Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.833
Filter
1.
Zhonghua Yan Ke Za Zhi ; 60(6): 541-546, 2024 Jun 11.
Article in Chinese | MEDLINE | ID: mdl-38825954

ABSTRACT

The increasing incidence of myopia has become a global public health concern. Exploring the mechanisms underlying the onset and progression of myopia is crucial for prevention and control. This paper reviews the role of peripheral retinal defocus mechanisms in the development of myopia, with particular emphasis on the interaction between accommodation lag and peripheral retinal defocus, as well as the impact of optical intervention on myopia control effectiveness. In recent years, researchers have developed various optical tools for myopia prevention and control based on the peripheral retinal defocus theory, such as peripheral defocus spectacle lenses, orthokeratology lenses, and peripheral defocus soft contact lenses. This paper aims to provide clinicians with the latest research findings to deepen their understanding of the mechanisms involved in myopia development and to guide the future development and clinical application of myopia prevention and control products.


Subject(s)
Disease Progression , Myopia , Retina , Humans , Myopia/therapy , Myopia/physiopathology , Accommodation, Ocular , Eyeglasses , Contact Lenses, Hydrophilic , Orthokeratologic Procedures/methods , Refraction, Ocular
2.
Invest Ophthalmol Vis Sci ; 65(5): 4, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38691089

ABSTRACT

Purpose: To investigate the adhesion of Acanthamoeba to scleral contact lens (ScCL) surface according to lens shape. Methods: Two strains of A. polyphaga (CDC:V062 and ATCC 30461) and one clinical Acanthamoeba isolate, were inoculated onto five contact lens (CL): one first-generation silicone hydrogel (SHCL; lotrafilcon B; adhesion control) containing plasma surface treatment; two ScCL (fluorosilicone acrylate) one containing surface treatment composed of plasma and the other containing plasma with Hydra-PEG, and two CL designed with a flat shape having the same material and surface treatments of the ScCL. Trophozoites that adhered to the lens's surfaces were counted by inverted optical light microscopy. Possible alterations of the lens surface that could predispose amoeba adhesion and Acanthamoeba attached to these lens surfaces were evaluated by scanning electron microscopy (SEM). Results: All strains revealed greater adhesion to the ScCL when compared with the flat lenses (P < 0.001). The clinical isolate and the ATCC 30461 had a higher adhesion (P < 0.001) when compared with the CDC:V062. A rough texture was observed on the surface of the lenses that have been examined by SEM. Also, SEM revealed that the isolates had a rounded appearance on the surface of the ScCL in contrast with an elongated appearance on the surface of the silicone hydrogel. Conclusions: The findings revealed that the curved shape of the ScCL favors amoeba adhesion.


Subject(s)
Acanthamoeba , Microscopy, Electron, Scanning , Acanthamoeba/physiology , Acanthamoeba/ultrastructure , Sclera , Humans , Contact Lenses, Hydrophilic/parasitology , Cell Adhesion/physiology , Contact Lenses/parasitology , Trophozoites/ultrastructure , Trophozoites/physiology , Hydrogels , Animals
3.
BMC Ophthalmol ; 24(1): 173, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627653

ABSTRACT

OBJECTIVES: This study aims to compare the efficacy of peripheral add multifocal soft contact lenses (SCLs) (excluding bifocal SCLs) with single vision contact lenses or spectacles in controlling myopia progression. METHOD: A comprehensive literature search was conducted in the Pubmed, EMBASE, Web of Science, and Cochrane Library databases until October 2023. The literature was thoroughly screened based on predetermined eligibility criteria. Pooled odds ratios (ORs) were calculated for dichotomous data and weighted mean differences (WMD) for continuous data. RESULTS: A total of 11 articles comprising 787 participants were included in this meta-analysis. Our pooled results demonstrated that the peripheral add multifocal SCLs groups exhibited significantly reduced refraction progression (MD = 0.20; 95%CI, 0.14 ∼ 0.27; P<0.001) and less axial length elongation (MD=-0.08; 95%CI, -0.09∼-0.08; P<0.001) compared to the control group. There was no significant difference in high-contrast logMAR distance visual acuity between the two groups (MD = 0.01; 95%CI, -0.00 ∼ 0.02; P = 0.19). However, the group using single-vision lenses had better low-contrast logMAR distance visual acuity compared to those using peripheral add multifocal SCLs (MD = 0.06; 95%CI, 0.02 ∼ 0.10; P = 0.004). Data synthesis using a random-effects model indicated an incidence of contact lens-related adverse events of 0.065 (95%CI, 0.048 ∼ 0.083). CONCLUSIONS: The present meta-analysis signifies that peripheral defocus modifying contact lenses are effective in slowing down the progression of myopia and reducing axial elongation.


