Computer-Aided Design , Crowns , Dental Porcelain , Dental Prosthesis Design , Materials Testing , Dental Porcelain/chemistry , Humans , Dental Abutments , Ceramics/chemistry , Surface Properties , Dental Materials/chemistry , Dental Marginal Adaptation , Chromium Alloys/chemistry
7.
J Mech Behav Biomed Mater ; 154: 106539, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38598917

ABSTRACT

PURPOSE: Polyetheretherketone (PEEK) is considered as an alternative to metal material for removable partial denture (RPD). However, the retentive force is not strong as a metal RPD. This study investigated the retention and fatigue performance of PEEK clasps with different proportions of clasp arm engaging the undercut to verify a new strategy to improve their clinical performance. METHODS: Three groups (n = 10/group) of PEEK clasps with their terminal 1/3, 2/3 and the whole of retentive arms engaging the undercut were fabricated along with a group (n = 10) of conventional cobalt-chrome (CoCr) clasps as control group. Retentive forces were measured by universal testing machine initially and at an interval of 1500 cycles for a total of 15,000 fatigue cycles. The fatigue cycles were conducted by repeated insertion and removal of the clasp using fatigue testing machine. Each clasp was scanned by Trios3 scanner before and after fatigue test to obtain digital models. The deformation of the clasp was evaluated by root mean square (RMS) through aligning the two models in Geomagic wrap (2021). Scanning electron microscopy (SEM) and finite element analysis were carried out to observe the abrasion and the von Mises stress of the clasp arm. Kruskal-Wallis H test was used to compare the retentive forces and the RMSs of the studied groups followed by Bonferroni multiple comparisons. RESULTS: The whole of PEEK clasp arm engaging the undercut provided higher mean retentive forces (7.99 ± 2.02 N) than other PEEK clasp groups (P < 0.001) and was closer to CoCr clasps (11.88 ± 2.05 N). The RMSs of PEEK clasps were lower than CoCr clasps (P < 0.05) while the differences among PEEK clasps were of no statistical significance (P > 0.05). SEM showed that evidences of surface abrasion were observed on the section that engaged the undercut for all groups of clasps. The stress concentration mainly occurred on the initial part of the retentive arm. The maximum von Mises stress of each group was below the compressive strength of PEEK. CONCLUSIONS: Proportions of PEEK clasp arm engaging the undercut positively influenced the retentive force and the fatigue resistance of PEEK clasps was superior than CoCr clasps. It is a feasible method to improve the retention of PEEK clasps by increasing the proportion of clasp arm engaging the undercut. Clinical trials are needed to further verify this innovation.


Subject(s)
Benzophenones , Denture Retention , Denture, Partial, Removable , Polyethylene Glycols , Polymers , Ketones , Chromium Alloys , Dental Stress Analysis , Dental Clasps
9.
J Indian Prosthodont Soc ; 24(2): 201-207, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38650346

ABSTRACT

AIMS: The objectives of the study were to compare the adaptation of presintered zirconia and cobalt- chromium prostheses using microcomputed tomography (µCT), scanning electron microscopy (SEM), and stereomicroscope (SM). MATERIALS AND METHODS: Twenty-four fixed dental prostheses (FDPs) were fabricated on metal abutments, duplicated from maxillary first premolar and first molar prepared on a typodont model. Teeth were reduced to obtain chamfer of 1.2 mm and reduction occlusaly of 2 mm occlusal. Scanning of the abutments was done with random assignment to two groups receiving the FDPs made from soft-milled Co-Cr (n = 12) and zirconia (n = 12). Marginal and internal gaps were assessed using three evaluation techniques (X-ray microcomputer tomography, SEM, and stereomicroscopy). STATISTICAL ANALYSIS USED: Comparison of the results was made using Levene and analysis of variance tests (α =0.05). RESULTS: Irrespective of the material tested, statistical differences were found between the measuring techniques (P = 0.001 overall); the obtained mean gaps were for CT scan (92.60 ± 13.31), for SEM (101.92 ± 23.03), and for SM (113.44 ± 14.68): the multiple comparisons between techniques found a significant difference between CT and SM (P < 0.001), and SEM and SM (P = 0.025). When materials were compared within each measuring technique, Co-Cr showed lower values compared to zirconia in SEM (P < 0.001) and Stereo (P = 0.049); similar results were found in CT. CONCLUSIONS: Results values differed with the chosen measuring technique. Co-Cr prostheses had a better fit than zirconia prostheses in SEM and Stereo. µCT showed comparable results to SEM, smaller than SM results.


