Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.109
Filter
1.
Environ Geochem Health ; 46(6): 201, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696114

ABSTRACT

The study's objective was to determine the air quality in an asbestos-related industry and its impact on current workers' respiratory health. Seventy-seven air and 65 dust samples were collected at 5-day intervals in an asbestos roofing sheets production factory in Sri Lanka having two production facilities. Sampling was performed in ten sites: Defective sheets-storage, Production-plant, Pulverizer, Cement-silo, and Loading-area. A detailed questionnaire and medical screening were conducted on 264 workers, including Lung Function Tests (LFT) and chest X-rays. Asbestos fibres were observed in deposited dust samples collected from seven sites. Free chrysotile fibres were absent in the breathing air samples. Scanning Electron Microscopy confirmed the presence of asbestos fibres, and the Energy Dispersive X-ray analysis revealed Mg, O, and Si in depositions. The average concentrations of trace metals were Cd-2.74, Pb-17.18, Ni-46.68, Cr-81.01, As-7.12, Co-6.77, and Cu-43.04 mg/kg. The average Zn, Al, Mg, and Fe concentrations were within 0.2-163 g/kg. The highest concentrations of PM2.52.5 and PM1010, 258 and 387 µg/m3, respectively, were observed in the Pulverizer site. Forty-four workers had respiratory symptoms, 64 presented LFT abnormalities, 5 indicated chest irregularities, 35.98% were smokers, and 37.5% of workers with abnormal LFT results were smokers. The correlation coefficients between LFT results and work duration with respiratory symptoms and work duration and chest X-ray results were 0.022 and 0.011, respectively. In conclusion, most pulmonary disorders observed cannot directly correlate to Asbestos exposure due to negligible fibres in breathing air, but fibres in the depositions and dust can influence the pulmonary health of the employees.


Subject(s)
Asbestos , Occupational Exposure , Humans , Sri Lanka , Occupational Exposure/analysis , Asbestos/analysis , Male , Middle Aged , Adult , Air Pollutants, Occupational/analysis , Dust/analysis , Respiratory Function Tests , Environmental Monitoring/methods , Female , Manufacturing Industry
2.
Environ Microbiol Rep ; 16(3): e13265, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38747207

ABSTRACT

Role of dust in Salmonella transmission on chicken farms is not well characterised. Salmonella Typhimurium (ST) infection of commercial layer chickens was investigated using a novel sprinkling method of chicken dust spiked with ST and the uptake compared to a conventional oral infection. While both inoculation methods resulted in colonisation of the intestines, the Salmonella load in liver samples was significantly higher at 7 dpi after exposing chicks to sprinkled dust compared to the oral infection group. Infection of chickens using the sprinkling method at a range of doses showed a threshold for colonisation of the gut and organs as low as 1000 CFU/g of dust. Caecal content microbiota analysis post-challenge showed that the profiles of chickens infected by the sprinkling and oral routes were not significantly different; however, both challenges induced differences when compared to the uninfected negative controls. Overall, the study showed that dust sprinkling was an effective way to experimentally colonise chickens with Salmonella and alter the gut microbiota than oral gavage at levels as low as 1000 CFU/g dust. This infection model mimics the field scenario of Salmonella infection in poultry sheds. The model can be used for future challenge studies for effective Salmonella control.


Subject(s)
Chickens , Dust , Gastrointestinal Microbiome , Poultry Diseases , Salmonella Infections, Animal , Salmonella typhimurium , Animals , Chickens/microbiology , Salmonella typhimurium/growth & development , Dust/analysis , Salmonella Infections, Animal/microbiology , Salmonella Infections, Animal/prevention & control , Poultry Diseases/microbiology , Poultry Diseases/prevention & control , Cecum/microbiology , Liver/microbiology
3.
Environ Int ; 187: 108697, 2024 May.
Article in English | MEDLINE | ID: mdl-38696979

