Interv Cardiol Clin ; 13(3): 355-368, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839169

ABSTRACT

Transcatheter ductal closure has proven to be safe and effective to occlude the patent ductus arteriosus (PDA) in premature infants. We have developed a robust multidisciplinary PDA program. After gaining experience performing transcatheter ductal closure in the cardiac catheterization laboratory, we transitioned to performing the procedure at the patient's bedside in the neonatal intensive care unit using echocardiographic guidance. The bedside approach has the potential to expand this therapy to patients who currently undergo expectant PDA management because of lack of availability of this therapy, and allow for earlier referral, which will reduce time of exposure to this pathologic shunt.


Subject(s)
Cardiac Catheterization , Ductus Arteriosus, Patent , Infant, Premature , Humans , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/diagnosis , Infant, Newborn , Cardiac Catheterization/methods , Septal Occluder Device , Echocardiography/methods
2.
Interv Cardiol Clin ; 13(3): 421-430, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839174

ABSTRACT

Since PDA stenting was first attempted in the early 1990s, significant technical advancements have improved outcomes and some centers have even transitioned to exclusive PDA stenting for all infants with duct-dependent pulmonary circulation. In addition to its use in infants with duct-dependent pulmonary circulation, PDA stenting has also been adapted as a percutaneous palliative option for suprasystemic pulmonary arterial hypertension and as a component of the hybrid procedure. In this article, the authors aim to review indications and outcomes for PDA stenting, describe the procedure, and discuss future directions.


Subject(s)
Ductus Arteriosus, Patent , Stents , Humans , Ductus Arteriosus, Patent/surgery , Cardiac Catheterization/methods , Palliative Care/methods , Treatment Outcome
3.
J Cardiothorac Surg ; 19(1): 319, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38840135

ABSTRACT

BACKGROUND: Aberrant left coronary artery from pulmonary artery (ALCAPA) is a very rare congenital heart defect. Its coexistence with patent ductus arteriosus (PDA) is extremely rare. The high pressures created by the left-to-right shunt in the pulmonary arteries can delay symptoms and create a real challenge in diagnosing ALCAPA. Missing this diagnosis can have severe results, including extensive ischemia and sudden death. CASE PRESENTATION: We present a case of an infant born with a large PDA. Initially treated conservatively, however, due to congestive heart failure and lack of weight gain, she underwent surgical ligation of the PDA at the age of four and a half months. Following surgery, she developed pulmonary edema. Echocardiography revealed decreased ventricular function. ECG revealed ST elevations on lateral leads, and serum troponin was significantly increased. The patient underwent cardiac magnetic resonance imaging (MRI), which revealed signs of wall ischemia and decreased function of the left ventricle (LV) with unclear coronary anatomy. Diagnostic catheterization revealed an ALCAPA. She underwent surgical intervention, and the left coronary artery was re-implanted in the aortic sinus. Follow-up revealed slow improvement of cardiac function. DISCUSSION AND LITERATURE REVIEW: The coexistence of PDA and ALCAPA is a very rare occurrence. We found at least 10 reported cases in the literature. Delayed diagnosis might be detrimental. The prognosis of these patients is variable. CONCLUSION: An unusual post-surgical course following PDA repair requires a high index of suspicion and appropriate evaluation for ALCAPA, preferably with angiography.


Subject(s)
Ductus Arteriosus, Patent , Pulmonary Artery , Humans , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/complications , Ductus Arteriosus, Patent/diagnosis , Ductus Arteriosus, Patent/diagnostic imaging , Female , Pulmonary Artery/abnormalities , Pulmonary Artery/surgery , Pulmonary Artery/diagnostic imaging , Infant , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/diagnosis , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnostic imaging , Echocardiography , Coronary Vessels/surgery , Coronary Vessels/diagnostic imaging , Bland White Garland Syndrome/surgery , Bland White Garland Syndrome/diagnosis , Bland White Garland Syndrome/complications
4.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38724226

