Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.422
Filter
1.
Clin Oral Investig ; 28(6): 340, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801642

ABSTRACT

BACKGROUND: Pediatric rotary file systems were developed to solve manual file limitations. With many systems available, it may be tricky to select the most appropriate one. AIM: to assess & compare Kedo-S Square, Fanta-AF™-Baby rotary files with manual K-file concerning removed dentin amount, canal transportation, centric ability & root canal taper using CBCT in primary anterior teeth. DESIGN: Extracted Seventy-five upper primary anterior teeth with intact 2/3 root length were collected and divided into three groups based on root canal instrumentation, group-I: prepared using K-file, group-II: prepared using Kedo-S Square, and group-III: prepared using Fanta AF™ Baby file. The teeth were imaged with CBCT before & following canal instrumentation. Then, the removed dentin amount was calculated at each root-canal level. The Kruskal-Wallis test was utilized to statistically analyze study data. RESULT: The difference among the three groups was highly statistically significant at cervical & apical thirds concerning dentin thickness changes on both mesial & distal sides following canal preparation with the least removed dentin in the Kedo-S Square group(P < 0.0001). Regarding transportation & centering ability, a non-significant difference between the three groups was found. 80% of the Fanta AF™ Baby group had good-tapered preparation compared to the Kedo-S Square (72%) and K-file (40%) groups(P < 0.05). CONCLUSION: Kedo-S Square was preferable to Fanta-AFTM-Baby & manual K-files in primary root canal preparation.


Subject(s)
Cone-Beam Computed Tomography , Equipment Design , Root Canal Preparation , Tooth, Deciduous , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Cone-Beam Computed Tomography/methods , In Vitro Techniques , Tooth, Deciduous/diagnostic imaging , Incisor/diagnostic imaging , Dental Instruments , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Dental Pulp Cavity/surgery
2.
BMC Oral Health ; 24(1): 585, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773530

ABSTRACT

Periodontal instrument fractures are rare events in dentistry, with limited literature available on their occurrence and management. This case report highlights an incident involving the fracture of a periodontal sickle scaler blade during manual instrumentation for the removal of calculus. The fracture occurred during instrumentation on the mesial surface of the maxillary right second molar, and the separated blade was subsequently pushed into the sulcus. A radiographic assessment was performed to verify the precise location of the fractured segment. Following confirmation, the broken blade was subsequently retrieved using curved artery forceps. The case report highlights factors contributing to instrument fractures, emphasizing the importance of instrument maintenance, sterilization cycles, and operator technique. Ethical considerations regarding patient disclosure, informed consent, and instrument retrieval methods are well discussed. This case underscores the importance of truthful communication, the proper use of instruments, equipment maintenance in dentistry, and the significance of ongoing professional development to enhance treatment safety, proficiency, and ethical standards in dental care.


Subject(s)
Equipment Failure , Humans , Male , Dental Instruments/adverse effects , Dental Scaling , Ethics, Dental , Middle Aged
3.
Clin Exp Dent Res ; 10(3): e893, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770579

ABSTRACT

OBJECTIVES: The present study reviews the current literature regarding the utilization of the extended finite element method (XFEM) in clinical and experimental endodontic studies and the suitability of XFEM in the assessment of cyclic fatigue in rotary endodontic nickel-titanium (NiTi) instruments. MATERIAL AND METHODS: An electronic literature search was conducted using the appropriate search terms, and the titles and abstracts were screened for relevance. The search yielded 13 hits after duplicates were removed, and four studies met the inclusion criteria for review. RESULTS: No studies to date have utilized XFEM to study cyclic fatigue or crack propagation in rotary endodontic NiTi instruments. Challenges such as modelling material inputs and fatigue criteria could explain the lack of utilization of XFEM in the analysis of mechanical behavior in NiTi instruments. CONCLUSIONS: The review showed that XFEM was seldom employed in endodontic literature. Recent work suggests potential promise in using XFEM for modelling NiTi structures.


