Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 6.681
Filter
1.
Oral Health Prev Dent ; 22: 181-188, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38713458

ABSTRACT

PURPOSE: The objective of the present systematic review and meta-analysis was to assess randomised controlled trials (RCTs) which assessed the efficacy of mini dental implants (MDIs) and standard-diameter implants (SDIs) in retaining mandibular overdentures (MO). MATERIALS AND METHODS: The focused question was "Is there a difference in the mechanical stability between MDIs and SDIs in retaining MO?" Indexed databases were searched up to and including November 2023 using different keywords. Boolean operators were used during the search. The literature was searched in accordance with the PRISMA guidelines. The PICO characteristics were: patients (P) = individuals with complete mandibular dentures requiring dental implants; Intervention (I) = placement of MDIs under mandibular dentures; Control (C) = placement of SDIs under mandibular dentures; Outcome (O) = comparison of stability between MDIs and SDIs in supporting mandibular dentures. Only RCTs were included. Risk of bias (RoB) was assessed using the Cochrane RoB tool. RESULTS: Five RCTs were included. The numbers of participants ranged between 45 and 120 edentulous individuals wearing complete mandibular dentures. The mean age of patients ranged between 59.5 ± 8.5 and 68.3 ± 8.5 years. The number of MDIs and SDIs ranged between 22 and 152 and 10 and 80 implants, respectively. The follow-up duration ranged between one week and 12 months. Three RCTs reported an improvement in the quality of life (QoL) of all patients after stabilisation of mandibular dentures using MDIs or SDIs. In one RCT, peri-implant soft tissue profiles were comparable between MDIs and SDIs at the 1-year follow-up. The implant survival rate was reported in two RCTs, which were from 89% to 98% and 99% to 100% for MDIs and SDIs, respectively. All RCTs had a low RoB. CONCLUSION: Mini dental implants represent a viable alternative to traditional standard-diameter implants when seeking optimal retention for mandibular overdentures.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Denture Retention , Denture, Overlay , Randomized Controlled Trials as Topic , Humans , Mandible/surgery , Denture, Complete, Lower , Dental Prosthesis Design
3.
J Mech Behav Biomed Mater ; 154: 106539, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38598917

ABSTRACT

PURPOSE: Polyetheretherketone (PEEK) is considered as an alternative to metal material for removable partial denture (RPD). However, the retentive force is not strong as a metal RPD. This study investigated the retention and fatigue performance of PEEK clasps with different proportions of clasp arm engaging the undercut to verify a new strategy to improve their clinical performance. METHODS: Three groups (n = 10/group) of PEEK clasps with their terminal 1/3, 2/3 and the whole of retentive arms engaging the undercut were fabricated along with a group (n = 10) of conventional cobalt-chrome (CoCr) clasps as control group. Retentive forces were measured by universal testing machine initially and at an interval of 1500 cycles for a total of 15,000 fatigue cycles. The fatigue cycles were conducted by repeated insertion and removal of the clasp using fatigue testing machine. Each clasp was scanned by Trios3 scanner before and after fatigue test to obtain digital models. The deformation of the clasp was evaluated by root mean square (RMS) through aligning the two models in Geomagic wrap (2021). Scanning electron microscopy (SEM) and finite element analysis were carried out to observe the abrasion and the von Mises stress of the clasp arm. Kruskal-Wallis H test was used to compare the retentive forces and the RMSs of the studied groups followed by Bonferroni multiple comparisons. RESULTS: The whole of PEEK clasp arm engaging the undercut provided higher mean retentive forces (7.99 ± 2.02 N) than other PEEK clasp groups (P < 0.001) and was closer to CoCr clasps (11.88 ± 2.05 N). The RMSs of PEEK clasps were lower than CoCr clasps (P < 0.05) while the differences among PEEK clasps were of no statistical significance (P > 0.05). SEM showed that evidences of surface abrasion were observed on the section that engaged the undercut for all groups of clasps. The stress concentration mainly occurred on the initial part of the retentive arm. The maximum von Mises stress of each group was below the compressive strength of PEEK. CONCLUSIONS: Proportions of PEEK clasp arm engaging the undercut positively influenced the retentive force and the fatigue resistance of PEEK clasps was superior than CoCr clasps. It is a feasible method to improve the retention of PEEK clasps by increasing the proportion of clasp arm engaging the undercut. Clinical trials are needed to further verify this innovation.


