Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 593
Filter
1.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Article in English | MEDLINE | ID: mdl-38848055

ABSTRACT

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Subject(s)
Corneal Wavefront Aberration , Lens Implantation, Intraocular , Refraction, Ocular , Visual Acuity , Humans , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/etiology , Risk Factors , Visual Acuity/physiology , Refraction, Ocular/physiology , Multifocal Intraocular Lenses , Depth Perception/physiology , Corneal Topography , Cornea/physiopathology
2.
J Refract Surg ; 40(6): e398-e406, 2024 May.
Article in English | MEDLINE | ID: mdl-38848057

ABSTRACT

PURPOSE: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery. METHODS: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire. RESULTS: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers. CONCLUSIONS: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].


Subject(s)
Contrast Sensitivity , Corneal Wavefront Aberration , Depth Perception , Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification , Prosthesis Design , Pseudophakia , Refraction, Ocular , Vision, Binocular , Visual Acuity , Humans , Visual Acuity/physiology , Female , Male , Middle Aged , Aged , Contrast Sensitivity/physiology , Pseudophakia/physiopathology , Refraction, Ocular/physiology , Corneal Wavefront Aberration/physiopathology , Depth Perception/physiology , Vision, Binocular/physiology , Surveys and Questionnaires , Prospective Studies , Patient Satisfaction , Aged, 80 and over , Treatment Outcome
3.
J Refract Surg ; 40(6): e381-e391, 2024 May.
Article in English | MEDLINE | ID: mdl-38848059

ABSTRACT

PURPOSE: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years. METHODS: This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit. RESULTS: At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups. CONCLUSIONS: Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].


Subject(s)
Lens Implantation, Intraocular , Myopia, Degenerative , Phakic Intraocular Lenses , Refraction, Ocular , Visual Acuity , Humans , Visual Acuity/physiology , Refraction, Ocular/physiology , Male , Female , Middle Aged , Adult , Follow-Up Studies , Myopia, Degenerative/physiopathology , Myopia, Degenerative/surgery , Retrospective Studies , Corneal Wavefront Aberration/physiopathology , Rotation
4.
Invest Ophthalmol Vis Sci ; 65(6): 15, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38848076

ABSTRACT

Purpose: The purpose of this study was to investigate the associations between visual function and severity grading, corneal scatter, or higher-order aberrations (HOAs) in patients with Fuchs endothelial corneal dystrophy (FECD). Methods: This observational case series study included 49 eyes of 27 patients with FECD and 10 eyes of 10 healthy individuals. We evaluated corrected distance visual acuity (CDVA) using Landolt-C and Early Treatment Diabetic Retinopathy Study charts and contrast sensitivity using the CSV-1000E chart and CSV-1000RN letter chart. We analyzed the associations between visual function and explanatory variables, including age, modified Krachmer grade, central corneal thickness (CCT), anterior segment optical coherence tomography (AS-OCT)-based grade, HOAs, intraocular straylight, and corneal densitometry. We additionally conducted receiver operating characteristic (ROC) analysis to identify the corneal densitometry thresholds for decreased visual function. Results: There were significant associations between visual function and the modified Krachmer grade, CCT, AS-OCT-based grade, HOAs, intraocular straylight, and corneal densitometry. A modified Krachmer grade ≥ 3 was identified as a threshold for decreased visual function. Multivariate analysis showed that corneal densitometry was significantly associated with all visual function parameters, and HOAs were significantly associated with CDVA but not with contrast sensitivity. ROC analysis revealed that corneal densitometry of the posterior layer at 0 to 2 mm ≥ 10 grayscale units (GSU), was identified as a threshold for decreased visual function. Conclusions: HOAs, forward and backward light scatter affected visual function, with backward light scatter being the most influential. In patients with FECD, modified Krachmer grade ≥ 3 and corneal densitometry ≥ 10 GSU were thresholds for visual disturbance.