Subject(s)
Contact Lenses, Hydrophilic , Myopia , Humans , Myopia/therapy , Visual Acuity , Contact Lenses, Hydrophilic/adverse effects , Refraction, Ocular , Vision Tests , Vision Disorders
4.
Lab Chip ; 24(8): 2327-2334, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38563256

ABSTRACT

The eyes provide rich physiological information and offer diagnostic potential as a sensing site, and probing tear constituents via the wearable contact lens could be explored for healthcare monitoring. Herein, we propose a novel adhesive contrast contact lens platform that can split tear film by natural means of tear secretion and blinking. The adhesive contrast is realized by selective grafting of a lubricant onto a polydimethylsiloxane (PDMS)-based contact lens, leading to high pinning zones on a non-adhesive background. The difference in contact angle hysteresis facilitates the liquid splitting. Further, the method offers control over the droplet volume by controlling the zone dimension. The adhesive contrast contact lens is coupled with fluorescent spectroscopic as well as colorimetric techniques to realize its potential as a diagnostic platform. The adhesive contrast contact lens is exploited to detect the level of lactoferrin in tear by sensitizing split droplets with Tb3+ ions. The adhesive contrast contact lens integrated with a fluorescence spectrometer was able to detect the lactoferrin level up to a concentration of 0.25 mg mL-1. Additionally, a colorimetric detection based on the fluorescence of the lactoferrin-terbium complex is demonstrated for the measurement of lactoferrin, with a limit of detection in the physiological range up to 0.5 mg mL-1.


Subject(s)
Contact Lenses, Hydrophilic , Lactoferrin/analysis , Eye , Tears/chemistry , Blinking
5.
Nat Commun ; 15(1): 2828, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38565532

ABSTRACT

Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called 'personalized lag time'. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.


Subject(s)
Contact Lenses, Hydrophilic , Diabetes Mellitus , Animals , Humans , Glucose/analysis , Blood Glucose , Tears/chemistry , Diabetes Mellitus/diagnosis
6.
Jpn J Ophthalmol ; 68(3): 225-232, 2024 May.
Article in English | MEDLINE | ID: mdl-38557918

ABSTRACT

PURPOSE: We aimed to compare the efficacy and safety of accelerated contact lens-assisted cross-linking (CA-CXL) with Lotrafilcon B and Comfilcon A lenses in keratoconus (KC) patients with thin corneas. STUDY DESIGN: Retrospective, single-center study. MATERIALS AND METHODS: We retrospectively included 51 eyes of 39 KC patients with corneal thickness <400µm after epithelial scraping (Epi-off), who underwent accelerated CA-CXL treatment with Lotrafilcon B (n=20) and Comfilcon A (n=31). Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest refraction values, corneal topographic data and endothelial cell density were recorded at preoperative and postoperative 1st, 3rd and 6th month controls. RESULTS: CDVA in the Comfilcon A group was higher than CDVA before surgery at 6 months postoperatively (p<0.001). When the two lenses were compared, CDVA was found to be significantly higher in the Lotrafilcon B group in the preoperative, postoperative 1st month and 3rd month values, but there was no significant difference between the postoperative 6th month values (p=0.028, p=0.018, p=0.044, p=0.181, respectively). The maximum keratometry (Kmax) value at the 6th month after surgery in the Comfilcon A group was significantly lower than in the Lotrafilcon B group (p=0,009). There was no significant difference between the endothelial cell density values between the groups (p=0.623, p=0.609, p=0.794, p=0.458, respectively). There was no significant difference between the progression, regression, and stability rates of the two groups (p=0.714). CONCLUSIONS: Accelerated CA-CXL with Lotrafilcon B and Comfilcon A silicone hydrogel lenses is a safe and effective method to stop progression in patients with thin corneas.