Subject(s)
Chromium Alloys , Microscopy, Electron, Scanning , X-Ray Microtomography , Zirconium , Zirconium/chemistry , X-Ray Microtomography/methods , Chromium Alloys/chemistry , Humans , Dental Prosthesis Design/methods
10.
Biosensors (Basel) ; 14(3)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38534259

ABSTRACT

Accurate sample heating is vital for nucleic acid extraction and amplification, requiring a sophisticated thermal cycling process in nucleic acid detection. Traditional molecular detection systems with heating capability are bulky, expensive, and primarily designed for lab settings. Consequently, their use is limited where lab systems are unavailable. This study introduces a technique for performing the heating process required in molecular diagnostics applicable for point-of-care testing (POCT), by presenting a method for crafting customized heaters using freely patterned nichrome (NiCr) wire. This technique, fabricating heaters by arranging protrusions on a carbon black-polydimethylsiloxane (PDMS) cast and patterning NiCr wire, utilizes cost-effective materials and is not constrained by shape, thereby enabling customized fabrication in both two-dimensional (2D) and three-dimensional (3D). To illustrate its versatility and practicality, a 2D heater with three temperature zones was developed for a portable device capable of automatic thermocycling for polymerase chain reaction (PCR) to detect Escherichia coli (E. coli) O157:H7 pathogen DNA. Furthermore, the detection of the same pathogen was demonstrated using a customized 3D heater surrounding a microtube for loop-mediated isothermal amplification (LAMP). Successful DNA amplification using the proposed heater suggests that the heating technique introduced in this study can be effectively applied to POCT.


Subject(s)
Chromium Alloys , Escherichia coli O157 , Nucleic Acids , Pathology, Molecular , Nucleic Acid Amplification Techniques/methods , DNA , Molecular Diagnostic Techniques/methods
11.
J Mech Behav Biomed Mater ; 153: 106474, 2024 May.
Article in English | MEDLINE | ID: mdl-38447273

ABSTRACT

Total Hip Arthroplasty has been a revolutionary technique in restoring mobility to patients with damaged hip joints. The introduction of modular components of the hip prosthesis allowed for bespoke solutions based on the requirements of the patient. The femoral stem is designed with a conical trunnion to allow for assembly of different femoral head sizes based on surgical requirements. The femoral head diameters for a metal-on-polyethylene hip prosthesis have typically ranged between 22 mm and 36 mm and are typically manufactured using Cobalt-Chromium alloy. A smaller femoral head diameter is associated with lower wear of the polyethylene, however, there is a higher risk of dislocation. In this study, a finite element model of a standard commercial hip arthroplasty prosthesis was modelled with femoral head diameters ranging from 22 mm to 36 mm to investigate the wear evolution and material loss at both contacting surfaces (acetabular cup and femoral stem trunnion). The finite element model, coupled with a validated in-house wear algorithm modelled a human walking for 10 million steps. The results have shown that as the femoral head size increased, the amount of wear on all contacting surfaces increased. As the femoral head diameter increased from 22 mm to 36 mm, the highly cross-linked polyethylene (XLPE) volumetric wear increased by 61% from 98.6 mm3 to 159.5 mm3 while the femoral head taper surface volumetric wear increased by 21% from 4.18 mm3 to 4.95 mm3. This study has provided an insight into the amount of increased wear as the femoral head size increased which can highlight the life span of these prostheses in the human body.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Femur Head , Finite Element Analysis , Prosthesis Design , Prosthesis Failure , Polyethylene , Chromium Alloys
12.
Niger J Clin Pract ; 27(3): 368-375, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38528358