Subject(s)
Contrast Sensitivity , Corneal Wavefront Aberration , Fuchs' Endothelial Dystrophy , Scattering, Radiation , Visual Acuity , Humans , Fuchs' Endothelial Dystrophy/physiopathology , Fuchs' Endothelial Dystrophy/diagnosis , Female , Male , Visual Acuity/physiology , Middle Aged , Aged , Contrast Sensitivity/physiology , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/diagnosis , Tomography, Optical Coherence/methods , Cornea/physiopathology , Cornea/diagnostic imaging , Severity of Illness Index , ROC Curve , Aged, 80 and over , Adult
5.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Article in English | MEDLINE | ID: mdl-38717083

ABSTRACT

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Subject(s)
Aberrometry , Astigmatism , Cornea , Corneal Stroma , Corneal Wavefront Aberration , Densitometry , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Corneal Wavefront Aberration/physiopathology , Prospective Studies , Myopia/surgery , Myopia/physiopathology , Adult , Female , Male , Lasers, Excimer/therapeutic use , Visual Acuity/physiology , Corneal Stroma/surgery , Cornea/surgery , Cornea/physiopathology , Young Adult , Refraction, Ocular/physiology , Astigmatism/surgery , Astigmatism/physiopathology , Corneal Surgery, Laser/methods , Corneal Topography
6.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Article in English | MEDLINE | ID: mdl-38717082

ABSTRACT

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Subject(s)
Corneal Stroma , Corneal Topography , Epithelium, Corneal , Hyperopia , Refraction, Ocular , Tomography, Optical Coherence , Visual Acuity , Humans , Hyperopia/surgery , Hyperopia/physiopathology , Prospective Studies , Corneal Stroma/surgery , Corneal Stroma/pathology , Male , Female , Adult , Visual Acuity/physiology , Epithelium, Corneal/surgery , Epithelium, Corneal/pathology , Refraction, Ocular/physiology , Middle Aged , Lasers, Excimer/therapeutic use , Young Adult , Corneal Wavefront Aberration/physiopathology , Corneal Surgery, Laser/methods , Eye Diseases, Hereditary
7.
Vestn Oftalmol ; 140(2): 48-53, 2024.
Article in Russian | MEDLINE | ID: mdl-38742498

ABSTRACT

Purpose. The study investigates corneal and higher-order internal aberrations in patients with amblyopia of different etiologies and their relationship with visual acuity, refraction, axial length, and fixation parameters. MATERIAL AND METHODS: Forty-five patients (90 eyes) were examined. All patients were divided into five groups: 1 - with dysbinocular amblyopia; 2 - with refractive amblyopia; 3 - with anisometropic amblyopia; 4 - with relative amblyopia due to congenital myopia; 5 (control) - fellow eyes without amblyopia. Aberrometry was performed using the OPD-Scan III device (Nidek, Japan). Fixation parameters were studied on the MP-3 microperimeter (Nidek, Japan). Correlation analysis was performed using Pearson's linear correlation coefficient (r). RESULTS: In amblyopia associated with congenital myopia, a significant increase in corneal and internal aberrations RMS, Total HOA, astigmatism (V) (0.65±0.26; 1.01±0.31; 4.22±1.17; -2.17±0.72; 0.86±0.3, respectively; control group - 0.44±0.19; 0.58±0.27; 1.0±0.75; -0.94±0.89; 0.47±0.65) and internal spherical aberration (0.06±0.02; control group - 0.04±0.03) was found. In dysbinocular amblyopia, a significant increase in internal aberrations Trefoil (V) and Coma (H) (0.75±0.52 and 0.17±0.35, respectively; control group - 0.05±0.28 and -0.07±0.21) was found, which correlated with a decrease in fixation density in the 2° ring (r= -0.40, r= -0.41). CONCLUSIONS: The increased level of higher-order aberrations in amblyopia associated with congenital myopia is due to the anatomical and optical features of the eyes. The increase in internal aberrations Trefoil (V) and Coma (H) in dysbinocular amblyopia is associated with a mismatch of the optical elements of the eye due to impaired fixation, i.e., it is not the cause, but the consequence of amblyopia.


Subject(s)
Amblyopia , Myopia , Visual Acuity , Humans , Amblyopia/etiology , Amblyopia/physiopathology , Amblyopia/diagnosis , Male , Child , Female , Myopia/complications , Myopia/physiopathology , Myopia/diagnosis , Refraction, Ocular/physiology , Aberrometry/methods , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/etiology , Corneal Wavefront Aberration/diagnosis
9.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741093

ABSTRACT

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Subject(s)
Astigmatism , Corneal Surgery, Laser , Corneal Wavefront Aberration , Myopia , Refraction, Ocular , Visual Acuity , Humans , Myopia/surgery , Myopia/physiopathology , Astigmatism/physiopathology , Astigmatism/etiology , Male , Female , Adult , Visual Acuity/physiology , Corneal Surgery, Laser/methods , Corneal Surgery, Laser/adverse effects , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/etiology , Young Adult , Refraction, Ocular/physiology , Corneal Stroma/surgery , Retrospective Studies , Lasers, Excimer/therapeutic use , Postoperative Complications , Corneal Topography , Adolescent
11.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38648433