ABSTRACT

OBJECTIVES: The goal was to evaluate neonatal outcomes based on treatment strategies and time points for haemodynamically significant patent ductus arteriosus (hsPDA) in very-low-birth-weight preterm infants, with a particular focus on surgical closure. METHODS: This retrospective study included very-low-birth-weight infants born between 2014 and 2021 who received active treatment for hsPDA. Neonatal outcomes were compared between (i) primary surgical closure versus primary ibuprofen; (ii) early (<14th post-natal day) versus late primary surgical closure (≥14th post-natal day); and (iii) primary versus secondary surgical closure after ibuprofen failure. Further analysis using 1:1 propensity score matching was performed. Logistic regression was conducted to analyse the risk factors for post-ligation cardiac syndrome (PLCS) and/or acute kidney injury (AKI). RESULTS: A total of 145 infants with hsPDA underwent active treatment for closure. The in-hospital death rate and the incidence of severe bronchopulmonary dysplasia (BPD) were similar between the primary surgical closure group and the primary ibuprofen group in a 1:1 matched analysis. Severe BPD was significantly higher in the late surgical closure group than in the early primary surgical closure group with 1:1 propensity score matching (72.7% vs 40.9%, P=0.033). The secondary surgical closure group showed the mildest clinical condition; however, the probability of PLCS/AKI was highest (38.6%) compared to the early (15.2%) or the late primary surgical group (28.1%, P<0.001), especially in extremely premature infants (gestational age < 28 weeks). CONCLUSIONS: Surgical patent ductus arteriosus closure is not inferior to pharmacologic treatment. Considering the harmful effect of a prolonged patent ductus arteriosus shunt exposure, a timely decision and timely efforts should be made to minimize the risk of severe BPD and PLCS/AKI after surgical closure.


Subject(s)
Ductus Arteriosus, Patent , Ibuprofen , Infant, Very Low Birth Weight , Humans , Ductus Arteriosus, Patent/surgery , Infant, Newborn , Retrospective Studies , Male , Female , Ibuprofen/therapeutic use , Ligation/methods , Infant, Premature , Gestational Age , Propensity Score , Cardiac Surgical Procedures/methods , Cardiac Surgical Procedures/adverse effects , Treatment Outcome , Risk Factors
5.
BMC Pediatr ; 24(1): 376, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822298

ABSTRACT

BACKGROUND: Patent ductus arteriosus (PDA) is commonly encountered morbidity which often occurs as up to 60% of extremely preterm infants born at < 29 weeks gestational age (GA). PURPOSE: This study aims to assess the clinical risk factors associated with PDA ligation among very low birth weight infants (VLBWI) and evaluate the neurodevelopmental outcomes of those who underwent PDA ligation. METHODS: A total of 540 VLBWI were initially diagnosed with PDA in our 50-bed level IV NICU at Seoul St. Mary's Hospital, The Catholic University of Korea, between January 2015 and June 2023. Among these 540 VLBWI with PDA, only 221 had consistent hemodynamically significant (hs) PDA which required intervention including fluid restriction, medical treatment, or surgical ligation. In this study, only those 221 VLBWI with hsPDA who underwent neurodevelopmental assessment at corrected 18-24 months of age were included in this study analysis. RESULTS: Out of 221 VLBWI diagnosed with hemodynamically significant (hs) PDA, 133 (60.2%) underwent PDA ligation, while the remaining 88 (39.8%) had their hs PDAs closed either medically or with fluid restriction. The mean gestational age and birth weight were significantly lower in PDA ligation group compared to no PDA ligation group (27.02 ± 2.17 vs. 27.98 ± 2.36, 907.31 ± 258.36 vs. 1006.07 ± 283.65, p = 0.001, 0.008). Resuscitation including intubation at delivery and intraventricular hemorrhage (IVH) (grade ≥ 3) were significantly higher in PDA ligation group. The clinical outcomes in the PDA ligation group revealed significantly worse oucomes compared to the no PDA ligation group. Both resuscitation, including intubation at delivery, and IVH (grade ≥ 3), consistently exhibited an increased risk for PDA ligation in a multivariable logistic regression analysis. Concerning neurodevelopmental outcomes, infants who underwent PDA ligation demonstrated significantly lower cognitive scores. However, only IVH (grade ≥ 3) and PVL were consistently associated with an increased risk of abnormal neurodevelopment at the corrected age of 18-24 months. CONCLUSION: In our study, despite the consistent association between cognitive developmental delays in VLBWI who underwent PDA ligation, we observed that sicker and more vulnerable VLBWIs, specifically those experincing severe IVH, consistently exhibited an increased risk for both PDA ligation and abnormal neurodevelopment at the corrected age of 18-24 months.


