Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.165
Filter
2.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Article in English | MEDLINE | ID: mdl-38848055

ABSTRACT

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Subject(s)
Corneal Wavefront Aberration , Lens Implantation, Intraocular , Refraction, Ocular , Visual Acuity , Humans , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/etiology , Risk Factors , Visual Acuity/physiology , Refraction, Ocular/physiology , Multifocal Intraocular Lenses , Depth Perception/physiology , Corneal Topography , Cornea/physiopathology
4.
J Refract Surg ; 40(6): e392-e397, 2024 May.
Article in English | MEDLINE | ID: mdl-38848056

ABSTRACT

PURPOSE: To compare the effects of corneal allogenic intrastromal ring segment (CAIRS) implantation on topographical measurements and visual outcomes of patients with keratoconus with and without corneal cross-linking (CXL) prior to the time of implantation. METHODS: Sixty-seven eyes with corneal allograft intrastromal ring segment implantation (KeraNatural; Lions VisionGift) due to advanced keratoconus were included in the study. Thirty-seven eyes had no CXL and 30 eyes had had CXL before being referred to the authors. The changes in spherical equivalent (SE), uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), steep keratometry (K1), flat keratometry (K2), mean keratometry (Kmean), maximum keratometry (Kmax), and thinnest pachymetry were retrospectively analyzed 6 months after the implantation. RESULTS: The median age was 29 years in the CXL group and 24.0 years in the non-CXL group (P > .05), respectively. All topographical and visual parameters before implantation were similar in both groups (P > .05 for all parameters). At 6 months, CDVA, K1, and Kmean showed higher improvement in the non-CXL group than the CXL group (P = .030, .018, and .039, respectively). CONCLUSIONS: CAIRS surgery has a flattening effect on both the corneas with and without CXL. The cornea with prior CXL treatment had less flattening effect due to the stiffening effect of prior CXL. [J Refract Surg. 2024;40(6):e392-e397.].


Subject(s)
Collagen , Corneal Stroma , Corneal Topography , Cross-Linking Reagents , Keratoconus , Photosensitizing Agents , Prostheses and Implants , Prosthesis Implantation , Refraction, Ocular , Visual Acuity , Humans , Keratoconus/physiopathology , Keratoconus/metabolism , Keratoconus/drug therapy , Keratoconus/surgery , Corneal Stroma/metabolism , Corneal Stroma/surgery , Cross-Linking Reagents/therapeutic use , Visual Acuity/physiology , Adult , Male , Female , Photosensitizing Agents/therapeutic use , Retrospective Studies , Young Adult , Refraction, Ocular/physiology , Collagen/metabolism , Corneal Pachymetry , Riboflavin/therapeutic use , Photochemotherapy/methods , Adolescent , Ultraviolet Rays , Corneal Transplantation/methods , Middle Aged , Corneal Cross-Linking
5.
J Refract Surg ; 40(6): e362-e370, 2024 May.
Article in English | MEDLINE | ID: mdl-38848058

ABSTRACT

PURPOSE: To identify potential risk factors that increase the likelihood of re-treatment following keratorefractive lenticule extraction (KLEx) for myopia and myopic astigmatism. METHODS: This was a retrospective study of patients with myopia and myopic astigmatism who underwent KLEx using the VisuMax 500 laser (Carl Zeiss Meditec) between April 2015 and December 2020. Patients were assigned to one of two groups: the control group and the re-treatment group (if they had additional refractive surgery within 2 years of the primary treatment). The effect of different preoperative, intraoperative, and postoperative parameters on the re-treatment rate was analyzed. RESULTS: Overall 1,822 eyes of 938 patients were analyzed. In total, 2.96% of eyes (n = 54) underwent re-treatment. The re-treated patients were more likely to be women and have high myopia, high astigmatism, steep corneas, higher ocular residual astigmatism, and residual myopic and/or astigmatic refractive error. In contrast, no significant correlation was found between re-treatment rate and age, chord µ, type of astigmatism, and corneal thickness. CONCLUSIONS: Factors associated with higher rates of retreatment after KLEx included female gender, manifest refractive high myopia (> -5.00 diopters [D]), astigmatism (> 2.00 D), spherical equivalent (> 6.00 D), ocular residual astigmatism, steeper corneas, and postoperative residual myopic and astigmatic refractive errors. This study may help to preoperatively detect patients at risk for re-treatment, improve preoperative patient counseling, and optimize patient selection to reduce future re-treatment rates. [J Refract Surg. 2024;40(6):e362-e370.].