Subject(s)
Collagen , Corneal Topography , Cross-Linking Reagents , Keratoconus , Photochemotherapy , Photosensitizing Agents , Refraction, Ocular , Riboflavin , Visual Acuity , Humans , Keratoconus/diagnosis , Keratoconus/physiopathology , Keratoconus/drug therapy , Keratoconus/therapy , Keratoconus/metabolism , Female , Male , Retrospective Studies , Visual Acuity/physiology , Photosensitizing Agents/therapeutic use , Adult , Riboflavin/therapeutic use , Photochemotherapy/methods , Young Adult , Refraction, Ocular/physiology , Collagen/metabolism , Treatment Outcome , Cornea/pathology , Ultraviolet Rays , Follow-Up Studies , Adolescent , Cell Count , Corneal Stroma/metabolism , Endothelium, Corneal/pathology , Contact Lenses, Hydrophilic , Corneal Cross-Linking
7.
Cont Lens Anterior Eye ; 47(3): 102163, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38582614

ABSTRACT

PURPOSE: The main aim of this study was to evaluate the type, parameters, loss and complications of contact lenses (CLs) in the treatment of paediatric aphakia over a 10-year period. METHODS: This retrospective multicentre chart review included the files of aphakic CL wearers under the age of 9 years old that were treated between 2008 and 2018. Patients with traumatic aphakia and scarring of the cornea were excluded. The following data were collected; demographic data, cataract type (congenital or secondary), CL type, parameters and wearing time, reason for replacement and discontinuation of the CLs, visual acuity (VA), prophylactic use of antibiotics (ABs), and complications. RESULTS: Ninety-one aphakic children (132 eyes) were fitted with soft CLs. The median age of cataract extraction was 10.50 weeks (interquartile range (IQR) 7,15) in the congenital cataract group and 112 weeks (IQR 41,285) in the secondary cataract group. At the initial fitting a silicone elastomer CL was fitted in 86 % and a silicone hydrogel CL in 12 %, the remaining 2 % were mixed CL types. The median CL power at baseline was + 29 D (IQR 25,32) and after 3 years of wear the median power had shifted significantly to + 20 D (IQR 17,26), P < 0.001. A total of 1083 extra CL replacements were needed of which 414 in the first year of wear. Of these 414 replacements almost half (46 %;n = 191) were due to loss of the CL. Complications developed in 8 (9 %) cases and 7 (8 %) patients discontinued CL wear. CONCLUSION: This paper confirms that paediatric aphakia can be successfully treated with soft CLs with low rates of complications and discontinuation encountered. Unscheduled CL replacements due to loss are a concern, especially in the first year, and are straining for both the care giver and medical system. Attentive care and clear information is advised during the first year of CL wear.


Subject(s)
Visual Acuity , Humans , Retrospective Studies , Female , Male , Child, Preschool , Child , Visual Acuity/physiology , Infant , Netherlands/epidemiology , Contact Lenses, Hydrophilic , Aphakia, Postcataract/physiopathology , Cataract Extraction , Aphakia , Cataract/congenital
8.
Cont Lens Anterior Eye ; 47(3): 102166, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38604915

