Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.817
Filter
1.
Methods Cell Biol ; 187: 1-41, 2024.
Article in English | MEDLINE | ID: mdl-38705621

ABSTRACT

Correlative light and electron microscopy (CLEM) is an approach that combines the strength of multiple imaging techniques to obtain complementary information about a given specimen. The "toolbox" for CLEM is broad, making it sometimes difficult to choose an appropriate approach for a given biological question. In this chapter, we provide experimental details for three CLEM approaches that can help the interested reader in designing a personalized CLEM strategy for obtaining ultrastructural data by using transmission electron microscopy (TEM). First, we describe chemical fixation of cells grown on a solid support (broadest approach). Second, we apply high-pressure freezing/freeze substitution to describe cellular ultrastructure (cryo-immobilization approach). Third, we give a protocol for a ultrastructural labeling by immuno-electron microscopy (immuno-EM approach). In addition, we also describe how to overlay fluorescence and electron microscopy images, an approach that is applicable to each of the reported different CLEM strategies. Here we provide step-by step descriptions prior to discussing possible technical problems and variations of these three general schemes to suit different models or different biological questions. This chapter is written for electron microscopists that are new to CLEM and unsure how to begin. Therefore, our protocols are meant to provide basic information with further references that should help the reader get started with applying a tailored strategy for a specific CLEM experiment.


Subject(s)
Microscopy, Electron, Transmission , Humans , Microscopy, Electron, Transmission/methods , Animals , Cryoelectron Microscopy/methods , Microscopy, Electron/methods , Microscopy, Immunoelectron/methods , Microscopy, Fluorescence/methods , Freeze Substitution/methods
2.
Methods Cell Biol ; 187: 205-222, 2024.
Article in English | MEDLINE | ID: mdl-38705625

ABSTRACT

Correlated super-resolution fluorescence microscopy and cryo-electron microscopy enables imaging with both high labeling specificity and high resolution. Naturally, combining two sophisticated imaging techniques within one workflow also introduces new requirements on hardware, such as the need for a super-resolution fluorescence capable microscope that can be used to image cryogenic samples. In this chapter, we describe the design and use of the "cryoscope"; a microscope designed for single-molecule localization microscopy (SMLM) of cryoEM samples that fits right into established cryoEM workflows. We demonstrate the results that can be achieved with our microscope by imaging fluorescently labeled vimentin, an intermediate filament, within U2OS cells grown on EM grids, and we provide detailed 3d models that encompass the entire design of the microscope.


Subject(s)
Cryoelectron Microscopy , Microscopy, Fluorescence , Microscopy, Fluorescence/methods , Cryoelectron Microscopy/methods , Humans , Vimentin/metabolism , Imaging, Three-Dimensional/methods , Single Molecule Imaging/methods , Cell Line, Tumor
3.
Methods Cell Biol ; 187: 223-248, 2024.
Article in English | MEDLINE | ID: mdl-38705626

ABSTRACT

Super-resolution cryo-correlative light and electron microscopy (SRcryoCLEM) is emerging as a powerful method to enable targeted in situ structural studies of biological samples. By combining the high specificity and localization accuracy of single-molecule localization microscopy (cryoSMLM) with the high resolution of cryo-electron tomography (cryoET), this method enables accurately targeted data acquisition and the observation and identification of biomolecules within their natural cellular context. Despite its potential, the adaptation of SRcryoCLEM has been hindered by the need for specialized equipment and expertise. In this chapter, we outline a workflow for cryoSMLM and cryoET-based SRcryoCLEM, and we demonstrate that, given the right tools, it is possible to incorporate cryoSMLM into an established cryoET workflow. Using Vimentin as an exemplary target of interest, we demonstrate all stages of an SRcryoCLEM experiment: performing cryoSMLM, targeting cryoET acquisition based on single-molecule localization maps, and correlation of cryoSMLM and cryoET datasets using scNodes, a software package dedicated to SRcryoCLEM. By showing how SRcryoCLEM enables the imaging of specific intracellular components in situ, we hope to facilitate adoption of the technique within the field of cryoEM.


