1.
Eur Rev Med Pharmacol Sci ; 28(9): 3391-3402, 2024 May.
Article in English | MEDLINE | ID: mdl-38766802

ABSTRACT

OBJECTIVE: Although pure titanium (PT) and its alloys exhibit excellent mechanical properties, they lack biological activity as implants. The purpose of this study was to improve the biological activity of titanium implants through surface modification. MATERIALS AND METHODS: Titanium was processed into titanium discs, where the titanium discs served as anodes and stainless steel served as cathodes, and a copper- and cobalt-doped porous coating [pure titanium model (PTM)] was prepared on the surface of titanium via plasma electrolytic oxidation. The surface characteristics of the coating were evaluated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and profilometry. The corrosion resistance of PTM was evaluated with an electrochemical workstation. The biocompatibility and bioactivity of coated bone marrow mesenchymal stem cells (BMSCs) were evaluated through in vitro cell experiments. RESULTS: A copper- and cobalt-doped porous coating was successfully prepared on the surface of titanium, and the doping of copper and cobalt did not change the surface topography of the coating. The porous coating increased the surface roughness of titanium and improved its resistance to corrosion. In addition, the porous coating doped with copper and cobalt promoted the adhesion and spreading of BMSCs. CONCLUSIONS: A porous coating doped with copper and cobalt was prepared on the surface of titanium through plasma electrolytic oxidation. The coating not only improved the roughness and corrosion resistance of titanium but also exhibited good biological activity.


Subject(s)
Coated Materials, Biocompatible , Cobalt , Copper , Mesenchymal Stem Cells , Surface Properties , Titanium , Titanium/chemistry , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Mesenchymal Stem Cells/drug effects , Copper/chemistry , Porosity , Cobalt/chemistry , Animals , Corrosion , Materials Testing , Cells, Cultured , Prostheses and Implants
2.
BMC Oral Health ; 24(1): 564, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745154

ABSTRACT

BACKGROUND: Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting clinical progress and outcome. Numerous studies have confirmed the correlation between alloy corrosion and raised surface roughness, which has a direct impact on the working characteristics of orthodontic archwires. METHODS: Thirty nickel-titanium (NiTi) orthodontic archwires were utilized in this study. Patients were randomly selected and allocated into three groups according to the randomization plan; (The control group): subjects practiced regular oral hygiene; (The fluoride group): subjects used fluoride for intensive prophylaxis; (The chlorhexidine group): subjects used chlorhexidine. Representative samples were evaluated by SEM, and then SEM images with high resolution were examined using Image J software to determine the surface roughness and obtain the results for further statistical analysis. RESULTS: Our findings indicated a significant difference was found between the three groups regarding the anterior and posterior parts between the control and the two other groups and a non-significant difference between NaF and CHX groups. Overall, the p-value for group comparisons was 0.000 for both parts, indicating a highly significant difference especially between the control and NaF groups. CONCLUSION: Mouthwashes containing sodium fluoride demonstrated more significant surface alterations than the control and CHX groups and should be prescribed in accordance with orthodontic materials to reduce side effects.


Subject(s)
Alloys , Chlorhexidine , Dental Alloys , Microscopy, Electron, Scanning , Nickel , Orthodontic Wires , Sodium Fluoride , Surface Properties , Humans , Sodium Fluoride/therapeutic use , Chlorhexidine/therapeutic use , Corrosion , Dental Alloys/chemistry , Nickel/chemistry , Titanium/chemistry , Cariostatic Agents/therapeutic use , Cariostatic Agents/chemistry , Male , Female , Young Adult , Mouthwashes/therapeutic use , Mouthwashes/chemistry , Image Processing, Computer-Assisted/methods , Adolescent , Adult , Oral Hygiene
3.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38725023

ABSTRACT

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Subject(s)
Dielectric Spectroscopy , Materials Testing , Orthodontic Wires , Saliva, Artificial , Stainless Steel , Zinc , Corrosion , Stainless Steel/chemistry , Zinc/chemistry , Saliva, Artificial/chemistry , Dental Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Fluorides/chemistry , Hydrogen-Ion Concentration , Humans , Surface Properties , Potentiometry
4.
J Environ Manage ; 359: 121107, 2024 May.
Article in English | MEDLINE | ID: mdl-38728984

