Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.957
Filter
1.
Anat Histol Embryol ; 53(4): e13068, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38837763

ABSTRACT

A comprehensive light and ultrastructural examination of the cornea in Domestic Pigs (Sus scrofa domesticus) revealed four distinct layers: the anterior epithelium, corneal stroma, Descemet's membrane and endothelium. Although Bowman's layer was not distinctly identified through histology, histochemical analysis indicated the presence of a rudimentary Bowman's layer, possibly vestigial from evolution. Scanning electron microscopy of the outer corneal surface unveiled two cell types, characterized by micro-projections, with light cells exhibiting shorter, thicker projections compared to dark cells. Examination of the inner surface via scanning electron microscopy demonstrated an endothelial layer devoid of cilia and microvilli, yet faint round to oval elevations were observed, potentially representing cell nuclei. Transmission electron microscopy unveiled that basal cells of the anterior epithelium closely adhered to the basement membrane, featuring half desmosomes along the basal surface. These basal cells extensively interconnected through interdigitations and a few desmosomes. The superficial cell layer consisted of a few rows of closely attached flat cells, forming a leak-proof layer with zona occludens. The outermost cells of this layer displayed fine projections to enhance the surface area, facilitating tear film distribution. At lower magnification, Transmission electron microscopy of the corneal stroma revealed alternating light and dark bands, with light bands representing transverse sections of collagen fibril lamellae and dark bands corresponding to longitudinal or oblique sections. Spindle-shaped keratocytes (fibroblasts) were identified as the primary stromal cells, intermingled between the lamellae, and featured long processes in close contact with neighbouring keratocytes. Overall, the histomorphology of the pig cornea resembles that of the human cornea except indistinct Bowman's membrane. This detailed understanding of the normal corneal structure in pigs hold great significance for biomedical research, providing a valuable reference for studies involving this animal model.


Subject(s)
Cornea , Microscopy, Electron, Scanning , Microscopy, Electron, Transmission , Sus scrofa , Animals , Cornea/ultrastructure , Cornea/anatomy & histology , Microscopy, Electron, Transmission/veterinary , Microscopy, Electron, Scanning/veterinary , Sus scrofa/anatomy & histology , Corneal Stroma/ultrastructure , Endothelium, Corneal/ultrastructure , Endothelium, Corneal/anatomy & histology , Epithelium, Corneal/ultrastructure , Descemet Membrane/ultrastructure , Descemet Membrane/anatomy & histology , Swine/anatomy & histology , Bowman Membrane/ultrastructure , Bowman Membrane/anatomy & histology
2.
Invest Ophthalmol Vis Sci ; 65(6): 23, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38874964

ABSTRACT

Purpose: To explore differences in the relationship between gestational age (GA) and birth weight (BW) percentile and ocular geometry between males and females. Methods: The Gutenberg Prematurity Eye Study involved a prospective ophthalmic examination of adults, aged 18 to 52 years, who were born preterm or at term, in Germany. The associations between GA and BW percentile on the main outcome measures were evaluated by uni- and multivariable linear regression analyses. The main outcome measures were central corneal thickness, corneal radius, anterior chamber depth, lens thickness, posterior segment length, and central foveal thickness. Potential sex-specific differences and an effect modification by sex were analyzed. Results: This study involved 438 participants (245 females, 193 males) with an average age of 28.6 ± 8.7 years. In female participants, central foveal thickness was negatively associated with a higher GA (B = -2.99; P < 0.001). Similarly, male participants also demonstrated a negative association between central foveal thickness and GA (B = -4.27; P < 0.001). The multivariable model with effect modification revealed that the central foveal thickness was thicker with lower GA. There was an association between the effect modification of GA with sex and central foveal thickness, demonstrating a more pronounced effect of GA on central foveal thickness in male participants (B = 1.29; P = 0.04). Conclusions: This study identified a sex-specific correlation between lower GA and thicker central foveal thickness, suggesting differences in the developmental trajectory of this biometric parameter concerning GA. A thicker central foveal thickness might affect the visual acuity of individuals born preterm in adulthood, with a more pronounced impact in males and a potential predisposition to age-related diseases later in life. Sex did not influence the association of GA or BW percentile to other ocular geometric parameters.


Subject(s)
Birth Weight , Gestational Age , Humans , Male , Female , Prospective Studies , Adult , Young Adult , Adolescent , Middle Aged , Birth Weight/physiology , Sex Factors , Infant, Newborn , Fovea Centralis/diagnostic imaging , Cornea/anatomy & histology , Cornea/diagnostic imaging , Tomography, Optical Coherence/methods , Anterior Chamber/diagnostic imaging , Anterior Chamber/anatomy & histology , Infant, Premature , Lens, Crystalline/diagnostic imaging , Lens, Crystalline/anatomy & histology , Germany , Visual Acuity/physiology , Posterior Eye Segment/diagnostic imaging , Posterior Eye Segment/anatomy & histology , Posterior Eye Segment/pathology
3.
BMC Ophthalmol ; 24(1): 230, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822272