Subject(s)
Endodontics , Finite Element Analysis , Nickel , Titanium , Humans , Dental Alloys/chemistry , Dental Instruments , Endodontics/instrumentation , Endodontics/methods , Materials Testing , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Stress, Mechanical
4.
J Contemp Dent Pract ; 25(3): 250-259, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690699

ABSTRACT

AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Filling Materials , Root Canal Obturation , Root Canal Preparation , Tomography, Spiral Computed , Tooth, Deciduous , Humans , Root Canal Obturation/methods , Tooth, Deciduous/diagnostic imaging , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Tomography, Spiral Computed/methods , Molar/diagnostic imaging , Dental Instruments , In Vitro Techniques
5.
Dent Med Probl ; 61(2): 269-278, 2024.
Article in English | MEDLINE | ID: mdl-38686969

ABSTRACT

Nickel-titanium (NiTi) file separation during endodontic treatment is an undesirable event. This phenomenon needs to be understood by knowing the factors influencing fracture in endodontic files. There is a large amount of literature where these factors and their influence have been studied, increasing the knowledge about the mechanisms involved, mainly related to wire technology, file shapes and geometry, operator manipulation, the anatomy of the root canal, and the irrigation and sterilization processes. As many factors are involved, the complexity of the fracture phenomena increases and the isolated correlation of one factor with the file fracture becomes a small part of comprehending the separation phenomena. This thematic review aims to compile important reports from 2014 to 2022 on the factors influencing NiTi file separation. The information obtained was classified into wire technology, file geometry, operational aspects, irrigation and sterilization, and anatomy. For this purpose, the Scopus, Web of Science and ScienceDirect databases were consulted using a search string. Filters were applied to consolidate the final set of relevant papers covering the subject of factors influencing endodontic file separation. It was found that the fracture of NiTi files incorporates different mechanisms that operate simultaneously during the endodontic procedure and strongly affect the instrument performance. The collected information promotes good practices to prevent file separation.


Subject(s)
Nickel , Root Canal Preparation , Titanium , Humans , Root Canal Preparation/instrumentation , Equipment Failure , Equipment Design , Sterilization , Dental Instruments
7.
Shanghai Kou Qiang Yi Xue ; 33(1): 54-58, 2024 Feb.
Article in Chinese | MEDLINE | ID: mdl-38583025

ABSTRACT

PURPOSE: To compare the forming ability of four kinds of nickel-titanium instrument preparation resin for simulated curved root canal. METHODS: A total of 40 single bend resin simulated root canals were randomly divided into 4 groups with 10 in each group. Four kinds of nickel-titanium instruments (ProTaper, HyFlex EDM, WaveOne Gold and Reciproc Blue) were used for root canal preparation, and divided into group A, group B, group C and group D. The preparation time of the four groups was compared, the root canal images before and after preparation were analyzed by computer image analysis software, and the changes of the preparation time, curvature and curvature radius of the four groups were recorded. With the root tip as the center of the circle, the radius of 1-10 mm was selected as concentric circle arcs. The detection points were overlapping root canal intersection points. The resin removal amount and center positioning force of the inner and outer walls of the root canal at different detection points were recorded. Statistical analysis was performed with SPSS 20.0 software package. RESULTS: The root canal preparation time in group A was significant longer than that in group B, C and D(P<0.05), but there was no significant difference in the curvature and curvature radius of the root canal among the four groups (P>0.05). The removal amount of resin from the root canal wall in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 8, 9 and 10 mm, respectively. The removal amount of resin from the outer wall of the root canal in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 7, 9 and 10 mm, respectively. The root tip offset of group A from the detection point to the apical hole of 1, 2, 3, 4, 6, 7, 8, 9 and 10 mm was significant greater than that of group B, C and D(P<0.05). CONCLUSIONS: Among the four instruments, ProTaper has the largest apical deviation, HyFlex EDM, WaveOne Gold and Reciproc Blue have better ability of root canal forming.


