Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.340
Filter
1.
J Environ Manage ; 362: 121302, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38824896

ABSTRACT

Two industrial solid wastes, Ti-bearing blast furnace slag (TBFS) and diamond wire saw silicon waste (DWSSW), contain large amounts of Ti and Si, and their accumulation wastes resources and intensifies environmental pollution. In the present study, DWSSW was used as the silicon source to reduce titanium oxide in TBFS by electromagnetic induction smelting, and meanwhile Na3AlF6 was added as a flux to improve the recycling of the wastes. Ti and Si of the two wastes were simultaneously recovered in the form of alloy. The effects of different addition amount of Na3AlF6 flux in the mixture of DWSSW and TBFS on chemical composition, viscosity, basicity and structure of slag were investigated. The dissolution behavior of SiO2 in Na3AlF6 flux was theoretically deduced and experimentally verification. The optimized recovery rate of Ti and Si were obtained, and the research realizes the efficient recycling of DWSSW and TBFS simultaneously.


Subject(s)
Alloys , Recycling , Silicon , Titanium , Titanium/chemistry , Silicon/chemistry , Alloys/chemistry , Diamond/chemistry , Industrial Waste/analysis
2.
J Hazard Mater ; 472: 134458, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38703679

ABSTRACT

Diclofenac (DCF) is an environmentally persistent, nonsteroidal anti-inflammatory drug (NSAID) with thyroid disrupting properties. Electrochemical advanced oxidation processes (eAOPs) can efficiently remove NSAIDs from wastewater. However, eAOPs can generate transformation products (TPs) with unknown chemical and biological characteristics. In this study, DCF was electrochemically degraded using a boron-doped diamond anode. Ultra-high performance liquid chromatography coupled with high-resolution mass spectrometry was used to analyze the TPs of DCF and elucidate its potential degradation pathways. The biological impact of DCF and its TPs was evaluated using the Xenopus Eleutheroembryo Thyroid Assay, employing a transgenic amphibian model to assess thyroid axis activity. As DCF degradation progressed, in vivo thyroid activity transitioned from anti-thyroid in non-treated samples to pro-thyroid in intermediately treated samples, implying the emergence of thyroid-active TPs with distinct modes of action compared to DCF. Molecular docking analysis revealed that certain TPs bind to the thyroid receptor, potentially triggering thyroid hormone-like responses. Moreover, acute toxicity occurred in intermediately degraded samples, indicating the generation of TPs exhibiting higher toxicity than DCF. Both acute toxicity and thyroid effects were mitigated with a prolonged degradation time. This study highlights the importance of integrating in vivo bioassays in the environmental risk assessment of novel degradation processes.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal , Diclofenac , Thyroid Gland , Water Pollutants, Chemical , Animals , Diclofenac/toxicity , Diclofenac/chemistry , Diclofenac/metabolism , Water Pollutants, Chemical/toxicity , Water Pollutants, Chemical/chemistry , Thyroid Gland/drug effects , Thyroid Gland/metabolism , Anti-Inflammatory Agents, Non-Steroidal/toxicity , Anti-Inflammatory Agents, Non-Steroidal/chemistry , Risk Assessment , Electrochemical Techniques , Molecular Docking Simulation , Endocrine Disruptors/toxicity , Endocrine Disruptors/chemistry , Endocrine Disruptors/metabolism , Xenopus laevis , Diamond/chemistry , Oxidation-Reduction , Boron/toxicity , Boron/chemistry
3.
Bioelectrochemistry ; 158: 108691, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38574451

ABSTRACT

We present a novel application of a nanocrystalline boron-doped diamond electrode (B-NCDE) for the construction of an electrochemical DNA biosensor based on double-stranded DNA (dsDNA) for various bioanalytical applications. Surface characterization of the transducer surface (prior and after the fabrication of negatively charged O-terminated surface - O-B-NCDE) was performed by scanning electron microscopy (SEM), Raman spectroscopy, and linear sweep voltammetry (LSV) that was further used for the voltammetric determination, scan rate dependence investigation, and repeatability examination of dsDNA electrochemical oxidation at the O-B-NCDE. The fabrication of a dsDNA/O-B-NCDE biosensor via electrostatic adsorption of dsDNA involved a thorough optimization process of deposition potential (Edep), deposition time (tdep), and optimal saturation concentration (cg(satur)) with optimal values of 0.3 V, 3 min, and 10 mg/mL. The bioanalytical applicability of the fabricated dsDNA/O-B-NCDE biosensor was verified by examining the nature of the interaction between dsDNA and five selected DNA intercalators - namely thioridazine hydrochloride (TR), trimipramine maleate (TRIM), levomepromazine maleate (LEV), imipramine hydrochloride (IMI), and prochlorperazine maleate (PER) - where intercalation was proven for all of the five tested compounds. Moreover, the proposed novel bioanalytical test offers the possibility to selectively distinguish between the phenothiazine representatives (TR, LEV, and PER) and representatives of tricyclic antidepressants group (TRIM and IMI).


