Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.532
Filter
1.
J Oral Implantol ; 50(3): 266-276, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38839070

ABSTRACT

Patient satisfaction and quality of life are integral to assessing oral health care quality. For many Americans still using conventional complete dentures (CDs) or implant-retained mandibular overdentures (IODs), it remains essential to consider improving their oral health outcomes and quality of life. Due to inexperienced student dentists providing dental care to dental school patients, patient grievances are generally considered a problem. Patient feedback and satisfaction have proven valuable resources for monitoring and improving patient safety. While CDs and IODs are the 2 leading treatment options for edentulism, more comparative studies in the literature need to compare their outcomes in a school setting. The research question that guided this comparative analysis was, "Is patient satisfaction and quality of life affected by the type of prostheses and provider?" A validated questionnaire was mailed to 520 individuals selected from records of patients who had received treatment for edentulous mandible at a student prosthodontic clinic at the University of Kentucky College of Dentistry from 2014 to 2016 with at least 1 year of follow-up time. A validated questionnaire for edentulous patients based on the Oral Health Impact Profile (OHIP-19) was used. In addition, information on patients' oral health-related quality of life, including questions related to the edentulous patients' satisfaction with their dentures, was collected. The response rate was 33% (N = 171). The study's findings confirm previous findings, suggesting that IODs may significantly impact oral health-related quality of life. Data show that 76% of the IOD group reported improvement in experience when using the implants to retain the mandibular denture. However, there were no statistically significant differences in the OHIP scores between overall CD and IOD patient groups. Males with IODs had lower physical pain, limitations, and disability scores than males with CD. However, females with IODs reported more significant concerns associated with a social disability and handicap domains. Comparing users who had experiences with both treatment options, this study discerned essential characteristics that contribute to increased patient satisfaction with IODs and identified significance in outcomes by gender. These findings guide prosthodontic practitioners' patient care practices and identify a continuing need to discuss CD and IOD treatment protocols within dental school curricula.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Complete , Denture, Overlay , Patient Satisfaction , Quality of Life , Schools, Dental , Humans , Male , Female , Dental Prosthesis, Implant-Supported/psychology , Middle Aged , Surveys and Questionnaires , Aged , Dental Clinics , Adult , Jaw, Edentulous/rehabilitation
2.
BMC Oral Health ; 24(1): 672, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38851676

ABSTRACT

BACKGROUND: This crossover clinical study aimed to evaluate and compare masticatory performance and patient satisfaction for patients rehabilitated with conventional heat-cured acrylic resin and 3D-printed mandibular implant overdentures retained with bar attachment. MATERIALS AND METHODS: Sixteen completely edentulous healthy participants received new conventional dentures. In the mandible, four interforaminal implants were inserted. Following the stage of osseointegration, the bar was constructed in a trapezoidal configuration. Each patient randomly received the following overdentures using a crossover design: (1) conventional heat-cured acrylic resin overdenture and (2) 3D-printed overdenture (developed by scanning of mandibular conventional overdenture). The masticatory performance was assessed by conducting a two-colour mixing ability test at 5, 10, 20, 30, and 50 masticatory cycles. Moreover, the McGill Denture Satisfaction Questionnaire (MDSQ) was employed to assess patient satisfaction. Evaluation was performed after 3 months of using each overdenture. Paired sample t tests were used to compare the masticatory performance and MDSQ scores of patients for both prostheses. RESULTS: No significant difference in masticatory performance was reported between the two types of overdentures. Regarding patient satisfaction, only the esthetic aspect was significantly better for conventionally processed overdentures than for printed overdentures. Insignificant differences were observed regarding other MDSQ items between the two overdentures. CONCLUSION: Within this clinical study, 3D-printed implant overdentures showed promising results in terms of chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdentures. TRIAL REGISTRATION: Retrospectively registered at www. CLINICALTRIALS: gov : NCT06148727.(28/11/2023).


