Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 752
Filter
1.
J Pak Med Assoc ; 74(5): 843-847, 2024 May.
Article in English | MEDLINE | ID: mdl-38783427

ABSTRACT

OBJECTIVE: To compare the effect of propolis and gluma desensitisers on the management of dentin hypersensitivity. METHODS: The single-blind, randomised controlled trial was conducted at the Department of Operative Dentistry, Dr Ishrat ul Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, from October 2020 to September 2021, and comprised patients with dentin hypersensitivity who had pain scores of at least 2 on the visual analogue scale. The teeth were randomised into propolis group A and Gluma group B. Baseline pain scores were assessed using visual analogue scale and Schiff's sensitivity scores and compared with scores immediately after the intervention, and then after one week and one month of the intervention. Data was analysed using SPSS 23. RESULTS: Of the 22 patients, 12(54.5%) were females and 10(45.4%) were males. Of the 80 teeth, there were 40(50%) in each of the 2 groups. Significant reduction was observed in dentin hypersensitivity immediately after the application of the desensitising agents (p<0.05). However, after one month, Gluma was more effective than propolis (p<0.05). CONCLUSIONS: Both Gluma and propolis were found to be effective desensitising agents, but the effectiveness of propolis decreased over one month. Clinical Trial Number: Clinical Trials.gov: NCT04819867.


Subject(s)
Dentin Desensitizing Agents , Dentin Sensitivity , Propolis , Humans , Propolis/therapeutic use , Dentin Sensitivity/drug therapy , Female , Male , Adult , Dentin Desensitizing Agents/therapeutic use , Single-Blind Method , Methacrylates/therapeutic use , Pain Measurement , Young Adult , Middle Aged , Glutaral
2.
BMC Oral Health ; 24(1): 562, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745306

ABSTRACT

BACKGROUND: Dentin hypersensitivity (DH) is one of the most challenging and persistent dental complaints characterized by transient, intense pain triggered by various stimuli. It affects a significant portion of the global population, predominantly those aged 20-40. This study aims to evaluate the desensitizing efficacy of seventh-generation dentin bonding agents (Single Bond Universal by 3 M ESPE and Xeno-V + by Dentsply) against a control group using Bifluorid 12 by Voco in mitigating DH within a month of the follow-up period. METHODS: This was a single-center, parallel-group, double-blind, controlled randomized clinical trial conducted at Dow University of Health Sciences, Karachi, Pakistan. A total of 105 patients with DH were allocated into three groups for this study. The patients were divided into three groups (Single Bond Universal by 3 M ESPE and Xeno-V + by Dentsply) and the control group containing fluoride varnish (Bifluorid 12 by Voco). Discomfort Interval Scale scores and Schiff Cold Air Sensitivity Scale scores were recorded at baseline, immediately after the intervention, after 01 weeks, and after 01 month. RESULTS: All the materials demonstrated a statistically significant reduction in discomfort and sensitivity (DIS scores p-value 0.01) immediately after 01 week and over a period of 01 month after treatment compared with the baseline scores before application, with no single material proving superior over the one-month observation period. The study also provided insights into dental hygiene practices, with a significant majority using a toothbrush and sensitivity patterns, with cold stimuli being the most common cause of sensitivity. CONCLUSION: The study demonstrates that Single Bond Universal, Xeno V+, and Bifluorid 12 are equally effective in reducing dentin hypersensitivity, with no distinct superiority observed over a one-month period. The findings highlight the potential of fluoride varnishes as a less technique-sensitive and cost-effective option for treating DH, offering valuable insights for future research and clinical practice. TRIAL REGISTRATION: NCT04225247 ( https://clinicaltrials.gov/study/NCT04225247 ), Date of Registration: 13/01/2020. (Retrospectively registered).


Subject(s)
Dentin Desensitizing Agents , Dentin Sensitivity , Dentin-Bonding Agents , Fluorides, Topical , Humans , Dentin Sensitivity/drug therapy , Female , Double-Blind Method , Male , Adult , Dentin Desensitizing Agents/therapeutic use , Dentin-Bonding Agents/therapeutic use , Fluorides, Topical/therapeutic use , Fluorides/therapeutic use , Young Adult , Bisphenol A-Glycidyl Methacrylate/therapeutic use , Treatment Outcome , Resin Cements/therapeutic use , Pain Measurement
3.
BMC Oral Health ; 24(1): 507, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38685035

ABSTRACT

BACKGROUND: Dentin hypersensitivity, often occurring after dental treatments or from erosive lesions, is a prevalent patient complaint. This study introduces a paste combining 8% L-arginine, calcium carbonate, and potassium nitrate to evaluate its impact on dentinal tubules occlusion, dentin permeability, and tooth sensitivity. METHODS: Dentin surfaces from 24 third molars (thickness: 2 mm) were divided into two groups of 12. One received the experimental paste, while the other received a placebo without desensitizer. Permeability and sealing ability were assessed through scanning electron microscopy (SEM) and dentin permeability measurement. The pastes' effects on hypersensitivity were then examined in a triple-blind, randomized parallel-armed clinical trial with 16 eligible patients. Sensitivity to cold, touch, and spontaneous stimuli was recorded using the VAS scale at various intervals post-treatment. Statistical analysis was conducted using Shapiro-Wilk, Mann-Whitney U, Friedman, and Wilcoxon tests (α = 0.05). RESULTS: The permeability test demonstrated a significant reduction in dentin permeability in the experimental group (P = 0.002) compared to the control (P = 0.178). SEM images revealed most dentinal tubules in the intervention samples to be occluded. Clinically, both groups showed a significant decrease in the three types of evaluated sensitivity throughout the study. However, no significant difference in sensitivities between the two groups was observed, with the exception of cold sensitivity at three months post-treatment (P = 0.054). CONCLUSION: The innovative desensitizing paste featuring 8% L-arginine, calcium carbonate, and potassium nitrate effectively occluded dentinal tubules and reduced dentin permeability. It mitigated immediate and prolonged dentin hypersensitivity to various stimuli, supporting its potential role in managing dentin hypersensitivity. TRIAL REGISTRATION: http://irct.ir : IRCT20220829055822N1, September 9th, 2022.