Subject(s)
Benzophenones , Denture Retention , Denture, Partial, Removable , Polyethylene Glycols , Polymers , Ketones , Chromium Alloys , Dental Stress Analysis , Dental Clasps
4.
BMC Oral Health ; 24(1): 473, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38641783

ABSTRACT

BACKGROUND: The establishment of good facial esthetics is one of the main objectives of complete denture construction. Unfortunately, it may be the caused issue for patients having a prominent premaxilla due to excessive lip support by the labial flange of the maxillary denture. Open-face dentures (OFD) may suggest suitable prosthetic management for these patients. However, clinical evidence regarding the efficiency of OFD is scarce. METHODS: A total of 38 completely edentulous participants having prominent premaxilla and skeletal class I Angle's classification were enrolled in this study. Each participant received a mandibular complete denture and 2 opposing maxillary dentures; conventional (CD) and open-face (OFD). On the day of denture insertion, the participants were divided into 2 groups; CD-OFD and OFD-CD where CD-OFD group was instructed to use the mandibular denture and the maxillary CD for 3 months and then to use the maxillary OFD for another 3 months after a wash-out period of 2 weeks. While group OFD-CD was instructed to use the mandibular denture and the maxillary OFD for 3 months then to use the maxillary CD for another 3 months after a wash-out period of 2 weeks. The dislodging force of the maxillary dentures was evaluated using the universal testing machine and the patient perception of retention, esthetics, and comfort was evaluated using the Visual Analogue Scale (VAS). Evaluation was carried out 1 day, 1 month, and 3 months after denture insertion. The Student t-test was used to compare the 2 maxillary dentures and the intervals for each denture were compared by using the ANOVA test with repeated measures followed by a Post Hoc test (adjusted Bonferroni) for pairwise comparison. RESULTS: The significance of the obtained results was judged at the 5% level (P value). The dislodging force and patient perception of retention did not show significant differences between the 2 dentures, while the perception of esthetics showed significant differences throughout the follow-up period. Perception of comfort showed an insignificant difference only at the 3-month interval. CONCLUSIONS: Open-face maxillary dentures can be a suitable alternative for patients with prominent premaxilla to achieve satisfactory retention, aesthetics, and comfort.


Subject(s)
Denture, Complete, Upper , Mouth, Edentulous , Humans , Cross-Over Studies , Denture Design/methods , Denture, Complete , Denture Retention , Patient Satisfaction
5.
J Dent ; 145: 104982, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38583644

ABSTRACT

OBJECTIVES: To report the implant survival rates, clinical, and radiographic status after a period of more than 5 years in the function of 4 inter-foraminal implants retaining mandibular overdentures (OVDs) in individuals with T2DM. METHODS: 78 completely edentulous participants with type 2 diabetic mellitus (T2DM) who had worn mandibular OVDs retained by 4 inter-foraminal implants for long-term functional life were selected for this study. The participants were divided into 2 groups according to glycosylated haemoglobin A1c (HbA1c) levels before implant placement: group I with an HbA1c value > 6.5 % (inadequately controlled T2DM), and group II with an HbA1c value ≤6.5 % (well-controlled T2DM). The inadequately controlled T2DM was further subdivided into 2 groups: Group IA with an HbA1c value > 6.5 % and ≤8 % (moderately controlled), and Group IB has an HbA1c value > 8 % (poorly controlled). Implant survival rate, plaque index (PI), bleeding on probing (BOP), probing depth (PD), and radiographic crestal bone level (CBL) around implants were measured. RESULTS: Among 312 implants, 6 failed, 4 in well-controlled diabetics, and 2 in inadequately controlled diabetics. The overall survival rate was 98.07 %. The mean PI in group Ι was 36.4 (group IA =37.76, group IB = 34.27), and in group ΙΙ it was 19. The mean BOP in group Ι was 45.5 (group IA =47.84, group IB = 41.76), and in group ΙΙ it was 22. The mean PD in group Ι was 4.1 (group IA =4.3, group IB = 3.85) and in group ΙΙ was 2.2. The mean radiographic CBL in group Ι was 3.4 (group IA =3.7, group IB = 2.9), and in group ΙΙ was 1.5. Group IA exhibited a significantly greater level of PI, BOP, PD, and CBL compared to group IB and group IΙ (P1=0.017, P2=0.001). CONCLUSIONS: Individuals with T2DM can benefit from 4 inter-foraminal implants retained mandibular OVDs, and their inability to maintain proper glucose control may not exclude implant success. CLINICAL SIGNIFICANCE: This study is a significant step toward improving knowledge of options available for treatment and anticipated outcomes for T2DM completely edentulous populations undergoing implant therapy.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Denture, Overlay , Diabetes Mellitus, Type 2 , Glycated Hemoglobin , Mandible , Humans , Diabetes Mellitus, Type 2/complications , Male , Glycated Hemoglobin/analysis , Female , Retrospective Studies , Middle Aged , Mandible/diagnostic imaging , Mandible/surgery , Aged , Treatment Outcome , Dental Plaque Index , Periodontal Index , Alveolar Bone Loss/diagnostic imaging , Denture, Complete, Lower , Denture Retention , Dental Restoration Failure , Jaw, Edentulous/diagnostic imaging
6.
Shanghai Kou Qiang Yi Xue ; 33(1): 90-96, 2024 Feb.
Article in Chinese | MEDLINE | ID: mdl-38583032

