Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.073
Filter
1.
BMC Cardiovasc Disord ; 24(1): 234, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702615

ABSTRACT

BACKGROUND: Insulin resistance (IR) can lead to cellular metabolic disorders, activation of oxidative stress, and endothelial dysfunction, contributing to in-stent restenosis (ISR). The triglyceride-glucose index (TyG index), a new indicator reflecting IR, is extensively researched in the cardiovascular field. This study, through a meta-analysis, aimed to utilize a larger combined sample size and thereby enhance the overall test efficacy to explore the TyG index-ISR relationship. METHODS: A thorough search was conducted in the PubMed, EMBASE, Web of Science, and Cochrane Library databases to find original papers and their references published between 1990 and January 2024. This search included both prospective and retrospective studies detailing the correlation between the TyG index and ISR in individuals with coronary heart disease (CHD). OUTCOMES: The five included articles comprised 3,912 participants, and the odds ratio (OR) extracted from each study was combined using the Inverse Variance method. Results showed that, in the context of CHD patients, each incremental unit in the TyG index, when treated as a continuous variable, corresponded to a 42% elevation in ISR risk (95% CI 1.26-1.59, I²=13%, p < 0.005). When analyzing the TyG index categorically, the results revealed a higher ISR risk in the highest TyG index group compared to the lowest group (OR: 1.69, 95% CI 1.32-2.17, I²=0). Additionally, in patients with chronic coronary syndrome (CCS), each unit increase in the TyG index, the risk of ISR in patients increased by 37% (95% CI 1.19-1.57, I²=0%, p < 0.005). This correlation was also observable in acute coronary syndrome (ACS) patients (OR:1.48, 95% CI 1.19-1.85, I²=0, p < 0.005). CONCLUSIONS: The TyG index, an economical and precise surrogate for IR, is significantly linked with ISR. Furthermore, this correlation is unaffected by the type of coronary heart disease.


Subject(s)
Biomarkers , Blood Glucose , Coronary Artery Disease , Coronary Restenosis , Insulin Resistance , Percutaneous Coronary Intervention , Stents , Triglycerides , Humans , Biomarkers/blood , Blood Glucose/metabolism , Coronary Artery Disease/blood , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnosis , Coronary Restenosis/blood , Coronary Restenosis/etiology , Coronary Restenosis/diagnosis , Coronary Restenosis/diagnostic imaging , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Risk Assessment , Risk Factors , Treatment Outcome , Triglycerides/blood
2.
Medicina (Kaunas) ; 60(4)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38674195

ABSTRACT

Despite ongoing progress in stent technology and deployment techniques, in-stent restenosis (ISR) still remains a major issue following percutaneous coronary intervention (PCI) and accounts for 10.6% of all interventions in the United States. With the continuous rise in ISR risk factors such as obesity and diabetes, along with an increase in the treatment of complex lesions with high-risk percutaneous coronary intervention (CHIP), a substantial growth in ISR burden is expected. This review aims to provide insight into the mechanisms, classification, and management of ISR, with a focus on exploring innovative approaches to tackle this complication comprehensively, along with a special section addressing the approach to complex calcified lesions.


Subject(s)
Coronary Restenosis , Percutaneous Coronary Intervention , Stents , Humans , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Coronary Restenosis/etiology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/therapy , Stents/adverse effects , Risk Factors , Ultrasonography, Interventional/methods
5.
Catheter Cardiovasc Interv ; 103(4): 532-538, 2024 03.
Article in English | MEDLINE | ID: mdl-38415895

ABSTRACT

BACKGROUND: Studies evaluating the safety and efficacy of drug coating balloons (DCB) for the treatment of lesions in large coronary vessel are limited. AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries. METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality. RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003). CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.