Subject(s)
Arginine , Calcium Carbonate , Dentin Desensitizing Agents , Dentin Sensitivity , Microscopy, Electron, Scanning , Nitrates , Potassium Compounds , Humans , Dentin Sensitivity/drug therapy , Arginine/therapeutic use , Calcium Carbonate/therapeutic use , Nitrates/therapeutic use , Male , Female , Potassium Compounds/therapeutic use , Dentin Desensitizing Agents/therapeutic use , Adult , Dentin Permeability/drug effects , Dentin/drug effects , Toothpastes/therapeutic use , Young Adult , Middle Aged
4.
Oper Dent ; 49(3): 253-261, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38632860

ABSTRACT

OBJECTIVE: The objective of this study was to compare the efficacy of Biosilicate and Duraphat in the treatment of dentin hypersensitivity (DH). METHODS AND MATERIALS: This clinical trial was conducted with young adults presenting DH. A visual analogue scale (VAS) was used to assess the level of pain, using volatile and tactile tests. Forty participants presenting two teeth with DH were included, and these teeth were divided into two groups according to the treatment: Biosilicate or Duraphat. Each product was randomly applied on one tooth per participant once a week for 4 weeks and evaluated every 15 days for 60 days after the last application. RESULTS: The mean and standard deviation (SD) of VAS values for the initial volatile sensitivity evaluation were 6.18 (1.99) and 6.08 (1.98) for the Biosilicate and Duraphat groups, respectively, and at the fourth week 0.48 (1.5) and 0.83 (1.58). After 60 days, the volatile sensitivity showed the following values: 0.63 (1.19) for Biosilicate and 1.03 (1.07) for Duraphat. The intragroup comparison showed a significant reduction of mean VAS values for DH-related pain assessed by volatile testing for both groups (p<0.001), and the assessment at the 60-day follow-up showed mean values statistically similar to those obtained at the end of treatment. Initial tactile sensitivity observed was 1.48 (2.39) for the Biosilicate and 1.4 (2.2) for the Duraphat group and at the 60-day follow-up 0.23 (0.73) and 0.15 (0.36), respectively, with significant statistical difference (p<0.002). When the reduction in tactile and volatile sensitivities between both groups was compared, no statistically significant difference was observed. CONCLUSION: This study indicated that both products were able to promote an important reduction in dentin hypersensitivity with similar results within a 60-day follow-up.


Subject(s)
Ceramics , Dentin Sensitivity , Fluorides, Topical , Humans , Dentin Sensitivity/drug therapy , Female , Male , Ceramics/therapeutic use , Young Adult , Adult , Fluorides, Topical/therapeutic use , Fluorides, Topical/administration & dosage , Pain Measurement , Treatment Outcome , Dentin Desensitizing Agents/therapeutic use
5.
Clin Oral Investig ; 28(3): 189, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38430338

ABSTRACT

OBJECTIVES: To assess color change efficacy and the adverse effects of varied over-the-counter (OTC) bleaching protocols. METHODOLOGY: The study included randomized clinical trials evaluating color changes from OTC bleaching agents. Nine databases were searched, including the partial capture of the grey literature. The RoB2 tool analyzed the individual risk of bias in the studies. Frequentist network meta-analyses compared treatments through common comparators (∆Eab* and ∆SGU color changes, and tooth sensitivity), integrating direct and indirect estimates and using the mean and risk differences as effect measures with respective 95% confidence intervals. The GRADE approach assessed the certainty of the evidence. RESULTS: Overall, 37 remaining studies constituted the qualitative analysis, and ten composed the meta-analyses. The total sample included 1,932 individuals. ∆Eab* was significantly higher in groups 6% hydrogen peroxide (HP) strips (≥ 14 h). ∆SGU was significantly higher in groups at-home 10% carbamide peroxide (CP) (≥ 14 h), followed by 6% HP strips (≥ 14 h) and 3% HP strips (≥ 14 h). At-home 10% CP (7-13 h) and placebo showed lower risks of tooth sensitivity without significant differences between these treatments. CONCLUSION: Considering the low level of evidence, OTC products presented satisfactory short-term effects on tooth bleaching compared to the placebo, with little to no impact on dentin hypersensitivity and gingival irritation. CLINICAL RELEVANCE: OTC products are proving to be practical alternatives for tooth whitening. However, patients should be advised about the possible risks of carrying out such procedures without professional supervision.


