Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.536
Filter
1.
J Water Health ; 22(5): 905-922, 2024 May.
Article in English | MEDLINE | ID: mdl-38822469

ABSTRACT

This study addresses the heightened global reliance on point-of-use (PoU) systems driven by water quality concerns, ageing infrastructure, and urbanization. While widely used in Egypt, there is a lack of comprehensive evaluation of these systems. We assessed 10 reverse osmosis point-of-use systems, examining physicochemical, bacteriological, and protozoological aspects of tap water (inlets) and filtered water (outlets), adhering to standard methods for the examination of water and wastewater. Results showed significant reductions in total dissolved solids across most systems, with a decrease from 210 ± 23.6 mg/L in tap water to 21 ± 2.8 mg/L in filtered water for PoU-10. Ammonia nitrogen levels in tap water decreased from 0.05 ± 0.04 to 2.28 ± 1.47 mg/L to 0.02 ± 0.04 to 0.69 ± 0.64 mg/L in filtered water. Despite this, bacterial indicators showed no significant changes, with some systems even increasing coliform levels. Protozoological analysis identified prevalent Acanthamoeba (42.5%), less frequent Naegleria (2.5%), Vermamoeba vermiformis (5%), and potentially pathogenic Acanthamoeba genotypes. Elevated bacterial indicators in filtered water of point-of-use systems, combined with essential mineral removal, indicate non-compliance with water quality standards, posing a public health concern. Further research on the long-term health implications of these filtration systems is essential.


Subject(s)
Drinking Water , Osmosis , Water Purification , Egypt , Water Purification/methods , Drinking Water/microbiology , Drinking Water/parasitology , Water Quality , Water Microbiology , Filtration/instrumentation , Filtration/methods , Water Supply
2.
Mikrochim Acta ; 191(5): 293, 2024 05 01.
Article in English | MEDLINE | ID: mdl-38691169

ABSTRACT

To address the need for facile, rapid detection of pathogens in water supplies, a fluorescent sensing array platform based on antibiotic-stabilized metal nanoclusters was developed for the multiplex detection of pathogens. Using five common antibiotics, eight different nanoclusters (NCs) were synthesized including ampicillin stabilized copper NCs, cefepime stabilized gold and copper NCs, kanamycin stabilized gold and copper NCs, lysozyme stabilized gold NCs, and vancomycin stabilized gold/silver and copper NCs. Based on the different interaction of each NC with the bacteria strains, unique patterns were generated. Various machine learning algorithms were employed for pattern discernment, among which the artificial neural networks proved to have the highest performance, with an accuracy of 100%. The developed prediction model performed well on an independent test dataset and on real samples gathered from drinking water, tap water and the Anzali Lagoon water, with prediction accuracy of 96.88% and 95.14%, respectively. This work demonstrates how generic antibiotics can be implemented for NC synthesis and used as recognition elements for pathogen detection. Furthermore, it displays how merging machine learning techniques can elevate sensitivity of analytical devices.


Subject(s)
Anti-Bacterial Agents , Copper , Gold , Metal Nanoparticles , Silver , Metal Nanoparticles/chemistry , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/chemistry , Gold/chemistry , Copper/chemistry , Silver/chemistry , Drinking Water/microbiology , Drinking Water/analysis , Neural Networks, Computer , Spectrometry, Fluorescence/methods , Machine Learning , Bacteria/isolation & purification , Fluorescent Dyes/chemistry , Vancomycin/chemistry , Water Microbiology , Kanamycin/analysis
3.
Water Res ; 257: 121702, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38749337

ABSTRACT

While online monitoring of physicochemical parameters has widely been incorporated into drinking water treatment systems, online microbial monitoring has lagged behind, resulting in the use of surrogate parameters (disinfectant residual, applied dose, concentration × time, CT) to assess disinfection system performance. Online flow cytometry (online FCM) allows for automated quantification of total and intact microbial cells. This study sought to investigate the feasibility of online FCM for full-scale drinking water ozone disinfection system performance monitoring. A water treatment plant with high lime solids turbidity in the ozone contactor influent was selected to evaluate the online FCM in challenging conditions. Total and intact cell counts were monitored for 40 days and compared to surrogate parameters (ozone residual, ozone dose, and CT) and grab sample assay results for cellular adenosine triphosphate (cATP), heterotrophic plate counts (HPC), impedance flow cytometry, and 16S rRNA gene sequencing. Online FCM provided insight into the dynamics of the full-scale ozone system, including offering early warning of increased contactor effluent cell concentrations, which was not observed using surrogate measures. Positive correlations were observed between online FCM intact cell counts and cATP levels (Kendall's tau=0.40), HPC (Kendall's tau=0.20), and impedance flow cytometry results (Kendall's tau=0.30). Though a strong correlation between log intact cell removal and CT was not observed, 16S rRNA gene sequencing results showed that passage through the ozone contactor significantly changed the microbial community (p < 0.05). Potential causes of the low overall cell inactivation in the contactor and the significant changes in the microbial community after ozonation include regrowth in the later chambers of the contactor and varied ozone resistance of drinking water microorganisms. This study demonstrates the suitability of direct, online microbial analysis for monitoring full-scale disinfection systems.