ABSTRACT

BACKGROUND: Standardized corneal densitometry (CD) values in large samples of healthy Chinese individuals are scarce. Therefore, we aimed to determine the standard CD values using a Scheimpflug camera in healthy corneas, investigate the correlations of sex, age, and ocular parameters with corneal density, and explore the impact of corneal density on the forward scattering and optical quality of the eye. METHODS: This retrospective observational study involved 990 healthy Chinese individuals, including 494 males and 496 females (mean age: 23.88 ± 6.90 years). The CD values at various depths and radial areas of 0-12 mm were measured using a Scheimpflug camera. Densitometric measurements were expressed in standardized grayscale units (GSU). The optical scatter index (OSI), modulation transfer function cutoff values (MTFcutoff), and Strehl's ratio (SR) were also determined using an optical quality analysis system. RESULTS: The average CD within a 12 mm diameter area was 16.26 ± 1.35 GSU. The highest and lowest optical densities at different depths were observed in the anterior (21.41 ± 2.16 GSU) and posterior (12.00 ± 1.01 GSU) layers, respectively (P < 0.001). Similarly, the maximum and minimum optical densities at different radial areas were observed in the 10-12 mm (14.09 ± 0.93 GSU) and 2-6 mm (25.93 ± 4.77 GSU) circles, respectively (P < 0.001). There was no significant difference in the average CD within a 12 mm diameter area between males and females (P > 0.05). However, upon adjusting for age, central corneal thickness (CCT), corneal curvature, white-to-white (WTW) corneal diameter, and axial length, females exhibited a greater average CD within the 12 mm diameter and in the 6-10 mm and 10-12 mm circles than males. Age-related changes in CD were evident, except in the 2-6 mm circle. CCT, corneal curvature, WTW corneal diameter, and partial depth correlated with CD in the radial area, and CD in different areas correlated with the OSI, MTFcutoff, and SR (P < 0.05). CONCLUSIONS: This study provides the normative CD measurement data of Chinese adults with healthy corneas, emphasizing the significance of sex, age, CCT, corneal curvature, and WTW corneal diameter in CD evaluation. Notably, elevated CD can lead to increased forward scattering within the eye, thereby affecting the optical quality.


Subject(s)
Cornea , Densitometry , Humans , Female , Male , Cornea/anatomy & histology , Cornea/diagnostic imaging , Adult , Retrospective Studies , Young Adult , Middle Aged , China , Adolescent , Sex Factors , Reference Values , Age Factors , Healthy Volunteers , Aged , Asian People , East Asian People
4.
Strabismus ; 32(2): 85-90, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38708857

ABSTRACT

INTRODUCTION: The Spiral of Tillaux describes the historically accepted insertion distances of the medial rectus, inferior rectus, lateral rectus, and superior rectus from the limbus: 5.5 mm, 6.5 mm, 6.9 mm, and 7.7 mm, respectively. The corneal diameters are historically accepted to be 11.7 mm horizontally and 10.6 mm vertically in adults. We investigated the variability of the insertion distances of the extraocular rectus muscles from the limbus as well as the corneal diameters using eyes from human cadavers and compared our measurements to these historically accepted measurements. METHODS: A sample of 60 eyes were included. For each eye, a 360 peritomy was conducted and the conjunctiva bluntly dissected to view the sclera. Muscle hooks were utilized to isolate the extraocular rectus muscles. Calipers were used to measure the insertion distances of the rectus muscles as well as the corneal diameters. RESULTS: The mean rectus muscle insertions distances from the limbus were medial 5.28 mm, inferior 5.72 mm, lateral 6.40 mm, and superior 6.78 mm. These insertion distances were shorter than the historical benchmarks (p < .01). However, observed maximum distances of the rectus muscles were all greater than the historically accepted benchmarks, with the medial, inferior, lateral, and superior rectus muscles being 6.4 mm, 7.3 mm, 7.4 mm, and 7.8 m from the limbus, respectively. The mean width and height of the cornea were 11.7 mm and 10.7 mm, respectively, and similar to the expected ranges. CONCLUSION: This study concludes that variability does exist from the historically accepted Spiral of Tillaux measurements. In addition, significant variation exists between male and female rectus muscle insertions. However, we did confirm that the rectus muscles followed the same spiral pattern described by the Spiral of Tillaux and concluded that the corneal diameters are consistent with previously accepted values.


Subject(s)
Cadaver , Cornea , Oculomotor Muscles , Humans , Female , Male , Oculomotor Muscles/anatomy & histology , Aged , Cornea/anatomy & histology , Middle Aged , Aged, 80 and over , Adult
5.
BMC Ophthalmol ; 24(1): 207, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711043

