Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.459
Filter
1.
Article in English | MEDLINE | ID: mdl-38780368

ABSTRACT

Pleuroperitoneal communication occurs when ascites moves from the abdominal cavity to the pleural cavity via a diaphragmatic fistula. Managing large pleural fluid volumes is challenging, often requiring an operation. Identifying small diaphragmatic fistulas during the operation can be problematic, but ensuring their detection improves outcomes. This video tutorial presents a recent empirical case in which we successfully identified and closed a pleuroperitoneal contact using a thoracoscopic surgical procedure aided by indocyanine green fluorescence imaging. The patient, a 66-year-old woman, was hospitalized due to acute dyspnoea from a right thoracic pleural effusion during hepatic ascites treatment for cirrhosis. Because ascites decreased with pleural fluid drainage, surgical intervention was considered due to suspicion of a pleuroperitoneal connection. During the operation, indocyanine green was injected intraperitoneally, and near-infrared fluorescence-guided thoracoscopy pinpointed the location of the diaphragmatic fistula. The fistula was sutured and reinforced with a polyglycolic acid sheet and fibrin glue. Detecting the fistula intraoperatively is crucial to prevent recurrence, and the indocyanine green fluorescence method is a safe and effective technique for detecting small fistulas.


Subject(s)
Indocyanine Green , Humans , Indocyanine Green/administration & dosage , Female , Aged , Ascites/diagnosis , Ascites/etiology , Ascites/surgery , Peritoneal Diseases/diagnosis , Peritoneal Diseases/surgery , Pleural Diseases/diagnosis , Pleural Diseases/surgery , Fistula/diagnosis , Fistula/surgery , Coloring Agents/administration & dosage , Pleural Effusion/diagnosis , Pleural Effusion/etiology , Pleural Effusion/surgery , Thoracoscopy/methods , Diaphragm/surgery
4.
J Cataract Refract Surg ; 50(5): 498-504, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38651697

ABSTRACT

PURPOSE: To compare 3 capsulotomy centration methods. SETTING: Private clinic, Zlin, Czech Republic. DESIGN: Prospective, consecutive case series. METHODS: 180 eyes undergoing cataract surgery had anterior capsule staining with microfiltered 0.4% trypan blue solution before selective laser capsulotomy. The first 60 eyes (Group 1) had mydriatic dilated pupil centered capsulotomies. The next 60 eyes (Group 2) were centered on the trypan blue central landmark (TCL). The final 60 capsulotomies (Group 3) were centered on the patient fixated coaxial Purkinje reflex (CPR). Measurements between key anatomical landmarks and the TCL, CPR capsulotomies, and implanted intraocular lens (IOL) center were made. RESULTS: The TCL, observed in >94% of eyes in the study, coincided with the CPR with a displacement of <0.1 ± 0.1 mm. Group 1 capsulotomies were noticeably decentered on the IOLs by 0.3 ± 0.2 mm. The Group 2 symmetrical IOL relationship was maintained with a decentration of 0.15 ± 0.1 mm. Group 3 had a similar decentration with the IOLs with 0.15 ± 0.1 mm. Verification with IOLMaster 700 data and CALLISTO Eye System showed that the CPR and the TCL were coincident with the measured visual axis. CONCLUSIONS: The clearly visible TCL served as an alternate landmark to the patient fixated CPR, and being on the anterior capsule was not sensitive to tilt. Further patient compliance was not required. Both were superior to dilated pupil centration, to achieve symmetric IOL coverage. This has application for both capsulotomies and capsulorhexes.


Subject(s)
Capsulorhexis , Coloring Agents , Phacoemulsification , Trypan Blue , Humans , Capsulorhexis/methods , Prospective Studies , Aged , Coloring Agents/administration & dosage , Lens Implantation, Intraocular , Male , Female , Middle Aged , Anterior Capsule of the Lens/surgery , Anatomic Landmarks , Lens Capsule, Crystalline/surgery , Aged, 80 and over
5.
Jpn J Ophthalmol ; 68(3): 211-215, 2024 May.
Article in English | MEDLINE | ID: mdl-38609716

