Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.005
Filter
1.
J Cardiothorac Surg ; 19(1): 306, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822410

ABSTRACT

Peripheral venous catheter fracture with cardiovascular embolization is a rare but potentially serious complication. Herein, we report a case of peripheral venous catheter fracture with embolization in right ventricle in a preterm infant. The catheter fragment was successfully removed by surgical procedure via median sternotomy under cardiopulmonary bypass(CPB).We hope this case will increase awareness of this rare complication and improve cannulation safety.


Subject(s)
Catheterization, Peripheral , Device Removal , Infant, Premature , Humans , Infant, Newborn , Catheterization, Peripheral/methods , Device Removal/methods , Male , Equipment Failure , Heart Ventricles/surgery , Female
2.
Sci Rep ; 14(1): 10192, 2024 05 03.
Article in English | MEDLINE | ID: mdl-38702341

ABSTRACT

Inferior vena cava (IVC) filters are considered when patients with venous thromboembolism (VTE) develop a contraindication to anticoagulation. Use of IVC filters is increasing, despite associated complications and lack of data on efficacy in reducing VTE-related mortality. We characterized the pattern of IVC filter use at a large community hospital between 2018 and 2022. Specifically, we assessed the indications for IVC filter insertion, filter removal rates, and filter-associated complications. Indications for IVC filters were compared to those outlined by current clinical practice guidelines. We reviewed 120 consecutive filter placement events. The most common indications included recent VTE and active bleeding (40.0%) or need for anticoagulation interruption for surgery (25.8%). Approximately one-third (30.0%) of IVC filters were inserted for indications either not supported or addressed by guidelines. Half (50.0%) of patients had successful removal of their IVC filter. At least 13 patients (10.8%) experienced a filter-related complication. In a large community-based practice, nearly one-third of IVC filters were inserted for indications not universally supported by current practice guidelines. Moreover, most IVC filters were not removed, raising the risk of filter-associated complications, and supporting the need for development of comprehensive guidelines addressing use of IVC filters, and post-insertion monitoring practices.


Subject(s)
Hospitals, Community , Vena Cava Filters , Venous Thromboembolism , Humans , Retrospective Studies , Female , Male , Middle Aged , Venous Thromboembolism/prevention & control , Aged , Anticoagulants/therapeutic use , Adult , Device Removal/methods
4.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38743522

ABSTRACT

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Device Removal , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve/pathology , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Device Removal/methods , Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation
6.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749633

ABSTRACT

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Device Removal/methods , Defibrillators, Implantable/adverse effects , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/diagnostic imaging , Pacemaker, Artificial/adverse effects , Male , Echocardiography, Transesophageal , Tomography, X-Ray Computed , Aged , Foramen Ovale, Patent/surgery , Foramen Ovale, Patent/diagnostic imaging , Female , Middle Aged
7.
BMJ Case Rep ; 17(5)2024 May 28.
Article in English | MEDLINE | ID: mdl-38806399

ABSTRACT

Increasing use of tracheal expandable metallic hybrid stents will lead to common encounters with these devices in emergency airway management. The presence of these stents qualifies any patient as a challenge when an emergency tracheostomy is needed. We report an unorthodox technique of tracheostomy with concomitant removal of tracheal stent, without any major complications. Although the combined approach with bronchoscopy and tracheostomy has been reported in similar cases, we present a safe procedure when rigid bronchoscopy is not available.


Subject(s)
Bronchoscopy , Device Removal , Tracheostomy , Humans , Tracheostomy/adverse effects , Tracheostomy/instrumentation , Tracheostomy/methods , Device Removal/methods , Bronchoscopy/methods , Stents/adverse effects , Trachea/surgery , Male , Tracheal Stenosis/surgery , Tracheal Stenosis/therapy , Tracheal Stenosis/etiology , Female
8.
J Orthop Surg Res ; 19(1): 290, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735949

ABSTRACT

BACKGROUND: As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws). METHODS: A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation. RESULTS: Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively. CONCLUSIONS: The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.