Subject(s)
Dentin Sensitivity , Tooth Bleaching Agents , Tooth Bleaching , Humans , Carbamide Peroxide , Color , Dentin Sensitivity/drug therapy , Hydrogen Peroxide , Hypochlorous Acid , Network Meta-Analysis , Nonprescription Drugs/adverse effects , Peroxides , Tooth Bleaching/adverse effects , Tooth Bleaching/methods , Tooth Bleaching Agents/adverse effects , Tooth Bleaching Agents/pharmacology , Urea
6.
Clin Oral Investig ; 28(4): 230, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38530474

ABSTRACT

OBJECTIVES: To compare the effectiveness of using a 0.454% stannous fluoride-containing dentifrice twice daily in relieving dentinal hypersensitivity (DH) in a Chinese population. MATERIALS AND METHODS: This was a single-centre, randomized, controlled, examiner-blind, three-treatment-arm, parallel-group study in participants with clinically diagnosed DH. Subjects who met inclusion criteria (n = 197) were randomly allocated into 3 groups: test group (n = 66)-using a 0.454% stannous fluoride-containing dentifrice twice daily; positive control group (n = 64)-using a 5.0% calcium sodium phosphosilicate-containing dentifrice twice daily; negative control group (n = 67)-using a 1150 ppm of NaF dentifrice twice daily. Status of DH was assessed at week 4 and week 8 by the same independent examiner. Changes from baseline in Schiff sensitivity score, tactile threshold and Dentine Hypersensitivity Experience Questionnaire (DHEQ) score were analysed using analysis of covariance models. The DHEQ evaluated subject-perceived oral health-related quality of life (OHRQoL). RESULTS: Statistically significant improvements in mean Schiff scores (p < 0.0001 for all products at Weeks 4 and 8), tactile threshold (p < 0.0001 for test and negative control at Weeks 4 and 8: Week 4 p = 0.0040 and Week 8 p < 0.0001 for positive control) and all DHEQ scores (p < 0.01 for all groups) were observed. No statistically significant differences were observed in the adjusted mean between all dentifrices at both timepoints, potentially driven by a placebo effect. Forty-two treatment-emergent adverse events (TEAEs) were reported (n = 32 subjects), with 2 serious AEs (n = 1) in the test group. TEAEs were not considered treatment-related. CONCLUSIONS: All groups demonstrated statistically significant improvements in Schiff score, tactile threshold and OHRQoL. However, due to a possible placebo effect in the negative control, there were no statistically significant differences between the dentifrices. CLINICAL RELEVANCE: This study adds to the growing research exploring why the placebo effect is a common phenomenon in DH studies. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04950465.


Subject(s)
Dentifrices , Dentin Desensitizing Agents , Dentin Sensitivity , Humans , Tin Fluorides , Dentifrices/therapeutic use , Sodium Fluoride/therapeutic use , Quality of Life , Treatment Outcome , Dentin Sensitivity/drug therapy , Phosphates/therapeutic use , Dentin Desensitizing Agents/therapeutic use , Double-Blind Method , Touch , China , Fluorides
7.
J Contemp Dent Pract ; 25(1): 52-57, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38514431

ABSTRACT

AIM: The aim of this study was to assess the impact of Nd:YAG laser, glutaraldehyde-based desensitizer (GD), or their combination on occluding dentinal tubules. MATERIALS AND METHODS: Fifty dentin samples were obtained from non-carious human third molars and randomly divided into five groups (n = 10): (1) Control group treated with 37% phosphoric acid, (2) GD group, (3) Nd:YAG laser group (1064 nm, 100 µs, 10 Hz, 300 µm fiber, 1 W power, 100 mJ energy, and 85 J/cm2 energy density), (4) GD followed by Nd:YAG laser group, and (5) Nd:YAG laser followed by GD group. Scanning electron microscopy (SEM) was used to capture five images from each sample for analysis of dentinal tubules using Image J software. SEM/EDX elemental analysis was performed to determine the main mineral contents. Data analyzed using one-way ANOVA and Tukey's post hoc test for statistical comparisons. RESULTS: Laser and combination groups showed a significant decrease in dentinal tubule counts compared with the control and GD groups (p < 0.0001). There were no significant differences in open dentinal tubule counts between the control and GD groups, as well as between the laser and combination groups. However, significant differences were observed in the total area, average size of the tubules, and percentage area between the control group and the treatment groups (GD, laser, GD + laser, laser + GD). No significant difference was found in the Ca/P ratio between the tested groups. CONCLUSION: The use of Nd:YAG laser alone or in combination with GD was more effective in occluding dentinal tubules compared to GD alone. CLINICAL SIGNIFICANCE: This study has shown that Nd:YAG laser alone and in combination with GD has superior dentinal tubule occlusion in vitro. Its clinical use in the treatment of dentinal hypersensitivity may overcome the drawback of conventional treatment approaches for dentin hypersensitivity needing repeated applications to achieve continuous relief from pain since acidic diet and toothbrushing result in the continuing elimination of precipitates and surface coatings. How to cite this article: Alzarooni AH, El-Damanhoury HM, Aravind SS, et al. Combined Effects of Glutaraldehyde-based Desensitizer and Nd: YAG Laser on Dentinal Tubules Occlusion. J Contemp Dent Pract 2024;25(1):52-57.