ABSTRACT

PURPOSE: To investigate the association between dryness, ocular surface temperature (OST), and conjunctival blood flow (CBF) in soft contact lens (SCL) wearers after airflow stimulation. METHODS: After recruiting 21 SCL wearers (mean age, 25.3 ± 4.2 years), subjects used two different daily disposable silicone hydrogel SCLs (narafilcon A and delefilcon A lenses). On three of four measurement days, excluding the first, OST, CBF, tear meniscus height (TMH), and non-invasive tear break-up time (NIBUT) were measured after airflow stimulation at a rate of 3 m/s for 10 min. The measurements were conducted without SCLs on the first and second days, and with different SCLs on the third and fourth days. Dryness was evaluated using the visual analogue scale (VAS). These parameters were compared between the two types of SCLs, and their association with the dryness sensation was then investigated. RESULTS: Dryness was significantly weakly correlated with OST (r = -0.375, p < 0.05) and CBF (r = 0.339, p < 0.05). TMH, NIBUT, and VAS scores for dryness with the delefilcon A lens (0.15 ± 0.05 mm, 3.7 ± 01.7 s and 29.4 ± 16.9) were significantly higher, longer, and lower, respectively, than those with the narafilcon A lens (0.12 ± 0.05 mm, 2.3 ± 1.7 s and 35.9 ± 17.0; p < 0.05, p < 0.01 and p < 0.01). The changes in the OST and CBF between with and without the delefilcon A lens (-0.36 ± 0.35 °C and 0.99 ± 0.19) were significantly small compared to the narafilcon A lens (-0.60 ± 0.42 °C and 1.11 ± 0.21; p < 0.01 for both comparisons). CONCLUSION: Dryness was correlated with OST and CBF, which indicates that when dryness was high, OST was low and CBF was high. These results suggest that OST and CBF assessments are effective for evaluating dryness sensation.


Subject(s)
Conjunctiva , Contact Lenses, Hydrophilic , Dry Eye Syndromes , Tears , Humans , Adult , Male , Female , Conjunctiva/blood supply , Conjunctiva/physiopathology , Tears/physiology , Dry Eye Syndromes/physiopathology , Dry Eye Syndromes/etiology , Young Adult , Body Temperature/physiology , Regional Blood Flow/physiology
9.
Sci Rep ; 14(1): 8592, 2024 04 13.
Article in English | MEDLINE | ID: mdl-38615153

ABSTRACT

Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs-several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCLs.


Subject(s)
Contact Lenses, Hydrophilic , Lizards , Presbyopia , Humans , Animals , Computer Simulation , Presbyopia/therapy , Visual Acuity
10.
Cont Lens Anterior Eye ; 47(3): 102160, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38570253

ABSTRACT

PURPOSE: To investigate the differences in contact lens sagittal depth (CL-SAG), base curve (BC), and overall lens diameter (OAD) of daily disposable (DD) SCLs at room temperature (20 °C) and on-eye (34 °C) temperature. METHODS: Twelve different spherical daily SCLs were analyzed (labeled power -3.00 D) at 20 °C and 34 °C. The posterior CL-SAG, BC, and OAD were measured directly using a spectral domain OCT-based instrument (Optimec is830). RESULTS: The CL-SAG range for the daily disposable lenses measured at 20 °C was 3468-4016 µm. At 34 °C, the DD CL-SAG of all lenses individually decreased compared to 20 °C (t = 7.78, p < 0.001), ranging from 3385 to 3913 µm. On average at the higher temperature, the measured overall lens diameter was smaller (t = 8.18, p < 0.001) and the BC was marginally steeper (t = 2.11, p = 0.058). CONCLUSIONS: Soft lens parameters change when equilibrated from room temperature (20 °C) to on-eye temperature (34 °C). All lenses shrink when going to on-eye temperature (both lens diameter and CL-SAG decreases), compared to lenses measured at room temperature by ISO standards. Higher water content materials tend to have greater changes to the lens parameters compared to lower water content material lenses.


Subject(s)
Contact Lenses, Hydrophilic , Disposable Equipment , Temperature , Humans , Tomography, Optical Coherence
11.
Optom Vis Sci ; 101(3): 134-142, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38546754

ABSTRACT

SIGNIFICANCE: The availability of a range of effective myopia control modalities enables the clinician to exercise judgment when discussing the treatment plan with the patient and their parents. This article outlines important considerations beyond efficacy.Clinically meaningful myopia control may be attained with some spectacle lenses, select soft contact lenses, some concentrations of atropine, and overnight orthokeratology. Given that satisfactory efficacy can be achieved with a range of modalities, other factors should be considered when deciding upon the best intervention for a given child. Four key factors-compliance, quality of vision, quality of life, and safety-are discussed in this review. Compliance directly impacts efficacy regardless of the modality and is the most important consideration, as it is influenced by quality of vision and comfort. Daily disposal myopia control contact lenses and overnight orthokeratology are generally associated with high compliance, provide better vision-related quality of life than spectacles, and carry a very low risk when used appropriately. A further benefit of overnight orthokeratology is the elimination of a need for optical correction during the day.