Subject(s)
Bone Screws , Femoral Neck Fractures , Finite Element Analysis , Fracture Fixation, Internal , Humans , Biomechanical Phenomena , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Femur Neck/surgery , Femur Neck/diagnostic imaging , Femur/surgery , Stress, Mechanical , Device Removal/methods
9.
Isr Med Assoc J ; 26(5): 273-277, 2024 May.
Article in English | MEDLINE | ID: mdl-38736340

ABSTRACT

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are increasingly being used; thus, there is an increasing need for transvenous lead extraction (TLE). OBJECTIVES: To summarize our experience with TLE at single referral center in northern Israel. METHODS: The study included all patients who underwent TLE at our center between 2019 and 2022, regardless of the indication. RESULTS: The cohort included 50 patients. The mean age was 69 ± 10.36 years; 78% were males. A total of 99 electrodes were targeted. The mean number of electrodes was 1.96 (range 1-4) per patient. The time between lead implantation and extraction ranged between 1.1 and 34 years with an average of 8.14 ± 5.71 years (median of 7.5 years). Complete lead removal was achieved in 98% of patients and in 98.99% of leads. The complete procedural success rate as well as the clinical procedural success rate was 96%. The procedural failure rate was 4% (1 patient died 2 days after the index procedure and 1 patient remained with large portion of lead). The indication for TLE was infection in 78% of the cohort group. Powered mechanical sheaths were used in 36 patients (72%), laser sheaths in 27 (54%), and a combination of laser and mechanical sheaths in 16 (32%). CONCLUSIONS: The clinical and procedural success rates of TLE, primarily for CEID-related infection, were high. A combination of laser and mechanical sheaths was needed in one-third of patients.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Humans , Device Removal/methods , Device Removal/statistics & numerical data , Male , Israel/epidemiology , Female , Aged , Retrospective Studies , Treatment Outcome , Middle Aged , Electrodes, Implanted , Aged, 80 and over
10.
BMC Womens Health ; 24(1): 301, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38769558

ABSTRACT

BACKGROUND: Successful efforts to encourage uptake of subdermal contraceptive implants, with a lifespan of three to five years, necessitate planning to ensure that quality removal services are available when desired. In Burkina Faso, implant use has tripled over the past 8 years and now comprises almost half of the contraceptive method mix. Population Monitoring for Action (PMA) surveys identified barriers to obtaining quality removal when desired, particularly when the implant is not palpable, or providers lack needed skills or supplies. The Expanding Family Planning Choices (EFPC) project supported ministries of health in four countries with evaluation and strengthening of implant removal services. METHODS: An implant removal landscape assessment was conducted at 24 health facilities in three regions of Burkina Faso with high implant use that included provider observations of implant removal, interviews with providers and health facility managers, and facility readiness surveys. The project used landscape data to mobilize stakeholders through a series of participatory workshops to develop a collaborative roadmap and commit to actions supporting quality implant removals. RESULTS: Landscape findings revealed key gaps in provision of quality removal services, including high levels of provider confidence for implant insertion and removal (82% and 71%, respectively), low competence performing simple and difficult removals (19.2% and 11.1%, respectively), inadequate supplies and equipment (no facilities had all necessary materials for removal), lack of difficult removal management systems, and a lack of standard data collection tools for removal. Exposure to the data convinced stakeholders to focus on removals rather than expanding insertion services. While not all roadmap commitments were achieved, the process led to critical investments in quality implant removals. CONCLUSION: Landscape data revealed that facilities lack needed supplies and equipment, and providers lack skills needed to perform quality implant removals, limiting client reproductive choice. Disseminating this data enabled stakeholders to identify and commit to evidence-based priority actions. Stakeholders have since capitalized on program learnings and the roadmap, including following MOH guidance for implant removal supplies and health provider training. Our experience in Burkina Faso offers a replicable model of how data can direct collective action to improve quality of contraceptive implant removals.


Subject(s)
Device Removal , Burkina Faso , Humans , Female , Device Removal/methods , Drug Implants , Family Planning Services/methods , Stakeholder Participation , Contraceptive Agents, Female , Health Facilities/statistics & numerical data
11.
J Med Case Rep ; 18(1): 234, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698425