Subject(s)
Dentin Sensitivity , Lasers, Solid-State , Humans , Lasers, Solid-State/therapeutic use , Dentin , Dentin Sensitivity/drug therapy , Glutaral/pharmacology , Glutaral/therapeutic use , Molar, Third , Microscopy, Electron, Scanning
8.
J Mech Behav Biomed Mater ; 152: 106420, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38310812

ABSTRACT

OBJECTIVES: The dentin exposure always leads to dentin hypersensitivity and the acid-resistant/abrasion-resistant stability of current therapeutic approaches remain unsatisfatory. Inspired by the excellent self-polymerization/adherence activity of mussels and the superior mineralization ability of bioactive glass, a novel radial mesoporous bioactive nanoglass coated with polydopamine (RMBG@PDA) was developed for prevention and management of dentin hypersensitivity. METHODS: Radial mesoporous bioactive nanoglass (RMBG) was synthesized by the sol-gel process combined with the cetylpyridine bromide template self-assembly technique. RMBG@PDA was synthesized by a self-polymerization process involving dopamine and RMBG in an alkaline environment. Then, the nanoscale morphology, chemical structure, crystalline phase and Zeta potential of RMBG and RMBG@PDA were characterized. Subsequently, the ion release ability, bioactivity, and cytotoxicity of RMBG and RMBG@PDA in vitro were investigated. Moreover, an in vitro experimental model of dentin hypersensitivity was constructed to evaluate the effectiveness of RMBG@PDA on dentinal tubule occlusion, including resistances against acid and abrasion. Finally, the Young's modulus and nanohardness of acid-etched dentin were also detected after RMBG@PDA treatment. RESULTS: RMBG@PDA showed a typical nanoscale morphology and noncrystalline structure. The use of RMBG@PDA on the dentin surface could effectively occlude dentinal tubules, reduce dentin permeability and achieve excellent acid- and abrasion-resistant stability. Furthermore, RMBG@PDA with excellent cytocompatibility held the capability to recover the Young's modulus and nanohardness of acid-etched dentin. CONCLUSION: The application of RMBG@PDA with superior dentin tubule occlusion ability and acid/abrasion-resistant stability can provide a therapeutic strategy for the prevention and the management of dentin hypersensitivity.


Subject(s)
Calcinosis , Dentin Sensitivity , Humans , Dentin Sensitivity/drug therapy , Dopamine , Elastic Modulus , Dentin
9.
J Dent ; 143: 104877, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38316199

ABSTRACT

OBJECTIVE: This randomized controlled clinical trial evaluated the whitening efficacy, tooth sensitivity (TS), and volunteers' satisfaction following the use of activated charcoal powder and toothpaste. METHODS: Fifty-six volunteers were randomly allocated into 4 groups (n = 14) according to a 14-day toothbrushing or whitening treatment with activated charcoal powder (ACPW), activated charcoal toothpaste (ACT), regular fluoridated toothpaste (RT), and 10 % carbamide peroxide (CP). Objective (ΔE00) and subjective (ΔSGU) color and whiteness index (ΔWID) changes were calculated. Patients self-reported the risk and intensity of TS using a visual analogue scale and the volunteer's satisfaction was determined by a questionnaire. Color assessments were analyzed by Kruskal-Wallis followed by Dwas-Steel-Crithlow-Fligner, and absolute TS risk and volunteer's satisfaction by Fisher exact test (p < 0.05). RESULTS: ACPW and ACT promoted similar effects in ΔE00, ΔSGU, and ΔWID to that observed for RT. No significant difference was found in terms of TS risk intensity. TS risk became high after 7 and 14 days, with higher TS prevalence in CP. Volunteers reported that ACPW exhibited the lowest ease-of-use, comfort, and whitening satisfaction among groups (p < 0.05). CONCLUSION: Activated charcoal-based products presented a minor and unsatisfactory whitening effect while CP resulted in optimal tooth whitening and the highest level of satisfaction among volunteers. Risk was higher from 7 days onwards and was more pronounced in the CP. CLINICAL RELEVANCE: Based on the whitening effect and patient satisfaction, this controlled-randomized clinical evidence supports that the use of activated charcoal-based products should be discouraged.


Subject(s)
Dentin Sensitivity , Tooth Bleaching , Humans , Hydrogen Peroxide/therapeutic use , Charcoal/therapeutic use , Toothpastes/therapeutic use , Powders , Single-Blind Method , Tooth Bleaching/methods , Carbamide Peroxide , Dentin Sensitivity/drug therapy
10.
J Dent ; 144: 104898, 2024 May.
Article in English | MEDLINE | ID: mdl-38402943