Subject(s)
Biosensing Techniques , Boron , DNA , Diamond , Electrodes , Biosensing Techniques/methods , DNA/chemistry , DNA/analysis , Diamond/chemistry , Boron/chemistry , Electrochemical Techniques/methods , Nanoparticles/chemistry
4.
Bioelectrochemistry ; 158: 108713, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38688079

ABSTRACT

Boron doped diamond has been considered as a fouling-resistive electrode material for in vitro and in vivo detection of neurotransmitters. In this study, its performance in electrochemical detection of dopamine and serotonin in neuron cultivation media Neurobasal™ before and after cultivation of rat neurons was investigated. For differential pulse voltammetry the limits of detection in neat Neurobasal™ medium of 2 µM and 0.2 µM for dopamine and serotonin, respectively, were achieved on the polished surface, which is comparable with physiological values. On oxidized surface twofold higher values, but increased repeatabilities of the signals were obtained. However, in Neurobasal™ media with peptides-containing supplements necessary for cell cultivation, the voltammograms were notably worse shaped due to biofouling, especially in the medium isolated after neuron growth. In these complex media, the amperometric detection mode at +0.75 V (vs. Ag/AgCl) allowed to detect portion-wise additions of dopamine and serotonin (as low as 1-2 µM), mimicking neurotransmitter release from vesicles despite the lower sensitivity in comparison with neat NeurobasalTM. The results indicate substantial differences in detection on boron doped diamond electrode in the presence and absence of proteins, and the necessity of studies in real media for successful implementation to neuron-electrode interfaces.


Subject(s)
Biofouling , Boron , Culture Media , Diamond , Dopamine , Electrodes , Neurons , Serotonin , Serotonin/analysis , Dopamine/analysis , Boron/chemistry , Diamond/chemistry , Animals , Neurons/cytology , Neurons/metabolism , Rats , Biofouling/prevention & control , Culture Media/chemistry , Electrochemical Techniques/methods
5.
Sensors (Basel) ; 24(8)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38676026

ABSTRACT

This work presents a novel multielectrode array (MEA) to quantitatively assess the dose enhancement factor (DEF) produced in a medium by embedded nanoparticles. The MEA has 16 nanocrystalline diamond electrodes (in a cell-culture well), and a single-crystal diamond divided into four quadrants for X-ray dosimetry. DEF was assessed in water solutions with up to a 1000 µg/mL concentration of silver, platinum, and gold nanoparticles. The X-ray detectors showed a linear response to radiation dose (r2 ≥ 0.9999). Overall, platinum and gold nanoparticles produced a dose enhancement in the medium (maximum of 1.9 and 3.1, respectively), while silver nanoparticles produced a shielding effect (maximum of 37%), lowering the dose in the medium. This work shows that the novel MEA can be a useful tool in the quantitative assessment of radiation dose enhancement due to nanoparticles. Together with its suitability for cells' exocytosis studies, it proves to be a highly versatile device for several applications.


Subject(s)
Diamond , Electrodes , Gold , Metal Nanoparticles , Diamond/chemistry , Metal Nanoparticles/chemistry , Gold/chemistry , Silver/chemistry , Platinum/chemistry , Radiation Dosage , Humans , X-Rays , Nanoparticles/chemistry
6.
Environ Pollut ; 347: 123705, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38442825

ABSTRACT

The ongoing challenge of water pollution by contaminants of emerging concern calls for more effective wastewater treatment to prevent harmful side effects to the environment and human health. To this end, this study explored for the first time the implementation of single-crystal boron-doped diamond (BDD) anodes in electrochemical wastewater treatment, which stand out from the conventional polycrystalline BDD morphologies widely reported in the literature. The single-crystal BDD presented a pure diamond (sp3) content, whereas the three other investigated polycrystalline BDD electrodes displayed various properties in terms of boron doping, sp3/sp2 content, microstructure, and roughness. The effects of other process conditions, such as applied current density and anolyte concentration, were simultaneously investigated using carbamazepine (CBZ) as a representative target pollutant. The Taguchi method was applied to elucidate the optimal operating conditions that maximised either (i) the CBZ degradation rate constant (enhanced through hydroxyl radicals (•OH)) or (ii) the proportion of sulfate radicals (SO4•-) with respect to •OH. The results showed that the single-crystal BDD significantly promoted •OH formation but also that the interactions between boron doping, current density and anolyte concentration determined the underlying degradation mechanisms. Therefore, this study demonstrated that characterising the BDD material and understanding its interactions with other process operating conditions prior to degradation experiments is a crucial step to attain the optimisation of any wastewater treatment application.