Subject(s)
Coronary Artery Disease , Coronary Restenosis , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Sirolimus/adverse effects , Treatment Outcome , Coronary Angiography , Coated Materials, Biocompatible
6.
Int J Cardiovasc Imaging ; 40(4): 699-708, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38416297

ABSTRACT

The morphological characteristics of in-stent restenosis (ISR) in relation to varying degrees of area stenosis have not been comprehensively examined. This study aimed to explore the tissue characteristics of patients experiencing ISR with different degrees of area stenosis through the utilization of optical coherence tomography (OCT). In total, 230 patients with ISR who underwent OCT were divided into the following three groups: area stenosis (AS) < 70% (n = 26); 70-80% (n = 119) and AS ≥ 80% (n = 85). Among the 230 patients, the clinical presentation as stable angina was 61.5% in AS < 70%, followed by 47.2% in 70% < AS ≤ 80%, and 31.8% in AS ≥ 80% (P = 0.010). The OCT findings showed that heterogeneous neointima, ISNA, LRP, neointima rupture, TCFA-like pattern, macrophage infiltration, red and white thrombus was more common with AS increased. Ordinal logistic regression analysis showed that higher AS was associated with previous dyslipidemia (odds ratio [OR], 4.754; 95% confidence interval [CI], 1.419-15.927, P = 0.011), neointimal rupture (OR: 3.640; 95% CI, 1.169-11.325, P = 0.026), red thrombus (OR: 4.482; 95% CI, 1.269-15.816, P = 0.020) and white thrombus (OR: 5.259; 95% CI, 1.660-16.659, P = 0.005). Patients with higher degrees of area stenosis in the context of ISR exhibited a greater number of discernible morphological characteristics as identified through OCT analysis. Furthermore, previous dyslipidemia, neointimal rupture, white thrombus and red thrombus were highly associated with and the progression of ISR lesions.


Subject(s)
Coronary Restenosis , Coronary Vessels , Neointima , Percutaneous Coronary Intervention , Predictive Value of Tests , Severity of Illness Index , Stents , Tomography, Optical Coherence , Humans , Male , Female , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/pathology , Middle Aged , Aged , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Risk Factors , Treatment Outcome , Retrospective Studies , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/pathology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/pathology , Coronary Stenosis/therapy , Rupture, Spontaneous
7.
Comput Biol Med ; 171: 108128, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38342047

ABSTRACT

Stent implantation is a principal therapeutic approach for coronary artery diseases. Nonetheless, the presence of stents significantly interferes with in-stent luminal (ISL) visualization and complicates the diagnosis of in-stent restenosis (ISR), thereby increasing the risk of misdiagnoses and underdiagnoses in coronary computed tomography angiography (CCTA). Dual-energy (DE) CT could calculate the volume fraction for voxels from low- and high-energy images (LHEI) and provide information on specific three basic materials. In this study, the innovative coronary stent decomposition algorithm (CSDA) was developed from the DECT three materials decomposition (TMD), through spectral simulation to determine the scan and attenuation coefficient for the stent, and preliminary execution for an in vitro sophisticated polyether ether ketone (PEEK) 3D-printed right coronary artery (RCA) replica. Furthermore, the whole-coronary-artery replica with multi-stent implantation, the RCA replica with mimetic plaque embedded, and two patients with stent further validated the effectiveness of CSDA. Post-CSDA images manifested no weakened attenuation values, no elevated noise values, and maintained anatomical integrity in the coronary lumen. The stents were effectively removed, allowing for the ISL and ISR to be clearly visualized with a discrepancy in diameters within 10%. We believe that CSDA presents a promising solution for enhancing CCTA diagnostic accuracy post-stent implantation.