Subject(s)
Dental Pulp Cavity , Titanium , Nickel , Dental Instruments , Root Canal Preparation/methods , Equipment Design
8.
BMC Oral Health ; 24(1): 416, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580975

ABSTRACT

OBJECTIVE: To investigate the status and related factors of sterilizers in dental health-care settings in Yunnan Province, with the aim of providing a theoretical basis for the health administrative department to formulate regional quality control programs and systems, proposing reasonable suggestions for optimizing the allocation of sterilizer resources in Yunnan's dental health-care settings, thereby improving resource utilization efficiency. METHODS: This cross-sectional survey was conducted in 2600 dental health-care settings in Yunnan Province in March 2020. Uni-variable linear regression, multi-variable linear regression, curve fitting and threshold effect analysis were used to understand the relationship between dental units and sterilizers. RESULTS: A total of 2600 dental health-care settings were included. The disinfection and sterilization work were mainly completed by the dental department in 1510(58.1%) institutions. 44(1.7%) institutions were not allocated sterilization equipment, and 1632 (62.8%) had only one sterilizer. The median allocation of sterilizers was 1.0. Uni-variable linear regression showed significant differences in covariates such as dental unit, dental handpiece, disinfection equipment, dentist, and dental assistant, which were more sensitive (p < 0.001) and statistically significant. The adjusted model was more stable in the multi-variable linear regression, and the differences in covariates between different settings were statistically significant. Curve fitting revealed an S-shaped curvilinear relationship between the number of dental units and sterilizers in oral healthcare settings. CONCLUSION: The disinfection and sterilization work was mainly completed by the dental department in dental health-care settings in Yunnan Province. Sterilizer allocation increases with the number of dental units, but some institutions have insufficient allocation of sterilizer and manpower resources, resulting in certain risks of infection control. Thus, it is necessary to strengthen supervision, inspection and regional quality control work in infection control of dentistry.


Subject(s)
Disinfection , Infection Control , Humans , Cross-Sectional Studies , China , Dental Instruments
9.
Dent Mater J ; 43(3): 329-337, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38583993

ABSTRACT

The aim of this study was to evaluate how preset torque settings influence the torque, vertical force, and root canal-centering ability of ProGlider and ProTaper NEXT nickel-titanium rotary instruments in canals with different curvature locations. Based on micro-computed tomography, mesial roots of human mandibular molars (25°-40° curvature) were allocated to the apical curvature (apical 1-5 mm) or the middle curvature (apical 5-9 mm) groups, and mandibular incisors (curvature <5°) to the straight canal group. Each group was subjected to automated instrumentation and torque/force measurement with the preset torque of 1, 2.5, or 5 N•cm. Canal-centering ratios were determined with micro-computed tomography. Instrument fracture occurred only in the 2.5 and 5 N•cm groups in curved canals. The preset torque setting and curvature location did not influence canal shaping ability.


Subject(s)
Nickel , Root Canal Preparation , Surface Properties , Titanium , Torque , X-Ray Microtomography , Humans , Titanium/chemistry , Nickel/chemistry , Root Canal Preparation/instrumentation , In Vitro Techniques , Dental Pulp Cavity , Molar , Dental Instruments , Materials Testing , Equipment Design , Dental Alloys/chemistry , Dental Stress Analysis
10.
Eur Arch Paediatr Dent ; 25(2): 181-189, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38461490

ABSTRACT

PURPOSE: Pulpectomy can be used for the management of deep dentinal carious lesions in primary teeth which can be restored. Mechanical preparation of root canals can be performed using hand or NiTi rotary files. However, this may cause dentinal stress and consequently dentinal microcracks. Hence, the aim was comparative evaluation of hand and rotary file systems on dentinal microcrack formation during pulpectomy procedure in primary teeth. METHODS: 60 extracted primary molar teeth were selected comprising of 80 root canals. Simple random sampling was used to divide root canals into four groups (n = 20): Group A-Hedstrom file, Group B-Pro AF Baby Gold rotary, Group C-ProTaper Next rotary, and Group D-unprepared group. Assessment was conducted on presence or absence of microcracks using Chi square test (p < 0.05). RESULTS: The total number of microcracks in Group A: one (5%), Group B: four (20%), Group C: nine (45%) and Group D: zero (0%) which was statistically significant (p = 0.002). At cervical third, the number of microcracks seen with Group A: one (5%), Group B: zero (0%), Group C: five (25%) and Group D: zero (0%) (p = 0.005). At the middle third, the number of microcracks seen in Group A: zero (0%), Group B: four (20%), Group C: four (20%) and Group D: zero (0%) (p = 0.029). CONCLUSION: The study concluded that dentinal microcracks are formed with both hand and rotary file systems in primary teeth. ProTaper Next showed significantly higher number of microcracks, followed by ProAF Baby Gold and H files.