Subject(s)
Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Humans , Single Molecule Imaging/methods , Electron Microscope Tomography/methods , Software , Image Processing, Computer-Assisted/methods , Vimentin/metabolism , Animals
4.
Methods Cell Biol ; 187: 175-203, 2024.
Article in English | MEDLINE | ID: mdl-38705624

ABSTRACT

Correlative cryo-microscopy pipelines combining light and electron microscopy and tomography in cryogenic conditions (cryoCLEM) on the same sample are powerful methods for investigating the structure of specific cellular targets identified by a fluorescent tag within their unperturbed cellular environment. CryoCLEM approaches circumvent one of the inherent limitations of cryo EM, and specifically cryo electron tomography (cryoET), of identifying the imaged structures in the crowded 3D environment of cells. Whereas several cryoCLEM approaches are based on thinning the sample by cryo FIB milling, here we present detailed protocols of two alternative cryoCLEM approaches for in situ studies of adherent cells at the single-cell level without the need for such cryo-thinning. The first approach is a complete cryogenic pipeline in which both fluorescence and electronic imaging are performed on frozen-hydrated samples, the second is a hybrid cryoCLEM approach in which fluorescence imaging is performed at room temperature, followed by rapid freezing and subsequent cryoEM imaging. We provide a detailed description of the two methods we have employed for imaging fluorescently labeled cellular structures with thickness below 350-500nm, such as cell protrusions and organelles located in the peripheral areas of the cells.


Subject(s)
Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Humans , Electron Microscope Tomography/methods , Microscopy, Fluorescence/methods , Imaging, Three-Dimensional/methods , Single-Cell Analysis/methods , Animals
5.
Methods Cell Biol ; 187: 249-292, 2024.
Article in English | MEDLINE | ID: mdl-38705627

ABSTRACT

Cryogenic ultrastructural imaging techniques such as cryo-electron tomography have produced a revolution in how the structure of biological systems is investigated by enabling the determination of structures of protein complexes immersed in a complex biological matrix within vitrified cell and model organisms. However, so far, the portfolio of successes has been mostly limited to highly abundant complexes or to structures that are relatively unambiguous and easy to identify through electron microscopy. In order to realize the full potential of this revolution, researchers would have to be able to pinpoint lower abundance species and obtain functional annotations on the state of objects of interest which would then be correlated to ultrastructural information to build a complete picture of the structure-function relationships underpinning biological processes. Fluorescence imaging at cryogenic conditions has the potential to be able to meet these demands. However, wide-field images acquired at low numeric aperture (NA) using air immersion objective have a low resolving power and cannot provide accurate enough three-dimensional (3D) localization to enable the assignment of functional annotations to individual objects of interest or target sample debulking to ensure the preservation of the structures of interest. It is therefore necessary to develop super-resolved cryo-fluorescence workflows capable of fulfilling this role and enabling new biological discoveries. In this chapter, we present the current state of development of two super-resolution cryogenic fluorescence techniques, superSIL-STORM and astigmatism-based 3D STORM, show their application to a variety of biological systems and discuss their advantages and limitations. We further discuss the future applicability to cryo-CLEM workflows though examples of practical application to the study of membrane protein complexes both in mammalian cells and in Escherichia coli.


Subject(s)
Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Humans , Animals , Imaging, Three-Dimensional/methods , Electron Microscope Tomography/methods , Image Processing, Computer-Assisted/methods , Microscopy, Fluorescence/methods
6.
Nat Commun ; 15(1): 3992, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38734767

ABSTRACT

Visual proteomics attempts to build atlases of the molecular content of cells but the automated annotation of cryo electron tomograms remains challenging. Template matching (TM) and methods based on machine learning detect structural signatures of macromolecules. However, their applicability remains limited in terms of both the abundance and size of the molecular targets. Here we show that the performance of TM is greatly improved by using template-specific search parameter optimization and by including higher-resolution information. We establish a TM pipeline with systematically tuned parameters for the automated, objective and comprehensive identification of structures with confidence 10 to 100-fold above the noise level. We demonstrate high-fidelity and high-confidence localizations of nuclear pore complexes, vaults, ribosomes, proteasomes, fatty acid synthases, lipid membranes and microtubules, and individual subunits inside crowded eukaryotic cells. We provide software tools for the generic implementation of our method that is broadly applicable towards realizing visual proteomics.