Subject(s)
Computed Tomography Angiography , Coronary Restenosis , Humans , Computed Tomography Angiography/methods , Coronary Angiography/methods , Tomography, X-Ray Computed/methods , Stents , Algorithms , Coronary Restenosis/diagnostic imaging
8.
Catheter Cardiovasc Interv ; 103(3): 404-416, 2024 02.
Article in English | MEDLINE | ID: mdl-38214114

ABSTRACT

BACKGROUND: Some clinical trials have verified the efficacy and safety of paclitaxel drug-coated balloon (DCB) for small vessel coronary artery disease. However, nonsmall vessel and calcified lesions received less attention. AIMS: This study aimed to investigate the efficacy of DCB treatment for various types of coronary artery lesions, including not only small vessel disease but also nonsmall vessel disease and calcified lesions. In this real-world clinical practice study, in-stent restenosis was excluded. METHODS: This study consecutively included 934 patients with 1751 nonstented lesions who received DCB at a cardiovascular center in Kyoto Katsura Hospital in Japan between 2009 and 2012 and 2014 to 2019. This study enrolled and retrospectively analyzed all of the patients. Eligible patients routinely underwent follow-up angiography at 6-8 months after percutaneous coronary intervention. The primary endpoint includes target lesion revascularization (TLR) during follow-up. Further, this study calculated the predictor of TLR using multivariate analysis. RESULTS: This study included the lesions involving 46.4% of type B2/C, 26.9% with severe calcification, and 6.0% with DCB restenosis. Mean DCB diameter and length were 2.75 ± 0.51 mm and 24.2 ± 9.6 mm, respectively. The median follow-up duration was 18 months. Follow-up angiography revealed a TLR rate of 9% and a restenosis rate of 9%. This study identified hemodialysis and current smoking as independent TLR predictors. CONCLUSION: In routine clinical practice, the effectiveness of DCB was observed consistently across various types of coronary artery disease.


Subject(s)
Coronary Artery Disease , Coronary Restenosis , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Retrospective Studies , Treatment Outcome , Percutaneous Coronary Intervention/adverse effects , Paclitaxel/adverse effects , Constriction, Pathologic , Coated Materials, Biocompatible , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Angiography
9.
Coron Artery Dis ; 35(3): 209-214, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38180335

ABSTRACT

OBJECTIVE: This study aims to assess the predictive value of the Systemic Immune Inflammation Index (SII) in determining in-stent restenosis (ISR) likelihood in patients with acute coronary syndrome (ACS) who have undergone percutaneous coronary intervention (PCI). METHODS: The study enrolled 903 ACS patients undergoing PCI, categorized into ISR (+) and ISR (-) groups based on control coronary angiography results. Demographic, clinical, laboratory, and angiographic-procedural characteristics were systematically compared. RESULTS: The ISR (+) group encompassed 264 individuals (29.2%), while the ISR (-) group comprised 639 individuals (70.8%). Patients had a mean age of 55.8 ±â€…10.2 years, with 69% being male. The ISR (+) group had higher diabetes and smoking prevalence and notably larger stent dimensions. Lab parameters showed significantly elevated creatinine, total cholesterol, red cell distribution width, white blood cell and neutrophil counts, SII index and C-reactive protein (CRP) in the ISR (+) group, while lymphocyte levels were lower. Binary logistic regression identified stent diameter (odds ratio [OR]: 0.598, 95% confidence interval [CI]: 0.383-0.935; P  = 0.024), stent length (OR: 1.166, 95% CI: 1.132-1.200; P  < 0.001), creatinine (OR: 0.366, 95% CI: 0.166-0.771; P  = 0.003), CRP (OR: 1.075, 95% CI: 1.042-1.110; P  = 0.031), and SII index (OR: 1.014, 95% CI: 1.001-1.023; P  < 0.001) as independent ISR predictors. CONCLUSION: The SII index exhibits potential as a predictive marker for ISR in ACS patients post-PCI, indicating systemic inflammation and heightened restenosis risk. Integrating the SII index into risk models could identify high-risk patients for targeted interventions.