Subject(s)
Contact Lenses, Hydrophilic , Myopia , Child , Humans , Quality of Life , Myopia/therapy , Atropine , Exercise
12.
BMC Ophthalmol ; 24(1): 141, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38549070

ABSTRACT

PURPOSE: In the present study, we aimed to evaluate the efficacy of the bandage contact lens (BCLs) in the treatment of dry eye disease (DED) after complicated cataract or/and intraocular lens (IOL) surgery. METHODS: In this retrospective, single-centered, observational study, we collected data from 69 patients who underwent complicated cataract or/and IOL surgery. Of these, 35 cases wore their own BCLs immediately after the operation, while the other 34 cases did not have their own BCLs and were instead covered with gauze. The Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp microscope examination, keratograph analysis, and Schirmer I test were measured at baseline, 1 week and 1 month postoperatively. RESULTS: In the BCL group, the score of the OSDI questionnaire was significantly decreased at 1 week and 1 month postoperatively compared with baseline levels (P = 0.000, collectively). Moreover, the fluorescein staining score of the BCL group was remarkably decreased 1-week and 1-month postoperatively compared with the non-BCL group (P = 0.000 and P = 0.000, respectively). Furthermore, the redness score of the BCL group was also better compared with the non-BCL group at 1 week and 1 month postoperatively (P = 0.014 and P = 0.004, respectively). CONCLUSIONS: Complicated cataract or/and IOL surgery would intensify the DED. Early application of BCLs postoperatively improved patients' comfort and alleviated dry eye-related symptoms and signs. Furthermore, this mechanism might involve the acceleration of corneal epithelial healing, the alleviation of ocular stress response and the stabilization of the tear film. TRIAL REGISTRATION: Trial registration ClinicalTrials, NCT04120389. Registered 10 October 2019-retrospectively registered.


Subject(s)
Cataract , Contact Lenses, Hydrophilic , Dry Eye Syndromes , Lenses, Intraocular , Humans , Retrospective Studies , Lenses, Intraocular/adverse effects , Cataract/complications , Dry Eye Syndromes/etiology , Dry Eye Syndromes/diagnosis , Contact Lenses, Hydrophilic/adverse effects , Bandages/adverse effects
13.
PLoS One ; 19(3): e0296279, 2024.
Article in English | MEDLINE | ID: mdl-38507419

ABSTRACT

PURPOSE: To investigate trends in contact lens usage in a nationally representative sample of the Korean population in 2021. METHODS: For this retrospective study, we analyzed data of 3,601 Korean participants aged 10-59 years, from the Korea National Health and Nutrition Examination Survey (KNHANES 2021 version), who underwent eye examination, of whom 1,136 individuals (274 men and 862 women) were contact lens users. The demographic trend among Korean contact lens wearers was examined using statistical analyses to investigate the changes in their contact lens-wearing experience, duration of lens use, type of lens used, location of purchase, presence of an Eye Care Practitioner(ECP)'s prescription, lens-related ophthalmic complications, and type of lenses worn at the time of complications, according to sex. Multivariable logistic regression analysis was conducted to examine the association of each variable with the rate of complications and use of soft lenses. RESULTS: The average age of the contact lens users was 33.42±0.33 years, with 70.36% (weighted percentage) of users being women who used contact lenses for significantly longer periods than men (p<0.001). Additionally, only wearing of cosmetic lenses was significantly correlated with the occurrence of complications (p = 0.006), and 6.76% of users purchased lenses without a prescription. Multivariate analysis among the contact lens users revealed a significant relationship between the complication rate and female sex (p = 0.002), pre-existing eye disease diagnosed by ECPs (p = 0.0288), and duration of contact lens use (p<0.0001). CONCLUSION: We identified sex differences in contact lens usage trends in Korea. The main changes observed were an increase in middle-aged lens users and a decrease in female users compared to that in the early 2000s. In addition, contact lens complications were significantly associated with sex and pre-existing eye disease. Therefore, those wearing contact lenses for extended periods should exercise caution and consult eye care specialists in the presence of any symptoms.


