Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 13.061
Filter
1.
BMC Oral Health ; 24(1): 657, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38840138

ABSTRACT

BACKGROUND: Margin designs and loading conditions can impact the mechanical characteristics and survival of endocrowns. Analyzing the stress distribution of endocrowns with various margin designs and loading conditions can provide evidence for their clinical application. METHODS: Three finite element analysis models were established based on the margin designs: endocrown with a butt-joint type margin (E0), endocrown with a 90° shoulder (E90), and endocrown with a 135° shoulder (E135). The E0 group involved lowering the occlusal surface and preparing the pulp chamber. The E90 group created a 90° shoulder on the margin of model E0, measuring 1.5 mm high and 1 mm wide. The E135 group featured a 135° shoulder. The solids of the models were in fixed contact with each other, and the materials of tooth tissue and restoration were uniform, continuous, isotropic linear elasticity. Nine static loads were applied, with a total load of 225 N, and the maximum von Mises stresses and stress distribution were calculated for teeth and endocrowns with different margin designs. RESULTS: Compared the stresses of different models under the same loading condition. In endocrowns, when the loading points were concentrated on the buccal side, the maximum von Mises stresses were E0 = E90 = E135, and when there was a lingual loading, they were E0 < E90 = E135. In enamel, the maximum von Mises stresses under all loading conditions were E0 > E90 > E135. In dentin, the maximum von Mises stresses of the three models were basically similar except for load2, load5 and load9. Compare the stresses of the same model under different loading conditions. In endocrowns, stresses were higher when lingual loading was present. In enamel and dentin, stresses were higher when loaded obliquely or unevenly. The stresses in the endocrowns were concentrated in the loading area. In enamel, stress concentration occurred at the cementoenamel junction. In particular, E90 and E135 also experienced stress concentration at the shoulder. In dentin, the stresses were mainly concentrated in the upper section of the tooth root. CONCLUSION: Stress distribution is similar among the three margin designs of endocrowns, but the shoulder-type designs, especially the 135° shoulder, exhibit reduced stress concentration.


Subject(s)
Dental Stress Analysis , Finite Element Analysis , Stress, Mechanical , Humans , Dental Stress Analysis/methods , Dental Prosthesis Design , Crowns , Biomechanical Phenomena , Dentin
2.
J Contemp Dent Pract ; 25(3): 213-220, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690692

ABSTRACT

AIM: The objective of this study was to assess marginal bone level around single implants inserted in fresh extraction sockets in the anterior maxillary region and instantly restored with computer-aided design/computer-aided manufacturing customized temporary crowns cemented on the final abutment. MATERIALS AND METHODS: A total of 20 patients (15 females and 5 males, with a mean age of 30 years), where 20 were placed in fresh extraction sockets. After raising a full-thickness flap, atraumatic extraction was performed the implant site was prepared and fixtures were stabilized on the palatal bone wall. The implant location was immediately transmitted to the prepared master model using the pick-up impression coping seated in the surgical guide template. Prefabricated abutments were used as the final abutment on the master model, scanned and the crown was planned using computer-aided manufacturing customized software. Later on 8th weeks, abutments were torqued as per the manufacturer's recommendation, and the final crowns were cemented. Using personalized intraoral radiographs marginal bone level was evaluated mesially and distally to the implant shoulder as a reference at implant placement, 8 weeks, 1, 3, 5, and 10 years after loading. RESULTS: Wholly implants were osteo-integrated positively after 10 years of practical loading, but only 18 were available for clinical and radiological follow-up, and 2 patients with two implants were excluded from the study due to relocation abroad without any implant failure. The average marginal bone loss (MBL) in the current report was 0.16 ± 0.167 mm at crown cementation, 0.275 ± 0.171 mm after 1 year, 0.265 ± 0.171 mm after 3 years, 0.213 ± 0.185 mm after 5 years, and 0.217 ± 0.194 mm at 10 years. CONCLUSION: The strategy of inserting and not removing the final abutment at the time of implant placement facilitates the establishment of adequate attachment of both soft and hard tissues to the abutment surface, ensuring uninterrupted organization of tissue architecture and offers advantages in helping maintain soft tissue maturation and preventing marginal bone level. CLINICAL SIGNIFICANCE: Immediately loaded implants in freshly extracted sockets lead to a significant reduction in marginal ridge resorption. The use of a temporary crown on a prefabricated abutment, exclusive of successive abutment manipulation, proved effective in preserving the primarily founding blood clot and served as a prototype for shaping the soft tissue around the previously wounded gum. How to cite this article: Berberi A, El Zoghbi A, Aad G, et al. Immediate Loading Using the Digitalized Customized Restoration of Single-tooth Implants Placed in Fresh Extraction Sockets in the Aesthetic Anterior Maxilla: A 10-Year Prospective Study of Marginal Bone Level. J Contemp Dent Pract 2024;25(3):213-220.