ABSTRACT

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Subject(s)
Collagen , Cornea , Corneal Topography , Cross-Linking Reagents , Keratoconus , Photosensitizing Agents , Riboflavin , Ultraviolet Rays , Visual Acuity , Adolescent , Adult , Female , Humans , Male , Young Adult , Biomechanical Phenomena , Collagen/metabolism , Cornea/diagnostic imaging , Cornea/physiopathology , Cornea/drug effects , Corneal Stroma/metabolism , Corneal Stroma/drug effects , Corneal Wavefront Aberration/physiopathology , Cross-Linking Reagents/therapeutic use , Follow-Up Studies , Keratoconus/drug therapy , Keratoconus/physiopathology , Keratoconus/diagnosis , Photochemotherapy/methods , Photosensitizing Agents/therapeutic use , Prospective Studies , Refraction, Ocular/physiology , Riboflavin/therapeutic use , Visual Acuity/physiology , Child
12.
Cont Lens Anterior Eye ; 47(3): 102133, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38467534

ABSTRACT

BACKGROUND: To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation. METHODS: A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant. RESULTS: Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05). CONCLUSION: Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.


Subject(s)
Accommodation, Ocular , Corneal Wavefront Aberration , Orthokeratologic Procedures , Refraction, Ocular , Visual Acuity , Humans , Male , Female , Accommodation, Ocular/physiology , Prospective Studies , Refraction, Ocular/physiology , Visual Acuity/physiology , Young Adult , Corneal Wavefront Aberration/physiopathology , Corneal Topography , Adult , Myopia/therapy , Myopia/physiopathology , Follow-Up Studies , Adolescent , Contact Lenses
13.
Ophthalmic Physiol Opt ; 44(4): 746-756, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38389207

ABSTRACT

PURPOSE: The goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront-guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well-corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity. METHODS: Building on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront-guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5-mm pupil for the aligned position. The resulting wavefront-guided contact lens was then allowed to translate up to ±1 mm in the x- and y-directions and rotate up ±15°. RESULTS: Allowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected. CONCLUSIONS: Allowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.


Subject(s)
Contact Lenses , Corneal Topography , Keratoconus , Visual Acuity , Humans , Keratoconus/physiopathology , Keratoconus/diagnosis , Corneal Topography/methods , Adult , Female , Male , Visual Acuity/physiology , Young Adult , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/diagnosis , Refraction, Ocular/physiology , Cornea/diagnostic imaging , Cornea/physiopathology
14.
Invest Ophthalmol Vis Sci ; 63(2): 22, 2022 02 01.
Article in English | MEDLINE | ID: mdl-35147660

ABSTRACT

Purpose: To investigate the impact of the size and location of waterclefts (WC), which are one of several cataract subtypes, on visual function by optical simulation analysis. Methods: An optical simulation software (CODE V) was used to develop a schematic eye model and several sizes of WC central and peripheral types that were located below the anterior and posterior subcapsules of the crystalline lens, and analyses of refraction, higher-order aberrations (HOA), and the modulation transfer function (MTF) were performed. Results: An increase in the WC size increased the refraction and HOA and decreased the MTF. The impact of the WC below the posterior subcapsule on the visual function was more enhanced than that below the anterior subcapsule. Large WC demonstrated a remarkable hyperopic shift in refractive power as well as an increase in HOA. The MTF decreased slightly with increasing WC size at a spatial frequency of 20 cycles/mm, and it decreased remarkably at 60 cycles/mm. Conclusions: The impact on the visual function increased with increasing WC size. It was revealed that eyes with WC below the posterior subcapsule are more hyperopic than those with WC below the anterior subcapsule, and the former have a higher HOA and lower MTF than the latter.