Subject(s)
Contact Lenses, Hydrophilic , Contact Lenses , Eye Diseases , Middle Aged , Humans , Female , Male , Adult , Cohort Studies , Retrospective Studies , Nutrition Surveys , Contact Lenses/adverse effects , Research Design , Eye Diseases/diagnosis , Republic of Korea/epidemiology , Contact Lenses, Hydrophilic/adverse effects
14.
Ophthalmic Physiol Opt ; 44(4): 686-692, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38433496

ABSTRACT

PURPOSE: To determine the number of previous contact lens (CL) wearers who could be comfortably refitted into delefilcon A (DAILIES TOTAL1®) CLs. METHODS: This was a 6-month, three-visit study that recruited subjects who discontinued CLs within the past 2 years because of discomfort or dryness symptoms. Subjects were required to have Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire scores ≤3 and to be able to wear spherical study CLs. Subjects were asked to complete a ±50 comfort visual analogue scale (VAS) at 1 month and a Likert questionnaire after 1 and 6 months of CL wear to understand the subjects' CL experience. RESULTS: All 60 subjects who were fitted with the study CLs were still wearing them after 1 month, while one subject had dropped out by 6 months. Subjects had a median (interquartile range) age of 24.0 (7.0) years (71.7% female). They reported a median VAS score of 44.0 (8.0) units at the 1-month visit, with all reporting a comfortable score. At the 1-month/6-month visits, 98.3%/93.2%, 86.5%/78.0% and 93.2%/91.5% of subjects responded that they were very satisfied or satisfied with their vision, their end-of-day CL comfort and overall CL comfort, respectively. The same subjects responded that they were very likely or likely to continue to wear the study CLs at 1 (89.6%) and 6 months (80.7%) and to recommend the study CLs to a friend at 1 (98.3%) and 6 months (93.2%). CONCLUSIONS: The results suggest that when encountering a CL dropout, a practitioner could educate a patient about trying an alternative CL and consider delefilcon A lenses as an option.


Subject(s)
Disposable Equipment , Humans , Female , Male , Adult , Surveys and Questionnaires , Young Adult , Contact Lenses, Hydrophilic , Patient Satisfaction , Dry Eye Syndromes/physiopathology , Patient Dropouts , Adolescent
15.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38546401

ABSTRACT

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Subject(s)
Blinking , Contact Lenses, Hydrophilic , Tears , Humans , Contact Lenses, Hydrophilic/adverse effects , Male , Female , Adult , Tears/metabolism , Tears/physiology , Pilot Projects , Blinking/physiology , Young Adult , Osmolar Concentration , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Dry Eye Syndromes/physiopathology , Eyelids
16.
Ophthalmic Physiol Opt ; 44(4): 718-726, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38551074

ABSTRACT

PURPOSE: To compare the ocular effects of exposure to a low-humidity environment with and without contact lens (CL) wear using various non-invasive tests. METHODS: Fourteen habitual soft CL wearers were exposed to controlled low humidity (5% relative humidity [RH]) in an environmental chamber for 90 min on two separate occasions. First, when wearing their habitual spectacles and then, on a separate visit, when wearing silicone hydrogel CLs that were fitted specifically for this purpose. All participants had adapted to the new CL prior to data collection. Three non-invasive objective measurements were taken at each visit: blinking rate, objective ocular scatter (measured using the objective scatter index) and ocular surface cooling rate (measured using a long-wave infrared thermal camera). At each visit, measurements were taken before the exposure in comfortable environmental conditions (RH: 45%), and after exposure to environmental stress (low humidity, RH: 5%). RESULTS: CL wearers showed increased blinking rate (p < 0.005) and ocular scatter (p = 0.03) but similar cooling rate of the ocular surface (p = 0.08) when compared with spectacle wear in comfortable environmental conditions. The exposure to low humidity increased the blinking rate significantly with both types of corrections (p = 0.01). Interestingly, ocular scatter (p = 0.96) and cooling rate (p = 0.73) were not significantly different before and after exposure to low humidity. There were no significant two-way interactions between correction and exposure in any of the measurements. CONCLUSIONS: CLs significantly increased the blinking rate, which prevented a quick degradation of the tear film integrity as it was refreshed more regularly. It is hypothesised that the increased blinking rate in CL wearers aids in maintaining ocular scatter quality and cooling rate when exposed to a low-humidity environment. These results highlight the importance of blinking in maintaining tear film stability.