Subject(s)
Ductus Arteriosus, Patent , Infant, Very Low Birth Weight , Humans , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/complications , Ligation , Female , Male , Risk Factors , Infant, Newborn , Infant , Retrospective Studies , Child, Preschool , Neurodevelopmental Disorders/etiology , Neurodevelopmental Disorders/epidemiology , Gestational Age
6.
Article in German | MEDLINE | ID: mdl-38701804

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the signalement, clinical features, and echocardiographic findings of cats diagnosed with patent ductus arteriosus (PDA) as well as short- and medium-term outcome after successful ligation of the PDA. MATERIAL AND METHODS: Over a 10-year period 17 cats were diagnosed with PDA by transthoracic echocardiography. Thirteen cats were surgically treated by thoracotomy and ligation of the PDA. RESULTS: In all cats, a heart murmur was detected. In 88.2% of the cases, this presented as grade 4 out of 6 murmur (15/17 cats). A continuous murmur was more common (10/17 cats; 58.9%) than a systolic murmur (7/17 cats; 41.1%). Echocardiography showed that left ventricular internal diameter end diastole (LVIDd) and left ventricular internal diameter end systole (LVIDs) were significantly above reference values in the majority of cats. Mean diameter of the PDA measured at the widest point of the vessel was 3.4 mm (± 1.08 mm) and mean maximum flow velocity amounted to 5,06 m/sec (2,6m/sec-6,4m/sec). Surgery was successfully performed in all cats treated by surgical ligation and all of these patients were discharged after postoperative inpatient therapy. One cat experienced perioperative bleeding from the PDA, which was stopped efficaciously. This cat exhibited a residual shunt directly postoperatively; this could no longer be visualized in a re-check echocardiography 3 months later. Six cats were followed over a longer period of time. CONCLUSIONS: The surgical prognosis in this case study is very good with a postoperative survival rate of 100%. CLINICAL RELEVANCE: Surgical treatment of PDA is curative in animals not displaying advanced cardiac lesions. The auscultation of a heart murmur can provide initial findings indicative of PDA. Therefore, cardiac auscultation is warranted at every first presentation of a kitten. It must however be taken into consideration that not every cat with PDA necessarily has a continuous murmur but may display a systolic heart murmur. Therefore, it is important give utmost attention to the patients' clinical signs.


Subject(s)
Cat Diseases , Ductus Arteriosus, Patent , Echocardiography , Animals , Cats , Ductus Arteriosus, Patent/veterinary , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/diagnosis , Cat Diseases/surgery , Cat Diseases/diagnosis , Retrospective Studies , Echocardiography/veterinary , Ligation/veterinary , Heart Murmurs/veterinary , Heart Murmurs/diagnosis , Heart Murmurs/surgery , Heart Murmurs/etiology , Female , Male
7.
BMC Pediatr ; 24(1): 277, 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38678190

ABSTRACT

OBJECTIVE: This study aimed to compare the efficacy of neurally adjusted ventilatory assist (NAVA) to synchronized intermittent mandatory ventilation (SIMV) in preterm infants requiring mechanical ventilation after patent ductus arteriosus (PDA) ligation. METHODS: A retrospective analysis was conducted on intubated preterm infants who underwent PDA ligation at our hospital from July 2021 to January 2023. Infants were divided into NAVA or SIMV groups based on the ventilation mode after surgery. RESULTS: Fifty preterm infants were included. During treatment, peak inspiratory pressure (PIP) and mean airway pressure (MAP) were lower with NAVA compared to SIMV (PIP: 19.1 ± 2.9 vs. 22.4 ± 3.6 cmH2O, P < 0.001; MAP: 9.1 ± 1.8 vs. 10.9 ± 2.7 cmH2O, P = 0.002). PaO2 and PaO2/FiO2 were higher with NAVA (PaO2: 94.0 ± 11.7 vs. 84.8 ± 15.8 mmHg, P = 0.031; PaO2/FiO2: 267 [220-322] vs. 232 [186-290] mmHg, P = 0.025). Less sedation was required with NAVA (midazolam: 1.5 ± 0.5 vs. 1.1 ± 0.3 µg/kg/min, P < 0.001). CONCLUSION: Compared to SIMV, early use of NAVA post PDA ligation in preterm infants was associated with decreased PIP and MAP. Early NAVA was also associated with reduced sedation needs and improved oxygenation. However, further studies are warranted to quantify the benefits of NAVA ventilation.