Subject(s)
Cataract/physiopathology , Computer Simulation , Refractive Errors/physiopathology , Visual Acuity/physiology , Aged , Cataract/diagnostic imaging , Corneal Wavefront Aberration/physiopathology , Female , Humans , Middle Aged , Refraction, Ocular/physiology
15.
Cornea ; 41(4): 435-442, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-34267059

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the efficacy and safety of implantation of a new continuous corneal ring in keratoconic corneas of an Iranian population. METHODS: This study was conducted on 95 contact lens-intolerant keratoconic eyes with clear central corneas. A continuous corneal ring, annular intrastromal corneal inlay (AICI), was inserted using femtosecond laser in all cases. Patients were followed up for 1, 3, and 12 months postsurgery. Visual and subjective refractive outcomes were evaluated in each examination. Besides, keratometry and aberrometric values were recorded before and 12 months after surgery. Finally, vector analysis of refractive astigmatism was performed using the Alpins method. RESULTS: The uncorrected and corrected distance visual acuities improved significantly 12 months after surgery from 0.91 ± 0.39 to 0.38 ± 0.22 (P < 0 0.001) and 0.33 ± 0.21 to 0.13 ± 0.11 logMAR (P < 0.001), respectively. Moreover, spherical and cylindrical refractive components reduced from -2.52 ± 2.62 to -0.76 ± 1.78 D (P < 0.001) and -4.14 ± 1.64 to -1.91 ± 1.18 D (P < 0.001), respectively. The mean anterior keratometry had a significant reduction 12 months after AICI insertion (P< 0.001). Primary coma and spherical aberration values showed a significant increase (both, P < 0.05). Our results showed 100% safety (safety index: 1.8) and 45% efficacy (efficacy index: 1). CONCLUSIONS: AICI implantation seemed to be a safe and effective procedure for improving visual acuity and refractive outcomes in subjects with keratoconus.


Subject(s)
Corneal Stroma/surgery , Keratoconus/surgery , Prostheses and Implants , Prosthesis Implantation/methods , Aberrometry , Adult , Corneal Topography , Corneal Wavefront Aberration/physiopathology , Female , Follow-Up Studies , Humans , Iran , Keratoconus/physiopathology , Male , Prosthesis Design , Refraction, Ocular/physiology , Treatment Outcome , Visual Acuity/physiology
16.
Cornea ; 40(4): 449-452, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33881810

ABSTRACT

PURPOSE: To determine which baseline characteristics are associated with vision-related quality of life (QOL) after endothelial keratoplasty. METHODS: A patient- and outcome-masked randomized clinical trial. Consecutive patients presenting with isolated endothelial disease requiring endothelial keratoplasty at Oregon Health Sciences University and Stanford University. Study eyes randomized to one of the 2 types of endothelial keratoplasty were given the national eye institute vision function questionnaire 25 at baseline and 12 months. In this prespecified secondary outcome, we assessed the role of recipient and donor characteristics as predictors of the 12-month national eye institute vision function questionnaire 25 change score. RESULTS: The mean vision function questionnaire (VFQ) score was 74 (SD 14) at baseline and increased to 82 (SD 12) at 3 months and 87 (SD 10) at 12 months. We were unable to find a difference in vision-related QOL in study participants who underwent Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping endothelial keratoplasty [coef -0.98, 95% confidence interval (CI) -9.27 to 7.31; P = 0.82]. In multivariable analysis, patients who underwent endothelial keratoplasty in 2 eyes had approximately 8 points higher VFQ at 12 months after the second eye than those who had only one eye enrolled (95% CI 0.10-15.72; P = 0.047). Posterior densitometry produced an approximately 1-point increase each in the VFQ change score for each 1 grayscale unit increase at baseline (95% CI 0.26-1.81; P = 0.009). Although the sample size was small, a diagnosis of pseudophakic bullous keratopathy had approximately 19-points more improvement on average compared with Fuchs (95% CI 7.68-30.00; P = 0.001). CONCLUSIONS: Bilateral endothelial keratoplasty resulted in higher vision-related QOL compared with unilateral. Baseline densitometry, objective measure of corneal haze that predicts vision-related QOL, may play a role in monitoring disease progression.