ABSTRACT

PURPOSE: To investigate the association between the arm-to-choroidal circulation time (ACT) on indocyanine green angiography (IA) and clinical profile in patients with polypoidal choroidal vasculopathy (PCV). STUDY DESIGN: Single-center retrospective study. METHODS: We included 38 eyes of 38 patients with PCV diagnosed using multimodal imaging and did not undergo previous treatment. All patients were treated with monthly aflibercept injections for 3 months and treat-and-extend regimens for the subsequent 12 months. Posterior vortex vein ACT was assessed on the first visit using Heidelberg IA. The patients were divided into two groups: ACT ≥20 s (L group; eight eyes) and ACT <20 s (S group; 30 eyes). The clinical profiles before and after treatment were analyzed to assess associations with ACT. RESULTS: The mean ACT was 16.39±3.3 s (L group: 21.25±1.49 s, women:men=2:6, mean age: 77.3±6.5 years; S group: 15.10±2.17 s, women:men=7:23, mean age: 75.5±6.9 years). No significant difference was observed in the mean subfoveal choroidal thickness between the L and the S groups (176±75 µm vs. 230±79 µm, P=0.10). However, there were significant differences between the L and S groups in retinal fluid accumulation and hemorrhage recurrence (eight/eight eyes, 100% vs. 13/30 eyes, 43%, P<0.001), mean aflibercept injections (8.8±1.6 vs. 7.0±1.6, P<0.01) during the 12-month period, and the number of polypoidal lesions (1.8±0.7 vs. 1.3±0.5, P<0.05). CONCLUSION: Patients with PCV and ACT >20 s are more likely to experience exudative change recurrence in the retina during treatment because they have more polypoidal lesions.


Subject(s)
Choroid , Fluorescein Angiography , Fundus Oculi , Intravitreal Injections , Polyps , Receptors, Vascular Endothelial Growth Factor , Recombinant Fusion Proteins , Tomography, Optical Coherence , Visual Acuity , Humans , Female , Male , Retrospective Studies , Choroid/blood supply , Choroid/diagnostic imaging , Aged , Fluorescein Angiography/methods , Tomography, Optical Coherence/methods , Polyps/diagnosis , Polyps/drug therapy , Polyps/physiopathology , Receptors, Vascular Endothelial Growth Factor/therapeutic use , Receptors, Vascular Endothelial Growth Factor/administration & dosage , Recombinant Fusion Proteins/administration & dosage , Recombinant Fusion Proteins/therapeutic use , Indocyanine Green/administration & dosage , Follow-Up Studies , Choroidal Neovascularization/drug therapy , Choroidal Neovascularization/diagnosis , Choroidal Neovascularization/physiopathology , Coloring Agents/administration & dosage , Aged, 80 and over , Choroid Diseases/diagnosis , Choroid Diseases/drug therapy , Choroid Diseases/physiopathology , Angiogenesis Inhibitors/administration & dosage , Angiogenesis Inhibitors/therapeutic use , Regional Blood Flow/physiology , Multimodal Imaging , Blood Flow Velocity/physiology , Polypoidal Choroidal Vasculopathy
6.
J Neonatal Perinatal Med ; 17(2): 247-254, 2024.
Article in English | MEDLINE | ID: mdl-38640176

ABSTRACT

BACKGROUND: The prognosis of congenital chylothorax and ascites ranges from spontaneous resolution to death, but no established examination exists to predict the prognosis. We aimed to develop a clinically useful method to evaluate lymphatic abnormalities using indocyanine green (ICG) lymphography in infants with congenital chylothorax and ascites. METHODS: We retrospectively evaluated infants with congenital chylothorax and chylous ascites who underwent ICG lymphography in our hospital between 2012 and 2022. The ICG lymphography findings was evaluated. We defined the dermal backflow in the trunk as the lymphatic flow from the end of the limb back through the lymphatic vessels on the surface of the trunk. The association between the dermal backflow in the trunk and clinical outcomes, as follows, are investigated: the duration of the drainage period, the duration of endotracheal intubation, and the length of hospital stay. RESULTS: Twenty infants had a dermal backflow in the trunk, and ten did not. Clinical outcomes in infants with and without dermal backflow in the trunk were as follows (median): the duration of the drainage period (20 vs. 0 days, p = 0.001), the duration of endotracheal intubation (12 vs. 2 days, p = 0.04), and the length of hospital stay (62 vs. 41 days, p = 0.04), respectively. In multivariate linear regression analysis adjusted for gestational age, the duration of the drainage period was correlated with the dermal backflow in the trunk [exp(B) = 2.62; p = 0.003]. CONCLUSIONS: The dermal backflow in the trunk in ICG lymphography was useful in predicting the clinical course of congenital chylothorax and ascites.


