Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 299
Filter
1.
Article in German | MEDLINE | ID: mdl-38701804

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the signalement, clinical features, and echocardiographic findings of cats diagnosed with patent ductus arteriosus (PDA) as well as short- and medium-term outcome after successful ligation of the PDA. MATERIAL AND METHODS: Over a 10-year period 17 cats were diagnosed with PDA by transthoracic echocardiography. Thirteen cats were surgically treated by thoracotomy and ligation of the PDA. RESULTS: In all cats, a heart murmur was detected. In 88.2% of the cases, this presented as grade 4 out of 6 murmur (15/17 cats). A continuous murmur was more common (10/17 cats; 58.9%) than a systolic murmur (7/17 cats; 41.1%). Echocardiography showed that left ventricular internal diameter end diastole (LVIDd) and left ventricular internal diameter end systole (LVIDs) were significantly above reference values in the majority of cats. Mean diameter of the PDA measured at the widest point of the vessel was 3.4 mm (± 1.08 mm) and mean maximum flow velocity amounted to 5,06 m/sec (2,6m/sec-6,4m/sec). Surgery was successfully performed in all cats treated by surgical ligation and all of these patients were discharged after postoperative inpatient therapy. One cat experienced perioperative bleeding from the PDA, which was stopped efficaciously. This cat exhibited a residual shunt directly postoperatively; this could no longer be visualized in a re-check echocardiography 3 months later. Six cats were followed over a longer period of time. CONCLUSIONS: The surgical prognosis in this case study is very good with a postoperative survival rate of 100%. CLINICAL RELEVANCE: Surgical treatment of PDA is curative in animals not displaying advanced cardiac lesions. The auscultation of a heart murmur can provide initial findings indicative of PDA. Therefore, cardiac auscultation is warranted at every first presentation of a kitten. It must however be taken into consideration that not every cat with PDA necessarily has a continuous murmur but may display a systolic heart murmur. Therefore, it is important give utmost attention to the patients' clinical signs.


Subject(s)
Cat Diseases , Ductus Arteriosus, Patent , Echocardiography , Animals , Cats , Ductus Arteriosus, Patent/veterinary , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/diagnosis , Cat Diseases/surgery , Cat Diseases/diagnosis , Retrospective Studies , Echocardiography/veterinary , Ligation/veterinary , Heart Murmurs/veterinary , Heart Murmurs/diagnosis , Heart Murmurs/surgery , Heart Murmurs/etiology , Female , Male
2.
J Vet Cardiol ; 52: 35-42, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38422726

ABSTRACT

INTRODUCTION: Small dogs with patent ductus arteriosus (PDA) may be unable to undergo transesophageal echocardiography (TEE) with traditional probes. OBJECTIVES: To report the utility of TEE using a microprobe in dogs weighing less than 4 kg diagnosed with PDA for determination of transcatheter procedural candidacy, device selection, and intraoperative procedural guidance. ANIMALS: Eight dogs weighing less than 4 kg diagnosed with PDA. MATERIALS AND METHODS: All dogs had standard transthoracic echocardiography and microprobe TEE imaging. The quality of TEE images was graded as optimal, adequate, or poor. The ability of TEE to assess PDA anatomy, determine procedural candidacy, provide procedural guidance, detect deployed devices, and assess residual flow was recorded. RESULTS: The median age of included dogs was 6.4 months (range: 3.2-15.7 months) and the median body weight was 2.2 kg (range: 1.4-3.8 kg). Microprobe TEE images were adequate or optimal in all dogs and were integral for guiding procedural candidacy decisions. Transcatheter procedures were not pursued in two dogs based on TEE images. In the other six dogs, TEE procedural guidance was useful during transvenous (n = 5) and transarterial (n = 1) PDA occlusion attempts. Each deployed device (n = 4) was easily detected with the TEE microprobe. Real-time confirmation of adequate device sizing and placement was possible prior to release and residual flow could be monitored after release. CONCLUSIONS: Transesophageal echocardiography using a microprobe in dogs weighing less than 4 kg diagnosed with PDA allowed for characterization of PDA anatomy and determination of transcatheter procedural candidacy. Microprobe TEE images were integral for PDA device selection and offered valuable intraoperative procedural guidance.