Subject(s)
Cornea/physiopathology , Corneal Dystrophies, Hereditary/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Quality of Life/psychology , Vision, Ocular/physiology , Visual Acuity/physiology , Aged , Corneal Dystrophies, Hereditary/physiopathology , Corneal Dystrophies, Hereditary/psychology , Corneal Wavefront Aberration/physiopathology , Densitometry , Double-Blind Method , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications , Surveys and Questionnaires , Treatment Outcome
17.
J. optom. (Internet) ; 14(1): 78-85, ene.-mar. 2021. ilus, tab, graf
Article in English | IBECS | ID: ibc-200295

ABSTRACT

PURPOSE: to evaluate the effects of kappa angle and intraocular orientation on the theoretical performance of asymmetric multifocal intraocular lenses (MIOL). METHODS: For a total of 21 corneal aberrations, a computational analysis simulated the implantation of a computationally designed MIOL. An image quality parameter (IQ) (visually modulated transfer function metric) was calculated for a 5.0-mm pupil and for three conditions: distance, intermediate, and near vision. The procedure was repeated for each eye after a rotation of the MIOL with respect to the cornea from 0º to 360º in 5º steps. Kappa angles from 0 to 900 microns, in 150 microns steps, combined with two two variants of MIOL centration were tested: in the corneal apex or in the center of the entrance pupil. A p-value ≤ 0.05 was considered significant. RESULTS: There were statistically significant differences of the IQ depending of the intraocular orientation of the MIOL. If kappa angle was increased, there was a statistically significant decrease of the IQ. The IQ maintained stable when the optimal intraocular orientation was re-calculated for each kappa angle. In general, the inter-variability of the results between subjects was very high. There were no strong evidences supporting that there exists a preferable centration point. CONCLUSIONS: Our results suggest that kappa angle theoretically affects significantly the performance of asymmetric MIOL implantation. However, its negative effect can be compensated if a customized intraocular orientation is calculated taking into account the presence of the kappa angle


No disponible


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Corneal Wavefront Aberration/physiopathology , Multifocal Intraocular Lenses/standards , Patient-Specific Modeling/standards , Case-Control Studies , Prosthesis Design , Corneal Wavefront Aberration/surgery , Corneal Wavefront Aberration/pathology , Reference Values , Medical Illustration , Reproducibility of Results
18.
Optom Vis Sci ; 98(3): 289-294, 2021 03 01.
Article in English | MEDLINE | ID: mdl-33633020

ABSTRACT

SIGNIFICANCE: The SVOne may prove useful to quickly and easily assess refractive correction needs in community screenings and low-resource settings, but not all subjects were testable with the device. PURPOSE: This study aimed to compare the SVOne handheld, smartphone-based wavefront aberrometer with a tabletop autorefractor in identifying refractive errors in elderly subjects. METHODS: Participants 50 years or older at community eye screenings with visual acuity worse than 20/40 in either eye underwent autorefraction followed by two SVOne trials. Power vectors of right eye data were analyzed. RESULTS: Of 84 subjects who underwent autorefraction, 67 (79.8%) were successfully autorefracted with the SVOne, of whom 82.1% (55/67) had a successful repeat reading. Mean M (spherical equivalent) values from tabletop and handheld autorefraction were -0.21 D (95% confidence interval [CI], -0.71 to +0.29 D) and -0.29 D (95% CI, -0.79 to +0.21 D), respectively (P > .05). Mean astigmatism values from tabletop and handheld devices were +1.06 D (95% CI, 0.87 to 1.26 D) and +1.21 D (95% CI, 0.99 to 1.43 D), respectively (P > .05). Intraclass correlation coefficients between devices were 0.95 (95% CI, 0.93 to 0.97) for M, 0.78 (95% CI, 0.66 to 0.86) for J0, and 0.45 (95% CI, 0.24 to 0.63) for J45 (P < .05 for all). Excellent test-retest correlation between SVOne measurements was noted for M (Pearson correlation [r] = 0.96; P < .05), but a weaker correlation was noted for J0 and J45 (r = 0.67 and r = 0.63 [P < .05 for both], respectively). CONCLUSIONS: The SVOne provided strong agreement for M, with the majority of readings within ±1.00 D of each other, when compared with the tabletop autorefractor. A weaker but still good correlation was noted for astigmatism. Similar findings were noted when assessing repeatability.


Subject(s)
Aberrometry/instrumentation , Corneal Wavefront Aberration/diagnosis , Refraction, Ocular/physiology , Refractive Errors/diagnosis , Vision Screening/methods , Aged , Aged, 80 and over , Community Health Services/methods , Corneal Wavefront Aberration/physiopathology , Female , Humans , Male , Middle Aged , Refractive Errors/physiopathology , Reproducibility of Results , Visual Acuity/physiology
19.
Cornea ; 40(9): 1110-1116, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-33591041