Subject(s)
Water Pollutants, Chemical , Water Purification , Humans , Boron/chemistry , Oxidation-Reduction , Diamond/chemistry , Water Pollutants, Chemical/chemistry , Electrodes , Water Purification/methods
7.
Chemosphere ; 355: 141763, 2024 May.
Article in English | MEDLINE | ID: mdl-38522672

ABSTRACT

The fluoroquinolones ciprofloxacin, danofloxacin, enoxacin, levofloxacin and lomefloxacin, occur in water bodies worldwide and therefore pose a threat to the aquatic environment. Advanced purification procedures, such as electrochemical oxidation, may act as a remedy since they contribute to eliminating contaminants and prevent micropollutants from entering open water bodies. By electrochemical treatment in a micro-flow reactor equipped with a boron-doped diamond (BDD) electrode, the fluoroquinolones were efficiently degraded. A total of 15 new products were identified using high-performance high-resolution chromatography coupled with high-resolution multifragmentation mass spectrometry. The ecotoxicity of the emerging transformation products was estimated through in silico quantitative structure activity relationship analysis. Almost all transformation products were predicted less ecotoxic than the initial compounds. The fluoroquinolone degradation followed three major mechanisms depending on the voltage during the electrochemical oxidation. At approximately 1 V, the reactions started with the elimination of molecular hydrogen from the piperazine moiety. At approx. 1.25 V, methyl and methylene groups were eliminated. At 1.5 V, hydroxyl radicals, generated at the BDD electrode, led to substitution at the piperazine ring. This novel finding of the three reactions depending on voltage contributes to the mechanistic understanding of electrochemical oxidation as potential remedy against fluoroquinolones in the aquatic environment.


Subject(s)
Ciprofloxacin , Water Pollutants, Chemical , Ciprofloxacin/chemistry , Levofloxacin/analysis , Enoxacin/analysis , Diamond/chemistry , Fluoroquinolones/analysis , Piperazine , Oxidation-Reduction , Electrodes , Water , Water Pollutants, Chemical/analysis
8.
Environ Pollut ; 346: 123688, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38431247

ABSTRACT

One challenge of the citrus industry is the treatment and disposal of its effluents due to their high toxicity, substantial organic load, and consequent resistance to conventional biotechnological processes. This study introduces a novel approach, using electrochemical oxidation with a boron-doped diamond anode to efficiently remove organic compounds from biodegraded pulp wash (treated using the fungus Pleurotus sajor-caju.) The findings reveal that employing a current density of 20 mA cm-2 achieves notable results, including a 44.1% reduction in color, a 70.0% decrease in chemical oxygen demand, an 88.0% reduction in turbidity, and an impressive 99.7% removal of total organic carbon (TOC) after 6 h of electrolysis. The energy consumption was estimated at 2.93 kWh g-1 of removed TOC. This sequential biological-electrochemical procedure not only significantly reduced the mortality rate (85%) of Danio rerio embryos but also reduced the incidence of morphologically altered parameters. Regarding acute toxicity (LC50) of the residue, the process demonstrated a mortality reduction of 6.97% for D. rerio and a 40.88% lethality decrease for Lactuca sativa seeds. The substantial reduction in toxicity and organic load observed in this study highlights the potential applicability of combined biological and electrochemical treatments for real agroindustrial residues or their effluents.