Subject(s)
Disinfection , Drinking Water , Flow Cytometry , Ozone , Water Purification , Flow Cytometry/methods , Disinfection/methods , Drinking Water/microbiology , Water Purification/methods
4.
Environ Monit Assess ; 196(6): 547, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38743188

ABSTRACT

Foodborne illnesses caused by the consumption of contaminated foods have frequent occurrences in developing countries. The incorporation of contaminated water in food processes, preparation, and serving is directly linked to several gastrointestinal infections. Keeping in view, this study was conducted to assess the microbial quality of both drinking water sources and commonly consumed fresh ready-to-eat (RTE) foods in the region. The drinking water samples from water sources and consumer points, as well as food samples from canteens, cafes, hotels, and restaurants, were collected for the microbiological analysis. Fifty-five percent (n = 286) of water samples were found to be positive for total coliforms with MPN counts ranging from 3 to 2600 (100 ml) -1. E. coli was detected in nearly 30% of the total water samples. Overall, 65% tap water samples were found unsatisfactory, followed by submersible (53%), filter (40%), and WTP (30%) sources. Furthermore, the examination of RTE foods (n = 80) found that 60% were of unsatisfactory microbial quality with high aerobic plate counts. The salads were the most contaminated category with highest mean APC 8.3 log CFU/g followed by pani puri, chats, and chutneys. Presence of coliforms and common enteropathogens was observed in both water and food samples. The detected isolates from the samples were identified as Enterobacter spp., Klebsiella spp., Pseudomonas aeruginosa, Salmonella spp., Shigella spp., and Staphylococcus spp. Based on these findings, microbiological quality was found compromised and this may pose hazard to public health. This exploratory study in the Punjab region also suggests that poor microbiological quality of water sources can be an important source of contamination for fresh uncooked RTE foods, thus transferring pathogens to the food chain. Therefore, only safe potable drinking water post-treatment should be used at all stages.


Subject(s)
Drinking Water , Fast Foods , Food Microbiology , Water Microbiology , Drinking Water/microbiology , India , Fast Foods/microbiology , Bacteria/isolation & purification , Bacteria/classification , Food Contamination/analysis , Environmental Monitoring , Humans , Escherichia coli/isolation & purification
5.
PLoS One ; 19(5): e0299247, 2024.
Article in English | MEDLINE | ID: mdl-38781192

ABSTRACT

There is a rapid spread of antibiotic resistance in the environment. However, the impact of antibiotic resistance in drinking water is relatively underexplored. Thus, this study aimed to quantify antibiotic resistance genes (ARGs) and antibiotic residues in two drinking water production facilities (NW-E and NW-C) in North West Province, South Africa and link these parameters to bacterial communities. Physicochemical and ARG levels were determined using standard procedures. Residues (antibiotics and fluconazole) and ARGs were quantified using ultra-high performance liquid chromatography (UHPLC) chemical analysis and real-time PCR, respectively. Bacterial community compositions were determined by high-throughput 16S rRNA sequencing. Data were analysed using redundancy analysis and pairwise correlation. Although some physicochemical levels were higher in treated than in raw water, drinking water in NW-E and NW-C was safe for human consumption using the South African Water Quality Guideline (SAWQG). ARGs were detected in raw and treated water. In NW-E, the concentrations of ARGs (sul1, intl1, EBC, FOX, ACC and DHA) were higher in treated water than in raw water. Regarding antimicrobial agents, antibiotic and fluconazole concentrations were higher in raw than in treated water. However, in NW-C, trimethoprim concentrations were higher in raw than in treated water. Redundancy analysis showed that bacterial communities were not significantly correlated (Monte Carlo simulations, p-value >0.05) with environmental factors. However, pairwise correlation showed significant differences (p-value <0.05) for Armatimonas, CL500-29 marine group, Clade III, Dickeya and Zymomonas genera with environmental factors. The presence of ARGs and antibiotic residues in the current study indicated that antibiotic resistance is not only a clinical phenomenon but also in environmental settings, particularly in drinking water niches. Consumption of NW-E and NW-C treated water may facilitate the spread of antibiotic resistance among consumers. Thus, regulating and monitoring ARGs and antibiotic residues in drinking water production facilities should be regarded as paramount.