ABSTRACT

Microbial induced concrete corrosion (MICC) is the primary deterioration affecting global sewers. Disentangling ecological mechanisms in the sewer system is meaningful for implementing policies to protect sewer pipes using trenchless technology. It is necessary to understand microbial compositions, interaction networks, functions, alongside assembly processes in sewer microbial communities. In this study, sewer wastewater samples and microbial samples from the upper part (UP), middle part (MP) and bottom part (BP) of different pipes were collected for 16S rRNA gene amplicon analysis. It was found that BP harbored distinct microbial communities and the largest proportion of unique species (1141) compared to UP and MP. The community in BP tended to be more clustered. Furthermore, significant differences in microbial functions existed in different spatial locations, including the carbon cycle, nitrogen cycle and sulfur cycle. Active microbial sulfur cycling indicated the corrosion risk of MICC. Among the environmental factors, the oxidation‒reduction potential drove changes in BP, while sulfate managed changes in UP and BP. Stochasticity dominated community assembly in the sewer system. Additionally, the sewer microbial community exhibited numerous positive links. BP possessed a more complex, modular network with higher modularity. These deep insights into microbial ecology in the sewer system may guide engineering safety and disaster prevention in sewer infrastructure.


Subject(s)
Sewage , Sewage/microbiology , RNA, Ribosomal, 16S/genetics , Wastewater/microbiology , Ecology , Corrosion , Microbiota
5.
Int J Mol Sci ; 25(10)2024 May 13.
Article in English | MEDLINE | ID: mdl-38791360

ABSTRACT

Overly fast corrosion degradation of biodegradable magnesium alloys has been a major problem over the last several years. The development of protective coatings by using biocompatible, biodegradable, and non-toxic material such as chitosan ensures a reduction in the rate of corrosion of Mg alloys in simulated body fluids. In this study, chitosan/TiO2 nanocomposite coating was used for the first time to hinder the corrosion rate of Mg19Zn1Ca alloy in Hank's solution. The main goal of this research is to investigate and explain the corrosion degradation mechanism of Mg19Zn1Ca alloy coated by nanocomposite chitosan-based coating. The chemical composition, structural analyses, and corrosion tests were used to evaluate the protective properties of the chitosan/TiO2 coating deposited on the Mg19Zn1Ca substrate. The chitosan/TiO2 coating slows down the corrosion rate of the magnesium alloy by more than threefold (3.6 times). The interaction of TiO2 (NPs) with the hydroxy and amine groups present in the chitosan molecule cause their uniform distribution in the chitosan matrix. The chitosan/TiO2 coating limits the contact of the substrate with Hank's solution.


Subject(s)
Alloys , Chitosan , Coated Materials, Biocompatible , Magnesium , Titanium , Chitosan/chemistry , Titanium/chemistry , Alloys/chemistry , Corrosion , Magnesium/chemistry , Coated Materials, Biocompatible/chemistry , Zinc/chemistry , Materials Testing , Calcium/chemistry , Nanocomposites/chemistry
6.
J Trace Elem Med Biol ; 84: 127464, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38703537

ABSTRACT

INTRODUCTION: Titanium is considered to be an inert material owing to the ability of the material to form a passive titanium oxide layer. However, once the titanium oxide layer is lost, it can lead to exposure of the underlying titanium substructure and can undergo corrosion. SUMMARY: The article explores the role of titanium ions and particles from dental implants on cells, cytokine release, and on the systemic redistribution of these particles as well as theories proposed to elucidate the effects of these particles on peri-implant inflammation based on evidence from in-vitro, human, and animal studies. Titanium particles and ions have a pro-inflammatory and cytotoxic effect on cells and promote the release of pro-inflammatory mediators like cytokines. Three theories to explain etiopathogenesis have been proposed, one based on microbial dysbiosis, the second based on titanium particles and ions and the third based on a synergistic effect between microbiome and titanium particles on the host. CONCLUSION: There is clear evidence from in-vitro and limited human and animal studies that titanium particles released from dental implants have a detrimental effect on cells directly and through the release of pro-inflammatory cytokines. Future clinical and translational studies are required to clarify the role of titanium particles and ions in peri-implant inflammation and the etiopathogenesis of peri-implantitis.