Subject(s)
Cardiac Catheterization , Dog Diseases , Ductus Arteriosus, Patent , Echocardiography, Transesophageal , Animals , Dogs , Ductus Arteriosus, Patent/veterinary , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/diagnostic imaging , Echocardiography, Transesophageal/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Cardiac Catheterization/veterinary , Cardiac Catheterization/instrumentation , Female , Male
3.
J Vet Cardiol ; 51: 214-219, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38232623

ABSTRACT

A 16-month-old Labrador-Poodle cross (case 1) and a 3-month-old German shorthaired pointer (case 2) were referred for patent ductus arteriosus (PDA) occlusion. Two-dimensional transthoracic and two- and three-dimensional transesophageal echocardiography revealed a window-like PDA characterized by a wide and short ductus. Due to the atypical PDA morphology with no ampulla in case 1, ductal occlusion was attempted with non-canine-specific Amplatzer occluder devices. However, these were too small and failed to remain stable. Amplatz Canine Duct Occluder (ACDO) devices were used with success in both cases. Due to the defects' morphology, the proximal ACDO disc protruded into the aorta but there were no signs of obstruction to aortic blood flow 16 months (case 1) and 1 month (case 2) post-occlusion. We describe two cases of a window-like type PDA that were successfully occluded with an ACDO.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Septal Occluder Device , Dogs , Animals , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Echocardiography, Transesophageal/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Septal Occluder Device/veterinary , Cardiac Catheterization/veterinary , Treatment Outcome
4.
J Vet Cardiol ; 52: 90-95, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38296713

ABSTRACT

A five-month-old male intact Goldendoodle presented for evaluation for peripheral cyanosis following exercise. Transthoracic echocardiography demonstrated severe right ventricular wall thickening and right atrial dilation secondary to pulmonary hypertension. An agitated saline contrast study demonstrated an interatrial right-to-left shunt. Cardiac-gated computed tomography confirmed a reverse patent ductus arteriosus. This case report highlights the utility of cardiac-gated computed tomography in identifying multi-level intra- and extra-cardiac shunts.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Tomography, X-Ray Computed , Ductus Arteriosus, Patent/veterinary , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/complications , Animals , Male , Dog Diseases/diagnostic imaging , Dogs , Tomography, X-Ray Computed/veterinary , Echocardiography/veterinary
5.
J Med Primatol ; 53(1): e12686, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37990472

ABSTRACT

We performed whole-exome sequencing using a human exome capture kit to analyze the potential genetic factors related to patent ductus arteriosus in Japanese macaques. Compared with the reference sequences of other primates, we identified potential missense variants in five genes: ADAM15, AZGP1, CSPG4, TNFRSF13B, and EPOR.


Subject(s)
Ductus Arteriosus, Patent , Humans , Animals , Ductus Arteriosus, Patent/genetics , Ductus Arteriosus, Patent/veterinary , Macaca fuscata , Exome Sequencing , Membrane Proteins/genetics , ADAM Proteins/genetics
7.
Open Vet J ; 13(11): 1478-1484, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38107222

ABSTRACT

Background: Cardiologists close most patent ductus arteriosus (PDA) defects in dogs using the Amplatz® canine duct occluder via a transarterial approach. However, this approach can be problematic in small dogs due to the small femoral artery diameter. In such cases, cardiologists have opted to use coils or vascular plugs deployed from a transvenous approach. However, in small dogs with large PDA, the risk of device protrusion into the pulmonary artery, incomplete closure, or device embolization, often leads to surgical PDA closure via thoracotomy. Case Description: The present report describes a 3-month-old male 6 kg Border collie with a large, PDA which was successfully occluded using the Amplatzer™ muscular ventricular septal defect (mVSD) device from a transvenous approach after closure attempts with an Amplatzer™ vascular plug II failed. Conclusion: This is the first case report in veterinary medicine of PDA closure with an Amplatzer™ mVSD occluder device. This approach, described in PDA closure in people, could be considered in minimally invasive PDA closure in small dogs with challenging anatomy.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Heart Septal Defects, Ventricular , Septal Occluder Device , Humans , Dogs , Male , Animals , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Septal Occluder Device/veterinary , Heart Septal Defects, Ventricular/surgery , Heart Septal Defects, Ventricular/veterinary , Pulmonary Artery , Dog Diseases/surgery
8.
J Vet Cardiol ; 49: 44-51, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37801771