ABSTRACT

Road dust is a demonstrated source of urban air pollution. Given this, the implementation of street sweeping strategies that effectively limit road dust accumulation and resuspension should be a public health priority. Research examining the effectiveness of street sweeping for road dust removal in support of good air quality has been limited to date. To address this, the study aimed to assess the use of a regenerative-air street sweeper to efficiently remove road dust particles and metal(loid)s in size fractions relevant for respiratory exposure in Toronto, Canada. As part of this, the mass amounts, particle size distribution and elemental concentrations of bulk road dust before and after sweeping at five arterial sites were characterized. Sweeping reduced the total mass amount of thoracic-sized (<10 µm) road dust particles by 76 % on average. A shift in the size distribution of remaining particles toward finer fractions was observed in post-sweeping samples, together with an enrichment in many metal(loid)s such as Co, Ti and S. Overall, the mass amounts of metal(loid)s of respiratory health concern like Cu and Zn were greatly reduced with sweeping. Traffic volume and road surface quality were predictors of dust loadings and elemental concentrations. Road surface quality was also found to impact street sweeping efficiencies, with larger mass amounts per unit area collected post-sweeping where street surfaces were distressed. This study demonstrates that street sweeping using advanced technology can be highly effective for road dust removal, highlighting its potential to support air quality improvement efforts. The importance of tailoring sweeping service levels and technologies locally as per the quality of road surface and traffic patterns is emphasized. Continued efforts to mitigate non-exhaust emissions that pose a respiratory health risk at their source is essential.


Subject(s)
Air Pollutants , Dust , Metals , Particle Size , Dust/analysis , Air Pollutants/analysis , Metals/analysis , Air Pollution/prevention & control , Cities , Environmental Monitoring/methods , Humans , Particulate Matter/analysis , Vehicle Emissions/analysis
4.
Environ Int ; 187: 108708, 2024 May.
Article in English | MEDLINE | ID: mdl-38703447

ABSTRACT

Long-term exposure to urban dust containing potentially toxic elements (PTEs) poses detrimental impacts on human health. However, studies estimating human health risks in urban dusts from a global perspective are scarce. We evaluated data for twelve PTEs in urban dusts across 59 countries from 463 published articles, including their concentrations, input sources, and probabilistic risks to human health. We found that 34.1 and 60.3% of those investigated urban dusts have been heavily contaminated with As and Cd, respectively. The input of PTEs was significantly correlated with economic structure due to emissions of industrial activities and traffic emissions being the major sources. Based on the Monte Carlo simulation, we found that the mean hazard index below the safe threshold (1.0) could still cause non-negligible risks to human health. Arsenic and Cr were the major PTEs threatening human health, and relatively high risk levels were observed in cities in China, Korea, Chile, Malaysia, and Australia. Importantly, our analysis suggested that PTEs threaten the health of approximately 92 million adults and 280 million children worldwide. Overall, our study provides important foundational understanding and guidance for policy decision-making to reduce the potential risks associated with PTE exposure and to promote sustainable development of urban economies.


Subject(s)
Cities , Dust , Environmental Exposure , Dust/analysis , Humans , Risk Assessment , Environmental Exposure/statistics & numerical data , Air Pollutants/analysis , Environmental Monitoring , Arsenic/analysis , China , Hazardous Substances/analysis
5.
Sci Total Environ ; 932: 173031, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38723961

ABSTRACT

The widespread extensive use of synthetic polymers has led to a substantial environmental crisis caused by plastic pollution, with microplastics detected in various environments and posing risks to both human health and ecosystems. The possibility of plastic fragments to be dispersed in the air as particles and inhaled by humans may cause damage to the respiratory and other body systems. Therefore, there is a particular need to study microplastics as air pollutants. In this study, we tested a combination of analytical pyrolysis, gas chromatography-mass spectrometry, and gas and liquid chromatography-mass spectrometry to identify and quantify both microplastics and their additives in airborne particulate matter and settled dust within a workplace environment: a WEEE treatment plant. Using this combined approach, we were able to accurately quantify ten synthetic polymers and eight classes of polymer additives. The identified additives include phthalates, adipates, citrates, sebacates, trimellitates, benzoates, organophosphates, and newly developed brominated flame retardants.