Subject(s)
Chylothorax , Chylous Ascites , Indocyanine Green , Lymphography , Humans , Lymphography/methods , Chylous Ascites/diagnostic imaging , Chylous Ascites/congenital , Chylous Ascites/therapy , Male , Chylothorax/congenital , Chylothorax/diagnostic imaging , Chylothorax/therapy , Female , Retrospective Studies , Infant, Newborn , Length of Stay/statistics & numerical data , Prognosis , Infant , Intubation, Intratracheal/methods , Coloring Agents/administration & dosage
7.
Updates Surg ; 76(3): 1105-1108, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38639875

ABSTRACT

HCA resection is crucial to prevent bleeding and malignant transformation. The aim of this study was to enhance the precision of tumor resection in hepatocellular adenoma (HCA) through the combination of intraoperative ultrasound (IOUS) and indocyanine green (ICG) fluorescence imaging. ICG was intravenously injected 24 h before surgery, enabling positive staining of HCA nodules. IOUS guided the parenchymal transection performed using the RoboLap approach. IOUS combined with ICG effectively demarcated lesions, allowing precision surgery while sparing healthy liver tissue. Intraoperative frozen examination further validated the potential of ICG to identify previously undetected lesions. The study showed promising advantages of ICG in HCA resections, potentially reducing the risk of recurrence and malignant transformation. The combined robotic and laparoscopic approach improved the feasibility of parenchymal-sparing surgery, offering a cautious assessment of HCA lesions.


Subject(s)
Indocyanine Green , Liver Neoplasms , Robotic Surgical Procedures , Indocyanine Green/administration & dosage , Humans , Robotic Surgical Procedures/methods , Liver Neoplasms/surgery , Hepatectomy/methods , Adenoma, Liver Cell/surgery , Adenoma, Liver Cell/diagnostic imaging , Middle Aged , Female , Male , Laparoscopy/methods , Coloring Agents/administration & dosage , Optical Imaging/methods , Surgery, Computer-Assisted/methods
9.
Ann Surg Oncol ; 31(6): 4019-4021, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38480563

ABSTRACT

BACKGROUND: Currently, an effective tracer technique for lymphatic drainage during laparoscopic surgery has not been established. This study aimed to elucidate a new fluorescence, imaging technique targeting the hepatic lymphatic drainage area, using indocyanine green (ICG). METHODS: A patient diagnosed with intrahepatic cholangiocarcinoma (ICC) located in segment 8 of the liver was injected with ICG into the connective tissue of the Glisson pedicle supplied by the lesion's liver segment, avoiding the bile duct, portal vein, and hepatic artery. This was performed under the guidance of laparoscopic ultrasonographic localization to trace the lymph nodes. RESULTS: The lymphatic drainage area traced intraoperatively by ICG was consistent with the definition of the right regional lymph nodes for ICC. The lymph nodes were dissected, followed by addition of a fluorescence tracer. CONCLUSIONS: Mastering intraoperative ultrasonic puncture technology can enable effective and accurate tracing of the lymph nodes of the liver segment where the lesion is located. However, the technical standards for this methodology need to be established through further studies.


Subject(s)
Bile Duct Neoplasms , Coloring Agents , Indocyanine Green , Laparoscopy , Humans , Indocyanine Green/administration & dosage , Laparoscopy/methods , Coloring Agents/administration & dosage , Bile Duct Neoplasms/surgery , Bile Duct Neoplasms/diagnostic imaging , Bile Duct Neoplasms/pathology , Cholangiocarcinoma/surgery , Cholangiocarcinoma/diagnostic imaging , Cholangiocarcinoma/pathology , Male , Lymph Nodes/surgery , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Liver Neoplasms/surgery , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Drainage/methods , Middle Aged , Prognosis , Lymph Node Excision/methods
10.
Int J Gynecol Cancer ; 34(5): 675-680, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38485222

ABSTRACT

BACKGROUND: Lymphatic involvement is the most important prognostic factor in early-stage cervical cancer. Sentinel lymph node biopsy is a viable alternative to systematic lymphadenectomy and may identify metastases more precisely. OBJECTIVE: To compare two tracers (indocyanine green and patent blue) to detect sentinel nodes. METHODS: A single-center, retrospective study of women treated due to early-stage cervical cancer (International Federation of Gynecology and Obstetrics 2009 IA1 with lymphovascular invasion, IA2, and IB1). Location and tracer of all detected sentinel nodes had been documented for a prospective, multicenter trial (SENTIX trial). All sentinel nodes were sent to frozen section and final analysis through ultrastaging using a standard protocol. RESULTS: Overall, 103 patients were included. Bilateral detection rate for indocyanine green (93.2%) was significantly higher than for blue dye (77.7%; p=0.004). Their combined use significantly increased the bilateral detection to 99.0% (p=0.031). While 97.4% of all sentinel nodes were located below the common iliac vessels, no para-aortic nodes were labeled. Simultaneous bilateral detection with both tracers was found in 71.8% of the cases, of which the sentinel nodes were identical in 91.9%. Nine positive nodes were detected among seven patients (6.8%), all marked with indocyanine green while patent blue labeled six. Frozen section failed to detect one of three macrometastases and three of four micrometastases (sensitivity 43%; negative prediction value 96%). CONCLUSION: Anatomical distribution and topographic localization of the sentinel nodes obtained with these tracers were not different. Indocyanine green provided a significantly higher bilateral detection rate and had superior sensitivity to detect positive nodes compared with patent blue. Combining indocyanine green and blue dye increased the bilateral detection rate significantly.