Subject(s)
Anti-Bacterial Agents , Drinking Water , Drinking Water/microbiology , Drinking Water/analysis , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/analysis , South Africa , Bacteria/genetics , Bacteria/drug effects , Drug Resistance, Microbial/genetics , Genes, Bacterial , RNA, Ribosomal, 16S/genetics , Water Microbiology , Humans , Fluconazole/pharmacology
6.
Sci Rep ; 14(1): 11346, 2024 05 18.
Article in English | MEDLINE | ID: mdl-38762566

ABSTRACT

Groundwater is the primary source of water for people living in rural areas, especially during seasons when surface water is contaminated or unavailable. In Colombia, people use groundwater as drinking water without additional treatment. In addition, there is no infrastructure for wastewater collection and sewage treatment in the region of the Middle Magdalena Valley. The current study aims to evaluate the quality of groundwater in this region to determine any potential health hazards associated with its consumption. To reach the objective, three (3) physicochemical and microbiological sampling campaigns were carried out during different hydrological periods. A total of 428 groundwater samples were analyzed for over 28 parameters. The results were compared with the water quality standards proposed by the US EPA and Colombian regulations for human consumption. The analysis revealed the presence of total and fecal coliforms in 89% and 58% of the analyzed samples, respectively, identifying them as the main contaminants in groundwater. Furthermore, the pH levels did not meet the standards set by the US EPA in 33.8% of the cases and by Colombian regulations in 31.02%. Additionally, 32.8%, 17.6%, 14.3%, and 10.9% of the samples failed to meet the established thresholds for apparent color, magnesium, iron, and nitrates, respectively, under both standards. Moreover, only the analyses of selenium, mercury, and zinc complied with the quality standards under both regulatory frameworks. Based on the Colombian Drinking-Water Quality Risk Index (CDWQRI-IRCA), the risk associated with water quality meant for human consumption was assessed. The results showed that over 84% of the samples analyzed posed a high risk to human health, 4.6% posed a medium risk, 5.5% posed a low risk, and only 5.7% posed no risk at all. Additionally, official mortality statistics for children under four years old were reviewed, which revealed two deaths in 2019 due to Acute Diarrheal Disease (ADD) caused by consumption of contaminated water. Therefore, it is crucial to implement water treatment systems, establish aqueducts in rural areas, and conduct rigorous and systematic monitoring of drinking water to ensure it is safe for human consumption. It is also important to track morbidity and mortality rates associated with water consumption.


Subject(s)
Drinking Water , Groundwater , Water Quality , Colombia , Groundwater/analysis , Humans , Drinking Water/analysis , Drinking Water/microbiology , Risk Assessment , Environmental Monitoring/methods , Water Pollutants, Chemical/analysis , Water Microbiology
8.
Chemosphere ; 359: 142338, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38754486

ABSTRACT

Harmful cyanobacteria in reservoirs pose a serious threat to drinking water safety due to the intracellular metabolites, such as toxins and unpleasant tastes & odours. Effective removal of harmful cyanobacteria with little to no cell damage is very important to ensure the safety of drinking water. This review first introduced development history of cyanobacterial removal technologies in drinking water treatment. Then, impacts of oxidation, coagulation and pre-oxidation enhanced coagulation processes on cyanobacterial removal and integrity of the cells were comprehensively evaluated and discussed. Oxidation can remove cyanobacteria, but high doses of oxidants can result in significant cell lysis and release of intracellular metabolites, especially when using chlorine or ozone. Although there is practically no cell damage during coagulation, the removal efficiency is low in many cases. Pre-oxidation may improve cyanobacterial removal by the subsequent solid-liquid separation processes, and moderate pre-oxidation with little to no cell lysis is very important. Mechanisms of interface interaction between pre-oxidants and cyanobacteria should be defined in future to ensure moderate pre-oxidation of algal cells. Fate of cyanobacterial cells in sludge is also reviewed because more and more waterworks return sludge supernatant to the inlet of plant. Damage to cyanobacterial cells in sludge depends mainly upon coagulant type and dosage, algal species, and cyanobacteria-containing sludge should be treated before cell lysis. Efficient techniques for harmless disposal of cyanobacteria-containing sludge should be developed in future. This paper will help to better understand the cyanobacterial removal processes and provide improved perspectives for future research in this field.