Subject(s)
Diamond , Water Pollutants, Chemical , Diamond/chemistry , Water Pollutants, Chemical/analysis , Electrolysis/methods , Organic Chemicals , Electrodes , Oxidation-Reduction
9.
ACS Sens ; 9(4): 1785-1798, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38384144

ABSTRACT

Real-time sensing of dopamine is essential for understanding its physiological function and clarifying the pathophysiological mechanism of diseases caused by impaired dopamine systems. However, severe fouling from nonspecific protein adsorption, for a long time, limited conventional neural recording electrodes concerning recording stability. This study reported a high-antifouling nanocrystalline boron-doped diamond microsensor grown on a carbon fiber substrate. The antifouling properties of this diamond sensor were strongly related to the grain size (i.e., nanocrystalline and microcrystalline) and surface terminations (i.e., oxygen and hydrogen terminals). Experimental observations and molecular dynamics calculations demonstrated that the oxygen-terminated nanocrystalline boron-doped diamond microsensor exhibited enhanced antifouling characteristics against protein adsorption, which was attributed to the formation of a strong hydration layer as a physical and energetic barrier that prevents protein adsorption on the surface. This finally allowed for in vivo monitoring of dopamine in rat brains upon potassium chloride stimulation, thus presenting a potential solution for the design of next-generation antifouling neural recording sensors. Experimental observations and molecular dynamics calculations demonstrated that the oxygen-terminated nanocrystalline boron-doped diamond (O-NCBDD) microsensor exhibited ultrahydrophilic properties with a contact angle of 4.9°, which was prone to forming a strong hydration layer as a physical and energetic barrier to withstand the adsorption of proteins. The proposed O-NCBDD microsensor exhibited a high detection sensitivity of 5.14 µA µM-1 cm-2 and a low detection limit of 25.7 nM. This finally allowed for in vivo monitoring of dopamine with an average concentration of 1.3 µM in rat brains upon 2 µL of potassium chloride stimulation, thus presenting a potential solution for the design of next-generation antifouling neural recording sensors.


Subject(s)
Diamond , Dopamine , Dopamine/analysis , Dopamine/chemistry , Animals , Diamond/chemistry , Hydrophobic and Hydrophilic Interactions , Rats , Biofouling/prevention & control , Boron/chemistry , Neurotransmitter Agents/analysis , Biosensing Techniques/methods , Adsorption , Molecular Dynamics Simulation , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Male , Nanoparticles/chemistry
10.
Proc Jpn Acad Ser B Phys Biol Sci ; 100(3): 149-164, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38311394

ABSTRACT

Since the large-volume press with a double-stage multianvil system was created by the late Professor Naoto Kawai, this apparatus (Kawai-type multianvil apparatus or KMA) has been developed for higher-pressure generation, in situ X-ray and neutron observations, deformation experiments, measurements of physical properties, synthesis of high-pressure phases, etc., utilizing its large sample volume and capacity in stable and homogeneous high temperature generation compared to those of competitive diamond anvil cells. These advancements in KMA technology have been made primarily by Japanese scientists and engineers, which yielded a wealth of new experimental data on phase transitions, melting relations, and physical characteristics of minerals and rocks, leading to significant constraints on the structures, chemical compositions, and dynamics of the deep Earth. KMA technology has also been used for synthesis of novel functional materials such as nano-polycrystalline diamond and transparent nano-ceramics, opening a new research field of ultrahigh-pressure materials science.


Subject(s)
Diamond , Technology , Diamond/chemistry , Physical Phenomena
11.
Biosensors (Basel) ; 14(2)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38391994

ABSTRACT

Amperometry is arguably the most widely used technique for studying the exocytosis of biological amines. However, the scarcity of human tissues, particularly in the context of neurological diseases, poses a challenge for exocytosis research. Human platelets, which accumulate 90% of blood serotonin, release it through exocytosis. Nevertheless, single-cell amperometry with encapsulated carbon fibers is impractical due to the small size of platelets and the limited number of secretory granules on each platelet. The recent technological improvements in amperometric multi-electrode array (MEA) devices allow simultaneous recordings from several high-performance electrodes. In this paper, we present a comparison of three MEA boron-doped diamond (BDD) devices for studying serotonin exocytosis in human platelets: (i) the BDD-on-glass MEA, (ii) the BDD-on-silicon MEA, and (iii) the BDD on amorphous quartz MEA (BDD-on-quartz MEA). Transparent electrodes offer several advantages for observing living cells, and in the case of platelets, they control activation/aggregation. BDD-on-quartz offers the advantage over previous materials of combining excellent electrochemical properties with transparency for microscopic observation. These devices are opening exciting perspectives for clinical applications.