ABSTRACT

PURPOSE: To study the change in contrast sensitivities in eyes with Fuchs endothelial dystrophy and bullous keratopathy after Descemet membrane endothelial keratoplasty (DMEK). METHODS: In this prospective study, 50 pseudophakic eyes of 50 patients who received DMEK surgery at the Charité-Universitätsmedizin Berlin were included. Visual acuity; contrast sensitivity using OPTEC 6500 at spatial frequencies of 1.5, 3, 6, 12, and 18 cycles/degree in photopic and mesopic light with and without glare; central corneal thickness (CCT); and anterior and posterior corneal aberrations were measured preoperatively and at 3 and 12 months postoperatively. RESULTS: Best-corrected visual acuity (preoperative 0.67 ± 0.46 and after 12 months 0.19 ± 0.16 LogMAR, P < 0.001) and photopic and mesopic contrast sensitivities with and without glare improved significantly, whereas CCT decreased significantly (preoperative 677 ± 114 µm, after 12 months 527 ± 29 µm, P < 0.001). Preoperative CCT correlates significantly with preoperative photopic contrast sensitivity (correlation coefficient -0.462, P = 0.002), and postoperative total anterior aberrations correlates with postoperative photopic contrast sensitivity (correlation coefficient -0.361, P = 0.006). CONCLUSIONS: Photopic and mesopic contrast sensitivities, especially with glare, are impaired in patients with Fuchs endothelial dystrophy and bullous keratopathy. The extent of the corneal thickening seems to mainly influence the contrast sensitivity preoperatively. DMEK surgery improves the contrast sensitivity significantly. However, higher postoperative anterior corneal aberrations limit the postoperative contrast sensitivities.


Subject(s)
Blister/surgery , Contrast Sensitivity/physiology , Corneal Diseases/surgery , Descemet Stripping Endothelial Keratoplasty , Fuchs' Endothelial Dystrophy/surgery , Aged , Aged, 80 and over , Blister/physiopathology , Cell Count , Color Vision/physiology , Corneal Diseases/physiopathology , Corneal Endothelial Cell Loss/physiopathology , Corneal Wavefront Aberration/physiopathology , Endothelium, Corneal/pathology , Female , Fuchs' Endothelial Dystrophy/physiopathology , Humans , Male , Mesopic Vision/physiology , Postoperative Complications , Postoperative Period , Prospective Studies , Recovery of Function/physiology
20.
Invest Ophthalmol Vis Sci ; 62(2): 15, 2021 02 01.
Article in English | MEDLINE | ID: mdl-33570601

ABSTRACT

Purpose: Keratoconus results in image quality loss in one or both eyes due to increased corneal distortion. This study quantified the depth of monocular suppression in keratoconus due to this image quality loss using a binocular contrast rivalry paradigm. Methods: Contrast rivalry was induced in 50 keratoconic cases (11-31 years) and 12 age-matched controls by dichoptically viewing orthogonal Gabor patches of 5 cycles per degree (cpd) and 1.5 cpd spatial frequency for 120 seconds with their best-corrected spectacles and rigid gas permeable (RGP) contact lenses. The dwell time on each eye's percept was determined at baseline (100% contrast bilaterally) and at varying contrast levels (80-2.5%) in the stronger eye of keratoconus or dominant eye of controls. The contrast reduction needed in the stronger eye to balance dwell times on both eyes was considered a measure of suppression depth. Results: At baseline with 5 cpd stimuli and spectacle correction, the rivalry switches were less frequent and biased toward the stronger eye of cases, all relative to controls (P < 0.001). The contrast balance point of cases (20.51% [10.7-61%]) was lower than the controls (99.80% [98.6-100%]; P < 0.001) and strongly associated with the overall and interocular difference in disease severity (r = 0.83, P < 0.001). The suppression depth reduced for 1.5 cpd (70.8% [21.7-94%]), relative to 5 cpd stimulus (P < 0.001) and with contact lenses (80.1% [49.5-91.7%]), relative to spectacles (P < 0.001). Conclusions: The eye with lesser disease severity dominates binocular viewing in keratoconus. The suppression depth of the poorer eye depends on the extent of bilateral disease severity, optical correction modality, and the target spatial frequency.


Subject(s)
Cornea/diagnostic imaging , Corneal Wavefront Aberration/physiopathology , Keratoconus/physiopathology , Vision, Binocular/physiology , Visual Acuity , Adolescent , Adult , Child , Contact Lenses , Corneal Wavefront Aberration/diagnosis , Eyeglasses , Female , Humans , Keratoconus/diagnosis , Keratoconus/therapy , Male , Severity of Illness Index , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...