Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Int. j. odontostomatol. (Print) ; 12(4): 368-375, dic. 2018. graf
Article in English | LILACS | ID: biblio-975759

ABSTRACT

ABSTRACT: The aim of this study was to carry out a literature review on the accuracy of conventional and digital dental impression methods, as well as present the various three-dimensional intraoral scanning systems. A bibliographic search was carried out in PUBMED's main health database, in which works published between 2008 and 2018 were collected. Laboratory studies, case reports and systematic reviews were included, addressing topics that deal with conventional digital materials, impression and precision. Articles that did not evaluate impression materials, their behavior and techniques to obtain a good impression of oral structures were excluded. Through a review in the literature, obtained the following findings: the most critical stage in macking a dental prothesis is to take the dental impression. The conventional technique of impression consists of obtaining a negative copy of the intra-oral situation that will be poured into gypsum, obtaining a positive copy, on which the work will be carried out. Digital scanning systems were not superior to conventional moldings when comparing fidelity, accuracy and detail reproduction; in contrast, they were superior to conventional impression when considering clinical chair time, patient and operator preference, and patient comfort.


RESUMEN: El objetivo de este estudio consistió en realizar una revisión bibliográfica sobre la precisión de los métodos de moldeo dental convencionales y digitales, así como presentar los diversos sistemas de escaneo intraoral tridimensionales. Se realizó una búsqueda bibliográfica en la base de datos de salud principal de PUBMED en la cual se recopilaron trabajos publicados entre 2008 y 2018. Se incluyeron estudios de laboratorio, informes de casos y revisiones sistemáticas, abordando temas que tratan con materiales digitales convencionales, moldeo y precisión. Se excluyeron los artículos que no evaluaron los materiales de moldeo, su comportamiento y técnicas para obtener una buena impresión de las estructuras orales. A través de una revisión exhaustiva en la literatura, obtuvimos los siguientes hallazgos: el paso más crítico en la preparación de una pieza protésica es la impresión de la preparación. La técnica convencional de moldeo consiste en obtener una copia negativa de la situación intraoral que se verterá en el yeso, obteniendo una copia positiva, sobre la cual se realizará el trabajo. Resulta que los sistemas de escaneo digital no fueron superiores a las molduras convencionales al comparar la fidelidad, precisión y reproducción de detalles; en cambio, fueron superiores a las molduras convencionales al considerar el tiempo de trabajo clínico, la preferencia del paciente y del operador y la comodidad del paciente.


Subject(s)
Humans , Dental Impression Technique/classification , Dental Impression Technique/instrumentation , Dental Impression Materials/chemistry , Dental Prosthesis Design , Printing, Three-Dimensional
2.
J Investig Clin Dent ; 1(1): 37-46, 2010 Aug.
Article in English | MEDLINE | ID: mdl-25427185

ABSTRACT

AIM: The present study is an in vitro study to evaluate the linear dimensional accuracy of commercially available polyvinyl siloxanes of varying viscosities using different impression techniques. METHODS: Different impression techniques used were: (a) putty wash, with a two-step technique with polyethylene spacer, using a stock tray; (b) putty wash, with a one-step technique, using a stock tray; (c) single-mix technique, utilizing medium viscosity in a custom tray; and (d) multiple-mix technique, utilizing a heavy- and low-viscosity combination in a custom tray. For each technique, 10 impressions were made of a metallic maxillary dentulous master model. RESULTS: The result of this study dictates that a heavy- and low-viscosity combination, double-mix technique in a custom tray produced an accurate result in all dimensions, followed by the single-mix technique, utilizing medium viscosity in a custom tray, and the putty wash two-step technique with polyethylene spacer, using a stock tray. Group 2 putty wash, one-step, simultaneous technique produced the least accurate result in all dimensions. CONCLUSION: The putty wash two-step techniques were found to be as accurate as the multiple-mix technique, utilizing a heavy- and low-viscosity combination in a custom tray, and the single-mix technique, utilizing medium viscosity in a custom tray. Making custom trays is time consuming and costly.


Subject(s)
Dental Impression Materials/chemistry , Dental Impression Technique , Polyvinyls/chemistry , Siloxanes/chemistry , Dental Impression Technique/classification , Dental Impression Technique/instrumentation , Desiccation , Equipment Design , Humans , Materials Testing , Models, Dental , Polyethylene/chemistry , Silicones/chemistry , Surface Properties , Temperature , Time Factors , Viscosity
3.
Dent Clin North Am ; 48(2): vi-vii, 445-70, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15172610

ABSTRACT

The contemporary restorative dentist has a host of impression materials available for making impressions in fixed prosthodontics,implant dentistry, and operative dentistry. With proper material selection and manipulation, accurate impressions can be obtained for fabrication of tooth- and implant-supported restorations. This article outlines the ideal properties of impression materials and explains the importance of critical manipulative variables. Available impression materials are analyzed relative to these variables, and several "specialized" impression techniques are described. Special attention is paid to polyvinyl siloxane impression materials because they have become the most widely used impression material in restorative dentistry.