Subject(s)
Astigmatism , Lasers, Excimer , Myopia , Refraction, Ocular , Reoperation , Visual Acuity , Humans , Retrospective Studies , Male , Astigmatism/surgery , Astigmatism/physiopathology , Female , Adult , Risk Factors , Myopia/surgery , Myopia/physiopathology , Visual Acuity/physiology , Refraction, Ocular/physiology , Lasers, Excimer/therapeutic use , Young Adult , Corneal Stroma/surgery , Corneal Topography , Middle Aged , Adolescent , Corneal Surgery, Laser/methods
6.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Article in English | MEDLINE | ID: mdl-38717080

ABSTRACT

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Subject(s)
Astigmatism , Corneal Stroma , Lasers, Excimer , Myopia , Refraction, Ocular , Visual Acuity , Humans , Astigmatism/physiopathology , Astigmatism/surgery , Visual Acuity/physiology , Retrospective Studies , Adult , Refraction, Ocular/physiology , Male , Female , Myopia/surgery , Myopia/physiopathology , Young Adult , Corneal Stroma/surgery , Lasers, Excimer/therapeutic use , Corneal Topography , Follow-Up Studies , Treatment Outcome , Corneal Surgery, Laser/methods
7.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Article in English | MEDLINE | ID: mdl-38717081

ABSTRACT

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Subject(s)
Corneal Topography , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Surgery, Computer-Assisted , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Visual Acuity/physiology , Prospective Studies , Refraction, Ocular/physiology , Adult , Male , Female , Lasers, Excimer/therapeutic use , Double-Blind Method , Myopia/surgery , Myopia/physiopathology , Young Adult , Surgery, Computer-Assisted/methods , Middle Aged , Cornea/surgery , Cornea/physiopathology , Follow-Up Studies
8.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Article in English | MEDLINE | ID: mdl-38717083

ABSTRACT

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Subject(s)
Aberrometry , Astigmatism , Cornea , Corneal Stroma , Corneal Wavefront Aberration , Densitometry , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Corneal Wavefront Aberration/physiopathology , Prospective Studies , Myopia/surgery , Myopia/physiopathology , Adult , Female , Male , Lasers, Excimer/therapeutic use , Visual Acuity/physiology , Corneal Stroma/surgery , Cornea/surgery , Cornea/physiopathology , Young Adult , Refraction, Ocular/physiology , Astigmatism/surgery , Astigmatism/physiopathology , Corneal Surgery, Laser/methods , Corneal Topography
9.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Article in English | MEDLINE | ID: mdl-38717082

ABSTRACT

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Subject(s)
Corneal Stroma , Corneal Topography , Epithelium, Corneal , Hyperopia , Refraction, Ocular , Tomography, Optical Coherence , Visual Acuity , Humans , Hyperopia/surgery , Hyperopia/physiopathology , Prospective Studies , Corneal Stroma/surgery , Corneal Stroma/pathology , Male , Female , Adult , Visual Acuity/physiology , Epithelium, Corneal/surgery , Epithelium, Corneal/pathology , Refraction, Ocular/physiology , Middle Aged , Lasers, Excimer/therapeutic use , Young Adult , Corneal Wavefront Aberration/physiopathology , Corneal Surgery, Laser/methods , Eye Diseases, Hereditary
10.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Article in English | MEDLINE | ID: mdl-38717086

ABSTRACT

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Subject(s)
Cornea , Elasticity , Intraocular Pressure , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Humans , Cornea/physiopathology , Cornea/surgery , Adult , Female , Male , Biomechanical Phenomena , Lasers, Excimer/therapeutic use , Keratomileusis, Laser In Situ/methods , Young Adult , Elasticity/physiology , Myopia/surgery , Myopia/physiopathology , Intraocular Pressure/physiology , Photorefractive Keratectomy/methods , Visual Acuity/physiology , Refraction, Ocular/physiology , Middle Aged , Prospective Studies , Corneal Surgery, Laser/methods , Corneal Topography
11.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Article in Russian | MEDLINE | ID: mdl-38742501