Subject(s)
Cross-Over Studies , Dental Prosthesis, Implant-Supported , Denture, Overlay , Mastication , Patient Satisfaction , Printing, Three-Dimensional , Humans , Mastication/physiology , Male , Female , Middle Aged , Aged , Mandible , Acrylic Resins
3.
Oral Health Prev Dent ; 22: 181-188, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38713458

ABSTRACT

PURPOSE: The objective of the present systematic review and meta-analysis was to assess randomised controlled trials (RCTs) which assessed the efficacy of mini dental implants (MDIs) and standard-diameter implants (SDIs) in retaining mandibular overdentures (MO). MATERIALS AND METHODS: The focused question was "Is there a difference in the mechanical stability between MDIs and SDIs in retaining MO?" Indexed databases were searched up to and including November 2023 using different keywords. Boolean operators were used during the search. The literature was searched in accordance with the PRISMA guidelines. The PICO characteristics were: patients (P) = individuals with complete mandibular dentures requiring dental implants; Intervention (I) = placement of MDIs under mandibular dentures; Control (C) = placement of SDIs under mandibular dentures; Outcome (O) = comparison of stability between MDIs and SDIs in supporting mandibular dentures. Only RCTs were included. Risk of bias (RoB) was assessed using the Cochrane RoB tool. RESULTS: Five RCTs were included. The numbers of participants ranged between 45 and 120 edentulous individuals wearing complete mandibular dentures. The mean age of patients ranged between 59.5 ± 8.5 and 68.3 ± 8.5 years. The number of MDIs and SDIs ranged between 22 and 152 and 10 and 80 implants, respectively. The follow-up duration ranged between one week and 12 months. Three RCTs reported an improvement in the quality of life (QoL) of all patients after stabilisation of mandibular dentures using MDIs or SDIs. In one RCT, peri-implant soft tissue profiles were comparable between MDIs and SDIs at the 1-year follow-up. The implant survival rate was reported in two RCTs, which were from 89% to 98% and 99% to 100% for MDIs and SDIs, respectively. All RCTs had a low RoB. CONCLUSION: Mini dental implants represent a viable alternative to traditional standard-diameter implants when seeking optimal retention for mandibular overdentures.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Denture Retention , Denture, Overlay , Randomized Controlled Trials as Topic , Humans , Mandible/surgery , Denture, Complete, Lower , Dental Prosthesis Design
4.
5.
Clin Oral Investig ; 28(6): 330, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38772987

ABSTRACT

OBJECTIVES: The aim of this multi-center pilot study was to assess the viability and feasibility of a novel treatment concept - the canine-positioned single implant mandibular overdenture (c-SIMO), with the single implant placed on the patient's preferred chewing side instead of the midline. MATERIALS AND METHODS: Participants received a single implant in the canine region of their preferred chewing side, based on an Asymmetry Index observed during mastication. The pre-existing mandibular denture was transformed into a c-SIMO on a spherical attachment. The primary outcome was oral health-related quality of life (OHRQoL), measured with GOHAI and OHIP-EDENT. Secondary outcomes included denture satisfaction index (DSI), chewing efficiency (CE), maximum bite force (MBF), implant survival and success, and prosthetic maintenance. Data analysis included descriptive statistics and bivariate comparison tests. RESULTS: Fifteen participants received the c-SIMO treatment (mean age: 69.9 ± 7.0). Implant success and survival rates were 100% at 1 year. Patient-reported outcome measures improved significantly compared to pre-treatment values (OHIP-EDENT: p = 0.001; DSI: p = 0.001; GOHAI: p = 0.002). Masticatory outcomes also improved significantly (CE: p = 0.001; overall MBF: p = 0.005). Post-implant, MBF was significantly higher in the ipsilateral side compared to the contralateral side at 2 weeks (p = 0.019) and 3 months (p = 0.015), but no longer at T3 (p = 0.730). Common prosthodontic events included denture base adjustments (n = 17) and matrix activation (n = 9). CONCLUSIONS: This pilot study concludes that c-SIMO is a promising treatment option, and a potential alternative to the single midline implant overdenture. CLINICAL RELEVANCE: The novel treatment concept of a canine-positioned single implant mandibular overdenture could be a viable treatment alternative to the midline positioning.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Overlay , Feasibility Studies , Mastication , Quality of Life , Humans , Pilot Projects , Aged , Male , Female , Mastication/physiology , Cuspid , Dental Implants, Single-Tooth , Patient Satisfaction , Middle Aged , Mandible , Denture Design
6.
Eur J Prosthodont Restor Dent ; 32(2): 183-193, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38691584