Subject(s)
Dentin , Pulpectomy , Root Canal Preparation , Tooth, Deciduous , Humans , Tooth, Deciduous/surgery , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Pulpectomy/methods , Dentin/injuries , In Vitro Techniques , Dental Instruments/adverse effects , Molar/surgery , Equipment Design , Dental Pulp Cavity/surgery , Nickel
11.
Eur Arch Paediatr Dent ; 25(2): 227-235, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38472709

ABSTRACT

PURPOSE: To evaluate the volumetric changes of two recently introduced paediatric rotary file systems in comparison with conventional hand file systems in primary maxillary canines using an ultra-high-resolution nano-computed tomography. METHODS: This in vitro study was performed in extracted primary maxillary canines based on certain inclusion and exclusion criteria. Samples were prepared, and working length was determined after the pre-operative scan using a high-resolution nano-CT device (SkyScan 2214, Bruker, Kontich, Belgium). A single well-experienced paediatric dentist prepared the canals using three file systems: Kedo-S plus, Kedo-SG blue and hand K-files. All samples were subjected to post-operative scans performed similar to pre-operative scans. Image reconstruction was performed with NRecon software for 3D volumetric visualisation and analysis of the root canals. RESULTS: Kedo-SG blue file systems had the highest mean difference in the canal volume (4.05%). Hand K-files had the least difference at (3.71%) of canal volume. Kedo-S plus file system had a moderate mean canal volume difference (3.82%) which is closer to hand K-files. Intergroup comparison between the three groups showed that the mean difference in canal volume was statistically significant between all three file systems (p = 0.000). CONCLUSION: Within the limitations of the current study, rotary file systems produced a significant enlargement of canals as compared to hand files. Kedo-SG blue created a uniform preparation of the canal cervico-apically. Kedo-S plus files were prepared more coronally with minimal preparation apically as close to the preparation of hand files. TRIAL REGISTRATION: Trial registration number: IHEC/SDC/PEDO-2103/22/651, Date of registration: 2022.


Subject(s)
Cuspid , Dental Pulp Cavity , Maxilla , Root Canal Preparation , Tooth, Deciduous , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Cuspid/diagnostic imaging , Cuspid/anatomy & histology , Tooth, Deciduous/diagnostic imaging , Tooth, Deciduous/anatomy & histology , Maxilla/diagnostic imaging , In Vitro Techniques , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Dental Instruments , Equipment Design
12.
J Endod ; 50(4): 520-526, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38311116

ABSTRACT

INTRODUCTION: This study aimed to evaluate the effects from the memory-triple (MT) heat treatment on the fatigue resistance of the Reciproc by comparison with the file systems of same geometry. METHODS: Reciproc files subjected to MT heat treatment technology were designated as Group RMT and were compared with the original Reciproc (Group REC) and Reciproc Blue (Group REB). Each NiTi file from 3 groups (n = 15) was operated reciprocally with a repetitive up-and-down movement in the curved canal with 4 mm of pecking distance inside of the simulated canal at body temperature. When each file fractured, the time until fracture was recorded. The length of the fractured fragment was measured. Fractured fragments were observed under scanning electron microscope (SEM) to evaluate the topographic features of the surface. Differential scanning calorimetry (DSC) analysis was performed to estimate phase transformation temperatures. One-way analysis of variance and Duncan post hoc comparison were applied to compare among the groups at a significance level of 95%. RESULTS: RMT showed significantly higher fracture resistance (P < .05), whereas there was no difference in fatigue resistance between REC and REB. SEM examination showed the files from the 3 groups had similar topographic features. RMT showed a peak of austenite peak (Ap) at a temperature (52°C) higher than body temperature, whereas REC and REB showed Ap at 37 and 32°C, respectively. CONCLUSIONS: Under the condition of this study, the new heat treatment technique of MT technology could enhance the fatigue fracture resistance of the reciprocating files made of M-wire and Blue-wire.