Subject(s)
Computer-Aided Design , Crowns , Dental Implants, Single-Tooth , Immediate Dental Implant Loading , Maxilla , Tooth Socket , Humans , Male , Female , Prospective Studies , Maxilla/surgery , Adult , Immediate Dental Implant Loading/methods , Tooth Socket/surgery , Alveolar Bone Loss , Dental Abutments , Esthetics, Dental , Tooth Extraction , Dental Prosthesis, Implant-Supported , Dental Prosthesis Design , Dental Implant-Abutment Design , Young Adult
3.
Int J Esthet Dent ; 19(2): 140-150, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726856

ABSTRACT

The present technical article describes a protocol to digitally reproduce the emergence profile of an interim implant prosthesis (IP) and to transfer its macrogeometry into the definitive restoration. The purpose of this protocol was to minimize alterations in the gingival architecture developed during the interim restorative phase of a single implant that could potentially jeopardize its esthetic outcome. The process included obtaining an intraoral scan with the interim IP in situ, a duplicate of this intraoral scan that was used to capture the exact position of the implant, and an extraoral scan of the prosthesis. These data could then be imported into IOS software to create a model where the patients' soft tissue was incorporated with precision, allowing for the fabrication of a definitive crown with an optimal soft tissue adaptation. As there are few articles in the scientific literature that have reported a consistent method to replicate the emergence profile of an interim IP, the present technical article aims to highlight the potential of utilizing the emergence profile of an interim IP created by IOS software.


Subject(s)
Software , Humans , Esthetics, Dental , Computer-Aided Design , Crowns , Dental Prosthesis, Implant-Supported/methods , Dental Restoration, Temporary/methods , Dental Prosthesis Design/methods , Dental Implants, Single-Tooth
4.
Int J Esthet Dent ; 19(2): 186-194, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726859

ABSTRACT

OBJECTIVE: A diagnostic mock-up is a key tool that allows a preview of the outcome of an esthetic restoration. With recent developments in CAD/CAM technology, it is important to understand the pros and cons of chairside digital dentistry and the restorative materials used. The aim of the present case report is to describe in detail the use of a 3D-printed mock-up fabricated from a polymer-based material for an esthetic treatment plan within a fully digital workflow. CASE REPORT: A 45-year-old female patient presented at the clinic concerned about her esthetic appearance and the color of her anterior incisors. After a conclusive diagnosis, a restoration was planned using ceramic veneers from maxillary premolar to premolar. For a preview visualization of the outcome, an intraoral scanner was used to obtain 3D images and to allow the design of a digital smile. The template STL file was exported to a 3D printer and a 0.6-mm mock-up in A3-shade 3D resin was produced after 25 min. The mock-up was tested through a try-in and approved by the patient. As a result, the printed mock-up was considered predictable and reliable for the final restoration. CONCLUSIONS: The ease, speed, and reduced costs derived from the digital workflow, in conjunction with the accuracy of the mock-up, made the procedure highly efficient and recommendable.