ABSTRACT

PURPOSE: To observe the long-term clinical effect of implants retained complete overdentures with Locator attachments. METHODS: A total of 48 patients with edentulous jaws treated with implants retained complete overdentures with Locator attachments were selected from the Outpatient Department of Peking University School and Hospital of Stomatology from 2016 to 2017. Among them, 21 patients underwent double-maxillary complete overdentures restoration and 27 patients underwent single-maxillary restoration. A total of 230 implants were implanted. The clinical observation indicators included the implant survival rate, peri-implant mucosal bleeding on probing(BOP), the change in the vertical height of alveolar bone absorption around the implants, overdenture base fracture rate, artificial tooth fall off and fracture rate and other complications. The change of the locator attachment retention force of the implant-supported overdentures was evaluated. SPSS 13.0 software package was used for data analysis. RESULTS: During the five-years clinical observation period, 5 implants fell off, 1 narrow dimeter implant in the anterior zone was broken, and 12 implants were lost to follow-up. The implant survival rate was 97.25%. One year after the restoration therapy finished, peri-implant mucosal bleeding on probing (BOP+) was detected in 48 (21.4%) implants. The average BI was 0.21±0.42, which was higher in the anterior zone than that in the posterior zone. The vertical alveolar bone absorption height around the implants was (0.21±0.35) mm, 2 implants-supported complete overdenture bases were broken. After 5 years of restoration, 163(76.89%) implants had peri-implant mucosal bleeding on probing(BOP+). The average BI was 1.00±0.70, and the vertical alveolar bone absorption height around the implants was (0.58±0.85) mm. There was no significant difference between males and females. There was no significant difference in the peri-implant mucosal bleeding index and the alveolar bone vertical absorption height between the anterior zone and the posterior zone(P>0.05). The mean BI of peri-implant mucosa and the vertical absorption height of peri-implant alveolar bone were significantly different between the 1-year observation period and the 5-year observation period respectively(P<0.01). There were 17(26.15%) cases with overdenture bases fracture, and the fracture rate of artificial teeth was 16.92%. Most of them occurred in the midline area of the anterior zone and the location of the overdenture base on the locator attachments. The average first replacement time of the locator attachment nylon retainer washer was 34.2±10.3 months. CONCLUSIONS: Implants retained complete overdentures with Locator attachments are effective in long term clinical observation. Complications are mainly found in peri-implant mucosal bleeding on probing and vertical alveolar bone absorption, and tended to increase gradually over time. The fracture of the implant retains complete overdenture bases and the fall off or fracture of the artificial teeth are the second serious complications. Overdenture base with metal frame at the location of the Locator abutment and the midline of the anterior area should be strengthened, and narrow diameter implants should be avoided as far as possible in the anterior zone.


Subject(s)
Dental Implants , Jaw, Edentulous , Male , Female , Humans , Denture, Overlay , Dental Prosthesis, Implant-Supported/adverse effects , Denture Retention , Mandible/surgery , Dental Implants/adverse effects
7.
BMC Oral Health ; 24(1): 405, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38555452

ABSTRACT

OBJECTIVE: To assess stress distribution in peri-implant bone and attachments of mandibular overdentures retained by small diameter implants, and to explore the impact of implant distribution on denture stability. METHODS: Through three-dimensional Finite Element Analysis (3D FEA), four models were established: three models of a two mandibular implants retained overdenture (IOD) and one model of a conventional complete denture (CD). The three IOD models consisted of one with two implants in the bilateral canine area, another with implants in the bilateral lateral incisor area, and the third with one implant in the canine area, and another in the lateral incisor area. Three types of loads were applied on the overdenture for each model: a 100 N vertical load and a inclined load on the left first molar, and a100N vertical load on the lower incisors. The stress distribution in the peri-implant bone, attachments, and the biomechanical behaviors of the overdentures were analyzed. RESULTS: Despite different distribution of implants, the maximum stress values in peri-implant bone remained within the physiological threshold for all models across three loading conditions. The dispersed implant distribution design (implant in the canine area) exhibited the highest maximum stress in peri-implant bone (822.8 µe) and the attachments (275 MPa) among the three IOD models. The CD model demonstrated highest peak pressure on mucosa under three loading conditions (0.8188 Mpa). The contact area between the denture and mucosa of the CD model was smaller than that in the IOD models under molar loading, yet it was larger in the CD model compared to the IOD model under anterior loading. However, the contact area between the denture and mucosa under anterior loading in all models was significantly smaller than those under molar loading. The IOD in all three models exhibited significantly less rotational movement than the complete denture. Different implant positions had minimal impact on the rotational movement of the IOD. CONCLUSION: IOD with implants in canine area exhibited the highest maximum stress in the peri-implant bone and attachments, and demonstrated increased rotational movement. The maximum principal stress was concentrated around the neck of the small diameter one-piece implant, rather than in the abutment. An overdenture retained by two implants showed better stability than a complete denture.