Subject(s)
Ductus Arteriosus, Patent , Infant, Premature , Interactive Ventilatory Support , Intermittent Positive-Pressure Ventilation , Humans , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/therapy , Retrospective Studies , Infant, Newborn , Male , Female , Ligation/methods , Interactive Ventilatory Support/methods , Intermittent Positive-Pressure Ventilation/methods , Respiratory Distress Syndrome, Newborn/therapy
8.
Eur J Pediatr ; 183(6): 2753-2761, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38558310

ABSTRACT

Percutaneous catheter-based closure is increasingly utilized in premature newborns. While near-infrared spectroscopy (NIRS) has been examined for assessment of interventional closure in surgical ligation, its application in percutaneous transcatheter closure remains unexplored. This study aims to assess cerebral and renal hemodynamic changes using NIRS during percutaneous closure compared to surgical closure in preterm infants. A prospective observational study enrolled preterm infants born at 32 weeks of gestation or less and diagnosed with hsPDA between January 2020 and December 2022. These infants received either surgical or catheter-based closure of the PDA. Cerebral and renal oxygen saturation was monitored using the INVOS 5100 device from 12 h before the intervention until 24 h after. Linear mixed-effects models were used to analyze time-dependent variables. Twenty-two patients were enrolled, with catheter-based closure performed in 16 cases and conventional surgery in 6 cases. Following ductal closure, a significant increase in renal and cerebral oximetry was observed alongside a decrease in renal and cerebral tissue oxygen extraction. These changes were particularly pronounced in the renal territory. No differences were detected between catheterization and surgical closure.   Conclusion: An improvement in cerebral and renal oximetry following hsPDA closure was observed. However, we did not identify differences in this pattern based on the type of interventional procedure for PDA, whether surgery or catheterization. What is Known: • The presence of a significant ductus is common in premature patients. Studies have shown that it affects cerebral and renal hemodynamics negatively, leading to decreased oximetry values in these areas. It has been reported that closure of the ductus, either pharmacologically or surgically, results in improved oximetry values. What is New: • This study assess the impact of percutaneous closure of ductus, revealing increased oximetry values in cerebral and renal territories without significant differences compared to surgical ligation. Notably, renal oximetry values showed a greater increase, underscoring the importance of multi-location monitoring.


Subject(s)
Ductus Arteriosus, Patent , Infant, Premature , Oximetry , Spectroscopy, Near-Infrared , Humans , Infant, Newborn , Prospective Studies , Female , Male , Oximetry/methods , Spectroscopy, Near-Infrared/methods , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/physiopathology , Kidney/physiopathology , Kidney/blood supply , Cardiac Catheterization/methods , Cerebrovascular Circulation/physiology , Brain/metabolism , Brain/blood supply
10.
Early Hum Dev ; 191: 105976, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38452632

ABSTRACT

BACKGROUND: Patent ductus arteriosus (PDA) in premature infants is associated with adverse clinical outcomes. Mode and timing of treatment are still controversial. Data are limited in the most extremely premature infants <26 weeks of gestational age (GA), where clinical problems are most significant and patients are most vulnerable. AIMS: To investigate whether different approaches to surgical closure of PDA in two large Swedish centers has an impact on clinical outcomes including mortality in extremely preterm infants born <26 weeks GA. STUDY DESIGN: Retrospective, two-center, cohort study. SUBJECTS: Infants born at 22+0-25+6 weeks GA between 2010 and 2016 at Uppsala University Children's Hospital (UUCH; n = 228) and Queen Silvia Children's Hospital Gothenburg (QSCHG; n = 220). MAIN OUTCOME MEASURES: Survival, bronchopulmonary dysplasia (BPD), and retinopathy of prematurity (ROP). RESULTS: Surgical closure of PDA was more common and performed earlier at QSCHG (50 % vs 16 %; median age 11 vs 44 days; p < 0.01). Survival was similar in both centres. There was a higher incidence of severe BPD and longer duration of mechanical ventilation at UUCH (p < 0.01). There was a higher incidence of ROP, IVH and sepsis at QSCH (p < 0.05, p < 0.01 and p < 0.01). A sub-group analysis matching all surgically treated infants at QSCHG with infants at UUCH with the same GA showed similar results as the total cohort. CONCLUSION: Earlier and higher rate of surgical PDA closure in this cohort of extremely preterms born <26 weeks GA did not impact mortality but was associated with lower rates of severe BPD and higher rates of severe ROP.