Subject(s)
Cryoelectron Microscopy , Electron Microscope Tomography , Proteasome Endopeptidase Complex , Proteomics , Ribosomes , Software , Electron Microscope Tomography/methods , Cryoelectron Microscopy/methods , Ribosomes/ultrastructure , Ribosomes/metabolism , Proteasome Endopeptidase Complex/ultrastructure , Proteasome Endopeptidase Complex/metabolism , Proteasome Endopeptidase Complex/chemistry , Humans , Proteomics/methods , Nuclear Pore/ultrastructure , Nuclear Pore/metabolism , Microtubules/ultrastructure , Microtubules/metabolism , Fatty Acid Synthases/metabolism , Machine Learning , Imaging, Three-Dimensional/methods , Algorithms , Image Processing, Computer-Assisted/methods
7.
J Am Chem Soc ; 146(19): 12925-12932, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38691507

ABSTRACT

Technological breakthroughs in cryo-electron microscopy (cryo-EM) methods open new perspectives for highly detailed structural characterizations of extracellular vesicles (EVs) and synthetic liposome-protein assemblies. Structural characterizations of these vesicles in solution under a nearly native hydrated state are of great importance to decipher cell-to-cell communication and to improve EVs' application as markers in diagnosis and as drug carriers in disease therapy. However, difficulties in preparing holey carbon cryo-EM grids with low vesicle heterogeneities, at low concentration and with kinetic control of the chemical reactions or assembly processes, have limited cryo-EM use in the EV study. We report a straightforward membrane vesicle cryo-EM sample preparation method that assists in circumventing these limitations by using a free-standing DNA-affinity superlattice for covering holey carbon cryo-EM grids. Our approach uses DNA origami to self-assemble to a solution-stable and micrometer-sized ordered molecular template in which structure and functional properties can be rationally controlled. We engineered the template with cholesterol-binding sites to specifically trap membrane vesicles. The advantages of this DNA-cholesterol-affinity lattice (DCAL) include (1) local enrichment of artificial and biological vesicles at low concentration and (2) isolation of heterogeneous cell-derived membrane vesicles (exosomes) from a prepurified pellet of cell culture conditioned medium on the grid.


Subject(s)
Cryoelectron Microscopy , DNA , Cryoelectron Microscopy/methods , DNA/chemistry , Extracellular Vesicles/chemistry , Humans , Cholesterol/chemistry , Liposomes/chemistry
8.
Sci Rep ; 14(1): 11165, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38750092

ABSTRACT

Kinetic aspects of enzymatic reactions are described by equations based on the Michaelis-Menten theory for the initial stage. However, the kinetic parameters provide little information on the atomic mechanism of the reaction. In this study, we analyzed structures of glutamate dehydrogenase in the initial and steady stages of the reaction using cryoEM at near-atomic resolution. In the initial stage, four metastable conformations displayed different domain motions and cofactor/ligand association modes. The most striking finding was that the enzyme-cofactor-substrate complex, treated as a single state in the enzyme kinetic theory, comprised at least three different metastable conformations. In the steady stage, seven conformations, including derivatives from the four conformations in the initial stage, made the reaction pathway complicated. Based on the visualized conformations, we discussed stage-dependent pathways to illustrate the dynamics of the enzyme in action.