ABSTRACT

OBJECTIVE: To assess the efficacy and safety of a toothpaste containing 7.5 % HX-BGC in combating dentinal hypersensitivity. METHODS: A single-center, randomized, double-blind, three-group parallel-controlled design was employed, with Schiff Index and Yeaple Index as measurement indicators. The study evaluated the effectiveness of HX-BGC toothpaste, NovaMin toothpaste, and a negative control toothpaste without desensitizing agents. Eligible subjects underwent baseline examination after a 2-week washout period, and those meeting inclusion criteria and not meeting exclusion criteria entered the study. Participants were randomly assigned to use one of the three toothpastes. Follow-up examinations were conducted immediately after a single use and at 2, 4, and 6 weeks. Intra-group and inter-group comparisons were made for Schiff and Yeaple indices. Safety of the experimental toothpastes was assessed through participant feedbacks and oral soft tissue examinations. RESULTS: Subjects in the three groups were balanced in terms of age and gender distribution, with no baseline differences in indicators. Immediately after a single application of toothpaste, Yeaple indices increased, and Schiff indices decreased, with no significant differences among the groups. After 2 weeks of continuous use, Yeaple indices increased in all groups, with significant differences observed between the HX-BGC group and the other two groups. Schiff indices decreased in all groups, with the NovaMin group showing significant differences compared to the negative control group. At weeks 4 and 6, both indices in the HX-BGC group and the NovaMin group were significantly better than those in the negative control group, with the HX-BGC group outperforming the NovaMin group in the Yeaple index. No serious adverse reactions related to the study products were observed or reported by any participants. CLINICAL SIGNIFICANCE: This clinical trial confirmed the efficacy of HX-BGC in anti-dentinal hypersensitivity and supported the clinical application of the dentifrice containing HX-BGC. CONCLUSION: Compared to the negative control group, both HX-BGC and NovaMin toothpaste groups demonstrated more significant effects in combating dentinal hypersensitivity. No adverse reactions related to the experimental toothpastes were observed.


Subject(s)
Ceramics , Dentifrices , Dentin Desensitizing Agents , Dentin Sensitivity , Toothpastes , Humans , Dentin Sensitivity/drug therapy , Double-Blind Method , Female , Male , Adult , Toothpastes/therapeutic use , Dentin Desensitizing Agents/therapeutic use , Ceramics/therapeutic use , Middle Aged , Dentifrices/therapeutic use , Treatment Outcome , Young Adult , Follow-Up Studies , Phosphates/therapeutic use , Glass , Safety , Fluorides/therapeutic use , China , East Asian People
11.
J Dent ; 142: 104868, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38301767

ABSTRACT

OBJECTIVE: To assess the clinical evidence for silver diamine fluoride (SDF) to reduce dentine hypersensitivity in adults. METHODS: Two independent researchers searched the English literature in five databases (Scopus, PubMed, Web of Science, EMBASE and the Cochrane Library) up to 15th July 2023 for clinical trials investigating the desensitising effect of professionally applied SDF to manage dentine hypersensitivity in adults aged 18 or above at any follow-up period. The primary outcome was the change in dentine hypersensitivity between baseline and follow-up visits after SDF application regarding any validated pain outcome measures. The Cochrane guidelines were used for the risk of bias assessment. RESULTS: Three hundred and thirty-one studies were identified, and four of them were finally included. Three of the included studies were rated as having a 'low risk' of bias. The SDF solution reduced dentine hypersensitivity in adults. The percentage reduction in dentine hypersensitivity ranged from 23 % to 56 % after a single application of SDF solution. Moreover, the SDF solution was more effective than potassium nitrate, potassium oxalate and glutaraldehyde plus hydroxyethyl methacrylate in reducing dentine hypersensitivity. Meta-analysis indicated a more significant reduction in visual analogue scales (1-10) by 1.35 (95 % CI:0.9-1.8; p<0.00001) after receiving the SDF application than controls. CONCLUSION: The included clinical trials showed that SDF solution reduced dentine hypersensitivity in adults. However, clinical trials are few, and their protocol varied from one another. Further well-designed clinical trials should be conducted to provide more evidence on its use to manage dentine hypersensitivity. CLINICAL SIGNIFICANCE: SDF is cleared as desensitizing agents by the US Food and Drug Administration to manage dentine hypersensitivity, which induces pain, limits food choice, and impacts the quality of life. Evidence from this systematic review informs clinicians and provides researchers insight for future research on SDF use for dentine hypersensitivity. THE INTERNATIONAL PROSPECTIVE REGISTER OF SYSTEMATIC REVIEWS (PROSPERO) REGISTRATION NUMBER: CRD42023462613.


Subject(s)
Dental Caries , Dentin Sensitivity , Humans , Cariostatic Agents/therapeutic use , Dental Caries/drug therapy , Dentin Sensitivity/drug therapy , Dentin Sensitivity/prevention & control , Fluorides, Topical/therapeutic use , Fluorides, Topical/pharmacology , Pain , Quality of Life , Quaternary Ammonium Compounds/therapeutic use , Quaternary Ammonium Compounds/pharmacology , Silver Compounds/therapeutic use , Silver Compounds/pharmacology
12.
Int Dent J ; 74(3): 559-565, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38184459

ABSTRACT

INTRODUCTION: The objective of this in vitro study was to compare the effectiveness of a propolis-based herbal toothpaste with 5% sodium fluoride varnishin obstructing human dentinal tubules; Scanning electron microscopy was utilised to obtain quantitative and qulitative data on tubular obstruction. METHODS: Thirty-nine extracted human premolar teeth were collected. The cementum layer was removed using a water-cooled diamond bur and the smear layer using ethylenediaminetetraacetic acid (EDTA) 17%. Then, the samples were randomly divided into 3 groups (n = 13 each), as follows: group 1: dentin discs exposed to the propolis-based herbal toothpaste (Herbex); group 2: dentin discs exposed to 5% sodium fluoride varnish; and group 3: control. Then, all discs were observed and imaged in 4 non-overlapping fields by an electron microscope at 2000× magnification. The topography and number of open, closed, and semi-closed tubules were counted in all images. The data were analysed using Kruskal-Wallis test, Mann-Whitney U test, and Friedman test. The statistical analysis was performed with SPSS statistic 22.0 software, with a significance level of α = 0.05. RESULTS: In pairwise comparisons of the groups considering the percentage of open, closed, and semi-closed tubules, the difference was not statistically significant between the 5% sodium fluoride varnish and propolis groups in the closed and semi-closed tubules, but it was statistically significant with the control group. Additionally, the percentage of open tubules in the propolis-based herbal toothpaste group was significantly lower than in the 5% sodium fluoride varnish and control group. CONCLUSIONS: Both propolis-based herbal toothpaste and 5% sodium fluoride varnish is effective in blocking human dentin tubules to various extents.