ABSTRACT

BACKROUND: The evolution of restorative materials in prosthodontics has led to the emergence of indirect composite resins, including ceromers, as alternatives to traditional metal-ceramic restorations. However, research gaps exist regarding the impact of ageing protocols on the bond strength of ceromer composites to different metal substructures, necessitating further investigation in this area. AIM: This study aimed to determine the effect of five different ageing protocols on the shear bond strength (SBS) of ceromer indirect composites on two different substructures. METHODS: In this in vitro study, 120 metallic discs (10 × 2 mm) were cast from cobalt-chromium (Co-Cr) alloy (n = 60) and spark erosion treated from grade V titanium (n = 60). Each sample was sandblasted. The M.L. primer (Shofu, Germany) and layers of opaque were applied to the surface following the manufacturer's instructions. A special jig (6 × 2 mm) was placed on each disc. The ceromer was condensed in it and light-cured separately for 90 s. Following polishing, specimens were separated into five ageing groups: distilled water (as a control), thermal cycling, tea, coffee, and gastric acid immersion. All samples were placed in 37°C incubation for 28 days for distilled water, coffee, and tea, and 7 days for gastric acid immersion and thermal cycling for 5000 cycles (5-55°C). A universal test machine was used to measure the SBS. The samples were evaluated for failure modes using stereomicroscopy. Data were analyzed using one-way analysis of variance (ANOVA) (P < 0.05). RESULTS: According to one-way ANOVA, the mean SBS (MPa) between the two groups was compared in each ageing protocol, and there were no significant differences between the Co-Cr-C and Ti-C groups (P > 0.05). The most frequent mode of failure in all groups was mixed. CONCLUSIONS: Applying the ageing protocols, the type of substructure material had no significant effect on the SBS of the ceromer indirect composite except for tea immersion.


Subject(s)
Coffee , Dental Bonding , Methacrylates , Humans , Surface Properties , Composite Resins/chemistry , Ceramics , Chromium Alloys/chemistry , Water/chemistry , Tea , Materials Testing , Shear Strength , Dental Stress Analysis
13.
Int J Prosthodont ; 37(7): 41-47, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38489219

ABSTRACT

PURPOSE: This in vitro study evaluated the adaptation of cobalt-chromium (Co-Cr) fixed dental prostheses (FDPs) fabricated by selective laser melting (SLM) with different build angles. MATERIALS AND METHODS: Maxillary right first premolars and first molars from a typodont were prepared with 1-mm chamfer, 2-mm occlusal reduction, and total taper of 8 degrees to receive three-unit FDPs. After framework design, data were sent to a laser machine, and 30 specimens were fabricated from Co-Cr metal powder by SLM. Specimens were assigned to three groups (n = 10 per group) with different build angles of 0 (A0), 30 (A30), and 45 (A45) degrees. Marginal and internal fit were evaluated. Results were compared among build orientation groups and abutments. Data were analyzed using the Levene test, t test, and analysis of variance (α = .05). RESULTS: A statistical difference was found between different angle groups (P = .015). At the abutment level, a significant difference was found in the gap values between build orientation groups for the molars (P = .048). Group A0 reported the smallest mean discrepancy values, and group A45 the highest. Statistical differences were found between group A45 and groups A0 (P < .001) and A30 (P < .024). CONCLUSIONS: The fit of printed metal FDPs was affected by the build orientation but remained clinically acceptable.


Subject(s)
Chromium Alloys , Computer-Aided Design , Dental Marginal Adaptation , Cobalt , Chromium , Denture, Partial, Fixed , Dental Prosthesis Design
14.
Dent Mater J ; 43(2): 235-246, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38417861

ABSTRACT

Prosthetic biomaterials can affect the composition of the subgingival microbiota and consequently the production of proinflammatory cytokines, causing damage to the periodontium. A total of 40 patients were divided into two groups: 20 with monolithic zirconia (MZ) prostheses and 20 with porcelain fused to metal (PFM) with nickel-chromium (Ni-Cr) alloy prostheses. Subgingival plaque and gingival crevicular fluid samples were taken. The Checkerboard technique for DNA-DNA hybridization and the enzyme-linked immunosorbent assay technique were performed. Teeth with MZ presented a lower percentage of bleeding on probing and tooth mobility compared to teeth with PFM with Ni-Cr alloy. Prosthodontic teeth harbored higher total levels of the 18 bacterial species than non-prosthodontic teeth. There was a higher prevalence of S. gordonii and V. parvula species in PFM with Ni-Cr alloy compared to MZ. There was an increase in IL-1ß, TNF-α and CX3CL1 levels in PFM with Ni-Cr alloy compared to MZ. MZ is a candidate biomaterial with fewer negative effects on the periodontium, allowing for longer prostheses longevity in the mouth.