ABSTRACT

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Subject(s)
Contact Lenses , Keratoconus , Sclera , Visual Acuity , Humans , Keratoconus/surgery , Keratoconus/diagnosis , Keratoconus/physiopathology , Keratoconus/therapy , Female , Male , Adult , Sclera/surgery , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Treatment Outcome , Corneal Topography , Prostheses and Implants , Young Adult , Prosthesis Fitting/methods , Adolescent , Corneal Stroma/surgery
12.
Invest Ophthalmol Vis Sci ; 65(5): 29, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38767907

ABSTRACT

Purpose: Keratoconus (KC) is a progressive corneal disease that can lead to corneal blindness if not properly managed. The purpose of this study was to identify genetic associations with KC in China and to investigate whether these genetic variants are associated with corneal thickness and corneal curvature in KC cases. Methods: A genome-wide association study was conducted on 853 patients with KC and 6248 controls. The KC cases were genotyped with the Illumina Infinium Human Asian Screening Array BeadChip, and the controls were genotyped with the Illumina Infinium Human Global Screening Array BeadChip. Genetic associations with KC, as well as correlations between the positive variants and corneal parameters including central corneal thickness (CCT) and mean keratometry (Km), were compared using PLINK version 1.90. Results: Our present study identified four single-nucleotide polymorphisms (SNPs) within four risk loci (PTGER3: rs2300163, EYA1: rs1077435, ASS1: rs141365191, and CHTF8: rs3743680) associated with KC in Chinese patients that reached genome-wide significance. Among the identified SNPs with P < 1.00 × 10-4, seven SNPs (FOSL2-PLB1: rs12622211, RXRA-COL5A1: rs3118515, rs3132306, rs1536482, rs3118520, KAT6B: rs192187772, RAP2A-IPO5: rs41361245) were observed to be associated with CCT, and one SNP (USP13: rs6767552) was found to be associated with Km. Conclusions: In the first genome-wide association study of KC with a relatively large study population in China, we identified four SNPs in four risk loci associated with the disease. The findings enriched the understanding of genetic susceptibility to KC and provided new insights into the genetic etiology of the disease.


Subject(s)
Asian People , Genetic Predisposition to Disease , Genome-Wide Association Study , Genotype , Keratoconus , Polymorphism, Single Nucleotide , Humans , Keratoconus/genetics , Female , Male , China/epidemiology , Adult , Asian People/genetics , Young Adult , Middle Aged , Cornea/pathology , Adolescent , Genetic Loci , Corneal Topography , East Asian People
13.
Curr Opin Ophthalmol ; 35(4): 315-321, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38700950

ABSTRACT

PURPOSE OF REVIEW: This manuscript summarizes contemporary research from 2018 to 2023 evaluating long-term (≥2 years) outcomes of corneal crosslinking (CXL) for progressive keratoconus (KCN). RECENT FINDINGS: The standard Dresden protocol (SDP) has been utilized clinically since the early 2000 s to treat ectatic disorders, primarily progressive KCN and postrefractive ectasia. Various modifications have since been introduced including accelerated and transepithelial protocols, which are aimed at improving outcomes or reducing complications. This review summarizes data demonstrating that the SDP halts disease progression and improves various visual and topographic indices (UDVA, CDVA, Kmax, K1, K2) up to 13 years postoperatively. Accelerated and transepithelial protocols have been found to be well tolerated alternatives to SDP with similar efficacy profiles. Studies focusing on pediatric populations identified overall higher progression rates after CXL. All protocols reviewed had excellent safety outcomes in adults and children. SUMMARY: Recent studies revealed that SDP successfully stabilizes KCN long term, and a variety of newer protocols are also effective. Pediatric patients may exhibit higher progression rates after CXL. Further research is required to enhance the efficacy and ease of these protocols.


