Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23.671
Filter
1.
Mikrochim Acta ; 191(7): 365, 2024 06 04.
Article in English | MEDLINE | ID: mdl-38831060

ABSTRACT

Copper-cobalt bimetallic nitrogen-doped carbon-based nanoenzymatic materials (CuCo@NC) were synthesized using a one-step pyrolysis process. A three-channel colorimetric sensor array was constructed for the detection of seven antioxidants, including cysteine (Cys), uric acid (UA), tea polyphenols (TP), lysine (Lys), ascorbic acid (AA), glutathione (GSH), and dopamine (DA). CuCo@NC with peroxidase activity was used to catalyze the oxidation of TMB by H2O2 at three different ratios of metal sites. The ability of various antioxidants to reduce the oxidation products of TMB (ox TMB) varied, leading to distinct absorbance changes. Linear discriminant analysis (LDA) results showed that the sensor array was capable of detecting seven antioxidants in buffer and serum samples. It could successfully discriminate antioxidants with a minimum concentration of 10 nM. Thus, multifunctional sensor arrays based on CuCo@NC bimetallic nanoenzymes not only offer a promising strategy for identifying various antioxidants but also expand their applications in medical diagnostics and environmental analysis of food.


Subject(s)
Antioxidants , Carbon , Colorimetry , Copper , Nitrogen , Nitrogen/chemistry , Colorimetry/methods , Carbon/chemistry , Antioxidants/chemistry , Antioxidants/analysis , Copper/chemistry , Cobalt/chemistry , Hydrogen Peroxide/chemistry , Humans , Catalysis , Limit of Detection , Glutathione/chemistry , Glutathione/blood , Dopamine/blood , Dopamine/analysis , Dopamine/chemistry , Benzidines/chemistry , Polyphenols/chemistry , Polyphenols/analysis , Ascorbic Acid/chemistry , Ascorbic Acid/blood , Ascorbic Acid/analysis , Oxidation-Reduction , Uric Acid/blood , Uric Acid/chemistry , Uric Acid/analysis , Cysteine/chemistry , Cysteine/blood
2.
Anal Chim Acta ; 1312: 342742, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834261

ABSTRACT

Hyperuricemia (HUA) has gradually become a public health burden as an independent risk factor for a variety of chronic diseases. Herein, a user-friendly point-of-care (POC) detection system (namely "Smart-HUA-Monitor") based on smartphone-assisted paper-based microfluidic is proposed for colorimetric quantification of HUA urinary markers, including uric acid (UA), creatinine (CR) and pH. The detection limits of UA and CR were 0.0178 and 0.5983 mM, respectively, and the sensitivity of pH were 0.1. The method was successfully validated in artificial urine samples and 100 clinical samples. Bland-Altman plots showed a high consistency between µPAD and the testing instruments (HITACHI 7600 Automatic Analyzer, URIT-500B Urine Analyzer and AU5800B automatic biochemical analyzer) in hospital. Smart-HUA-Monitor provides an accurate quantitative, rapid, low-cost and reliable tool for the monitoring and early diagnosis of HUA urine indicators.


Subject(s)
Colorimetry , Hyperuricemia , Paper , Polymers , Uric Acid , Humans , Hyperuricemia/diagnosis , Hyperuricemia/urine , Polymers/chemistry , Uric Acid/urine , Colorimetry/instrumentation , Lab-On-A-Chip Devices , Smartphone , Creatinine/urine , Microfluidic Analytical Techniques/instrumentation , Limit of Detection , Biomarkers/urine , Hydrogen-Ion Concentration
3.
Anal Chim Acta ; 1312: 342721, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834258

ABSTRACT

This study reports a fast and visual detection method of antidepressant sertraline (SRT) drug by the core-shell AuNPs@CDs as the nanoprobes. The CDs has been eco-friendly synthesized from sweet lemon wastes to directly reduce Au+ to AuNPs without any external photoirradiation process or additional reductants. Optimizing key variables that impact the sensing process has been done using the central composite design (CCD) approach to simulate the assay condition before the analysis. Adding SRT with different concentrations to the nanoprobes under mildly acidic conditions presents an absorbance peak at 560 nm with purple color tonalities that differ from the behavior of alone nanoprobes (530 nm, pink color). The obtained absorption change is linearly proportional to the increase of SRT concentration from 1 µM to 35 µM with a limit of detection (LOD) value of 100 nM. The color changes with a vivid tonality from pink and purple to violet as the colorful fingerprint patterns are readily traceable by the naked eye, allowing the visual assay of SRT. The greenness of the developed approach is well evaluated by some international indexes including the complimentary green analytical procedure (ComplexGAPI) and also, the analytical greenness (AGREE) indexes. The proposed waste-derived nanoprobes based on the eco-friendly procedure not only conduct quantitative and qualitative non-invasive analysis of SRT by the naked eye but also, may widen for other applications in various fields.