Subject(s)
Acute Coronary Syndrome , Coronary Restenosis , Percutaneous Coronary Intervention , Humans , Male , Middle Aged , Aged , Female , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Risk Factors , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/etiology , Creatinine , Coronary Angiography/adverse effects , Stents/adverse effects , C-Reactive Protein/analysis , Inflammation , Constriction, Pathologic , Retrospective Studies
10.
BMC Cardiovasc Disord ; 24(1): 32, 2024 01 06.
Article in English | MEDLINE | ID: mdl-38184550

ABSTRACT

BACKGROUND: Antiphospholipid antibody syndrome (APS) is a multisystemic autoimmune disorder which affects many organs or systems; however, coronary artery is relatively less frequently involved. CASE PRESENTATION: A 65-year-old female with effort chest pain was hospitalized for unstable angina in Janurary, 2015. Coronary angiography revealed sub-total occlusion of proximal left anterior descending (LAD) coronary artery, where a drug-eluting stent was successfully deployed. The patient experienced multiple in-stent stenosis at LAD coronary artery and coronary artery bypass graft (CABG) surgery was advised. Subsequently, severe stenosis of left circumflex (LCX) coronary artery emerged, and the patient suffered persistent in-stent restenosis. Eventually, the patient was diagnosed with seronegative antiphospholipid antibody syndrome and salvaged by immunosuppressants. CONCLUSIONS: Repeated in-stent restenosis could be a primary manifestation of seronegative antiphospholipid antibody syndrome, and suppression of autoimmune activity and inflammation other than purely coronary revascularization might be a better option.


Subject(s)
Antiphospholipid Syndrome , Coronary Occlusion , Coronary Restenosis , Drug-Eluting Stents , Female , Humans , Aged , Antiphospholipid Syndrome/complications , Antiphospholipid Syndrome/diagnosis , Antiphospholipid Syndrome/therapy , Coronary Vessels , Constriction, Pathologic , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Coronary Angiography
11.
Catheter Cardiovasc Interv ; 103(2): 260-267, 2024 02.
Article in English | MEDLINE | ID: mdl-38173300

ABSTRACT

BACKGROUND: Among patients undergoing percutaneous coronary intervention (PCI), in-stent restenosis (ISR) is related with a worse prognosis, while higher body mass index (BMI) values are associated with better outcomes. It is unclear whether the prognostic impact of ISR varies in function of BMI. METHODS: Patients undergoing PCI at a large center from 2012 to 2019 not presenting with an acute myocardial infarction (MI) were included. Subjects with BMI < 18.5 kg/m2 or treated with bare metal stents were excluded. Patients were stratified according to type of lesion treated (ISR vs. no-ISR) and into four BMI categories: normal weight (BMI 18.5-25 kg/m2 ), overweight (25.0-29.9 kg/m2 ), class I obesity (30.0-34.9 kg/m2 ), class II-III obesity (≥35.0 kg/m2 ). The primary outcome was major adverse cardiovascular events (MACE), a composite of all-cause death, MI, and target vessel revascularization (TVR) at 1 year. RESULTS: Out of 16,234 patients, 3694 (23%) underwent PCI for ISR. ISR as compared to no-ISR was associated with a consistent increased risk of MACE within the normal weight (18.8% vs. 7.8%, adj. hazard ratio (HR): 1.99, 95% confidence interval [CI]: 1.51-2.64), overweight (19.1% vs. 6.4%, adj. HR: 2.35, 95% CI: 1.91-2.88), class I obesity (18.3% vs. 6.8%, adj. HR: 1.95, 95% CI: 1.47-2.57), and class II-III obesity (16.4% vs. 7.4%, adj. HR: 1.61, 95% CI: 1.09-2.37) groups (interaction p-value: 0.192). The ISR-related risks were mostly driven by an excess of TVR. CONCLUSIONS: At 1 year, ISR was associated with an increased risk of MACE irrespective of BMI, mostly due to an excess of TVR after ISR.