Subject(s)
Collagen , Cross-Linking Reagents , Keratoconus , Photochemotherapy , Photosensitizing Agents , Riboflavin , Visual Acuity , Humans , Keratoconus/drug therapy , Keratoconus/physiopathology , Cross-Linking Reagents/therapeutic use , Photosensitizing Agents/therapeutic use , Riboflavin/therapeutic use , Photochemotherapy/methods , Collagen/therapeutic use , Visual Acuity/physiology , Ultraviolet Rays , Corneal Stroma/metabolism , Corneal Stroma/drug effects , Treatment Outcome , Corneal Topography
14.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741093

ABSTRACT

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Subject(s)
Astigmatism , Corneal Surgery, Laser , Corneal Wavefront Aberration , Myopia , Refraction, Ocular , Visual Acuity , Humans , Myopia/surgery , Myopia/physiopathology , Astigmatism/physiopathology , Astigmatism/etiology , Male , Female , Adult , Visual Acuity/physiology , Corneal Surgery, Laser/methods , Corneal Surgery, Laser/adverse effects , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/etiology , Young Adult , Refraction, Ocular/physiology , Corneal Stroma/surgery , Retrospective Studies , Lasers, Excimer/therapeutic use , Postoperative Complications , Corneal Topography , Adolescent
15.
Transl Vis Sci Technol ; 13(5): 7, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38727695

ABSTRACT

Purpose: Multiple clinical visits are necessary to determine progression of keratoconus before offering corneal cross-linking. The purpose of this study was to develop a neural network that can potentially predict progression during the initial visit using tomography images and other clinical risk factors. Methods: The neural network's development depended on data from 570 keratoconus eyes. During the initial visit, numerical risk factors and posterior elevation maps from Scheimpflug imaging were collected. Increase of steepest keratometry of 1 diopter during follow-up was used as the progression criterion. The data were partitioned into training, validation, and test sets. The first two were used for training, and the latter for performance statistics. The impact of individual risk factors and images was assessed using ablation studies and class activation maps. Results: The most accurate prediction of progression during the initial visit was obtained by using a combination of MobileNet and a multilayer perceptron with an accuracy of 0.83. Using numerical risk factors alone resulted in an accuracy of 0.82. The use of only images had an accuracy of 0.77. The most influential risk factors in the ablation study were age and posterior elevation. The greatest activation in the class activation maps was seen at the highest posterior elevation where there was significant deviation from the best fit sphere. Conclusions: The neural network has exhibited good performance in predicting potential future progression during the initial visit. Translational Relevance: The developed neural network could be of clinical significance for keratoconus patients by identifying individuals at risk of progression.


Subject(s)
Corneal Topography , Deep Learning , Disease Progression , Keratoconus , Keratoconus/diagnostic imaging , Keratoconus/diagnosis , Humans , Female , Male , Adult , Corneal Topography/methods , Young Adult , Risk Factors , Cornea/diagnostic imaging , Cornea/pathology , Adolescent , Middle Aged , Neural Networks, Computer
16.
Sci Rep ; 14(1): 9984, 2024 05 01.
Article in English | MEDLINE | ID: mdl-38693352

ABSTRACT

The aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor), characterized by a lateral resolution of 8.6 µm without requiring any optical element to sample the wavefront information. We evaluated the parameters: root mean square error, Peak-to-Valley, and amplitude of the predominant frequency (Fourier Transform analysis) of a section of the High-Pass filter map in keratoconic and healthy cohorts. Furthermore, we have analyzed keratoconic eyes that presented dark-light bands in this map to assess their period and orientation with the Fourier Transform. There are significant statistical differences (p value < 0.001) between healthy and keratoconic eyes in the three parameters, demonstrating a tendency to increase with the severity of the disease. Otherwise, the quantification of the bands reveals that the width is independent of eye laterality and keratoconic stage as orientation, which tends to be oblique. In conclusion, the quantitative results obtained with t·eyede could help to diagnose and monitor the progression of keratoconus.