Subject(s)
Dental Implants , Humans , Denture, Overlay , Finite Element Analysis , Denture, Complete , Mandible , Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Denture Retention
8.
BMC Oral Health ; 24(1): 206, 2024 Feb 09.
Article in English | MEDLINE | ID: mdl-38336698

ABSTRACT

BACKGROUND: The various physical and chemical conditions within the oral cavity are hypothesized to have a significant influence on the behavior of denture adhesives and therefore the overall comfort of denture wearers. As such, this study aims to understand the influence of oral cavity physiological parameters such as temperature (17 to 52 °C), pH (2, 7, 10), and denture adhesive swelling due to saliva (20-120%) on the behavior of denture adhesives. This study further aims to emphasize the need for a collective approach to modelling the in-situ behavior of denture adhesives. METHODS: Rheological measurements were carried out using the Super Polygrip Ultra fresh brand denture adhesive cream to evaluate its storage modulus (G´) and loss modulus (G´´) values at a range of physiologically relevant temperatures, pH values, and degrees of swelling, to represent and characterize the wide variety of conditions that occur within the oral cavity. RESULTS: Rheological data was recorded with respect to variation of temperature, pH, and swelling. Overall, it can be seen that the physiological conditions of the oral cavity have an influence on the rheological properties of the denture adhesive cream. Specifically, our data indicates that the adhesive's mechanical properties are weakly influenced by pH, but do change with respect to the temperature in the oral cavity and the swelling rate of the adhesive. CONCLUSIONS: Our results suggest that the collective inter-play of the parameters pH, temperature and swelling ratio have an influence on the behavior of the denture adhesive. The results clearly highlight the need for developing a multi-parameter viscoelastic material model to understand the collective influence of physiological parameters on the performance of denture adhesives. Multi-parameter models can also potentially be utilized in numerically simulating denture adhesives using finite element simulations.


Subject(s)
Dental Cements , Denture Retention , Humans , Dental Cements/chemistry , Temperature , Mouth , Hydrogen-Ion Concentration
9.
BMC Oral Health ; 24(1): 138, 2024 Jan 28.
Article in English | MEDLINE | ID: mdl-38281916

ABSTRACT

Different characteristics of bars (cross-sectional shape, diameter, distal extension etc.) lead to different biomechanical behavior (retention and stress) with implants and peri-implant tissues.Aim: To evaluate the impact of implant-supported removable prostheses bar designs in fully edentulous arch (in the maxilla and/or mandibula), with 4 implants or more, on the peri-implant soft and hard tissues.Two reviewers searched for observational studies, RCT and in vitro studies, published on five main databases and three from the grey literature, without restrictions on November 2023.Of the 3049 selected articles, four met the inclusion criteria. Four RCT evaluated peri-implant health tissues in full edentulous arches with 4 or 6 implants rehabilitated with implant bar overdentures. One prospective study with 5 years follow-up evaluated the success/survival rate of implants and implant bar overdentures. Overall, 261 subjects were enrolled in our systematic review with 1176 implants. Overdentures' survival rate was 100%. There was a trend that plaque indices and gingival indices were low in all of the studies, however no statistical analysis was done due to the lack of information.Due to the lack of information in the included studies, we cannot confirm if bar characteristics affect the peri-implant tissues health.


Subject(s)
Dental Implants , Jaw, Edentulous , Mouth, Edentulous , Humans , Prospective Studies , Dental Prosthesis, Implant-Supported , Mandible , Denture, Overlay , Denture Retention
10.
J Prosthodont ; 33(2): 164-170, 2024 Feb.
Article in English | MEDLINE | ID: mdl-36779671

ABSTRACT

PURPOSE: To investigate the retentive behavior of the Locator legacy and Novaloc attachment systems with different retention inserts both within and across systems under cyclic load. MATERIALS AND METHODS: Three retention inserts of each system (green, yellow, and white for Novaloc; green, orange, and red inserts for extended range for legacy Locator) were tested on abutments of both systems with a sample number of 10 per force and 10,000 cycles of insertion and removal. The loading was applied in the axial direction of the abutments, which were placed in artificial saliva. The retention force was measured in each cycle. The results were compared with the manufacturer's specifications and evaluated for a simulated period of use of 10 years. Characteristic time constants were determined, and subsequently, the two systems were compared regarding their wear behavior. RESULTS: The manufacturer's specifications could only be confirmed for the green Novaloc retention insert on a Novaloc abutment (t-test: p = 0.50); for all other inserts, the baseline exceeded the manufacturer's specifications by 30%-75% (Novaloc; t-test: p < 0.001) and 75%-550% (Locator; t-test: p < 0.001). After 10,000 cycles performed, the manufacturer's specifications were confirmed on a Novaloc abutment for the white Novaloc retention insert (t-test: p = 0.86) and on a Locator abutment for the green Novaloc retention insert (t-test: p = 0.32). Both systems lost retention force during the experiment. Overall, Novaloc inserts on both abutments showed less wear (decrease to 56%-85% of initial force) and a slower decrease in retention force compared to Locator inserts (decrease to 6%-31% of initial force). CONCLUSIONS: In both systems, wear leads to a varying loss of retention; therefore, regular checks with possible replacement of the inserts are necessary in clinical use. Novaloc attachments seem to be more resistant to the loss of retention than Locator attachments. A cross-combination may be clinically useful in some cases.