Subject(s)
Coloring Agents , Indocyanine Green , Neoplasm Staging , Rosaniline Dyes , Sentinel Lymph Node Biopsy , Uterine Cervical Neoplasms , Humans , Indocyanine Green/administration & dosage , Female , Sentinel Lymph Node Biopsy/methods , Uterine Cervical Neoplasms/pathology , Middle Aged , Retrospective Studies , Adult , Coloring Agents/administration & dosage , Aged , Sentinel Lymph Node/pathology , Sentinel Lymph Node/diagnostic imaging , Lymphatic Metastasis , Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/diagnostic imaging , Aged, 80 and over , Prognosis , Adenocarcinoma/pathology , Adenocarcinoma/diagnostic imaging
11.
Clin Neurol Neurosurg ; 240: 108241, 2024 05.
Article in English | MEDLINE | ID: mdl-38522224

ABSTRACT

BACKGROUND: Second Window Indocyanine Green (SWIG) is a novel intraoperative imaging technique that uses near-infrared (NIR) light for intra-operative tumor visualization using the well-known fluorophore indocyanine green (ICG). Because schwannomas often incorporate the nerve into the encapsulated tumor and impinge on surrounding neural structures, SWIG is a promising technique to improve tumor resection while sparing the nerve. OBJECTIVE: To demonstrate the use of SWIG in resection of cranial nerve schwannomas. METHODS: Three patients with cranial nerve schwannomas (i.e., trigeminal, vestibular, and vagus) underwent SWIG-guided resection. During surgery, NIR visualization was used intermittently used to detect fluorescence to guide resection. Signal-to-background ratio was then calculated to quantify fluorescence. RESULTS: Patients were infused with ICG at a dose of 5.0 mg/kg 24 hours before surgery. Each patient achieved total or near-total resection and relief of symptoms with lack of recurrence at six-month follow-up. The average SBR calculated was 3.79, comparable to values for SWIG-guided resection of other brain and spine tumors. CONCLUSION: This case series is the first published report of trigeminal and vagus nerve schwannoma resection using the SWIG technique and suggests that SWIG may be used to detect all schwannomas, alongside many other types of brain tumor. This paper also demonstrates the importance of preoperative ICG infusion timing and discusses the inverse pattern of NIR signal that may be observed when infusion occurs outside of the optimal timing. This provides direction for future studies investigating the administration of SWIG to resect cranial nerve schwannomas and other brain tumors.


Subject(s)
Cranial Nerve Neoplasms , Indocyanine Green , Neurilemmoma , Humans , Indocyanine Green/administration & dosage , Neurilemmoma/surgery , Neurilemmoma/diagnostic imaging , Cranial Nerve Neoplasms/surgery , Cranial Nerve Neoplasms/diagnostic imaging , Female , Middle Aged , Male , Adult , Neurosurgical Procedures/methods , Coloring Agents/administration & dosage
12.
Updates Surg ; 76(3): 1063-1071, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38507176

ABSTRACT

Preserving the integrity of parathyroid glands is crucial in papillary thyroid cancer (PTC) surgery to avoid hypoparathyroidism. In recent years, two novel dyes, activated carbon nanoparticles (CNP) and indocyanine green (ICG), have been utilized to assist in parathyroid gland identification. However, the use of CNP or ICG alone can result in extravasation of dye or excessive fluorescence of non-parathyroid tissue, which can affect the accuracy of surgical outcomes by yielding false negative or false positive results. Therefore, it is important to further optimize the application of these two dyes in surgery. We analyzed case files of 124 PTC patients who underwent routine total or near-total thyroidectomy with bilateral lymph node dissection in the central region at the Affiliated People's Hospital of Ningbo University from January to November 2022. The patients were randomly divided into three groups based on the type of intraoperative dye used. The CNP group (n = 38) received an intra-thyroidal injection of CNP dye. The ICG group (n = 42) used the ICG near-infrared fluorescence endoscopy system to show parathyroid fluorescence. The group that received a combined approach of ICG and CNP (n = 44) leveraged the advantages of both methods that allow for positive development of ICG and negative development of CNP to identify and preserve the parathyroid gland during operation. The parathyroid hormone detection reagent (PTH test method) was employed to verify the highly suspected parathyroid tissue in all three groups. We analyzed intraoperative data pertaining to intraoperative parathyroid identification, misexcision, number of autotransplantation, and postoperative hypoparathyroidism among the three groups. Compared with the ICG group and the CNP group, the combined group demonstrated more prominent advantages in identifying average the number of lower parathyroid glands (1.93 ± 0.26, p = 0.015), reducing the average numberrate of misexcision (0.45 ± 0.5, p = 0.004), and reducing the incidence of postoperative temporary hypothyroidism (3/44, p = 0.015). The combined use of ICG and CNP dual-dye with PTH test method appears to be more effective in both identifying and protecting parathyroid glands during PTC surgery.