Subject(s)
Cyanobacteria , Drinking Water , Water Purification , Drinking Water/microbiology , Water Purification/methods , Oxidation-Reduction , Ozone , Sewage/microbiology
9.
Environ Sci Technol ; 58(22): 9500-9514, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38760010

ABSTRACT

Combined water, sanitation, and handwashing (WSH) interventions could reduce fecal contamination along more transmission pathways than single interventions alone. We measured Escherichia coli levels in 3909 drinking water samples, 2691 child hand rinses, and 2422 toy ball rinses collected from households enrolled in a 2-year cluster-randomized controlled trial evaluating single and combined WSH interventions. Water treatment with chlorine reduced E. coli in drinking water. A combined WSH intervention improved water quality by the same magnitude but did not affect E. coli levels on hands or toys. One potential explanation for the limited impact of the sanitation intervention (upgraded latrines) is failure to address dog and livestock fecal contamination. Small ruminant (goat or sheep) ownership was associated with increased E. coli levels in stored water and on child hands. Cattle and poultry ownership was protective against child stunting, and domesticated animal ownership was not associated with child diarrhea. Our findings do not support restricting household animal ownership to prevent child diarrheal disease or stunting but do support calls for WSH infrastructure that can more effectively reduce household fecal contamination.


Subject(s)
Family Characteristics , Feces , Feces/microbiology , Animals , Kenya , Humans , Escherichia coli , Rural Population , Drinking Water/microbiology , Sanitation , Hand Disinfection , Water Microbiology , Ownership , Diarrhea
10.
Anal Chem ; 96(22): 9270-9277, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38770656

ABSTRACT

Developing a specific, sensitive, rapid, and on-site method for detecting pathogenic bacteria in food samples is critical to ensuring public safety. This article demonstrates a CRISPR/Cas13a system and a chemiluminescence resonance energy transfer (CRET) (CRISPR/Cas 13a-assisted CRET)-based strategy for sensitive and on-site detection of pathogenic bacteria in real samples. Once the hybrid double strand of aptamerS. aureus-cRNA recognizes the target model bacteria of Staphylococcus aureus (S. aureus), the released cRNA would bind with CRISPR/Cas 13a to form a complex of cRNA-CRISPR/Cas 13a, which could cleave the RNA molecule in the detecting probe of horseradish peroxidase (HRP) modified-gold nanoparticles (AuNPs) linked by RNA (AuNPs-RNA-HRP), resulting in an enhanced chemiluminescence signal due to the CRET "OFF" phenomenon after introducing the chemiluminescence substrate of luminol. The CRISPR/Cas 13a-assisted CRET strategy successfully detected S. aureus in drinking water and milk with detection limits of 20 and 30 cfu/mL, respectively, within the recovery of 90.07-105.50%. Furthermore, after integrating with an immunochromatographic test strip (ICTS), the CRISPR/Cas 13a-assisted CRET strategy achieved the on-site detection of as low as 102 cfu/mL of S. aureus in drinking water and milk via a smartphone, which is about 10 times lower than that in the previously reported AuNPs-based colorimetric ICTS, demonstrating a convenient and sensitive detection method for S. aureus in real samples.


Subject(s)
CRISPR-Cas Systems , Gold , Milk , Staphylococcus aureus , Staphylococcus aureus/isolation & purification , Staphylococcus aureus/genetics , CRISPR-Cas Systems/genetics , Gold/chemistry , Milk/microbiology , Animals , Luminescent Measurements , Drinking Water/microbiology , Metal Nanoparticles/chemistry , Biosensing Techniques/methods , Limit of Detection , Luminescence
11.
Environ Geochem Health ; 46(6): 209, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38814487

ABSTRACT

A comprehensive understanding of water quality is essential for assessing the complex relationship between surface water and sources of pollution. Primarily, surface water pollution is linked to human and animal waste discharges. This study aimed to investigate the physico-chemical characteristics of drinking water under both dry and wet conditions, assess the extent of bacterial contamination in samples collected from various locations in District Shangla, and evaluate potential health risks associated with consuming contaminated water within local communities. For this purpose, 120 groundwater and surface water samples were randomly collected from various sources such as storage tanks, user sites, streams, ponds and rivers in the study area. The results revealed that in Bisham, lakes had the highest fecal coliform levels among seven tested sources, followed by protected wells, reservoirs, downstream sources, springs, rivers, and ditches; while in Alpuri, nearly 80% of samples from five sources contained fecal coliform bacteria. Similarly, it was observed that the turbidity level, total dissolved solids, electrical conductivity, biological oxygen demand, and dissolved oxygen in the surface drinking water sources of Bisham were significantly higher than those in the surface drinking water sources of Alpuri. Furthermore, the results showed that in the Alpuri region, 14% of the population suffers from dysentery, 27% from diarrhea, 22% from cholera, 13% from hepatitis A, and 16% and 8% from typhoid and kidney problems, respectively, while in the Bisham area, 24% of residents are affected by diarrhea, 17% by cholera and typhoid, 15% by hepatitis A, 14% by dysentery, and 13% by kidney problems. These findings underscore the urgent need for improved water quality management practices and public health interventions to mitigate the risks associated with contaminated drinking water. It is recommended to implement regular water quality monitoring programs, enhance sanitation infrastructure, and raise awareness among local communities about the importance of safe drinking water practices to safeguard public health.