Subject(s)
Cadmium Compounds , Gold , Metal Nanoparticles , Sertraline , Sulfides , Gold/chemistry , Metal Nanoparticles/chemistry , Sertraline/analysis , Sertraline/chemistry , Sulfides/chemistry , Cadmium Compounds/chemistry , Citrus/chemistry , Colorimetry/methods , Limit of Detection , Antidepressive Agents/analysis
4.
Anal Chim Acta ; 1312: 342764, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834269

ABSTRACT

BACKGROUND: Osteopontin (OPN) is closely associated with tumorigenesis, growth, invasion, and immune escape and it serves as a plasma biomarker for hepatocellular carcinoma (HCC). Nevertheless, the accurate and rapid detection of low-abundance OPN still poses significant challenges. Currently, the majority of protein detection methods rely heavily on large precision instruments or involve complex procedures. Therefore, developing a simple, enzyme-free, rapid colorimetric analysis method with high sensitivity is imperative. RESULTS: In this study, we have developed a portable colorimetric biosensor by integrating the triple-helix aptamer probe (THAP) and catalytic hairpin assembly (CHA) strategy, named as T-CHA. After binding to the OPN, the trigger probe can be released from THAP, then initiates the CHA reaction and outputs the signal through the formation of a G-quadruplex/Hemin DNAzyme with horseradish peroxidase-like activity. Consequently, this colorimetric sensor achieves visual free-labeled detection without additional fluorophore modification and allows for accurate quantification by measuring the optical density of the solution at 650 nm. Under optimal conditions, the logarithmic values of various OPN concentrations exhibit satisfactory linearity in the range of 5 pg mL-1 to 5 ng mL-1, with a detection limit of 2.04 pg mL-1. Compared with the widely used ELISA strategy, the proposed T-CHA strategy is rapid (∼105 min), highly sensitive, and cost-effective. SIGNIFICANCE: The T-CHA strategy, leveraging the low background leakage of THAP and the high catalytic efficiency of CHA, has been successfully applied to the detection of OPN in plasma, demonstrating significant promise for the early diagnosis of HCC in point-of-care testing. Given the programmability of DNA and the universality of T-CHA, it can be readily modified for analyzing other useful tumor biomarkers.


Subject(s)
Aptamers, Nucleotide , Colorimetry , Osteopontin , Colorimetry/methods , Aptamers, Nucleotide/chemistry , Humans , Osteopontin/blood , Osteopontin/chemistry , Osteopontin/analysis , Biosensing Techniques/methods , DNA, Catalytic/chemistry , DNA, Catalytic/metabolism , Limit of Detection , G-Quadruplexes
5.
Mikrochim Acta ; 191(7): 368, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38833176

ABSTRACT

A colorimetric analysis platform has been successfully developed based on FeCo-NC dual-atom nanozyme (FeCo-NC DAzyme) for the detection of organophosphorus pesticides (OPPs). The FeCo-NC DAzyme exhibited exceptional oxidase-like activity (OXD), enabling the catalysis of colorless TMB to form blue oxidized TMB (oxTMB) without the need for H2O2 involvement. By combining acid phosphatase (ACP) hydrolase with FeCo-NC DAzyme, a "FeCo-NC DAzyme + TMB + ACP + SAP" colorimetric system was constructed, which facilitated the rapid detection of malathion. The chromogenic system was applied to detect malathion using a smartphone-based app and an auxiliary imaging interferogram device for colorimetric measurements, which have a linear range of 0.05-4.0 µM and a limit of detection (LOD) as low as 15 nM in real samples, comparable to UV-Vis and HPLC-DAD detection methods. Overall, these findings present a novel approach for convenient, rapid, and on-site monitoring of OPPs.


Subject(s)
Colorimetry , Limit of Detection , Pesticides , Smartphone , Colorimetry/methods , Pesticides/analysis , Organophosphorus Compounds/analysis , Organophosphorus Compounds/chemistry , Malathion/analysis , Malathion/chemistry , Oxidoreductases/chemistry , Iron/chemistry , Acid Phosphatase/analysis , Acid Phosphatase/chemistry , Benzidines
6.
Oper Dent ; 49(3): 336-344, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38807319