Subject(s)
Computer-Aided Design , Esthetics, Dental , Printing, Three-Dimensional , Humans , Female , Middle Aged , Dental Veneers , Dental Prosthesis Design/methods , Ceramics , Incisor/diagnostic imaging
5.
Int J Esthet Dent ; 19(2): 197, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726861
6.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702708

ABSTRACT

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Subject(s)
Composite Resins , Computer-Aided Design , Dental Restoration Failure , Esthetics, Dental , Post and Core Technique , Humans , Ceramics , Dental Stress Analysis , Benzophenones , Incisor/injuries , Dental Materials/chemistry , Polyethylene Glycols , Ketones/chemistry , Polymers , Glass , Materials Testing , Dental Prosthesis Design
7.
J Clin Pediatr Dent ; 48(3): 59-67, 2024 May.
Article in English | MEDLINE | ID: mdl-38755983

ABSTRACT

The importance of aesthetics in children has increased over time. Therefore, this multicenter randomized clinical trial aimed to analyze and compare three-dimensional (3D)-printed resin crowns (RCs) as a potential alternative to stainless-steel crowns (SSCs) for restoring primary molars with extensive carious lesions. According to the null hypothesis, no statistically significant difference was observed in restoration failure between RC and SSC groups. A total of 56 primary molars after pulp treatment at two dental hospitals were included. After pulp treatment, the teeth were randomly divided into two groups: SSCs (n = 28) and RCs (n = 28). At 1 week and 3, 6 and 12 months, the Quigley-Hein plaque index (QHI), gingival index (GI), occlusal wear, and survival rate were assessed by examination, radiography and alginate impressions. No significant difference in QHI was observed between the two groups. However, the GI at 12 months and occlusal wear in the RC group were significantly higher than those in the SSC group (p < 0.05). The survival rates were 100% in the SSC group and 82.1% in the RC group (p = 0.047). Cracks and discoloration were also observed in the RCs. Within the limitations of this study, 3D-printed RCs are aesthetically superior to SSCs and clinically easy to repair. However, if clinical effectiveness and safety are improved, RCs could potentially become a viable aesthetic alternative in the future.


Subject(s)
Crowns , Molar , Printing, Three-Dimensional , Stainless Steel , Tooth, Deciduous , Humans , Female , Male , Child , Dental Caries/therapy , Dental Restoration, Permanent/methods , Child, Preschool , Dental Prosthesis Design , Periodontal Index , Dental Restoration Failure
8.
Br Dent J ; 236(10): 765-771, 2024 May.
Article in English | MEDLINE | ID: mdl-38789753

ABSTRACT

Current research has identified features of the prosthetic design with potential to significantly impact the long-term health of peri-implant tissues, while the choice of prosthetic components is also shown to be critical in an effort to reduce long-term complications of implant therapy. Overcontouring of the prosthesis emergence profile has been associated with marginal bone loss, recession and peri-implantitis, while the mucosal emergence angle is shown to have a strong association with peri-implant tissue inflammation. Further elements of interest include convexity/concavity of the restoration, the prosthetic connection and the different geometric configurations of junctions, as well as the peri-implant tissue dimensions. With regards to implant components, the choice between original and third-party-manufactured components might come with implications, as differences in material and microgeometry might impact precision of fit and overall performance, potentially leading to complications. Scrutiny of the specifications and manufacturing is essential when third-party-manufactured components are considered.The aim of this narrative review was to summarise the current evidence with regards to the restorative features of the implant prosthesis and also the selection of prosthetic components which can have implications for the long-term success of the implant therapy. Furthermore, the review aimed at interpretating current scientific evidence into meaningful strategies and recommendations to implement in clinical practice of implant dentistry.