Subject(s)
Cytokines , Dental Implants , Titanium , Humans , Dental Implants/adverse effects , Titanium/chemistry , Titanium/adverse effects , Cytokines/metabolism , Corrosion , Animals
7.
Int J Biol Macromol ; 269(Pt 2): 132065, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38714280

ABSTRACT

Natural gums due to availability, multifunctionality, and nontoxicity are multifaceted in application. In corrosion inhibition applications, their performance, in unmodified form is unsatisfactory because of high hydration rate, solubility issues, algal and microbial contamination, as well as thermal instability. This work attempts to enhance the inhibitive performance of Berlinia grandiflora (BEG) and cashew (CEG) exudate gums through various modification approaches. The potential of biogenic BEG and CEG gums-silver (Ag) nanocomposites (NCPs) for corrosion inhibition of mild steel in 1 M HCl is studied. The nanocomposites were characterized using the FTIR, UV-vis, and TEM techniques. The corrosion studies through the gravimetric and electrochemical (PDP, EIS, LPR, and EFM) analyses reveal moderate inhibition performance by the nanocomposites. Furthermore, the PDP results reveal that both inhibitors are mixed-type with maximum corrosion inhibition efficiencies (IEs) of 61.2 % and 54.2 % for BEG-Ag NCP and CEG-Ag NCP, respectively at an optimum concentration of 1.0 %. Modification of these inhibitors with iodide ion (KI) significantly increased the IE values to 90.1 % and 88.5 % for BEG-Ag NCP and CEG-Ag NCP at the same concentration. Surface observation of the uninhibited and inhibited steel samples using SEM/EDAX, 3D Surface profilometer, and AFM affirm that the modified nanocomposites are highly effective.


Subject(s)
Hydrochloric Acid , Nanocomposites , Plant Gums , Silver , Steel , Silver/chemistry , Steel/chemistry , Nanocomposites/chemistry , Corrosion , Hydrochloric Acid/chemistry , Plant Gums/chemistry , Plant Exudates/chemistry , Plant Exudates/pharmacology , Anacardium/chemistry
8.
Int J Biol Macromol ; 269(Pt 2): 132199, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38723824

ABSTRACT

This study explores the impacts of neem oil biodiesel (BD), which was produced and characterized using GC-MS, FTIR, and UV-Vis spectroscopic techniques to elucidate pure and corrosion-product neem oil BD at room temperature (25 °C) and different immersion durations of 0, 28, 42, and 56 days. The OM and SEM were also employed to study the surface, structural integrity, and interphase interaction between the BD and the carbon steel (C1020) before and after immersion for different durations. The dominant fatty acid (FA) group in both pure and corrosion-product neem oil BD was C18, with a total composition of 72.3 %, hence determining the nature of the BD interaction with the carbon steel. The study revealed that carbon steel (C1020) was susceptible to attacks by neem oil BD, and the duration of immersion had substantial influence on the surface morphology and structural integrity of the steel. It is therefore anticipated that this study will significantly advance the field of alternative fuel research.


Subject(s)
Alloys , Biofuels , Carbon , Glycerides , Steel , Steel/chemistry , Alloys/chemistry , Carbon/chemistry , Glycerides/chemistry , Surface Properties , Spectroscopy, Fourier Transform Infrared , Corrosion , Fatty Acids/chemistry , Terpenes
9.
Luminescence ; 39(5): e4753, 2024 May.
Article in English | MEDLINE | ID: mdl-38698700

ABSTRACT

A simple and environmentally friendly method was developed for smart and efficient waterborne polyurethane (PUR) paint. Sugarcane bagasse was recycled into reduced graphene oxide nanosheets (rGONSs). Both lanthanide-doped aluminate nanoparticles (LAN; photoluminescent agent, 7-9 nm) and rGONSs (reinforcement agent) were integrated into a waterborne polyurethane to produce a novel photoluminescent, hydrophobic, and anticorrosive nanocomposite coating. Using ferrocene-based oxidation under masked circumstances, graphene oxide nanosheets were produced from sugarcane bagasse. The oxidized semicarbazide (SCB) nanostructures were integrated into polyurethane coatings as a drying, anticorrosion, and crosslinking agent. Polyurethane coatings with varying amounts of phosphor pigment were prepared and subsequently applied to mild steel. The produced paints (LAN/rGONSs@PUR) were tested for their hydrophobicity, hardness, and scratch resistance. Commission Internationale de l'éclairage (CIE) Laboratory parameters and photoluminescence analysis established the opacity and colourimetric properties of the nanocomposite coatings. When excited at 365 nm, the luminescent transparent paints emitted a strong greenish light at 517 nm. The anticorrosion characteristics of the coated steel were investigated. The phosphor-containing (11% w/w) polyurethane coatings displayed the most pronounced anticorrosion capability and long-persistent luminosity. The prepared waterborne polyurethane paints were very photostable and durable.