ABSTRACT

OBJECTIVE: Tooth color matching is challenging, and digital photocolorimetry using eLABor_aid (eLAB) provides objective evaluation through polarized photographs. However, its comparability with spectrophotometry remains unclear. METHODS AND MATERIALS: Bovine incisor root canals (n=30) were prepared to simulate an incomplete root apex. The teeth were randomly assigned to three groups based on intracanal medication: control (without medication); calcium hydroxide/propylene glycol; and triple-antibiotic paste (n=10 each). Tooth color was assessed using both eLAB and spectrophotometry. Measurements were taken at the crown medio-cervical region on five-time intervals (baseline, 1, 3, 7, and 14 days). Statistical analysis included two-way repeated-measures ANOVA, Sidak post hoc and Pearson's correlation test (α=0.05). RESULTS: No significant differences were observed between the two methods for either medication or follow-ups (p>0.05). Triple-antibiotic paste exhibited higher color variation (p<0.05). After 7 days, all groups presented significant color changes (p<0.05). Moderate to high correlations (R2 from 0.51 to 0.84, p<0.0001) were found between both methods for all groups at all intervals. CONCLUSION: The eLAB is a reliable method for detecting tooth color changes, and its results are comparable to spectrophotometry analysis.


Subject(s)
Colorimetry , Spectrophotometry , Cattle , Animals , Spectrophotometry/methods , Colorimetry/methods , Anti-Bacterial Agents , Color , In Vitro Techniques , Calcium Hydroxide , Incisor/anatomy & histology , Propylene Glycol , Tooth Discoloration , Root Canal Irrigants/therapeutic use , Metronidazole/therapeutic use , Ciprofloxacin/therapeutic use , Dental Pulp Cavity/anatomy & histology
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 317: 124392, 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-38704997

ABSTRACT

Nanozyme-based colorimetric sensing has drawn immense attention due to the rapid development of nanozyme in recent years. However, the selectivity of nanozyme-based colorimetric sensing greatly limits its subsequent practical application. It is well known that sample pretreatment can not only improve selectivity by eliminating the sample matrix interference, but also improve sensitivity by enriching trace targets. Based on the easy facile surface modification properties of nanozyme, we rationally designed nanozyme combined with sample pretreatment for colorimetric biosensing, through separation and enrichment, thereby improving the selectivity and sensitivity of the nanozyme colorimetric biosensing. As a proof of concept, the detection of Hg2+ by nanozyme-based colorimetric sensing was used as an example. Magnetic peroxidase-like nanozyme Fe3S4 was designed and synthesized. The selectivity is improved by the specific adsorption of S-Hg bond and the interference elimination after magnetic separation. In addition, the sensitivity is improved by magnetic solid-phase extraction enrichment. Our established colorimetric sensing based on Fe3S4 nanozyme integrated sample pretreatment with an enrichment factor of 100 and the limit of detection (LOD) is 26 nM. In addition, this strategy was successfully applied to detect Hg2+ in environmental water samples. Overall, the strategy showed good selectivity and sensitivity, providing a new practical method for the application of nanozyme-based biosensing in sample pretreatment.


Subject(s)
Colorimetry , Limit of Detection , Mercury , Metal-Organic Frameworks , Solid Phase Extraction , Mercury/analysis , Mercury/isolation & purification , Colorimetry/methods , Solid Phase Extraction/methods , Metal-Organic Frameworks/chemistry , Catalysis , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/isolation & purification , Peroxidase/chemistry , Biosensing Techniques/methods
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 317: 124385, 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-38714005

ABSTRACT

A novel colorimetric-fluorescent dual-mode chemosensor (JT5) based on rhodamine B has been produced for monitoring Sn4+ in the DMSO/H2O (4:1, v/v) medium. It has high sensitivity, a low detection limit, a short response time (1 s) and high stability, and can still be maintained after two weeks with the red dual fluorescence/ colorimetric response. Enhancement of red fluorescence (591 nm) and red colorimetric (567 nm) response of JT5 by Sn4+ addition. The electrostatic potential of the sensor JT5 molecule was simulated to speculate on the sensing mechanism, and the IR, mass spectrometry and 1H NMR titration were utilized to further demonstrate that JT5 was coordinated to Sn4+ with a 1:1 type, the rhodamine spironolactam ring of JT5 opens up to form a penta-membered ring with Sn4+, meanwhile, its system may have chelation enhanced fluorescence (CHEF) effect. In addition, theoretical calculations were carried out to give the energy gaps of JT5 and [JT5 + Sn4+] as well as to simulate the electronic properties of the maximal absorption peaks. Notably, the sensor JT5 was successfully applied to monitoring Sn4+ in zebrafish, and the JT5-loaded filter paper provided a solid-state platform for detecting Sn4+ by both naked eye and fluorescent methods. In summary, this work contributes to monitoring Sn4+ in organisms and solid-state materials and promotes understanding of Sn4+ functions in biological systems, environments, and solid-state materials.