Subject(s)
Serotonin , Humans , Boron/chemistry , Diamond/chemistry , Electrodes , Exocytosis , Quartz
12.
Anal Sci ; 40(5): 853-861, 2024 May.
Article in English | MEDLINE | ID: mdl-38246930

ABSTRACT

To minimize background interference in electrochemical enzymatic biosensors employing electron mediators, it is essential for the electrochemical oxidation of electroactive interfering species (ISs), such as ascorbic acid (AA), to proceed slowly, and for the redox reactions between electron mediators and ISs to occur at a low rate. In this study, we introduce a novel combination of a working electrode and an electron mediator that effectively mitigates interference effects. Compared to commonly used electrodes such as Au, glassy carbon, and indium tin oxide (ITO), boron-doped diamond (BDD) electrodes demonstrate significantly lower anodic current (i.e., lower background levels) in the presence of AA. Additionally, menadione (MD) exhibits notably slower reactivity with AA compared to other electron mediators such as Ru(NH3)63+, 4-amino-1-naphthol, and 1,4-naphthoquinone, primarily due to the lower formal potential of MD compared to AA. This synergistic combination of BDD electrode and MD is effectively applied in three biosensors: (i) glucose detection using electrochemical-enzymatic (EN) redox cycling, (ii) glucose detection using electrochemical-enzymatic-enzymatic (ENN) redox cycling, and (iii) lactate detection using ENN redox cycling. Our developed approach significantly outperforms the combination of ITO electrode and MD in minimizing IS interference. Glucose in artificial serum can be detected with detection limits of ~ 20 µM and ~ 3 µM in EN and ENN redox cycling, respectively. Furthermore, lactate in human serum can be detected with a detection limit of ~ 30 µM. This study demonstrates sensitive glucose and lactate detection with minimal interference, eliminating the need for (bio)chemical agents to remove interfering species.


Subject(s)
Boron , Diamond , Electrochemical Techniques , Electrodes , Glucose , Lactic Acid , Vitamin K 3 , Diamond/chemistry , Vitamin K 3/chemistry , Boron/chemistry , Glucose/analysis , Glucose/chemistry , Lactic Acid/analysis , Lactic Acid/chemistry , Biosensing Techniques , Electrons , Humans , Oxidation-Reduction
13.
ACS Appl Mater Interfaces ; 16(4): 4361-4374, 2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38232177

ABSTRACT

This study demonstrates the control of neuronal survival and development using nitrogen-doped ultrananocrystalline diamond (N-UNCD). We highlight the role of N-UNCD in regulating neuronal activity via near-infrared illumination, demonstrating the generation of stable photocurrents that enhance neuronal survival and neurite outgrowth and foster a more active, synchronized neuronal network. Whole transcriptome RNA sequencing reveals that diamond substrates improve cellular-substrate interaction by upregulating extracellular matrix and gap junction-related genes. Our findings underscore the potential of conductive diamond as a robust and biocompatible platform for noninvasive and effective neural tissue engineering.


Subject(s)
Diamond , Tissue Engineering , Diamond/pharmacology , Diamond/chemistry , Electric Conductivity , Neurons/physiology , Cell Survival
14.
Med Phys ; 51(1): 533-544, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37656015

ABSTRACT

BACKGROUND: Ion beam therapy allows for a substantial sparing of normal tissues and higher biological efficacy. Synthetic single crystal diamond is a very good material to produce high-spatial-resolution and highly radiation hard detectors for both dosimetry and microdosimetry in ion beam therapy. PURPOSE: The aim of this work is the design, fabrication and test of an integrated waterproof detector based on synthetic single crystal diamond able to simultaneously perform dosimetric and microdosimetric characterization of clinical ion beams. METHODS: The active elements of the integrated diamond device, that is, dosimeter and microdosimeter, were both realized in a Schottky diode configuration featured by different area, thickness, and shape by means of photolithography technologies for the selective growth of intrinsic and boron-doped CVD diamond. The cross-section of the sensitive volume of the dosimetric element is 4 mm2 and 1 µm-thick, while the microdosimetric one has an active cross-sectional area of 100 × 100 µm2 and a thickness of about 6.2 µm. The dosimetric and microdosimetric performance of the developed device was assessed at different depths in a water phantom at the MedAustron ion beam therapy facility using a monoenergetic uniformly scanned carbon ion beam of 284.7 MeV/u and proton beam of 148.7 MeV. The particle flux in the region of the microdosimeter was 6·107  cm2 /s for both irradiation fields. At each depth, dose and dose distributions in lineal energy were measured simultaneously and the dose mean lineal energy values were then calculated. Monte Carlo simulations were also carried out by using the GATE-Geant4 code to evaluate the relative dose, dose averaged linear energy transfer (LETd ), and microdosimetric spectra at various depths in water for the radiation fields used, by considering the contribution from the secondary particles generated in the ion interaction processes as well. RESULTS: Dosimetric and microdosimetric quantities were measured by the developed prototype with relatively low noise (∼2 keV/µm). A good agreement between the measured and simulated dose profiles was found, with discrepancies in the peak to plateau ratio of about 3% and 4% for proton and carbon ion beams respectively, showing a negligible LET dependence of the dosimetric element of the device. The microdosimetric spectra were validated with Monte Carlo simulations and a good agreement between the spectra shapes and positions was found. Dose mean lineal energy values were found to be in close agreement with those reported in the literature for clinical ion beams, showing a sharp increase along the Bragg curve, being also consistent with the calculated LETd for all depths within the experimental error of 10%. CONCLUSIONS: The experimental indicate that the proposed device can allow enhanced dosimetry in particle therapy centers, where the absorbed dose measurement is implemented by the microdosimetric characterization of the radiation field, thus providing complementary results. In addition, the proposed device allows for the reduction of the experimental uncertainties associated with detector positioning and could facilitate the partial overcoming of some drawbacks related to the low sensitivity of diamond microdosimeters to low LET radiation.