Subject(s)
Air Pollutants , Environmental Monitoring , Microplastics , Particulate Matter , Plastics , Polymers , Microplastics/analysis , Polymers/analysis , Environmental Monitoring/methods , Particulate Matter/analysis , Air Pollutants/analysis , Plastics/analysis , Gas Chromatography-Mass Spectrometry , Humans , Flame Retardants/analysis , Dust/analysis
7.
Sci Rep ; 14(1): 11858, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789478

ABSTRACT

Human occupied built environments are no longer confined to Earth. In fact, there have been humans living and working in low-Earth orbit on the International Space Station (ISS) since November 2000. With NASA's Artemis missions and the age of commercial space stations set to begin, more human-occupied spacecraft than ever will be in Earth's orbit and beyond. On Earth and in the ISS, microbes, especially fungi, can be found in dust and grow when unexpected, elevated moisture conditions occur. However, we do not yet know how indoor microbiomes in Earth-based homes and in the ISS differ due to their unique set of environmental conditions. Here we show that bacterial and fungal communities are different in dust collected from vacuum bags on Earth and the ISS, with Earth-based homes being more diverse (465 fungal OTUs and 237 bacterial ASVs) compared to the ISS (102 fungal OTUs and 102 bacterial ASVs). When dust from these locations were exposed to varying equilibrium relative humidity conditions (ERH), there were also significant fungal community composition changes as ERH and time elevated increased (Bray Curtis: R2 = 0.35, P = 0.001). These findings can inform future spacecraft design to promote healthy indoor microbiomes that support crew health, spacecraft integrity, and planetary protection.


Subject(s)
Air Pollution, Indoor , Dust , Fungi , Microbiota , Spacecraft , Dust/analysis , Fungi/isolation & purification , Fungi/classification , Humans , Air Pollution, Indoor/analysis , Built Environment , Bacteria/classification , Bacteria/isolation & purification , Bacteria/genetics , Air Microbiology , Earth, Planet , Humidity
8.
Environ Sci Pollut Res Int ; 31(24): 35429-35441, 2024 May.
Article in English | MEDLINE | ID: mdl-38727973

ABSTRACT

An extensive analysis of the distribution patterns of three distinct classes of semi-volatile organic chemicals (SVOCs)-phthalates (PAEs), organophosphate flame retardants (OPFRs), and polycyclic aromatic hydrocarbons (PAHs)-across four distinct size fractions of dust (25, 50, 100, and 200 µm) was conducted. The dust samples were sourced from AC filter, covered car parking lots, households, hotels, mosques, and car floors. To generate the four fractions, ten dust samples from each microenvironment were pooled and sieved utilizing sieving apparatus with the appropriate mesh size. Selected SVOCs were quantified utilizing gas chromatography-mass spectrometry in electron impact (EI) mode. Results unveiled diverse contamination levels among dust fractions, showcasing car parking lot dust with the lowest chemical contamination, while car floor dust displayed the highest levels of PAHs and OPFRs, peaking at 28.3 µg/g and 43.2 µg/g, respectively. In contrast, mosque and household floor dust exhibited the highest concentrations of phthalates, with values of 985 µg/g and 846 µg/g, respectively. Across the analyzed microenvironments, we observed a trend where concentrations of SVOCs tended to rise as dust particles decreased in size, forming a visually striking pattern. This phenomenon was particularly pronounced in dust samples collected from car floors and parking lots. Among SVOCs, PAEs emerged as the predominant contributors with > 90% followed by OPFRs and PAHs. The high levels of OPFRs in car floor dust align logically with the fact that numerous interior components of cars are treated with OPFRs, within a compact indoor microenvironment, to comply to fire safety regulations. Furthermore, petroleum products are a major source of PAHs in the environment and all the sampled cars in the study had combustion engines. Consequently, car dust is more likely to be polluted with PAHs stemming from petroleum combustion. Although previous investigations have noted an increase in heavy metals and brominated flame retardants with decreasing dust particles, this is the first study analyzing these SVOCs in different fractions of dust from various microenvironments. However, aside from two specific microenvironments, the observed pattern of escalating SVOC concentrations with smaller dust particle sizes was not corroborated among the examined microenvironments. This divergence in concentration trends suggests the potential involvement of supplementary variables in influencing SVOC distributions within dust particles.