Subject(s)
Biosensing Techniques , Fluorescent Dyes , Rhodamines , Spectrometry, Fluorescence , Zebrafish , Rhodamines/chemistry , Animals , Fluorescent Dyes/chemistry , Biosensing Techniques/methods , Water/chemistry , Colorimetry/methods , Limit of Detection
9.
Anal Methods ; 16(21): 3372-3384, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38747244

ABSTRACT

Microfluidic channels fabricated over fabrics or papers have the potential to find substantial application in the next generation of wearable healthcare monitoring systems. The present work focuses on the fabrication procedures that can be used to obtain practically realizable fabric-based microfluidic channels (µFADs) utilizing patterning masks and wax, unlike conventional printing techniques. In this study, comparative analysis was used to differentiate channels obtained using different masking tools for channel patterning as well as different wax materials as hydrophobic barriers. Drawbacks of the conventional tape and candle wax technique were noted and a novel approach was used to create microfluidic channels through a facile and simple masking technique using PVC clear sheets as channel stencils and beeswax as the channel barriers. The resulting fabric based microfluidic channels with varying widths as well as complex microchannel, microwell, and micromixer designs were investigated and a minimum channel width resolution of 500 µm was successfully obtained over cotton based fabrics. Thereafter, the PVC clear sheet-beeswax based microwells were successfully tested to confine various organic and inorganic samples indicating vivid applicability of the technique. Finally, the microwells were used to make a simple and facile colorimetric assay for glucose detection and demonstrated effective detection of glucose levels from 10 mM to 50 mM with significant color variation using potassium iodide as the coloring agent. The above findings clearly suggest the potential of this alternative technique for making low-cost and practically realizable fabric based diagnostic devices (µFADs) in contrast to the other approaches that are currently in use.


Subject(s)
Polyvinyl Chloride , Textiles , Waxes , Waxes/chemistry , Polyvinyl Chloride/chemistry , Colorimetry/methods , Colorimetry/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Cost-Benefit Analysis , Glucose/analysis , Lab-On-A-Chip Devices , Humans , Equipment Design , Wearable Electronic Devices
10.
Mikrochim Acta ; 191(6): 339, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789855

ABSTRACT

Loop-mediated isothermal amplification (LAMP) is a molecular diagnosis technology with the advantages of isothermal reaction conditions and high sensitivity. However, the LAMP reactions are prone to producing false-positive results and thus are usually less reliable. This study demonstrates a gold nanoparticle (AuNP)-assisted colorimetric LAMP technique for diagnosing SARS-CoV-2, which aims to overcome the false-positive results. The AuNPs were functionalized with E gene probes, specifically tailored to bind to the amplified E-gene LAMP product, using the freezing method. Varied salt concentration and AuNP/probe combinations were tested for the highest visual performance. The experiments were conducted on synthetic SARS-CoV-2 RNA (Omicron variant), as well as on clinical samples. The assay showed an exceptional sensitivity of 8.05 fg of LAMP amplicon mixture (0.537 fg/µL). The average reaction time was ~ 30 min. In conclusion, AuNP-assisted LAMP detection will not identify any potential unspecific amplification, which helps to improve the efficiency and reliability of LAMP assays in point-of-care applications. The freezing method to functionalize the AuNPs with probes simplifies the assay, which can be utilized in further diagnostic studies.


Subject(s)
COVID-19 , Colorimetry , Gold , Metal Nanoparticles , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Gold/chemistry , Metal Nanoparticles/chemistry , Colorimetry/methods , Nucleic Acid Amplification Techniques/methods , SARS-CoV-2/genetics , Humans , COVID-19/diagnosis , COVID-19/virology , RNA, Viral/genetics , RNA, Viral/analysis , Freezing , Molecular Diagnostic Techniques/methods , Limit of Detection
11.
Sci Rep ; 14(1): 12125, 2024 05 27.
Article in English | MEDLINE | ID: mdl-38802360

ABSTRACT

Emergence of Coronavirus disease 2019 (COVID-19) pandemic has posed a huge threat to public health. Rapid and reliable test to diagnose infected subjects is crucial for disease spread control. We developed a colorimetric test for COVID-19 detection using a Colorimetric Assay based on thiol-linked RNA modified gold nanoparticles (AuNPs) and oligonucleotide probes. This method was conducted on RNA from 200 pharyngeal swab samples initially tested by Real-Time polymerase chain reaction (RT-PCR) as gold standard. A specific oligonucleotide probe designed based on ORF1ab of COVID-19 was functionalized with AuNPs-probe conjugate. The exposure of AuNP-probe to isolated RNA samples was tested using hybridization. In this comparative study, the colorimetric functionalized AuNPs assay exhibited a detection limit of 25 copies/µL. It was higher in comparison to the RT-PCR method, which could only detect 15 copies/µL. The results demonstrated 100% specificity and 96% sensitivity for the developed method. Herein, we developed an incredibly rapid, simple and cost-effective Colorimetric Assay lasting approximately 30 min which could process considerably higher number of COVID-19 samples compared to the RT-PCR. This AuNP-probe conjugate colorimetric method could be considered the optimum alternatives for conventional diagnostic tools especially in over-populated and/or low-income countries.