Subject(s)
Dental Implants , Denture Retention , Denture Retention/methods , Denture, Overlay , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Saliva, Artificial
11.
Eur J Prosthodont Restor Dent ; 32(1): 20-27, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-37549130

ABSTRACT

PURPOSE: The aim of this study was to evaluate the surface wear and retention force of telescopic attachments made of zirconia primary crowns and poly-ether- ketone -ketone (PEKK) secondary crowns for 2-implant retained mandibular complete overdentures. MATERIALS AND METHODS: Ten healthy completely edentulous patients aged 55-60 years were selected for this study. Each patient received two implants in the mandibular canine regions. Maxillary conventional complete dentures were constructed against implant-retained mandibular overdentures for all patients. Zirconia- PEKK telescopic attachments were fabricated to retain the overdentures where primary copings were constructed of zirconia and secondary ones were constructed of PEKK. Retention force and surface wear were evaluated at the time of overdenture insertion (T0), and after 6 months of overdenture use (T6). RESULTS: The results revealed less wear of zirconia copings compared to PEKK ones at T0 and T6. However, both materials showed insignificant wear after 6 months of overdenture use. A significant increase in retention force was observed after 6 months of overdenture use. CONCLUSION: Within limitations of this study, PEKK may be considered a promising alternative material for telescopic secondary crowns construction combined to zirconia primary ones, regarding the wear resistance and the satisfactory retention forces.


Subject(s)
Dental Implants , Zirconium , Humans , Ether , Ketones , Denture Retention , Ethyl Ethers , Ethers , Crowns , Denture, Overlay , Dental Prosthesis, Implant-Supported
12.
Spec Care Dentist ; 44(1): 124-129, 2024.
Article in English | MEDLINE | ID: mdl-37013961

ABSTRACT

OBJECTIVE: To present clinical strategies for prosthetic rehabilitation with complete dentures (CDs) of a Parkinson's disease patient. CASE REPORT: An 82-year-old patient sought the Department of Dentistry at UFRN, reporting retention dissatisfaction and hamper to the mandibular CD adaptation. Patient-reported a dry mouth sensation, and exhibited disordered mandibular movements, tremors, and resorbed mandibular ridge. Aiming retention and stability, double molding with zinc enolic oxide impression paste, neutral zone technique, and non-anatomic teeth were proposed as clinical strategies. At delivery, identification and relief in the supercompression areas were performed to facilitate the acceptance and use of the new dentures. CONCLUSION: The strategies promoted patient satisfaction regarding retention, stability, and comfort. This treatment may be considered for the rehabilitation of Parkinson's disease patients, favoring the adaptation process.


Subject(s)
Parkinson Disease , Humans , Aged, 80 and over , Parkinson Disease/complications , Denture Design/methods , Denture Retention/methods , Denture, Complete , Patient Satisfaction
13.
J Mech Behav Biomed Mater ; 150: 106269, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38043259