Subject(s)
Drinking Water , Water Microbiology , Water Quality , Pakistan , Drinking Water/microbiology , Drinking Water/chemistry , Humans , Environmental Monitoring/methods , Groundwater/microbiology , Groundwater/chemistry , Feces/microbiology , Bacteria/isolation & purification
12.
Sci Total Environ ; 927: 172257, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38608912

ABSTRACT

Waterborne pathogens threaten 2.2 billion people lacking access to safely managed drinking water services, causing over a million annual diarrheal deaths. Individuals without access to chlorine reagents or filtration devices often resort to do-it-yourself (DIY) methods, such as boiling or solar disinfection (SODIS). However, these methods are not simple to implement. In this study, we introduced an innovative and easily implemented disinfection approach. We discovered that immersing aluminum foil in various alkaline solutions produces alkali-treated aluminum foil (ATA foil) that effectively adsorbs Escherichia coli (E. coli), Salmonella, and Acinetobacter through the generated surface aluminum hydroxide. For example, a 25 cm2 ATA foil efficiently captures all 104E. coli DH5α strains in 100 mL water within 30 min. Using a saturated suspension of magnesium hydroxide, a type of fertilizer, as the alkaline solution, the properties of the saturated suspension eliminate the need for measuring reagents or changing solutions, making it easy for anyone to create ATA foil. ATA foils can be conveniently produced within mesh bags and placed in household water containers, reducing the risk of recontamination. Replacing the ATA foil with a foil improves the adsorption efficiency, and re-immersing the used foil in the production suspension restores its adsorption capacity. Consequently, ATA foil is an accessible and user-friendly alternative DIY method for underserved communities. Verification experiments covering variations in the water quality and climate are crucial for validating the efficacy of the foil. Fortunately, the ATA foil, with DIY characteristics similar to those of boiling and SODIS, is well-suited for testing under diverse global conditions, offering a promising solution for addressing waterborne pathogens worldwide.


Subject(s)
Disinfection , Drinking Water , Water Purification , Drinking Water/microbiology , Drinking Water/chemistry , Disinfection/methods , Water Purification/methods , Water Microbiology , Water Supply
13.
Water Res ; 256: 121572, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38621316

ABSTRACT

The exploration of antibiotic resistance genes (ARGs) in drinking water reservoirs is an emerging field. Using a curated database, we enhanced the ARG detection and conducted a comprehensive analysis using 2.2 Tb of deep metagenomic sequencing data to determine the distribution of ARGs across 16 drinking water reservoirs and associated environments. Our findings reveal a greater diversity of ARGs in sediments than in water, underscoring the importance of extensive background surveys. Crucial ARG carriers-specifically Acinetobacter, Pseudomonas, and Mycobacterium were identified in drinking water reservoirs. Extensive analysis of the data uncovered a considerable concern for drinking water safety, particularly in regions reliant on river sources. Mobile genetic elements have been found to contribute markedly to the propagation of ARGs. The results of this research suggest that the establishment of drinking water reservoirs for supplying raw water may be an effective strategy for alleviating the spread of water-mediated ARGs.


Subject(s)
Drinking Water , Drug Resistance, Microbial , Metagenomics , Drinking Water/microbiology , Drug Resistance, Microbial/genetics , Water Microbiology , Drug Resistance, Bacterial/genetics , Water Supply
14.
J Water Health ; 22(4): 673-688, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38678421