ABSTRACT

A 7-week-old male Doberman presented with tachypnea, dyspnea and a VI/VI, left cranial, continuous heart murmur. Thoracic radiographs revealed severe left-sided cardiomegaly, presence of a rounded soft tissue opacity in the caudodorsal aspect of the thoracic cavity and signs of left-sided congestive heart failure. Clinical signs of heart failure were medically controlled. Echocardiography and computed tomography demonstrated a left-to-right shunting patent ductus arteriosus (PDA) in combination with a right-to-left shunting pulmonary arteriovenous malformation (PAVM) between the right main pulmonary artery and the right caudal pulmonary vein. Arterial blood gasses revealed mild hypoxemia. Transcatheter occlusion of the PDA using an Amplatz Canine Duct Occluder was performed. Four months post-operatively, echocardiography showed normal cardiac size and function with complete PDA closure. Thoracic radiographs revealed absence of the rounded opacity and resolution of cardiomegaly and vascular congestion. The PAVM was no longer visualized on repeated computed tomography and the arterial blood gasses were within normal limits. A PAVM connecting a pulmonary artery to a pulmonary vein has only rarely been reported in dogs. This report describes the presence of a congenital PAVM in combination with a PDA in a dog, which has not been previously reported in veterinary medicine.


Subject(s)
Arteriovenous Malformations , Dog Diseases , Ductus Arteriosus, Patent , Pulmonary Veins , Dogs , Animals , Male , Ductus Arteriosus, Patent/complications , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/abnormalities , Pulmonary Veins/diagnostic imaging , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Arteriovenous Malformations/complications , Arteriovenous Malformations/diagnostic imaging , Arteriovenous Malformations/veterinary , Cardiomegaly/veterinary , Cardiac Catheterization/veterinary
9.
J Vet Sci ; 24(4): e50, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37532295

ABSTRACT

This paper reports the clinical findings and surgical treatment of feline right patent ductus arteriosus (RPDA) with a left aortic arch. A two-month-old female Maine Coon was referred for an investigation of regurgitation after weaning. RPDA with a left aortic arch was diagnosed based on the echocardiographic and computed tomography (CT) findings. A right-fourth intercostal thoracotomy was found to be an appropriate approach to the duct. Preoperative diagnosis is crucial and diagnostic imaging, including radiography, echocardiography, and cardiac CT examination, is essential for determining if the aortic arch is right or left.


Subject(s)
Cat Diseases , Ductus Arteriosus, Patent , Vascular Ring , Animals , Cats , Female , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Vascular Ring/veterinary , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aorta, Thoracic/abnormalities , Tomography, X-Ray Computed , Catalase , Cat Diseases/diagnostic imaging , Cat Diseases/surgery
10.
J Vet Cardiol ; 48: 37-45, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37406392