Subject(s)
Coronary Restenosis , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Percutaneous Coronary Intervention/adverse effects , Prognosis , Overweight/complications , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Risk Factors , Drug-Eluting Stents/adverse effects , Treatment Outcome , Obesity/complications , Obesity/diagnosis , Coronary Angiography/adverse effects
12.
Angiology ; 75(2): 122-130, 2024 Feb.
Article in English | MEDLINE | ID: mdl-36607632

ABSTRACT

Coronary in-stent restenosis (ISR) remains a challenge in interventional cardiology. We investigated the relationship between angiographic pre-interventional grade of lesion stenosis (LS) and the prognosis of late ISR. After exclusions, 110 patients with ISR and 109 patients without ISR were compared. In the ISR group, the grade of LS was greater (P < .001) and the length of the critical segment (LCS) was longer (P < .001). Stent length was longer in the ISR group (P = .008). Compared with the LCS, the grade of LS above 87.5% is 6.9 times more predictive of ISR than the LCS >10.5 mm. Kaplan-Meier curve analysis showed that the grade of initial LS >87.5% had a higher ISR rate than the grade of LS <87.5% (log-rank test P < .001) and critical lesion length over 10.5 mm had a higher ISR rate than critical lesion length under 10.5 mm (log-rank test P < .001). The present study found that the angiographic pre-interventional grades of LS and LCS were important predictors of ISR. Pre-interventional angiographic stenosis >87.5% was significantly predictive of late ISR.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis , Humans , Angioplasty, Balloon, Coronary/methods , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Constriction, Pathologic , Coronary Vessels , Stents , Coronary Angiography , Treatment Outcome
13.
Curr Probl Cardiol ; 49(2): 102212, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37993007

ABSTRACT

BACKGROUND: The importance of coronary computerized tomography angiography (CCTA) in detecting native coronary artery stenosis has been established. However, very few studies investigated the efficacy of CCTA in the assessment of in-stent restenosis (ISR) in symptomatic patients after percutaneous coronary intervention (PCI). AIM OF THE STUDY: To evaluate the value of CCTA in diagnosing ISR. METHODS: We included 102 symptomatic patients with stable angina, presented one to five years after PCI. All patients were subjected to CCTA, and the patients with significant coronary artery disease were directed for invasive coronary angiography (ICA). CCTA results were compared to ICA as the gold standard tool for detecting ISR. RESULTS: In 88 (86.3 %) patients, CCTA could successfully exclude ISR together with the ICA (true negative), but in two cases, ICA detected an ISR which was not detected by CCTA (false negative). In eight patients, CCTA detected ISR. These were confirmed by ICA (true positive) and revascularized. In four patients (3.9 %), ISR was suspected by CCTA but excluded by ICA (false positive). In our study, according to the agreement of CCTA in detection or exclusion of ISR, sensitivity, specificity, PPV, NPV and accuracy were 80.0 %, 96.65 %, 66.67 %, 97.78 %, 94.12 %, respectively. These results were statistically significant (P < 0.001). CONCLUSIONS: In up to 86 % of symptomatic patients with previous PCI, ISR was accurately excluded by CCTA. CCTA was demonstrated by this study as a high yielding tool for ruling out ISR, abolishing the need for more invasive and expensive diagnostic procedures.


Subject(s)
Coronary Artery Disease , Coronary Restenosis , Coronary Stenosis , Percutaneous Coronary Intervention , Humans , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Tomography, X-Ray Computed , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Predictive Value of Tests
14.
Eur Radiol ; 34(4): 2647-2657, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37672056