Subject(s)
Cryoelectron Microscopy , Glutamate Dehydrogenase , Protein Conformation , Glutamate Dehydrogenase/chemistry , Glutamate Dehydrogenase/metabolism , Cryoelectron Microscopy/methods , Ligands , Kinetics , Models, Molecular , Coenzymes/metabolism , Coenzymes/chemistry , Catalysis , Protein Binding
10.
J Vis Exp ; (207)2024 May 10.
Article in English | MEDLINE | ID: mdl-38801255

ABSTRACT

Efficient methods for the extraction of features of interest remain one of the biggest challenges for the interpretation of cryo-electron tomograms. Various automated approaches have been proposed, many of which work well for high-contrast datasets where the features of interest can be easily detected and are clearly separated from one another. Our inner ear stereocilia cryo-electron tomographic datasets are characterized by a dense array of hexagonally packed actin filaments that are frequently cross-connected. These features make automated segmentation very challenging, further aggravated by the high-noise environment of cryo-electron tomograms and the high complexity of the densely packed features. Using prior knowledge about the actin bundle organization, we have placed layers of a highly simplified ball-and-stick actin model to first obtain a global fit to the density map, followed by regional and local adjustments of the model. We show that volumetric model building not only allows us to deal with the high complexity, but also provides precise measurements and statistics about the actin bundle. Volumetric models also serve as anchoring points for local segmentation, such as in the case of the actin-actin cross connectors. Volumetric model building, particularly when further augmented by computer-based automated fitting approaches, can be a powerful alternative when conventional automated segmentation approaches are not successful.


Subject(s)
Actins , Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Actins/chemistry , Electron Microscope Tomography/methods , Animals , Ear, Inner/diagnostic imaging , Actin Cytoskeleton/chemistry , Actin Cytoskeleton/ultrastructure
11.
J Vis Exp ; (207)2024 May 10.
Article in English | MEDLINE | ID: mdl-38801254

ABSTRACT

Over the past decade, advancements in technology and methodology within the field of cryogenic electron microscopy (cryo-EM) single-particle analysis (SPA) have substantially improved our capacity for high-resolution structural examination of biological macromolecules. This advancement has ushered in a new era of molecular insights, replacing X-ray crystallography as the dominant method and providing answers to longstanding questions in biology. Since cryo-EM does not depend on crystallization, which is a significant limitation of X-ray crystallography, it captures particles of varying quality. Consequently, the selection of particles is crucial, as the quality of the selected particles directly influences the resolution of the reconstructed density map. An innovative iterative approach for particle selection, termed CryoSieve, significantly improves the quality of reconstructed density maps by effectively reducing the number of particles in the final stack. Experimental evidence shows that this method can eliminate the majority of particles in final stacks, resulting in a notable enhancement in the quality of density maps. This article outlines the detailed workflow of this approach and showcases its application on a real-world dataset.


Subject(s)
Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Image Processing, Computer-Assisted/methods
12.
Nat Commun ; 15(1): 4395, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38782894

ABSTRACT

The conformational dynamics of nucleosome arrays generate a diverse spectrum of microscopic states, posing challenges to their structural determination. Leveraging cryogenic electron tomography (cryo-ET), we determine the three-dimensional (3D) structures of individual mononucleosomes and arrays comprising di-, tri-, and tetranucleosomes. By slowing the rate of condensation through a reduction in ionic strength, we probe the intra-array structural transitions that precede inter-array interactions and liquid droplet formation. Under these conditions, the arrays exhibite irregular zig-zag conformations with loose packing. Increasing the ionic strength promoted intra-array compaction, yet we do not observe the previously reported regular 30-nanometer fibers. Interestingly, the presence of H1 do not induce array compaction; instead, one-third of the arrays display nucleosomes invaded by foreign DNA, suggesting an alternative role for H1 in chromatin network construction. We also find that the crucial parameter determining the structure adopted by chromatin arrays is the angle between the entry and exit of the DNA and the corresponding tangents to the nucleosomal disc. Our results provide insights into the initial stages of intra-array compaction, a critical precursor to condensation in the regulation of chromatin organization.