ABSTRACT

This study assessed the bacteriological quality of raw, treated, and distributed water from Ede-Erinle and Opa reservoirs in Osun State, Nigeria. This was to determine the potability of water from these waterwork stations. Eighteen sampling points were established across the two reservoir networks for this study. Samples were collected bi-monthly for two annual cycles. Serial dilution and pour plate methods were employed for the enumeration of bacterial load. Total heterotrophic bacteria count (THBC) and total coliform bacteria count (TCBC) were enumerated on nutrient and MacConkey agar at 37 °C, respectively. Bacterial isolates were characterized using biochemical identification methods with reference to Bergey's Manual of Determinative Bacteriology. Bacterial isolates and biofilm formation were further identified molecularly through the PCR method using specific universal primers. Mean values of THBC and TCBC in distributed water from Ede-Erinle (9.61 × 104 ± 1.50 × 104 CFU/mL; 69.56 ± 26.81 CFU/mL) and Opa waterworks (9.58 × 104 ± 2.55 × 104 CFU/mL; 142.94 ± 44.41 CFU/mL) exceeded permissible limits for drinking water. Paenibacillus lautus, Bacillus pseudomycoides, Pseudomonas aeruginosa, and Pseudomonas stutzeri showed biofilm-forming capacity. The study concluded that the presence of coliforms and biofilm-forming bacteria in distributed water implies that the water is unfit for consumption without further treatment.


Subject(s)
Biofilms , Drinking Water , Enterobacteriaceae , Water Microbiology , Water Supply , Nigeria , Enterobacteriaceae/isolation & purification , Drinking Water/microbiology , Bacteria/isolation & purification , Bacteria/classification , Bacteria/genetics , Water Purification/methods
15.
Appl Environ Microbiol ; 90(5): e0004224, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38647288

ABSTRACT

Biofilms within drinking water distribution systems serve as a habitat for drinking water microorganisms. However, biofilms can negatively impact drinking water quality by causing water discoloration and deterioration and can be a reservoir for unwanted microorganisms. In this study, we investigated whether indicator organisms for drinking water quality, such as coliforms, can settle in mature drinking water biofilms. Therefore, a biofilm monitor consisting of glass rings was used to grow and sample drinking water biofilms. Two mature drinking water biofilms were characterized by flow cytometry, ATP measurements, confocal laser scanning microscopy, and 16S rRNA sequencing. Biofilms developed under treated chlorinated surface water supply exhibited lower cell densities in comparison with biofilms resulting from treated groundwater. Overall, the phenotypic as well as the genotypic characteristics were significantly different between both biofilms. In addition, the response of the biofilm microbiome and possible biofilm detachment after minor water quality changes were investigated. Limited changes in pH and free chlorine addition, to simulate operational changes that are relevant for practice, were evaluated. It was shown that both biofilms remained resilient. Finally, mature biofilms were prone to invasion of the coliform, Serratia fonticola. After spiking low concentrations (i.e., ±100 cells/100 mL) of the coliform to the corresponding bulk water samples, the coliforms were able to attach and get established within the mature biofilms. These outcomes emphasize the need for continued research on biofilm detachment and its implications for water contamination in distribution networks. IMPORTANCE: The revelation that even low concentrations of coliforms can infiltrate into mature drinking water biofilms highlights a potential public health concern. Nowadays, the measurement of coliform bacteria is used as an indicator for fecal contamination and to control the effectiveness of disinfection processes and the cleanliness and integrity of distribution systems. In Flanders (Belgium), 533 out of 18,840 measurements exceeded the established norm for the coliform indicator parameter in 2021; however, the source of microbial contamination is mostly unknown. Here, we showed that mature biofilms, are susceptible to invasion of Serratia fonticola. These findings emphasize the importance of understanding and managing biofilms in drinking water distribution systems, not only for their potential to influence water quality, but also for their role in harboring and potentially disseminating pathogens. Further research into biofilm detachment, long-term responses to operational changes, and pathogen persistence within biofilms is crucial to inform strategies for safeguarding drinking water quality.


Subject(s)
Biofilms , Drinking Water , Enterobacteriaceae , Biofilms/growth & development , Drinking Water/microbiology , Enterobacteriaceae/physiology , Enterobacteriaceae/isolation & purification , RNA, Ribosomal, 16S/genetics , Water Quality , Water Purification , Water Microbiology , Water Supply
16.
Poult Sci ; 103(5): 103601, 2024 May.
Article in English | MEDLINE | ID: mdl-38503136