ABSTRACT

INTRODUCTION: English springer spaniels have larger, rounder ventricles than most other breeds. How this geometry impacts responses to volume overload remains unknown. We compared left ventricular size between English springer spaniels and two similarly sized sporting breeds (Border collies and Labrador retrievers) in naturally occurring chronic left ventricular volume loading conditions (mitral regurgitation and patent ductus arteriosus [PDA]) to examine whether differences in remodelling responses exist between these breeds. ANIMALS, MATERIALS AND METHODS: We searched records for cases of mitral regurgitation and PDA in three breeds. We recorded age, sex, presence of congestive heart failure (CHF), body weight and specific echocardiographic variables. We compared normalised measures of left ventricular size between breeds. Cases with CHF were further examined as a separate group. RESULTS: One-hundred-and-ninety-one dogs were included: 110 with degenerative mitral valve disease, 42 with mitral dysplasia and 39 with PDA. One third of all cases had CHF. All measures of left ventricular size were larger in English springer spaniels in mitral regurgitation cases (P<0.001), whereas PDA cases did not differ. English springer spaniels with PDA resulting in CHF had larger systolic dimensions and volumes than similarly affected non-English Springer Spaniel dogs (P=0.003). CONCLUSIONS: English springer spaniels have greater left ventricular dimensions when exposed to chronic mitral regurgitation, compared with Border collies and Labrador retrievers, but not when exposed to volume overload from a PDA. English springer spaniels differ in their left ventricular morphology from two other sporting breeds, supporting previous studies that they have a unique cardiac morphotype.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Heart Failure , Mitral Valve Insufficiency , Dogs , Animals , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/veterinary , Mitral Valve Insufficiency/complications , Heart , Hypertrophy, Left Ventricular/diagnostic imaging , Hypertrophy, Left Ventricular/veterinary , Echocardiography/veterinary , Echocardiography/methods , Heart Failure/veterinary , Heart Failure/complications , Ductus Arteriosus, Patent/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/genetics
12.
J Vet Cardiol ; 47: 30-40, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37150018

ABSTRACT

INTRODUCTION: Occupational exposure to ionizing radiation poses health risks for veterinary interventionalists. There are limited veterinary studies evaluating radiation dose in the cardiac catheterization laboratory. The purpose of this study was to report direct radiation dose exposure to patients during common interventional cardiology procedures and compare these doses between two fluoroscopy units. ANIMALS: One hundred and fifty-four client-owned dogs. MATERIALS AND METHODS: Patient dose during procedures using a portable C-arm were retrospectively analyzed and compared to those performed in a contemporary interventional suite. Fluoroscopy equipment, procedure type, operator, patient weight, fluoroscopy time, dose area product, and air kerma were recorded and statistically modeled using univariable and multivariable linear regression to evaluate the effect of each factor. RESULTS: Patient dose population (154 dogs), comprised 61 patent ductus arteriosus occlusions, 60 balloon pulmonary valvuloplasties, and 33 pacemaker implantations. Patient dose was significantly lower in the group utilizing a newer generation fluoroscopy unit vs. the group utilizing an older portable C-arm, positively correlated with patient weight, and highest during balloon pulmonary valvuloplasties compared to patent ductus arteriosus occlusions or pacemaker implantations (all P<0.010). DISCUSSION: Newer fluoroscopy systems can be equipped with technologies that improve image quality while reducing patient dose and radiation exposure to interventional personnel. CONCLUSIONS: We documented a significant reduction in patient radiation dose using a newer fluoroscopy system as compared to an older portable C-arm for interventional cardiology procedures in animals. Improved knowledge of patient radiation dose factors may promote better radiation safety protocols in veterinary interventional cardiology.


Subject(s)
Cardiac Catheterization , Dog Diseases , Ductus Arteriosus, Patent , Animals , Dogs , Ductus Arteriosus, Patent/veterinary , Retrospective Studies , Cardiac Catheterization/adverse effects , Cardiac Catheterization/veterinary , Radiation Dosage , Fluoroscopy/adverse effects , Fluoroscopy/veterinary , Dog Diseases/etiology
13.
Vet Med Sci ; 9(4): 1477-1482, 2023 07.
Article in English | MEDLINE | ID: mdl-37243911

ABSTRACT

A 4-month-old intact female German shepherd dog was presented with a history of postprandial regurgitation, a palpably distended cervical oesophagus after eating, and poor weight gain despite a ravenous appetite. Computed tomography angiography, esophagoscopy and echocardiography identified a persistent right aortic arch with a concurrent patent ductus arteriosus (PDA) causing extraluminal oesophageal compression leading to marked segmental megaoesophagus. A heart murmur was not detectable. A left lateral thoracotomy was performed to ligate and transect the PDA without complication. The dog was discharged with mild aspiration pneumonia which resolved with antimicrobial therapy. Twelve months post-surgery the owners reported no regurgitation.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Dogs , Animals , Female , Ductus Arteriosus, Patent/complications , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Echocardiography/veterinary , Tomography, X-Ray Computed , Dog Diseases/diagnostic imaging , Dog Diseases/surgery
14.
J Am Vet Med Assoc ; 261(8): 1-7, 2023 08 01.
Article in English | MEDLINE | ID: mdl-36977484