Subject(s)
Hot Temperature , Root Canal Preparation , Equipment Failure , Stress, Mechanical , Dental Instruments , Materials Testing , Equipment Design , Titanium
13.
J Endod ; 50(5): 619-626, 2024 May.
Article in English | MEDLINE | ID: mdl-38311114

ABSTRACT

INTRODUCTION: Determination of the glide path is recommended before using rotary instruments. This study aimed to evaluate the dynamic cyclic fatigue resistance of new and used glider rotary instruments in up to 6 root canals. METHODS: Seventy-two TruNatomy Glider files were used for the preparation of root canals of extracted lower molars, which were then submitted to the dynamic cyclic fatigue test carried out in a curved metallic artificial canal. The instruments were divided into 4 groups (n = 18): Control group, new instruments without any use in the root canal; Group 2U, instruments used in 2 mesial canals; Group 4U, instruments used in 4 mesial canals; Group 6U, instruments used in 6 mesial canals. The time to failure (TF) of the instrument was recorded, and the number of cycles to failure (NCF) was calculated. The data were submitted to 1-way analysis of variance and to the Games-Howell test for multiple comparisons, adopting a significance level of 5%. RESULTS: TF and NCF were significantly affected by the number of file uses. The Games-Howell test revealed that TF and NCF were significantly greater in the control group than in Group 4U. In Group 2U, TF and NCF were intermediate and not significantly different from the control group. Group 6U had significantly lower TF and NCF than all other groups. CONCLUSION: The TruNatomy Glider can be used as a glide path for up to 2 mesial canals of mandibular molars, whereas its use on 4 or 6 root canals is not suggested.


Subject(s)
Equipment Failure , Root Canal Preparation , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Humans , Dental Instruments , Equipment Design , In Vitro Techniques , Molar , Dental Stress Analysis , Dental Pulp Cavity , Materials Testing
14.
São Paulo; s.n; 20240222. 152 p.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1531900

ABSTRACT

Introdução: Mucosite oral é um efeito colateral dos tratamentos oncológicos, caracterizado por lesões orais que vão de eritema a úlceras que podem causar dor intensa e restrição de dieta. É conhecida como condição limitante e de grande impacto na qualidade de vida (QV). Objetivo: Elaborar um novo instrumento para avaliar a QV relacionada à mucosite oral. Material e método: Pesquisa através de métodos mistos, iniciando com entrevistas qualitativas analisadas pelo método de Bardin e método Reinert, com o programa IRAMUTEQ, seguido do método Delphi com quatro rodas de entrevistas e discussões com especialistas. A primeira versão do instrumento passou por um pré-teste com 10 pacientes, com análise quantitativa e qualitativa, seguido de outra rodada de especialistas. Resultados: O material das entrevistas qualitativas apontou os termos dor e alimentação como centrais na experiência de mucosite oral, além de fornecerem várias palavras-chave para definição dos constructos. Baseado nesse material e na literatura, 4 especialistas formularam 34 perguntas enviadas para outros 10 especialistas de diferentes regiões e instituições brasileiras que analisaram a clareza, ortografia e necessidade de cada pergunta para o questionário. As alterações pertinentes foram realizadas, revisadas e novamente discutidas. A primeira versão foi apresentada a 10 pacientes que não participaram das entrevistas qualitativas e responderam o grau de entendimento e necessidade de cada pergunta. A análise final do pré-teste reformulou alguns tempos verbais e palavras de difícil compreensão, dando forma a versão final do instrumento. Discussão: Embora existam bons instrumentos para mensurar QV e mucosite oral, apresentamos novas questões sobre impactos financeiros, interrupção de tratamento, alteração de saliva, perda de peso relacionada diretamente com a mucosite oral e aspectos psicossociais. Conclusão: Foi elaborado um novo instrumento para mensurar os impactos mucosite oral em pacientes oncológicos.