Subject(s)
Bronchopulmonary Dysplasia , Ductus Arteriosus, Patent , Retinopathy of Prematurity , Infant , Female , Child , Infant, Newborn , Humans , Infant, Extremely Premature , Ductus Arteriosus, Patent/epidemiology , Ductus Arteriosus, Patent/surgery , Gestational Age , Retrospective Studies , Cohort Studies , Bronchopulmonary Dysplasia/epidemiology , Bronchopulmonary Dysplasia/complications , Retinopathy of Prematurity/epidemiology , Retinopathy of Prematurity/surgery
12.
World J Pediatr ; 20(5): 470-480, 2024 May.
Article in English | MEDLINE | ID: mdl-38356035

ABSTRACT

BACKGROUND: Longer hospitalizations for preterm infants with bronchopulmonary dysplasia (BPD) delay developmental outcomes, increase the risk for hospital-acquired complications, and exert a substantial socioeconomic burden. This study aimed to identify factors associated with an extended length of stay (LOS) at different levels of severity of BPD. METHODS: A cohort study was conducted using the Korean Neonatal Network registry of very low birth weight infants with BPD between 2013 and 2017 through retrospective analysis. RESULTS: A total of 4263 infants were diagnosed with BPD. For mild BPD, infants requiring surgical treatment for patent ductus arteriosus needed a longer LOS [eadjusted ß coefficients (adj ß) 1.041; 95% confidence interval (CI): 0.01-0.08] and hydrocephalus (eadj ß 1.094; 95% CI 0.01-0.17). In moderate BPD, infants administered steroids or with intraventricular hemorrhage required a longer LOS (eadj ß 1.041; 95% CI 0.00-0.07 and eadj ß 1.271; 95% CI 0.11-0.38, respectively). In severe BPD, infants with comorbidities required a longer LOS: pulmonary hypertension (eadj ß 1.174; 95% CI 0.09-0.23), administrated steroid for BPD (eadj ß 1.116; 95% CI 0.07-0.14), sepsis (eadj ß 1.062; 95% CI 0.01-0.11), patent ductus arteriosus requiring surgical ligation (eadj ß 1.041; 95% CI 0.00-0.08), and intraventricular hemorrhage (eadj ß 1.016; 95% CI 0.05-0.26). Additionally, the higher the clinical risk index score, the longer the LOS needed for infants in all groups. CONCLUSIONS: The factors affecting LOS differed according to the severity of BPD. Individualized approaches to reducing LOS may be devised using knowledge of the various risk factors affecting LOS by BPD severity.


Subject(s)
Bronchopulmonary Dysplasia , Length of Stay , Severity of Illness Index , Humans , Bronchopulmonary Dysplasia/epidemiology , Bronchopulmonary Dysplasia/therapy , Republic of Korea/epidemiology , Female , Male , Infant, Newborn , Length of Stay/statistics & numerical data , Retrospective Studies , Cohort Studies , Infant, Premature , Infant, Very Low Birth Weight , Risk Factors , Registries , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/epidemiology
13.
Eur J Pediatr ; 183(5): 2193-2201, 2024 May.
Article in English | MEDLINE | ID: mdl-38381375

ABSTRACT

Transcatheter patent ductus arteriosus (PDA) closure is a safe and effective alternative to surgical ligation in low-body-weight infants. Post-ligation cardiac syndrome (PLCS) is defined as severe hemodynamic and respiratory collapse within 24 h of PDA closure, requiring initiation or an increase of an inotropic agent by > 20% of preligation dosing and an absolute increase of at least 20% in ventilation parameters compared with the preoperative value. Whilst PLCS is routinely observed after surgery, its incidence remains poorly described following transcatheter closure. This study aimed to compare the incidence of PLCS after surgical versus transcatheter closure of PDA in low-body-weight premature infants. Propensity scores were used to compare surgical (N = 78) and transcatheter (N = 76) groups of preterm infants who underwent PDA closure at a procedural weight less than 2000 g in two tertiary institutions between 2009 and 2021. The primary outcome was the incidence of PLCS. Secondary outcomes included overall mortality before discharge, risk factors for PLCS, and post-procedural complications. Procedural success was 100% in both groups. After matching, transcatheter group experienced no PLCS vs 15% in the surgical group (p = 0.012). Furthermore, overall mortality (2% vs 17%; p = 0.03) and major complications (2% vs 23%; p = 0.002) were higher in the surgical group. Surgery (100% vs 47%; p < 0.01), gestation age (25 ± 1 vs 26 ± 2 weeks, p < 0.05) and inotropic support before closure (90% vs 29%; p < 0.001) were associated with PLCS occurrence.          Conclusion: Transcatheter PDA closure may be equally effective but safer than surgical PDA closure in low-body-weight premature infants. What is Known: • Post-ligation cardiac syndrome is a serious and common complication of surgical closure of the ductus arteriosus in preterm infants. • Transcatheter closure of preterm ductus arteriosus is a safe and effective technique that is becoming more and more common worldwide. What is New: • Device closure is safer than surgical ligation for patent ductus arteriosus closure in preterm infants and may be the first-line non-pharmacological therapeutic option in this indication in experienced teams. • Our findings should encourage neonatologists and pediatric cardiologists to start and/or strengthen a durable interventional program for transcatheter PDA closure in premature infants.