Subject(s)
Dental Impression Materials/chemistry , Dental Impression Technique , Chemical Phenomena , Chemistry, Physical , Dental Impression Technique/classification , Dental Impression Technique/instrumentation , Dental Prosthesis Design , Humans , Polyvinyls/chemistry , Siloxanes/chemistry
6.
Rev. Fac. Odontol. Bauru ; 10(1): 35-41, jan.-mar. 2002. ilus, tab, graf
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-321830

ABSTRACT

O objetivo deste estudo foi o de avaliar o comportamento de moldes obtidos de diferentes técnicas de moldagem (por reembasamento sem e com alívio de lâmina plástica, e impressäo única simultânea), utilizando siliconas por adiçäo (SA), Express-3M e por condensaçäo (SC), 3M. Foi utilizado, como padräo, um troquel metálico simulando um preparo para coroa métalica. A partir deste foram obtidos, após a realizaçäo das diferentes técnicas de moldagem, troquéis de gesso (Durone-Dentsply). Nestes, foram feitos enceramentos de coroas com abertura oclusal e, em seguida, fundidos em liga de Cu-Al. No grupocontrole as fundiçöes foram obtidas diretamente do troquel padräo. O desajuste foi medido em funçäo dasdiscrepâncias das fundiçöes no troquel padräo, por meio de um microscópio de profundidade. Os resultados obtidos em m foram: Controle (fundiçäo obtida sem processo de moldagem)- 327,6; SC reembasamento sem alívio- 1734,1; SC reembasamento com alívio- 883,8; SC impressäo única- 598,6; SA reembasamento sem alívio- 571,6; SA reembasamento com alívio- 620,7; SA impressäo única- 648,6. Estas médias foram submetidas aos testes ANOVA e Tukey (p < 0,05). A técnica de impressäo única ou simultânea com silicona de reaçäo por condensaçäo promoveu resultados similares às técnicas com silicona por adiçäo. O processo de fundiçäo exerceu uma influência significativa na adaptaçäo das restauraçöes, sendo que a silicona por adiçäo sofreu menor influência face ao tipo de técnica de moldagem


Subject(s)
Dental Impression Materials , Dental Impression Technique/classification , Dental Casting Technique
7.
Stomatologiia (Mosk) ; 81(5): 58-61, 2002.
Article in Russian | MEDLINE | ID: mdl-12532891

ABSTRACT

Some classifications of anatomical impressions and the relevant terms are discussed. Methods for impression making are described in brief and their main characteristics are presented, based on which these methods are classified into groups. A new classification of impressions is suggested.


Subject(s)
Dental Impression Technique/classification , Dental Restoration, Permanent/methods , Terminology as Topic , Denture, Complete , Humans
8.
Rev. Fac. Odontol. Bauru ; 9(3/4): 167-172, jul.-dez. 2001. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-321822

ABSTRACT

Através da avaliaçäo de mensuraçöes horizontais em modelos de gesso tipo IV (Vel-mix) posicionadosnum perfilômetro, foram comparadas três técnicas de moldagens em implantes odontológicos. Na primeirafoi utilizado polissulfeto (Permlastic), moldeira individual e pinos cônicos (Nobelpharma), na segundapolissulfeto, moldeira individual e pinos quadrados (Nobelpharma), finalmente na terceira utilizou-sepolissulfeto, moldeira individual e pinos quadrados unidos com resina acrílica. Baseado na metodologiaempregada concluiu-se que näo houve alteraçöes estatisticamente significantes entre as três técnicas. Entretanto, as medidas de todos os modelos de gesso obtidos se apresentavam diferentes das do modeloOriginal


Subject(s)
Dental Impression Technique/classification , Dental Implants , Dental Prosthesis
9.
Gen Dent ; 49(3): 260-3, 2001.
Article in English | MEDLINE | ID: mdl-12004722

ABSTRACT

A great preparation is only as good as the impression and die made of it. Attention to every detail is necessary for a successful clinical result. By observing the clinical results, each individual dentist's experience will show the observant operator which technique works best. By combining experience, attention to detail, and patience, it is possible to achieve great fitting, adjustment-free esthetic dentistry.