Subject(s)
Diamond , Protons , Diamond/chemistry , Radiometry , Carbon/therapeutic use , Ions , Monte Carlo Method , Water
15.
Oper Dent ; 49(1): 91-97, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38057997

ABSTRACT

OBJECTIVE: The aim was to compare intrapulp temperature (IPT) changes when flat-fissure diamond burs and pear-shaped tungsten carbide burs were used to cut tooth structure, amalgam, and composite resin with and without water coolant. METHODS: Thermocouples were inserted into the pulp chamber of extracted intact mandibular molars. The thermocouples were connected to an electronic thermometer that detects temperature every second to an accuracy of 0.1°C. IPT changes were recorded while using a high-speed handpiece during MOD cavity preparations (n=40), composite resin removal (n=40), and amalgam removal (n=40). A two-way ANOVA was used for each procedure to test for the effect of bur (pear-shaped tungsten carbide vs flat-fissured diamond) and water coolant (on vs off), with significant main effects (α=0.05) further analyzed using Tukey's multiple comparison test. RESULTS: During MOD cavity preparation, water coolant reduced changes in IPT (0.03±0.27°C) compared to no water coolant (1.27±0.29°C) when tungsten carbide burs were used (p<0.05) but not when diamond burs were used. During composite resin removal, tungsten carbide burs had less changes in IPT (0.55±0.18°C) compared to diamond burs (1.66±0.50°C) with no water coolant (p<0.05). Water coolant also reduced changes in IPT (0.09±0.14°C) compared to no water coolant (1.66±0.50°C) when diamond burs were used (p<0.01). Water coolant did not significantly affect IPT when tungsten carbide burs were used. During amalgam removal, tungsten carbide burs had lower changes in IPT (0.56±0.15°C) compared to diamond burs (1.88±0.43°C) with no water coolant (p<0.05). Water coolant also significantly reduced changes in IPT (0.71±0.2°C) compared to no water coolant (1.88±0.43°C) when diamond burs were used (p<0.05) but not when tungsten carbide burs were used. CONCLUSIONS: Water coolant reduced IPT changes when drilling tooth structure with tungsten carbide burs, but not when removing amalgam or composite. Conversely, water coolant reduced IPT changes when drilling with flat fissure diamond burs to remove amalgam and composite, but not when removing tooth structure. When amalgam and composite were removed without water coolant, the tungsten carbide burs resulted in lower IPT changes than when flat fissure diamond burs were used in the same way.


Subject(s)
Tungsten Compounds , Water , Temperature , Water/chemistry , Dental High-Speed Equipment , Composite Resins/therapeutic use , Composite Resins/chemistry , Tungsten Compounds/chemistry , Diamond/chemistry , Surface Properties
16.
Med Phys ; 51(2): 1450-1459, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37742343