ABSTRACT

PURPOSE: To understand the ocular biometric parameters characteristics and refractive errors in 3-to 6-year-old preschool children in Chengdu, China, and to investigate the prevalence of refractive errors. METHOD: A school-based cross-sectional study was conducted in Chengdu from 2020 to2022 with a total of 666 kindergartens. All children were measured by non-cycloplegic autorefraction and uncorrected visual acuity (UCVA) and ocular biometric parameters. Finally, univariate linear regression models were used to analyze the relationship between ocular biometric parameters and refraction. RESULTS: A total of 108,578 preschool children aged 3-6 underwent examinations, revealing a myopia prevalence of 6.1%. The mean axial length (AL), keratometry (K), corneal radius (CR), axial length/corneal radius (AL/CR) Ratio, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were 22.35 ± 0.69 mm, 43.35 ± 1.58 D, 7.80 ± 0.28 mm, 2.87 ± 0.08, 533.31 ± 32.51 µm, 2.70 ± 0.28 mm, 3.91 ± 0.27 mm, and 15.20 ± 0.68 mm, respectively. With increasing age, AL, CR, AL/CR ratio, CCT, ACD, LT, and VCD also increased. Regardless of age, males consistently exhibited longer AL, flatter corneal curvature, shallower ACD, thicker CCT, thinner LT, and longer VCD compared to females. AL, K, CR, LT, and VCD all showed significant linear relationships with SE (all P < 0.001) in univariate linear regression analysis after adjusting for gender and age. CONCLUSION: The prevalence of myopia among preschool children aged 3-6 in Chengdu is relatively low. Ocular biometric parameters affecting refractive errors include AL, K, CR, LT, and VCD. The preschool period serves as a critical phase for myopia prevention and control.


Subject(s)
Biometry , Refraction, Ocular , Visual Acuity , Humans , Female , Male , Cross-Sectional Studies , China/epidemiology , Refraction, Ocular/physiology , Child, Preschool , Child , Visual Acuity/physiology , Prevalence , Axial Length, Eye , Cornea/pathology , Cornea/anatomy & histology , Refractive Errors/epidemiology , Refractive Errors/physiopathology , Anterior Chamber/diagnostic imaging , Anterior Chamber/pathology , Myopia/epidemiology , Myopia/physiopathology
6.
BMJ Open ; 14(5): e078018, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38692719

ABSTRACT

OBJECTIVE: To investigate the differences in myopia prevalence and ocular biometry in children and adolescents in Chongqing and Tibet, China. DESIGN: Cross-sectional study. SETTING: The study included children and adolescents aged 6-18 years in Chongqing, a low-altitude region, and in Qamdo, a high-altitude region of Tibet. PARTICIPANTS: A total of 448 participants in Qamdo, Tibet, and 748 participants in Chongqing were enrolled in this study. METHODS: All participants underwent uncorrected visual acuity assessment, non-cycloplegic refraction, axial length (AL) measurement, intraocular pressure (IOP) measurement and corneal tomography. And the participants were grouped according to age (6-8, 9-11, 12-14 and 15-18 years group), and altitude of location (primary school students: group A (average altitude: 325 m), group B (average altitude: 2300 m), group C (average altitude: 3250 and 3170 m) and group D (average altitude: 3870 m)). RESULTS: There was no statistical difference in mean age (12.09±3.15 vs 12.2±3.10, p=0.549) and sex distribution (males, 50.4% vs 47.6%, p=0.339) between the two groups. The Tibet group presented greater spherical equivalent (SE, -0.63 (-2.00, 0.13) vs -0.88 (-2.88, -0.13), p<0.001), shorter AL (23.45±1.02 vs 23.92±1.19, p<0.001), lower prevalence of myopia (39.7% vs 47.6%, p=0.008) and flatter mean curvature power of the cornea (Km, 43.06±1.4 vs 43.26±1.36, p=0.014) than the Chongqing group. Further analysis based on age subgroups revealed that the Tibet group had a lower prevalence of myopia and higher SE in the 12-14, and 15-18 years old groups, shorter AL in the 9-11, 12-14 and 15-18 years old groups, and lower AL to corneal radius of curvature ratio (AL/CR) in all age subgroups compared with the Chongqing group, while Km was similar between the two groups in each age subgroup. Simple linear regression analysis showed that SE decreased with age in both the Tibet and Chongqing groups, with the Tibet group exhibiting a slower rate of decrease (p<0.001). AL and AL/CR increased with age in both the Tibet and Chongqing groups, but the rate of increase was slower in the Tibet group (p<0.001 of both). Multiple linear regression analysis revealed that AL had the greatest effect on SE in both groups, followed by Km. In addition, the children and adolescents in Tibet presented thinner corneal thickness (CCT, p<0.001), smaller white to white distance (WTW, p<0.001), lower IOP (p<0.001) and deeper anterior chamber depth (ACD, p=0.015) than in Chongqing. Comparison of altitude subgroups showed that the prevalence of myopia (p=0.002), SE (p=0.031), AL (p=0.001) and AL/CR (p<0.001) of children at different altitudes was statistically different but the Km (p=0.189) were similar. The highest altitude, Tengchen County, exhibited the lowest prevalence of myopia and greatest SE among children, and the mean AL also decreased with increasing altitude. CONCLUSIONS: Myopia prevalence in Tibet was comparable with that in Chongqing for students aged 6-8 and 9-11 years but was lower and myopia progressed more slowly for students aged 12-14 and 15-18 years than in Chongqing, and AL was the main contributor for this difference, which may be related to higher ultraviolet radiation exposure and lower IOP in children and adolescents at high altitude in Tibet. Differences in AL and AL/CR between Tibet and Chongqing children and adolescents manifested earlier than in SE, underscoring the importance of AL measurement in myopia screening.