ABSTRACT

BACKGROUND: The stud-shaped attachment systems (AS) with different shape designs (ball, cylindrical, conical) and materials (metallic, plastic, or a combination of both) are commonly used to provide better retention and stability in implant-retained mandibular overdentures (IRMO). PURPOSE: The purpose of the present study was to evaluate and compare the retention loss and the wear (patterns, location, material loss) of three resilient unsplinted AS: a well-established ball attachment system (BAS) and two more recent cylindrical attachment systems (CAS), Locator R-Tx® and Novaloc®. MATERIALS AND METHODS: The implants, their corresponding abutments, the color-coded or position-coded retention devices (RD), the matrix metal housing were incorporated within CAD/CAM resin blocks and cyclically loaded with 19.6 N along the implant axis in a chewing machine to simulate 10,000 insertion-removal cycles (IRC). At cycle 10, 100, 1,000, 5,000, and 10,000, the retention force was measured using a universal testing machine. The wear was qualitatively examined using a binocular magnifier for both systems, and quantitatively assessed from micro-computed tomography acquisitions for CAS. Material loss exceeding 50 µm was considered significant. RESULTS: The three AS showed different retentive behavior along time. All the Locator R-Tx® RD lost more than 50 % of their retention after 10,000 IRC. The retention of the Ball System slightly varied over time, the final retention loss in Bmed and Bmax groups being lower than 25 % of the initial retention. Wear was located at the tip of their gold RD and at the equator area of their ball abutment. For Locator R-Tx®, the more retentive the plastic RD, the greater its wear and retention loss. Only Novaloc® maintained a stable retention with even a slight tendency to increase and showed a negligible wear. Implant abutments of the CAS showed no significant wear. CONCLUSION: After 10,000 IRC, corresponding to approximately 5-years clinical use, almost all RD provided retention force over 5 N, which could be sufficient to maintain satisfaction in most of the patients. The retention loss observed most prominently for the Locator R-Tx®, then for the Ball System, seemed to correlate with the wear observed on their RD. The practitioner may expect less RD maintenance with the Novaloc® stable retention overtime.


Subject(s)
Dental Implants , Denture, Overlay , Humans , Denture Retention/methods , X-Ray Microtomography , Mandible , Dental Stress Analysis
14.
J Prosthet Dent ; 131(2): 291.e1-291.e9, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38057199

ABSTRACT

STATEMENT OF PROBLEM: The retentive force and deformation of milled polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) removable partial denture (RPD) frameworks are not well understood. PURPOSE: The purpose of this in vitro study was to assess the retentive force and deformation of PEEK and PEKK Akers clasps with different designs and undercut depths. MATERIAL AND METHODS: A master model containing the first and second molar abutments was used to design Akers clasps of different cross-sectional dimensions, undercut depths (0.5 and 0.75 mm), and materials. The components of the removable partial denture framework also included an occlusal rest and were manufactured using a milling machine (n=5). The fatigue resistance of the Akers clasps was measured before and after deformation regarding the retentive forces. RESULTS: The PEEK2-U50 clasp had the largest retentive force with no significant difference among all groups before and after the insertion and removal cycle. In addition, the increased cross-sectional dimensions of the design resulted in significant differences in retentive forces between the PEEK1 and PEEK2 groups and between the PEEK and PEKK materials. CONCLUSIONS: Increasing the clasp's cross-sectional dimensions significantly impacted retentive forces, especially between different PEEK groups and between PEEK and PEKK materials.


Subject(s)
Benzophenones , Chromium Alloys , Denture, Partial, Removable , Polymers , Cross-Sectional Studies , Denture Retention , Polyethylene Glycols , Ketones , Dental Clasps
15.
Clin Implant Dent Relat Res ; 26(1): 103-112, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37926953

ABSTRACT

OBJECTIVES: This study aimed to evaluate the clinical outcomes and patient satisfaction of 4-implant-assisted maxillary overdentures using two different designs. MATERIALS AND METHODS: Thirty edentulous participants received four implants in the maxillary ridge. The patients were randomly divided into two equal groups: (1) the control (CG, Vertical) group (n = 15); participants received four vertical implants with straight locator attachments to retain maxillary overdentures, and (2) the study (SG, Angled) group (n = 15); participants received four angled implants with angled locator attachments to retain maxillary overdentures. Peri-implant tissue health [Plaque (PL) and gingival (GI) indices, pocket depth (PD), implant stability (ISQ) and crestal bone loss (CBL)] were evaluated after denture insertion (T0), 6 (T6), and 12 (T12) months after insertion. Patient satisfaction was evaluated using a visual analog scale (VAS) after 12 months. RESULTS: The survival rates were 96.7% and 95% for the control and study groups respectively. PL, GI, and PD increased significantly in both groups with the passage of time. No significant difference in PL, GI, PD, and ISQ was noted between groups at all observation times. CG showed higher CBL than SG at T12. For the VAS results, there was no significant difference between groups. SG recorded significantly higher satisfaction regarding comfort with maxillary and mandibular dentures, retention of mandibular dentures, oral hygiene, the ability to chew hard food, and occlusion than CG. CONCLUSION: Within the limitations of this study, angled implants with angled locator attachments may be recommended to retain maxillary overdentures opposing intact dentition or fixed restoration as it was associated with improvements of several parameters of peri-implant tissue health and patient satisfaction compared to vertical implants with straight locator attachments.