ABSTRACT

OBJECTIVE: To evaluate the short- and long-term outcomes of dogs undergoing surgical ligation for a left-to-right shunting patent ductus arteriosus (PDA), identify risk factors for intraoperative hemorrhage and intra- and postoperative complications, and report overall mortality rates. ANIMALS: 417 client-owned dogs undergoing surgical ligation for a left-to-right shunting PDA between January 2010 and January 2020. PROCEDURES: Data recorded included patient signalment, echocardiogram findings, intraoperative complications and mortality, postoperative complications, and short- and long-term outcomes. RESULTS: There was no association between age and risk of intraoperative hemorrhage (P = .7), weight and intraoperative hemorrhage (P = .96), or increasing left atrium-to-aortic (LA:Ao) ratio and intraoperative hemorrhage (P = .08). Intraoperative hemorrhage occurred in 10.8% of patients. Intraoperative mortality was 2%. Ninety-five percent of dogs experiencing intraoperative hemorrhage survived to discharge. Survival to discharge was 97%. One- and 5-year survival rates were 96.4% and 87%, respectively. CLINICAL RELEVANCE: Surgical ligation for a left-to-right shunting PDA is recommended due to the good long-term prognosis. Certain preoperative factors such as age, weight, and the presence and degree of mitral valve regurgitation had no detectable association with risks of intraoperative hemorrhage and, therefore, should not preclude surgical treatment for a left-to-right shunting PDA. Future studies are needed to further assess the association between increasing LA:Ao ratio and risk of intraoperative hemorrhage.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Dogs , Animals , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Ligation/veterinary , Postoperative Complications/veterinary , Risk Factors , Hemorrhage/veterinary , Retrospective Studies , Dog Diseases/surgery
15.
Vet Res Commun ; 47(3): 1735-1739, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36633757

ABSTRACT

In the typical left-to-right patent ductus arteriosus (PDA), the shunt flows from the ductus arteriosus towards the pulmonary valve. Although hemodynamic changes have been carefully studied in dogs with PDA, there is very little information on the outcomes of the pulmonary valve after surgical correction of PDA. This study aimed to visualize the pulmonary valve by transthoracic echocardiography in dogs with PDA before and after surgical ligation. Prior to surgery, the movement of the anterior semilunar cusp of the pulmonary valve was obstructed by the shunted blood flow during systole in all nine dogs with PDA in this study. M-mode echocardiography revealed a continuous trajectory of the cusp, because the cusp was pushed towards the right ventricle during the whole cardiac cycle by the shunted flow. Epicardial echocardiography performed in one dog during surgical ligation of the ductus arteriosus revealed that the movement of the anterior semilunar cusp normalized immediately after ligation. B- and M-mode echocardiography may be used to support the diagnosis of PDA through observation of the pulmonary valve when color Doppler echography is not available. The findings in this study may be of importance in distinguishing PDA from PDA-mimicking diseases worth considering before the treatment process (e.g. aorticopulmonary fistulas or aberrant arteriovenous shunts).


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Dyskinesias , Pulmonary Valve , Dogs , Animals , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Pulmonary Valve/diagnostic imaging , Echocardiography/veterinary , Systole , Dyskinesias/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/surgery
16.
J Vet Cardiol ; 45: 41-49, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36696791