ABSTRACT

INTRODUCTION: The purpose of this in vitro study was to evaluate the dimensional accuracy, trueness, and precision of vinyl siloxane ether (VSXE) and polyvinylsiloxane (PVS) impression materials using different impression techniques. MATERIAL AND METHODS: A three-dimensional (3D) printed mandibular model with implants and metal rods served as the reference model. Impressions were taken in custom trays, resulting in four groups: PVS-closed-tray, VSXE-closed-tray, PVS-open-tray, and VSXE-open-tray. The reference model and impressions were scanned and analyzed using 3D analysis software to assess the trueness and precision within each group. RESULTS: There was significant difference in trueness between the groups, with PVS closed tray showing a higher deviation than VSXE-closed-tray and PVS-open-tray. VSXE-open-tray had the lowest deviation, which was statistically significant. In terms of precision, PVS-closed-tray showed the highest deviation, while no significant differences were found among the other groups. CONCLUSIONS: VSXE impression material with an open tray technique consistently demonstrated the highest levels of accuracy and precision. Conversely, PVS impression material with a closed tray technique yielded less favorable results. CLINICAL RELEVANCE: Better understanding of trueness and precision of new impression materials with new impression techniques will increase their clinical effectiveness.


Subject(s)
Dental Impression Materials , Dental Impression Technique , Denture, Overlay , Mandible , Polyvinyls , Siloxanes , Dental Impression Materials/chemistry , Siloxanes/chemistry , Humans , Dental Prosthesis, Implant-Supported , Printing, Three-Dimensional , In Vitro Techniques , Models, Dental
8.
Int J Prosthodont ; 37(2): 153-156, 2024 04 22.
Article in English | MEDLINE | ID: mdl-38648163

ABSTRACT

PURPOSE: To assess the effectiveness of converting a conventional mandibular denture (CMD) into a single-implant mandibular overdenture (SIMO). MATERIALS AND METHODS: Edentulous patients received a new CMD and were randomly assigned to the CMD or SIMO group. For SIMO patients, a midline early-loaded implant was inserted and incorporated into the CMD after 3 weeks. Patient satisfaction and oral health-related quality of life were assessed at baseline and up to 1 year. Regression models were constructed using Generalized Estimating Equation (GEE). RESULTS: After 12 months, 32 patients were assessed (CMD: n = 17; SIMO: n = 15). Significant improvement was observed for the SIMO group compared to baseline measures. CONCLUSIONS: SIMO may be considered an effective alternative for patients unsatisfied with their CMDs.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Complete, Lower , Denture, Overlay , Patient Satisfaction , Quality of Life , Humans , Male , Female , Aged , Middle Aged , Treatment Outcome , Jaw, Edentulous/rehabilitation , Mandible , Immediate Dental Implant Loading
9.
J Dent ; 145: 104982, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38583644