Subject(s)
Dentin Sensitivity , Fluorides, Topical , Microscopy, Electron, Scanning , Propolis , Sodium Fluoride , Toothpastes , Propolis/therapeutic use , Propolis/pharmacology , Humans , Toothpastes/therapeutic use , Sodium Fluoride/therapeutic use , Fluorides, Topical/therapeutic use , Dentin Sensitivity/prevention & control , Dentin Sensitivity/drug therapy , In Vitro Techniques , Dentin/drug effects , Dentin/ultrastructure , Dentin Desensitizing Agents/therapeutic use , Bicuspid
13.
J Am Dent Assoc ; 155(4): 304-311, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38244017

ABSTRACT

BACKGROUND: The authors evaluated the synergistic analgesic effect of preemptive administration of 400 mg of ibuprofen (IBU) and potassium fluoride 2% (KF2), both in isolation or combination, on the painful perception of tooth sensitivity after tooth bleaching. METHODS: Fifteen patients participated in this triple-blind, randomized, placebo-controlled clinical trial. The study used a crossover design for drug administration and a split-mouth design for desensitizer agent. Four paired groups were formed: IBU plus KF2 (IBU + KF2); IBU (IBU + placebo KF); KF2 (placebo IBU + KF2), and placebo (placebo IBU + placebo KF). The outcome measure was the perception of tooth sensitivity, assessed using a visual analog scale. Data were collected at 4 different times: immediately after tooth bleaching (baseline) and after 6, 30, and 54 hours. Statistical analysis was performed using the Friedman test and relative risk. RESULTS: IBU plus KF2 was found to be more effective in reducing tooth sensitivity immediately after bleaching (baseline) compared with the placebo group (P < .05). The risk of experiencing moderate or severe tooth sensitivity was approximately 4 times higher in the placebo group than in the IBU plus KF2 group (relative risk, 4.00; 95% CI, 1.01 to 15.81; P = .025). CONCLUSIONS: The combined use of 400 mg of IBU and KF2 appears to be beneficial in managing postbleaching tooth sensitivity. It provides a superior analgesic effect compared with placebo. PRACTICAL IMPLICATIONS: The preemptive administration of IBU plus KF2 reduces tooth sensitivity after tooth whitening when compared with placebo. This clinical trial was registered in the Brazilian Clinical Trials Registry Platform. The registration number is U1111-1249-8191.


Subject(s)
Dentin Sensitivity , Tooth Bleaching Agents , Tooth Bleaching , Humans , Ibuprofen/adverse effects , Dentin Sensitivity/etiology , Dentin Sensitivity/prevention & control , Dentin Sensitivity/drug therapy , Hydrogen Peroxide , Tooth Bleaching/adverse effects , Analgesics , Double-Blind Method , Treatment Outcome
14.
BMC Oral Health ; 24(1): 139, 2024 Jan 28.
Article in English | MEDLINE | ID: mdl-38281911

ABSTRACT

BACKGROUND: Light-cured resins are widely used as gingival barriers to protect the gums from highly concentrated peroxides used in tooth bleaching. The impact of barrier brand on clinical outcomes is typically considered negligible. However, there is limited evidence on the effects of different brands on operator experience, barrier adaptation, and patient comfort. OBJECTIVE: This clinical trial assessed the impact of four commercial gingival barrier brands (Opaldam, Topdam, Lysadam, and Maxdam) on operator perception, adaptation quality, and patient comfort. METHODS: Twenty-one undergraduate students placed gingival barriers in a randomized sequence using blinded syringes. Photographs of the barriers were taken from frontal and incisal perspectives. After bleaching procedures, operators rated handling features and safety using Likert scale forms. Two experienced evaluators independently assessed barrier adaptation quality on a scale from 1 (perfect) to 5 (unacceptable). The absolute risk of barrier-induced discomfort was recorded. Data were analyzed using Friedman and Chi-square tests (α = 0.05). RESULTS: Opaldam and Topdam received the highest scores in most handling features, except for removal, which was similar among all brands. No significant difference was observed in barrier adaptation quality between the evaluated brands. Discomforts were mainly reported in the upper dental arch, with Maxdam having the highest absolute risk (35% for this arch and 24% overall). CONCLUSIONS: This study suggests that gingival barrier brands can influence operator perception and patient comfort. Opaldam and Topdam were preferred by operators, but all brands demonstrated comparable adaptation quality. CLINICAL TRIAL REGISTRATION: The study was nested in a randomized clinical trial registered in the Brazilian Clinical Trials Registry under identification number RBR-9gtr9sc.