ABSTRACT

OBJECTIVES: Evaluation of in-stent restenosis (ISR), especially for small stents, remains challenging during computed tomography (CT) angiography. We used deep learning reconstruction to quantify stent strut thickness and lumen vessel diameter at the stent and compared it with values obtained using conventional reconstruction strategies. METHODS: We examined 166 stents in 85 consecutive patients who underwent CT and invasive coronary angiography (ICA) within 3 months of each other from 2019-2021 after percutaneous coronary intervention with coronary stent placement. The presence of ISR was defined as percent diameter stenosis ≥ 50% on ICA. We compared a super-resolution deep learning reconstruction, Precise IQ Engine (PIQE), and a model-based iterative reconstruction, Forward projected model-based Iterative Reconstruction SoluTion (FIRST). All images were reconstructed using PIQE and FIRST and assessed by two blinded cardiovascular radiographers. RESULTS: PIQE had a larger full width at half maximum of the lumen and smaller strut than FIRST. The image quality score in PIQE was higher than that in FIRST (4.2 ± 1.1 versus 2.7 ± 1.2, p < 0.05). In addition, the specificity and accuracy of ISR detection were better in PIQE than in FIRST (p < 0.05 for both), with particularly pronounced differences for stent diameters < 3.0 mm. CONCLUSION: PIQE provides superior image quality and diagnostic accuracy for ISR, even with stents measuring < 3.0 mm in diameter. CLINICAL RELEVANCE STATEMENT: With improvements in the diagnostic accuracy of in-stent stenosis, CT angiography could become a gatekeeper for ICA in post-stenting cases, obviating ICA in many patients after recent stenting with infrequent ISR and allowing non-invasive ISR detection in the late phase. KEY POINTS: • Despite CT technology advancements, evaluating in-stent stenosis severity, especially in small-diameter stents, remains challenging. • Compared with conventional methods, the Precise IQ Engine uses deep learning to improve spatial resolution. • Improved diagnostic accuracy of CT angiography helps avoid invasive coronary angiography after coronary artery stenting.


Subject(s)
Coronary Restenosis , Deep Learning , Humans , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Restenosis/diagnostic imaging , Feasibility Studies , Constriction, Pathologic , Tomography, X-Ray Computed/methods , Stents
16.
JACC Cardiovasc Interv ; 17(1): 1-13, 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-37902151

ABSTRACT

BACKGROUND: Treatment of patients with recurrence of in-stent restenosis (ISR) remains particularly challenging, with data and guideline recommendations for repeat percutaneous coronary intervention being scant. OBJECTIVES: The aim of this study was to investigate the long-term incidence of recurrent revascularization events after percutaneous treatment of drug-eluting stent (DES) ISR. METHODS: In this post hoc analysis, 402 patients (500 lesions) assigned to plain balloon (PB), drug-coated balloon (DCB), or DES treatment in the randomized ISAR-DESIRE 3 (Efficacy Study of Paclitaxel-Eluting Balloon, -Stent vs. Plain Angioplasty for Drug-Eluting Stent Restenosis) trial were followed up over a median of 10.3 years. The primary endpoint was total repeat target lesion revascularization (R-TLR) including all, first and recurrent, events. RESULTS: At the end of follow-up, first R-TLR was required in 204 lesions, 82 in the PB group, 70 in the DCB group, and 52 in the DES group. The total number of R-TLRs was 373: 162 in the PB group, 124 in the DCB group, and 87 in the DES group. During the first year of follow-up, the risk for total R-TLR was reduced by DCB (HR: 0.36; 95% CI: 0.24-0.54) and DES (HR: 0.23; 95% CI: 0.14-0.38) treatment compared with PB treatment. After 1 year, the risk for total R-TLR was nonsignificantly reduced by DCB treatment (HR: 0.77; 95% CI: 0.51-1.16) and significantly reduced by DES treatment (HR: 0.61; 95% CI: 0.39-0.95) compared with PB treatment. Risk in the DCB and DES groups was similar during (HR: 1.54; 95% CI: 0.89-2.69) and after (HR: 1.26; 95% CI: 0.82-1.92) 1 year. CONCLUSIONS: The total number of R-TLRs over 10 years after treatment of patients with DES ISR was high. DCBs and particularly DES were able to reduce the need for both first and recurrent revascularization compared with PB treatment.