Subject(s)
Blinking , Humidity , Humans , Pilot Projects , Blinking/physiology , Adult , Male , Female , Young Adult , Contact Lenses, Hydrophilic , Tears/physiology , Contact Lenses
17.
Int Ophthalmol ; 44(1): 136, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38485796

ABSTRACT

BACKGROUND: The surface wettability of soft contact lenses (SCLs) affects the wearing comfort. Verofilcon A is a daily disposable silicone hydrogel contact lens with SMARTSURFACE® technology, ensuring high surface wettability. PURPOSE: To evaluate tear stability on the surface of verofilcon A and narafilcon A SCLs and correlate these findings with clinical parameters and patients' discomfort. METHODS: Sixty-two SCL wearers (124 eyes) with SCL discomfort were randomly assigned to use narafilcon A (control SCL) and verofilcon A for 2 weeks each by crossover. The noninvasive tear break-up time (NIBUT) of the naked eye at baseline and pre-lens NIBUT (PL-NIBUT) of the SCL surface after 2 weeks of using each SCL were measured using the DR-1α® dry eye observation device. Corneal superficial punctate keratopathy (SPK) (0-3) and conjunctival hyperemia (0-3), and comfort level of SCL wear (1-10) were also evaluated. RESULTS: NIBUT and PL-NIBUT values were 4.6 ± 2.3 s for the naked eye, 6.6 ± 6.6 s for narafilcon A, and 11.3 ± 3.5 s for verofilcon A. verofilcon A had significantly higher PL-NIBUT than the naked eye and narafilcon A (p < 0.05). SPK (0.16 ± 0.48 vs. 0.00 ± 0.00, p < 0.01) and conjunctival hyperemia (1.15 ± 0.82 vs. 0.49 ± 0.50, p < 0.01) scores were lower when wearing verofilcon A than narafilcon A. The ocular comfort score of wearing SCLs was higher with verofilcon A than with narafilcon A (8.7 ± 1.8 vs. 9.8 ± 0.5, p < 0.01). The ocular comfort score for wearing verofilcon A was higher, regardless of the baseline NIBUT. CONCLUSION: The results of this study showed a consistent surface-wetting advantage of verofilcon A in patients with ocular discomfort. verofilcon A was used comfortably in patients with low NIBUT scores at baseline. The findings suggest that verofilcon A is recommended for SCL wearers experiencing SCL-related dry eye symptoms and discomfort.


Subject(s)
Contact Lenses, Hydrophilic , Dry Eye Syndromes , Hyperemia , Humans , Dry Eye Syndromes/etiology , Hydrogels , Silicones , Tears
18.
Int J Mol Sci ; 25(5)2024 Feb 24.
Article in English | MEDLINE | ID: mdl-38473902

ABSTRACT

The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk to patients. Non-destructive and non-contact sensing techniques are essential in addressing this threat. Digital holographic tomography emerges as a promising solution. This allows for the 3D reconstruction of the refractive index distribution in biological samples, enabling label-free visualization and the quantitative analysis of biofilms. This tool provides insight into the dynamics of biofilm formation and maturation on the surface of transparent materials. Applying digital holographic tomography for biofilm examination has the potential to advance our ability to combat the antibiotic bacterial resistance crisis. A recent study focused on characterizing biofilm formation and maturation on six soft contact lens materials (three silicone hydrogels, three hydrogels), with a particular emphasis on Staphylococcus epidermis and Pseudomonas aeruginosa, both common culprits in ocular infections. The results revealed species- and time-dependent variations in the refractive indexes and volumes of biofilms, shedding light on cell dynamics, cell death, and contact lens material-related factors. The use of digital holographic tomography enables the quantitative analysis of biofilm dynamics, providing us with a better understanding and characterization of bacterial biofilms.