Subject(s)
Quality of Life , Stomatitis , Surveys and Questionnaires , Dental Instruments
15.
Int Endod J ; 57(5): 601-616, 2024 May.
Article in English | MEDLINE | ID: mdl-38376108

ABSTRACT

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Subject(s)
Dental Instruments , Titanium , Cross-Sectional Studies , Equipment Design , Materials Testing , Stress, Mechanical , Titanium/chemistry , Root Canal Preparation , Metallurgy
16.
Eur Endod J ; 9(2): 133 - 138, 2024 03 08.
Article in English | MEDLINE | ID: mdl-38268112

ABSTRACT

OBJECTIVE: To evaluate the impact of different file access angles and root canal curvature's location on the fatigue failure of One Curve (OC) and E3 Azure (EZ) NiTi files using a dynamic model at simulated body temperature. METHODS: Eighty new instruments with similar tip sizes and taper (#25/0.06) from two NiTi rotary systems, One Curve and E3 Azure, were tested at simulated body temperatures (37°C) using a custom-made dynamic cyclic fatigue device. Instruments were divided into four subgroups according to the location of root canal curvature (a coronal curve 5 mm from the root canal orifice and an apical curve 10 mm from the root canal orifice) and the angle of file access (0° or 30°). Instruments were operated in simulated stainless-steel canals having a 60° curve and a 3 mm radius. A custom-made device produced controlled vertical pecks during file rotation. Time to failure (sec) was registered, and the length of the fragment segments was measured (mm). Data were analysed statistically with One-Way ANOVA and Tukey post hoc tests. The significance level was set at 5%. All separated instruments were examined by scanning electron microscope. RESULTS: One-way ANOVA (p<0.05) found a significant difference among the tested instruments. Post Hoc analysis revealed lower cyclic fatigue resistance when the angle of file access was 30º, and the root canal curvature was located coronally for both files (p<0.0001). Three-way ANOVA showed that the angle of file access was the most influential contributor to cyclic fatigue, followed by the location of file curvature and, finally, the file type (p<0.0001). The fractographic examination revealed a predominantly ductile fracture mode for all tested instruments. The lengths of all fractured segments showed no significant difference (p>0.05), indicating an accurate trajectory during testing. CONCLUSION: OC files had superior cyclic fatigue resistance than EZ files; coronal curvatures negatively impacted cyclic fatigue resistance compared to apical curvatures, while the angle of file access presented the highest impact on dynamic cyclic fatigue.


Subject(s)
Alloys , Dental Alloys , Dental Instruments , Nickel , Titanium , Equipment Failure , Root Canal Preparation
18.
J Endod ; 50(2): 213-219, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37924940

ABSTRACT

INTRODUCTION: The aim of this study was to evaluate the torsional resistance, cyclic fatigue resistance, and bending stiffness of nickel-titanium (NiTi) file systems with different heat treatments and cross-sectional designs. METHODS: WaveOne Primary treated with memory-triple (MT) heat treatment (WOMT) was compared with WaveOne Primary (WO) and WaveOne Gold Primary (WOG). Torsional resistance test was performed using a customized device, and the distortion angle, ultimate strength, and toughness were evaluated. For cyclic fatigue resistance test, the instruments were reciprocated with continuous 4 mm up-and-down movement until fracture in a customized device, and the time to fracture was compared. Fracture surfaces of each group were examined under the scanning electron microscope. Bending stiffness was measured using a custom-made device. The results were analyzed using one-way analysis of variance and the Tukey's post hoc comparison at a significance level of 95%. RESULTS: WOMT showed higher ultimate strength and toughness than the other systems (P < .05). WOMT also showed highest cyclic fatigue resistance among the tested groups (P < .05). WO had the highest bending stiffness than others, whereas WOMT had a larger residual angle than others (P < .05). CONCLUSIONS: This new MT heat treatment technique makes NiTi file more flexible and improves its mechanical properties. In addition, the effect of heat treatment on flexibility was found to be more significant than that of the cross-sectional area.