Subject(s)
Carbon , Coloring Agents , Indocyanine Green , Nanoparticles , Parathyroid Glands , Parathyroid Hormone , Thyroid Cancer, Papillary , Thyroid Neoplasms , Thyroidectomy , Humans , Indocyanine Green/administration & dosage , Parathyroid Glands/diagnostic imaging , Parathyroid Glands/surgery , Retrospective Studies , Thyroid Cancer, Papillary/surgery , Carbon/administration & dosage , Thyroidectomy/methods , Thyroid Neoplasms/surgery , Female , Male , Middle Aged , Parathyroid Hormone/blood , Coloring Agents/administration & dosage , Adult , Hypoparathyroidism/prevention & control , Hypoparathyroidism/etiology , Cohort Studies , Lymph Node Excision/methods
13.
Int J Urol ; 31(6): 646-652, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38426591

ABSTRACT

INTRODUCTION: Use of indocyanine green (ICG) with near-infrared fluorescence (NIRF) has been demonstrated to be an effective tool for intraoperative assessment of bowel and ureteric vascularity. This study aimed to evaluate the impact of ICG on postsurgical outcomes such as anastomotic bowel leak and uretero-enteric stricture formation during robot-assisted cystectomy (RAC) and intracorporeal urinary diversion (ICUD). METHODS: We identified 238 patients who underwent RAC at the University of Louisville between September 2012 and August 2021. Patients were divided into two groups based on the utilization of ICG. Demographic, perioperative outcomes, and rate of anastomotic bowel leak were compared. RESULTS: In total, 138 patients were in the ICG group and 100 patients were in the non-ICG group. More intracorporeal urinary diversions and more simple cystectomies were observed in the ICG group (p < 0.001 and p = 0.015, respectively). The ICG group patients initiated an oral diet sooner than the control group (4.9 vs. 7.1 days, p < 0.001). The mean length of stay of the ICG group was shorter than the non-ICG group (8.3 vs. 12.8 days, p < 0.001). The rate of postoperative ileus was not significantly different between cohorts. No patients in the ICG group experienced a bowel leak compared with five patients in the non-ICG group (p = 0.008). CONCLUSIONS: In our study, the use of ICG for intraoperative assessment of bowel and ureteric vascularity was associated with earlier bowel recovery and a shorter length of stay. It was also significantly correlated with a lower rate of anastomotic bowel leak.


Subject(s)
Cystectomy , Indocyanine Green , Robotic Surgical Procedures , Urinary Diversion , Humans , Indocyanine Green/administration & dosage , Cystectomy/adverse effects , Cystectomy/methods , Urinary Diversion/methods , Urinary Diversion/adverse effects , Male , Robotic Surgical Procedures/adverse effects , Robotic Surgical Procedures/methods , Female , Middle Aged , Aged , Retrospective Studies , Anastomotic Leak/etiology , Anastomotic Leak/epidemiology , Anastomotic Leak/prevention & control , Urinary Bladder Neoplasms/surgery , Length of Stay/statistics & numerical data , Treatment Outcome , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Coloring Agents/administration & dosage
14.
Ann Surg ; 279(6): 923-931, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38375670

ABSTRACT

OBJECTIVE: To assess the effectiveness of indocyanine green (ICG)-guided lymph node (LN) dissection during laparoscopic radical gastrectomy after neoadjuvant chemotherapy (NAC) in patients with locally advanced gastric cancer (LAGC). BACKGROUND: Studies on ICG imaging use in patients with LAGC on NAC are rare. METHODS: Patients with gastric adenocarcinoma (clinical T2-4NanyM0) who received NAC were randomly assigned to receive ICG-guided laparoscopic radical gastrectomy or laparoscopic radical gastrectomy alone. Here, we reported the secondary endpoints including the quality of lymphadenectomy (total retrieved LNs and LN noncompliance) and surgical outcomes. RESULTS: Overall, 240 patients were randomized. Of whom, 236 patients were included in the primary analysis (118 in the ICG group and 118 in the non-ICG group). In the ICG group, the mean number of LNs retrieved was significantly higher than in the non-ICG group within the D2 dissection (48.2 vs 38.3, P < 0.001). The ICG fluorescence guidance significantly decreased the LN noncompliance rates (33.9% vs 55.1%, P = 0.001). In 165 patients without baseline measurable LNs, ICG significantly increased the number of retrieved LNs and decreased the LN noncompliance rate ( P < 0.05). For 71 patients with baseline measurable LNs, the quality of lymphadenectomy significantly improved in those who had a complete response ( P < 0.05) but not in those who did not ( P > 0.05). Surgical outcomes were comparable between the groups ( P > 0.05). CONCLUSIONS: ICG can effectively improve the quality of lymphadenectomy in patients with LAGC who underwent laparoscopic radical gastrectomy after NAC.