Subject(s)
Altitude , Biometry , Myopia , Refraction, Ocular , Humans , Adolescent , Child , Cross-Sectional Studies , Male , Female , Tibet/epidemiology , Myopia/epidemiology , Prevalence , China/epidemiology , Refraction, Ocular/physiology , Visual Acuity , Axial Length, Eye/diagnostic imaging , Intraocular Pressure/physiology , Cornea/diagnostic imaging , Cornea/pathology , Cornea/anatomy & histology
7.
Cornea ; 43(6): 764-770, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38478761

ABSTRACT

PURPOSE: The purpose of this study was to investigate the associations between central corneal endothelial cell density (ECD), endothelial morphology, and corneal thickness (central corneal thickness) with the anterior chamber depth, corneal volume (CV), white-to-white (WTW) distance, mean anterior chamber angle (CAmean), and gender in healthy individuals. METHODS: This observational study included 136 healthy volunteers. The ECD, coefficient of variation of cell area, and hexagonal cell appearance ratio (%Hex) were measured by means of specular microscopy. The central corneal thickness, anterior chamber depth, CV, WTW distance, and the angle width of 12 points were taken by the Pentacam HR Scheimpflug anterior segment imaging. The arithmetical mean of the 12 points was considered as the CAmean. We used mixed effect linear regression model for the statistical analysis of the data. RESULTS: ECD was positively correlated with CV ( P = 0.028), while after adjusting for age, it was negatively correlated with age ( P < 0.001). Coefficient of variation of cell area was positively correlated with CAmean ( P = 0.036), while after adjusting for age, it was positively correlated with age ( P < 0.001) and CAmean ( P = 0.005). Hex was negatively correlated with WTW ( P = 0.023) and CAmean ( P = 0.025), and after adjusting for age, this correlation remained the same ( P = 0.029 when correlated with WTW and P = 0.035 with CAmean). CONCLUSIONS: There were significant changes in the morphology of the corneal endothelial cells in eyes with wider anterior chamber angle. Greater pleomorphism and polymegethism of the corneal endothelium was observed in healthy patients with wider CAmean. Deepening of the anterior chamber as myopia progresses could render the corneal endothelium more fragile and susceptible to mechanical stress, which is an area worthy of further study.


Subject(s)
Endothelium, Corneal , Healthy Volunteers , Humans , Endothelium, Corneal/cytology , Endothelium, Corneal/diagnostic imaging , Male , Female , Adult , Cell Count , Middle Aged , Young Adult , Cornea/diagnostic imaging , Cornea/anatomy & histology , Anterior Eye Segment/diagnostic imaging , Anterior Eye Segment/anatomy & histology , Aged , Anterior Chamber/diagnostic imaging , Anterior Chamber/anatomy & histology , Corneal Pachymetry
8.
Ophthalmic Physiol Opt ; 44(4): 737-745, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38217323

ABSTRACT

PURPOSE: To evaluate the relative positions of modern soft contact lenses (SCLs) relative to the limbus/cornea and the pupil. METHODS: Sixty images of the anterior eyes of 101 subjects were acquired over 10 s while participants fixated the centre of the camera lens located 33 cm in front of the eye in a well-lit (300 lux) clinic. Custom validated image analysis software was used to locate the boundaries of the contact lenses, pupils and corneas (limbus). Horizontal and vertical relative positions of the contact lens, pupil and limbus were calculated from the fitted boundaries. RESULTS: The mean (standard deviation) pupil and corneal diameters for all subjects were 3.84 mm, (0.83) and 11.97 mm (0.48), respectively. The mean [95% confidence interval] pupil centre was located 0.28 mm [0.26, 0.30] nasally and 0.07 mm [0.05, 0.10] superiorly to the corneal centre. Consistent with clinical observations, the contact lenses centred accurately relative to the corneal centre both nasally 0.04 mm [0.01, 0.07] and inferiorly -0.01 mm [-0.06, 0.03]. However, regardless of the eye, the contact lens was significantly (p < 0.001) decentred relative to the pupil centre both temporally -0.23 mm [-0.26, -0.20] and inferiorly -0.08 mm [-0.12, -0.04]. Decentration magnitudes were significantly correlated between the right and left eyes. CONCLUSIONS: Spherical SCLs centred well on the cornea but temporally and inferiorly from the primary line of sight (pupil centre), due to the differences in the location of the pupil and corneal centres. Contrary to some previous reports, there was no evidence that lens optics or material affected lens centration significantly.


Subject(s)
Contact Lenses, Hydrophilic , Pupil , Humans , Male , Adult , Female , Pupil/physiology , Young Adult , Cornea/diagnostic imaging , Cornea/anatomy & histology , Middle Aged , Adolescent
9.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1857-1863, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38206413