Subject(s)
COVID-19 , Colorimetry , Gold , Metal Nanoparticles , Nasopharynx , RNA, Viral , SARS-CoV-2 , Sensitivity and Specificity , Colorimetry/methods , Humans , COVID-19/diagnosis , COVID-19/virology , Metal Nanoparticles/chemistry , Gold/chemistry , Nasopharynx/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , RNA, Viral/analysis , RNA, Viral/genetics , RNA, Viral/isolation & purification , Limit of Detection , Oligonucleotide Probes/genetics , COVID-19 Nucleic Acid Testing/methods , Real-Time Polymerase Chain Reaction/methods , COVID-19 Testing/methods
12.
Anal Chim Acta ; 1306: 342586, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38692787

ABSTRACT

BACKGROUND: Early prostatic cancer (PCa) diagnosis significantly improves the chances of successful treatment and enhances patient survival rates. Traditional enzyme cascade-based early cancer detection methods offer efficiency and signal amplification but are limited by cost, complexity, and enzyme dependency, affecting stability and practicality. Meanwhile, sarcosine (Sar) is commonly considered a biomarker for PCa development. It is essential to develop a Sar detection method based on cascade reactions, which should be efficient, low skill requirement, and suitable for on-site testing. RESULTS: To address this, our study introduces the synthesis of organic-inorganic self-assembled nanoflowers to optimize existing detection methods. The Sar oxidase (SOX)-inorganic hybrid nanoflowers (Cu3(PO4)2:Ce@SOX) possess inherent fluorescent properties and excellent peroxidase activity, coupled with efficient enzyme loading. Based on this, we have developed a dual-mode multi-enzyme cascade nanoplatform combining fluorescence and colorimetric methods for the detection of Sar. The encapsulation yield of Cu3(PO4)2:Ce@SOX reaches 84.5 %, exhibiting a remarkable enhancement in catalytic activity by 1.26-1.29 fold compared to free SOX. The present study employing a dual-signal mechanism encompasses 'turn-off' fluorescence signals ranging from 0.5 µM to 60 µM, with a detection limit of 0.226 µM, and 'turn-on' colorimetric signals ranging from 0.18 µM to 60 µM, with a detection limit of 0.120 µM. SIGNIFICANCE: Furthermore, our study developed an intelligent smartphone sensor system utilizing cotton swabs for real-time analysis of Sar without additional instruments. The nano-platform exhibits exceptional repeatability and stability, rendering it well-suited for detecting Sar in authentic human urine samples. This innovation allows for immediate analysis, offering valuable insights for portable and efficient biosensors applicable to Sar and other analytes.


Subject(s)
Colorimetry , Oxidation-Reduction , Sarcosine , Smartphone , Sarcosine/urine , Sarcosine/analysis , Sarcosine/chemistry , Humans , Nanostructures/chemistry , Limit of Detection , Spectrometry, Fluorescence , Prostatic Neoplasms/diagnosis , Fluorescence , Biosensing Techniques , Sarcosine Oxidase/chemistry
13.
Anal Chim Acta ; 1306: 342599, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38692792

ABSTRACT

BACKGROUND: Microcystin-leucine-arginine (MC-LR) produced by various cyanobacteria during harmful algal bloom poses serious threats to drinking water safety and human health. Conventional chromatography-based detection methods require expensive instruments and complicated sample pretreatment, limiting their application for on-site detection. Colorimetric aptasensors are simple and rapid, and are amenable to fast detection. However, they provide only one output signal, resulting in poor sensitivity and accuracy. Dual-channel ratiometric colorimetric method based on the peroxidase-like activity of nanozyme can achieve self-calibration by recording two reverse signals, providing significantly enhanced sensitivity and accuracy. RESULTS: CeO2 nanocages (CeO2 NCs) with tetra-enzyme mimetic activities (oxidase-, peroxidase-, catalase- and superoxide dismutase-like activities) were facilely synthesized using zeolitic imidazolate framework-67 (ZIF-67) as sacrificial template. The peroxidase-like activity of CeO2 NCs can be regulated by DNA, and it showed opposite response to two chromogenic substrates (2,2'-azino-bis-(3-ethylbenzthiazoline-6-sulfonic acid) (ABTS) and 3,3',5,5'-tetramethylbenzidine (TMB)), which was mainly attributed to the changed affinity. On the basis of MC-LR aptamer-tunable peroxidase-like activity of CeO2 NCs in TMB and ABTS channel, a dual-channel ratiometric colorimetric aptasensor was constructed for detection of MC-LR. Compared with conventional single-signal colorimetric assays, the proposed method showed lower limit of detection (0.66 pg mL-1) and significantly enhanced sensitivity. Moreover, the practicability of the ratiometric colorimetric assay was demonstrated by detecting MC-LR in real water samples, and satisfactory recoveries (94.9-101.9 %) and low relative standard deviations (1.6-6.3 %) were obtained. SIGNIFICANCE: This work presents a nanozyme-based ratiometric colorimetric aptasensor for MC-LR detection by recording the reverse responses of two chromogenic reactions. Benefiting from the self-calibration function, the method can achieve higher sensitivity and accuracy. The short detection time and practical application in real water samples show great potential for environmental monitoring.