Subject(s)
Cardiac Catheterization , Ductus Arteriosus, Patent , Infant, Premature , Postoperative Complications , Humans , Ductus Arteriosus, Patent/surgery , Retrospective Studies , Infant, Newborn , Female , Ligation/methods , Ligation/adverse effects , Male , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Infant, Low Birth Weight , Incidence , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/methods , Syndrome , Propensity Score , Septal Occluder Device , Risk Factors , Infant, Premature, Diseases/surgery , Infant, Premature, Diseases/etiology , Infant, Premature, Diseases/therapy , Infant, Premature, Diseases/epidemiology
14.
West Afr J Med ; 41(1): 87-91, 2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38412515

ABSTRACT

It is not uncommon for congenital heart defects to occur in clusters. Those involving a right to left heart shunt commonly cause cyanosis and finger clubbing. Differential clubbing involving only the lower limb digits is a strong pointer to the presence of patent ductus arteriosus with reversal of shunt. We report a case of 25-year-old man with effort intolerance and differential clubbing. He was found to have the uncommon triad of patent ductus arteriosus, ventricular septal defect and supravalvular ring mitral stenosis. The presence of differential clubbing on a background of patent ductus arteriosus usually indicates a reversal of shunt and negates surgical intervention. This general rule may however not apply with co-existing mitral stenosis as the elevated pulmonary pressure may be predominantly post-capillary. The finding of mitral stenosis in a patient with patent ductus arteriosus and differential limb clubbing may signify a good prognostic surgical outcome.


Il n'est pas rare que des malformations cardiaques congénitales surviennent en clusters. Celles impliquant un shunt cardiaque droitegauche provoquent souvent une cyanose et un hippocratisme digital. L'hippocratisme digital différentiel touchant uniquement les orteils des membres inférieurs est un indicateur fort de la présence d'un canal artériel persistant avec inversion du shunt. Nous rapportons le cas d'un homme de 25 ans présentant une intolérance à l'effort et un hippocratisme digital différentiel. Il a été diagnostiqué avec la triade peu commune de canal artériel persistant, de communication interventriculaire et de sténose mitrale à anneau supravalvulaire. La présence d'un hippocratisme digital différentiel sur un fond de canal artériel persistant indique généralement une inversion du shunt et exclut une intervention chirurgicale. Cependant, cette règle générale peut ne pas s'appliquer en présence d'une sténose mitrale concomitante, car la pression pulmonaire élevée peut être principalement post-capillaire. La découverte d'une sténose mitrale chez un patient atteint de canal artériel persistant et d'un hippocratisme digital différentiel peut indiquer un bon pronostic pour l'intervention chirurgicale.


Subject(s)
Ductus Arteriosus, Patent , Heart Septal Defects, Ventricular , Mitral Valve Stenosis , Male , Humans , Adult , Ductus Arteriosus, Patent/complications , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Mitral Valve Stenosis/complications , Mitral Valve Stenosis/diagnostic imaging , Heart Septal Defects, Ventricular/complications , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery
15.
J Vet Cardiol ; 52: 35-42, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38422726

ABSTRACT

INTRODUCTION: Small dogs with patent ductus arteriosus (PDA) may be unable to undergo transesophageal echocardiography (TEE) with traditional probes. OBJECTIVES: To report the utility of TEE using a microprobe in dogs weighing less than 4 kg diagnosed with PDA for determination of transcatheter procedural candidacy, device selection, and intraoperative procedural guidance. ANIMALS: Eight dogs weighing less than 4 kg diagnosed with PDA. MATERIALS AND METHODS: All dogs had standard transthoracic echocardiography and microprobe TEE imaging. The quality of TEE images was graded as optimal, adequate, or poor. The ability of TEE to assess PDA anatomy, determine procedural candidacy, provide procedural guidance, detect deployed devices, and assess residual flow was recorded. RESULTS: The median age of included dogs was 6.4 months (range: 3.2-15.7 months) and the median body weight was 2.2 kg (range: 1.4-3.8 kg). Microprobe TEE images were adequate or optimal in all dogs and were integral for guiding procedural candidacy decisions. Transcatheter procedures were not pursued in two dogs based on TEE images. In the other six dogs, TEE procedural guidance was useful during transvenous (n = 5) and transarterial (n = 1) PDA occlusion attempts. Each deployed device (n = 4) was easily detected with the TEE microprobe. Real-time confirmation of adequate device sizing and placement was possible prior to release and residual flow could be monitored after release. CONCLUSIONS: Transesophageal echocardiography using a microprobe in dogs weighing less than 4 kg diagnosed with PDA allowed for characterization of PDA anatomy and determination of transcatheter procedural candidacy. Microprobe TEE images were integral for PDA device selection and offered valuable intraoperative procedural guidance.