Subject(s)
Graphite , Hydrophobic and Hydrophilic Interactions , Nanocomposites , Paint , Polyurethanes , Polyurethanes/chemistry , Graphite/chemistry , Nanocomposites/chemistry , Luminescence , Corrosion , Green Chemistry Technology
10.
Anal Chim Acta ; 1309: 342665, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772653

ABSTRACT

BACKGROUND: The concentration of cytochrome C is demonstrated to be an effective indicator of the microbial corrosion strength of metals. Traditional cytochrome C sensor can detect cytochrome C with a low detection limit, but their use is limited by their high cost, cumbersome operation, and susceptibility to malignant environments. In addition, studies on the monitoring of cytochrome C in the field of microbial corrosion has still not been carried out. Therefore, there is a need for a highly sensitive, selective, low-cost, anti-interference, and stable cytochrome C sensor with online monitoring and remote sensing capabilities for in-situ measurement of microbial corrosion strength. RESULTS: This paper proposed a highly sensitive label-free fiber-optic sensor based on Mach-Zehnder interferometer (MZI) for in-situ measurement of the microbial corrosion marker cytochrome C. Two-dimensional Ti2C-MXene material is uniformly immobilized onto the surface of the sensing area to improve the sensitivity, hydrophilicity, and specific surface area of the sensing area, as well as to facilitate the immobilization of specific sensitive materials. The cytochrome C antibody is modified on the surface of Ti2C-MXene to specifically recognize cytochrome C, whose concentration variation can be measured by monitoring the spectral shift of MZI sensor. Results demonstrate a measurement sensitivity of 1.428 nm/µM for cytochrome C concentrations ranging from 0 to 7.04 µM. The detection limit of the sensor is calculated to be 0.392 µM with remarkable performance, including selectivity, stability, and reliability. Besides, the measurement result of the proposed sensor in real microbial corrosive environment is consistent with that of the ideal environment. SIGNIFICANCE AND NOVELTY: This is the first instance of achieving in-situ and label-free measurement of cytochrome C by using a fiber-optic MZI sensor, which undoubtedly provides a feasible solution for the effective monitoring of microbial metal corrosion in the environment.


Subject(s)
Cytochromes c , Fiber Optic Technology , Interferometry , Titanium , Cytochromes c/analysis , Cytochromes c/metabolism , Titanium/chemistry , Biosensing Techniques/methods , Limit of Detection , Optical Fibers , Corrosion
11.
Acta Biomater ; 180: 171-182, 2024 May.
Article in English | MEDLINE | ID: mdl-38570108

ABSTRACT

Metallic bioresorbable orthopaedic implants based on magnesium, iron and zinc-based alloys that provide rigid internal fixation without foreign-body complications associated with permanent implants have great potential as next-generation orthopaedic devices. Magnesium (Mg) based alloys exhibit excellent biocompatibility. However, the mechanical performance of such implants for orthopaedic applications is contingent on limiting the rate of corrosion in vivo throughout the bone healing process. Additionally, the surgical procedure for the implantation of internal bone fixation devices may impart plastic deformation to the device, potentially altering the corrosion rate of the device. The primary objective of this study was to develop a computer-based model for predicting the in vivo corrosion behaviour of implants manufactured from a Mg-1Zn-0.25Ca ternary alloy (ZX10). The proposed corrosion model was calibrated with an extensive range of mechanical and in vitro corrosion testing. Finally, the model was validated by comparing the in vivo corrosion performance of the implants during preliminary animal testing with the corrosion performance predicted by the model. The proposed model accurately predicts the in vitro corrosion rate, while overestimating the in vivo corrosion rate of ZX10 implants. Overall, the model provides a "first-line of design" for the development of new bioresorbable Mg-based orthopaedic devices. STATEMENT OF SIGNIFICANCE: Biodegradable metallic orthopaedic implant devices have emerged as a potential alternative to permanent implants, although successful adoption is contingent on achieving an acceptable degradation profile. A reliable computational method for accurately estimating the rate of biodegradation in vivo would greatly accelerate the development of resorbable orthopaedic implants by highlighting the potential risk of premature implant failure at an early stage of the device development. Phenomenological corrosion modelling approach is a promising computational tool for predicting the biodegradation of implants. However, the validity of the models for predicting the in vivo biodegradation of Mg alloys is yet to be determined. Present study investigates the validity of the phenomenological modelling approach for simulating the biodegradation of resorbable metallic orthopaedic implants by using a porcine model that targets craniofacial applications.