ABSTRACT

BACKGROUND: The possible emergence of the FLASH effect-the sparing of normal tissue while maintaining tumor control-after irradiations at dose-rates exceeding several tens of Gy per second, has recently spurred a surge of studies attempting to characterize and rationalize the phenomenon. Investigating and reporting the dose and instantaneous dose-rate of ultra-high dose-rate (UHDR) particle radiotherapy beams is crucial for understanding and assessing the FLASH effect, towards pre-clinical application and quality assurance programs. PURPOSE: The purpose of the present work is to investigate a novel diamond-based detector system for dose and instantaneous dose-rate measurements in UHDR particle beams. METHODS: Two types of diamond detectors, a microDiamond (PTW 60019) and a diamond detector prototype specifically designed for operation in UHDR beams (flashDiamond), and two different readout electronic chains, were investigated for absorbed dose and instantaneous dose-rate measurements. The detectors were irradiated with a helium beam of 145.7 MeV/u under conventional and UHDR delivery. Dose-rate delivery records by the monitoring ionization chamber and diamond detectors were studied for single spot irradiations. Dose linearity at 5 cm depth and in-depth dose response from 2 to 16 cm were investigated for both measurement chains and both detectors in a water tank. Measurements with cylindrical and plane-parallel ionization chambers as well as Monte-Carlo simulations were performed for comparisons. RESULTS: Diamond detectors allowed for recording the temporal structure of the beam, in good agreement with the one obtained by the monitoring ionization chamber. A better time resolution of the order of few µs was observed as compared to the approximately 50 µs of the monitoring ionization chamber. Both diamonds detectors show an excellent linearity response in both delivery modalities. Dose values derived by integrating the measured instantaneous dose-rates are in very good agreement with the ones obtained by the standard electrometer readings. Bragg peak curves confirmed the consistency of the charge measurements by the two systems. CONCLUSIONS: The proposed novel dosimetric system allows for a detailed investigation of the temporal evolution of UHDR beams. As a result, reliable and accurate determinations of dose and instantaneous dose-rate are possible, both required for a comprehensive characterization of UHDR beams and relevant for FLASH effect assessment in clinical treatments.


Subject(s)
Diamond , Helium , Diamond/chemistry , Helium/therapeutic use , Radiometry , Monte Carlo Method
17.
J Prosthet Dent ; 131(1): 164.e1-164.e11, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37945513

ABSTRACT

STATEMENT OF PROBLEM: High translucency zirconia (HTZ) has gained popularity as an esthetic computer-aided design and computer-aided manufacturing (CAD-CAM) material for monolithic restorations. A detailed comparison between different common surface and heat treatments with a non-treated HTZ control to explain the behavior of the material under stress is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of different surface and heat treatments on the surface roughness parameters (SRPs), topography, crystallography, and phase composition of HTZ used for monolithic restorations. MATERIAL AND METHODS: Ninety Ø11.9×1.18-mm HTZ disks (Prettau Anterior) were milled, sintered, and distributed into 9 groups (n=10); 8 experimental (coarse diamond grinding GC, fine diamond grinding GF, fine diamond grinding and 3-step polishing kit GF+P1, fine diamond grinding and 3-step polishing kit and diamond paste GF+P1+DP, fine diamond grinding and 2-step polishing kit GF+P2, fine diamond grinding and GF+Gl, fine diamond grinding and 3-step polishing and glazing GF+P1+Gl, airborne-particle abrasion with 50-µm alumina), and a control group (C, as-sintered). SRPs (AveSa, AveSv, AveSz) and 3-dimensional (3D) images were obtained using a noncontact 3D-optic-profilometer. The crystal structure was determined with scanning electron microscopy. Phase composition was analyzed by X-ray diffraction (XRD). Surface roughness parameters data were statistically analyzed by 1-way ANOVA and the Tukey HSD test (α=.05). RESULTS: The applied surface and heat treatment resulted in significantly different SRP mean values (P<.001) with different topographies. GC had the highest AveSa, AveSv, and AveSz mean values (0.95, 8.8, 17.4 µm, respectively) with significant microcracks. GF had significantly lower SRP with finer microcracks. GF+P1 had a significantly smoother surface, but GF+P2 resulted in SRP comparable with the GF group. GF+P1+DP had the smoothest homogenous surface (mean Sa: 0.08 µm). GF+P1 and GF+GL were equally effective, while GF+P1+GL was not superior. Airborne-particle abrasion produced a low Sa mean value (0.11 µm) with relatively high Sv and Sz mean values (5.9, 9.2 µm, respectively) and microcracks. A monoclinic phase was detected in all groups. All experimental groups had broadened XRD-peaks with lower intensity, suggesting the presence of the rhombohedral phase. CONCLUSIONS: The different surface and heat treatments altered the HTZ crystals and their surface roughness with distinct topographies. Cubic crystal changes take place under stress as shown by the scanning electron microscope and the XRD diffraction pattern and may transform to the rhombohedral phase.