Subject(s)
Cardiac Catheterization , Dog Diseases , Ductus Arteriosus, Patent , Echocardiography, Transesophageal , Animals , Dogs , Ductus Arteriosus, Patent/veterinary , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/diagnostic imaging , Echocardiography, Transesophageal/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Cardiac Catheterization/veterinary , Cardiac Catheterization/instrumentation , Female , Male
16.
J Vet Cardiol ; 51: 214-219, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38232623

ABSTRACT

A 16-month-old Labrador-Poodle cross (case 1) and a 3-month-old German shorthaired pointer (case 2) were referred for patent ductus arteriosus (PDA) occlusion. Two-dimensional transthoracic and two- and three-dimensional transesophageal echocardiography revealed a window-like PDA characterized by a wide and short ductus. Due to the atypical PDA morphology with no ampulla in case 1, ductal occlusion was attempted with non-canine-specific Amplatzer occluder devices. However, these were too small and failed to remain stable. Amplatz Canine Duct Occluder (ACDO) devices were used with success in both cases. Due to the defects' morphology, the proximal ACDO disc protruded into the aorta but there were no signs of obstruction to aortic blood flow 16 months (case 1) and 1 month (case 2) post-occlusion. We describe two cases of a window-like type PDA that were successfully occluded with an ACDO.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Septal Occluder Device , Dogs , Animals , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Echocardiography, Transesophageal/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Septal Occluder Device/veterinary , Cardiac Catheterization/veterinary , Treatment Outcome
17.
Cardiol Young ; 34(2): 370-372, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37434447

ABSTRACT

Type A3 truncus arteriosus describes pulmonary atresia with non-confluent mediastinal pulmonary arteries in which one pulmonary artery arises from a patent ductus arteriosus and the contralateral pulmonary artery from the aorta resulting in ductal dependent pulmonary blood flow. We describe a premature neonate with caudal regression syndrome and type A3 truncus arteriosus who was palliated with a ductal stent allowing completion of a prolonged neonatal ICU hospitalisation for multiple comorbidities.


Subject(s)
Ductus Arteriosus, Patent , Ductus Arteriosus , Truncus Arteriosus, Persistent , Infant, Newborn , Humans , Ductus Arteriosus, Patent/complications , Ductus Arteriosus, Patent/surgery , Truncus Arteriosus , Truncus Arteriosus, Persistent/surgery , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Stents
18.
Cardiol Young ; 34(1): 157-162, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37283091

ABSTRACT

In this multi-centre study, the mid- to long-term efficacy and safety of the Amplatzer Piccolo Occluder in patent ductus arteriosus closure in premature and term infants as well as children were discussed. Methods. Between 2016 and 2021, 645 patients, 152 of whom were less than 1 month old, underwent ductus closure with the Piccolo device from five different centres in Turkey. The median age of the patients was 2.2 years, and the mean narrowest point of duct diameter was 1.8 mm. Sixty-two patients weighed ≤ 1.5 kg, 90 patients 1.5-3 kg, and the mean follow-up was 20.4 months. In 396, the duct was closed by the retrograde route. Ductal anatomy was Type A in 285, C in 72, E in 171, and F in 64 patients. Fluoroscopy duration was 6.2 min. The procedure success rate was 99.1%. Device embolisation occurred in 13 patients (2%), and 11 were retrieved with a snare. Cardiac perforation and death developed in one premature baby. The left pulmonary artery and the descending aorta stenosis were observed in 3 (0.4%) and in 5 patients (0.5%). Results. Piccolo device is safe and effective in closing ductus in all age groups. It has low profile for use in premature and newborn babies, a small embolisation risk, and a low residual shunt rate after closure. Conclusion. The Piccolo device can be considered as close an ideal occluder. The lower profile, smaller delivery catheter size, and symmetry of this device allow for a venous or arterial approach.