Subject(s)
Air Pollution, Indoor , Dust , Environmental Monitoring , Particle Size , Polycyclic Aromatic Hydrocarbons , Volatile Organic Compounds , Dust/analysis , Volatile Organic Compounds/analysis , Air Pollution, Indoor/analysis , Polycyclic Aromatic Hydrocarbons/analysis , Flame Retardants/analysis , Air Pollutants/analysis
9.
J Hazard Mater ; 472: 134359, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38691990

ABSTRACT

Microplastics (MPs) are an emerging global concern due to severe toxicological risks for ecosystems and public health. Therefore, this is the first study in Bangladesh to assess MP pollution and its associated risks for ecosystems and human health in the outdoor urban environment using machine learning and multivariate approaches. The occurrences of MPs in the urban road dust were 52.76 ± 20.24 particles/g with high diversity, where fiber shape (77%), 0.1-0.5 mm size MPs (75%), blue color (26%), and low-density polyethylene (24%) polymer was the dominating MPs category. Pollution load index value (1.28-4.42), showed severe pollution by MPs. Additionally, the contamination factor (1.00-5.02), and Nemerow pollution index (1.38-5.02), indicate moderate to severe MP pollution. The identified polymers based on calculated potential ecological risk (2248.52 ± 1792.79) and polymer hazard index (814.04 ± 346.15) showed very high and high risks, respectively. The occurrences of MPs could effectively be predicted by random forest, and support random vector machine, where EC, salinity, pH, OC, and texture classes were the influencing parameters. Considering the human health aspect, children and adults could be acutely exposed to 19259.68 and 5777.90 MP particles/ year via oral ingestion. Monte-Carlo-based polymers associated cancer risk assessment results indicate moderate risk and high risk for adults and children, respectively, where children were more vulnerable than adults for MP pollution risks. Overall assessment mentioned that Dhaka was the most polluted division among the other divisions.


Subject(s)
Environmental Monitoring , Machine Learning , Microplastics , Bangladesh , Microplastics/analysis , Microplastics/toxicity , Risk Assessment , Environmental Monitoring/methods , Humans , Environmental Pollution/analysis , Cities , Multivariate Analysis , Dust/analysis
10.
Environ Sci Technol ; 58(21): 9339-9349, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38748567

ABSTRACT

Residential lead (Pb) exposure is of critical concern to families globally as Pb promotes severe neurological effects in children, especially those less than 5 years old, and no blood lead level is deemed safe by the US Center for Disease Control. House dust and soils are commonly thought to be important sources of Pb exposure. Probing the relationship between house dust and soil Pb is critical to understanding residential exposure, as Pb bioavailability is highly influenced by Pb sources and/or species. We investigated paired house dust and soil collected from homes built before 1978 to determine Pb speciation, source, and bioaccessibility with the primary goal of assessing chemical factors driving Pb exposure in residential media. House dust was predominately found to contain (hydro)cerussite (i.e., Pb (hydroxy)carbonate) phases commonly used in Pb-based paint that, in-turn, promoted elevated bioaccessibility (>60%). Pb X-ray absorption spectroscopy, µ-XRF mapping, and Pb isotope ratio analysis for house dust and soils support house dust Pb as chemically unique compared to exterior soils, although paint Pb is expected to be a major source for both. Soil pedogenesis and increased protection from environmental conditions (e.g., weathering) in households is expected to greatly impact Pb phase differences between house dust and soils, subsequently dictating differences in Pb exposure.


Subject(s)
Dust , Lead , Soil Pollutants , Soil , Dust/analysis , Lead/analysis , Soil Pollutants/analysis , United States , Soil/chemistry , Housing , Humans , Environmental Monitoring
11.
Nature ; 629(8012): 603-608, 2024 May.
Article in English | MEDLINE | ID: mdl-38750234

ABSTRACT

Natural iron fertilization of the Southern Ocean by windblown dust has been suggested to enhance biological productivity and modulate the climate1-3. Yet, this process has never been quantified across the Southern Ocean and at annual timescales4,5. Here we combined 11 years of nitrate observations from autonomous biogeochemical ocean profiling floats with a Southern Hemisphere dust simulation to empirically derive the relationship between dust-iron deposition and annual net community production (ANCP) in the iron-limited Southern Ocean. Using this relationship, we determined the biological response to dust-iron in the pelagic perennially ice-free Southern Ocean at present and during the last glacial maximum (LGM). We estimate that dust-iron now supports 33% ± 15% of Southern Ocean ANCP. During the LGM, when dust deposition was 5-40-fold higher than today, the contribution of dust to Southern Ocean ANCP was much greater, estimated at 64% ± 13%. We provide quantitative evidence of basin-wide dust-iron fertilization of the Southern Ocean and the potential magnitude of its impact on glacial-interglacial timescales, supporting the idea of the important role of dust in the global carbon cycle and climate6-8.