Subject(s)
Dental Polishing , Hot Temperature , Materials Testing , Crystallography , Dental Polishing/methods , Surface Properties , Esthetics, Dental , Zirconium/chemistry , Microscopy, Electron, Scanning , Diamond/chemistry , Ceramics/chemistry
18.
Chemosphere ; 349: 140834, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38042421

ABSTRACT

Beauty salons (BS) are places that deal with a wide range of cosmetics with potentially hazardous chemicals, and their effluent should be properly treated before going to the sewage system, once it represents characteristics of industrial wastewater. This work provides an extensive characterization of a BS effluent and its respective electrochemical treatment by comparing NaCl, Na2SO4, and Na2S2O8 as supporting electrolytes with a boron-doped diamond (BDD) as anode, applying 10 or 30 mA cm-2 of current density (j). The inclusion of UVC irradiation was also performed but the improvements achieved in removing the organic matter were null or lower. The analysis of chemical oxygen demand (COD) removal, energy consumption, and total current efficiency (TCE) was required to prove the efficacy of the processes and the comparative study of the performance of different technologies. Precipitate analysis was also done due to the high turbidity of the raw effluent and the appearance of a precipitate before and during the electrolysis, mainly with Na2S2O8. The precipitate confirmed the presence of silicates and small amounts of heavy metals. The results clearly showed that 6 h of treatment with Na2SO4 achieved 58% of COD removal with an energy consumption of about 0.52 kWh m-3, being the best electrolyte option for treating BS effluent by applying 10 mA cm-2. Under these experimental conditions, the final wastewater can be directly discharged into the sewage system with a lower amount of visible precipitate, and with 73% less turbidity. The treatment here proposed can be used as an alternative to decision-makers and governments once it can be a step further in the implementation of better and advanced politics of water sanitation.


Subject(s)
Wastewater , Water Pollutants, Chemical , Oxidation-Reduction , Sewage , Sulfates/analysis , Water Pollutants, Chemical/analysis , Electrolytes , Diamond/chemistry , Electrodes
19.
Environ Sci Pollut Res Int ; 30(55): 117871-117880, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37875760

ABSTRACT

In this work, a new coating of boron-doped diamond ultra-nanocrystalline (U-NBDD), tailored to prevent massive formation of perchlorates during disinfection, is evaluated as electrode for the reclaiming of treated secondary wastewater by the electrochemically assisted disinfection process. Results obtained are compared to those obtained by using a standard electrode (STD) that was evaluated as a standard in previous research showing outstanding performance for this application. First tests were carried out to evaluate the chlorine speciation obtained after the electrolysis of synthetic chloride solutions at two different ranges of current densities. Concentrations of hypochlorite obtained using the U-NBDD anode at 25 mA cm-2 were 1.5-fold higher, outperforming STD anode; however, at 300 mA cm-2, an overturn on the behavior of anodes occurs where the amount of hypochlorite produced on STD anode was 1.5-fold higher. Importantly, at low current density the formation of chlorates and perchlorates is null using U-NBDD. Then, the disinfection of the real effluent of the secondary clarifier of a municipal wastewater treatment facility is assessed, where inactivation of Escherichia coli is achieved at low charge applied per volume electrolyzed (0.08 A h L-1) at 25 mA cm-2 using the U-NBDD. These findings demonstrate the appropriateness of the strategy followed in this work to obtain safer electro-disinfection technologies for the reclaiming of treated wastewater.


Subject(s)
Wastewater , Water Pollutants, Chemical , Diamond/chemistry , Disinfection/methods , Hypochlorous Acid , Perchlorates , Electrolysis/methods , Electrodes , Oxidation-Reduction , Water Pollutants, Chemical/chemistry
20.
Anal Chem ; 95(45): 16600-16608, 2023 11 14.
Article in English | MEDLINE | ID: mdl-37883708

ABSTRACT

Bacterial sensing based on quantum cascade laser spectroscopy coupled with diamond or gallium arsenide thin-film waveguides is a novel analytical tool for gaining high-resolution infrared spectroscopic information of planktonic and sessile bacteria, as shown in the present study for Escherichia coli. During observation periods of up to 24 h, diamond and gallium arsenide thin-film waveguide laser spectroscopy was compared to information obtained via conventional Fourier transform infrared spectroscopy. The proliferation behavior of E. coli at those surfaces was complementarily investigated using atomic force microscopy and scanning electron microscopy.


Subject(s)
Escherichia coli , Lasers , Spectroscopy, Fourier Transform Infrared , Diamond/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...