ABSTRACT

OBJECTIVES: To report the implant survival rates, clinical, and radiographic status after a period of more than 5 years in the function of 4 inter-foraminal implants retaining mandibular overdentures (OVDs) in individuals with T2DM. METHODS: 78 completely edentulous participants with type 2 diabetic mellitus (T2DM) who had worn mandibular OVDs retained by 4 inter-foraminal implants for long-term functional life were selected for this study. The participants were divided into 2 groups according to glycosylated haemoglobin A1c (HbA1c) levels before implant placement: group I with an HbA1c value > 6.5 % (inadequately controlled T2DM), and group II with an HbA1c value ≤6.5 % (well-controlled T2DM). The inadequately controlled T2DM was further subdivided into 2 groups: Group IA with an HbA1c value > 6.5 % and ≤8 % (moderately controlled), and Group IB has an HbA1c value > 8 % (poorly controlled). Implant survival rate, plaque index (PI), bleeding on probing (BOP), probing depth (PD), and radiographic crestal bone level (CBL) around implants were measured. RESULTS: Among 312 implants, 6 failed, 4 in well-controlled diabetics, and 2 in inadequately controlled diabetics. The overall survival rate was 98.07 %. The mean PI in group Ι was 36.4 (group IA =37.76, group IB = 34.27), and in group ΙΙ it was 19. The mean BOP in group Ι was 45.5 (group IA =47.84, group IB = 41.76), and in group ΙΙ it was 22. The mean PD in group Ι was 4.1 (group IA =4.3, group IB = 3.85) and in group ΙΙ was 2.2. The mean radiographic CBL in group Ι was 3.4 (group IA =3.7, group IB = 2.9), and in group ΙΙ was 1.5. Group IA exhibited a significantly greater level of PI, BOP, PD, and CBL compared to group IB and group IΙ (P1=0.017, P2=0.001). CONCLUSIONS: Individuals with T2DM can benefit from 4 inter-foraminal implants retained mandibular OVDs, and their inability to maintain proper glucose control may not exclude implant success. CLINICAL SIGNIFICANCE: This study is a significant step toward improving knowledge of options available for treatment and anticipated outcomes for T2DM completely edentulous populations undergoing implant therapy.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Denture, Overlay , Diabetes Mellitus, Type 2 , Glycated Hemoglobin , Mandible , Humans , Diabetes Mellitus, Type 2/complications , Male , Glycated Hemoglobin/analysis , Female , Retrospective Studies , Middle Aged , Mandible/diagnostic imaging , Mandible/surgery , Aged , Treatment Outcome , Dental Plaque Index , Periodontal Index , Alveolar Bone Loss/diagnostic imaging , Denture, Complete, Lower , Denture Retention , Dental Restoration Failure , Jaw, Edentulous/diagnostic imaging
11.
Shanghai Kou Qiang Yi Xue ; 33(1): 90-96, 2024 Feb.
Article in Chinese | MEDLINE | ID: mdl-38583032

ABSTRACT

PURPOSE: To observe the long-term clinical effect of implants retained complete overdentures with Locator attachments. METHODS: A total of 48 patients with edentulous jaws treated with implants retained complete overdentures with Locator attachments were selected from the Outpatient Department of Peking University School and Hospital of Stomatology from 2016 to 2017. Among them, 21 patients underwent double-maxillary complete overdentures restoration and 27 patients underwent single-maxillary restoration. A total of 230 implants were implanted. The clinical observation indicators included the implant survival rate, peri-implant mucosal bleeding on probing(BOP), the change in the vertical height of alveolar bone absorption around the implants, overdenture base fracture rate, artificial tooth fall off and fracture rate and other complications. The change of the locator attachment retention force of the implant-supported overdentures was evaluated. SPSS 13.0 software package was used for data analysis. RESULTS: During the five-years clinical observation period, 5 implants fell off, 1 narrow dimeter implant in the anterior zone was broken, and 12 implants were lost to follow-up. The implant survival rate was 97.25%. One year after the restoration therapy finished, peri-implant mucosal bleeding on probing (BOP+) was detected in 48 (21.4%) implants. The average BI was 0.21±0.42, which was higher in the anterior zone than that in the posterior zone. The vertical alveolar bone absorption height around the implants was (0.21±0.35) mm, 2 implants-supported complete overdenture bases were broken. After 5 years of restoration, 163(76.89%) implants had peri-implant mucosal bleeding on probing(BOP+). The average BI was 1.00±0.70, and the vertical alveolar bone absorption height around the implants was (0.58±0.85) mm. There was no significant difference between males and females. There was no significant difference in the peri-implant mucosal bleeding index and the alveolar bone vertical absorption height between the anterior zone and the posterior zone(P>0.05). The mean BI of peri-implant mucosa and the vertical absorption height of peri-implant alveolar bone were significantly different between the 1-year observation period and the 5-year observation period respectively(P<0.01). There were 17(26.15%) cases with overdenture bases fracture, and the fracture rate of artificial teeth was 16.92%. Most of them occurred in the midline area of the anterior zone and the location of the overdenture base on the locator attachments. The average first replacement time of the locator attachment nylon retainer washer was 34.2±10.3 months. CONCLUSIONS: Implants retained complete overdentures with Locator attachments are effective in long term clinical observation. Complications are mainly found in peri-implant mucosal bleeding on probing and vertical alveolar bone absorption, and tended to increase gradually over time. The fracture of the implant retains complete overdenture bases and the fall off or fracture of the artificial teeth are the second serious complications. Overdenture base with metal frame at the location of the Locator abutment and the midline of the anterior area should be strengthened, and narrow diameter implants should be avoided as far as possible in the anterior zone.