ABSTRACT

PURPOSE: To compare central corneal thickness (CCT) measured with optical coherence tomography (OCT) using an automatic algorithm (A-OCT) vs. manual measurements (M-OCT) with respect to the gold standard ultrasound pachymetry (USP). METHODS: CCT measurements were performed on both eyes of 28 healthy subjects at four times of the day. A-OCT used an automatic software analysis of the corneal image, M-OCT was performed by two operators by setting a digital calliper on the corneal borders, and USP was performed after corneal anesthesia. Measurements were compared using a three-way repeated measures ANOVA. Bland-Altman plots were used to evaluate the agreement between OCT measurements and USP. RESULTS: Both A-OCT and M-OCT significantly underestimated the USP measures, with the mean difference, i.e., the systematic error, being larger for A-OCT (- 19.0 µm) than for M-OCT (- 6.5 µm). Good reproducibility between the two operators was observed. Bland-Altman plots showed that both OCT methods suffered from proportional errors, which were not affected by time and eye. CONCLUSIONS: Measuring CCT with OCT yielded lower values than USP. Therefore, clinicians should be aware that corneal thickness values may be influenced by the measurement method and that the various devices should not be used interchangeably in following up a given patient. Intriguingly, M-OCT had less systematic error than A-OCT, an important outcome that clinicians should consider when deciding to use an OCT device.


Subject(s)
Algorithms , Cornea , Corneal Pachymetry , Healthy Volunteers , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Cornea/diagnostic imaging , Cornea/anatomy & histology , Male , Female , Corneal Pachymetry/methods , Adult , Reproducibility of Results , Young Adult , Middle Aged , Organ Size
10.
Eye Contact Lens ; 50(1): 23-28, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37713630

ABSTRACT

PURPOSE: To measure the corneoscleral limbus and anterior sclera parameters of normal Chinese adults by swept-source optical coherence tomography (OCT). MATERIALS AND METHODS: In this cross-sectional study, a total of 56 Chinese subjects with ametropia were evaluated in the Eye Hospital of Wenzhou Medical University from September 2020 to December 2020, including 26 (46.4%) men, with an average age of 24.7±1.8 years old. The OCT SS-1000 (CASIA, Tomey, Tokyo, Japan) was used to measure the sagittal height, corneoscleral junction (CSJ) angle, and scleral angle. RESULTS: The chord was across the corneal center and the line connecting the center of the cornea and the center of the chord was perpendicular to the chord. The mean sagittal height at chord lengths of 10.0, 12.3, and 15.0 mm were 1,756±72, 2,658±110, and 3,676±155 µm, respectively. The absolute values of the differences between horizontal and vertical meridians at three chord lengths were 54±40, 70±67, and 117±95 µm, respectively. One-way analysis of variance showed that the differences of CSJ angles at 12.3-mm chord and scleral angles at 15.0-mm chord in the four segments were statistically significant ( F values were 32.01 and 13.37, respectively, both P <0.001). The CSJ angles from low to high were 176.53±2.14° (nasal), 178.66±1.84° (inferior), 179.13±1.20° (temporal), and 179.31±1.68° (superior), and 87.5% of the nasal angles were less than 179°. The scleral angles from high to low were 38.35±2.47° (temporal), 38.26±3.37° (superior), 35.37±3.10° (nasal), and 35.30±4.71° (inferior). CONCLUSIONS: The morphology of corneoscleral limbus and anterior sclera is asymmetrical in normal Chinese adults. The nasal side of the corneoscleral limbus has the largest angle, and the superior and temporal sides of the scleral angle are larger.


Subject(s)
Sclera , Tomography, Optical Coherence , Adult , Male , Humans , Young Adult , Female , Sclera/diagnostic imaging , Sclera/anatomy & histology , Tomography, Optical Coherence/methods , Cross-Sectional Studies , Cornea/anatomy & histology , China
11.
J Morphol ; 285(1): e21662, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38100743

ABSTRACT

The Australian lungfish, Neoceratodus forsteri (Krefft 1870), is the sole extant member of the Ceratodontidae within the Dipnoi, a small order of sarcopterygian (lobe-finned) fishes, that is thought to be the earliest branching species of extant lungfishes, having changed little over the last 100 million years. To extend studies on anatomical adaptations associated with the fish-tetrapod transition, the ultrastructure of the cornea and iris is investigated using light and electron (transmission and scanning) microscopy to investigate structure-function relationships and compare these to other vertebrate corneas (other fishes and tetrapods). In contrast to previous studies, the cornea is found to have only three main components, comprising an epithelium with its basement membrane, a stroma with a Bowman's layer and an endothelium, and is not split into a dermal (secondary) spectacle and a scleral cornea. The epithelial cells are large, relatively low in density and similar to many species of non-aquatic tetrapods and uniquely possess numerous surface canals that contain and release mucous granules onto the corneal surface to avoid desiccation. A Bowman's layer is present and, in association with extensive branching and anastomosing of the collagen fibrils, may be an adaptation for the inhibition of swelling and/or splitting of the stroma during its amphibious lifestyle. The dorsal region of the stroma possesses aggregations of pigment granules that act as a yellow, short wavelength-absorbing filter during bright light conditions. Desçemet's membrane is absent and replaced by an incomplete basement membrane overlying a monocellular endothelium. The iris is pigmented, well-developed, vascularised and contractile containing reflective crystals anteriorly. Based upon its ultrastructure and functional adaptations, the cornea of N. forsteri is more similar to amphibians than to other bony fishes and is well-adapted for an amphibious lifestyle.