Subject(s)
Carbon Cycle , Climate , Dust , Iron , Oceans and Seas , Seawater , Dust/analysis , Ice Cover , Iron/analysis , Nitrates/analysis , Seawater/chemistry
12.
Int J Circumpolar Health ; 83(1): 2343125, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38626426

ABSTRACT

Arctic miners face significant risks from diesel exhaust and dust exposure, potentially leading to adverse respiratory health. Employers must limit harmful exposures, using personal protective equipment (PPE) as a last line of defense. This study explored the association between reported respiratory exposure and symptoms, and PPE training and usage. Data from the MineHealth study (2012-2014) included a total of 453 Arctic open pit miners in Norway, Sweden, and Finland. Participants answered questions on exposure to dust and diesel exhaust, respiratory symptoms, and PPE use, in addition to age, gender, BMI, smoking, and self-rated health. Estimated exposure to dust was common, reported by 91%, 80%, and 82% and that of diesel exhaust by 84%, 43%, and 47% of workers in Sweden, Finland, and Norway, respectively. Reported dust exposure was significantly related to respiratory symptoms (OR 2.2, 95% CI 1.3-3.7), diesel exposure increased the occurrence of wheezing (OR 2.6, 95% CI 1.3-5.4). PPE use varied between the studied mines. Non-use was common and related to reduced visibility, wetness, skin irritation and fogging of the respiratory PPE. Future research should employ more precise exposure assessment, respiratory function as well as explore the reasons behind the non-compliance of PPE use.


Subject(s)
Air Pollutants, Occupational , Lung Diseases , Occupational Exposure , Humans , Dust/analysis , Vehicle Emissions/analysis , Occupational Exposure/adverse effects , Air Pollutants, Occupational/analysis , Self Report , Protective Devices
13.
Environ Int ; 186: 108610, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38626495

ABSTRACT

Greater Cairo, the largest megacity of the Middle East North Africa (MENA) region, is currently suffering from major aerosol pollution, posing a significant threat to public health. However, the main sources of pollution remain insufficiently characterized due to limited atmospheric observations. To bridge this knowledge gap, we conducted a continuous 2-month field study during the winter of 2019-2020 at an urban background site, documenting for the first time the chemical and physical properties of submicron (PM1) aerosols. Crustal material from both desert dust and road traffic dust resuspension contributed as much as 24 % of the total PM1 mass (rising to 66 % during desert dust events), a figure not commonly observed in urban environments. Our observations showed significant decreases in black carbon concentrations and ammonium sulfate compared to data from 15 years ago, indicating an important reduction in both local and regional emissions as a result of effective mitigation measures. The diurnal variability of carbonaceous aerosols was attributed to emissions emanating from local traffic at rush hours and nighttime open biomass burning. Surprisingly, semi-volatile ammonium chloride (NH4Cl) originating from local open biomass and waste burning was found to be the main chemical species in PM1 over Cairo. Its nighttime formation contributed to aerosol water uptake during morning hours, thereby playing a major role in the build-up of urban haze. While our results confirm the persistence of a significant dust reservoir over Cairo, they also unveil an additional source of highly hygroscopic (semi-volatile) inorganic salts, leading to a unique type of urban haze. This haze, with dominant contributors present in both submicron (primarily as NH4Cl) and supermicron (largely as dust) modes, underscores the potential implications of heterogeneous chemical transformation of air pollutants in urban environments.


Subject(s)
Aerosols , Air Pollutants , Air Pollution , Environmental Monitoring , Particulate Matter , Aerosols/analysis , Air Pollutants/analysis , Egypt , Air Pollution/statistics & numerical data , Particulate Matter/analysis , Cities , Dust/analysis , Particle Size
14.
Front Public Health ; 12: 1339755, 2024.
Article in English | MEDLINE | ID: mdl-38577275