Subject(s)
Ductus Arteriosus, Patent , Premature Birth , Septal Occluder Device , Child , Infant , Infant, Newborn , Female , Humans , Adolescent , Child, Preschool , Treatment Outcome , Ductus Arteriosus, Patent/surgery , Cardiac Catheterization/methods , Infant, Premature
19.
Pediatr Neonatol ; 65(2): 111-116, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38114414

ABSTRACT

BACKGROUND: Gastrointestinal perforation in extremely low birth weight infants, characterized by its rapid onset, multiple complications, and critical condition, poses a significant risk of infant mortality. The aim of this study was to investigate the clinical characteristics of pneumoperitoneum in extremely low birth weight infants (ELBWI) and explore the risk factors associated with gastrointestinal perforation in very low birth weight preterm infants. Additionally, we shared our surgical experiences in managing gastrointestinal perforation among extremely low birth weight infants. METHODS: The Department of Neonatology at Chengdu Women and Children's Central Hospital conducted a retrospective study on gastrointestinal perforation in extremely low birth weight infants (birth weight <1000 g) who were admitted between 2014 and 2021. After baseline analysis and comparing it with the control group, we identified the risk factors associated with gastrointestinal perforation in ELBWI by multiple logistic regression analysis. The Kaplan-Meier analysis was performed to assess the adverse effect of gastrointestinal perforation for survival in ELBW infants. Cox multivariate regression analysis was used to evaluate hazard level of different variables for ELBW infants survival. RESULTS: Hemodynamically significant patent ductus arteriosus (hsPDA)(p = 0.043, OR = 2.779) and sepsis (p = 0.014, OR = 2.265) were significant risk factors for gastrointestinal perforation in extremely low birth weight infants. The Cox proportional hazard model revealed that intraventricular hemorrhage (HR = 2.854, p<0.001) Sepsis (HR = 1.645, p = 0.015) and gastrointestinal perforation (HR = 1.876, p = 0.008) had detrimental effects on the survival of extremely low birth weight infants; conversely, ibuprofen (HR = 0.304, p<0.001) and blood transfusion (HR = 0.372, p<0.001) are beneficial factors for their survival. The preoperative indicators of infection in infants with spontaneous intestinal perforation (SIP) were significantly better than those in the necrotizing enterocolitis (NEC) group (p < 0.05). CONCLUSIONS: Gastrointestinal perforation poses a significant threat the survival of extremely low birth weight (ELBW) infants, with hsPDA and sepsis serving as predisposing factors for gastrointestinal perforation. The gastrointestinal perforation caused by various diseases exhibits distinct clinical characteristics, necessitating tailored surgical approaches based on operative conditions.


Subject(s)
Ductus Arteriosus, Patent , Intestinal Perforation , Sepsis , Infant , Child , Infant, Newborn , Humans , Female , Infant, Extremely Low Birth Weight , Infant, Premature , Retrospective Studies , Birth Weight , Ductus Arteriosus, Patent/surgery , Intestinal Perforation/epidemiology , Intestinal Perforation/etiology , Intestinal Perforation/surgery
20.
Curr Probl Cardiol ; 49(2): 102334, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38142948

ABSTRACT

Adult patent ductus arteriosus (PDA) repair surgery often involves hypothermic cardiopulmonary bypass (CPB) and is associated with postoperative neurological complications. Our study evaluates brain function during PDA surgery using regional cerebral oxygen saturation (rSO2) and bispectral index (BIS) monitoring to mitigate these complications. Patients were categorized into moderate (26-31 â„ƒ) and mild (32-35 â„ƒ) hypothermia groups. Findings indicate a positive correlation between PDA diameter and pulmonary artery systolic blood pressure, and a strong correlation between delirium and average rSO2-AUC. The mild hypothermia group had longer extubation and hospitalization times. During CPB, rSO2 levels fluctuated significantly, and EEG analysis revealed changes in brain wave patterns. One case of nerve injury in the mild hypothermia group showed incomplete recovery after a year. Our results advocate for moderate hypothermia during CPB in adult PDA repair, suggesting that combined rSO2 and BIS monitoring can reduce neurological complications post-surgery.


Subject(s)
Brain , Ductus Arteriosus, Patent , Adult , Humans , Brain/physiology , Cardiopulmonary Bypass/methods , Ductus Arteriosus, Patent/surgery , Hypothermia, Induced