Subject(s)
Cerium , Colorimetry , Marine Toxins , Microcystins , Microcystins/analysis , Colorimetry/methods , Marine Toxins/analysis , Cerium/chemistry , Aptamers, Nucleotide/chemistry , Limit of Detection , Nanostructures/chemistry , Biosensing Techniques/methods
14.
Anal Chim Acta ; 1306: 342617, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38692789

ABSTRACT

BACKGROUND: Alpha-fetoprotein (AFP) is a fetal protein that can indicate congenital anomalies such as Down syndrome and spinal canal blockage when detected at abnormal levels in pregnant women. Current AFP detection methods rely on invasive blood or serum samples, which require sophisticated equipment. From the many solutions proposed, colorimetric paper-based assays excel in point-of-care settings. The concept of paper-based ELISA (p-ELISA) enhances traditional methods, aligning with the ASSURED criteria for diagnostics in resource-limited regions. Despite success in microfluidic paper-based assay devices, laser printing remains underexplored for p-ELISA. Additionally, modifying the paper surface provides an additional layer of sensitivity enhancement. RESULTS: In this study, we developed a novel laser-printed paper-based ELISA (LP-pELISA) for rapid, sensitive, and noninvasive detection of AFP in saliva samples. The LP-pELISA platform was fabricated by printing hydrophobic barriers on filter paper using a laser printer, followed by depositing hydroxyapatite (HAp) as an immobilization material for the antibodies. The colorimetric detection was achieved using AuNPs functionalized with anti-AFP antibodies and silver nitrate enhancement. The LP-pELISA exhibited a linear response for AFP detection in both buffer and saliva samples over a range of 1.0-800 ng mL-1, with a limit of detection (LOD) reaching 1.0 ng mL-1. The assay also demonstrated good selectivity, repeatability, reproducibility, and stability. The LP-pELISA was further validated by testing spiked human saliva samples, showing its potential for point-of-care diagnosis of congenital disabilities. SIGNIFICANCE: The LP-pELISA is a noninvasive platform showcasing simplicity, cost-effectiveness, and user-friendliness, utilizing laser printing, hydroxyapatite modification, and saliva samples to efficiently detect AFP. Beyond its application for AFP, this method's versatility extends to other biomarkers, positioning it as a catalyst for the evolution of paper-based biosensors. The LP-pELISA holds promise as a transformative tool for point-of-care diagnostics, fostering advancements in healthcare with its innovative technology.


Subject(s)
Colorimetry , Durapatite , Enzyme-Linked Immunosorbent Assay , Lasers , Paper , Saliva , alpha-Fetoproteins , Humans , Saliva/chemistry , Durapatite/chemistry , alpha-Fetoproteins/analysis , Printing , Gold/chemistry , Limit of Detection , Antibodies, Immobilized/immunology , Antibodies, Immobilized/chemistry
15.
Anal Chim Acta ; 1306: 342598, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38692791

ABSTRACT

BACKGROUND: Carbon-based nanozymes have recently received enormous concern, however, there is still a huge challenge for inexpensive and large-scale synthesis of magnetic carbon-based "Two-in-One" mimics with both peroxidase (POD)-like and laccase-like activities, especially their potential applications in multi-mode sensing of antibiotics and neurotransmitters in biofluids. Although some progresses have been made in this field, the feasibility of biomass-derived carbon materials with both POD-like and laccase-like activities by polyatomic doping strategy is still unclear. In addition, multi-mode sensing platform can provide a more reliable result because of the self-validation, self-correction and mutual agreement. Nevertheless, the use of magnetic carbon-based nanozyme sensors for the multi-mode detection of antibiotics and neurotransmitters have not been investigated. RESULTS: We herein report a shrimp shell-derived N, O-codoped porous carbon confined magnetic CuFe2O4 nanosphere with outstanding laccase-like and POD-like activities for triple-mode sensing of antibiotic d-penicillamine (D-PA) and chloramphenicol (CPL), as well as colorimetric detection of neurotransmitters in biofluids. The magnetic CuFe2O4/N, O-codoped porous carbon (MCNPC) armored mimetics was successfully fabricated using a combined in-situ coordination and high-temperature crystallization method. The synthesized MCNPC composite with superior POD-like activity can be used for colorimetric/temperature/smartphone-based triple-mode detection of D-PA and CPL in goat serum. Importantly, the MCNPC nanozyme can also be used for colorimetric analysis of dopamine and epinephrine in human urine. SIGNIFICANCE: This work not only offered a novel strategy to large-scale, cheap synthesize magnetic carbon-based "Two-in-One" armored mimetics, but also established the highly sensitive and selective platforms for triple-mode monitoring D-PA and CPL, as well as colorimetric analysis of neurotransmitters in biofluids without any tanglesome sample pretreatment.