Subject(s)
Dental Implants , Dental Plaque , Jaw, Edentulous , Humans , Denture, Overlay , Denture Retention/methods , Patient Satisfaction , Mandible , Dental Prosthesis, Implant-Supported
16.
J Prosthodont ; 33(4): 324-329, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37805705

ABSTRACT

PURPOSE: To compare the effects of two denture adhesive formulations on the bite force required to dislodge a maxillary denture in adult participants during a 13-h test period. MATERIALS AND METHODS: Twenty-two participants with a fair-to-poor fitting maxillary denture opposed by natural dentition or a stable mandibular denture were enrolled in this single-center, randomized, double-blind, two-treatment, 4-period crossover study. Participants were randomly assigned a product usage sequence so that each participant used each product twice during the 4-day test period. The test product was a denture cream adhesive formulated with an optimized calcium/zinc partial salt of polyvinyl methyl ether/maleic acid (Fixodent Ultra technology); the control product was a cream adhesive formulated with a calcium/zinc partial salt of polyvinyl methyl ether/maleic acid (Fixodent Original technology). On each study day, bite force at dislodgement was measured with a gnathodynamometer at baseline, representing the "no adhesive" score. Then, after standardized product application to the participant's existing maxillary denture by site staff, bite force measurements were retaken at 1, 3, 5, 7, 9, 11, and 13 h. The change from baseline and the 13-h area under the bite-force-change-from-baseline curve were analyzed via an analysis of variance. RESULTS: Twenty-one participants completed all test periods; one additional participant completed three test periods so 22 participants were included in the analysis. There were 15 females and 7 males with a mean age of 70 years. The mean 13-h area under the bite-force-change-from-baseline curve was 8% greater (p = 0.010) for the test adhesive (114.3 lb) than for the control adhesive (105.9 lb). Both adhesives showed a statistically significant increase in bite force (p < 0.001) at each time point compared to no adhesive. CONCLUSIONS: The optimized calcium/zinc partial salt of polyvinyl methyl ether/maleic acid test adhesive provided superior maxillary denture retention relative to that of the control adhesive across 13 h. Both adhesives increased bite force at dislodgement compared to no adhesive.


Subject(s)
Dental Cements , Maleates , Methyl Ethers , Aged , Female , Humans , Male , Adhesives/therapeutic use , Calcium , Cross-Over Studies , Denture Retention , Denture, Complete , Polyvinyls , Zinc , Double-Blind Method
17.
J Prosthet Dent ; 131(2): 281.e1-281.e9, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37985307

ABSTRACT

STATEMENT OF PROBLEM: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with mandibular edentulism. However, information on the influence of implant positions on crestal strain is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the crestal strain around 2 implants to support mandibular overdentures when placed at different positions. MATERIAL AND METHODS: Edentulous mandibles were 3-dimensionally (3D) designed separately with 2 holes for implant placement at similar distances of 5, 10, 15, and 20 mm from the midline, resulting in 4 study conditions. The complete denture models were 3D designed and printed from digital imaging and communications in medicine (DICOM) images after scanning the patient's denture. Two 4.3×12-mm dummy implants were placed in the preplanned holes. Two linear strain gauges were attached on the crest of the mesial and distal side of each implant (CH1, CH2, CH3, and CH4) and connected to a computer to record the electrical signals. Male LOCATOR attachments were attached, the mucosal layer simulated, and the denture picked up with pink female nylon caps. A unilateral and bilateral force of 100 N was maintained for 10 seconds for each model in a universal testing machine while recording the maximum strains in the DCS-100A KYOWA computer software program. Data were analyzed by using 1-way analysis of variance, the Tukey post hoc test, and the paired t test (α=.05). RESULTS: Under bilateral loading, the strain values indicated a trend with increasing distance between the implants with both right and left distal strain gauges (CH4 and CH1). The negative (-ve) values indicated the compressive force, and the positive (+ve) values indicated the tensile force being applied on the strain gauges. The strain values for CH4 ranged between -166.08 for the 5-mm and -251.58 for the 20-mm position; and for CH1 between -168.08 for the 5-mm and -297.83 for the 20-mm position. The remaining 2 mesial strain gauges for all 4 implant positions remained lower than for CH4 and CH1. Under unilateral-right loading, only the right-side distal strain gauge CH4 indicated the increasing trend in the strain values with -147.5 for the 5-mm, -157.17 for the 10-mm, -209.33 for the 15-mm, and -234.75 for the 20 mm position. The remaining 3 strain gauges CH3, CH2, and CH1 ranged between -28.33 and -107.17. For each position for both implants, significantly higher (P<.05) strain values were observed on the distal strain gauge channels CH4 and CH1 than on the mesial channels CH3 and CH2 under bilateral loading and on the right side under unilateral loading. CONCLUSIONS: Peri-implant crestal strains in the 2IMO increased by increasing the distance of the implants from the midline. The stress values progressively increased from 5 to 10 mm to 15 to 20 mm from midline, represented as lateral incisor, canine, and premolar positions. The distal side of the implants exhibits higher strains than the mesial side of the implants.