Subject(s)
Coronary Restenosis , Drug-Eluting Stents , Humans , Angioplasty, Balloon, Coronary , Coated Materials, Biocompatible , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Drug-Eluting Stents/adverse effects , Paclitaxel , Percutaneous Coronary Intervention , Treatment Outcome , Randomized Controlled Trials as Topic
18.
Cardiovasc Diabetol ; 22(1): 337, 2023 12 08.
Article in English | MEDLINE | ID: mdl-38066597

ABSTRACT

BACKGROUND: Subjects with type 2 diabetes (T2D) have a higher risk of in-stent restenosis and stent thrombosis. The activation of the glucagon-like peptide-1 receptor (GLP-1R) has been suggested to induce several effects on the vasculature that may reduce the risk of stent failure following an angioplasty. The aim of this study is to evaluate the effect of the GLP-1R agonist exenatide on endothelialization of a modern drug-eluting stent (DES) in subjects with T2D. METHODS: 38 subjects with T2D who were eligible for revascularization with implantation of DES were randomized to treatment with exenatide (once weekly) plus standard treatment, or to standard treatment alone. After 12 weeks, a new coronary angiography was performed to evaluate the percentage of strut coverage (primary endpoint) and the presence of neo-atherosclerosis by optical coherence tomography. This study was approved by the Stockholm's Ethical Review Board. RESULTS: The two groups were well balanced regarding baseline clinical characteristics. Strut coverage was 95% (88.7-98.5%) in the exenatide group and 91.4% (88.8-98.5%) in the control group (p = 0.692). There were no significant differences between groups neither in the thickness of neo-intima (0.2 mm in both groups, p = 0.471), nor the maximal in-stent obstruction by neo-intima (15.5% in exenatide group vs 14.7% in control group, p = 0.801). No significant differences were detected in the rate of target lesion revascularization between groups (p = 0.224). CONCLUSION: Twelve weeks treatment with exenatide did not lead to a significantly better stent coverage in people with T2D. No significant differences in the occurrence of neo-atherosclerosis were detected between groups. TRIAL REGISTRATION: The study was registered at www. CLINICALTRIALS: gov (Rebuild Study, NCT02621489).


Subject(s)
Diabetes Mellitus, Type 2 , Exenatide , Percutaneous Coronary Intervention , Humans , Atherosclerosis/pathology , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/pathology , Coronary Vessels/pathology , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/drug therapy , Diabetes Mellitus, Type 2/pathology , Drug-Eluting Stents , Exenatide/therapeutic use , Stents , Tomography, Optical Coherence/methods , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 102(7): 1238-1257, 2023 12.
Article in English | MEDLINE | ID: mdl-37948409

ABSTRACT

Drug-coated balloons (DCB) offer an excellent alternative to stents as the antiproliferative drugs are delivered via balloons and hence there is no permanent implant of metal or polymer. This rationale applies perfectly in in-stent restenosis (ISR) as we want to avoid another layer of metal in a previously failed stent. However, their use has also been extended to de novo lesions especially in patients and lesion subsets where stents are not ideal. There is an increased desire toward expanding this further and studies are now being done which are testing DCB in large-caliber vessels. As the use of DCB is escalating, we felt the importance of writing this article whereby we aim to provide important tips and tricks when using DCB especially for the operators who are in the early phase or have the desire of embarking this technology. From our experience, the DCB-angioplasty substantially differs on several aspects from DES-angioplasty. We have provided several case bases examples including algorithm when using DCB in ISR and de novo lesions.


Subject(s)
Angioplasty, Balloon, Coronary , Angioplasty, Balloon , Coronary Restenosis , Drug-Eluting Stents , Humans , Treatment Outcome , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon/adverse effects , Stents , Coated Materials, Biocompatible , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Paclitaxel
SELECTION OF CITATIONS
SEARCH DETAIL
...