Subject(s)
Absorbable Implants , Magnesium , Corrosion , Magnesium/chemistry , Animals , Calibration , Alloys/chemistry , Materials Testing
12.
Acta Biomater ; 180: 183-196, 2024 May.
Article in English | MEDLINE | ID: mdl-38604465

ABSTRACT

The utilization of biodegradable magnesium (Mg) alloys in the fabrication of temporary non-vascular stents is an innovative trend in biomedical engineering. However, the heterogeneous degradation profiles of these biomaterials, together with potential bacterial colonization that could precipitate infectious or stenotic complications, are critical obstacles precluding their widespread clinical application. In pursuit of overcoming these limitations, this study applies the principles of biomimicry, particularly the hydrophobic and anti-fouling characteristics of lotus leaves, to pioneer the creation of nanocomposite coatings. These coatings integrate poly-trimethylene carbonate (PTMC) with covalent organic frameworks (COFs), to modify the stent's surface property. The strategic design of the coating's topography, porosity, and self-polishing capabilities collectively aims to decelerate degradation processes and minimize biological adhesion. The protective qualities of the coatings were substantiated through rigorous testing in both in vitro dynamic bile tests and in vivo New Zealand rabbit choledochal models. Empirical findings from these trials confirmed that the implementation of COF-based nanocomposite coatings robustly fortifies Mg implantations, conferring heightened resistance to both biocorrosion and biofouling as well as improved biocompatibility within bodily environments. The outcomes of this research elucidate a comprehensive framework for the multifaceted strategies against stent corrosion and fouling, thereby charting a visionary pathway toward the systematic conception of a new class of reliable COF-derived surface modifications poised to amplify the efficacy of Mg-based stents. STATEMENT OF SIGNIFICANCE: Biodegradable magnesium (Mg) alloys are widely utilized in temporary stents, though their rapid degradation and susceptibility to bacterial infection pose significant challenges. Our research has developed a nanocomposite coating inspired by the lotus, integrating poly-trimethylene carbonate with covalent organic frameworks (COF). The coating achieved self-polishing property and optimal surface energy on the Mg substrate, which decelerates stent degradation and reduces biofilm formation. Comprehensive evaluations utilizing dynamic bile simulations and implantation in New Zealand rabbit choledochal models reveal that the coating improves the durability and longevity of the stent. The implications of these findings suggest the potential COF-based Mg alloy stent surface treatments and a leap forward in advancing stent performance and endurance in clinical applications.


Subject(s)
Absorbable Implants , Coated Materials, Biocompatible , Magnesium , Nanocomposites , Stents , Animals , Rabbits , Magnesium/chemistry , Magnesium/pharmacology , Nanocomposites/chemistry , Corrosion , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Metal-Organic Frameworks/chemistry , Metal-Organic Frameworks/pharmacology , Biofouling/prevention & control , Dioxanes/chemistry , Biomimetic Materials/chemistry , Biomimetic Materials/pharmacology , Polymers/chemistry , Polymers/pharmacology , Alloys/chemistry , Alloys/pharmacology
13.
Bioelectrochemistry ; 158: 108703, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38599139

ABSTRACT

The fluctuating water-line corrosion of EH40 steel in sterile and biotic media was investigated with a wire beam electrode. When the coupons were partially immersed in the sterile medium, the position of the low water-line acted as the cathodic zone and the area below the low water-line constantly served as the main anodic zone. The thin electrolyte layers with uneven thickness promoted the galvanic current of the region below the low water-line. Different from the sterile environment, the metabolism of Halomonas titanica with oxygen as the final electron acceptor reduced the dissolved oxygen concentration, which resulted in the position of the low water-line acting as the anodic zone.