Subject(s)
DNA , Electron Microscope Tomography , Nucleosomes , Nucleosomes/metabolism , Nucleosomes/ultrastructure , Nucleosomes/chemistry , Electron Microscope Tomography/methods , DNA/chemistry , DNA/metabolism , Cryoelectron Microscopy/methods , Nucleic Acid Conformation , Chromatin/chemistry , Chromatin/ultrastructure , Chromatin/metabolism , Histones/metabolism , Histones/chemistry , Osmolar Concentration , Animals
13.
Sci Data ; 11(1): 458, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38710720

ABSTRACT

The advent of single-particle cryo-electron microscopy (cryo-EM) has brought forth a new era of structural biology, enabling the routine determination of large biological molecules and their complexes at atomic resolution. The high-resolution structures of biological macromolecules and their complexes significantly expedite biomedical research and drug discovery. However, automatically and accurately building atomic models from high-resolution cryo-EM density maps is still time-consuming and challenging when template-based models are unavailable. Artificial intelligence (AI) methods such as deep learning trained on limited amount of labeled cryo-EM density maps generate inaccurate atomic models. To address this issue, we created a dataset called Cryo2StructData consisting of 7,600 preprocessed cryo-EM density maps whose voxels are labelled according to their corresponding known atomic structures for training and testing AI methods to build atomic models from cryo-EM density maps. Cryo2StructData is larger than existing, publicly available datasets for training AI methods to build atomic protein structures from cryo-EM density maps. We trained and tested deep learning models on Cryo2StructData to validate its quality showing that it is ready for being used to train and test AI methods for building atomic models.


Subject(s)
Artificial Intelligence , Cryoelectron Microscopy , Proteins , Cryoelectron Microscopy/methods , Proteins/chemistry , Proteins/ultrastructure , Models, Molecular , Protein Conformation
14.
Curr Opin Struct Biol ; 86: 102825, 2024 06.
Article in English | MEDLINE | ID: mdl-38723560

ABSTRACT

Knowledge of the structure and dynamics of biomolecules is key to understanding the mechanisms underlying their biological functions. Single-particle cryo-electron microscopy (cryo-EM) is a powerful structural biology technique to characterize complex biomolecular systems. Here, we review recent advances of how Molecular Dynamics (MD) simulations are being used to increase and enhance the information extracted from cryo-EM experiments. We will particularly focus on the physics underlying these experiments, how MD facilitates structure refinement, in particular for heterogeneous and non-isotropic resolution, and how thermodynamic and kinetic information can be extracted from cryo-EM data.


Subject(s)
Cryoelectron Microscopy , Molecular Dynamics Simulation , Cryoelectron Microscopy/methods , Thermodynamics , Kinetics , Single Molecule Imaging/methods
15.
Methods Mol Biol ; 2799: 269-280, 2024.
Article in English | MEDLINE | ID: mdl-38727913

ABSTRACT

N-Methyl-D-aspartate (NMDA) receptors are glutamate-gated excitatory channels that play essential roles in brain functions. While high-resolution structures were solved for an allosterically inhibited form of functional NMDA receptor, other key functional states (particularly the active open-channel state) have not yet been resolved at atomic resolutions. To decrypt the molecular mechanism of the NMDA receptor activation, structural modeling and simulation are instrumental in providing detailed information about the dynamics and energetics of the receptor in various functional states. In this chapter, we describe coarse-grained modeling of the NMDA receptor using an elastic network model and related modeling/analysis tools (e.g., normal mode analysis, flexibility and hotspot analysis, cryo-EM flexible fitting, and transition pathway modeling) based on available structures. Additionally, we show how to build an atomistic model of the active-state receptor with targeted molecular dynamics (MD) simulation and explore its energetics and dynamics with conventional MD simulation. Taken together, these modeling and simulation can offer rich structural and dynamic information which will guide experimental studies of the activation of this key receptor.