ABSTRACT

BACKGROUND: Nexplanon implants are a common hormonal contraceptive modality. Though rare, these devices can embolize into the injured wall of the basilic vein, through the right heart, and finally wedge itself into a pulmonary artery. With adherence to the arterial wall over time, it becomes less amenable to endovascular retrieval. Patients may present with symptoms mimicking a pulmonary embolism, or without any symptoms at all. In asymptomatic cases, endovascular retrieval and/or surgery is required when patients wish to begin having children prior to biological inactivity. The current literature showed as little as nine case reports detailing lung tissue removal in the aim of reversing a patient's implanted contraceptive device. CASE PRESENTATION: A 22-year-old asymptomatic active-duty Caucasian female presented for elective outpatient Nexplanon removal. The suspicion of possible implant migration arose when it was discovered to be non-palpable in her left arm. After plain film x-rays failed to localize the implant, a chest x-ray and follow-up Computed Tomography (CT) scan revealed that the Nexplanon had migrated to a distal branch of the left pulmonary artery. Due to the patient's strong desires to begin having children, the decision was made for removal. Initial endovascular retrieval failed due to Nexplanon encapsulation within the arterial wall. Ultimately, the patient underwent a left video-assisted thoracoscopic surgery (VATS) for exploration and left lower lobe basilar S7-9 segmentectomy, which successfully removed the Nexplanon. CONCLUSIONS: Implanted contraceptive devices can rarely result in migration to the pulmonary vasculature. These radiopaque devices are detectable on imaging studies if patients and clinicians are unable to palpate them. An endovascular approach should be considered first to spare lung tissue and avoid chest-wall incisions, but can be complicated by encapsulation and adherence to adjacent tissue. A VATS procedure with single-lung ventilation via a double-lumen endotracheal tube allows surgeons to safely operate on an immobilized lung while anesthesiologists facilitate single-lung ventilation. This patient's case details the uncommon phenomenon of Nexplanon migration, and the exceedingly rare treatment resolution of lung resection to remove an embolized device.


Subject(s)
Desogestrel , Device Removal , Foreign-Body Migration , Humans , Female , Device Removal/methods , Desogestrel/administration & dosage , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Young Adult , Contraceptive Agents, Female/administration & dosage , Drug Implants , Pulmonary Artery/surgery , Pulmonary Artery/diagnostic imaging , Tomography, X-Ray Computed , Pulmonary Embolism/etiology , Treatment Outcome , Pneumonectomy
12.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
13.
BMC Musculoskelet Disord ; 25(1): 353, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724941

ABSTRACT

BACKGROUND: External fixation is widely used in the treatment of traumatic fractures; however, orthopedic surgeons encounter challenges in deciding the optimal time for fixator removal. The axial load-share ratio (LS) of the fixator is a quantitative index to evaluate the stiffness of callus healing. This paper introduces an innovative method for measuring the LS and assesses the method's feasibility and efficacy. Based on a novel hexapod LS-measurement system, the proposed method is to improve the convenience and precision of measuring LS in vivo, hence facilitating the safe removal of external fixators. METHODS: A novel hexapod system is introduced, including its composition, theoretical model, and method for LS measurement. We conducted a retrospective study on 82 patients with tibial fractures treated by the Taylor Spatial Frame in our hospital from September 2018 to June 2020, of which 35 took LS measurements with our novel method (Group I), and 47 were with the traditional method (Group II). The external fixator was removed when the measurement outcome (LS < 10%) was consistent with the surgeon's diagnosis based on the clinical and radiological assessment (bone union achieved). RESULTS: No significant difference was found in the fracture healing time (mean 25.3 weeks vs. 24.9 weeks, P > 0.05), frame-wearing duration (mean 25.5 weeks vs. 25.8 weeks, P > 0.05), or LS measurement frequency (mean 1.1 times vs. 1.2 times, P > 0.05). The measurement system installation time in Group I was significantly shorter compared to Group II (mean 14.8 min vs. 81.3 min, P < 0.001). The LS value of the first measurement in Group I was lower than that of Group II (mean 5.1% vs. 6.9%, P = 0.011). In Group I, the refracture rate was 0, but in Group II it was 4.3% (2/47, P > 0.05). CONCLUSION: The novel hexapod LS-measurement system and involved method demonstrated enhanced convenience and precision in measuring the LS of the external fixator in vivo. The LS measurement indicates the callus stiffness of fracture healing, and is applicable to evaluate the safety of removing the fixator. Consequently, it is highly recommended for widespread adoption in clinical practice.