Subject(s)
Biological Evolution , Cornea , Fishes , Iris , Animals , Australia , Cornea/anatomy & histology , Fishes/anatomy & histology , Iris/anatomy & histology
12.
Comp Med ; 73(5): 373-377, 2023 Oct 29.
Article in English | MEDLINE | ID: mdl-38087405

ABSTRACT

Large animal models are essential to research in facial paralysis, face transplant, craniofacial surgery, and ophthalmology. Pigs are a well-studied species with high similarity to human anatomy and physiology for these research areas. However, in contrast to cats and dogs protecting the cornea and eye is difficult in swine due to the inability to use an Elizabethan collar (E-collar) and the complexity of placing and maintaining a temporary tarsorrhaphy for corneal protection due to the strength of the pig levator muscle. This study presents an effective method to provide corneal and eye protection in the domestic swine for at least 50 d. Furthermore, protection of the eye and face is achieved through the innovative use of a modified ophthalmologic face shield. The findings from this study will advance large animal research in these fields, enabling innovation in surgery and tissue engineering in areas of both craniofacial and ophthalmologic research.


Subject(s)
Cornea , Muscles , Humans , Swine , Cats , Animals , Dogs , Cornea/surgery , Cornea/anatomy & histology , Cornea/physiology , Models, Animal
14.
BMC Ophthalmol ; 23(1): 218, 2023 May 16.
Article in English | MEDLINE | ID: mdl-37194016

ABSTRACT

PURPOSE: To evaluate a new non-contact instrument (OA-2000) measuring the ocular biometry parameters of silicone oil (SO)-filled aphakic eyes, as compared with IOLMaster 700. METHODS: Forty SO-filled aphakic eyes of 40 patients were enrolled in this cross-sectional clinical trial. The axial length (AL), central corneal thickness (CCT), keratometry ((flattest keratometry) Kf and (steep keratometry, 90° apart from Kf) Ks), and axis of the Kf (Ax1) were measured with OA-2000 and IOLMaster 700. The coefficient of variation (CoV) was calculated to assess the repeatability. The correlation was evaluated by the Pearson coefficient. Bland-Altman analysis and paired t test were used to analyze the agreements and differences of parameters measured by the two devices, respectively. RESULTS: The mean AL obtained with the OA-2000 was 23.57 ± 0.93 mm (range: 21.50 to 25.68 mm), and that obtained with the IOLMaster 700 was 23.69 ± 0.94 mm (range: 21.85 to 25.86 mm), resulting in a mean offset of 0.124 ± 0.125 mm (p < 0.001). The mean offset of CCT measured by OA-2000 and IOLMaster 700 was 14.6 ± 7.5 µm (p < 0.001). However, the Kf, Ks and Ax1 values from the two devices were comparable (p > 0.05). All the measured parameters of the two devices showed strong linear correlations (all r ≥ 0.966). The Bland-Altman analysis showed a narrow 95% limits of agreement (LoA) of Kf, Ks and AL, but 95%LoA of CCT and Ax1 was wide, which were - 29.3 ~ 0.1 µm and-25.9 ~ 30.7°respectively. The CoVs of the biometric parameters obtained with OA-2000 were lower than 1%. CONCLUSION: In SO-filled aphakic eyes, the ocular parameters (including AL, Kf, Ks, Ax1, and CCT) measured by the OA-2000 and IOLMaster 700 had a good correlation. Two devices had an excellent agreement on ocular biometric measurements of Kf, Ks and AL. The OA-2000 provided excellent repeatability of ocular parameters in SO-filled aphakic eyes.


Subject(s)
Aphakia , Axial Length, Eye , Silicone Oils , Humans , Anterior Chamber/anatomy & histology , Biometry , Cornea/anatomy & histology , Cross-Sectional Studies , Reproducibility of Results , Retinal Diseases , Tomography, Optical Coherence
15.
BMC Ophthalmol ; 23(1): 225, 2023 May 19.
Article in English | MEDLINE | ID: mdl-37208745

ABSTRACT

PURPOSE: To investigate the distribution and changes in ocular biometry in 4-to to 9-year-old Chinese children and to compare the differences between age and genders in these parameters. METHODS: This was a school-based cross-sectional study. A total of 1,528 Chinese children, aged 4-9 years, from one primary school and 12 kindergartens, were included in the study. Axial length, corneal curvature, anterior chamber depth, and corneal diameter were measured for each child. RESULTS: AL and anterior chamber depth gradually increased with age in both genders. No significant changes in corneal curvature or corneal diameter were detected at different ages in either genders group. The mean ALs of males and females were 22.94 ± 0.80 mm and 22.38 ± 0.79 mm, respectively. The mean corneal curvatures of males and females were 43.05 ± 1.37 D and 43.75 ± 1.48 D, respectively. The mean anterior chamber depth of males and females were 3.47 ± 0.24 mm and 3.38 ± 0.25 mm, respectively. The mean corneal diameter of males and females were 12.08 ± 0.43 mm and 11.94 ± 0.44 mm, respectively. Females had consistently shorter ALs, shorter anterior chamber depth, smaller corneal diameter, and steeper corneal curvatures than males at any age. CONCLUSIONS: Boys had larger dimensions than girls for all ocular parameters except corneal curvature (flatter). Boys and girls showed similar trends for all parameters. Axial length and anterior chamber depth increased from 4 to 9 years of age, whereas corneal diameter and curvature did not change with age in either genders.