Subject(s)
Dental Implants , Jaw, Edentulous , Male , Female , Humans , Denture, Overlay , Dental Prosthesis, Implant-Supported/adverse effects , Denture Retention , Mandible/surgery , Dental Implants/adverse effects
12.
Trials ; 25(1): 267, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627819

ABSTRACT

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Subject(s)
Dental Implants , Jaw, Edentulous , Humans , Aged , Middle Aged , Denture, Overlay , Workflow , Mandible/surgery , Patient Satisfaction , Printing, Three-Dimensional , Dental Prosthesis, Implant-Supported , Randomized Controlled Trials as Topic
13.
Medicina (Kaunas) ; 60(4)2024 Mar 31.
Article in English | MEDLINE | ID: mdl-38674234

ABSTRACT

Background and Objectives: Despite the identified benefits of early implant loading, studies have questioned its advantages compared to delayed loading in edentulous patients. This study aimed to evaluate clinical peri-implant parameters and marginal bone loss around early placed and loaded mandibular implant overdentures with a 60-month follow-up. Materials and Methods: In this prospective cohort study, 43 patients were enrolled to receive 86 early loading sub-crestal dental implants through prosthetic guides. Implant overdentures were supported by two isolated implant locator attachments between two mental foramens. Clinical peri-implant parameters, including plaque index (PI), bleeding index (BI), peri-implant pocket depth (PIPD), and marginal bone loss (MBL) were evaluated using standardized techniques at 1, 12, 24, 36, 48, and 60 months follow-up. At 60 months, complications associated with implant overdentures (IOD's) were noted. The mean comparison of peri-implant clinical parameters was performed through ANOVA test. A p-value of ≤0.05 was taken as significant. Results: Out of the total 43 enrolled patients, 8 patients were lost during follow-up; as a result, 35 patients completed the 5 years follow-up. The mean values of PI, BI, and PIPD increased with no statistical difference (p > 0.05). For marginal bone loss, an increase in the mean values was noted at different time intervals with statistical differences (p < 0.001). The most common complications noted were loosening of the abutment, occlusal adjustment, retentive locator loosening and replacement, and relining of the denture. Conclusions: Early placement of IODs failed to prevent bone loss over time and was associated with complications, predominantly consisting of abutment loosening, occlusal adjustments, broken retentive locator components, relining, and rebasing.