Subject(s)
Halomonas , Steel , Halomonas/metabolism , Halomonas/chemistry , Corrosion , Steel/chemistry , Water/chemistry , Electrodes , Oxygen/chemistry , Oxygen/metabolism
14.
ACS Appl Bio Mater ; 7(5): 2966-2981, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38652577

ABSTRACT

This study presents a facile fabrication of 58S bioactive glass (BG)-polymer composite coatings on a 316L stainless steel (SS) substrate using the electrophoretic deposition technique. The suspension characteristics and deposition kinetics of BG, along with three different polymers, namely ethylcellulose (EC), poly(acrylic acid) (PAA), and polyvinylpyrrolidone (PVP), have been utilized to fabricate the coatings. Among all coatings, 58S BG and EC polymers are selected as the final composite coating (EC6) owing to their homogeneity and good adhesion. EC6 coating exhibits a thickness of ∼18 µm and an average roughness of ∼2.5 µm. Herein, EC6 demonstrates better hydroxyapatite formation compared to PAA and PVP coatings in simulated body fluid-based mineralization studies for a period of 28 days. Corrosion studies of EC6 in phosphate-buffered saline further confirm the higher corrosion resistance properties after 14 days. In vitro cytocompatibility studies using human placental mesenchymal stem cells demonstrate an increase in cellular viability, attachment, and higher proliferation compared to the bare SS substrate. EC6 coatings promote osteogenic differentiation, which is confirmed via the upregulation of the OPN and OCN genes. Moreover, the EC6 sample exhibits improved antibacterial properties against Escherichia coli and Staphylococcus aureus compared to the uncoated ones. The findings of this work emphasize the potential of electrophoretically fabricated BG-EC composite coatings on SS substrates for orthopedic applications.


Subject(s)
Coated Materials, Biocompatible , Glass , Materials Testing , Polymers , Stainless Steel , Stainless Steel/chemistry , Humans , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Glass/chemistry , Polymers/chemistry , Polymers/pharmacology , Corrosion , Particle Size , Surface Properties , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Escherichia coli/drug effects , Staphylococcus aureus/drug effects , Electrophoresis , Cell Survival/drug effects , Mesenchymal Stem Cells/drug effects , Mesenchymal Stem Cells/cytology , Microbial Sensitivity Tests , Cell Proliferation/drug effects
15.
J Biomater Appl ; 38(10): 1100-1117, 2024 May.
Article in English | MEDLINE | ID: mdl-38580320

ABSTRACT

The surface topological features of bioimplants are among the key indicators for bone tissue replacement because they directly affect cell morphology, adhesion, proliferation, and differentiation. In this study, we investigated the physical, electrochemical, and biological responses of sandblasted titanium (SB-Ti) surfaces with pore geometries fabricated using a plasma electrolytic oxidation (PEO) process. The PEO treatment was conducted at an applied voltage of 280 V in a solution bath consisting of 0.15 mol L-1 calcium acetate monohydrate and 0.02 mol L-1 calcium glycerophosphate for 3 min. The surface chemistry, wettability, mechanical properties and corrosion behavior of PEO-treated sandblasted Ti implants using hydroxyapatite particles (PEO-SB-Ti) were improved with the distribution of calcium phosphorous porous oxide layers, and showed a homogeneous and hierarchically porous surface with clusters of nanopores in a bath containing calcium acetate monohydrate and calcium glycerophosphate. To demonstrate the efficacy of PEO-SB-Ti, we investigated whether the implant affects biological responses. The proposed PEO-SB-Ti were evaluated with the aim of obtaining a multifunctional bone replacement model that could efficiently induce osteogenic differentiation as well as antibacterial activities. These physical and biological responses suggest that the PEO-SB-Ti may have a great potential for use an artificial bone replacement compared to that of the controls.