Subject(s)
Anti-Bacterial Agents , Carbon , Copper , Neurotransmitter Agents , Carbon/chemistry , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/urine , Anti-Bacterial Agents/blood , Neurotransmitter Agents/urine , Neurotransmitter Agents/analysis , Neurotransmitter Agents/blood , Porosity , Copper/chemistry , Humans , Nanospheres/chemistry , Colorimetry/methods , Ferric Compounds/chemistry , Biomimetic Materials/chemistry , Animals , Biosensing Techniques/methods , Chloramphenicol/analysis , Chloramphenicol/urine , Limit of Detection
16.
Mikrochim Acta ; 191(6): 331, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38744722

ABSTRACT

A broad host range phage-based nanozyme (Fe-MOF@SalmpYZU47) was prepared for colorimetric detection of multiple Salmonella enterica strains. The isolation of a broad host range phage (SalmpYZU47) capable of infecting multiple S. enterica strains was achieved. Then, it was directly immobilized onto the Fe-MOF to prepare Fe-MOF@SalmpYZU47, exhibiting peroxidase-like activity. The peroxidase-like activity can be specifically inhibited by multiple S. enterica strains, benefiting from the broad host range capture ability of Fe-MOF@SalmpYZU47. Based on it, a colorimetric detection approach was developed for S. enterica in the range from 1.0 × 102 to 1.0 × 108 CFU mL-1, achieving a low limit of detection (LOD) of 11 CFU mL-1. The Fe-MOF@SalmpYZU47 was utilized for detecting S. enterica in authentic food samples, achieving recoveries ranging from 91.88 to 105.34%. Hence, our proposed broad host range phage-based nanozyme exhibits significant potential for application in the colorimetric detection of pathogenic bacteria.


Subject(s)
Colorimetry , Limit of Detection , Metal-Organic Frameworks , Salmonella enterica , Colorimetry/methods , Salmonella enterica/isolation & purification , Salmonella enterica/chemistry , Metal-Organic Frameworks/chemistry , Food Microbiology/methods , Food Contamination/analysis , Peroxidase/chemistry
17.
Braz Oral Res ; 38: e032, 2024.
Article in English | MEDLINE | ID: mdl-38747819

ABSTRACT

This study assessed the reliability of a color measurement method using images obtained from a charge-coupled device (CCD) camera and a stereoscopic loupe. Disc-shaped specimens were created using the composite Filtek Z350 XT (shades DA1, DA2, DA3, and DA4) (n = 3). CIELAB color coordinates of the specimens were measured using the spectrophotometer SP60 over white and black backgrounds. Images of the same specimens were taken using a CCD camera attached to a stereoscopic loupe. The color of the image was measured (red-green-blue [RGB]) using an image processing software and converted to CIELAB coordinates. For each color coordinate, data from images were adjusted using linear regressions predicting those values from SP60. The whiteness index for dentistry (WID) and translucency parameter (TP00) of the specimens as well as the color differences (ΔE00) among pairwise shades were calculated. Data were analyzed via repeated-measures analysis of variance and Tukey's post hoc test (α = 0.05). Images obtained using the loupe tended to be darker and redder than the actual color. Data adjustment resulted in similar WID, ΔE00, and TP00 values to those observed for the spectrophotometer. Differences were observed only for the WID of shade DA3 and ΔE00 for comparing DA1 and DA3 over the black background. However, these differences were not clinically relevant. The use of adjusted data from images taken using a stereoscopic loupe is considered a feasible method for color measurement.


Subject(s)
Color , Colorimetry , Composite Resins , Materials Testing , Spectrophotometry , Reproducibility of Results , Composite Resins/chemistry , Spectrophotometry/methods , Colorimetry/methods , Colorimetry/instrumentation , Analysis of Variance , Reference Values , Linear Models , Image Processing, Computer-Assisted/methods
18.
Methods Mol Biol ; 2804: 195-206, 2024.
Article in English | MEDLINE | ID: mdl-38753149

ABSTRACT

Clinical diagnostics of infectious diseases via nucleic acid amplification tests (NAATs) depend on a separate step of isolation of nucleic acids from cells/viruses embedded in complex biological matrices. The most recent example has been reverse transcription polymerase chain reaction (RT-PCR) for amplification and detection of SARS-CoV-2 RNA for COVID-19 diagnostics. Kits for RNA extraction and purification are commercially available; however, their integration with amplification systems is generally lacking, resulting in two separate steps, i.e., sample preparation and amplification. This makes NAATs more time-consuming, requiring skilled personnel, and can increase the likelihood of contamination. Here, we describe a setup and methodology to perform the quick extraction and detection of nucleic acids in an integrated manner. In particular, we focus on the use of an immiscible filtration device for capture, isolation, concentration, amplification, and colorimetric detection of SARS-CoV-2 RNA.