Subject(s)
Molecular Dynamics Simulation , Receptors, N-Methyl-D-Aspartate , Receptors, N-Methyl-D-Aspartate/metabolism , Receptors, N-Methyl-D-Aspartate/chemistry , Protein Conformation , Humans , Cryoelectron Microscopy/methods , Models, Molecular
16.
Acta Crystallogr F Struct Biol Commun ; 80(Pt 5): 107-115, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38767964

ABSTRACT

Imaging scaffolds composed of designed protein cages fused to designed ankyrin repeat proteins (DARPins) have enabled the structure determination of small proteins by cryogenic electron microscopy (cryo-EM). One particularly well characterized scaffold type is a symmetric tetrahedral assembly composed of 24 subunits, 12 A and 12 B, which has three cargo-binding DARPins positioned on each vertex. Here, the X-ray crystal structure of a representative tetrahedral scaffold in the apo state is reported at 3.8 Šresolution. The X-ray crystal structure complements recent cryo-EM findings on a closely related scaffold, while also suggesting potential utility for crystallographic investigations. As observed in this crystal structure, one of the three DARPins, which serve as modular adaptors for binding diverse `cargo' proteins, present on each of the vertices is oriented towards a large solvent channel. The crystal lattice is unusually porous, suggesting that it may be possible to soak crystals of the scaffold with small (≤30 kDa) protein cargo ligands and subsequently determine cage-cargo structures via X-ray crystallography. The results suggest the possibility that cryo-EM scaffolds may be repurposed for structure determination by X-ray crystallography, thus extending the utility of electron-microscopy scaffold designs for alternative structural biology applications.


Subject(s)
Ankyrin Repeat , Models, Molecular , Crystallography, X-Ray/methods , Cryoelectron Microscopy/methods , Ligands , Protein Conformation , Protein Binding , Gene Expression
17.
Int J Mol Sci ; 25(10)2024 May 17.
Article in English | MEDLINE | ID: mdl-38791508

ABSTRACT

Cryogenic electron tomography (cryoET) is a powerful tool in structural biology, enabling detailed 3D imaging of biological specimens at a resolution of nanometers. Despite its potential, cryoET faces challenges such as the missing wedge problem, which limits reconstruction quality due to incomplete data collection angles. Recently, supervised deep learning methods leveraging convolutional neural networks (CNNs) have considerably addressed this issue; however, their pretraining requirements render them susceptible to inaccuracies and artifacts, particularly when representative training data is scarce. To overcome these limitations, we introduce a proof-of-concept unsupervised learning approach using coordinate networks (CNs) that optimizes network weights directly against input projections. This eliminates the need for pretraining, reducing reconstruction runtime by 3-20× compared to supervised methods. Our in silico results show improved shape completion and reduction of missing wedge artifacts, assessed through several voxel-based image quality metrics in real space and a novel directional Fourier Shell Correlation (FSC) metric. Our study illuminates benefits and considerations of both supervised and unsupervised approaches, guiding the development of improved reconstruction strategies.


Subject(s)
Image Processing, Computer-Assisted , Neural Networks, Computer , Unsupervised Machine Learning , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Electron Microscope Tomography/methods , Cryoelectron Microscopy/methods , Algorithms , Deep Learning
18.
PLoS One ; 19(4): e0298287, 2024.
Article in English | MEDLINE | ID: mdl-38593135

ABSTRACT

Cryo-electron micrograph images have various characteristics such as varying sizes, shapes, and distribution densities of individual particles, severe background noise, high levels of impurities, irregular shapes, blurred edges, and similar color to the background. How to demonstrate good adaptability in the field of image vision by picking up single particles from multiple types of cryo-electron micrographs is currently a challenge in the field of cryo-electron micrographs. This paper combines the characteristics of the MixUp hybrid enhancement algorithm, enhances the image feature information in the pre-processing stage, builds a feature perception network based on the channel self-attention mechanism in the forward network of the Swin Transformer model network, achieving adaptive adjustment of self-attention mechanism between different single particles, increasing the network's tolerance to noise, Incorporating PReLU activation function to enhance information exchange between pixel blocks of different single particles, and combining the Cross-Entropy function with the softmax function to construct a classification network based on Swin Transformer suitable for cryo-electron micrograph single particle detection model (Swin-cryoEM), achieving mixed detection of multiple types of single particles. Swin-cryoEM algorithm can better solve the problem of good adaptability in picking single particles of many types of cryo-electron micrographs, improve the accuracy and generalization ability of the single particle picking method, and provide high-quality data support for the three-dimensional reconstruction of a single particle. In this paper, ablation experiments and comparison experiments were designed to evaluate and compare Swin-cryoEM algorithms in detail and comprehensively on multiple datasets. The Average Precision is an important evaluation index of the evaluation model, and the optimal Average Precision reached 95.5% in the training stage Swin-cryoEM, and the single particle picking performance was also superior in the prediction stage. This model inherits the advantages of the Swin Transformer detection model and is superior to mainstream models such as Faster R-CNN and YOLOv5 in terms of the single particle detection capability of cryo-electron micrographs.