Subject(s)
Dental Implants , Dental Prosthesis Design , Humans , Dental Implants/adverse effects , Peri-Implantitis/etiology , Peri-Implantitis/prevention & control
9.
Br Dent J ; 236(10): 753-757, 2024 May.
Article in English | MEDLINE | ID: mdl-38789751

ABSTRACT

The use of implants to replace missing teeth is now commonplace and practised by clinicians worldwide in both general and specialist practice. There is an abundance of evidence on the general success of implant treatment. As well as reviewing the history of dental implants, this narrative review will discuss the merits and successful placement of tissue-level verses bone-level implants. Furthermore, the article will evaluate the concept and benefits of platform switching for implant treatment. Finally, with the increased placement of implants, this narrative paper will review how different titanium surfaces impact on the risk of peri-implantitis.


Subject(s)
Dental Implants , Humans , Dental Implants/adverse effects , Peri-Implantitis/etiology , Peri-Implantitis/prevention & control , Dental Implantation, Endosseous/methods , Dental Prosthesis Design , Titanium
10.
Int J Prosthodont ; 37(7): 195-202, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787584

ABSTRACT

PURPOSE: To evaluate the fracture resistance of permanent resin crowns for primary teeth produced using two different 3D-printing technologies (digital light processing [DLP] and stereolithography [SLA]) and cemented with various luting cements (glass ionomer, resin-modified glass ionomer, and self-adhesive resin cement), whether thermally aged or not. MATERIALS AND METHODS: A typodont primary mandibular second molar tooth was prepared and scanned, and a restoration design was created with web-based artificial intelligence (AI) dental software. A total of 96 crowns were prepared, and 12 experimental groups were generated according to the cement type, 3Dprinting technology (DLP or SLA), and thermal aging. Fracture resistance values and failure types of the specimens were noted. The results were statistically analyzed with three-way ANOVA and Tukey HSD tests (α = .05). RESULTS: The results of the three-way ANOVA showed that there was an interaction among the factors (3D-printing technology, cement type, and thermal aging) (P = .003). Thermal aging significantly decreased the fracture resistance values in all experimental groups. DLP-printed crowns showed higher fracture resistance values than SLA-printed crowns. Cement type also affected the fracture resistance, with glass ionomer cement showing the lowest values after aging. Resin-modified glass ionomer and resin cements were more preferable for 3D-printed crowns. CONCLUSIONS: The type of cement and the 3D-printing technology significantly influenced the fracture resistance of 3D-printed permanent resin crowns for primary teeth, and it was decided that these crowns would be able to withstand masticatory forces in children.


Subject(s)
Crowns , Dental Restoration Failure , Printing, Three-Dimensional , Tooth, Deciduous , Humans , Resin Cements/chemistry , Dental Prosthesis Design , Dental Stress Analysis , Glass Ionomer Cements/chemistry , Dental Cements/chemistry , Materials Testing , Molar
11.
Int J Prosthodont ; 37(7): 175-185, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787582

ABSTRACT

PURPOSE: To assess the manufacturing accuracy, intaglio surface adaptation, and survival of resin-based CAD/CAM definitive crowns created via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS: A maxillary right first molar crown was digitally designed and manufactured using AM hybrid resin composite (VarseoSmile Crown Plus, Bego [AM-HRC]), AM glass filler-reinforced resin composite (Crowntec, Saremco Dental [AM-RC]), and SM polymer-infiltrated ceramic (Vita Enamic, VITA Zahnfabrik [SM-PICN]). Manufacturing accuracy (trueness and precision) was assessed by computing the root mean square (RMS) error (in µm; n = 15 per material). Intaglio surface adaptation was assessed by calculating the average gap distance (µm). Ten crowns from each group were cemented on fiberglass-reinforced epoxy resin dies and cyclically loaded to simulate 5 years of functional loading. One-way ANOVA, post hoc Bonferroni comparison tests, and Levene's test were used to analyze the data (α = .05). RESULTS: AM-RC had higher overall trueness than AM-HRC and SM-PICN (P ≤ .05), whereas the trueness of AM-RC on the external surface was similar to that of SM-PICN (P = .99) and higher than AM-HRC (P = .001). SM-PICN had lower precision than AM-RC and AM-HRC overall and at internal occlusal surfaces (P ≤ .05). Overall intaglio surface adaptation was similar between all groups (P = .531). However, for the axial intaglio surface, AM-RC and AM-HRC had higher adaptation than SM-PICN (P ≤ .05). All tested crowns survived the cyclic loading simulation of 5 years clinical use. CONCLUSIONS: AM-RC showed high manufacturing accuracy and adaptation. The tested resin-based CAD/CAM materials demonstrated clinically acceptable manufacturing accuracy and simulated medium-term durability, justifying the initiation of clinical investigations to determine their potential implementation in daily clinical practice.