Subject(s)
Dentin Sensitivity , Tooth Bleaching Agents , Tooth Bleaching , Tooth , Humans , Dentin Sensitivity/chemically induced , Dentin Sensitivity/prevention & control , Dentin Sensitivity/drug therapy , Hydrogen Peroxide , Patient Comfort , Perception , Tooth Bleaching/adverse effects , Tooth Bleaching Agents/adverse effects , Treatment Outcome
15.
Minerva Dent Oral Sci ; 73(1): 20-26, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37943289

ABSTRACT

BACKGROUND: Dentin hypersensitivity is one of the most common complains faced by dental professionals, and there is still lack of consensus for the most effective treatment approaches. The aim of the present study was to evaluate the efficacy of ozone therapy combined with sodium fluoride in reducing pain associated with dental hypersensitivity, compared to a paint-on adhesive desensitizing agent. METHODS: The study included 20 patients (131 teeth), selected according to specific inclusion criteria and divided into two groups according to the type of desensitizing therapy (ozone with sodium fluoride or paint-on adhesive). The efficacy of both treatments were evaluated recording pain for each treated tooth immediately after treatment, after 1 month and after 6 months using a Numeric Rating Scale (NRS). Subjective parameters were also recorded: patients were asked to report whether they experienced pain caused by air, teeth brushing, cold and hot topical stimuli (present/absent). RESULTS: In both groups, pain values significantly decreased over time. Six months after treatment we registered significantly lower pain values in the ozone-treated group compared with the adhesive group and the mean percentage of NRS reduction from was significantly higher in the ozone-treated group. We did not register significant differences in subjective pain-related parameters between groups. CONCLUSIONS: The results of this exploratory study were aimed at exploring the combined effect of ozone with natrium fluoride, which was before described only in vitro. With the limitation of the sample size, our results suggest that this approach provides a pain reduction that was comparable to the paint-on adhesive.


Subject(s)
Dentin Sensitivity , Sodium Fluoride , Humans , Sodium Fluoride/therapeutic use , Dentin Sensitivity/drug therapy , Follow-Up Studies , Fluorides/therapeutic use , Pain
16.
Odontology ; 112(1): 272-278, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37354297

ABSTRACT

This study aims to evaluate the effect of Teethmate, Bifluoride 12, and Copal Varnish on the treatment of dentin hypersensitivity and the pulpal blood flow using laser Doppler flowmetry (LDF) after full crown preparations. Eighteen patients with 42 teeth with dentine hypersensitivity after full crown preparations were randomly treated with Teethmate, Bifluoride 12, and Copal Varnish. Dentine hypersensitivity was measured using a visual analog scale (VAS) and Schiff air index (SAI). LDF was used to assess the pulpal blood flow and results were recorded in perfusion units (PU). All measurements were performed at baseline, 5 min, 7 days, and 1 month after the application of desensitizers. Data were statistically analyzed by Wilcoxon and two-way ANOVA tests (p < 0.05). There was no significant difference between the tested desensitizers regarding VAS and PU values. VAS values decreased significantly at 7 days and 1 month after the application of desensitizers compared to baseline in all groups. The decrease in PU values significantly differed only in the Copal Varnish group at 5 min and 7 days after the application of the desensitizer (p < 0.05). A statistically significant difference was found between different times regarding SAI scores in all groups (p < 0.05). Teethmate, Bifluoride 12, and Copal Varnish showed similar effectiveness on dentine hypersensitivity and pulpal blood flow. Long-term clinical trials with larger sample sizes and histological studies are needed to evaluate their impacts on pulpal status.


Subject(s)
Dentin Sensitivity , Humans , Dentin Sensitivity/drug therapy , Laser-Doppler Flowmetry/methods , Sulindac/therapeutic use , Dental Pulp , Crowns
17.
Int J Biol Macromol ; 254(Pt 3): 127780, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37907172

ABSTRACT

Dentine hypersensitivity (DH) is a common oral health issue and occlusion of the exposed dentinal tubules (DTs) is regarded as the most effective therapeutic treatment nowadays. However, it is still difficult to develop easy and effective strategies for deep occlusion of DTs. In this study, we develop a strategy for occluding DTs deeply and compactly via simple application of occlusion media including (poly-L-aspartic acid)­strontium (PAsp­strontium) and phosphate/fluoride. The bonding of strontium ions to poly-L-aspartic acid formed a positively charged PAsp­strontium complexes. After application of 15 min each, the PAsp­strontium and phosphate/fluoride rapidly penetrated into the DTs in turn via the electrostatic interaction, then occluded the DTs with crystals up to a depth of 150 µm. The occlusion within DTs was resistant to abrasive and acidic challenges. The occlusion media performed better than commercial desensitizers Duraphat and Gluma. Moreover, this strategy possessed sufficient biocompatible and excellent performance in vivo. The application of occlusion media would shed light on in the management of DH.