Subject(s)
Dental Prosthesis , Microbiota , Humans , Gingival Crevicular Fluid , Tumor Necrosis Factor-alpha , Chromium Alloys , Dental Porcelain , DNA , Chemokine CX3CL1
15.
Bone Joint J ; 106-B(3 Supple A): 38-43, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38423114

ABSTRACT

Aims: Oxidized zirconium (OxZi) and highly cross-linked polyethylene (HXLPE) were developed to minimize wear and risk of osteolysis in total hip arthroplasty (THA). However, retrieval studies have shown that scratched femoral heads may lead to runaway wear, and few reports of long-term results have been published. The purpose of this investigation is to report minimum ten-year wear rates and clinical outcomes of THA with OxZi femoral heads on HXLPE, and to compare them with a retrospective control group of cobalt chrome (CoCr) or ceramic heads on HXLPE. Methods: From 2003 to 2006, 108 THAs were performed on 96 patients using an OxZi head with a HXLPE liner with minimum ten-year follow-up. Harris Hip Scores (HHS) were collected preoperatively and at the most recent follow-up (mean 13.3 years). Linear and volumetric liner wear was measured on radiographs of 85 hips with a minimum ten-year follow-up (mean 14.5 years). This was compared to a retrospective control group of 45 THAs using ceramic or CoCr heads from October 1999 to February 2005, with a minimum of ten years' follow-up. Results: Average HHS improved from 50.8 to 91.9 and 51.0 to 89.8 in the OxZi group and control group, respectively (p = 0.644), with no osteolysis in either group. Linear and volumetric wear rates in the OxZi group averaged 0.03 mm/year and 3.46 mm3/year, respectively. There was no statistically significant difference in HHS scores, nor in linear or volumetric wear rate between the groups, and no revision for any indication. Conclusion: The radiological and clinical outcomes, and survivorship of THA with OxZi femoral heads and HXLPE liners, were excellent, and comparable to CoCr or ceramic heads at minimum ten-year follow-up. Wear rates are below what would be expected for development of osteolysis. OxZi-HXLPE is a durable bearing couple with excellent long-term outcomes.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Osteolysis , Humans , Polyethylene , Zirconium , Retrospective Studies , Femur Head/surgery , Osteolysis/etiology , Osteolysis/surgery , Prosthesis Failure , Prosthesis Design , Chromium Alloys
16.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(1): 71-79, 2024 Jan 09.
Article in Chinese | MEDLINE | ID: mdl-38228542

ABSTRACT

Objective: To develop and evaluate metal artifact removal systems (MARS) based on deep learning to assess their effectiveness in removing artifacts caused by different thicknesses of metals in cone-beam CT (CBCT) images. Methods: A full-mouth standard model (60 mm×75 mm×110 mm) was three-dimensional (3D) printed using photosensitive resin. The model included a removable and replaceable target tooth position where cobalt-chromium alloy crowns with varying thicknesses were inserted to generate matched CBCT images. The artifacts resulting from cobalt-chromium alloys with different thicknesses were evaluated using the structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). CNN-MARS and U-net-MARS were developed using a convolutional neural network and U-net architecture, respectively. The effectiveness of both MARSs were assessed through visualization and by measuring SSIM and PSNR values. The SSIM and PSNR values were statistically analyzed using one-way analysis of variance (α=0.05). Results: Significant differences were observed in the range of artifacts produced by different thicknesses of cobalt-chromium alloys (all P<0.05), with 1 mm resulting in the least artifacts. The SSIM values for specimens with thicknesses of 1.0, 1.5, and 2.0 mm were 0.916±0.019, 0.873±0.010, and 0.833±0.010, respectively (F=447.89, P<0.001). The corresponding PSNR values were 20.834±1.176, 17.002±0.427, and 14.673±0.429, respectively (F=796.51, P<0.001). After applying CNN-MARS and U-net-MARS to artifact removal, the SSIM and PSNR values significantly increased for images with the same thickness of metal (both P<0.05). When using the CNN-MARS for artifact removal, the SSIM values for 1.0, 1.5 and 2.0 mm were 0.938±0.023, 0.930±0.029, and 0.928±0.020 (F=2.22, P=0.112), while the PSNR values were 30.938±1.495, 30.578±2.154 and 30.553±2.355 (F=0.54, P=0.585). When using the U-net-MARS for artifact removal, the SSIM values for 1.0, 1.5 and 2.0 mm were 0.930±0.024, 0.932±0.017 and 0.930±0.012 (F=0.24, P=0.788), and the PSNR values were 30.291±0.934, 30.351±1.002 and 30.271±1.143 (F=0.07, P=0.929). No significant differences were found in SSIM and PSNR values after artifact removal using CNN-MARS and U-net-MARS for different thicknesses of cobalt-chromium alloys (all P>0.05). Visualization demonstrated a high degree of similarity between the images before and after artifact removal using both MARS. However, CNN-MARS displayed clearer metal edges and preserved more tissue details when compared with U-net-MARS. Conclusions: Both the CNN-MARS and U-net-MARS models developed in this study effectively remove the metal artifacts and enhance the image quality. CNN-MARS exhibited an advantage in restoring tissue structure information around the artifacts compared to U-net-MARS.