Subject(s)
Composite Resins , Computer-Aided Design , Crowns , Dental Prosthesis Design , In Vitro Techniques , Composite Resins/chemistry , Humans , Dental Marginal Adaptation , Surface Properties , Materials Testing , Dental Stress Analysis , Ceramics/chemistry , Molar
12.
Int J Prosthodont ; 37(7): 227-241, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787588

ABSTRACT

PURPOSE: This position paper summarizes all relevant aspects of the use of working models derived from digital data in digital and hybrid workflows, aiming to (1) provide the reader with a comprehensive review of the types of models that currently can be produced from a digital file created by an intraoral scanner (IOS); (2) critically analyze issues that may undermine or compromise their reliability when requested for the fabrication of both tooth-borne and implant-supported fixed dental prostheses (FDPs); and (3) indicate the procedures to be implemented in order to overcome these issues and produce satisfactory restorations. MATERIALS AND METHODS: By way of a thorough literature review, the authors highlight the critical issues of milled and 3D-printed models, solid and alveolar, explaining the differences in terms of accuracy and reliability. RESULTS AND CONCLUSIONS: By describing the peculiarities of models with prepared natural teeth and those incorporating metal implant analogs, the clinical indications for their use are given while proposing the strategies that can be adopted to avoid errors during fabrication or to overcome inaccuracies.


Subject(s)
Computer-Aided Design , Models, Dental , Workflow , Humans , Printing, Three-Dimensional , Reproducibility of Results , Dental Prosthesis, Implant-Supported , Dental Prosthesis Design/methods
13.
Int J Prosthodont ; 37(7): 209-219, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787586

ABSTRACT

PURPOSE: The aim of this scoping review is to categorize 3D-printing applications of polymeric materials into those where there is evidence to support their clinical application and to list the clinical applications that require a greater evidence base or further development before adoption. MATERIALS AND METHODS: An electronic search on PubMed, EMBASE, Scopus (Elsevier), and Cochrane Library databases was conducted, including articles written in English and published between January 2003 and September 2023. The search terms were: ((3D printing) OR (3-dimensional printing) OR (three dimensional printing) OR (additive manufacturing)) AND ((polymer) OR (resin)) AND (dent*). Case reports, in vitro, in situ, ex vivo, or clinical trials focused on applications of 3D printing with polymers in dentistry were included. Review articles, systematic reviews, and articles comparing material properties without investigation on clinical application and performance/accuracy were excluded. RESULTS: The search provided 3,070 titles, and 969 were duplicates and removed. A total of 2,101 records were screened during the screening phase, and 1,628 records were excluded based on title/abstract. In the eligibility phase, of the 473 full-text articles assessed for eligibility, 254 articles were excluded. During the inclusion phase, a total of 219 studies were included in qualitative synthesis. CONCLUSIONS: There is lack of clinical evidence for the use of 3D-printing technologies in dentistry. Current evidence, when investigating clinical outcomes only, would indicate non-inferiority of 3D-printed polymeric materials for applications including diagnostic models, temporary prostheses, custom trays, and positioning/surgical guides/stents.