Subject(s)
Device Removal , External Fixators , Fracture Fixation , Fracture Healing , Tibial Fractures , Humans , Female , Tibial Fractures/surgery , Male , Retrospective Studies , Adult , Middle Aged , Fracture Fixation/instrumentation , Fracture Fixation/methods , Device Removal/methods , Weight-Bearing , Young Adult , Aged , Feasibility Studies , Equipment Design
14.
Card Electrophysiol Clin ; 16(2): 125-132, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749630

ABSTRACT

The population of patients with advanced heart failure continues to increase steadily as does the need for mechanical circulatory support. Combination therapy with left ventricular assist devices (LVADs) and cardiovascular implantable electronic devices (CIEDs) is unavoidable. CIED complications in patients with LVADs are common and often necessitate device system revision and transvenous lead extraction. Despite this, management recommendations are limited, and guidelines are lacking.


Subject(s)
Device Removal , Heart Failure , Heart-Assist Devices , Humans , Heart-Assist Devices/adverse effects , Device Removal/methods , Heart Failure/therapy , Heart Failure/surgery , Defibrillators, Implantable/adverse effects
18.
Injury ; 55(6): 111533, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38631082

ABSTRACT

Diaphyseal fractures of the tibia is a common injury with an incidence of 16.9/100,000 population. Surgical treatment with intramedullary interlocking nail is the treatment of choice in closed diaphyseal tibial injuries. Removal of the nail is required in non-union, infected implant, implant failure or during exchange nailing procedure. Implant removal surgery presents some unique challenges to the Orthopaedic surgeons like broken nails, broken screws and failure of the extraction devices to engage with the threads of the nail due to stripping of the threads in the proximal part of the nail. Various techniques have been described by different authors to extract a broken distal piece of the nail. There are only a few articles described for the removal of an intramedullary nail when there is failure of the proximal extraction device. The failure of the proximal extraction device occurs due to the use of ill-fitting extraction bolts, cross threading and the presence of a very tight nail leading to stripping of the proximal threads. We describe a simple and novel technique with the use of the Stainless-Steel wire along with the extraction bolt when there is a failure of proximal extraction device for the extraction of cannulated or solid intramedullary nails.


Subject(s)
Bone Nails , Device Removal , Fracture Fixation, Intramedullary , Tibial Fractures , Adult , Humans , Male , Middle Aged , Device Removal/methods , Equipment Failure , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Tibial Fractures/surgery , Treatment Outcome
20.
Abdom Radiol (NY) ; 49(5): 1646-1652, 2024 05.
Article in English | MEDLINE | ID: mdl-38592493

ABSTRACT

PURPOSE: To evaluate the efficacy and safety of a novel technique for removal of migrated esophageal stent (MES) under fluoroscopy. METHODS: From January 2009 to April 2023, 793 patients with a dysphagia score of 3-4 underwent esophageal stenting at our center, and 25 patients (mean age: 70.06 years old; male/female: 15/10) underwent stent removal using "loop method" under fluoroscopy. The primary outcomes were technical success and complications. The secondary outcomes were procedure time, radiation exposure, biochemical indicators [white blood cell (WBC), hemoglobin (Hb), platelet (PLT), albumin (ALB), alanine transaminase (ALT), total bilirubin (TB), urea nitrogen (UN) and C-reactive protein] of pre- and post-treatment at 2 weeks. RESULTS: Technical success was 100% without major complications. The mean procedure time was (39.44 ± 9.28) minutes, which showed no statistical significance between benign (n = 5) and malignant (n = 20) group [(42.40 ± 8.85) vs (38.71 ± 9.46) mins, p > 0.05]. The mean radiation exposure was (332.88 ± 261.47) mGy, which showed no statistical significance between benign and malignant group [(360.74 ± 231.43) vs (325.92 ± 273.54) mGy, p > 0.05]. Pre- and post-procedure Hb [(114.46 ± 11.96) vs. (117.57 ± 13.12) g/L] and ALB [(42.26 ± 3.39) vs. (44.12 ± 3.77) g/L] showed significant difference (p < 0.05), while WBC, PLT, CRP, and ALT showed no significance (p > 0.05). CONCLUSION: Fluoroscopy-guided "Loop method" for MES removal is an effective and safe alternative technique.


Subject(s)
Device Removal , Stents , Humans , Female , Fluoroscopy , Male , Aged , Device Removal/methods , Foreign-Body Migration/diagnostic imaging , Retrospective Studies , Middle Aged , Deglutition Disorders/etiology , Radiography, Interventional/methods , Aged, 80 and over
SELECTION OF CITATIONS
SEARCH DETAIL
...