Subject(s)
Alveolar Bone Loss , Denture, Overlay , Mandible , Humans , Female , Male , Prospective Studies , Alveolar Bone Loss/etiology , Middle Aged , Follow-Up Studies , Mandible/surgery , Aged , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis, Implant-Supported/adverse effects , Dental Implants/adverse effects , Cohort Studies , Adult
14.
Photodiagnosis Photodyn Ther ; 46: 104050, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38548040

ABSTRACT

OBJECTIVE: The aim was to systematically review clinical studies that investigated the efficacy of antimicrobial photodynamic therapy (aPDT) in reducing oral yeasts growth (OYG) in individuals wearing implant overdentures (IO). METHODS: The focused question was "Is aPDT effective in reducing OYG in patients wearing IO?" Literature search was performed in accordance with PRISMA guidelines. Indexed databases were searched without time and language restrictions up to and including January 2024. Clinical studies were included; and letters to the Editor, case-reports/case-series, perspectives/commentaries, in-vitro/ex-vivo studies, studies on animal models and expert opinions were excluded. The risk of bias was also assessed. RESULTS: Two clinical studies were included and processed for data extraction. The study population comprised of 100 (mean age: 58.5 years) and 53 (mean age: 58.5 years) individuals. The numbers of males and females included in these studies ranged between 33 and 35 males and 18-67 females, respectively. In both studies, follow-up evaluations were performed after 60 days. In both studies, aPDT was performed using a 660 nm diode laser at a power of 100 mW and using methylene-blue as photosensitizer. Results from both studies showed that aPDT is effective in significantly reducing oral yeasts CFU/ml and improvement of OHRQoL of individuals using IO. CONCLUSION: The aPDT is useful in reducing OYG on IO; however, further well-designed and power-adjusted studies are needed in this area of research.


Subject(s)
Denture, Overlay , Photochemotherapy , Photosensitizing Agents , Photochemotherapy/methods , Humans , Photosensitizing Agents/pharmacology , Photosensitizing Agents/therapeutic use , Methylene Blue/pharmacology , Methylene Blue/therapeutic use , Lasers, Semiconductor/therapeutic use , Yeasts/drug effects , Clinical Trials as Topic
15.
BMC Oral Health ; 24(1): 405, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38555452

ABSTRACT

OBJECTIVE: To assess stress distribution in peri-implant bone and attachments of mandibular overdentures retained by small diameter implants, and to explore the impact of implant distribution on denture stability. METHODS: Through three-dimensional Finite Element Analysis (3D FEA), four models were established: three models of a two mandibular implants retained overdenture (IOD) and one model of a conventional complete denture (CD). The three IOD models consisted of one with two implants in the bilateral canine area, another with implants in the bilateral lateral incisor area, and the third with one implant in the canine area, and another in the lateral incisor area. Three types of loads were applied on the overdenture for each model: a 100 N vertical load and a inclined load on the left first molar, and a100N vertical load on the lower incisors. The stress distribution in the peri-implant bone, attachments, and the biomechanical behaviors of the overdentures were analyzed. RESULTS: Despite different distribution of implants, the maximum stress values in peri-implant bone remained within the physiological threshold for all models across three loading conditions. The dispersed implant distribution design (implant in the canine area) exhibited the highest maximum stress in peri-implant bone (822.8 µe) and the attachments (275 MPa) among the three IOD models. The CD model demonstrated highest peak pressure on mucosa under three loading conditions (0.8188 Mpa). The contact area between the denture and mucosa of the CD model was smaller than that in the IOD models under molar loading, yet it was larger in the CD model compared to the IOD model under anterior loading. However, the contact area between the denture and mucosa under anterior loading in all models was significantly smaller than those under molar loading. The IOD in all three models exhibited significantly less rotational movement than the complete denture. Different implant positions had minimal impact on the rotational movement of the IOD. CONCLUSION: IOD with implants in canine area exhibited the highest maximum stress in the peri-implant bone and attachments, and demonstrated increased rotational movement. The maximum principal stress was concentrated around the neck of the small diameter one-piece implant, rather than in the abutment. An overdenture retained by two implants showed better stability than a complete denture.


Subject(s)
Dental Implants , Humans , Denture, Overlay , Finite Element Analysis , Denture, Complete , Mandible , Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Denture Retention
16.
Int J Implant Dent ; 10(1): 12, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38480586

ABSTRACT

PURPOSE: The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible. METHODS: From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up. RESULT: A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22). CONCLUSIONS: A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.