Subject(s)
Algorithms , Electrons , Cryoelectron Microscopy/methods , Image Processing, Computer-Assisted/methods
19.
Acta Crystallogr D Struct Biol ; 80(Pt 5): 336-349, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38606666

ABSTRACT

Cryo-electron tomography (cryo-ET) enables molecular-resolution 3D imaging of complex biological specimens such as viral particles, cellular sections and, in some cases, whole cells. This enables the structural characterization of molecules in their near-native environments, without the need for purification or separation, thereby preserving biological information such as conformational states and spatial relationships between different molecular species. Subtomogram averaging is an image-processing workflow that allows users to leverage cryo-ET data to identify and localize target molecules, determine high-resolution structures of repeating molecular species and classify different conformational states. Here, STOPGAP, an open-source package for subtomogram averaging that is designed to provide users with fine control over each of these steps, is described. In providing detailed descriptions of the image-processing algorithms that STOPGAP uses, this manuscript is also intended to serve as a technical resource to users as well as for further community-driven software development.


Subject(s)
Algorithms , Cryoelectron Microscopy , Electron Microscope Tomography , Software , Cryoelectron Microscopy/methods , Electron Microscope Tomography/methods , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods
20.
Proc Natl Acad Sci U S A ; 121(18): e2319727121, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38669181

ABSTRACT

The DNA sliding clamp PCNA is a multipurpose platform for DNA polymerases and many other proteins involved in DNA metabolism. The topologically closed PCNA ring needs to be cracked open and loaded onto DNA by a clamp loader, e.g., the well-studied pentameric ATPase complex RFC (RFC1-5). The CTF18-RFC complex is an alternative clamp loader found recently to bind the leading strand DNA polymerase ε and load PCNA onto leading strand DNA, but its structure and the loading mechanism have been unknown. By cryo-EM analysis of in vitro assembled human CTF18-RFC-DNA-PCNA complex, we have captured seven loading intermediates, revealing a detailed PCNA loading mechanism onto a 3'-ss/dsDNA junction by CTF18-RFC. Interestingly, the alternative loader has evolved a highly mobile CTF18 AAA+ module likely to lower the loading activity, perhaps to avoid competition with the RFC and to limit its role to leading strand clamp loading. To compensate for the lost stability due to the mobile AAA+ module, CTF18 has evolved a unique ß-hairpin motif that reaches across RFC2 to interact with RFC5, thereby stabilizing the pentameric complex. Further, we found that CTF18 also contains a separation pin to locally melt DNA from the 3'-end of the primer; this ensures its ability to load PCNA to any 3'-ss/dsDNA junction, facilitated by the binding energy of the E-plug to the major groove. Our study reveals unique structural features of the human CTF18-RFC and contributes to a broader understanding of PCNA loading by the alternative clamp loaders.


Subject(s)
ATPases Associated with Diverse Cellular Activities , Cryoelectron Microscopy , Nuclear Proteins , Proliferating Cell Nuclear Antigen , Replication Protein C , Humans , Cryoelectron Microscopy/methods , DNA/metabolism , DNA/chemistry , DNA Replication , Models, Molecular , Proliferating Cell Nuclear Antigen/metabolism , Proliferating Cell Nuclear Antigen/chemistry , Protein Binding , Replication Protein C/metabolism , Replication Protein C/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...