Subject(s)
Durapatite , Oxidation-Reduction , Surface Properties , Titanium , Titanium/chemistry , Porosity , Durapatite/chemistry , Bone Screws , Animals , Wettability , Materials Testing , Osteogenesis/drug effects , Electrolysis , Plasma Gases/chemistry , Cell Differentiation/drug effects , Corrosion , Biocompatible Materials/chemistry , Osteoblasts/cytology , Mice
16.
Environ Sci Pollut Res Int ; 31(21): 30353-30369, 2024 May.
Article in English | MEDLINE | ID: mdl-38637485

ABSTRACT

Chitosan stands out as the only known polysaccharide of its kind, second only to cellulose. As the second-largest biopolymer globally, chitosan and its derivatives are extensively used in diverse areas such as metal anti-corrosion prevention, food production, and medical fields. Its benefits include environmental friendliness, non-toxicity, cost-effectiveness, and biodegradability. Notably, the use of chitosan and its derivatives has gained substantial attention and has been extensively researched in the fields of metal anti-corrosion prevention and antibacterial applications. By means of chemical modification or synergistic action, the inherent limitations of chitosan can be substantially improved, thereby enhancing its biological and physicochemical properties to meet a wider range of applications and more demanding application requirements. This article offers a comprehensive review of chitosan and its modified composite materials, focusing on the enhancement of their anticorrosion and antibacterial properties, as well as the mechanisms by which they serve as anticorrosion and antibacterial agents. Additionally, it summarizes the synthesis routes of various modification methods of chitosan and their applications in different fields, aiming to contribute to the interdisciplinary development and potential applications of chitosan in various areas.


Subject(s)
Chitosan , Chitosan/chemistry , Chitosan/pharmacology , Corrosion , Anti-Infective Agents/pharmacology , Anti-Infective Agents/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry
17.
Int J Biol Macromol ; 267(Pt 2): 131429, 2024 May.
Article in English | MEDLINE | ID: mdl-38583828

ABSTRACT

Herein, a novel chitosan Schiff base (CS-FGA) as a sustainable corrosion inhibitor has been successfully synthesized via a simple amidation reaction by using an imidazolium zwitterion and chitosan (CS). The corrosion inhibition property of CS-FGA for mild steel (MS) in a 1.0 M HCl solution was studied by various electrochemical tests and physical characterization methods. The findings indicate that the maximum inhibition efficiency of CS-FGA as a mixed-type inhibitor for MS in 1.0 M HCl solution with 400 mg L-1 reaches 97.6 %, much much higher than the CS and the recently reported chitosan-based inhibitors. Scanning electron microscopy (SEM), atomic force microscopy (AFM), and water contact angle (WCA) results reveal that the CS-FGA molecules firmly adsorb on the MS surface to form a protective layer. The adsorption of CS-FGA on the MS surface belongs to the Langmuir adsorption isotherm containing both the physisorption and chemisorption. According to the X-ray photoelectron spectroscopy (XPS) and UV-vis spectrum, FeN bonds presented on the MS surface further prove the chemisorption between CS-FGA and Fe to generate the stable protective layer. Additionally, theoretical calculations from quantum chemical calculation (DFT) and molecular simulations (MD) were performed to reveal the inhibition mechanism of CS-FGA.


Subject(s)
Chitosan , Hydrochloric Acid , Steel , Chitosan/chemistry , Steel/chemistry , Corrosion , Hydrochloric Acid/chemistry , Adsorption , Schiff Bases/chemistry , Solutions , Photoelectron Spectroscopy , Surface Properties
18.
ACS Biomater Sci Eng ; 10(5): 3438-3453, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38564666

ABSTRACT

Despite being a weaker metal, zinc has become an increasingly popular candidate for biodegradable implant applications due to its suitable corrosion rate and biocompatibility. Previous studies have experimented with various alloy elements to improve the overall mechanical performance of pure Zn without compromising the corrosion performance and biocompatibility; however, the thermal stability of biodegradable Zn alloys has not been widely studied. In this study, TiC nanoparticles were introduced for the first time to a Zn-Al-Cu system. After hot rolling, TiC nanoparticles were uniformly distributed in the Zn matrix and effectively enabled phase control during solidification. The Zn-Cu phase, which was elongated and sharp in the reference alloy, became globular in the nanocomposite. The strength of the alloy, after introducing TiC nanoparticles, increased by 31% from 259.7 to 340.3 MPa, while its ductility remained high at 49.2% elongation to failure. Fatigue performance also improved greatly by adding TiC nanoparticles, increasing the fatigue limit by 47.6% from 44.7 to 66 MPa. Furthermore, TiC nanoparticles displayed excellent phase control capability during body-temperature aging. Without TiC restriction, Zn-Cu phases evolved into dendritic morphologies, and the Al-rich eutectic grew thicker at grain boundaries. However, both Zn-Cu and Al-rich eutectic phases remained relatively unchanged in shape and size in the nanocomposite. A combination of exceptional tensile properties, improved fatigue performance, better long-term stability with a suitable corrosion rate, and excellent biocompatibility makes this new Zn-Al-Cu-TiC material a promising candidate for biodegradable stents and other biodegradable applications.