Subject(s)
Keratoconus , Keratoconus/diagnostic imaging , Keratoconus/diagnosis , Humans , Adult , Female , Male , Corneal Topography/methods , Young Adult , Aberrometry/methods , Cornea/diagnostic imaging , Cornea/pathology , Fourier Analysis
17.
Vestn Oftalmol ; 140(2. Vyp. 2): 43-50, 2024.
Article in Russian | MEDLINE | ID: mdl-38739130

ABSTRACT

PURPOSE: This study investigates the influence of peripheral corneal thickness (PCT) and its curvature on tonometry readings. MATERIAL AND METHODS: The study included 49 patients (49 eyes) who were indicated for glaucoma surgery. Using bidirectional applanation tonometry, the following parameters were obtained: IOPcc, IOPg - intraocular pressure (IOP) corrected for corneal compensation, taken as the most reliable indicator; IOP converted to Goldmann measurement, taken as the result of applanation tonometry, ΔIOP (IOPcc-IOPg), CH and CRF (corneal hysteresis and corneal resistance factor). During corneal topography, the corneal thickness was studied in the center, PCT at 1.5; 2, 3, 4 and 5 mm from the center in four meridians, as well as ΔPCT (PCT 3 mm - PCT 1.5 mm), the curvature of the anterior and posterior surfaces of the cornea and the depth of the anterior chamber. Aberrometry was used to obtain refractometry data and the curvature of the anterior surface of the cornea. The influence of the studied parameters on ΔIOP was evaluated. RESULTS: ΔIOP correlated with CRF (r= -0.652), CH (r= -0.873), central corneal thickness (r= -0.293), PCT at all distances except 5 mm (r= -0.297; -0.287; -0.302; -0.303), with the strong and weak meridians of the anterior surface of the cornea (r=0.328; r=0.315), with the strong and weak meridians of the posterior surface, as well as the average curvature of the posterior surface (r=0.307; r=0.332; r=0.328). After step-by-step selection of the above parameters for creating a linear regression model for ΔIOP calculation, CH, CRF and PCT1.5mm remained in the model. The model describes ΔIOP with high accuracy (R2=0.974). CONCLUSION: Biomechanical parameters of the cornea are the leading factor of applanation tonometry error. Individual linear dimensions of the cornea (thickness, curvature) have a lesser effect.


Subject(s)
Cornea , Corneal Topography , Glaucoma , Intraocular Pressure , Tonometry, Ocular , Humans , Tonometry, Ocular/methods , Cornea/diagnostic imaging , Intraocular Pressure/physiology , Male , Female , Middle Aged , Corneal Topography/methods , Glaucoma/physiopathology , Glaucoma/diagnosis , Reproducibility of Results , Aged , Adult
18.
J Refract Surg ; 40(4): e218-e228, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38593257

ABSTRACT

PURPOSE: To assess agreement between a new aberrometer (Osiris-T; CSO) employing pyramid wavefront sensor technique and Scheiner-Smirnov aberrometer (OPD-Scan III; Nidek) on measuring ocular, corneal, and internal aberrations in healthy participants. METHODS: The measurements were conducted three times consecutively by an experienced examiner. The total root mean square (RMS) aberrations, higher order aberration RMS, coma Z3±1, trefoil Z3±3, spherical aberration Z40, and astigmatism II Z4±2 up to 7th order were exported in both 4-and 6-mm pupil zones. The parameters between the two devices were statistically compared using the paired t-test, and the differences assessed with Bland-Altman plots and 95% limits of agreement. RESULTS: This prospective study included 70 right eyes of 70 healthy participants with an average age of 25.94 ± 6.59 years (range: 18 to 47 years). The mean difference in the two devices ranged from 0.01 µm for astigmatism II Z4±2 to 0.63 µm for total RMS in 4 mm and from 0.01 to 1.41 µm in 6-mm pupil size. The Bland-Altman analysis of ocular, corneal, and internal aberrations indicated high agreement between the two devices and the maximum absolute values for 95% limits of agreement ranged from 0.03 to 1.06 µm for 4-mm pupil diameters and 0.12 to 1.13 µm for 6-mm pupil diameters. CONCLUSIONS: The newly developed pyramid wavefront sensor technique aberrometer demonstrated a high agreement with a Scheiner-Smirnov aberrometer when measuring ocular, corneal, and internal aberrations in healthy participants. Thus, the two aberrometers may be considered interchangeable for clinical applications. [J Refract Surg. 2024;40(4):e218-e228.].