Subject(s)
Polymers , Printing, Three-Dimensional , Polymers/chemistry , Humans , Dentistry , Dental Prosthesis Design , Dental Materials/chemistry
14.
Int J Prosthodont ; 37(7): 275-284, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787592

ABSTRACT

Artificial intelligence (AI) has been expanding into areas that were thought to be reserved for human experts and has a tremendous potential to improve patient care and revolutionize the healthcare field. Recently launched AI-powered dental design solutions enable automated occlusal device design. This article describes a dental method for the complete digital workflow for occlusal device fabrication using two different AIpowered design software programs (Medit Splints and 3Shape Automate) and additive manufacturing. Additionally, the benefits and drawbacks of this workflow were reviewed and compared to conventional workflows.


Subject(s)
Artificial Intelligence , Computer-Aided Design , Software , Workflow , Humans , Dental Prosthesis Design , Occlusal Splints
15.
Int J Prosthodont ; 37(7): 243-252, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787589

ABSTRACT

Additive manufacturing (AM), also known as 3D printing, is gaining burgeoning interest among various dental disciplines. The import of this technology stems not only from its ability to fabricate different parts but from the solutions it provides for the customization and production of complex designs that other methods cannot offer-all to the end of enhancing clinical treatment alternatives. There is a wide range of AM machinery and materials available to choose from, and the goal of this review is to provide readers and clinicians with a decision tool for selecting the appropriate technology for a given application and to successfully integrate AM into the digital workflow.


Subject(s)
Printing, Three-Dimensional , Humans , Computer-Aided Design , Dental Prosthesis Design , Technology, Dental/trends
16.
Int J Prosthodont ; 37(7): 265-273, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787591

ABSTRACT

OBJECTIVES: To compare the positional trueness of implant-crown bonding to titanium bases (Ti-bases) using different bonding protocols. MATERIALS AND METHODS: A nonprecious alloy model with a single implant at the mandibular right first molar site was digitized, then a single implant crown was designed. The crown was milled, adhesively cemented on a Ti-base, and screw-retained on the implant in the master model to obtain a reference scan. Forty PMMA implant crowns were subtractively manufactured and allocated to one of four study groups (n = 10 crowns per group) based on the bonding protocol on Ti-bases: Group 1 = modelfree bonding; Group 2 = bonding on the master model (control); Group 3 = bonding on a model from an industrial-grade 3D printer (Prodways); Group 4 = bonding on a model from a conventional 3D printer (Asiga). To assess the positional trueness of crowns, the scans of crowns when on the model were superimposed over the reference scan. Median distance and angular deviations were analyzed using Kruskal-Wallis and Mann- Whitney tests (α = .05). Mesial and distal contacts of crowns were assessed by two independent clinicians. RESULTS: The control group (Group 2) resulted in the smallest distance deviations (0.30 ± 0.03 mm) compared to model-free (0.35 ± 0.02 mm; P = .002; Group 1) and conventional 3D printer (0.37 ± 0.01 mm; P = .001; Group 4) workflows. Buccolingual (P = .002) and mesiodistal (P = .01) angular deviations were higher in the conventional 3D printer group than in the control group (P = .002). Proximal contact assessments did not show any differences among groups. CONCLUSIONS: While bonding crowns to Ti-bases on a master model created with an industrial-grade 3D printer resulted in the highest positional trueness, model-free workflows had a similar positional trueness to those manufactured with a conventional 3D printer.


Subject(s)
Crowns , Dental Bonding , Dental Prosthesis Design , Titanium , Titanium/chemistry , Humans , Dental Bonding/methods , Dental Implants, Single-Tooth , Workflow , In Vitro Techniques , Computer-Aided Design , Dental Prosthesis, Implant-Supported , Printing, Three-Dimensional , Models, Dental
17.
Int J Prosthodont ; 37(7): 221-226, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38787587