Subject(s)
Dentin Sensitivity , Fluorides , Humans , Fluorides/chemistry , Strontium/chemistry , Dentin Sensitivity/drug therapy , Aspartic Acid/pharmacology , Phosphates , Dentin , Microscopy, Electron, Scanning
18.
Nanoscale ; 15(48): 19681-19690, 2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38037416

ABSTRACT

Dentin hypersensitivity treatment is not always successful owing to the exfoliation of the blocking layer. Therefore, efficiently delivering a desensitization agent into the dental tubule is critical. Nanomotors are widely used as in vivo drug delivery systems owing to their strong power and good biocompatibility. Herein, we report a kind of self-propelled bioglass Janus nanomotor with a Pt motion unit (nBGs@Pt) for application in dentin hypersensitivity that was prepared via a simple sol-gel method and magnetron sputtering method, with an average size of 290 nm. The Pt layer as the power unit provided the dynamics to deliver the bioglass (desensitization agent). Using hydrogen peroxide as a fuel, the nBGs@Pt could automatically move in different media. In addition, the nBGs@Pt with a mesoporous structure demonstrated good hydroxyapatite formation performance. An in vitro dentin pressure model was used to verify the blocking ability of the nBGs@Pt in dentin tubules. The dynamics of the nBGs@Pt was sufficient to resist the outflow of dentin fluid and movement into the dentin tubules, with a blocking rate of 58.05%. After remineralization, the blocking rate could reach 96.07% and the formation of hydroxyapatite of up to 10 µm or more occurred. It is expected that this study will provide a simple and feasible new strategy for the painless treatment of dentin sensitivity.


Subject(s)
Dentin Sensitivity , Humans , Dentin Sensitivity/drug therapy , Dentin , Ceramics/chemistry , Hydroxyapatites/therapeutic use
19.
Lasers Med Sci ; 38(1): 280, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38030798

ABSTRACT

This study aimed to investigate the effectiveness of erbium-doped yttrium garnet (Er:YAG) laser and GLUMA desensitizer for dentin hypersensitivity in teeth affected by Molar-Incisor Hypomineralization (MIH). One hundred twenty children were randomly allocated to four groups: the control (Co) group, the desensitizer (De) group, the laser (La) group, and the laser + desensitizer (La + De) group. Outcome measures included Visual Analogue Scale (VAS) and 14-item Oral Health Impact Profile (OHIP-14) evaluation. For mean VAS scores, a significant reduction was found over time in all groups. Co and De groups, Co and La groups, Co and La + De groups, De and La + De groups, and La and La + De groups differed significantly (p < 0.05). For mean scores in all dimensions of OHIP-14 after treatment 6 months, the La + De group was significantly lower (p < 0.001). The La + De groups and the La groups as well as the La + De groups and the De groups differed significantly in total OHIP, functional limitation, physical disability, and psychological disability (p < 0.05). Physical pain between the La + De groups and the La groups and handicap between the La + De groups and De groups differed significantly (p < 0.05). The mean values of each dimension differed significantly between the group Co and the La + De group (p < 0.0001). Combination therapy of Er:YAG laser and GLUMA desensitizer had greater desensitizing effects and oral health-related quality improvement of life, which might be an effective alternative treatment in dentin hypersensitivity in MIH children.


Subject(s)
Dentin Sensitivity , Laser Therapy , Lasers, Solid-State , Molar Hypomineralization , Humans , Child , Lasers, Solid-State/therapeutic use , Dentin Sensitivity/radiotherapy , Dentin Sensitivity/drug therapy , Dentin
20.
J Dent ; 139: 104749, 2023 12.
Article in English | MEDLINE | ID: mdl-37865271

ABSTRACT

OBJECTIVES: The effectiveness of three different groups of polyethylene glycol (PEG)-based gels containing powders on dentin hypersensitivity (DH) treatment were assessed and compared with Actimins® as commercial reference group. METHODS: Hydroxyapatite nanorods (nHA) and sol-gel-derived 45S5 bioglass (SGD 45S5) powders were synthesized through hydrothermal and sol-gel methods, respectively. First, 25 demineralized dentin disks were divided into five groups. Then, the prepared gels based on 45S5 bioglass with and without hydrolyzed casein (HC) as experimental, nHA gel and Actimins® as positive and commercial reference groups were applied twice a day on disks by a micro applicator. To mimic the oral environment, treated disks were immersed in artificial saliva in a water bath at 37 °C for 7 days. However, in the negative control group, no agent was applied on the samples. FE-SEM, EDS, AFM, and XRD were performed to assess tubule occlusion. One-way ANOVA test was used for statistical analysis and p*<0.05 was set as the significance level. RESULTS: The nHA with an average aspect ratio of 2.77 and the SGD 45S5 powders with a polygonal morphology and the average size of 48.64±11.38 µm were synthesized. After treatment, tubule occlusion in HC-SGD 45S5 and nHA gels were shown to be higher than other groups. The root mean square roughness (Rrms) of the above-mentioned gels showed to be 121.54±9.25 nm, and 312.6 ± 9 nm, respectively. CONCLUSION: The nHA containing group exhibited the highest tubule occlusion efficiency (i.e., tubule diameter of 0.92±0.32 µm) with a superior mineral precipitation. HC as a novel material demonstrates to be potentially beneficial in DH treatment. CLINICAL SIGNIFICANCE: DH as a common issue may be reduced or eliminated by occlusion of patent dentinal tubules. There are various types of desensitizing agents capable of controlling the DH by the occlusion of patent dentinal tubules. The desensitizing gels developed in this study showed to be promising for clinical and home-use applications.


Subject(s)
Dentin Desensitizing Agents , Dentin Sensitivity , Humans , Dentin , Dentin Sensitivity/drug therapy , Caseins/pharmacology , Caseins/therapeutic use , Glass , Gels/pharmacology , Gels/therapeutic use , Microscopy, Electron, Scanning , Dentin Desensitizing Agents/pharmacology , Dentin Desensitizing Agents/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...