ABSTRACT

Background: It has been reported that the disease-initiated and disease-mediated effects of aerosol pollutants can be related to concentration, site of deposition, duration of exposure, as well as the specific chemical composition of pollutants. Objectives: To investigate the microelemental composition of dust aggregates in primary schools of Vilnius and determine trace elements related to acute upper respiratory infections among 6-to 11-year-old children. Methods: Microelemental analysis of aerosol pollution was performed using dust samples collected in the classrooms of 11 primary schools in Vilnius from 2016 to 2020. Sites included areas of its natural accumulation behind the radiator heaters and from the surface of high cupboards. The concentrations of heavy metals (Pb, W, Sb, Sn, Zr, Zn, Cu, Ni, Mn, Cr, V, and As) in dust samples were analyzed using a SPECTRO XEPOS spectrometer. The annual incidence rates of respiratory diseases in children of each school were calculated based on data from medical records. Results: The mean annual incidence of physician-diagnosed acute upper respiratory infections (J00-J06 according to ICD-10A) among younger school-age children was between 25.1 and 71.3% per school. A significant correlation was found between vanadium concentration and the number of episodes of acute upper respiratory infections during each study year from 2016 to 2020. The lowest was r = 0.67 (p = 0.024), and the highest was r = 0.82 (p = 0.002). The concentration of vanadium in the samples of dust aggregates varied from 12.7 to 52.1 parts per million (ppm). No significant correlations between the other trace elements and the incidence of upper respiratory infections were found, which could be caused by a small number of study schools and relatively low concentrations of other heavy metals found in the samples of indoor dust aggregates. Conclusion: A significant and replicable correlation was found between the concentration of vanadium in the samples of natural dust aggregates collected in primary schools and the incidence of acute upper respiratory infections in children. Monitoring the concentration of heavy metals in the indoor environment can be an important instrument for the prevention and control of respiratory morbidity in children.


Subject(s)
Environmental Pollutants , Metals, Heavy , Respiratory Tract Infections , Trace Elements , Child , Humans , Dust/analysis , Vanadium/analysis , Incidence , Environmental Monitoring , Trace Elements/analysis , Respiratory Aerosols and Droplets , Metals, Heavy/analysis , Environmental Pollutants/analysis , Respiratory Tract Infections/epidemiology
15.
Environ Monit Assess ; 196(5): 481, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38683240

ABSTRACT

The continuous expansion of the global vehicle fleet poses a growing threat to environmental quality through heavy metal contamination. In this scenario, monitoring to safeguard public health in urban areas is necessary. Our study involved the collection of 36 street dust and 29 moss samples from roads of a Brazilian metropolis (Recife) with varying traffic intensities as follows: natural reserve (0 vehicles per day), low (< 15,000 vehicles per day), medium (15,000-30,000 vehicles per day), and high (> 30,000 vehicles per day). ICP-AES analysis was performed to determine the concentrations of nine potentially toxic metals (Ba, Cd, Cr, Cu, Mn, Ni, Pb, V, and Zn) to assess the influence of vehicular flow on urban contamination. In the street dust samples, the mean metal concentrations (mg kg-1) exhibited the following order: Ba (503.7) > Mn (303.0) > Zn (144.4) > Cu (95.3) > Cr (56.1) > Pb (34.2) > V (28.7) > Ni (11.3) > Cd (1.5). Conversely, in the moss samples, the metal concentration order was as follows (mg kg-1): Mn (63.8) > Zn (62.5) > Ba (61.0) > Cu (17.7) > Cr (8.0) > V (7.3) > Pb (7.0) > Ni (2.9) > Cd (0.3). Roads with higher traffic volumes exhibited the highest metal enrichments in moss samples for all metals and in dust samples for Cd, Cr, Mn, Ni, and V. However, dust from low-flow roads had higher enrichments for Ba, Cu, and Zn, indicating the influential role of other traffic-related factors in metal deposition. Our findings highlight traffic flow as the predominant source of pollution in urban centers, with both street dust and moss serving as sensitive indicators of metal input attributable to vehicular traffic. These indicators offer valuable insights for urban quality monitoring and pollution control efforts.


Subject(s)
Cities , Dust , Environmental Monitoring , Metals, Heavy , Metals, Heavy/analysis , Brazil , Environmental Monitoring/methods , Dust/analysis , Environmental Pollutants/analysis , Vehicle Emissions/analysis , Air Pollutants/analysis
16.
Environ Monit Assess ; 196(5): 484, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38684530