Subject(s)
Cornea , East Asian People , Child , Humans , Female , Male , Child, Preschool , Cross-Sectional Studies , Cornea/anatomy & histology , Asian People , Biometry/methods , Refraction, Ocular , Anterior Chamber/anatomy & histology , Axial Length, Eye
16.
Ophthalmic Physiol Opt ; 43(4): 860-873, 2023 07.
Article in English | MEDLINE | ID: mdl-37083081

ABSTRACT

PURPOSE: To evaluate the feasibility and repeatability of IOLMaster 700 biometry measurements in an adult population. Furthermore, to assess the value of the Quality Indicators (QIs) provided by the device. METHOD: As part of the large population-based Leipzig Research Centre for Civilization Diseases (LIFE) Adult-Study, randomly selected participants from Leipzig, Germany were evaluated with the ZEISS IOLMaster 700. Age range was 26-85 years, with 53% of participants above 70 years of age. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT) and keratometry (K) were assessed in 1767 right eyes. Measurements were repeated twice and in a subset of 1331 eyes, three times. Measurement feasibility was evaluated for three levels; successful, with warnings and failed, using the inbuilt QIs. Repeatability was assessed as within-subject standard deviation (SD) and repeatability limits were calculated. RESULTS: First measurement success rate for phakic eyes was over 99% for AL, CCT, ACD, over 98% for LT and over 97% for K. K had 16% eyes with warnings and the recommendation to repeat the measurement. Excluding the measurements with warnings resulted in a reduction of mean SD for AL from 48 to 4 µm and for mean K from 0.08 to 0.04 D. Repeatability for phakic eyes was 8 µm for AL, CCT, ACD and LT and 2.3 µm for CCT; 0.07 D and 0.12 D for mean K and delta K, respectively, for phakic cases without warnings (two measurements). CONCLUSIONS: In our population-based sample, the IOLMaster 700 collected data for AL, CCT, ACD, LT and K from the vast majority of eyes. Considering the built-in QIs improved the measurement variability substantially. Repeatability measurements indicate that clinically meaningful changes can be detected reliably with this instrument.


Subject(s)
Axial Length, Eye , Tomography, Optical Coherence , Adult , Humans , Middle Aged , Aged , Aged, 80 and over , Feasibility Studies , Axial Length, Eye/anatomy & histology , Tomography, Optical Coherence/methods , Reproducibility of Results , Prospective Studies , Cornea/diagnostic imaging , Cornea/anatomy & histology , Biometry/methods , Anterior Chamber/diagnostic imaging
17.
J Cataract Refract Surg ; 49(5): 474-478, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36700942

ABSTRACT

PURPOSE: To determine how much axial length (AL) and average keratometry (K) change over time in elderly patients and to assess clinical necessity of repeating biometry in instances where the second eye is operated on 6 months or more after the first. SETTING: Northwestern Memorial Hospital, Chicago, Illinois. DESIGN: Retrospective study. METHODS: Inclusion criteria were patients older than 35 years, with 2 biometry measurements over 6 months apart, measured with the IOL Master 700 from January 1, 2016, to September 15, 2020. Patients were excluded if they had any other intraocular surgery besides cataract. A linear mixed model and SPSS software was used to compare measurements among timepoints. RESULTS: 201 patients (402 eyes) were included (average age 73.3, 59.3% female). Average time between biometry measurements was 21.5 months (range 6 to 48 months). The mean change in AL was 0.04 mm (95% CI, 0.03 to 0.05, P = .10). The mean change in K was 0.01 diopters (95% CI, -0.10 to 0.30, P = .33). At the 6-month to 1-year interval (n = 73), mean change in AL was 0.04 mm. Mean change in AL did not significantly increase with greater time intervals. There was no correlation between time and ΔAL ( P = .70), nor between time and ΔK ( P = .98). CONCLUSIONS: In this cohort, biometric parameters did not change significantly over time. Repeating biometry at a 1- to 2-year interval for elderly patients receiving monofocal implants may offer limited benefit.


Subject(s)
Cornea , Lenses, Intraocular , Refraction, Ocular , Adult , Aged , Female , Humans , Male , Axial Length, Eye , Biometry , Cornea/anatomy & histology , Retrospective Studies
18.
Br J Ophthalmol ; 107(8): 1125-1131, 2023 08.
Article in English | MEDLINE | ID: mdl-35273019