Subject(s)
Astigmatism , Humans , Young Adult , Adult , Prospective Studies , Cornea , Pupil , Biometry , Corneal Topography , Refraction, Ocular
19.
J Refract Surg ; 40(4): e260-e269, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38593263

ABSTRACT

PURPOSE: To compare the parameters of three different topographic devices (Pentacam HR, Oculus Optikgeräte GmbH; Sirius, Costruzione Strumenti Oftalmici; and Cassini, i-Optics) in grading the severity of keratoconus in cross-linked and non-cross-linked eyes. METHODS: This was a prospective comparative interventional study done in a tertiary eye care center, wherein 114 eyes of 68 patients with keratoconus were divided into two groups: 62 eyes that were observed and 52 eyes that were cross-linked. All eyes were evaluated on all three topographers at baseline, 3-month follow-up, and 6-month follow-up. RESULTS: The Sirius showed significantly lower values of mean flat keratometry in comparison to the Pentacam HR (limits of agreement [LoA]: 1.75 to 3.51%) and Cassini (LoA: 1.75 to 3.51%). The mean steep keratometry values were higher for the Cassini in comparison to the Pentacam HR (LoA: 4.39 to 7.02%) and Sirius (LoA: 3.51 to 6.14%). The mean steep keratometry values of the Sirius were significantly lower than those of the Pentacam HR and in both the cross-linked and observation groups (LoA: 3.51 to 6.14%). The mean keratometry values were significantly higher in the Cassini compared to the Pentacam HR (LoA: 3.51 to 8.77%) and significantly lower in the Sirius in comparison to the Pentacam HR (LoA: 3.51 to 6.14%). The mean difference in astigmatism was also statistically significant between the three tomographers in both groups, with the Cassini showing higher values (LoA: 3.51 to 5.26%) and the Sirius lower values than the Pentacam HR (LoA: 5.26 to 6.14%). CONCLUSIONS: The authors conclude the three devices cannot be used interchangeably. The Cassini showed better agreement and correlation with the Pentacam HR in the staging of keratoconus, whereas the Sirius tended to underdiagnose and under-stage the disease. [J Refract Surg. 2024;40(4):e260-e269.].


Subject(s)
Keratoconus , Humans , Keratoconus/diagnosis , Corneal Topography , Prospective Studies , Reproducibility of Results , Cornea
20.
Int Ophthalmol ; 44(1): 172, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38594548

ABSTRACT

INTRODUCTION: Keratoconus is a progressive disorder of the cornea that causes thinning (Sedaghat et al. in Sci Rep 11(1):11971, 2021), ectasia, and irregular astigmatism, resulting in poor visual acuity that cannot be corrected with standard sphero-cylindrical spectacle lenses. One feature distinguishing keratoconic corneas is ocular aberrations, manifesting up to five or six times the amount of higher-order aberrations than a normal, healthy eye. These aberrations can cause visual disturbances even at the very early stages of the disease. METHODS: In the past, a diagnosis was derived from clinical symptoms, but technological advances have revealed multiple pre-clinical features, allowing for the differentiation between keratoconic and normal eyes at a much earlier stage. These include anterior and posterior corneal surface elevations, the corneal pachymetry profile, corneal epithelial patterns, wavefront aberration metrics, and corneal biomechanics (Sedaghat et al. in Sci Rep 11(1):11971, 2021).This review discusses the aberrations associated with keratoconus, how to measure them, and treatment methods to minimize their negative influence. CONCLUSIONS: Early diagnosis can lead to early treatment and may allow for arresting progression, thereby improving the long-term prognosis. With the acceleration of refractive surgery, it is important to identify patients with keratoconus, as they are usually contraindicated for refractive surgery.


Subject(s)
Astigmatism , Keratoconus , Humans , Keratoconus/diagnosis , Keratoconus/etiology , Keratoconus/therapy , Corneal Topography/methods , Cornea , Astigmatism/diagnosis , Vision Disorders
SELECTION OF CITATIONS
SEARCH DETAIL
...