Subject(s)
Dental Implants , Jaw, Edentulous , Humans , Follow-Up Studies , Prospective Studies , Denture, Overlay , Quality of Life , Jaw, Edentulous/surgery , Mandible/surgery
17.
J Oral Rehabil ; 51(6): 1005-1015, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38475939

ABSTRACT

BACKGROUND: Graftless sinus floor augmentation shows good results in bone gain, radiology and implant survival. Clinically, this technique can be recommended as an alternative to conventional procedures using augmentation materials. OBJECTIVES: This study aims to assess masticatory performance, masticatory ability and patient satisfaction after graftless sinus floor augmentation. METHODS: The study group consisted of patients who had received a graftless sinus lift procedure in a split-mouth design and was compared to patients with maxillary implant-supported overdentures without augmentation and a natural dentition group. To assess objective masticatory performance, the mixing ability test was performed. Three questionnaires were used to assess patient reported outcomes related to mastication and patient satisfaction. RESULTS: Each group included ten patients. Both the graftless sinus lift group and the edentulous control group had a worse masticatory performance compared to the natural dentition group. Masticatory ability, measured by patient reported outcomes, was not different between the graftless sinus floor augmentation group and implant-retained overdentures group without augmentation, but the natural dentition group showed better results. Thereby, the better the masticatory performance in patients with a graftless sinus membrane elevation the better the patient satisfaction for 'prosthesis', 'appearance of prostheses', 'speech' and 'mastication and eating'. CONCLUSIONS: Patients with implant-supported overdentures show inferior masticatory function compared to those with natural dentition. There were no significant differences in masticatory performance between patients with implant-retained overdentures, with or without graftless augmentation. The decision on the preferred procedure should consider additional factors such as anatomical, surgical-technical aspects and patient's preferences.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Overlay , Mastication , Patient Satisfaction , Sinus Floor Augmentation , Humans , Mastication/physiology , Female , Male , Middle Aged , Sinus Floor Augmentation/methods , Aged , Mouth, Edentulous/rehabilitation , Mouth, Edentulous/surgery , Mouth, Edentulous/physiopathology , Treatment Outcome
18.
Int J Prosthodont ; 37(1): 49-58, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38381984

ABSTRACT

PURPOSE: To compare the biomechanical responses of a normal mandible to an osteoporotic mandible with two-implant-supported magnetic attachments. MATERIALS AND METHODS: A 3D finite-element model of a two-implant-supported mandibular overdenture with magnetic attachments was developed, and normal and osteoporotic bone samples were prepared. Four types of load were applied to the overdenture in each model: 100 N vertical and oblique loads on the right first molar, and a 100 N vertical load on the right canine and incisors. Biomechanical behaviors of the peri-implant bone, implant, and mucosa were recorded. Maximum equivalent stresses and elastic strains were analyzed. RESULTS: Equivalent elastic strain in osteoporotic cortical and cancellous bone was 9% to 71% and was 142% and 207% greater than in normal cortical bone, respectively. Equivalent elastic strain in the first molar oblique loading condition was 101% to 190% greater than in the first molar vertical loading condition. CONCLUSIONS: Osteoporotic cancellous bone was weaker and less resistant to deformation than normal bone, and oblique loading was more harmful than vertical loading.


Subject(s)
Dental Implants , Denture, Overlay , Finite Element Analysis , Dental Stress Analysis , Dental Prosthesis, Implant-Supported , Mandible , Magnetic Phenomena , Stress, Mechanical
19.
Int J Oral Maxillofac Implants ; 39(1): 127-134, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38416006