Subject(s)
Dental Implants , Humans , Female , Male , Denture, Overlay , Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Mandible/surgery , Printing, Three-Dimensional , Denture Retention
18.
Clin Exp Dent Res ; 10(1): e813, 2024 02.
Article in English | MEDLINE | ID: mdl-38044541

ABSTRACT

OBJECTIVES: This study sought to determine the impact of age, gender, and use of maxillary implant-supported overdenture (UISOD) versus conventional denture (CMD) opposing mandibular implant-supported overdenture (LISOD) and the number of years the patient has used their prosthesis on the ratings of satisfaction. This study aimed to assess the long-term influence of different factors on patients' satisfaction with LISODs needing a maxillary prosthesis, helping dentists choose a treatment pathway that leads to a higher satisfaction rate. MATERIAL AND METHODS: This cross-sectional study included 84 participants. They were treated with LISOD opposing either CMD or UISOD from 2015 to 2020. They were all eligible to participate in the study. An oral health impact profile (OHIP-14) questionnaire was given to each patient and filled out by them. OHIP-14 scores were gathered and went under statistical analysis with PASS-11 software to determine the relationship between patients' satisfaction with the scores. RESULTS: Age and gender had no significant influence on how satisfied patients were. Patients with maxillary overdentures showed more satisfaction than the CMD group (p < .05). Moreover, patients' satisfaction decreased with increasing years of prostheses usage (p < .05). CONCLUSIONS: This study demonstrated that satisfaction is related to the type of maxillary prosthesis (conventional or implant-supported) used opposing LISODs and the number of years the patient had used the prostheses.


Subject(s)
Dental Implants , Patient Satisfaction , Humans , Denture, Overlay , Cross-Sectional Studies , Denture Retention , Dental Prosthesis, Implant-Supported
19.
Dent Mater J ; 43(1): 90-96, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38148022

ABSTRACT

This study aimed to evaluate the thermocycling effect on the retentive force of 3 different retentive inserts in 3 denture attachments (Blue, Pink, Clear retentive inserts in LOCATOR; Blue, Pink, Clear retentive inserts in LOCATOR R-Tx; and White, Yellow, Green retentive inserts in Novaloc) (n=10). Maximum retentive force of each retentive insert was evaluated at baseline, 7-day water storage, and after 5,000-, and 10,000- cycle thermocycling. The water absorption percentage of the retentive inserts was also determined. Comparing between baseline and 7-day water storage, the retentive forces of the LOCATOR and LOCATOR R-Tx groups were significantly reduced (p<0.05), while the retentive force of the Novaloc group was significantly increased (p<0.05). Comparing between 7-day water storage and 10,000-cycle thermocycling, the retentive force of most retentive inserts remained unchanged (p>0.05). The water absorption percentage of the LOCATOR and LOCATOR R-Tx groups was significantly greater than that of the Novaloc group (p<0.05).


Subject(s)
Denture Retention , Water , Denture, Overlay , Dental Stress Analysis , Dental Prosthesis, Implant-Supported
20.
BMC Oral Health ; 23(1): 982, 2023 12 08.
Article in English | MEDLINE | ID: mdl-38066586

ABSTRACT

BACKGROUND: The aim of this study was to compare the microstrain transmitted to peri-implant tissues of implant-assisted mandibular overdentures using two different low-profile attachment designs; OT- Equator attachment with and without bar attachment. MATERIALS AND METHODS: A completely edentulous epoxy resin mandibular model was used, in which two parallel dental implants were inserted at the canine region bilaterally and one in the middle. Sixteen identical complete edentulous mandibular overdentures were fabricated following conventional, standardized techniques and were divided equally between two groups according to the design and placement of the OT-Equator. Group A implants were kept solitary with an OT-Equator attachment, while group B implants were kept splinted with a bar associated with two mini-OT-Equator attachments in between. Sixteen identical mandibular complete overdentures were constructed, to which attachments were picked up. The difference in stress distribution was measured using strain gauges and compared between the two studied groups. A vertical load of 100 N using the universal testing machine was applied unilaterally on the left mesial fossae of the mandibular first molar and bilaterally on the bar attached to the mandibular premolar molar region of the overdentures. Statistical analysis was conducted using IBM SPSS version 28. Normality was checked by using the Shapiro-Wilk test and normality plots. The Mann-Whitney U test was then used to analogize the groups. RESULTS: There was a statistically significant difference between groups A and B upon application of vertical unilateral and bilateral loadings of 100 N, with mean microstrain values of P 0.05. Group A (OT-Equator attachment) showed lower strain values than Group B (OT-Equator bar attachment) upon application of vertical, unilateral, and bilateral loadings of 100 N. CONCLUSIONS: Implant-assisted mandibular overdenture with a solitary attachment is associated with lower microstrain values around the implants after application of unilateral and bilateral vertical loadings of 100 N.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Denture, Overlay , Dental Prosthesis, Implant-Supported , Mandible , Denture Retention , Dental Stress Analysis/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...