ABSTRACT

PURPOSE: To evaluate fracture load values of five types of interim CAD/CAM crowns with and without thermocycling. MATERIALS AND METHODS: A complete coverage crown was designed on a mandibular first molar with a uniform 1.5-mm axial and occlusal reduction, and the STL file was exported to manufacture 100 crowns using five materials (20 crowns per material): ZCAD Temp Esthetic (SM-ZCAD; Harvest Dental); Telio CAD (SM-TCAD); P pro Crown and Bridge (AM-PPRO); E-Dent 400 C&B MHF (AM-EDENT); and DENTCA Crown & Bridge (AM-DENTCA). Each group was then divided into two subgroups: before and after thermocycling (10 cornws per subgroup). The STL file of the mandibular first molar die was used to manufacture 100 resin dies. Each die was assigned to one interim crown. Interim crowns were then luted to their assigned die using a temporary luting agent. The fracture strength of crowns was then assessed using a universal testing machine at a crosshead speed of 2 mm/minute. Two-way ANOVA followed by Tukey multiple comparations post-hoc tests were used to assess the effect of material choice and thermocycling process on the fracture strength of interim crowns (α = .05). RESULTS: Material choice and the thermocycling process exerted a significant (P < .001) impact on the fracture strength of interim crowns. However, the interaction between these two factors did not yield a statistically significant effect (P = .176). CONCLUSIONS: Within the limitations of this study, the type of interim materials and thermocycling process have a significant impact on the fracture strength of interim crowns.


Subject(s)
Computer-Aided Design , Crowns , Dental Prosthesis Design , Dental Stress Analysis , Materials Testing , Dental Restoration Failure , Humans , Molar
19.
Clin Exp Dent Res ; 10(3): e901, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770577

ABSTRACT

OBJECTIVES: The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments. MATERIAL AND METHOD: Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (n = 15): 50 µm alumina air-particle abrasion, silica coating using 30 µm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5-55°C) before debonding. The data obtained were analyzed using a two-way ANOVA. RESULTS: All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (p < .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode. CONCLUSIONS: All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.


Subject(s)
Aluminum Oxide , Silicon Dioxide , Surface Properties , Zirconium , Aluminum Oxide/chemistry , Humans , Silicon Dioxide/chemistry , Zirconium/chemistry , Molar , Materials Testing , Air Abrasion, Dental/methods , Resin Cements/chemistry , Dental Etching/methods , Dental Stress Analysis , Dental Prosthesis Design
20.
Am J Dent ; 37(2): 85-90, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38704851

ABSTRACT

PURPOSE: To evaluate clinical performances of two lithium disilicate systems (Initial LiSi press vs Initial LiSi Block, GC Co.) using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after 4 years of clinical service. METHODS: Partial adhesive crowns on natural abutment posterior teeth were made on 60 subjects who were randomly divided into two groups: Group 1: Initial LiSi press and Group 2: Initial LiSi Block. Fabrication of partial crowns was made with full analog and digital procedure in Groups 1 and 2 respectively. The restorations were followed-up for 1 and 4 years, and the modified USPHS evaluation was performed at baseline and each recall together with periodontal evaluation. Contingency tables to assess for significant differences of success over time in each group and time-dependent Cox regression to test for differences between the two groups were used and the level of significance was set at P< 0.05. RESULTS: Regarding modified USPHS scores, all evaluated parameters showed Alpha or Bravo and no Charlie was recorded. No statistically significant difference emerged between the two groups in any of the assessed variables (P> 0.05). No statistically significant difference between scores recorded at the baseline and each recall. All modified USPHS scores were compatible with the outcome of clinical success and no one restoration was replaced or repaired, and the survival rate was 100% after 4 years of clinical service. No difference was found between traditional and digital procedure to fabricate the crowns. The two lithium disilicate materials showed similar results after 4 years of clinical service. CLINICAL SIGNIFICANCE: The crowns made with the two tested lithium disilicate materials with analog and digital procedures showed 100% survival after 4 years of clinical service with no statistically significant difference using the modified USPHS scores.


Subject(s)
Crowns , Dental Porcelain , Humans , Dental Porcelain/chemistry , Male , Female , Adult , Middle Aged , Dental Prosthesis Design , Dental Restoration Failure , Follow-Up Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...