ABSTRACT

This experiment investigated the influence of different synbiotic processing methods on the intestinal bacterial count, morphology and histological status of developed male Mandarah chicks. Two hundred and ten male Mandarah line chicks aged 1 d were randomized to receive one of 7 chicks. The method and dose for 1-time synbiotics administration to the day-old chicks were as follows: G1: chicks on basal diet received no treatment (control); G2: 0.25 mL synbiotics sprayed; G3: 0.50 mL synbiotics sprayed; G4: 0.25 mL of synbiotics are added to drinking water; G5: 0.50 mL of synbiotics are added to drinking water; G6: 0.25 mL of synbiotics dripped into the mouth; and G7: 0.50 mL of synbiotics dripped into mouth drops. Lactic acid bacteria(LAB) were significantly increased (P<0.0001) compared to the control group and other treated groups and had the maximum values after the use of synbiotics via drinking water (0.25 or 0.50 mL). Furthermore, when comparing the treated birds (G4, G5) with the control birds, the Escherichia coli concentration in the drinking water containing synbiotics was significantly lower. In addition, treated chickens at (G7) showed a higher duodenum, ileum villus height (VH), and VH. - Ileum crypt depth (CD) ratio compared to other groups. In addition, birds treated with 0.50 mL of synbiotics in drinking water (G5) performed better in duodenum, ileum, CD and VH. - CD ratio than the other groups. Meanwhile, intestinal tract length and visceral pH did not differ significantly between groups. It can be concluded that the use of 0.25 mL of synbiotics in drinking water can improve the overall health of birds.


Subject(s)
Chickens , Diet , Intestines , Synbiotics , Animals , Chickens/physiology , Male , Synbiotics/administration & dosage , Diet/veterinary , Intestines/anatomy & histology , Intestines/microbiology , Random Allocation , Animal Feed/analysis , Bacterial Load , Gastrointestinal Microbiome , Drinking Water/microbiology
17.
Talanta ; 274: 125962, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38537355

ABSTRACT

The importance of water in all biological processes is undeniable. Ensuring access to clean and safe drinking water is crucial for maintaining sustainable water resources. To elaborate, the consumption of water of inadequate quality can have a repercussion on human health. Furthermore, according to the instability of tap water quality, the consumption rate of bottled water is increasing every day at the global level. Although most people believe bottled water is safe, it can also be contaminated by microbiological or chemical pollution, which can increase the risk of disease. Over the last decades, several conventional analytical tools applied to analyze the contamination of bottled water. On the other hand, some limitations restrict their application in this field. Therefore, biosensors, as emerging analytical method, attract tremendous attention for detection both microbial and chemical contamination of bottled water. Biosensors enjoy several facilities including selectivity, affordability, and sensitivity. In this review, the developed biosensors for analyzing contamination of bottled water were highlighted, as along with working strategies, pros and cons of studies. Challenges and prospects were also examined.


Subject(s)
Biosensing Techniques , Drinking Water , Plastics , Drinking Water/microbiology , Drinking Water/analysis , Biosensing Techniques/methods , Plastics/chemistry , Water Pollutants, Chemical/analysis , Water Microbiology , Humans
18.
Sci Total Environ ; 927: 171301, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38423320

ABSTRACT

The occurrence of harmful algal blooms (HABs) in freshwater environments has been expanded worldwide with growing frequency and severity. HABs can pose a threat to public water supplies, raising concerns about safety of treated water. Many studies have provided valuable information about the impacts of HABs and management strategies on the early-stage treatment processes (e.g., pre-oxidation and coagulation/flocculation) in conventional drinking water treatment plants (DWTPs). However, the potential effect of HAB-impacted water in the granular media filtration has not been well studied. Biologically-active filters (BAFs), which are used in drinking water treatment and rely largely on bacterial community interactions, have not been examined during HABs in full-scale DWTPs. In this study, we assessed the bacterial community structure of BAFs, functional profiles, assembly processes, and bio-interactions in the community during both severe and mild HABs. Our findings indicate that bacterial diversity in BAFs significantly decreases during severe HABs due to the predominance of bloom-associated bacteria (e.g., Spingopyxis, Porphyrobacter, and Sphingomonas). The excitation-emission matrix combined with parallel factor analysis (EEM-PARAFAC) confirmed that filter influent affected by the severe HAB contained a higher portion of protein-like substances than filter influent samples during a mild bloom. In addition, BAF community functions showed increases in metabolisms associated with intracellular algal organic matter (AOM), such as lipids and amino acids, during severe HABs. Further ecological process and network analyses revealed that severe HAB, accompanied by the abundance of bloom-associated taxa and increased nutrient availability, led to not only strong stochastic processes in the assembly process, but also a bacterial community with lower complexity in BAFs. Overall, this study provides deeper insights into BAF bacterial community structure, function, and assembly in response to HABs.