ABSTRACT

The present study focuses on the elemental analysis of road dust in Guwahati, the largest city of Assam and the largest metropolis of Northeast India during the Diwali festival. Road dust samples were collected on pre-Diwali (PD), the Day after Diwali (DaD), and one week after Diwali (WaD) from two sites (Lankeshwar; LKW and Patharquarry; PTQ). Three composite samples were collected from 3 points at each site. The elemental concentration was analyzed using inductively coupled plasma mass spectrometry (ICP-MS). The concentrations of Ba and Sr increased by 1.6 and 1.7 times, respectively, after Diwali. Among other firework-related elements (FREs), Mg, Al, K, and Cu increased at LKW following Diwali (both DaD and WaD), whereas Mg, Al, and K increased in DaD dust at PTQ. The average concentration of Traffic Related Elements (TREs) at PTQ was significantly higher than at LKW (p < 0.05; 75.40 mg/kg vs 63.96 mg/kg). Cd had the highest enrichment (EF), followed by Ni and Zn. EF for Cd, Ni, and Zn ranged from high to extremely high enrichment. Ni and Cd exhibited moderate contamination (CF). The ecological risk (ER) values for Cd at LKW and PTQ were 54.32 and 56.71, respectively, indicating a moderate ER. Pearson's correlation was performed to study the relationship between elements, while PCA analysis was used to identify the main sources of these elements. Although the health hazard indices presently do not suggest any immediate danger, hazard quotient (HQ) values for ingestion, inhalation, and dermal exposure were higher for children than adults. In children, the contribution of HQing to HI (total risk) was the highest, accounting for more than 65% of all elements. There is no apparent lifetime cancer risk due to road dust exposure through inhalation.


Subject(s)
Air Pollutants , Cities , Dust , Environmental Monitoring , Dust/analysis , India , Air Pollutants/analysis , Humans , Holidays
17.
Environ Pollut ; 350: 124010, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38648964

ABSTRACT

Microenvironments, such as student dormitories, differ from general residential environments. They are characterized by small spaces, poor air circulation, high personnel densities, and electronic products, such as computers that are turned on for extended periods, leading to increased pollution concentrations. The limited space and poor air circulation reduce migration of contaminants, such as polybrominated diphenyl ethers (PBDEs), making it easier for PBDEs to accumulate. However, few studies have been conducted on small group dwellings, including student dormitory dwellings. We collected dust samples from student dormitories of a university to analyze the characteristics and traceability of PBDEs in dormitory microenvironments. The results showed that PBDE congeners were widely present in university dormitories and the order of median concentration of ∑10PBDEs was as follows: male old-fashioned dormitory (273 ng/g) > female four-person dormitory (132 ng/g) > female two-person dormitory (132 ng/g) > male two-person dormitory (96.2 ng/g) > female old-fashioned dormitory (91.6 ng/g) > male four-person apartment (51.8 ng/g). BDE-209 was the most abundant PBDE congener, followed by BDE-47, and BDE-28. PBDEs were also found in typical electrical appliances, with higher concentrations in laptops than in desktops, and higher concentrations in desktops than in idle ones. According to Spearman correlation and Principal Component Analysis (PCA), we also found that boards and wallpaper materials were common sources of contamination in the microenvironment of student dormitories, and that female dormitories had more sources of PBDE emissions. Human exposure to PBDEs in students is below the US Environmental Protection Agency reference dose. Although exposure to PBDEs generated in dormitories does not pose a significant health risk, the potential hazards of PBDEs to the reagent environment remain to be investigated.


Subject(s)
Air Pollution, Indoor , Environmental Exposure , Environmental Monitoring , Halogenated Diphenyl Ethers , Housing , Students , Halogenated Diphenyl Ethers/analysis , Humans , Female , Male , Environmental Exposure/statistics & numerical data , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Dust/analysis , Universities , Air Pollutants/analysis
18.
Environ Pollut ; 350: 123976, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38657893