ABSTRACT

PURPOSE: To evaluate the precision and efficiency of a novel guide system for single implant placement in the mandibular symphyses and to evaluate whether the outcome is affected by the level of operator experience. MATERIALS AND METHODS: A total of 90 implants were placed in three different mandibular cast types (Cawood and Howell class III, IV, and V). For each model, a complete denture was 3D printed. A polyether ether ketone rail with a guide sleeve was embedded in the middle of the denture. To determine the ideal implant position, the sleeve could be moved in a buccolingual direction. Adjustment of implant angulation was possible, and an angle correction of 0, 12, or 24 degrees was available. A total of 30 clinicians were divided into three groups: group 1 (experienced, n = 10), group 2 (beginner, n = 10), and group 3 (inexperienced, n = 10). Each clinician was asked to plan and perform a guided flapless implant placement in the mandibular symphysis. Two preoperative CBCT scans were taken; the first was to verify the planning, and the second was to adjust the planning if needed. Finally, a postoperative CBCT scan was taken to compare the planning to the final implant position. RESULTS: Based on the first CBCT, the clinicians adjusted their planning by an average of 1.66 ± 1.65 mm coronally, 2.41 ± 2.44 mm apically, and by a mean angular correction of 6.08 ± 0.77 degrees. After implant placement, the mean deviation from the planned implant position was 0.87 ± 0.58 mm at the coronal aspect and 0.98 ± 0.64 mm at the apical aspect. The mean angular deviation was 6.05 ± 0.71 degrees. Overall, there were no significant differences in coronal and apical deviation (P > .05) based on the level of experience. In terms of angulation, a significant difference was found in both planning (P = .049) and placement (P = .038) between beginners and experienced clinicians. CONCLUSIONS: Guided implant placement of a single implant in the mandibular symphysis using a removable denture with guide sleeve had an acceptable level of accuracy. Clinicians with limited experience spent more time on the procedure, resulting in less angular deviation during implant planning and placement compared to experienced clinicians.


Subject(s)
Dental Implants , Denture, Overlay , Research Design , Denture, Complete , Mandible/surgery
20.
Oral Health Prev Dent ; 22: 107-114, 2024 02 20.
Article in English | MEDLINE | ID: mdl-38376434

ABSTRACT

PURPOSE: This study aimed to assess the impact of photodynamic therapy (PDT) on the oral health-related quality of life (OHRQoL) among denture stomatitis patients with implant overdenture prostheses (IODs). MATERIALS AND METHODS: The patients were recruited from a specialist dental practice according to selection criteria. The Candida spp. were identified and confirmed by the microbiological culture technique. Candida counts were estimated as colony-forming units (CFU/ml) at baseline, 15, 30, and 60 days. PDT was carried out twice a week with 72 h intervals for a period of 4 weeks. A structured questionnaire was used for data collection. It included the demographic details of the patients, including age, gender, education, marital and socioeconomic status (SES), oral habits, and smoking status. In addition, the Oral Health Impact Profile-EDENT (OHIP-EDENT) scale was added to assess the OHRQoL of all patients before and after PDT treatment. The data were analysed using descriptive statistics, the t-test and the Shapiro-Wilk test; statistical signifcance was set at p < 0.05. RESULTS: At baseline, the overall mean Candida CFU/ml were quite high in the implant overdenture (IODs) samples, 37.12 ± 15.8, as compared to palatal mucosa samples with 5.1 ± 2.3. After PDT treatment, a statistically significant reduction was noted in the mean Candida CFU/ml on both surfaces at all follow-up visits. It was observed that all domains of OHIP-EDENT except for physical disability and handicap showed statistically significant improvement in mean scores after PDT treatment. FL, P1, P2, D2, and D3 had statistically significant mean score improvements of 2.2, 3.1, 2.2, 1.4, and 0.7, respectively. Furthermore, after PDT treatment, the total OHIP-EDENT score showed a statistically significant improvement of 11.6. CONCLUSION: PDT treatment has a positive impact on the OHRQoL for patients with denture stomatitis. It can be used as an effective treatment option for the treatment of denture stomatitis in IOD patients.


Subject(s)
Dental Implants , Photochemotherapy , Stomatitis, Denture , Humans , Denture, Overlay , Quality of Life , Stomatitis, Denture/drug therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...