Subject(s)
Deep Learning , Artifacts , Cone-Beam Computed Tomography/methods , Chromium Alloys , Crowns , Image Processing, Computer-Assisted/methods
17.
Chemosphere ; 351: 141185, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38215831

ABSTRACT

Chromium-containing wastewater causes serious environmental pollution due to the harmfulness of Cr(VI). The ferrite process is typically used to treat chromium-containing wastewater and recycle the valuable chromium metal. However, the current ferrite process is unable to fully transform Cr(VI) into chromium ferrite under mild reaction conditions. This paper proposes a novel ferrite process to treat chromium-containing wastewater and recover valuable chromium metal. The process combines FeSO4 reduction and hydrothermal treatment to remove Cr(VI) and form chromium ferrite composites. The Cr(VI) concentration in the wastewater was reduced from 1040 mg L-1 to 0.035 mg L-1, and the Cr(VI) leaching toxicity of the precipitate was 0.21 mg L-1 under optimal hydrothermal conditions. The precipitate consisted of micron-sized ferrochromium spinel multiphase with polyhedral structure. The mechanism of Cr(VI) removal involved three steps: 1) partial oxidation of FeSO4 to Fe(III) hydroxide and oxy-hydroxide; 2) reduction of Cr(VI) by FeSO4 to Cr(III) and Fe(III) precipitates; 3) transformation and growth of the precipitates into chromium ferrite composites. This process meets the release standards of industrial wastewater and hazardous waste and can improve the efficiency of the ferrite process for toxic heavy metal removal.


Subject(s)
Aluminum Oxide , Chromium Alloys , Magnesium Oxide , Wastewater , Water Pollutants, Chemical , Ferric Compounds/chemistry , Chromium/chemistry , Hydroxides , Water Pollutants, Chemical/analysis
18.
J Prosthodont ; 33(1): 77-85, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36704924

ABSTRACT

PURPOSE: To measure the wear at the implant interface between the Grade 4 titanium (Ti) of the implant and frameworks fabricated using two additively manufactured alloys (Ti alloy and cobalt-chromium [Co-Cr]) pre- and post-artificial aging. MATERIAL AND METHODS: Three-unit frameworks supported by two implants were additively manufactured (Atlantis; Dentsply Sirona) using Ti and Co-Cr dental alloys. Two implants (OsseoSpeed EV, Astra Tech; Dentsply Sirona) were torqued on each non-engaging framework. The assembled implant-frameworks were secured into polyurethane foam blocks. Groups were created based on the material and surface assessed: framework (Ti-framework and Co-Cr-framework groups) and implant (Ti-implant group). Two subgroups were created depending on the location: premolar (PM) and molar (M). Computed tomography images were obtained pre- (as manufactured) and post-simulated mastication procedures. The pre- and post-simulated mastication files of each specimen were aligned using the best-fit algorithm using a metrology program. Wear was measured by calculating the volumetric discrepancies at the implant interface on 64 measurement points per area analyzed. Three-way ANOVA and Tukey tests were used to analyze the data (α = 0.05). RESULTS: The mean volumetric discrepancy values ranged from 0.8 to 3.1 µm among all the subgroups tested. The group (framework vs. implant) (p < 0.001) and tooth location (p < 0.001) were significant factors of the mean volumetric discrepancy values obtained. The framework group presented with significantly lower volumetric discrepancy mean values (1 µm) compared with the implant group (3 µm), whereas the premolar area obtained significantly lower mean volumetric discrepancy values (1.9 µm) compared with the molar location (2.3 µm). CONCLUSIONS: Volumetric discrepancies were found at the implant-framework interface tested between the pre- and post-artificial aging measurements ranging from 1 to 3 µm after 1,200,000 cyclic loading that simulated approximately 12 months of function.