ABSTRACT

The lack of knowledge regarding the extent of microbial contamination in Portuguese fitness centers (FC) puts attendees and athletes at risk for bioaerosol exposure. This study intends to characterize microbial contamination in Portuguese FC by passive sampling methods: electrostatic dust collectors (EDC) (N = 39), settled dust (N = 8), vacuum filters (N = 8), and used cleaning mops (N = 12). The obtained extracts were plated in selective culture media for fungi and bacteria. Filters, EDC, and mop samples' extracts were also screened for antifungal resistance and used for the molecular detection of the selected Aspergillus sections. The detection of mycotoxins was conducted using a high-performance liquid chromatograph (HPLC) system and to determine the cytotoxicity of microbial contaminants recovered by passive sampling, HepG2 (human liver carcinoma) and A549 (human alveolar epithelial) cells were employed. The results reinforce the use of passive sampling methods to identify the most critical areas and identify environmental factors that influence microbial contamination, namely having a swimming pool. The cardio fitness area presented the highest median value of total bacteria (TSA: 9.69 × 102 CFU m-2.day-1) and Gram-negative bacteria (VRBA: 1.23 CFU m-2.day-1), while for fungi it was the open space area, with 1.86 × 101 CFU m-2.day-1. Aspergillus sp. was present in EDC and in filters used to collect settled dust. Reduced azole susceptibility was observed in filters and EDC (on ICZ and VCZ), and in mops (on ICZ). Fumonisin B2 was the only mycotoxin detected and it was present in all sampling matrixes except settled dust. High and moderate cytotoxicity was obtained, suggesting that A549 cells were more sensitive to samples' contaminants. The observed widespread of critical toxigenic fungal species with clinical relevance, such as Aspergillus section Fumigati, as well as Fumonisin B2 emphasizes the importance of frequent and effective cleaning procedures while using shared mops appeared as a vehicle of cross-contamination.


Subject(s)
Air Microbiology , Environmental Monitoring , Fungi , Portugal , Humans , Environmental Monitoring/methods , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Mycotoxins/analysis , Dust/analysis , Hep G2 Cells , A549 Cells , Bacteria/isolation & purification
19.
Environ Pollut ; 350: 124023, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38663508

ABSTRACT

Considering that microplastics (MPs) are classified as ubiquitous pollutants, that air quality affects human health, and that people remain indoors most of the time, the need has arisen to evaluate the exposure to MPs within the suspended dust in indoor environments. With this objective, the present study carried out passive sampling to analyze the precipitation of microparticles in some indoor residential environments (2 apartments) and workplaces (an office, a pastry shop, a gift shop, and a paint shop) in Barranquilla, Colombia. The quantification and physical characterization of microparticles were carried out under a stereomicroscope, and the chemical characterization was carried out by infrared microspectroscopy (µFTIR). The highest average concentration of MPs in the apartments was found in the air-conditioned rooms (1.1 × 104 MP/m2/day), and concerning the workplaces, the gift shop and the paint shop were the spaces with a higher proportion of MPs (6.0-6.1 × 103 MP/m2/day), with polyesters being the main synthetic polymers, but being semi-synthetic particles the predominant among the samples. Regarding its morphology, fibers were the most abundant shape (>90%), grouping mainly in the 1000-5000 µm range, while the few fragments found were mostly grouped below 50 µm. Exposure by inhalation of MPs in adults was estimated between 1.7 × 102-1.6 × 103 MP/kg/day, while by ingestion it ranged between 2.7 × 102-2.4 × 103 MPs/kg/day. On the other hand, within our research, a significant presence of non-plastic microparticles was found, which reached up to 69% in analyzed samples, corresponding mainly to cotton and cellulose, so we suggest that these should also be included in future studies that aim to estimate potential health implications from exposure to suspended micropollutants.


Subject(s)
Air Pollution, Indoor , Dust , Environmental Monitoring , Microplastics , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Microplastics/analysis , Colombia , Dust/analysis , Environmental Monitoring/methods , Air Pollutants/analysis , Particle Size , Humans , Particulate Matter/analysis
20.
Water Sci Technol ; 89(8): 1996-2005, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38678404

ABSTRACT

Leaking manhole covers add inflow to sanitary sewer systems. These are the most accessible components of the sewer system, and so potentially the cheapest to repair or modify, to reduce inflow. There is, however, very little data regarding manhole cover leakage available to evaluate the cost-benefit of such an approach, and there is no field data. So, a multi-year field study of inflow was conducted. Two-hundred and fifty manholes in New York City and surrounding towns were tested. A key field observation in this study was that a dust and grit seal typically built up between the cover and the rim. This seal had a big impact on leakage rates. This made testing in-situ a necessity, and the test method had to preserve this seal. Due to the presence of the dust and grit seal, approximately 80% of the manholes tested showed no leakage. A further 15% had slow leaks. Only 5% had significant leaks.


Subject(s)
Dust , New York City , Dust/analysis , Waste Disposal, Fluid/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...