Subject(s)
COVID-19 , Filtration , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , RNA, Viral/isolation & purification , RNA, Viral/analysis , RNA, Viral/genetics , Humans , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Nucleic Acid Amplification Techniques/methods , Nucleic Acid Amplification Techniques/instrumentation , COVID-19/diagnosis , COVID-19/virology , Filtration/instrumentation , Filtration/methods , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/instrumentation , Colorimetry/methods , Colorimetry/instrumentation
19.
Molecules ; 29(9)2024 May 03.
Article in English | MEDLINE | ID: mdl-38731608

ABSTRACT

In this paper, Cu-BTC derived mesoporous CuS nanomaterial (m-CuS) was synthesized via a two-step process involving carbonization and sulfidation of Cu-BTC for colorimetric glutathione detection. The Cu-BTC was constructed by 1,3,5-benzenetri-carboxylic acid (H3BTC) and Cu2+ ions. The obtained m-CuS showed a large specific surface area (55.751 m2/g), pore volume (0.153 cm3/g), and pore diameter (15.380 nm). In addition, the synthesized m-CuS exhibited high peroxidase-like activity and could catalyze oxidation of the colorless substrate 3,3',5,5'-tetramethylbenzidine to a blue product. Peroxidase-like activity mechanism studies using terephthalic acid as a fluorescent probe proved that m-CuS assists H2O2 decomposition to reactive oxygen species, which are responsible for TMB oxidation. However, the catalytic activity of m-CuS for the oxidation of TMB by H2O2 could be potently inhibited in the presence of glutathione. Based on this phenomenon, the colorimetric detection of glutathione was demonstrated with good selectivity and high sensitivity. The linear range was 1-20 µM and 20-300 µM with a detection limit of 0.1 µM. The m-CuS showing good stability and robust peroxidase catalytic activity was applied for the detection of glutathione in human urine samples.


Subject(s)
Colorimetry , Copper , Glutathione , Hydrogen Peroxide , Nanostructures , Glutathione/analysis , Glutathione/chemistry , Colorimetry/methods , Copper/chemistry , Nanostructures/chemistry , Catalysis , Hydrogen Peroxide/chemistry , Hydrogen Peroxide/analysis , Porosity , Oxidation-Reduction , Phthalic Acids/chemistry , Humans , Benzidines/chemistry , Limit of Detection
20.
Anal Chim Acta ; 1308: 342639, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38740452

ABSTRACT

BACKGROUND: Calcium and magnesium ions are highly abundant and important cations in human body. At the same time, both dyscalcemia and dysmagnesemia are frequently encountered in the clinical practice. As deficiency or excess of Ca(II) or Mg(II) can cause severe symptoms, determining these ions in serum is of great importance. Concentration of these ions in biological samples is typically assayed in clinical laboratories with the use of expensive and specialized equipment. Since those methods cannot be easily adapted for self-diagnosis purposes, there is a great need to develop a convenient tool for reliable determination of calcium and magnesium in serum at the point-of-care. RESULTS: The colorimetric methods employed for calcium and magnesium analysis were o-cresophtalein complexone assay and xylidyl blue assay, respectively. Analytical signal acquisition was accomplished using an ordinary flatbed scanner or smartphone and free software. For increased user-friendliness the device was optimized to perform simultaneous determination of calcium and magnesium ions in only 10 min. In the optimized conditions, the limit of detection for calcium ions was 0.09 mmol L-1, while for magnesium it was 0.04 mmol L-1. Determination of both ions requires only 4 µL of serum sample. The developed paper-based sensors were validated with control human serum samples and the obtained relative errors for majority of samples were below 20 %. SIGNIFICANCE: In this paper, a microfluidic paper-based analytical device for simultaneous determination of calcium and magnesium ions in human serum is reported for the first time. Additionally, this is also the first report on colorimetric determination in serum of any of these ions in paper-based format. Simultaneous detection of both ions allows for fast and user-friendly screening of disturbance in calcium and magnesium homeostasis.


Subject(s)
Calcium , Magnesium , Paper , Magnesium/blood , Humans , Calcium/blood , Colorimetry , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/instrumentation , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL
...