Subject(s)
Absorbable Implants , Copper , Stents , Zinc , Zinc/chemistry , Zinc/pharmacology , Copper/chemistry , Copper/pharmacology , Alloys/chemistry , Humans , Titanium/chemistry , Titanium/pharmacology , Aluminum/chemistry , Aluminum/pharmacology , Materials Testing , Corrosion , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Metal Nanoparticles/chemistry , Metal Nanoparticles/therapeutic use , Nanoparticles/chemistry , Nanocomposites/chemistry
19.
Colloids Surf B Biointerfaces ; 238: 113880, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38581836

ABSTRACT

In the field of orthopedics, it's crucial to effectively slow down the degradation rate of Mg alloys. This study aims to improve the degradation behavior of Mg-Zn-Ca alloys by electrodepositing fluorohydroxyapatite (FHA). We investigated the microstructure and bond strength of the deposition, as well as degradation and cellular reactions. After 15-30 days of degradation in Hanks solution, FHA deposited alloys showed enhanced stability and less pH change. The strong interfacial bond between FHA and the Mg-Zn-Ca substrate was verified through scratch tests (Critical loads: 10.73 ± 0.014 N in Mg-Zn-0.5Ca alloys). Cellular studies demonstrated that FHA-coated alloys exhibited good cytocompatibility and promoted the growth of MC3T3-E1 cells. Further tests showed FHA-coated alloys owed improved early bone mineralization and osteogenic properties, especially in Mg-Zn-0.5Ca. This research highlighted the potential of FHA-coated Mg-Zn-0.5Ca alloys in orthopedics applications.


Subject(s)
Alloys , Calcium , Magnesium , Zinc , Alloys/chemistry , Alloys/pharmacology , Corrosion , Animals , Zinc/chemistry , Zinc/pharmacology , Magnesium/chemistry , Mice , Calcium/chemistry , Calcium/metabolism , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Surface Properties , Materials Testing , Cell Proliferation/drug effects , Hydroxyapatites/chemistry , Cell Line , Durapatite/chemistry , Durapatite/pharmacology
20.
ACS Biomater Sci Eng ; 10(5): 2880-2893, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38630940

ABSTRACT

Cobalt-chromium-molybdenum (CoCrMo) alloys are common wear-exposed biomedical alloys and are manufactured in multiple ways, increasingly using additive manufacturing processes such as laser powder bed fusion (LPBF). Here, we investigate the effect of proteins and the manufacturing process (wrought vs LPBF) and building orientation (LPBF-XY and XZ) on the corrosion, metal release, tribocorrosion, and surface oxide composition by means of electrochemical, mechanical, microscopic, diffractive, and spectroscopic methods. The study was conducted at pH 7.3 in 5 g/L NaCl and 5 mM 2-(N-morpholino) ethanesulfonic acid (MES) buffer, which was found to be necessary to avoid metal phosphate and metal-protein aggregate precipitation. The effect of 10 g/L bovine serum albumin (BSA) and 2.5 g/L fibrinogen (Fbn) was studied. BSA and Fbn strongly enhanced the release of Co, Cr, and Mo and slightly enhanced the corrosion (still in the passive domain) for all CoCrMo alloys and most for LPBF-XZ, followed by LPBF-XY and the wrought CoCrMo. BSA and Fbn, most pronounced when combined, significantly decreased the coefficient of friction due to lubrication, the wear track width and severity of the wear mechanism, and the tribocorrosion for all alloys, with no clear effect of the manufacturing type. The wear track area was significantly more oxidized than the area outside of the wear track. In the reference solution without proteins, a strong Mo oxidation in the wear track surface oxide was indicative of a pH decrease and cell separation of the anodic and cathodic areas. This effect was absent in the presence of the proteins.


Subject(s)
Lasers , Serum Albumin, Bovine , Corrosion , Serum Albumin, Bovine/chemistry , Cattle , Animals , Powders , Fibrinogen/chemistry , Materials Testing , Cobalt/chemistry , Surface Properties , Chromium/chemistry , Vitallium/chemistry
SELECTION OF CITATIONS