Subject(s)
Drinking Water , Filtration , Harmful Algal Bloom , Water Purification , Water Purification/methods , Drinking Water/microbiology , Bacteria , Microbiota , Water Microbiology
19.
Environ Int ; 185: 108538, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38422875

ABSTRACT

Although simulated studies have provided valuable knowledge regarding the communities of planktonic bacteria and biofilms, the lack of systematic field studies have hampered the understanding of microbiology in real-world service lines and premise plumbing. In this study, the bacterial communities of water and biofilm were explored, with a special focus on the lifetime development of biofilm communities and their key influencing factors. The 16S rRNA gene sequencing results showed that both the planktonic bacteria and biofilm were dominated by Proteobacteria. Among the 15,084 observed amplicon sequence variants (ASVs), the 33 core ASVs covered 72.8 %, while the 12 shared core ASVs accounted for 62.2 % of the total sequences. Remarkably, it was found that the species richness and diversity of biofilm communities correlated with pipe age. The relative abundance of ASV2 (f_Sphingomonadaceae) was lower for pipe ages 40-50 years (7.9 %) than for pipe ages 10-20 years (59.3 %), while the relative abundance of ASV10 (f_Hyphomonadaceae) was higher for pipe ages 40-50 years (19.5 %) than its presence at pipe ages 20-30 years (1.9 %). The community of the premise plumbing biofilm had significantly higher species richness and diversity than that of the service line, while the steel-plastics composite pipe interior lined with polyethylene (S-PE) harbored significantly more diverse biofilm than the galvanized steel pipes (S-Zn). Interestingly, S-PE was enriched with ASV27 (g_Mycobacterium), while S-Zn pipes were enriched with ASV13 (g_Pseudomonas). Moreover, the network analysis showed that five rare ASVs, not core ASVs, were keystone members in biofilm communities, indicating the importance of rare members in the function and stability of biofilm communities. This manuscript provides novel insights into real-world service lines and premise plumbing microbiology, regarding lifetime dynamics (pipe age 10-50 years), and the influences of pipe types (premise plumbing vs. service line) and pipe materials (S-Zn vs. S-PE).


Subject(s)
Drinking Water , Sanitary Engineering , Water Supply , RNA, Ribosomal, 16S/genetics , Water Microbiology , Bacteria/genetics , Biofilms , Steel , Drinking Water/microbiology
20.
Water Res ; 253: 121109, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38377920

ABSTRACT

Running cold and hot water in buildings is a widely established commodity. However, interests regarding hygiene and microbiological aspects had so far been focussed on cold water. Little attention has been given to the microbiology of domestic hot-water installations (DHWIs), except for aspects of pathogenic Legionella. World-wide, regulations consider hot (or warm) water as 'heated drinking water' that must comply (cold) drinking water (DW) standards. However, the few reports that exist indicate presence and growth of microbial flora in DHWIs, even when supplied with water with disinfectant residual. Using flow cytometric (FCM) total cell counting (TCC), FCM-fingerprinting, and 16S rRNA-gene-based metagenomic analysis, the characteristics and composition of bacterial communities in cold drinking water (DW) and hot water from associated boilers (operating at 50 - 60 °C) was studied in 14 selected inhouse DW installations located in Switzerland and Austria. A sampling strategy was applied that ensured access to the bulk water phase of both, supplied cold DW and produced hot boiler water. Generally, 1.3- to 8-fold enhanced TCCs were recorded in hot water compared to those in the supplied cold DW. FCM-fingerprints of cold and corresponding hot water from individual buildings indicated different composition of cold- and hot-water microbial floras. Also, hot waters from each of the boilers sampled had its own individual FCM-fingerprint. 16S rRNA-gene-based metagenomic analysis confirmed the marked differences in composition of microbiomes. E.g., in three neighbouring houses supplied from the same public network pipe each hot-water boiler contained its own thermophilic bacterial flora. Generally, bacterial diversity in cold DW was broad, that in hot water was restricted, with mostly thermophilic strains from the families Hydrogenophilaceae, Nitrosomonadaceae and Thermaceae dominating. Batch growth assays, consisting of cold DW heated up to 50 - 60 °C and inoculated with hot water, resulted in immediate cell growth with doubling times between 5 and 10 h. When cold DW was used as an inoculum no significant growth was observed. Even boilers supplied with UVC-treated cold DW contained an actively growing microbial flora, suggesting such hot-water systems as autonomously operating, thermophilic bioreactors. The generation of assimilable organic carbon from dissolved organic carbon due to heating appears to be the driver for growth of thermophilic microbial communities. Our report suggests that a man-made microbial ecosystem, very close to us all and of potential hygienic importance, may have been overlooked so far. Despite consumers having been exposed to microbial hot-water flora for a long time, with no major pathogens so far been associated specifically with hot-water usage (except for Legionella), the role of harmless thermophiles and their interaction with potential human pathogens able to grow at elevated temperatures in DHWIs remains to be investigated.


Subject(s)
Drinking Water , Legionella , Humans , Drinking Water/microbiology , RNA, Ribosomal, 16S , Ecosystem , Water Supply , Bacteria/genetics , Water Microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...