Subject(s)
Adenocarcinoma , Gastrectomy , Indocyanine Green , Laparoscopy , Lymph Node Excision , Neoadjuvant Therapy , Stomach Neoplasms , Humans , Indocyanine Green/administration & dosage , Stomach Neoplasms/surgery , Stomach Neoplasms/pathology , Stomach Neoplasms/drug therapy , Lymph Node Excision/methods , Male , Laparoscopy/methods , Female , Middle Aged , Gastrectomy/methods , Aged , Adenocarcinoma/surgery , Adenocarcinoma/drug therapy , Adenocarcinoma/pathology , Coloring Agents/administration & dosage , Adult , Treatment Outcome , Neoplasm Staging , Chemotherapy, Adjuvant
15.
Dis Colon Rectum ; 67(6): 850-859, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38408871

ABSTRACT

BACKGROUND: Left-sided colorectal surgery demonstrates high anastomotic leak rates, with tissue ischemia thought to influence outcomes. Indocyanine green is commonly used for perfusion assessment, but evidence remains mixed for whether it reduces colorectal anastomotic leaks. Laser speckle contrast imaging provides dye-free perfusion assessment in real-time through perfusion heat maps and quantification. OBJECTIVE: This study investigates the efficacy of advanced visualization (indocyanine green versus laser speckle contrast imaging), perfusion assessment, and utility of laser speckle perfusion quantification in determining ischemic margins. DESIGN: Prospective intervention group using advanced visualization with case-matched, retrospective control group. SETTINGS: Single academic medical center. PATIENTS: Forty adult patients undergoing elective, minimally invasive, left-sided colorectal surgery. INTERVENTIONS: Intraoperative perfusion assessment using white light imaging and advanced visualization at 3 time points: T1-proximal colon after devascularization, before transection, T2-proximal/distal colon before anastomosis, and T3-completed anastomosis. MAIN OUTCOME MEASURES: Intraoperative indication of ischemic line of demarcation before resection under each visualization method, surgical decision change using advanced visualization, post hoc laser speckle perfusion quantification of colorectal tissue, and 30-day postoperative outcomes. RESULTS: Advanced visualization changed surgical decision-making in 17.5% of cases. For cases in which surgeons changed a decision, the average discordance between the line of demarcation in white light imaging and advanced visualization was 3.7 cm, compared to 0.41 cm ( p = 0.01) for cases without decision changes. There was no statistical difference between the line of ischemic demarcation using laser speckle versus indocyanine green ( p = 0.16). Laser speckle quantified lower perfusion values for tissues beyond the line of ischemic demarcation while suggesting an additional 1 cm of perfused tissue beyond this line. One (2.5%) anastomotic leak occurred in the intervention group. LIMITATIONS: This study was not powered to detect differences in anastomotic leak rates. CONCLUSIONS: Advanced visualization using laser speckle and indocyanine green provides valuable perfusion information that impacts surgical decision-making in minimally invasive left-sided colorectal surgeries. See Video Abstract . UTILIDAD CLNICA DE LAS IMGENES DE CONTRASTE MOTEADO CON LSER Y LA CUANTIFICACIN EN TIEMPO REAL DE LA PERFUSIN INTESTINAL EN RESECCIONES COLORRECTALES DEL LADO IZQUIERDO MNIMAMENTE INVASIVAS: ANTECEDENTES:La cirugía colorrectal del lado izquierdo demuestra altas tasas de fuga anastomótica, y se cree que la isquemia tisular influye en los resultados. El verde de indocianina se utiliza habitualmente para evaluar la perfusión, pero la evidencia sobre si reduce las fugas anastomóticas colorrectales sigue siendo contradictoria. Las imágenes de contraste moteado con láser proporcionan una evaluación de la perfusión sin colorantes en tiempo real a través de mapas de calor de perfusión y cuantificación.OBJETIVO:Este estudio investiga la eficacia de la evaluación de la perfusión mediante visualización avanzada (verde de indocianina versus imágenes de contraste moteado con láser) y la utilidad de la cuantificación de la perfusión con moteado láser para determinar los márgenes isquémicos.DISEÑO:Grupo de intervención prospectivo que utiliza visualización avanzada con un grupo de control retrospectivo de casos emparejados.LUGARES:Centro médico académico único.PACIENTES:Cuarenta pacientes adultos sometidos a cirugía colorrectal electiva, mínimamente invasiva, del lado izquierdo.INTERVENCIONES:Evaluación de la perfusión intraoperatoria mediante imágenes con luz blanca y visualización avanzada en tres puntos temporales: T1-colon proximal después de la devascularización, antes de la transección; T2-colon proximal/distal antes de la anastomosis; y T3-anastomosis completa.PRINCIPALES MEDIDAS DE VALORACIÓN:Indicación intraoperatoria de la línea de demarcación isquémica antes de la resección bajo cada método de visualización, cambio de decisión quirúrgica mediante visualización avanzada, cuantificación post-hoc de la perfusión con láser moteado del tejido colorrectal y resultados posoperatorios a los 30 días.RESULTADOS:La visualización avanzada cambió la toma de decisiones quirúrgicas en el 17,5% de los casos. Para los casos en los que los cirujanos cambiaron una decisión, la discordancia promedio entre la línea de demarcación en las imágenes con luz blanca y la visualización avanzada fue de 3,7 cm, en comparación con 0,41 cm (p = 0,01) para los casos sin cambios de decisión. No hubo diferencias estadísticas entre la línea de demarcación isquémica utilizando láser moteado versus verde de indocianina (p = 0,16). El moteado con láser cuantificó valores de perfusión más bajos para los tejidos más allá de la línea de demarcación isquémica y al mismo tiempo sugirió 1 cm adicional de tejido perfundido más allá de esta línea. Se produjo una fuga anastomótica (2,5%) en el grupo de intervención.LIMITACIONES:Este estudio no tuvo el poder estadístico suficiente para detectar diferencias en las tasas de fuga anastomótica.CONCLUSIONES:La visualización avanzada utilizando moteado láser y verde de indocianina proporciona información valiosa sobre la perfusión que impacta la toma de decisiones quirúrgicas en cirugías colorrectales mínimamente invasivas del lado izquierdo. (Traducción-Dr. Ingrid Melo).