Subject(s)
Alloys , Hot Temperature , Titanium , Nickel , Dental Instruments , Equipment Design , Root Canal Preparation , Stress, Mechanical , Materials Testing , Torsion, Mechanical
19.
Int Endod J ; 57(1): 100-107, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37886883

ABSTRACT

AIM: This study compared intracanal removal of filling as well as the frequency and volume of extruded material after retreatment with either HyFlex or Reciproc instruments in mandibular teeth from cadavers. METHODOLOGY: The root canals of 14 pairs of contralateral single-rooted teeth in mandibles of cadavers were instrumented with Reciproc R40 and filled using lateral compaction. The mandibles were scanned in a micro-computed tomographic (micro-CT) device before and after retreatment procedures. The contralateral teeth were assigned to two groups (n = 14) according to the retreatment protocol using either HyFlex or Reciproc instrument systems. In the HyFlex group, the HyFlex Remover instrument was worked 3 mm short of the working length (WL), followed by HyFlex CM 40.04 and 50.04 at the WL. In the Reciproc group, the R50 instrument was worked up at the coronal two thirds, followed by two more cycles until the WL was reached. Pre- and post-operative micro-CT images were analysed for extrusion and intracanal removal of filling material. RESULTS: After retreatment, extrusion of filling material occurred in 11 (78%) and 14 (100%) teeth from HyFlex and Reciproc groups respectively (p > .05). A similar volume of extruded material was observed after retreatment with both systems (p > .05). A significant decrease in the intracanal filling volume was verified after retreatment with both tested systems (p < .05). However, residual filling material was found in all root canals, regardless of the system. The amount of filling material removed (HyFlex = 80.8%; Reciproc = 65.9%) and the operation time was similar between systems (p > .05). CONCLUSIONS: A high frequency of filling material extrusion was observed after retreatment with the two systems in a cadaver model, with no significant difference between them. Both protocols obtained similar efficacy in filling material removal procedures, although none completely cleaned the canals.


Subject(s)
Root Canal Filling Materials , Humans , Gutta-Percha , Root Canal Obturation , Root Canal Preparation , Dental Instruments , Retreatment , X-Ray Microtomography/methods , Dental Pulp Cavity
20.
Int J Paediatr Dent ; 34(4): 474-484, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38124259

ABSTRACT

BACKGROUND: Paediatric rotary file systems have recently been developed for primary teeth use. AIM: To study the cleaning efficacies of two paediatric rotary endodontic files, the Prime PedoTM, and the Kedo-SG BlueTM against the standard H files. DESIGN: This in vitro study included 54 freshly extracted primary molars, which were randomised into three groups (n = 18 each) and were prepared using either Kedo-SG BlueTM, Prime PedoTM or hand H files after injecting methylene blue dye into the canals. Pre- and post-operative cone beam computerised tomography (CBCT) was performed to assess change in root canal volumes. Methylene blue dye removal from canals was assessed using stereomicroscopy, and canal cleanliness was examined by scanning electron microscopy (SEM). RESULTS: Both Prime PedoTM and Kedo-SG BlueTM files reduced significantly less dentine when compared with conventional hand filing with Prime PedoTM removing the least amount of dentine. No significant difference was found in median SEM scores among the groups in the cervical, middle and apical thirds of the roots. Stereomicroscopic assessment of root canal cleanliness using dye removal technique shows a statistically significant difference existing between Kedo-SG BlueTM and hand H files groups. CONCLUSION: Prime PedoTM removed the least amount of dentine. Kedo-SG BlueTM performed significantly better than conventional hand filing with H files when the root canal cleanliness was assessed.


Subject(s)
Dental Pulp Cavity , Microscopy, Electron, Scanning , Molar , Root Canal Preparation , Tooth, Deciduous , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , In Vitro Techniques , Dental Instruments , Cone-Beam Computed Tomography , Equipment Design , Methylene Blue
SELECTION OF CITATIONS