ABSTRACT

BACKGROUND/AIMS: To evaluate whether anterior segment anatomy and axial length are associated with prematurity and perinatal factors in adults. METHODS: The Gutenberg Prematurity Eye Study examined adults born preterm and term aged 18-52 years. All participants underwent a prospective ophthalmic examination (optical biometry via a LenStar 900, Haag-Streit) in Germany. The associations between gestational age (GA), birth weight (BW) and BW percentile, retinopathy of prematurity (ROP) occurrence, ROP treatment and other perinatal factors with the main outcome measures were evaluated by univariate and multivariable linear regression analyses. Main outcome measures were corneal radius, white-to-white distance, anterior chamber depth, lens thickness and axial length. RESULTS: The study involved 861 eyes of 438 preterm and full-term individuals (aged 28.6±8.7 years, 245 females,). After adjustment for age and gender, a steeper corneal radius was associated with lower GA (B=0.02; p<0.001) and a lower BW percentile (B=0.003; p<0.001). A smaller white-to-white distance was linked to lower GA (B=0.02; p<0.001), a lower BW percentile (B=0.004; p<0.001) and postnatal ROP occurrence (B=-0.26; p<0.001). Decreased axial length was associated with lower GA at birth (B=0.05; p=0.002) and pre-eclampsia (B=-0.34; p=0.015). ROP-treated eyes had a shallower anterior chamber depth (B=-0.63; p=0.001) and increased lens thickness (B=0.64, p<0.001). CONCLUSION: Our analyses in adults demonstrate that the corneal morphology is influenced by GA and BW percentile, while the anterior chamber depth and lens thickness are affected by ROP treatment, namely laser therapy and cryotherapy. The present study highlights that perinatal factors lead to lifelong sequelae of ocular shape.


Subject(s)
Lens, Crystalline , Retinopathy of Prematurity , Infant, Newborn , Female , Adult , Humans , Retinopathy of Prematurity/diagnosis , Prospective Studies , Infant, Premature , Cornea/anatomy & histology , Gestational Age
19.
Eye (Lond) ; 37(3): 511-515, 2023 02.
Article in English | MEDLINE | ID: mdl-35190667

ABSTRACT

BACKGROUND/OBJECTIVES: We provide global averages and standard deviations for ocular biometry-axial length (AL), corneal radius of curvature (CR), anterior chamber depth (ACD), lens thickness (LT), white to white (WTW), and central corneal thickness (CT). We hope a better understanding of normal and abnormal values will help clinicians gain further insight into their surgical outcomes, especially for off-target eyes. SUBJECTS/METHODS: We searched the MEDLINE database using keywords "axial length, corneal power, anterior chamber depth, lens thickness, white to white, and corneal thickness." We included studies that reported averages and standard deviations on eye biometry for at least 1300 eyes. Global weighted averages and standard deviations were calculated using the Cochrane method. RESULTS: Fourteen studies were included, originating from Asia (Japan, Singapore, Myanmar, Iran, South Korea, China), Europe (Germany, United Kingdom, Portugal), Australia, and North America (United States). Global ocular biometry metrics were: AL-23.49 mm ± 1.35 mm, CR-7.69 mm ± 0.28 mm, ACD-3.10 mm ± 0.47 mm, WTW-11.80 mm ± 0.42 mm, LT-4.37 mm ± 0.43 mm, and CT-544 µm ± 38 µm. Total eyes per value ranged from 19,538 to 90,814. CONCLUSIONS: We report global ocular biometry averages and standard deviations. No eyes were from studies in Africa or South America, highlighting the need to publish eye biometry data from these continents. We hope that promoting a deeper understanding of biometry values will help clinicians gain insight into surgical outcomes and drive innovations in lens calculations.


Subject(s)
Axial Length, Eye , Lens, Crystalline , Humans , Axial Length, Eye/anatomy & histology , Cornea/anatomy & histology , Data Collection , Biometry/methods , Anterior Chamber/anatomy & histology , Refraction, Ocular
20.
J Cataract Refract Surg ; 49(1): 5-10, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36026703

ABSTRACT

PURPOSE: To evaluate the repeatability of the measurements provided by a new optical biometer (EyeStar 900) based on swept-source optical coherence tomography (SS-OCT) and their agreement with the measurements given by 2 validated biometers based on the same technology, the IOLMaster 700 and Argos. SETTING: IRCCS G.B. Bietti Foundation, Rome, Italy. DESIGN: Prospective evaluation of diagnostic test. METHODS: In a series of unoperated eyes, 3 consecutive scans were acquired with the EyeStar 900, and 1 with the IOLMaster 700 and the Argos. The following biometry parameters were analyzed: axial length (AL), keratometry (K), corneal astigmatism, central corneal thickness, corneal diameter (CD), anterior chamber depth (ACD), lens thickness (LT), and lens tilting. Repeatability was assessed using test-retest variability, the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC); agreement was based on the 95% limits of agreement. RESULTS: 56 eyes of 56 patients were analyzed. High repeatability was achieved for all measured parameters, as the CoV was <1% in most cases and ICC was >0.95 for all parameters. Good to high agreement was found among the measurements of the 3 optical biometers, although some statistically significant differences were detected between the EyeStar 900 and Argos (mean K, ACD, LT, and CD were higher with the Argos). The Argos measured a shorter AL in eyes >25 mm. CONCLUSIONS: The new generation SS-OCT EyeStar 900 optical biometer produces highly repeatable measurements that are in good agreement with those provided by 2 previously validated instruments.


Subject(s)
Axial Length, Eye , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Axial Length, Eye/anatomy & histology , Reproducibility of Results , Interferometry , Prospective Studies , Cornea/anatomy & histology , Biometry/methods , Anterior Chamber/diagnostic imaging , Anterior Chamber/anatomy & histology
SELECTION OF CITATIONS
SEARCH DETAIL
...