Subject(s)
Anastomotic Leak , Indocyanine Green , Laser Speckle Contrast Imaging , Humans , Female , Male , Indocyanine Green/administration & dosage , Middle Aged , Anastomotic Leak/prevention & control , Anastomotic Leak/diagnosis , Aged , Laser Speckle Contrast Imaging/methods , Minimally Invasive Surgical Procedures/methods , Coloring Agents/administration & dosage , Colon/blood supply , Colon/surgery , Colon/diagnostic imaging , Retrospective Studies , Colectomy/methods , Prospective Studies , Anastomosis, Surgical/methods , Ischemia/prevention & control , Ischemia/diagnosis , Case-Control Studies
16.
Eur J Ophthalmol ; 34(3): NP72-NP77, 2024 May.
Article in English | MEDLINE | ID: mdl-38311889

ABSTRACT

AIM: to provide a detailed description and multimodal imaging (MMI) including retro-mode imaging of acute posterior multifocal placoid pigment epitheliopathy (APMPPE). METHODS: Case report of a young male patient presenting with APMPPE picture. Initially, visual acuity testing was performed, followed by biomicroscopic and fundus examinations along with MMI including Optical Coherence Tomography (OCT), fundus autofluorescence (FAF), fluorescein angiography (FA), Indocyanine Green (ICG) angiography, and Retro-mode imaging. The patient was then monitored over a duration of two months. RESULTS: visual acuity was 20/20 with normal biomicroscopic examination; fundus examination detected multiple pale placoid lesions. MMI was consistent with typical APMPPE. Notably, Retro-mode imaging revealed numerous crater-like round lesions that corresponded to those observed on angiography. CONCLUSION: Retromode imaging in APMPPE can serve as a non-invasive tool that highlights the number and distribution of lesions as well as on angiography.


Subject(s)
Fluorescein Angiography , Indocyanine Green , Multimodal Imaging , Retinal Pigment Epithelium , Tomography, Optical Coherence , Visual Acuity , Humans , Male , Fluorescein Angiography/methods , Tomography, Optical Coherence/methods , Retinal Pigment Epithelium/pathology , Retinal Pigment Epithelium/diagnostic imaging , Acute Disease , Indocyanine Green/administration & dosage , Fundus Oculi , Coloring Agents/administration & dosage , Adult , Retinal Diseases/diagnosis , Retinal Diseases/diagnostic imaging
17.
Retina ; 44(6): 1083-1091, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38308567