ABSTRACT

INTRODUCTIONS: Patient size is a limiting factor for transesophageal echocardiography (TEE) in small dogs. The objective of this study was to describe imaging capabilities of two probes for TEE in small dogs. ANIMALS, MATERIALS, AND METHODS: Prospective study in 10 client-owned dogs weighing <4 kg with congenital heart disease (CHD). Dogs had TEE performed with a microprobe (10T-D, GE Medical) and intracardiac echocardiography (ICE) catheter-based probe (AcuNav™, Biosense Webster) in the esophagus in alternating order. Ease of placement, ability to acquire images of the CHD, image quality, and probe limitations were recorded. RESULTS: Median weight was 2.4 kg (range, 1.0-3.2). Congenital abnormalities included patent ductus arteriosus (n = 9) and pulmonary valve stenosis (n = 1). The 10T-D microprobe was easy to place (n = 8) or achievable with gentle manipulation (n = 2), and image quality of the CHD was optimal (n = 8), adequate (n = 1), or poor (n = 1). The ICE probe was difficult to place in the esophagus even with an external support system (n = 9) or could not be placed (n = 1), and image quality of the CHD was optimal (n = 2), adequate (n = 3), or poor (n = 5). Both probes provided images in a 1.0-kg dog. Probe limitations included lack of lateral motion (microprobe), the need for an external support system (ICE probe) and inability to consistently maintain contact with the esophagus (ICE probe). CONCLUSION: The 10T-D microprobe provided high-quality TEE images more consistently than the ICE probe in the majority of dogs in this study; however, the lack of lateral motion can diminish its utility in some dogs.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Dogs , Animals , Echocardiography, Transesophageal/veterinary , Echocardiography, Transesophageal/methods , Prospective Studies , Dog Diseases/diagnostic imaging , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/veterinary , Cardiac Catheterization/veterinary
17.
Vet Med Sci ; 9(3): 1044-1052, 2023 05.
Article in English | MEDLINE | ID: mdl-36716384

ABSTRACT

Two Maltese dogs were referred for evaluation of a congenital heart disease: one was diagnosed with patent ductus arteriosus and the other was diagnosed with a ventricular septal defect. The PDA patient was diagnosed with congenital heart disease 2 weeks ago and the VSD patient about 11 months ago at another hospital. Echocardiographic findings revealed a bidirectional shunt condition, and the dogs were treated with medical management using sildenafil and oxygen inhalation. After medical management, the dogs returned to clinically normal conditions, and echocardiographic findings revealed a return to left-to-right shunt tendency. These dogs had no clinical signs associated with heart disease 3 years after treatment. This case report describes changes in echocardiography findings according to the progression of the reverse shunt and the possibility of improvement to a left-to-right shunt after medical treatment.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Heart Defects, Congenital , Heart Septal Defects, Ventricular , Dogs , Animals , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/drug therapy , Ductus Arteriosus, Patent/veterinary , Heart Defects, Congenital/veterinary , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/veterinary , Echocardiography/veterinary , Heart , Dog Diseases/diagnostic imaging , Dog Diseases/drug therapy
18.
J Vet Cardiol ; 44: 13-17, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36242857

ABSTRACT

Two Pomeranian dogs referred for interventional correction of a left-to-right shunting patent ductus arteriosus (PDA) had inadequate femoral arterial access for any occlusion device other than micro coils. The decision was made to attempt correction of the PDA using the Amplatzer™ Vascular Plug 4 (AVP4) from a femoral venous approach. An AVP4 was successfully deployed in each dog with complete occlusion noted within 5 min. Complete occlusion was persistent at 24 h after the procedure, while both dogs were subclinical, had no residual ductal flow, and complete or near complete reverse cardiac remodeling at subsequent visits. This report demonstrates the feasibility of PDA occlusion with the AVP4 from the femoral venous approach in small dogs where femoral arterial access is inadequate for other occlusion devices.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Embolization, Therapeutic , Dogs , Animals , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Embolization, Therapeutic/veterinary , Treatment Outcome , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Cardiac Catheterization/veterinary
19.
J Vet Cardiol ; 43: 27-40, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35947914