Subject(s)
Dental Implants , Polymethyl Methacrylate , Titanium , Cobalt , Chromium , Dental Prosthesis, Implant-Supported , Chromium Alloys , Computer-Aided Design
19.
Arch Orthop Trauma Surg ; 144(1): 459-464, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37615684

ABSTRACT

INTRODUCTION: The role of different femoral head materials for total hip arthroplasty (THA) has been widely studied in the context of wear properties and corrosion. Cobalt chrome (CoCr) femoral heads are commonly used as a standard of comparison to other materials such as ceramic and oxidized zirconium (OxZi). This study aims to evaluate the impact of femoral head material on clinical outcomes in elective primary THA patients. METHODS: Retrospective analysis of THA patients within the Medicare claims database between October 2017 and September 2020 using diagnosis-related group codes was conducted. Information collected included sex, age, Charlson Comorbidity Index, and femoral head type. Patients with CoCr femoral heads were compared against patients with either OxZi or ceramic femoral heads using 1:1 propensity score matching. Z-testing and Chi-square analysis were used to determine between-group significance. RESULTS: In total, 112,960 elective THA patients were included, with 56,480 in OxZi or ceramic and 56,480 in CoCr. Readmission rates were lower in patients that received OxZi or ceramic femoral heads at 30-day (p < 0.0001), 60-day (p < 0.0001), and 90-day postoperatively (p < 0.0001) compared to CoCr. Mortality rates were also lower in patients that received OxZi or ceramic femoral heads at 30-day (p = 0.004), 60-day (p = 0.018), and 90-day postoperatively (p = 0.009) compared to CoCr. CONCLUSION: CoCr femoral heads had higher rates of readmissions and mortality compared to OxZi or ceramic. Further analysis of bearing surface combinations and sub-group analyses to determine significance between-group differences is needed. LEVEL III EVIDENCE: Retrospective analysis.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Aged , United States/epidemiology , Femur Head/surgery , Patient Readmission , Retrospective Studies , Time Factors , Prosthesis Design , Medicare , Chromium Alloys , Zirconium , Ceramics , Prosthesis Failure
20.
Odontology ; 112(2): 372-389, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37642767

ABSTRACT

This study aims at evaluating the effect of simulating porcelain firing on the microstructure, corrosion behavior and mechanical properties of a Co-Cr-Mo alloy fabricated by Metal Soft Milling (MSM). Two groups of Co-28Cr-5Mo specimens (25 × 20 × 3 mm) were prepared by MSM: The as-sintered (AS) specimens and the post-fired (PF) specimens that were subjected to 5 simulating porcelain firing cycles without applying the ceramic mass onto their surface. Phase identification by X-ray Diffraction (XRD), microstructure examination by optical microscopy and Scanning Electron Microscopy combined with Energy-Dispersive X-ray Spectroscopy (SEM/EDX), corrosion testing by cyclic polarization and chronoamperometry in simulated body fluid (SBF), the latter test accompanied by Cr3+ and Cr6+ detection in the electrolyte through the 1.5-diphenylcarbazide (DPC) method and UV/visible spectrophotometry, and mechanical testing by micro-/nano-indentation were conducted to evaluate the effect of the post-firing cycles on the properties of Co-Cr-Mo. The results were statistically analyzed by the t test (p < 0.05: statistically significant). All specimens had a mixed γ-fcc and ε-hcp cobalt-based microstructure with a dispersion of pores filled with SiO2 and a fine M23C6 intergranular presence. PF led to an increase in the ε-Co content and slight grain coarsening. Both AS and PF alloys showed high resistance to general and localized corrosion, whereas neither Cr6+ nor Cr3+ were detected during the passivity-breakdown stage. PF improved the mechanical properties of the AS-alloy, especially the indentation modulus and true hardness (statistically significant differences: p = 0.0009 and 0.006, respectively). MSM and MSM/simulating-porcelain firing have been proven trustworthy fabrication methods of Co-Cr-Mo substrates for metal-ceramic prostheses. Moreover, the post-firing cycles improve the mechanical behavior of Co-Cr-Mo, which is vital under the dynamically changing loads in the oral cavity, whereas they do not degrade the corrosion performance.


Subject(s)
Chromium Alloys , Metal Ceramic Alloys , Chromium Alloys/chemistry , Metal Ceramic Alloys/chemistry , Dental Porcelain/chemistry , Corrosion , Silicon Dioxide , Surface Properties , Materials Testing