Subject(s)
Biofilms , Contact Lenses, Hydrophilic , Humans , Bacteria , Anti-Bacterial Agents , Hydrogels , Contact Lenses, Hydrophilic/microbiology , Pseudomonas aeruginosa/physiology
19.
Ophthalmic Physiol Opt ; 44(4): 727-736, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38525850

ABSTRACT

PURPOSE: This study addressed the utilisation of machine learning techniques to estimate tear osmolarity, a clinically significant yet challenging parameter to measure accurately. Elevated tear osmolarity has been observed in contact lens wearers and is associated with contact lens-induced dry eye, a common cause of discomfort leading to discontinuation of lens wear. METHODS: The study explored machine learning, regression and classification techniques to predict tear osmolarity using routine clinical parameters. The data set consisted of 175 participants, primarily healthy subjects eligible for soft contact lens wear. Various clinical assessments were performed, including symptom assessment with the Ocular Surface Disease Index and 5-Item Dry Eye Questionnaire (DEQ-5), tear meniscus height (TMH), tear osmolarity, non-invasive keratometric tear film break-up time (NIKBUT), ocular redness, corneal and conjunctival fluorescein staining and Meibomian glands loss. RESULTS: The results revealed that simple linear regression was insufficient for accurate osmolarity prediction. Instead, more advanced regression models achieved a moderate level of predictive power, explaining approximately 32% of the osmolarity variability. Notably, key predictors for osmolarity included NIKBUT, TMH, ocular redness, Meibomian gland coverage and the DEQ-5 questionnaire. In classification tasks, distinguishing between low (<299 mOsmol/L), medium (300-307 mOsmol/L) and high osmolarity (>308 mOsmol/L) levels yielded an accuracy of approximately 80%. Key parameters for classification were similar to those in regression models, emphasising the importance of NIKBUT, TMH, ocular redness, Meibomian glands coverage and the DEQ-5 questionnaire. CONCLUSIONS: This study highlights the potential benefits of integrating machine learning into contact lens research and practice. It suggests the clinical utility of assessing Meibomian glands and NIKBUT in contact lens fitting and follow-up visits. Machine learning models can optimise contact lens prescriptions and aid in early detection of conditions like dry eye, ultimately enhancing ocular health and the contact lens wearing experience.


Subject(s)
Dry Eye Syndromes , Machine Learning , Tears , Humans , Osmolar Concentration , Male , Female , Adult , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/metabolism , Middle Aged , Young Adult , Contact Lenses, Hydrophilic/adverse effects , Surveys and Questionnaires
20.
Eye Contact Lens ; 50(4): 177-182, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38305377

ABSTRACT

PURPOSE: To evaluate a new in vitro technique for measuring soft contact lens wettability using a nonmodified commercial videokeratoscope, the Medmont E300. To this end, the capability of different artificial tears containing hyaluronic acid (HA) to improve soft contact lens wettability in vitro was investigated. METHODS: An experimental in vitro study was conducted to assess the wetting properties of three artificial tears containing different concentrations of HA (0.1%, 0.2%, and 0.3%) on soft contact lenses. A saline solution was used as the control. For each solution, 15 hydrogel (Ocufilcon D) contact lenses and 15 silicone-hydrogel (Somofilcon A) contact lenses were evaluated. The in vitro wettability of the lenses was measured using the Medmont E300 with a self-developed technique, which involved measuring the tear film surface quality (TFSQ) mean, TFSQ area, TFSQ central, and TFSQ inferior. RESULTS: Compared with the saline solution, all the concentration of HA (0.1%, 0.2%, and 0.3%) improved the in vitro wettability of both soft contact lenses by decreasing their TFSQ mean and TFSQ area ( P <0.05). Regression models revealed an exponential relationship between contact lens wettability and the concentration of HA for both soft contact lenses ( R >0.5, P <0.05). Furthermore, the hydrogel contact lens presented a wetter surface than the silicone-hydrogel contact lens ( P <0.05). CONCLUSIONS: The measurement of in vitro wettability of soft contact lenses with a nonmodified Medmont E300 seems to be a useful technique to evaluate the wetting properties of contact lens products.


Subject(s)
Contact Lenses, Hydrophilic , Lubricant Eye Drops , Humans , Wettability , Saline Solution , Hydrogels , Silicones
SELECTION OF CITATIONS
SEARCH DETAIL
...