ABSTRACT

PURPOSE: To investigate the imaging and clinical features of polypoidal choroidal vasculopathy (PCV) with pulsation. METHODS: The PCV eyes were classified into pulsatile and nonpulsatile PCV groups according to the pulsation on indocyanine green angiography. Imaging features including the dye filling time of the polyp and clinical features were compared. RESULTS: A total of 75 eyes were classified into the pulsatile PCV (30 eyes) and the nonpulsatile PCV (45 eyes) groups. The initial filling time and complete filling time of the polyp of the pulsatile PCV group (2.59 ± 0.93 and 8.33 ± 3.42 seconds) were shorter than those of the nonpulsatile PCV group (4.11 ± 1.87 and 10.63 ± 3.81 seconds, P < 0.001 and P = 0.010, respectively). The pigment epithelial detachment height of the pulsatile PCV group (414.90 ± 377.15 µ m) was greater than that of the nonpulsatile PCV group (247.81 ± 164.07 µ m, P = 0.030). The pulsatile PCV group showed a higher prevalence of subretinal hemorrhage (43.33%) after intravitreal injection than the nonpulsatile PCV group (13.95%, P = 0.005) during 12 months. The mean number of injections during 12 months of the pulsatile PCV group (5.48 ± 1.46) was greater than that of the nonpulsatile PCV group (4.09 ± 1.21, P < 0.001). CONCLUSION: Eyes with pulsatile PCV showed shorter filling time of the polyp, greater pigment epithelial detachment height, higher prevalence of subretinal hemorrhage, and more intravitreal injection numbers during 12 months. These might suggest that PCV has distinct imaging and clinical features according to the polyp pulsation.


Subject(s)
Choroid , Fluorescein Angiography , Polyps , Tomography, Optical Coherence , Humans , Female , Fluorescein Angiography/methods , Male , Aged , Polyps/diagnosis , Polyps/physiopathology , Choroid/blood supply , Tomography, Optical Coherence/methods , Retrospective Studies , Middle Aged , Visual Acuity/physiology , Fundus Oculi , Indocyanine Green/administration & dosage , Coloring Agents/administration & dosage , Choroid Diseases/diagnosis , Choroid Diseases/physiopathology , Choroidal Neovascularization/diagnosis , Choroidal Neovascularization/physiopathology , Choroidal Neovascularization/drug therapy , Aged, 80 and over , Intravitreal Injections , Polypoidal Choroidal Vasculopathy
18.
Int J Gynecol Cancer ; 34(6): 824-829, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38336372

ABSTRACT

OBJECTIVE: To evaluate the impact of different volumes of indocyanine green (ICG) on the detection rate and bilateral mapping of sentinel lymph nodes in patients with apparent uterine-confined endometrial cancer. METHODS: All patients who underwent surgical staging with sentinel node mapping in six reference centers were included. Two different protocols of ICG intracervical injection were used: (1) 2 mL group: total volume of 2 mL injected superficially; (2) 4 mL group: total volume of 4 mL, 2 mL deeply and 2 mL superficially. Logistic regression was used to analyze factors that could influence dye migration and detection rates. A sensitivity analysis was carried out to determine how independent variables could affect the sentinel node detection rate. RESULTS: Of 442 eligible patients, 352 were analyzed (172 in the 2 mL group and 180 in the 4 mL group). The bilateral detection rates of the 2 mL and 4 mL groups were 84.9% and 86.1%, respectively (p=0.76). The overall detection rate was higher with a volume of 4 mL than with 2 mL (97.8% vs 92.4%, respectively; p=0.024). In the univariate analysis the rate of bilateral mapping fell from 87.5% to 73.5% when the International Federation of Gynecology and Obstetrics (FIGO) 2009 tumor stage was >IB (p=0.018). In the multivariate analysis, for both overall and bilateral detection rates a statistically significant difference emerged for the volume of ICG injected and FIGO 2009 stage >IB. Increasing body mass index was associated with worse overall detection rates on univariate analysis (p=0.0006), and significantly decreased from 97% to 91% when the body mass index exceeded 30 kg/m2 (p=0.05). CONCLUSIONS: In patients with early-stage endometrial cancer, a volume of 2 mL ICG does not seem to compromise the bilateral detection of sentinel lymph nodes. In women with obesity and FIGO 2009 stage >IB, a 4 mL injection should be preferred.


Subject(s)
Coloring Agents , Endometrial Neoplasms , Indocyanine Green , Neoplasm Staging , Sentinel Lymph Node Biopsy , Sentinel Lymph Node , Humans , Female , Indocyanine Green/administration & dosage , Endometrial Neoplasms/pathology , Endometrial Neoplasms/surgery , Middle Aged , Sentinel Lymph Node/pathology , Sentinel Lymph Node/diagnostic imaging , Aged , Coloring Agents/administration & dosage , Sentinel Lymph Node Biopsy/methods , Adult , Aged, 80 and over , Lymphatic Metastasis
SELECTION OF CITATIONS
SEARCH DETAIL
...