ABSTRACT

OBJECTIVES: The objectives of this study were to determine whether conducting a clinical audit was achievable in a group of centres that perform interventional cardiac procedures and to report the success and complications rates in dogs diagnosed with patent ductus arteriosus. METHODS: This was a multicentre, European-wide, prospective study. Patient data were entered into a bespoke database prior to commencing interventional closure of patent ductus arteriosus in all animals undergoing this procedure during the study period. The database was designed to gather clinical audit information, after completion of the procedure, such as discharge outcome, complication rate, and medium-term outcome. RESULTS: A total of 339 cases were included from five participating centres. The process of performing clinical audit was achieved in all centres. Successful discharge outcome was 95.9% with a complication rate of 4.1%. The procedure-related mortality was 0.6%. 149 cases (43.9%) were either lost to follow-up or had not yet had a follow-up within the time period. Of the remaining 169 cases in which follow-up was available, 157 (92.9%) cases had a successful medium-term outcome CONCLUSIONS: This study demonstrates that the process of performing a clinical audit is achievable in veterinary clinical interventions across different centres. These results provide a benchmark for future comparison in our ongoing clinical audit and validate the process of clinical audit for other centres performing cardiac interventions. The use of clinical audit should be considered in other aspects of veterinary medicine.


Subject(s)
Dog Diseases , Ductus Arteriosus, Patent , Septal Occluder Device , Dogs , Animals , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Prospective Studies , Treatment Outcome , Clinical Audit , Cardiac Catheterization/methods , Cardiac Catheterization/veterinary , Dog Diseases/surgery
20.
Can Vet J ; 63(7): 706-710, 2022 07.
Article in English | MEDLINE | ID: mdl-35784772

ABSTRACT

A two-week-old female llama cria was brought to the UC Davis Large Animal Hospital for evaluation of a cardiac murmur and suspected syncopal episodes. A grade IV/VI left basilar continuous murmur was present on cardiac auscultation. Echocardiography revealed a left-to-right shunting patent ductus arteriosus (PDA), mild left ventricular enlargement, scant pericardial effusion, and a suspected persistent left cranial vena cava. The PDA was successfully closed with an Amplatz canine duct occluder. Mild mitral regurgitation was present on echocardiography performed 7 d following PDA occlusion. No syncopal episodes were observed in hospital prior to or following PDA occlusion. At approximately 1 mo following PDA closure, a grade I/VI left apical systolic murmur was present and the cria's body condition was improved. Key clinical message: Patent ductus arteriosus closure is achievable in New World camelids using interventional cardiology which provides a minimally invasive treatment option for valuable or companion animals. Since interventional cardiac catheterization is commonly performed in small animal species, veterinary cardiologists are well-equipped to apply these skills to camelids.


Fermeture d'un canal artériel persistant chez un lama cria âgé de 2 semaines à l'aide d'un obturateur de conduit canin Amplatz. Une femelle lama cria âgée de deux semaines a été amenée à l'UC Davis Large Animal Hospital pour l'évaluation d'un souffle cardiaque et d'épisodes syncopaux suspectés. Un souffle continu basilaire gauche de grade IV/VI était présent à l'auscultation cardiaque. L'échocardiographie a révélé une persistance du canal artériel avec perméabilité de gauche à droite (PDA), une légère hypertrophie ventriculaire gauche, un léger épanchement péricardique et une suspicion de veine cave crâniale gauche persistante. Le PDA a été fermé avec succès avec un obturateur de conduit canin Amplatz. Une régurgitation mitrale légère était présente sur l'échocardiographie réalisée 7 jours après l'occlusion du PDA. Aucun épisode de syncope n'a été observé à l'hôpital avant ou après l'occlusion du PDA. Environ 1 mois après la fermeture du PDA, un souffle systolique apical gauche de grade I/VI était présent et l'état corporel du cria s'était amélioré.Message clinique clé :La fermeture brevetée du canal artériel est réalisable chez les camélidés du Nouveau Monde en utilisant la cardiologie interventionnelle qui offre une option de traitement peu invasive pour les animaux de valeur ou de compagnie. Étant donné que le cathétérisme cardiaque interventionnel est couramment pratiqué chez les petites espèces animales, les cardiologues vétérinaires sont bien équipés pour appliquer ces compétences aux camélidés.(Traduit par Dr Serge Messier).


Subject(s)
Camelids, New World , Dog Diseases , Ductus Arteriosus, Patent , Animals , Dog Diseases/surgery , Dogs , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/veterinary , Echocardiography/veterinary , Female
SELECTION OF CITATIONS
SEARCH DETAIL
...