Subject(s)
Dental Impression Technique , Astringents , Dental Impression Materials/classification , Dental Impression Technique/classification , Dental Impression Technique/instrumentation , Dental Porcelain , Dental Prosthesis Design/instrumentation , Dental Veneers , Equipment Design , Gingiva/anatomy & histology , Humans , Models, Dental , Surface Properties , Tooth/anatomy & histology , Tooth Preparation
11.
Rev. Fac. Odontol. Bauru ; 8(1/2): 23-9, jan.-jun. 2000. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-298437

ABSTRACT

Avaliou-se o reembasamento de moldes obtidos pela técnica de moldagem com resina acrílica gelada comparativamente à uma técnica convencional de moldagem com casquete preenchido com mercaptana. Foi utilizado um dispositivo metálico contendo um troquel para casquetes e um para moldagem. Os troquéis foram metalizados pela eletrodeposiçäo de íons prata no molde. A alteraçäo dimensional dos moldes foi mensurada em microscópio de profundidade, pela discrepância de alinhamento horizontal entre a borda oclusal de um anel de aço que simula uma coroa total e se adapta perfeitamente ao troquel padräo, e a face oclusal de cada troquel reproduzido. As médias das alteraçöes dimensionais e respectivos desvios-padräo, em micrômetros foram: A-) 678,8 (ñ59,2) para Duralay sem reembasamento, 379,9 (ñ72,9) para Duralay com reembasamento e 18,8 (ñ6,2) para o Permlastic. A resina acrílica sem reembasamento apresentou maior alteraçäo dimensional. Troquéis reproduzidos a partir dos moldes de mercaptana apresentaram-se dimensionalmente mais próximos do padräo. O reembasamento demonstrou proporcionar melhora significante na moldagem com a resina acrílica gelada


Subject(s)
In Vitro Techniques , Dental Impression Materials/chemistry , Dental Impression Technique/standards , Elastomers/classification , Elastomers/chemistry , Dental Materials/classification , Dental Materials/chemistry , Dental Impression Materials/classification , Models, Dental/classification , Models, Dental/standards , Acrylic Resins/classification , Acrylic Resins/chemistry , Dental Impression Technique/classification
16.
In. Galan Júnior, Joäo. Materiais dentários: o essencial para o estudante e o clínico geral. Säo Paulo, Santos, 1.ed; 1999. p.91-107, ilus.
Monography in Portuguese | LILACS, BBO - Dentistry | ID: lil-250780
18.
In. Ferreira, Flávio Vellini. Ortodontia: diagnóstico e planejamento clínico. Säo Paulo, Artes Médicas, 3 ed; 1999. p.141-57, ilus. (BR).
Monography in Portuguese | LILACS, BBO - Dentistry | ID: lil-271651
19.
In. Ferreira, Flávio Vellini. Ortodontia: diagnóstico e planejamento clínico. Säo Paulo, Artes Médicas, 3 ed; 1999. p.225-32, ilus, tab. (BR).
Monography in Portuguese | LILACS, BBO - Dentistry | ID: lil-271655
20.
Bauru; s.n; 1999. 162 p. ilus.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: lil-255897

ABSTRACT

As restauraçöes fixas säo rotineiramente fabricadas sobre um modelo de gesso, obtidos a partir do molde de um dente preparado. A precisäo na adaptaçäo destas é influenciada diretamente pelas propriedades dos materiais de moldagem empregado. Qualquer que seja o elastômero eleito, o método mais confiável para se avaliar o seu desempenho em conduzir a modelos de gesso fiéis, parece ser aquele no qual é empregado uma coroa-padräo que se adapta com precisäo a um troquel apropriado. Este trabalho tem por objetivo avaliar se dentre as técnicas da dupla moldagem (com alívio de 1 e 2 mm) e a do casquete, existe uma mais adequada ou se ambas apresentam adequaçöes suficiente e semelhantes. Foram empregados cinco elastômeros (Express, Impregum F, Imprint, Permlastic e President), os moldes foram obtidos empregando-se um dispositivo de moldagem idealizado por ARAÚJO e JORGENSEN (6) e vazados com gesso especial tipo IV (Vel-Mix). A coroa-padräo foi posicionada nos troquéis e avaliada, quanto à sua precisäo de adaptaçäo, em um microscópio de mediçäo de profundidade. Os resultados mostraram que a técnica do casquete apresentou melhores resultados para os materiais Impregum F e Imprint, vindos a seguir o Express e o President (ambos com alívio de 2 mm) e o Express (alívio de 1 mm); o Permlastic e o Express, na técnica do casquete, apresentaram piores resultados que os anteriores, mas semelhnates entre si, sendo o President (casquete) semelhante à este último; o President (alívio de 1 mm), foi o que apresentou pior resultado


Subject(s)
Dental Impression Technique/classification , Dental Impression Technique/instrumentation , Crowns , Silicone Elastomers/chemistry , Dental Impression Materials/chemistry , Models, Anatomic
SELECTION OF CITATIONS
SEARCH DETAIL
...